1
|
Musmar B, Salim H, Abdelgadir J, Spellicy S, Adeeb N, Liu J, Jabbour P, Hasan D, Zomorodi A. Balloon-mounting stent versus balloon angioplasty for intracranial arterial stenosis: A systematic review and meta-analysis. J Stroke Cerebrovasc Dis 2024; 33:107631. [PMID: 38331010 DOI: 10.1016/j.jstrokecerebrovasdis.2024.107631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 02/10/2024] Open
Abstract
BACKGROUND Intracranial artery atherosclerotic stenosis (ICAS) is a major cause of stroke, especially in Asian countries. Current treatment options, including balloon-mounted stent (BMS) and balloon angioplasty (BA), lack sufficient evidence to determine a preferred approach. This systematic review and meta-analysis aimed to compare the efficacy and safety of BMS and BA in treating ICAS. METHODS Following PRISMA 2020 guidelines, we conducted a comprehensive search in PubMed, Web of Science, and Scopus up to December 1, 2023. Eligible studies compared BMS with BA in patients diagnosed with ICAS. Primary outcomes included the success rate and occurrence of stroke (ischemic or hemorrhagic). Secondary outcomes were perforator occlusion, in-stent thrombosis, death, and restenosis. Statistical analysis was conducted using R software version 4.3.1, employing a random-effects model. RESULTS Five high-quality studies involving 707 patients (515 males, 192 females) were included. BMS had a significantly higher success rate compared to BA (Risk Ratio [RR]: 1.13; CI: 1.03 to 1.24, p < 0.01; I2 = 14 %). The overall risk for stroke (ischemic and hemorrhagic) was significantly higher in BMS (RR: 2.97; CI: 1.32 to 6.67, p < 0.01; I2 = 0 %). However, no significant difference was found between BMS and BA regarding ischemic stroke (RR: 2.33; CI: 0.80 to 6.74, p = 0.12; I2 = 0 %). Additionally, no significant differences were observed in terms of perforator occlusion, in-stent thrombosis, dissection, minor and major strokes, and mortality rates. BMS was associated with a lower risk of restenosis (RR: 0.31; 95 % CI: 0.12 to 0.83, p = 0.02; I2 = 0 %). CONCLUSION Our results indicate that BMS might be associated with higher success and lower restenosis rates than BA in the treatment of ICAS but with an increased overall risk of stroke. No significant differences were observed in ischemic stroke, perforator occlusion, in-stent thrombosis, dissection, minor and major strokes, and mortality rates. The choice of treatment should consider these findings, alongside the technical challenges and desired angiographic outcomes. Future randomized controlled trials are necessary to further elucidate these results.
Collapse
Affiliation(s)
- Basel Musmar
- Department of Neurosurgery, Duke University Hospital, Durham, NC, USA.
| | - Hamza Salim
- Department of Neurosurgery, Louisiana State University, Shreveport, LA 70803, USA
| | - Jihad Abdelgadir
- Department of Neurosurgery, Duke University Hospital, Durham, NC, USA
| | - Samantha Spellicy
- Department of Neurosurgery, Duke University Hospital, Durham, NC, USA
| | - Nimer Adeeb
- Department of Neurosurgery, Louisiana State University, Shreveport, LA 70803, USA
| | - Jian Liu
- Department of Neurosurgery, Duke University Hospital, Durham, NC, USA
| | - Pascal Jabbour
- Department of Neurosurgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| | - David Hasan
- Department of Neurosurgery, Duke University Hospital, Durham, NC, USA
| | - Ali Zomorodi
- Department of Neurosurgery, Duke University Hospital, Durham, NC, USA
| |
Collapse
|
2
|
Chu HH, Kim GH, Gwon DI. An Alternative Endovascular Technique for Treatment of Pulmonary Arteriovenous Malformation: Micro balloon-occluded Transcatheter Embolization Using n-butyl-2-cyanoacrylate. Cardiovasc Intervent Radiol 2024:10.1007/s00270-024-03704-1. [PMID: 38565715 DOI: 10.1007/s00270-024-03704-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 03/06/2024] [Indexed: 04/04/2024]
Abstract
PURPOSE To investigate the safety and efficacy of microballoon-occluded transcatheter embolization using n-butyl-2-cyanoacrylate (NBCA) in patients with a single pulmonary arteriovenous malformation (PAVM). METHODS From November 2017 to November 2020, this retrospective study included 38 previously untreated patients with a single PAVM who underwent microballoon-occluded transcatheter embolization using NBCA. All 38 patients had follow-up that included simple chest radiography and contrast-enhanced chest computed tomography (CT). RESULTS A microballoon was successfully placed in a feeding artery of the PAVM to control the delivery of the NBCA cast in all 38 patients, with complete embolization of sacs and the feeding artery achieved in all cases. The mean diameters of the feeding artery, sac, and draining vein were 3.9 ± 0.9 mm, 7.5 ± 2.6 mm, and 4.6 ± 1.3 mm, respectively. A fixed 1:2 NBCA/Lipiodol ratio was used, and the mean amount of embolic mixture per patient was 1.4 mL (range 0.6-2.2 mL). There were no complications related to microballoon adhesion and non-target embolization of the systemic circulation. Follow-up CT in all 38 patients with a mean delay of 34.5 ± 8.8 months (range 20.7-56.5 months) showed no continued perfusion of the PAVM. CONCLUSION In our hands, microballoon-occluded n-butyl-2-cyanoacrylate embolization seemed to be safe and appeared to be clinically effective in patients with simple and complex types of single PAVM. Therefore, the present technique has the potential to become a standard treatment for a single PAVM.
Collapse
Affiliation(s)
- Hee Ho Chu
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-Ro 43-Gil, Songpa-Gu, Seoul, 05505, Republic of Korea
| | - Gun Ha Kim
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-Ro 43-Gil, Songpa-Gu, Seoul, 05505, Republic of Korea
| | - Dong Il Gwon
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-Ro 43-Gil, Songpa-Gu, Seoul, 05505, Republic of Korea.
| |
Collapse
|
3
|
Ghesquière L, Bengler C, Drumez E, Subtil D, Houfflin-Debarge V, Insubri S, Garabedian C. Factors associated with successful balloon catheter labor induction in women with a previous caesarean section: A retrospective single-center evaluation. J Gynecol Obstet Hum Reprod 2024; 53:102743. [PMID: 38341084 DOI: 10.1016/j.jogoh.2024.102743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 02/08/2024] [Accepted: 02/08/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND Labor induction of women with a history of uterine scarring is an increasingly frequent situation and one for which there are currently no clear professional recommendations favoring one method over another. The objectives of this study were to determine the success rate of balloon catheter induction in women with a history of caesarean section and to evaluate the main factors associated with vaginal delivery. MATERIALS AND METHODS This single-center retrospective study was conducted between January 1, 2014, and December 31, 2018, in Lille, France, and included all women with one previous caesarean section who were induced by first-line balloon catheter induction. Multivariate analysis was performed to identify the factors associated with the primary outcome (vaginal delivery). RESULTS Of the 310 women in the sample, 192 delivered vaginally (62 %). After adjustment, factors associated with successful induction (vaginal delivery) were the number of previous vaginal deliveries (odds ratio [OR] 1.37; 95 % confidence interval [CI] 1.04-1.81), evolution of the Bishop score after balloon removal (OR 1.24; 95 % CI 1.10-1.41), and the initial Bishop score (OR 1.17; 95 % CI 1.00-1.37). Uterine rupture was observed in three women (1 %). CONCLUSION The vaginal delivery rate after balloon catheter induction in women with a previous caesarean section was 62 %. Prognostic factors for vaginal delivery include previous vaginal delivery, the initial Bishop score, and evolution of the Bishop score after balloon catheter induction.
Collapse
Affiliation(s)
- Louise Ghesquière
- Department of Obstetrics, CHU Lille, Lille F-59000, France; ULR 2694 - METRICS - Health Technology and Medical Practice Assessment, Univ. Lille, CHU Lille, Lille F-59000, France.
| | - Cyril Bengler
- Department of Obstetrics, CHU Lille, Lille F-59000, France
| | - Elodie Drumez
- ULR 2694 - METRICS - Health Technology and Medical Practice Assessment, Univ. Lille, CHU Lille, Lille F-59000, France; Department of Biostatistics, CHRU Lille, France
| | - Damien Subtil
- Department of Obstetrics, CHU Lille, Lille F-59000, France; ULR 2694 - METRICS - Health Technology and Medical Practice Assessment, Univ. Lille, CHU Lille, Lille F-59000, France
| | - Véronique Houfflin-Debarge
- Department of Obstetrics, CHU Lille, Lille F-59000, France; ULR 2694 - METRICS - Health Technology and Medical Practice Assessment, Univ. Lille, CHU Lille, Lille F-59000, France
| | | | - Charles Garabedian
- Department of Obstetrics, CHU Lille, Lille F-59000, France; ULR 2694 - METRICS - Health Technology and Medical Practice Assessment, Univ. Lille, CHU Lille, Lille F-59000, France
| |
Collapse
|
4
|
Del Monte A, Chierchia GB, Della Rocca DG, Pannone L, Sorgente A, Bala G, Monaco C, Mouram S, Capulzini Cremonini L, Audiat C, Praet J, Ramak R, Overeinder I, Ströker E, Sieira J, La Meir M, Brugada P, Sarkozy A, de Asmundis C, Almorad A. Posterior wall isolation via a multi-electrode radiofrequency balloon catheter: feasibility, technical considerations, endoscopic findings and comparison with cryoballoon technologies. J Interv Card Electrophysiol 2024; 67:273-283. [PMID: 37103590 DOI: 10.1007/s10840-023-01549-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 04/10/2023] [Indexed: 04/28/2023]
Abstract
BACKGROUND Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.
Collapse
Affiliation(s)
- Alvise Del Monte
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Gian Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Domenico Giovanni Della Rocca
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium.
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, 78705, USA.
| | - Luigi Pannone
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Cinzia Monaco
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Sahar Mouram
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Lucio Capulzini Cremonini
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Charles Audiat
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | | | - Robbert Ramak
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Ingrid Overeinder
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Erwin Ströker
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Mark La Meir
- Cardiac Surgery Department, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Brussels, Belgium
| | - Pedro Brugada
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Andrea Sarkozy
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Alexandre Almorad
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090, Brussels, Belgium
| |
Collapse
|
5
|
Bruno A, Vendetti F, Papalexis N, Russo M, Papadopoulos D, Mosconi C. Percutaneous balloon-assisted ultrasound-guided direct thrombin embolization of superficial femoral artery pseudoaneurysm: a case series and literature review. CVIR Endovasc 2024; 7:19. [PMID: 38363514 PMCID: PMC10873257 DOI: 10.1186/s42155-024-00428-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 01/18/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND Superficial femoral artery (SFA) pseudoaneurysms, a rare but potentially life-threatening complication, that can arise after vascular interventions or trauma. This case series explores the efficacy and safety of a minimally invasive treatment modality, percutaneous ultrasound-guided thrombin injection (PUGTI) combined with balloon occlusion, in three patients with SFA pseudoaneurysms. CASE PRESENTATION Three patients (age: 71-82 years; 3 female) with SFA pseudoaneurysms underwent PUGTI with balloon occlusion. The procedure involved direct thrombin injection under ultrasound guidance while occluding the parent artery using a balloon catheter. Follow-up was conducted at 1 week and 1 month post-procedure to assess technical success, complications, and recurrence. CONCLUSION PUGTI combined with balloon occlusion appears to be a safe and effective treatment for SFA pseudoaneurysms, particularly for larger pseudoaneurysms. The procedure is associated with a high technical success rate. Balloon occlusion may offer a safer alternative to direct thrombin injection without occlusion, as it potentially minimizes the risk of complications such as distal thromboembolism.
Collapse
Affiliation(s)
- Antonio Bruno
- Alma Mater Studiorum, Università Di Bologna, Bologna, Italy
| | | | | | - Mattia Russo
- Alma Mater Studiorum, Università Di Bologna, Bologna, Italy.
| | | | | |
Collapse
|
6
|
Luo Y, Awoyemi O, Liu S, Niu J, Naidu R, Fang C. From celebration to contamination: Analysing microplastics released by burst balloons. J Hazard Mater 2024; 464:133021. [PMID: 37992504 DOI: 10.1016/j.jhazmat.2023.133021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/07/2023] [Accepted: 11/14/2023] [Indexed: 11/24/2023]
Abstract
Air balloons are a ubiquitous presence in our daily lives, and their rupture may release a substantial quantity of debris, as investigated herein. We employ Raman imaging to capture the fragments resulting from balloon explosions, enabling the identification and direct visualisation of minute microplastic particles / fragments with an improved signal-to-noise ratio for precise quantification. To circumvent the generation of misleading confocal Raman images, we recommend employing terrain mapping to scan the three-dimensional surface of the sample. It is important to acknowledge that the analysis of microplastics at the micro-scale inherently poses limitations in terms of throughput, as it necessitates a trade-off between low and high magnifications. We conduct explosive experiments on ten-to-hundred balloons, collecting debris from various angles and positions. Our investigation involves the random testing of multiple samples / sample positions at the micro-scale, with subsequent extrapolation to estimate the total amount of microplastics. The amalgamation of these results through statistical analysis indicates that each balloon explosion can potentially release tens-to-thousands of microplastics, highlighting a concern that has hitherto received insufficient attention. The characterisation approach, particularly the random Raman scanning method in combination with SEM and the statistical analysis on accumulated samples employed in this report, has the potential to serve as a useful tool in future research on microplastics and even nanoplastics.
Collapse
Affiliation(s)
- Yunlong Luo
- Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia
| | - Olalekan Awoyemi
- Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia
| | - Siyuan Liu
- Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of Newcastle, Callaghan, NSW 2308, Australia
| | - Junfeng Niu
- College of Environmental Science and Engineering, North China Electric Power University, Beijing 102206, PR China
| | - Ravi Naidu
- Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of Newcastle, Callaghan, NSW 2308, Australia
| | - Cheng Fang
- Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of Newcastle, Callaghan, NSW 2308, Australia.
| |
Collapse
|
7
|
Su X, Song Z, Zhang H, Ma Y, Zhang P. Correspondence on 'Embolization strategies for intracranial dural arteriovenous fistulas with an isolated sinus: a single-center experience in 20 patients' by Hendriks et al. J Neurointerv Surg 2024; 16:327-328. [PMID: 37714537 DOI: 10.1136/jnis-2023-020932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 08/19/2023] [Indexed: 09/17/2023]
Affiliation(s)
- Xin Su
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Zihao Song
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Hongqi Zhang
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Yongjie Ma
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Peng Zhang
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
8
|
Salame M, Gleeson FC, Chandrasekhara V, Law RJ, Rajan E, Iyer PG, Bofill-Garcia A, Ghanem OM, Abu Dayyeh BK, Ravi A, Storm AC, Vargas EJ. SAFETY OF ENDOSCOPIC ULTRASONOGRAPHY LATEX BALLOON USE IN PATIENTS WITH A LATEX ALLERGY. Gastrointest Endosc 2024:S0016-5107(24)00051-8. [PMID: 38280533 DOI: 10.1016/j.gie.2024.01.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/16/2024] [Accepted: 01/21/2024] [Indexed: 01/29/2024]
Abstract
BACKGROUND AND AIMS Balloons are used in endoscopic ultrasonography (EUS) to improve visualization. However, data on the safety of latex balloons in patients with latex allergies is limited, and non-latex alternatives can be costly. We aimed to investigate the safety of latex balloon use during EUS. METHODS A retrospective review was conducted at a tertiary center between 2019-2022. Patients with reported latex allergies who underwent linear EUS were included. Baseline demographics, EUS characteristics, and adverse events were collected. The primary outcome was the rate of adverse events. RESULTS 87 procedures were performed on 57 unique patients (mean age 65.3± 14.5 years). Latex balloons were used in 59 procedures (67.8%), with only 8 procedures (13.6%) using prophylactic medications. No adverse events occurred during or after procedures, regardless of medication use or history of anaphylaxis. CONCLUSIONS The use of EUS latex balloons in patients with a latex allergy was associated with no adverse events.
Collapse
Affiliation(s)
- Marita Salame
- Department of Surgery, Mayo Clinic, Rochester, MN, USA
| | - Ferga C Gleeson
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | | | - Ryan J Law
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | - Elizabeth Rajan
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | - Prasad G Iyer
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | | | - Omar M Ghanem
- Department of Surgery, Mayo Clinic, Rochester, MN, USA
| | - Barham K Abu Dayyeh
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | - Anupama Ravi
- Division of Pediatric Allergy and Immunology, Mayo Clinic, Rochester, MN, USA
| | - Andrew C Storm
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | - Eric J Vargas
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
9
|
Takabayashi K, Maeda Y, Kataoka N. Modified procedure for reconstructing the inferomedial orbital wall: silicone sheet implantation without surgical removal. Eur Arch Otorhinolaryngol 2024; 281:515-521. [PMID: 37831133 PMCID: PMC10764395 DOI: 10.1007/s00405-023-08257-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 09/19/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND Due to the complexity of reconstructing wide inferomedial orbital wall fractures, silicone sheets are the preferred choice of reconstructive material. Nevertheless, it is crucial to remove the silicone sheet postoperatively due to the risk of delayed complications associated with its placement. METHODS We developed a procedure in which a silicone sheet implanted in the orbit can be extracted through the nasal cavity by removing the fractured portion of the medial orbital wall. CONCLUSION This procedure enables the utilization of silicone sheets, which are suitable for intricate orbital reconstruction, without any concerns regarding delayed complications.
Collapse
Affiliation(s)
- Kosuke Takabayashi
- Department of Otorhinolaryngology, Japanese Red Cross Asahikawa Hospital, Asahikawa City, Hokkaido, Japan
- Department of Otorhinolaryngology, Sapporo Medical University School of Medicine, Sapporo City, Hokkaido, Japan
| | - Yohei Maeda
- Department of Otorhinolaryngology, Japan Community Health Care Organization Osaka Hospital, 4-2-78 Fukushima, Fukushima-Ku, Osaka City, Osaka, 553-0003, Japan.
- Department of Otorhinolaryngology-Head and Neck Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan.
| | - Nobuya Kataoka
- Department of Ophthalmology, Japanese Red Cross Asahikawa Hospital, Asahikawa City, Hokkaido, Japan
| |
Collapse
|
10
|
Zhang J, Zhang X, Han J. Correspondence on "Comparison of drug-coated balloon with conventional balloon for angioplasty in symptomatic intracranial atherosclerotic stenosis" by Tang et al. J Neurointerv Surg 2023; 15:e484. [PMID: 36990688 DOI: 10.1136/jnis-2023-020284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 03/04/2023] [Indexed: 03/31/2023]
Affiliation(s)
- Jun Zhang
- Department of Neurology, The First Affiliated Hospital of Shandong First Medical University, Jinan, Shandong, China
| | - Xiao Zhang
- Department of Neurology, The First Affiliated Hospital of Shandong First Medical University, Jinan, Shandong, China
| | - Ju Han
- Department of Neurology, The First Affiliated Hospital of Shandong First Medical University, Jinan, Shandong, China
| |
Collapse
|
11
|
Liu W, Tang Y, Li T, He Y. Response to: Correspondence on 'Comparison of drug-coated balloon with conventional balloon for angioplasty in symptomatic intracranial atherosclerotic stenosis' by Zhang et al. J Neurointerv Surg 2023; 15:e485. [PMID: 37989579 DOI: 10.1136/jnis-2023-021191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 11/02/2023] [Indexed: 11/23/2023]
Affiliation(s)
- Wenbo Liu
- Cerebrovascular and Neurosurgery Department of Stroke Center, Zhengzhou University People's Hospital, Zhengzhou, Henan, China
| | - Yao Tang
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Zhengzhou, Henan, China
- Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| | - Tianxiao Li
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Zhengzhou, Henan, China
- Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| | - Yingkun He
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Zhengzhou, Henan, China
- Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| |
Collapse
|
12
|
Tang Y, Li T, Liu W, He Y, Zhu L, Wang ZL, He Y. Comparison of drug-coated balloon with conventional balloon for angioplasty in symptomatic intracranial atherosclerotic stenosis. J Neurointerv Surg 2023; 15:e369-e374. [PMID: 36604174 DOI: 10.1136/jnis-2022-019685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 12/23/2022] [Indexed: 01/07/2023]
Abstract
BACKGROUND Drug-coated balloon (DCB) angioplasty has been studied for reducing the occurrence of restenosis after treatment for intracranial atherosclerotic stenosis (ICAS), but no comparison has been published of the use of drug-coated and non-coated balloons in angioplasty for ICAS. We aim to compare the safety and efficacy of DCB angioplasty with conventional balloon (CB) angioplasty for the treatment of symptomatic ICAS. METHODS One hundred cases with symptomatic ICAS treated with DCB (n=49) and CB (n=51) angioplasty were retrospectively analyzed. 1:1 propensity score matching (PSM) was completed to eliminate bias in the patients selected for further analysis. The periprocedural events and follow-up outcomes between the two groups were compared. RESULTS There were 32 cases in each group after PSM. Technical success (<50% residual stenosis) was achieved in 30 cases (93.8%) in the DCB group and in 28 cases (87.5%) in the CB group. The rates of stroke or mortality within 30 days were 3.1% in the DCB group and 6.3% in the CB group (p=1). The incidence of restenosis in the DCB group (6.3%) was significantly lower than that in the CB group (31.3%) (p=0.01). CONCLUSIONS Compared with CB angioplasty, DCB angioplasty can effectively reduce the incidence of restenosis. Further studies are needed to validate the role of DCB angioplasty in the management of symptomatic ICAS.
Collapse
Affiliation(s)
- Yao Tang
- Cerebrovascular and Neurosurgery Department of Stroke Center, Zhengzhou University People's Hospital, Zhengzhou, Henan, China
| | - Tianxiao Li
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital; Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| | - Wenbo Liu
- Cerebrovascular and Neurosurgery Department of Stroke Center, Zhengzhou University People's Hospital, Zhengzhou, Henan, China
| | - Yanyan He
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital; Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| | - Liangfu Zhu
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital; Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| | - Zi-Liang Wang
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital; Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| | - Yingkun He
- Cerebrovascular and Neurosurgery Department of Interventional Center, Zhengzhou University People's Hospital, Henan Provincial People's Hospital; Henan Provincial Neurointerventional Engineering Research Center, Henan International Joint Laboratory of Cerebrovascular Disease and Henan Engineering Research Center of Cerebrovascular Intervention, Zhengzhou, Henan, China
| |
Collapse
|
13
|
Wu CH, Lin TM, Chung CP, Yu KW, Tai WA, Luo CB, Lirng JF, Chang FC. Prevention of in-stent restenosis with drug-eluting balloons in patients with postirradiated carotid stenosis accepting percutaneous angioplasty and stenting. J Neurointerv Surg 2023; 16:73-80. [PMID: 36914246 PMCID: PMC10804009 DOI: 10.1136/jnis-2022-019957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 02/19/2023] [Indexed: 03/16/2023]
Abstract
OBJECTIVE To investigate the technical safety and outcome of in-stent restenosis (ISR) prevention with drug-eluting balloon (DEB) in patients with postirradiated carotid stenosis (PIRCS) undergoing percutaneous angioplasty and stenting (PTAS). METHODS Between 2017 and 2021, we prospectively recruited patients with severe PIRCS for PTAS. They were randomly separated into two groups based on endovascular techniques performed with and without DEB. Preprocedural and early postprocedural (within 24 hours) MRI, short-term ultrasonography (6 months after PTAS), and long-term CT angiography (CTA)/MR angiography (MRA), 12 months after PTAS, were performed. Technical safety was evaluated based on periprocedural neurological complications and the number of recent embolic ischemic lesions (REIL) in the treated brain territory on diffusion-weighted imaging of early postprocedural MRI. RESULTS Sixty-six (30 with and 36 without DEB) subjects were enrolled, with one failure in techniques. For 65 patients in the DEB versus conventional groups, technical neurological symptoms within 1 month (1/29 (3.4%) vs 0/36; P=0.197) and REIL numbers within 24 hours (1.0±2.1 vs 1.3±1.5; P=0.592) after PTAS showed no differences. Peak systolic velocity (PSVs) on short-term ultrasonography was significantly higher in the conventional group (104.13±42.76 vs .81.95±31.35; P=0.023). The degree of in-stent stenosis (45.93±20.86 vs 26.58±8.75; P<0.001) was higher, and there were more subjects (n=8, 38.9% vs 1, 3.4%; P=0.029) with significant ISR (≥ 50%) in the conventional group than in the DEB group on long-term CTA/MRA. CONCLUSIONS We observed similar technical safety of carotid PTAS with and without DEBs. The number of cases of significant ISR were fewer and the degree of stenosis of ISR was less in primary DEB-PTAS of PIRCS than for conventional PTAS in the 12-month follow-up.
Collapse
Affiliation(s)
- Chia-Hung Wu
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Te-Ming Lin
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chih-Ping Chung
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Kai-Wei Yu
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Wei-An Tai
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chao-Bao Luo
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Radiology, National Defense Medical Center, Taipei, Taiwan
- Department of Biomedical Engineering, Yuanpei University of Medical Technology, Hsinchu, Taiwan
| | - Jiing-Feng Lirng
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Feng-Chi Chang
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| |
Collapse
|
14
|
Findlay MC, Bounajem M, Grandhi R. Correspondence on 'Matched-pair analysis of patients with ischemic stroke undergoing thrombectomy using next-generation balloon guide catheters' by Kim et al. J Neurointerv Surg 2023:jnis-2023-021342. [PMID: 38124175 DOI: 10.1136/jnis-2023-021342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
Affiliation(s)
- Matthew C Findlay
- Spencer Fox Eccles School of Medicine, University of Utah Health, Salt Lake City, Utah, USA
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah Health, Salt Lake City, Utah, USA
| | - Michael Bounajem
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah Health, Salt Lake City, Utah, USA
| | - Ramesh Grandhi
- Department of Neurosurgery, Clinical Neurosciences Center, University of Utah Health, Salt Lake City, Utah, USA
| |
Collapse
|
15
|
Guerreiro H, Flottmann FA, Kyselyova AA, Wagner M, Brekenfeld C, Eckert B, Illies T, Wodarg F, Fiehler J, Bester M. First experience with Walrus balloon guide catheter in a whole-body flow model. Neuroradiology 2023; 65:1787-1792. [PMID: 37640884 PMCID: PMC10654250 DOI: 10.1007/s00234-023-03214-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 08/12/2023] [Indexed: 08/31/2023]
Abstract
PURPOSE Flow arrest using a balloon guide catheter (BGC) in mechanical thrombectomy (MT) due to large vessel occlusion has been associated with better outcomes. Known limitations of currently commercially available BGCs are incompatibility with large bore aspiration catheters (AC) and lack of distal flexibility. Walrus presents variable stiffness and compatibility with large bore AC. The goal of this study is to describe the first experience with Walrus in a realistic stroke simulation model. METHODS A full-length modular vascular model under physiological conditions was used. 8F+-Walrus inner-diameter (ID) 0.087in 95 cm combined with 6F-Sofia AC ID 0.070in 131 cm and an 8F-Flowgate2 BGC ID 0.084in 95 cm with a 5F-Sofia AC ID 0.055in 125 cm were used to perform aspiration MT. User surveys, access to target and occlusion site, technique, time of delivery, anatomical change, and catheter kick-back were assessed. RESULTS Seven neuroradiologists with average of 10 years-experience in MT performed primary aspiration using the above-mentioned combinations in three different anatomies (N = 41). All operators would likely (29%) or very likely (71%) use again Walrus in combination with large bore AC and the majority (86%) found its navigability easier than with other BGCs. Time to reach final BGC position and catheter kick-back did not differ significantly among anatomies or catheter combinations (p > 0.05). However, Walrus was more likely to reach ICA petrous segment (p < 0.05) and intracranial occlusion with AC (p < 0.01). CONCLUSION The Walrus combined with large bore AC presented significantly better distal access and navigability for primary aspiration in an in vitro stroke model.
Collapse
Affiliation(s)
- Helena Guerreiro
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany.
| | - Fabian A Flottmann
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Anna A Kyselyova
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Maximilian Wagner
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Caspar Brekenfeld
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Bernd Eckert
- Department of Radiology and Neuroradiology, Asklepios Klinik Altona, Hamburg, Germany
| | - Till Illies
- Department of Radiology and Neuroradiology, Asklepios Klinik Altona, Hamburg, Germany
| | - Fritz Wodarg
- Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Kiel, Germany
| | - Jens Fiehler
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Maxim Bester
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| |
Collapse
|
16
|
Scarcia L, Kalamarides M, Shotar E, Premat K, Drir M, Sourour N, Clarençon F. Direct puncture embolization of a medulla oblongata hemangioblastoma. J Neuroradiol 2023:S0150-9861(23)00267-5. [PMID: 37993097 DOI: 10.1016/j.neurad.2023.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 11/18/2023] [Accepted: 11/20/2023] [Indexed: 11/24/2023]
Abstract
Hemangioblastoma is a rare tumor of vascular origin, most commonly located in the posterior fossa, which presents with severe symptoms and usually very hard to resect without remarkable operative blood loss.1-2 Pre-operative embolization may decrease the amount of intra-operative bleeding, but the endovascular treatment of such tumor may be very challenging due to the high risk of infarction of the surrounding tissues. Direct puncture embolization has been developed to overcome many of the limitations of endovascular techniques for many hypervascular lesions, also hemangioblastomas.3-5 We present in this Technical Video (video 1) a direct puncture embolization with balloon-protection of a hemangioblastoma of the medulla oblongata using Onyx 18 (Medtronic, inc.) as sole liquid embolic agent.
Collapse
Affiliation(s)
- Luca Scarcia
- Department of Neuroradiology, Henri Mondor Hospital, Creteil, France.
| | - Michel Kalamarides
- Neurosurgery Department, Pitié-Salpêtrière, APHP, Sorbonne University, Paris, France
| | - Eimad Shotar
- Department of Neuroradiology, Pitié-Salpêtrière Hospital. Paris, France
| | - Kevin Premat
- Department of Neuroradiology, Pitié-Salpêtrière Hospital. Paris, France
| | - Mehdi Drir
- Department of Anesthesiology and Neuro-intensive care, Sorbonne University, APHP, Pitié-Salpêtrière Hospital, Paris, France
| | - Nader Sourour
- Department of Neuroradiology, Pitié-Salpêtrière Hospital. Paris, France
| | - Frédéric Clarençon
- Department of Neuroradiology, Pitié-Salpêtrière Hospital. Paris, France; GRC BioFast, Sorbonne University, Paris, France
| |
Collapse
|
17
|
Orscelik A, Kallmes DF, Bilgin C, Musmar B, Senol YC, Kobeissi H, Elawady SS, Cunningham C, Matsukawa H, Zandpazandi S, Sowlat MM, Maier I, Al Kasab S, Jabbour P, Kim JT, Wolfe SQ, Rai A, Starke RM, Psychogios MN, Samaniego EA, Arthur AS, Yoshimura S, Cuellar H, Howard BM, Alawieh A, Romano DG, Tanweer O, Mascitelli J, Fragata I, Polifka AJ, Osbun JW, Crosa RJ, Matouk C, Park MS, Levitt MR, Moss M, Dumont TM, Williamson R, Navia P, Kan P, De Leacy R, Chowdhry SA, Ezzeldin M, Spiotta AM, Brinjikji W. Comparison of balloon guide catheter versus non-balloon guide catheter for mechanical thrombectomy in patients with distal medium vessel occlusion. J Neurointerv Surg 2023:jnis-2023-020925. [PMID: 37918906 DOI: 10.1136/jnis-2023-020925] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 10/19/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND Several studies have established the safety and efficacy of balloon guide catheters (BGCs) for large vessel occlusions. However, the utility of BGCs remains largely unexplored for distal medium vessel occlusions (DMVOs). In this study, we aim to compare the outcomes of BGC vs. Non-BGC in patients undergoing mechanical thrombectomy (MT) for DMVO. METHOD This retrospective study from the Stroke Thrombectomy and Aneurysm Registry (STAR) encompassed adult patients with acute anterior cerebral artery, posterior cerebral artery, and middle cerebral artery-M2-3-4 occlusions. Procedure times, safety, recanalization, and neurological outcomes were compared between the two groups, with subgroup analysis based on first-line thrombectomy techniques. RESULTS A total of 1508 patients were included, with 231 patients (15.3%) in the BGC group and 1277 patients (84.7%) in the non-BGC group. The BGC group had a lower modified Thrombolysis in Cerebral Infarction (mTICI) score ≥2C (43.2% vs 52.7%, P=0.01), longer time from puncture to intracranial access (15 vs 8 min, P<0.01), and from puncture to final recanalization (97 vs 34 min, P<0.01). In the Solumbra subgroup, the first pass effect (FPE) rate was lower in the BGC group (17.4% vs 30.7%, P=0.03). Regarding clinical outcomes, the BGC group had a lower rate of distal embolization (8.8% vs 14.9%, P=0.03). CONCLUSION Our study found that use of BGC in patients with DMVO was associated with lower mTICI scores, decreased FPE rates, reduced distal embolization, and longer procedure times.
Collapse
Affiliation(s)
- Atakan Orscelik
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - David F Kallmes
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
| | - Cem Bilgin
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
| | - Basel Musmar
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
| | - Yigit Can Senol
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
| | - Hassan Kobeissi
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
| | - Sameh Samir Elawady
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Conor Cunningham
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Hidetoshi Matsukawa
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
- Department of Neurosurgery, Hyogo College of Medicine, Nishinomiya, Hyogo, Japan
| | - Sara Zandpazandi
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Mohammad-Mahdi Sowlat
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Ilko Maier
- Department of Neurology, University Medicine Goettingen, Goettingen, NS, Germany
| | - Sami Al Kasab
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Pascal Jabbour
- Department of Neurological Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Joon-Tae Kim
- Department of Neurology, Chonnam National University Hospital, Gwangju, Gwangju, Korea (the Republic of)
| | - Stacey Q Wolfe
- Department of Neurosurgery, Wake Forest School of Medicine, Winston Salem, North Carolina, USA
| | - Ansaar Rai
- Department of Radiology, West Virginia University Hospitals, Morgantown, West Virginia, USA
| | - Robert M Starke
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Marios-Nikos Psychogios
- Department of Neuroradiology, Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Basel, Switzerland
| | - Edgar A Samaniego
- Department of Neurology, The University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA
| | - Adam S Arthur
- Department of Neurosurgery, University of Tennessee Health Science Center/Semmes Murphey Foundation, Memphis, Tennessee, USA
| | - Shinichi Yoshimura
- Department of Neurosurgery, Hyogo College of Medicine, Nishinomiya, Hyogo, Japan
| | - Hugo Cuellar
- Department of Neurosurgery, Louisiana State University Health Shreveport, Shreveport, Louisiana, USA
| | - Brian M Howard
- Department of Neurosurgery, Emory University, Atlanta, Georgia, USA
| | - Ali Alawieh
- Department of Neurosurgery, Emory University, Atlanta, Georgia, USA
| | - Daniele G Romano
- Department of Neuroradiology, University Hospital 'San Giovanni di Dio e Ruggi d'Aragona', Salerno, Italy
| | - Omar Tanweer
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | - Justin Mascitelli
- Department of Neurosurgery, The University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Isabel Fragata
- Department of Neuroradiology, Centro Hospitalar de Lisboa Central, Lisboa, Portugal
| | - Adam J Polifka
- Department of Neurosurgery, University of Florida, Gainesville, Florida, USA
| | - Joshua W Osbun
- Department of Neurosurgery, Washington University in Saint Louis School of Medicine, Saint Louis, Missouri, USA
| | - Roberto Javier Crosa
- Department of Endovascular Neurosurgery, Médica Uruguaya, Montevideo, Montevideo, Uruguay
| | - Charles Matouk
- Department of Neurosurgery, Yale University, New Haven, Connecticut, USA
| | - Min S Park
- Department of Neurosurgery, University of Virginia, Charlottesville, Virginia, USA
| | - Michael R Levitt
- Department of Neurological Surgery, University of Washington, Seattle, Washington, USA
| | - Mark Moss
- Department of Interventional Neuroradiology, Washington Regional Medical Center, Fayetteville, Arkansas, USA
| | - Travis M Dumont
- Department of Surgery, Division of Neurosurgery, University of Arizona/Arizona Health Science Center, Tucson, Arizona, USA
| | - Richard Williamson
- Department of Neurology, Allegheny Health Network, Pittsburgh, Pennsylvania, USA
| | - Pedro Navia
- Department of Interventional and Diagnostic Neuroradiology, Hospital Universitario La Paz, Madrid, Spain
| | - Peter Kan
- Department of Neurosurgery, The University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Reade De Leacy
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Shakeel A Chowdhry
- Department of Neurosurgery, North Shore University Health System, Evanston, Illinois, USA
| | - Mohamad Ezzeldin
- Department of Clinical Sciences, University of Houston, HCA Houston Healthcare, Kingwood, Texas, USA
| | - Alejandro M Spiotta
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Waleed Brinjikji
- Department of Radiology, Mayo Clinic Rochester, Rochester, Minnesota, USA
| |
Collapse
|
18
|
Qiao H, Chang CH, Wang AYC, Li S, Yang W, Li G, Cen X, Wang R, Lin H. Safety and efficacy of drug coated balloon angioplasty for intracranial atherosclerotic disease. J Neurointerv Surg 2023; 15:e172-e177. [PMID: 36171100 DOI: 10.1136/jnis-2022-019122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 09/13/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND Drug coated balloon (DCB) angioplasty can provide sustained anti-restenotic efficacy without the limitations of permanent vascular implantation and is presumably ideal for treating intracranial atherosclerotic disease. However, the safety of paclitaxel in the neurovasculature remains a concern. METHODS 242 patients with angiographically verified symptomatic stenosis >70% in intracranial arteries treated with DCB angioplasty were reviewed divided into two groups: group A, patients with stenotic intracranial arteries; and group B, patients with acute, subacute, or chronic occluded intracranial arteries. The primary endpoint was any stroke or death within 30 days. The secondary endpoint was arterial restenosis of >50% during follow-up. RESULTS 16 major and 12 minor complications occurred among 245 procedures (6.5% and 4.9%, respectively). Five patients died within 30 days after the procedure (2.1%, 5/242). 12 major and 12 minor complications occurred among 211 procedures in group A (5.7% and 5.7%). In group B, four major complications occurred among 34 procedures (11.8%). Hyperperfusion and perforator stroke accounted for half of all complications (53.6%, 15/28). Restenosis >50% was present in eight lesions during the follow-up period (4.8%, 8/167). CONCLUSIONS After treatment with DCB angioplasty, complications were no different from those after standard balloon angioplasty or stenting. This study suggests that DCB angioplasty may be a safe and effective procedure for intracranial arterial stenosis.
Collapse
Affiliation(s)
- Hanzi Qiao
- Neurology, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| | - Chien-Hung Chang
- Neurology, Chang Gung Memorial Hospital Linkou Branch, Gueishan, Taoyuan, Taiwan
| | - Alvin Yi-Chou Wang
- Department of Neurosurgery, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| | - Shaoxue Li
- Neurosurgical Department, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| | - Weilin Yang
- Brain Center, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| | - Guoming Li
- Neurology Department, Second Clinical Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xuecheng Cen
- Neurosurgical Department, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| | - Rongfei Wang
- Department of Neurology, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| | - Hao Lin
- Neurological Department, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou, Guangdong, China
| |
Collapse
|
19
|
Karas PJ, Lee JE, Frank TS, Morden FT, Shaltoni H, Kan P. Robotic-guided direct transtemporal embolization of an indirect carotid cavernous fistula. J Neurointerv Surg 2023; 15:1122-1123. [PMID: 36627196 DOI: 10.1136/jnis-2022-019868] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 12/28/2022] [Indexed: 01/11/2023]
Abstract
A middle-aged patient presented with right-sided chemosis, exophthalmos, and progressive visual loss. Digital subtraction angiography revealed a type D carotid-cavernous fistula (CCF). Transarterial embolization through the internal maxillary artery was unsuccessful, and there was no venous access to the CCF. A robotic-guided direct transtemporal embolization of the CCF with Onyx was performed, resulting in successful fistula obliteration and symptom resolution. This is the first reported case of a robotic-guided direct transcranial CCF embolization. We include a technical video that demonstrates this procedure (Supplemental File 1).
Collapse
Affiliation(s)
- Patrick J Karas
- Department of Neurosurgery, University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Jae Eun Lee
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | - Thomas S Frank
- Department of Neurosurgery, University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Frances Tiffany Morden
- Department of Neurosurgery, University of Hawai'i at Mānoa John A Burns School of Medicine, Honolulu, Hawaii, USA
| | - Hashem Shaltoni
- Department of Neurology, University of Texas Medical Branch, Galveston, Texas, USA
| | - Peter Kan
- Department of Neurosurgery, University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| |
Collapse
|
20
|
Song X, Fu Y, Lai Z, Di X, Zeng R, Shao J, Ni L, Liu Z, Song X, Ye W, Liu C, Liu B, Zheng Y, Chen Y. Drug-coated balloon for treatment of non-atherosclerotic renal artery stenosis-a multi-center study. BMC Cardiovasc Disord 2023; 23:510. [PMID: 37845604 PMCID: PMC10577992 DOI: 10.1186/s12872-023-03484-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 08/30/2023] [Indexed: 10/18/2023] Open
Abstract
INTRODUCTION Renal artery stenosis (RAS) is a significant reason for secondary hypertension. Impaired renal function and subsequent cardiopulmonary dysfunction could also occur. Patients of non-atherosclerotic RAS has a relatively young age and long life expectancy. Revascularization with percutaneous transluminal angioplasty (PTA) is a viable treatment option. However, restenosis is unavoidable which limits its use. Drug-coated balloon (DCB) has been proven to be effective in restenosis prevention in femoropopliteal arterial diseases and in patients with renal artery stenosis. And PTA for Renal artery fibromuscular dysplasia is safe and clinically successful. Therefore, we could speculate that DCB might have potential efficacy in non-atherosclerotic RAS treatment. METHODS AND ANALYSIS This will be a randomized multi-center-controlled trial. Eighty-four eligible participants will be assigned randomly in a 1:1 ratio to the control group (plain old balloon, POB) and the experimental group (DCB). Subjects in the former group will receive balloon dilatation alone, and in the latter group will undergo the DCB angioplasty. The DCB used in this study will be a paclitaxel-coated balloon (Orchid, Acotec Scientific Holdings Limited, Beijing, China). Follow-up visits will be scheduled 1, 3, 6, 9, and 12 months after the intervention. Primary outcomes will include controlled blood pressure and primary patency in the 9-month follow-up. Secondary outcomes will include technical success rate, complication rate, and bail-out stenting rate. TRIAL REGISTRATION ClinicalTrials.gov (number NCT05858190). Protocol version V.4 (3 May 2023).
Collapse
Affiliation(s)
- Xitao Song
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Yining Fu
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Zhichao Lai
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Xiao Di
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Rong Zeng
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Jiang Shao
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Leng Ni
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Zhili Liu
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Xiaojun Song
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Wei Ye
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Changwei Liu
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Bao Liu
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Yuehong Zheng
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China
| | - Yuexin Chen
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1st, Dongcheng District, Beijing, 100730, China.
| |
Collapse
|
21
|
Kim LH, Choi J, Zhou J, Wolman D, Pendharkar AV, Lansberg MG, Albers GW, Dodd R, Do HM, Pulli B, Heit JJ, Telischak NA. Matched-pair analysis of patients with ischemic stroke undergoing thrombectomy using next-generation balloon guide catheters. J Neurointerv Surg 2023:jnis-2023-020635. [PMID: 37793796 DOI: 10.1136/jnis-2023-020635] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 09/08/2023] [Indexed: 10/06/2023]
Abstract
BACKGROUND Balloon guide catheters (BGCs) have not been widely adopted, possibly due to the incompatibility of past-generation BGCs with large-bore intermediate catheters. The next-generation BGC is compatible with large-bore catheters. We compared outcomes of thrombectomy cases using BGCs versus conventional guide catheters. METHODS We conducted a retrospective study of 110 thrombectomy cases using BGCs (n=55) and non-BGCs (n=55). Sixty consecutive thrombectomy cases in whom the BOBBY BGC was used at a single institution between February 2021 and March 2022 were identified. Of these, 55 BGC cases were 1:1 matched with non-BGC cases by proceduralists, age, gender, stent retriever + aspiration device versus aspiration-only, and site of occlusion. First-pass effect was defined as Thrombolysis In Cerebral Infarction 2b or higher with a single pass. RESULTS The BGC and non-BGC cohorts had similar mean age (67.2 vs 68.9 years), gender distribution (43.6% vs 47.3% women), median initial National Institutes of Health Stroke Scale score (14 vs 15), and median pretreatment ischemic core volumes (12 mL vs 11.5 mL). BGC and non-BGC cases had similar rates of single pass (60.0% vs 54.6%), first-pass effect (58.2% vs 49.1%), and complications (1.8% vs 9.1%). In aspiration-only cases, the BGC cohort had a significantly higher rate of first-pass effect (100% vs 50.0%, p=0.01). BGC was associated with a higher likelihood of achieving a modified Rankin Scale score of 2 at discharge (OR 7.76, p=0.02). No additional procedural time was required for BGC cases (46.7 vs 48.2 min). CONCLUSION BGCs may be safely adopted with comparable procedural efficacy, benefits to aspiration-only techniques, and earlier functional improvement compared with conventional guide catheters.
Collapse
Affiliation(s)
- Lily H Kim
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - John Choi
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - James Zhou
- California Northstate University College of Medicine, Elk Grove, California, USA
| | - Dylan Wolman
- Radiology, Kaiser Permanente, Portland, Oregon, USA
| | - Arjun V Pendharkar
- Department of Neurosurgery, Stanford University School of Medicine, Stanford, California, USA
| | - Maarten G Lansberg
- Neurology and Neurological Sciences, Stanford University, Stanford, California, USA
| | - Gregory W Albers
- Neurology and Neurological Sciences, Stanford University, Stanford, California, USA
| | - Robert Dodd
- Neurosurgery and Radiology, Stanford University, Stanford, California, USA
| | - Huy M Do
- Radiology, Neuroadiology and Neurointervention Division, Stanford University, Stanford, California, USA
| | - Benjamin Pulli
- Radiology, Neuroadiology and Neurointervention Division, Stanford University, Stanford, California, USA
| | - Jeremy J Heit
- Radiology, Neuroadiology and Neurointervention Division, Stanford University, Stanford, California, USA
| | - Nicholas A Telischak
- Radiology, Neuroadiology and Neurointervention Division, Stanford University, Stanford, California, USA
| |
Collapse
|
22
|
Kim HR, Kim MJ, Kim S, Chang MS, Kim DJ, Kim BM, Park KY, Kim YB, Lee CS, Byeon SH, Kim SS, Lee SW, Kim YJ. Retinal artery/arteriole occlusion risks after endovascular treatment for unruptured intracranial aneurysm. Stroke Vasc Neurol 2023:svn-2023-002563. [PMID: 37793900 DOI: 10.1136/svn-2023-002563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 09/10/2023] [Indexed: 10/06/2023] Open
Abstract
BACKGROUND To evaluate the association between retinal artery/arteriole occlusion (RAO) and unruptured intracranial aneurysm (UIA). METHODS Incident UIA patients from a nationwide cohort (n=253 240) were categorised into three groups based on subsequent treatment: observation (n=208 993), microsurgical clipping (n=14 168) and endovascular treatment (EVT) groups (n=30 079). The incidence and the incident time of RAO were analysed. HRs of RAO and associated risk factors were evaluated. Additionally, a hospital cohort comprising 2569 consecutive UIA patients treated at a tertiary hospital was analysed with detailed clinical information of UIAs. RESULTS In the nationwide cohort analysis, the incidence of RAO was significantly higher in EVT group than in observation and clipping groups, especially within 60 days (early RAO (within 60 days): HR=4.00, 95% CI: 2.44 to 6.56); delayed RAO (after 60 days): HR=1.74, 95% CI: 1.13 to 2.68). Multivariable analysis showed that the presence of chronic kidney disease (p=0.009) and use of a balloon microcatheter during the procedure (p=0.013) were associated with a higher risk of RAO. In hospital cohort analysis, 11 (0.8%) cases of RAO occurred after EVT, whereas none occurred after microsurgical clipping (p<0.001). Patients with RAO were younger and received balloon microcatheters more frequently than their counterparts. Ten cases of RAO (90.9%) occurred in paraclinoid aneurysms, where EVT was preferred over microsurgical clipping. CONCLUSIONS Performing EVT for UIA may increase the risk of subsequent RAO. Care should be taken when treating paraclinoid aneurysms with balloon microcatheters.
Collapse
Affiliation(s)
- Hae Rang Kim
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University College of Medicine, Seongnam, Korea (the Republic of)
| | - Min Jeoung Kim
- Department of Neurosurgery, Severance Stroke Center, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
- Department of Neurosurgery, Uijeongbu St. Mary's Hospital, The Catholic University of Korea College of Medicine, Uijeongbu, Korea (the Republic of)
| | - Sunyeup Kim
- Department of Medical AI, Sungkyunkwan University School of Medicine, Suwon, Korea (the Republic of)
| | - Myung Soo Chang
- Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Dong Joon Kim
- Department of Radiology, Severance Stroke Center, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Byung Moon Kim
- Department of Radiology, Severance Stroke Center, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Keun Young Park
- Department of Neurosurgery, Severance Stroke Center, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Yong Bae Kim
- Department of Neurosurgery, Severance Stroke Center, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Christopher Seungkyu Lee
- Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Suk Ho Byeon
- Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Sung Soo Kim
- Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| | - Seung Won Lee
- Department of Precision Medicine, Sungkyunkwan University School of Medicine, Suwon, Korea (the Republic of)
| | - Yong Joon Kim
- Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea (the Republic of)
| |
Collapse
|
23
|
Cummins DD, Caton MT, Hemphill K, Lamboy A, Tu-Chan A, Meisel K, Narsinh KH, Amans MR. Cerebrovascular pulsatile tinnitus: causes, treatments, and outcomes in 164 patients with neuroangiographic correlation. J Neurointerv Surg 2023; 15:1014-1020. [PMID: 36190940 DOI: 10.1136/jnis-2022-019259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 08/29/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND Pulsatile tinnitus (PT) can cause significant detriment to quality of life and may herald a life-threatening condition. Endovascular evaluation is the gold standard for the definitive diagnosis of PT and facilitates treatment. However, no large study has determined the distribution of causes and treatment outcomes of PT evaluated endovascularly. METHODS Consecutive patients evaluated at a multidisciplinary PT clinic from a single academic center were retrospectively reviewed. Patients with a suspected cerebrovascular etiology of PT based on clinical and/or non-invasive imaging, who were evaluated by endovascular techniques (arteriography, venography, manometry, and/or balloon test occlusion), were included in analysis. Baseline clinical features and treatment results by final etiology of PT were compared. RESULTS Of 552 patients referred for PT evaluation, 164 patients (29.7%) who underwent endovascular evaluation of PT were included. Mean (±SD) age at first clinical evaluation was 54.3±14.1 years (range 25-89 years); 111 patients (67.7%) were female. PT causes were 75.6% vascular and 24.4% non-vascular. Arteriovenous shunting lesions caused 20.7% of cases, venous etiologies 48.2%, and arterial etiologies 6.7%. Of patients with a shunting lesion treated with endovascular embolization, 96.9% had lasting significant improvement or resolution in PT. Endovascular stenting for venous sinus stenosis gave 84.6% of patients lasting improvement or resolution in PT. Arterial and non-vascular PT had fewer patients treated endovascularly and less improvement in PT symptoms. CONCLUSION PT with a suspected vascular cause is most often attributable to venous etiologies. PT caused by arteriovenous shunting or venous sinus stenosis may be effectively treated endovascularly.
Collapse
Affiliation(s)
- Daniel D Cummins
- School of Medicine, University of California San Francisco, San Francisco, California, USA
| | - M Travis Caton
- Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Kafi Hemphill
- Neurology, University of California San Francisco, San Francisco, California, USA
| | - Allison Lamboy
- Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Adelyn Tu-Chan
- Neurology, University of California San Francisco, San Francisco, California, USA
| | - Karl Meisel
- Neurology, University of California San Francisco, San Francisco, California, USA
| | - Kazim H Narsinh
- Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| | - Matthew R Amans
- Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
24
|
Abbitt D, Netsanet A, Kovar A, Choy K, Jones TS, Cassell B, Hammad H, Reveille RM, Wikiel KJ, Jones EL. Losing weight to achieve joint or hernia surgery: is the intragastric balloon the answer? Surg Endosc 2023; 37:7212-7217. [PMID: 37365392 DOI: 10.1007/s00464-023-10209-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 06/11/2023] [Indexed: 06/28/2023]
Abstract
BACKGROUND Obesity is an epidemic, with its accompanying medical conditions putting patients at increased risk of postoperative complications. For patients undergoing elective surgery, preoperative weight loss provides an opportunity to decrease complications. We sought to evaluate the safety and efficacy of an intragastric balloon in achieving a body mass index (BMI) < 35 kg/m2 prior to elective joint replacement or hernia repair. METHODS Retrospective review of all patients who had intragastric balloon placement at a level 1A VA medical center from 1/2019 to 1/2023. Patients who had a scheduled qualifying procedure (knee/hip replacement or hernia repair) and had a BMI > 35 kg/m2 were offered intragastric balloon placement to achieve 30-50lbs (13-28 kg) weight loss prior to surgery. Participation in a standardized weight loss program for 12 months was required. Balloons were removed 6 months after placement, preferentially concomitant with the qualifying procedure. Baseline demographics, duration of balloon therapy, weight loss and progression to qualifying procedure were recorded. RESULTS Twenty patients completed intragastric balloon therapy and had balloon removal. Mean age 54 (34-71 years), majority (95%) male. Mean balloon duration was 200 ± 37 days. Mean weight loss was 30.8 ± 17.7lbs (14.0 ± 8.0 kg) with an average BMI reduction of 4.4 ± 2.9. Seventeen (85%) patients were successful, 15 (75%) underwent elective surgery and 2 (10%) were no longer symptomatic after weight loss. Three patients (15%) did not lose sufficient weight to qualify or were too ill to undergo surgery. Nausea was the most frequent side effect. One (5%) patient was readmitted within 30 days for pneumonia. DISCUSSION Intragastric balloon placement resulted in an average 30lbs (14 kg) weight loss over 6 months allowing more than 75% of patients to undergo joint replacement or hernia repair at an optimal weight. Intragastric balloons should be considered in patients requiring 30-50lbs (13-28 kg) weight loss prior to elective surgery. More study is needed to determine the long-term benefit of preoperative weight loss prior to elective surgery.
Collapse
Affiliation(s)
- Danielle Abbitt
- Department of Surgery, University of Colorado School of Medicine, 12631 E 17Th Ave, Aurora, CO, C-305, USA.
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA.
| | - Adom Netsanet
- School of Medicine, University of Colorado, Aurora, CO, USA
| | - Alexandra Kovar
- Department of Surgery, University of Colorado School of Medicine, 12631 E 17Th Ave, Aurora, CO, C-305, USA
| | - Kevin Choy
- Department of Surgery, University of Colorado School of Medicine, 12631 E 17Th Ave, Aurora, CO, C-305, USA
| | - Teresa S Jones
- Department of Surgery, University of Colorado School of Medicine, 12631 E 17Th Ave, Aurora, CO, C-305, USA
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA
| | - Benjamin Cassell
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA
- Department of Gastroenterology, University of Colorado School of Medicine, Aurora, CO, USA
| | - Hazem Hammad
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA
- Department of Gastroenterology, University of Colorado School of Medicine, Aurora, CO, USA
| | - Robert Matthew Reveille
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA
- Department of Gastroenterology, University of Colorado School of Medicine, Aurora, CO, USA
| | - Krzysztof J Wikiel
- Department of Surgery, University of Colorado School of Medicine, 12631 E 17Th Ave, Aurora, CO, C-305, USA
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA
| | - Edward L Jones
- Department of Surgery, University of Colorado School of Medicine, 12631 E 17Th Ave, Aurora, CO, C-305, USA
- Rocky Mountain Regional Veteran Affairs Medical Center, Aurora, CO, USA
| |
Collapse
|
25
|
Yang K, Fang S, Zhang X, Wang T, Feng Y, Jiao L, Yan Y. In-stent restenosis after vertebral artery origin stenosis stenting: a nomogram for risk assessment. J Neurointerv Surg 2023; 15:e41-e45. [PMID: 35896318 DOI: 10.1136/neurintsurg-2022-019091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 06/07/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To propose a nomogram for individual risk assessment of in-stent restenosis (ISR) after vertebral artery origin stenosis (VAOS) stenting. METHODS We included 793 patients with VAOS treated with stenting from October 2006 to May 2013, with a median follow-up of 27.8 months. Cox regression and the least absolute shrinkage and selection operator (LASSO) regression were adopted for variable selection. The nomogram was formulated and validated by concordance indexes (C-indexes) and calibration curves. An in-stent restenosis risk table (ISR-RT) was subsequently generated for risk stratification. Differences between low-, intermediate-, and high-risk levels were shown by Kaplan-Meier curves and compared by log-rank test. RESULTS The training and validation set included 594 and 199 patients, with a mean ISR rate of 37.2% and 35.2%, respectively. Stent type (HR=1.64, 95% CI 1.26 to 2.14), stent diameter (HR=2.48, 95% CI 1.77 to 3.48), history of peripheral vascular disease (HR=2.17, 95% CI 1.17 to 4.00), history of transit ischemic attack (HR=1.45, 95% CI 1.05 to 2.14), and left-side involvement (HR=1.33, 95% CI 1.04 to 1.69) were included in the nomogram. The C-indexes at 6 and 12 months were 0.650 and 0.611 in the training set, and 0.713 and 0.603 in the validation set, respectively. Compared with low-risk patients, the intermediate- and high-level group had 1.46 (95% CI 1.05 to 2.04; p=0.0235) and 2.28 (95% CI 1.64 to 3.17; p<0.0001) higher chances of developing ISR in 2 years, respectively. CONCLUSIONS A nomogram and a risk evaluation table were developed with good predictive ability for in-stent restenosis among patients with VAOS, which could serve as a practical approach for individualized risk evaluation.
Collapse
Affiliation(s)
- Kun Yang
- Department of Epidemiology and Biostatistics, Municipal Key Laboratory of Clinical Epidemiology, Capital Medical University School of Public Health, Beijing, China
- Evidence-based Medicine Center, Xuanwu Hospital Capital Medical University, Beijing, China
| | - Shiyuan Fang
- Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xiao Zhang
- Department of Neurosurgery, Xuanwu Hospital Capital Medical University, Beijing, China
| | - Tao Wang
- Department of Neurosurgery, Xuanwu Hospital Capital Medical University, Beijing, China
| | - Yiding Feng
- Department of Neurosurgery, Xuanwu Hospital Capital Medical University, Beijing, China
| | - Liqun Jiao
- Department of Neurosurgery, Xuanwu Hospital Capital Medical University, Beijing, China
- China International Neuroscience Institute, Beijing, China
| | - Yuxiang Yan
- Department of Epidemiology and Biostatistics, Municipal Key Laboratory of Clinical Epidemiology, Capital Medical University School of Public Health, Beijing, China
| |
Collapse
|
26
|
Parat D, Granger B, Shotar E, Premat K, Reina V, Drir M, Gerschenfeld G, Talbi A, Lenck S, Sourour N, Clarençon F. 'Pressure cooker' and ' balloon pressure' techniques significantly increase 3-month complete occlusion rate after spinal arteriovenous fistula embolization as compared to glue: single center evaluation on 38 consecutive patients. J Neurointerv Surg 2023:jnis-2023-020621. [PMID: 37611938 DOI: 10.1136/jnis-2023-020621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 08/01/2023] [Indexed: 08/25/2023]
Abstract
BACKGROUND Spinal arteriovenous fistulas can be treated either by surgery or by endovascular means, using different strategies. The main drawback of embolization is the risk of recurrence. Our objective is to evaluate the angiographic occlusion rate and the predictive factors of angiographic cure of spinal arteriovenous fistulas at 3 months or more after embolization. METHODS This is a retrospective single-center study including 38 consecutive patients with spinal arteriovenous fistulas treated by embolization as first-line treatment. We reviewed clinical and imaging data, complications, and the immediate angiographic occlusion rate of the fistulas, and at 3 months or more after the embolization. RESULTS A total of 45 embolization procedures were performed: 30 procedures using glue, 15 using Onyx by 'pressure cooker' or 'balloon pressure' techniques. We observed no statistically significant difference between the two groups concerning the immediate angiographic occlusion rate (87% in both groups; P>0.9), as well as for periprocedural complication rates. The angiographic occlusion rate at 3 months or more was higher in the Onyx 'combined' techniques treated group (87% vs 40%, P=0.007). The use of Onyx 'combined' techniques was independently associated with angiographic cure at 3 months after embolization (P=0.029). No other factors were identified as predictive of angiographic cure and clinical recovery after embolization procedures, nor were any predictive factors identified for the occurrence of periprocedural complications. CONCLUSION Embolization of spinal arteriovenous fistulas with Onyx using 'combined' techniques appears to be safe and associated with a higher rate of angiographic occlusion at 3 months than regular embolization with glue.
Collapse
Affiliation(s)
- Damien Parat
- Radiologie, Assistance Publique - Hopitaux de Paris, Paris, France
| | - Benjamin Granger
- Department of Public Health, APHP, Paris, France
- Sorbonne University, Paris, France
| | - Eimad Shotar
- Department of Interventional Neuroradiology, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | - Kevin Premat
- Department of Interventional Neuroradiology, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | - Vincent Reina
- Department of Neurosurgery, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | - Mehdi Drir
- Department of Neurosurgery, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | | | - Atika Talbi
- Department of Interventional Neuroradiology, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | - Stephanie Lenck
- Department of Interventional Neuroradiology, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | - Nader Sourour
- Department of Interventional Neuroradiology, Pitié-Salpêtrière Hospital, APHP, Paris, France
| | - Frédéric Clarençon
- Sorbonne University, Paris, France
- Department of Interventional Neuroradiology, Pitié-Salpêtrière Hospital, APHP, Paris, France
- GRC BioFast, Sorbonne University, Paris, France
| |
Collapse
|
27
|
Ghibes P, Grözinger G, Hartleif S, Sturm E, Hefferman GM, Nadalin S, Tsiflikas I, Schäfer JF, Artzner C. Balloon angioplasty versus stent placement for the treatment of portal vein stenosis in children: a single center experience. Pediatr Radiol 2023; 53:1885-1893. [PMID: 37147428 DOI: 10.1007/s00247-023-05674-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 04/10/2023] [Accepted: 04/11/2023] [Indexed: 05/07/2023]
Abstract
PURPOSE To evaluate the safety and efficacy of percutaneous interventional treatment of portal vein stenosis in children. MATERIAL AND METHODS A retrospective analysis of all interventional treatments for portal vein stenosis in pediatric patients at a single institution from 2010 to 2021 was conducted. Platelet count, spleen size and portal vein flow velocity were assessed during the follow-up period. Primary and primary assisted patency time were determined. RESULTS A total of ten children (median age 28.5 months, interquartile range (IQR): 2.75-52.5 months) with portal vein stenosis after Mesorex-Shunt (n = 4), liver transplantation (n = 3) and other etiologies (n = 3) underwent 15 interventional procedures. There were five reinterventions and one discontinued intervention. The technical success rate was 93.3% (14/15) and clinical success of treated patients was 100% (14/14). Median follow-up was 18 months (IQR: 13.5-81 months). The median primary patency time for stent placement was 70 months (IQR: 13.5-127.25 months). For balloon angioplasty, the median primary patency time was 9 months (IQR 7.25-11.5 months), while the median assisted primary patency time was 14 months (IQR: 12 to 15 months). Platelet count, spleen size and portal vein flow velocity reliably corresponded to recurrence of portal vein stenosis in asymptomatic patients during follow-up. CONCLUSION Interventional treatment is a safe and efficient method to treat portal vein stenosis with long patency times, regardless of etiology. Primary stent placement shows a higher primary patency time than balloon angioplasty. Implementation of stent placement as the primary interventional method may improve patency times and reduce the need for repeat reinterventions in pediatric patients.
Collapse
Affiliation(s)
- Patrick Ghibes
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Staße 3, 72076, Tuebingen, Germany.
| | - Gerd Grözinger
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Staße 3, 72076, Tuebingen, Germany
| | - Steffen Hartleif
- Department of Pediatric Gastroenterology and Hepatology, University Children's Hospital Tuebingen, Tuebingen, Germany
| | - Ekkehard Sturm
- Department of Pediatric Gastroenterology and Hepatology, University Children's Hospital Tuebingen, Tuebingen, Germany
| | - Gerald M Hefferman
- Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA
| | - Silvio Nadalin
- Department of General, Visceral, and Transplant Surgery, University Hospital Tuebingen, Tuebingen, Germany
| | - Ilias Tsiflikas
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Staße 3, 72076, Tuebingen, Germany
| | - Jürgen F Schäfer
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Staße 3, 72076, Tuebingen, Germany
| | - Christoph Artzner
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Staße 3, 72076, Tuebingen, Germany
- Department of Radiology, Diakonie-Klinikum Stuttgart, Stuttgart, Germany
| |
Collapse
|
28
|
Devarajan A, Rossitto CP, Al-Kawaz M, Giovanni B, Vasan V, Shigematsu T, Berenstein A, Fifi JT. Transvenous balloon-assisted approach to anterior fossa dural arteriovenous fistula using retrograde pressure cooker technique. J Neurointerv Surg 2023:jnis-2023-020530. [PMID: 37500480 DOI: 10.1136/jnis-2023-020530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 07/12/2023] [Indexed: 07/29/2023]
Abstract
Endovascular embolization is the first-line therapy for dural arteriovenous fistulas (dAVFs). Transarterial embolization (TAE) may be limited by poor anatomical access. Transvenous embolization avoids this, but carries a risk of hemorrhage, venous redirection, and neurologic deterioration. Dual-lumen balloon microcatheters like the Scepter Mini (Microvention, Aliso Viejo, CA, USA) provide flow arrest and prevent reflux during TAE with liquid embolic agents (LEAs), but use in the distensible veins may be challenging. In this video, we use a Scepter Mini in a transvenous approach to a Cognard type IV anterior ethmoidal dAVF as a safe alternative to surgery, transvenous pressure cooker, and trans-ophthalmic TAE (video 1). The Scepter Mini was navigated transvenously to the anterior superior sagittal sinus. LEA was injected with excellent penetration to the venous pouch and further penetration into the network of tortuous feeders. No neurologic complications were experienced, and follow-up angiogram 9 months later demonstrated cure of the dAVF. Video 2 describes procedural considerations in transvenous approaches, steps of the procedure, and includes references1-10 which are relevant to this topic.neurintsurg;jnis-2023-020530v1/V1F1V1Video 1 neurintsurg;jnis-2023-020530v1/V2F2V2Video 2 .
Collapse
Affiliation(s)
- Alex Devarajan
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Christina P Rossitto
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Mais Al-Kawaz
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Brian Giovanni
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Vikram Vasan
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Tomoyoshi Shigematsu
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Alejandro Berenstein
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Johanna T Fifi
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
29
|
Su X, Gao Z, Ma Y, Song Z, Zhang H, Zhang P, Ye M. Transarterial embolization for anterior cranial fossa dural arteriovenous fistulas: a retrospective single-center study. J Neurointerv Surg 2023:jnis-2023-020408. [PMID: 37438103 DOI: 10.1136/jnis-2023-020408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 06/27/2023] [Indexed: 07/14/2023]
Abstract
BACKGROUND Clip ligation of anterior cranial fossa (ACF) dural arteriovenous fistulas (DAVFs) is the traditionally accepted first-line treatment. Endovascular treatment for ACF DAVFs may achieve good outcomes as endovascular techniques advance. Here we report the clinical and angiographic outcomes in patients with ACF DAVFs who underwent transarterial embolization (TAE) as first-line treatment. METHODS Over a 20-year period, 87.0% (40/46) of patients received TAE as first-line treatment. The clinical presentation, angiographic features, treatment strategy, and clinical and angiographic outcomes are described in this article. RESULTS Forty patients underwent TAE as first-line treatment. There were 36 men and 4 women, with a mean age of 55.6 (55.6±7.4) years. A total of 64 embolization attempts were performed. The middle meningeal artery (66.7%, 12/18) and the ophthalmic artery (54.2%, 13/24) were the most frequently used arterial access routes for complete embolization. The second option was the sphenopalatine artery (46.7%, 7/15). Complications, that is, retinal ischemia, occurred in one patient (2.5%). The total immediate complete occlusion rate for TAE was 82.5% (33/40). Two patients needed surgery for incomplete embolization. When followed up (90%, 36/40), one patient (2.8%, 1/36) reported worsening symptoms due to retinal ischemia following TAE. Although fewer than 50% of the patients received digital subtraction angiography follow-up, there were no recurrences. CONCLUSIONS We show that TAE is safe and effective in the treatment of ACF DAVFs in this study of 40 patients, making it a viable alternative to surgical ligation and transvenous embolization. More research is needed to compare these various treatment modalities.
Collapse
Affiliation(s)
- Xin Su
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
| | - Zhenzhong Gao
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
- Department of Neurosurgery, The First Affiliated Hospital of Hainan Medical University, Haikou, Hainan, China
| | - Yongjie Ma
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
| | - Zihao Song
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
| | - Hongqi Zhang
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
| | - Peng Zhang
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
| | - Ming Ye
- Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, Beijing, China
| |
Collapse
|
30
|
O'Neil LM, Pollaers K, Sale P, Vijayasekaran S, Herbert H. The utility of balloon dilation for piriform aperture stenosis - A first line surgical treatment. Int J Pediatr Otorhinolaryngol 2023; 171:111654. [PMID: 37467582 DOI: 10.1016/j.ijporl.2023.111654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/02/2023] [Accepted: 07/09/2023] [Indexed: 07/21/2023]
Abstract
AIM Describe the long-term outcomes of patients with piriform aperture stenosis managed with balloon dilation. METHODS Review of current literature. A retrospective case series of 6 patients with piriform aperture stenosis initially managed with balloon dilation at a tertiary paediatric hospital. RESULTS Six neonates diagnosed with piriform aperture were managed with balloon dilation under general anaesthesia after failing conservative treatment. Average age at first dilation was 28 days old (range 6-54). The piriform aperture was an average width of 5.15 mm, with a 4-6.5 mm range, as measured on axial CT scan. The average width at 25% of the nasal cavity, 50% and 75% was 7.7 mm, 9.3 mm and 9.98 mm respectively. Four neonates required only a single balloon dilation - two of these were stented post-operatively. The remaining two neonates required multiple balloon dilations with eventual drill-out through a sublabial approach. There was a trend of smaller piriform and nasal cavity diameters in those who required multiple procedures. The mean follow-up was 30 months. CONCLUSION Balloon dilation should be considered for primary operative management in neonates with piriform aperture stenosis who fail medical interventions. Balloon dilation can treat the narrowing at and beyond the piriform aperture. Patients who require more than one dilation are more likely to have a smaller piriform aperture and may need a drill-out procedure. The impact of nasal stents on outcomes is unclear.
Collapse
Affiliation(s)
- Luke M O'Neil
- Department of Otolaryngology, Perth Children's Hospital, Perth, Australia. Luke.O'
| | - Katherine Pollaers
- Department of Otolaryngology, Perth Children's Hospital, Perth, Australia
| | - Phillip Sale
- Department of Otolaryngology, Perth Children's Hospital, Perth, Australia; University of Western Australia, Perth, Australia
| | - Shyan Vijayasekaran
- Department of Otolaryngology, Perth Children's Hospital, Perth, Australia; University of Western Australia, Perth, Australia
| | - Hayley Herbert
- Department of Otolaryngology, Perth Children's Hospital, Perth, Australia; University of Western Australia, Perth, Australia
| |
Collapse
|
31
|
Her AY, Kim B, Ahn SH, Park Y, Cho JR, Jeong YH, Shin ES. Long-Term Clinical Outcomes of Drug-Coated Balloon Treatment for De Novo Coronary Lesions. Yonsei Med J 2023; 64:359-365. [PMID: 37226562 DOI: 10.3349/ymj.2022.0633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/21/2023] [Accepted: 04/24/2023] [Indexed: 05/26/2023] Open
Abstract
PURPOSE Data are limited on the long-term efficacy and safety of drug-coated balloon (DCB) treatment in comparison to drug-eluting stent (DES) for de novo coronary lesions. We investigated the long-term clinical outcomes of DCB treatment in percutaneous coronary intervention (PCI) for de novo coronary lesions. MATERIALS AND METHODS A total of 103 patients scheduled for elective PCI for de novo non-small coronary lesions (≥2.5 mm) who were successfully treated with DCB alone were retrospectively compared with 103 propensity-matched patients treated with second-generation DES from the PTRG-DES registry (n=13160). All patients were followed for 5 years. The primary endpoint was major adverse cardiac events [MACE; cardiac death, myocardial infarction, stroke, target lesion thrombosis, target vessel revascularization (TVR), and major bleeding] at 5 years. RESULTS At 5-year clinical follow-up, Kaplan-Meier estimates of the rate of MACE were significantly lower in the DCB group [2.9% vs. 10.7%; hazard ratio (HR): 0.26; 95% confidence interval (CI): 0.07-0.96; log-rank p=0.027]. There was a significantly lower incidence of TVR in the DCB group (1.0% vs. 7.8%; HR: 0.12; 95% CI: 0.01-0.98; long-rank p=0.015), and there was major bleeding only in the DES group (0.0% vs. 1.9%; log-rank p=0.156). CONCLUSION At 5-year follow-up, DCB treatment was significantly associated with reduced incidences of MACE and TVR, compared with DES implantation, for de novo coronary lesions.
Collapse
Affiliation(s)
- Ae-Young Her
- Division of Cardiology, Department of Internal Medicine, Kangwon National University College of Medicine, Kangwon National University School of Medicine, Chuncheon, Korea
| | - Bitna Kim
- Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| | - Soe Hee Ahn
- Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
| | - Yongwhi Park
- Department of Internal Medicine, Gyeongsang National University School of Medicine and Cardiovascular Center, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Jung Rae Cho
- Cardiology Division, Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Young-Hoon Jeong
- CAU Thrombosis and Biomarker Center, Chung-Ang University Gwangmyeong Hospital and Department of Internal Medicine, Chung-Ang University College of Medicine, Gwangmyeong, Korea
| | - Eun-Seok Shin
- Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea.
| |
Collapse
|
32
|
Bordignon S, My I, Tohoku S, Rillig A, Schaack D, Chen S, Reißmann B, Urbanek L, Hirokami J, Efe T, Ebrahimi R, Butt M, Ouyang F, Chun JKR, Metzner A, Schmidt B. Efficacy and safety in patients treated with a novel radiofrequency balloon: a two centres experience from the AURORA collaboration. Europace 2023; 25:euad106. [PMID: 37116126 PMCID: PMC10228597 DOI: 10.1093/europace/euad106] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 03/03/2023] [Indexed: 04/30/2023] Open
Abstract
AIMS A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.
Collapse
Affiliation(s)
- Stefano Bordignon
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Ilaria My
- Universitäres Herz- und Gefäßzentrum - Klinik für Kardiologie - Universitätsklinikum Hamburg-Eppendorf, Germany
| | - Shota Tohoku
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Andreas Rillig
- Medizinische Klinik 3 - Universitätsklinikum der Goethe Universität, Frankfurt, Germany
| | - David Schaack
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Shaojie Chen
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Bruno Reißmann
- Medizinische Klinik 3 - Universitätsklinikum der Goethe Universität, Frankfurt, Germany
| | - Lukas Urbanek
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Jun Hirokami
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Tolga Efe
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Ramin Ebrahimi
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Mahi Butt
- Universitäres Herz- und Gefäßzentrum - Klinik für Kardiologie - Universitätsklinikum Hamburg-Eppendorf, Germany
| | - Feifan Ouyang
- Universitäres Herz- und Gefäßzentrum - Klinik für Kardiologie - Universitätsklinikum Hamburg-Eppendorf, Germany
| | - Julian K R Chun
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Andreas Metzner
- Universitäres Herz- und Gefäßzentrum - Klinik für Kardiologie - Universitätsklinikum Hamburg-Eppendorf, Germany
| | - Boris Schmidt
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
- Medizinische Klinik 3 - Universitätsklinikum der Goethe Universität, Frankfurt, Germany
| |
Collapse
|
33
|
Delmon R, Vendeuvre T, Pries P, Aubert K, Germaneau A, Severyns M. Percutaneous balloon calcaneoplasty versus open reduction and internal fixation (ORIF) for intraarticular SANDERS 2B calcaneal fracture: Comparison of primary stability using a finite element method. Injury 2023:S0020-1383(23)00272-3. [PMID: 36997362 DOI: 10.1016/j.injury.2023.03.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/25/2023] [Accepted: 03/13/2023] [Indexed: 04/01/2023]
Abstract
INTRODUCTION Fractures of the calcaneus are common, with 65% being intra-articular, which can lead to a major impairment of the patient's quality of life. Open reduction and internal fixation with locking plates can be considered as gold-standard technique but has a high rate of post-operative complications. Minimally invasive calcaneoplasty combined with minimally invasive screw osteosynthesis is largely drawn from the management of depressed lumbar or tibial plateau fractures. The hypothesis of this study is that calcaneoplasty associated with minimally invasive percutaneous screw osteosynthesis presents biomechanical characteristics comparable with conventional osteosynthesis. MATERIALS AND METHODS Eight hind feet were collected. A SANDERS 2B fracture was reproduced on each specimen, while four calcanei were reduced by a balloon calcaneoplasty method and fixed with a lateral screw, four others were manually reduced and fixed with conventional osteosynthesis. Each calcaneus was then segmented for 3D finite element modeling. A vertical load was applied to the joint surface in order to measure the displacement fields and the stress distribution according to the type of osteosynthesis. RESULTS Analyses of the intra-articular displacement fields showed lower overall displacements in calcaneal joints treated with calcaneoplasty and lateral screw fixation. Better stress distribution was found in the calcaneoplasty group with lower equivalent joint stresses. These results could be explained by the role of the PMMA cement as a strut, enabling better load transfer. CONCLUSION Balloon Calcaneoplasty combined with lateral screw osteosynthesis has biomechanical characteristics at least comparable to locking plate fixation in the treatment of SANDERS 2B calcaneal joint fractures in terms of displacement fields and stress distribution under the premise of anatomical reduction.
Collapse
Affiliation(s)
- Romain Delmon
- Orthopedic and Traumatology department, University Hospital of Poitiers, Poitiers, France
| | - Tanguy Vendeuvre
- Orthopedic and Traumatology department, University Hospital of Poitiers, Poitiers, France; Pprime Institut UPR 3346, CNRS - University of Poitiers - ENSMA, Poitiers, France
| | - Pierre Pries
- Orthopedic and Traumatology department, University Hospital of Poitiers, Poitiers, France
| | - Kevin Aubert
- Pprime Institut UPR 3346, CNRS - University of Poitiers - ENSMA, Poitiers, France
| | - Arnaud Germaneau
- Pprime Institut UPR 3346, CNRS - University of Poitiers - ENSMA, Poitiers, France
| | - Mathieu Severyns
- Orthopedic and traumatology department, Clinique Porte Océane, Les Sables d'Olonne, France.
| |
Collapse
|
34
|
Clarençon F, Parat D, Shotar E, Premat K, Lenck S, Drir M, Maillart E, Boch AL, Sourour N. ' Balloon pressure technique' for endovascular treatment of spinal cord arteriovenous fistulas: preliminary results in 10 cases. J Neurointerv Surg 2023; 15:276-282. [PMID: 35483910 DOI: 10.1136/neurintsurg-2022-018807] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 04/14/2022] [Indexed: 01/20/2023]
Abstract
BACKGROUND Spinal arteriovenous fistulas (SAVFs) are challenging lesions to treat by endovascular means. Our purpose was to report our early experience with dual lumen balloons (DLBs) for embolization of SAVFs using ethylene vinyl alcohol (EVOH) (the so-called 'balloon pressure technique' (BPT)). MATERIALS AND METHODS During the inclusion period, 10 consecutive patients (nine men, mean age 61.6 years) underwent endovascular treatment of a SAVF (seven dural SAVFs and three epidural SAVFs) at a single institution using the BPT. DLBs were used in all cases. In seven cases (70%), a regular DLB was used, while in three cases (30%), low profile DLBs were used. EVOH was used as the liquid embolic agent in all cases. Technical and clinical complications were systematically recorded. Clinical and angiographic outcomes were systematically evaluated more than 3 months after the procedure. RESULTS Complete cure of the SAVF by endovascular means alone was obtained in 80% of cases (8/10). For the two patients with incomplete SAVF occlusion, surgery was successfully performed secondarily. No recurrence was found at the 3 month follow-up in the eight patients for whom complete occlusion was obtained at the end of the embolization procedure. No permanent clinical complication was recorded using the BPT. Clinical improvement was observed in 6/10 (60%) cases. CONCLUSION BPT was a feasible technique, with regular or low profile DLBs, for embolization of SAVFs. Our preliminary results suggest the safety and effectiveness of this technique.
Collapse
Affiliation(s)
- Frédéric Clarençon
- Interventional Neuroradiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| | - Damien Parat
- Interventional Neuroradiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| | - Eimad Shotar
- Interventional Neuroradiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| | - Kévin Premat
- Interventional Neuroradiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| | - Stéphanie Lenck
- Interventional Neuroradiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| | - Mehdi Drir
- Anesthesiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| | - Elisabeth Maillart
- Neurology, APHP-Sorbonne University, Pitié-Salpêtrière Hospital, Paris, Île-de-France, France
| | - Anne-Laure Boch
- Neurosurgery, APHP-Sorbonne University, Pitié-Salpêtrière Hospital, Paris, France
| | - Nader Sourour
- Interventional Neuroradiology, APHP-Sorbonne University. Pitié-Salpêtrière Hospital, Paris, France
| |
Collapse
|
35
|
de Vaan MDT, Croll DMR, Verhoeven CJM, de Boer MA, Jozwiak M, Ten Eikelder MLG, Mol BW, Bloemenkamp KWM, de Heus R. The influence of various induction methods on adverse outcomes in small for gestational age neonates: A secondary analysis of the PROBAAT 1 and 2 trials. Eur J Obstet Gynecol Reprod Biol 2023; 282:89-93. [PMID: 36701821 DOI: 10.1016/j.ejogrb.2023.01.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 12/30/2022] [Accepted: 01/03/2023] [Indexed: 01/06/2023]
Abstract
OBJECTIVE To evaluate the safety aspects of different induction methods in pregnancies with small-for-gestational-age neonates. STUDY DESIGN This was a secondary analysis of two previously reported multicenter, randomized controlled trials conducted in the Netherlands. In the original trials, women were randomized to either a 30 cc Foley catheter, vaginal prostaglandin E2 (PROBAAT-1) or oral misoprostol (PROBAAT-2). A total of 425 patients with a term, singleton pregnancy in cephalic presentation with an indication for labor induction and a small-for-gestational-age neonate were included in this secondary analysis. Our primary outcome was a composed adverse neonatal outcome of Apgar score < 7 after 5 min and/or a pH in the umbilical artery < 7.05 and/or NICU admission. Secondary outcomes were mode of birth, operative birth for fetal distress and pH < 7.10 in the umbilical artery. For these outcome measures, multivariate as well as bivariate analyses were performed. RESULTS An adverse neonatal outcome occurred in 4.7 % (10/214) induction with a Foley catheter, versus 12.8 % (19/149) after misoprostol (RR 0.36; 95 % CI 0.17-0.76) and 4.7 % (3/64) after Prostaglandin E2 (RR 0.98; 95 %CI 0.28-3.51). For individual components of the composed outcome of adverse events, a difference was found between a Foley catheter and misoprostol for Apgar score < 7 at 5 min (0.5 % versus 3.4; RR 0.14; 95 %CI 0.02-1.16) and NICU admission (1.9 % versus 6.1 %; RR 0.31; 0.10-0.97). No differences were found for mode of birth. CONCLUSIONS For women who gave birth to a small-for-gestational-age neonate, a Foley catheter is probably a safer induction method compared to oral misoprostol.
Collapse
Affiliation(s)
- Marieke D T de Vaan
- Jeroen Bosch Hospital, Department of Obstetrics and Gynaecology, 's-Hertogenbosch, the Netherlands; Rotterdam University of Applied Sciences, Department of Health Care Studies, Division Master Physician Assistant, Rotterdam, the Netherlands.
| | - Dorothée M R Croll
- Wilhelmina Children's Hospital Birth Centre, University Medical Centre Utrecht, Division Woman and Baby, Utrecht, the Netherlands
| | - Corine J M Verhoeven
- Amsterdam UMC, Location VUmc, Midwifery Science, AVAG/APH research institute, Amsterdam, the Netherlands; University of Nottingham, Division of Midwifery, School of Health Sciences, Nottingham, UK
| | - Marjon A de Boer
- Amsterdam UMC, VU Medical Center, Department of Obstetrics, Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | - Marta Jozwiak
- Erasmus Medical Centre, Department of Gynaecologic Oncology, Rotterdam, the Netherlands
| | - Mieke L G Ten Eikelder
- Radboud University Medical Centre, Department of Obstetrics and Gynaecology, Nijmegen, the Netherlands
| | - Ben Willem Mol
- Monash University, Department of Obstetrics and Gynaecology, Melbourne, Australia; Aberdeen Centre for Women's Health Research, University of Aberdeen, Aberdeen, UK
| | - Kitty W M Bloemenkamp
- Wilhelmina Children's Hospital Birth Centre, University Medical Centre Utrecht, Division Woman and Baby, Utrecht, the Netherlands
| | - Roel de Heus
- Wilhelmina Children's Hospital Birth Centre, University Medical Centre Utrecht, Division Woman and Baby, Utrecht, the Netherlands; St. Antonius Hospital, Department of Obstetrics and Gynaecology, Utrecht, the Netherlands
| |
Collapse
|
36
|
Matsoukas S, Rossitto CP, Berenstein A, Fifi JT. Infantile dural sinus malformation: curative embolization in two stages with the Scepter mini balloon microcatheter. J Neurointerv Surg 2023; 15:97-98. [PMID: 35428741 DOI: 10.1136/neurintsurg-2021-018608] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 04/06/2022] [Indexed: 12/16/2022]
Abstract
Endovascular embolization is the mainstay for treatment of infantile dural sinus malformations.1 2 Distal access and flow control are limiting factors in controlled embolization.3-6 The Scepter mini catheter (Microvention, Aliso Viejo, California, USA) is a low-profile, dual-lumen balloon microcatheter designed to provide navigability in small-caliber, tortuous intracranial vessels. In this technical video, we demonstrate the staged embolization of a dural sinus malformation with multiple arteriovenous fistulae using the Scepter mini catheter (video 1). In the newborn patient, embolizations were performed through the parietal branches of the left and right middle meningeal arteries. The catheter easily navigated into the small feeding arteries. No neurological complications occurred due to the procedures. Post-embolization injections demonstrated significant flow reduction into the malformation. Three-month follow-up angiography illustrated resolution of the previously dilated left transverse sinus. Complete obliteration of the dural sinus malformation was achieved in the newborn patient. neurintsurg;15/1/97/V1F1V1Video 1Curative embolization in two stages with the Scepter mini balloon microcatheter. ΑP, anteroposterior; CCA, common carotid artery.
Collapse
Affiliation(s)
- Stavros Matsoukas
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Christina P Rossitto
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Alejandro Berenstein
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Johanna T Fifi
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
37
|
Cuong NN, Linh LT, My TTT, Hoa TQ, Long H, Hoan L, Inoue M. Management of chyluria using percutaneous thoracic duct stenting. CVIR Endovasc 2022; 5:54. [PMID: 36260143 PMCID: PMC9582170 DOI: 10.1186/s42155-022-00333-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 10/14/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Thoracic duct stenosis or obstruction is one of the causes of chyluria. Although the diagnosis of chyluria is not difficult, treatment is still challenging. Although there have been no standard guidelines for the treatment of chyluria, interventional techniques now offer minimally invasive treatment options for chyluria such as interstitial lymphatic embolization, ductoplasty with balloon, or thoracic duct stenting. CASE PRESENTATION : Here, we report a case of chyluria due to obstruction of the junction between the thoracic duct and subclavian vein in a 64 -year- old female patient. The patient was treated with balloon plasty for lymphovenous junction obstruction and interstitial lymphatic embolization for chyluria. However, chyluria was recurrent after 6 months so intranodal lymphangiography was performed. Anterograde thoracic duct was accessed through a transabdominal to the cisterna chyli which showed that the thoracic venous junction was re-obstruction. The patient was successfully treated by placing a uncovered drug-eluting stent with the size of 2.5 mm x 15 mm in length for resolving the thoracic occlusion. CONCLUSION This report demonstrates the feasibility of using thoracic duct stenting in the treatment chyluria due to lymphovenous junction obstruction.
Collapse
Affiliation(s)
- Nguyen Ngoc Cuong
- grid.488446.2Diagnostic Imaging and Interventional Center, Hanoi Medical University Hospital, No1, Tonthattung, Dongda Hanoi, Vietnam
| | - Le Tuan Linh
- grid.488446.2Diagnostic Imaging and Interventional Center, Hanoi Medical University Hospital, No1, Tonthattung, Dongda Hanoi, Vietnam
| | - Thieu Thi Tra My
- grid.488446.2Diagnostic Imaging and Interventional Center, Hanoi Medical University Hospital, No1, Tonthattung, Dongda Hanoi, Vietnam
| | - Tran Quoc Hoa
- Surgery of Urology Department, Hanoi Medical University Hospital, Hanoi Medical University, Hanoi, Vietnam
| | - Hoang Long
- Surgery of Urology Department, Hanoi Medical University Hospital, Hanoi Medical University, Hanoi, Vietnam
| | - Le Hoan
- grid.488446.2Respiratory Department, Hanoi Medical University Hospital, Hanoi, Vietnam
| | - Masanori Inoue
- grid.26091.3c0000 0004 1936 9959Keio University, Tokyo, Japan
| |
Collapse
|
38
|
Feler J, Hagan MJ, Shaaya E, Anderson M, Poggi J, Chuck C, Bajaj A, Moldovan K, McTaggart RA, Haas RA, Jayaraman MV, Torabi R. Safety of Sheathless Transradial Balloon Guide Catheter Placement for Acute Stroke Thrombectomy. World Neurosurg 2022; 165:e235-41. [PMID: 35691519 DOI: 10.1016/j.wneu.2022.06.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 06/02/2022] [Accepted: 06/02/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Transradial access has been described for mechanical thrombectomy in acute stroke, and proximal balloon occlusion has been shown to improve recanalization and outcomes. However, sheathed access requires a larger total catheter diameter at the access site. We aimed to characterize the safety of sheathless transradial balloon guide catheter use in acute stroke intervention. METHODS Consecutive patients who underwent sheathless right-sided transradial access for thrombectomy with a balloon guide catheter were identified in a prospectively collected dataset from 2019 to 2021. Demographics, procedure details, and short-term outcomes were collected and reported with descriptive statistics. RESULTS A total of 48 patients (20 women) with a mean age of 72.3 years were identified. Of patients, 56.3% had occlusions in the left-sided circulation; 35 (72.9%) had M1 occlusions, 7 (14.6%) had M2 occlusions, and 6 (12.5%) had internal carotid artery occlusions. Tissue plasminogen activator was administered to 16 (33.3%) patients. Five (10.4%) patients underwent intraprocedural carotid stenting. The cohort had successful reperfusion after a median of 1 (interquartile range: 1, 2) pass. Median time from access to recanalization was 31 (interquartile range: 25, 53) minutes. A postprocedural Thrombolysis In Cerebral Infarction score of ≥2b was achieved in 46 (95.8%) patients. Five patients had wrist access site hematomas. All hematomas resolved with warm compresses, and no further intervention was required. CONCLUSIONS Sheathless radial access using a balloon guide catheter may be safely performed for acute ischemic stroke with excellent radiographic outcomes. Further investigation is warranted to evaluate the comparative effectiveness of sheathless compared with sheathed transradial balloon guide access.
Collapse
|
39
|
Parizadeh D, Vasconcelos AHC, Miller DA, Fermo OP, Huynh TJ. Dual microcatheter and coil/ balloon pressure cooker technique for transvenous embolization of cerebrospinal fluid-venous fistulas. J Neurointerv Surg 2022; 15:614. [PMID: 35705358 DOI: 10.1136/neurintsurg-2022-019005] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 06/01/2022] [Indexed: 11/03/2022]
Abstract
Cerebrospinal fluid-venous fistula is increasingly recognized as a cause of spontaneous intracranial hypotension.1 Transvenous embolization is emerging as an efficacious minimally invasive treatment.2-4 The procedure aims to embolize paraspinal and foraminal veins draining the fistula; however, complete embolization may be challenging as numerous small venous tributaries at the foraminal venous plexus, including dorsal muscular branches, may serve as additional routes of cerebrospinal fluid egress.5 To ensure curative embolization, we adopted a dual microcatheter pressure cooker technique, previously used for treatment of brain arteriovenous malformations.6 This allows improved control of embolic material reflux and greater chance of complete embolization of the site of the fistula and all potential venous tributaries. Video 1 demonstrates this technique employed in a typical case using Onyx (Medtronic, Minnesota, USA) to embolize a cerebrospinal fluid-venous fistula at the left L1 neural foramen.neurintsurg;neurintsurg-2022-019005v1/V1F1V1Video 1Disclaimer: this video summarises a scientific article published by BMJ Publishing Group Limited (BMJ). The content of this video has not been peer-reviewed and does not constitute medical advice. Any opinions expressed are solely those of the contributors. Viewers should be aware that professionals in the field may have different opinions. BMJ does not endorse any opinions expressed or recommendations discussed. Viewers should not use the content of the video as the basis for any medical treatment. BMJ disclaims all liability and responsibility arising from any reliance placed on the content.
Collapse
Affiliation(s)
- Donna Parizadeh
- Department of Radiology, Mayo Clinic, Jacksonville, Florida, USA
| | | | - David A Miller
- Department of Radiology, Mayo Clinic, Jacksonville, Florida, USA
| | - Olga P Fermo
- Department of Neurology, Mayo Clinic, Jacksonville, Florida, USA
| | - Thien J Huynh
- Department of Radiology, Mayo Clinic, Jacksonville, Florida, USA
| |
Collapse
|
40
|
Miyachi S. Carotid Angioplasty and Stenting for Occlusive Diseases. Adv Tech Stand Neurosurg 2022; 44:209-223. [PMID: 35107681 DOI: 10.1007/978-3-030-87649-4_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Stenting for carotid artery stenosis (CAS) was once denied 15 years ago because it failed to prove the non-inferiority to carotid endarterectomy (CEA). However, it is now reevaluated and is thought better due to higher safety and efficacy thanks to the development of devices, strategies, and various protection methods. To achieve the safe CAS, protection methods and stents should be properly selected based on the vessel course and plaque components on the preoperative plaque images. Particularly multiple protection methods including proximal balloon protection and double-layer micromesh stents are useful for the cases with high-risk and fragile plaque. Perioperative anti-platelet management and the control of blood pressure are also important to avoid the ischemic complications and hyperperfusion. Properly protected and tailored CAS based on the risk management has dramatically improved the clinical results and contributed to extend the indication for more difficult lesions.
Collapse
Affiliation(s)
- Shigeru Miyachi
- Department of Neurological Surgery, Aichi Medical University, Nagakute, Japan.
| |
Collapse
|
41
|
Katsanos K, Spiliopoulos S, Teichgräber U, Kitrou P, Del Giudice C, Björkman P, Bisdas T, de Boer S, Krokidis M, Karnabatidis D. Editor's Choice - Risk of Major Amputation Following Application of Paclitaxel Coated Balloons in the Lower Limb Arteries: A Systematic Review and Meta-Analysis of Randomised Controlled Trials. Eur J Vasc Endovasc Surg 2022; 63:60-71. [PMID: 34326002 DOI: 10.1016/j.ejvs.2021.05.027] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 05/15/2021] [Accepted: 05/23/2021] [Indexed: 02/05/2023]
Abstract
OBJECTIVE There have been concerns about the long term safety of paclitaxel coated devices in the lower limbs. A formal systematic review and meta-analysis of randomised controlled trials (RCTs) was performed to examine the long term risk of major amputation using paclitaxel coated balloons in peripheral arterial disease (PAD). METHOD This systematic review was registered with PROSPERO (ID 227761). A broad bibliographic search was performed for RCTs investigating paclitaxel coated balloons in the peripheral arteries (femoropopliteal and infrapopliteal) for treatment of intermittent claudication or critical limb ischaemia (CLI). The literature search was last updated on 20 February 2021 without any restrictions on publication language, date, or status. Major amputations were analysed with time to event methods employing one and two stage models. Sensitivity and subgroup analyses, combinatorial meta-analysis, and a multivariable dose response meta-analysis to examine presence of a biological gradient were also performed. RESULTS In all, 21 RCTs with 3 760 lower limbs were analysed (52% intermittent claudication and 48% CLI; median follow up two years). There were 87 major amputations of 2 216 limbs in the paclitaxel arms (4.0% crude risk) compared with 41 major amputations in 1 544 limbs in the control arms (2.7% crude risk). The risk of major amputation was significantly higher for paclitaxel coated balloons with a hazard ratio (HR) of 1.66 (95% CI 1.14 - 2.42; p = .008, one stage stratified Cox model). The prediction interval was 95% CI 1.10 - 2.46 (two stage model). The observed amputation risk was consistent for both femoropopliteal (p = .055) and infrapopliteal (p = .055) vessels. Number needed to harm was 35 for CLI. There was good evidence of a significant non-linear dose response relationship with accelerated risk per cumulative paclitaxel dose (chi square model p = .007). There was no evidence of publication bias (p = .80) and no significant statistical heterogeneity between studies (I2 = 0%, p = .77). Results were stable across sensitivity analyses (different models and subgroups based on anatomy and clinical indication and excluding unpublished trials). There were no influential single trials. Level of certainty in evidence was downrated from high to moderate because of sparse events in some studies. CONCLUSION There appears to be heightened risk of major amputation after use of paclitaxel coated balloons in the peripheral arteries. Further investigations are warranted urgently.
Collapse
Affiliation(s)
| | | | - Ulf Teichgräber
- University Hospital Jena, Friedrich-Schiller-University, Jena, Germany
| | | | | | | | | | - Sanne de Boer
- Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Miltiadis Krokidis
- Areteion Hospital, National and Kapodistrian University of Athens, Greece; Inselspital Bern University Hospital, University of Bern, Switzerland
| | | |
Collapse
|
42
|
Amoozgar H, Nouri N, Shabanpourhaghighi S, Bagherian N, Mehdizadegan N, Edraki MR, Naghshzan A, Mohammadi H, Ajami G, Abdollahi A. Effect of coarctation of aorta anatomy and balloon profile on the outcome of balloon angioplasty in infantile coarctation. BMC Cardiovasc Disord 2021; 21:594. [PMID: 34911460 PMCID: PMC8672566 DOI: 10.1186/s12872-021-02396-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 11/22/2021] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE Coarctation of the Aorta (CoA) is a relatively common cardiovascular disorder. The present study aimed to evaluate the effect of COA anatomy and high versus low-pressure balloons on the outcome of balloon angioplasty among neonates and infants. METHODS In this retrospective study, the neonates and infants undergoing balloon angioplasty at Namazi hospital were enrolled. After balloon angioplasty, immediate data results were promptly recorded.Moreover, midterm echocardiographic information was collected via electronic cardiac records of pediatric wards and clinical and echocardiographic data at least 12 months after balloon angioplasty. Finally, data were analyzed using SPSS-20. RESULTS In this study, 42 infants were included. The median age at the time of balloon angioplasty was 1.55 (range 0.1-12) months and 66.7% of the patients were male. The mean pressure gradient of coarctation was 38.49 ± 24.97 mmHg, which decreased to 7.61 ± 8.00 mmHg (P < 0.001). A high-pressure balloon was used in 27, and a low-pressure balloon was used in 15 patients. COA's pressure gradient changed 30.89 ± 18.06 in the high-pressure group and 24.53 ± 20.79 in the low-pressure balloon group (P = 0.282). In the high-pressure balloon group, 14.81% and in the low-pressure group, 33.33% had recoarctation and need second balloon angioplasty (p < 0.021). The infant with discrete coarctation had a higher decrease in gradient and lower recoarctation. CONCLUSION Recoarctation rate was lower in the high-pressure balloon. The infant with discrete COA had a better response to the balloon with more decrease in gradient and lower recoarctation rate. Therefore, the stenotic segment anatomy needs to be considered in the selection of treatment methods.
Collapse
Affiliation(s)
- Hamid Amoozgar
- Neonatal Research Center, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
- Pediatric Department, School of Medicine, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Narjes Nouri
- Pediatric Department, School of Medicine, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | | | - Neda Bagherian
- School of Medicine, Shiraz University of Medical Sciences, Jahrom, Iran
| | - Nima Mehdizadegan
- Pediatric Department, School of Medicine, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.
- The Cardiovascular Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Mohammad Reza Edraki
- Neonatal Research Center, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Amir Naghshzan
- Pediatric Department, School of Medicine, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hamid Mohammadi
- Pediatric Department, School of Medicine, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Gholamhossein Ajami
- Pediatric Department, School of Medicine, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Ashkan Abdollahi
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
43
|
Cañas-Galvis MA, Lince-Varela R, Díaz-Medina LH, Correa R, Restrepo D. Recoartación de la aorta en pacientes sometidos a angioplastia percutánea con o sin implantación de stent. Arch Cardiol Mex 2021; 91:444-452. [PMID: 34852190 PMCID: PMC8641448 DOI: 10.24875/acm.20000339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objetivo: La coartación de la aorta puede ser tratada quirúrgicamente o con angioplastia con balón. El objetivo de nuestro estudio fue describir los resultados postangioplastia percutánea con balón con o sin implantación de stent para coartación de la aorta y establecer la incidencia de recoartación en el seguimiento. Método: Estudio de cohorte, se incluyeron pacientes de cualquier edad en un periodo de seguimiento de nueve años. Resultados: Se incluyeron 89 pacientes, un 69.0% hombres. La media de seguimiento para todos los participantes fue de 33.66 meses. Al 32.5% se les implantó un stent en angioplastia; de los cuales el 24.1% se recoartaron durante el seguimiento. En el grupo sin stent se recoartaron un 36.6%. No hubo diferencia significativa en las curvas de supervivencia de los dos grupos (p = 0.889). Conclusiones: La implantación de stent durante la angioplastia con balón para tratar coartación de aorta no influyó en la incidencia de recoartación de la aorta; pero factores como la hipertensión arterial preangioplastia y el gradiente final de angioplastia > 20 mmHg se asoció con recoartación de la aorta.
Collapse
Affiliation(s)
| | | | - Luis H Díaz-Medina
- Servicio de Cardiología Pediátrica, Clínica CardioVID. Medellín, Colombia
| | - Rafael Correa
- Servicio de Cardiología Pediátrica, Clínica CardioVID. Medellín, Colombia
| | - Diana Restrepo
- Servicio de Cardiología Pediátrica, Clínica CardioVID. Medellín, Colombia
| |
Collapse
|
44
|
Li Z, Chen Y, Zeng X, Stephen S, Li Y, Li H, Dong L, He T, Zhang S, Yang P, Jiang W, Fan H. Clinical and hemodynamic insights into the use of internal iliac artery balloon occlusion as a prophylactic technique for treating postpartum hemorrhage. J Biomech 2021; 129:110827. [PMID: 34736088 DOI: 10.1016/j.jbiomech.2021.110827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 09/02/2021] [Accepted: 10/16/2021] [Indexed: 11/19/2022]
Abstract
Recently, the effectiveness of internal iliac artery balloon occlusion (IIABO) for treating postpartum hemorrhage caused by pernicious placenta previa (PPP) has been questioned. We conducted a retrospective analysis and hemodynamic simulation to assess the IIABO's effectiveness. The retrospective analysis involved 480 patients with PPP, among which 288 underwent IIABO treatment and the remaining 192 were used as controls. Blood loss and preoperative indicators were recorded, and multiple regression analysis was applied to test the effect of preoperative indicators on blood loss. Hemorrhage mechanisms were simulated using a numerical model. Results suggested that no significant difference in blood loss (1836 ± 1440 ml vs. 1784 ± 1647 ml, p = 0.22) was observed between the two groups. In addition, preoperative indicators, including age, weight, gestational age, gravidity, parity, blood type, anemia, or diabetes, were not associated with blood loss. In the simulation, after the intra-iliac artery was blocked, blood loss was caused by a reversed flow in the intrapelvic arteries, uterine veins, and uterine venules. The ratio of the time-averaged hemorrhage velocity (TAHV) in the balloon group to that in the control group was lower than that obtained in a clinical study (13.0% vs. 88.9%); in the presence of collateral circulation, blood loss occurred from collateral circulation and uterine venules after IIABO intervention, and the TAHV was 60%-90% that of the control group, which was closer to the clinical results (88.9%). These results suggest that IIABO cannot effectively treat postpartum hemorrhage because of the collateral circulation and reversed flow in the uterine venules.
Collapse
Affiliation(s)
- Zhongyou Li
- Department of Applied Mechanics, Sichuan University, Chengdu 610065, China
| | - Yu Chen
- Department of Applied Mechanics, Sichuan University, Chengdu 610065, China; Medical Big Data Center, Sichuan University, Chengdu 610041, China.
| | - Xiaoxi Zeng
- Medical Big Data Center, Sichuan University, Chengdu 610041, China
| | - Salerno Stephen
- Department of Biostatistics, University of Michigan, Ann Arbor, MI, USA
| | - Yi Li
- Department of Biostatistics, University of Michigan, Ann Arbor, MI, USA
| | - Huafeng Li
- West China Second Hospital, Sichuan University, Chengdu 610041, China.
| | - Lihua Dong
- Department of Anatomy, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
| | - Teng He
- Department of Applied Mechanics, Sichuan University, Chengdu 610065, China
| | - Shihong Zhang
- West China Second Hospital, Sichuan University, Chengdu 610041, China
| | - Pei Yang
- West China Second Hospital, Sichuan University, Chengdu 610041, China
| | - Wentao Jiang
- Department of Applied Mechanics, Sichuan University, Chengdu 610065, China
| | - Haidong Fan
- Department of Applied Mechanics, Sichuan University, Chengdu 610065, China
| |
Collapse
|
45
|
Jareczek FJ, Padmanaban V, Church EW, Simon SD, Cockroft KM, Wilkinson DA. Balloon-Assisted Roadmap Technique to Enable Flow Diversion of a High-Flow Direct Carotid-Cavernous Fistula. J Stroke Cerebrovasc Dis 2021; 31:106180. [PMID: 34823090 DOI: 10.1016/j.jstrokecerebrovasdis.2021.106180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 10/06/2021] [Accepted: 10/15/2021] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The use of flow diverters as a first-line treatment for direct carotid cavernous fistula (CCF) is a relatively new approach in the neurointerventional field which allows obliteration of the fistula with less mass effect from coils in the cavernous sinus. Safe and successful deployment of a flow diverter requires adequate imaging of the parent vessel, which may be challenging in the setting of high-flow CCF without antegrade flow. OBJECTIVE To facilitate adequate parent vessel imaging in the setting of high-flow CCF to enable the safe development of a flow diverter device. METHODS Here we present the case of a patient with delayed presentation of post-traumatic direct CCF after a motor vehicle accident, with no antegrade flow past the fistulous connection. We used temporary balloon occlusion of the fistulous connection to enable road-map imaging of the parent vessel and flow-diverter placement. "Drag and drop" device opening in the middle cerebral artery facilitated better deployment of the flow-diverter against retrograde cavernous flow through the fistula. RESULTS Temporary balloon occlusion of the fistulous connection was used to acquire a roadmap to facilitate safe deployment of a flow diverter and subsequent treatment of the CCF with transvenous coil embolization, with complete resolution of symptoms. CONCLUSION Balloon-assisted roadmap use is a novel means of visualizing the parent vessel in direct CCF to facilitate safe flow diverter deployment.
Collapse
Affiliation(s)
- Francis J Jareczek
- Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA
| | - Varun Padmanaban
- Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA
| | - Ephraim W Church
- Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA
| | - Scott D Simon
- Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA
| | - Kevin M Cockroft
- Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA
| | - D Andrew Wilkinson
- Penn State Health Milton S. Hershey Medical Center, Department of Neurosurgery, 500 University Dr. Hershey, PA, 17033, USA.
| |
Collapse
|
46
|
Nkobetchou M, Korb D, Giral E, Renevier B, Sibony O. Cervical ripening for a singleton fetus in breech prensentation at term: Comparison between mechanical and pharmaceutical methods. J Gynecol Obstet Hum Reprod 2021; 51:102258. [PMID: 34695622 DOI: 10.1016/j.jogoh.2021.102258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 10/10/2021] [Accepted: 10/18/2021] [Indexed: 10/20/2022]
Abstract
Although various international professional societies currently recommend trial of vaginal delivery of term fetuses in breech presentation, the question of the method of cervical ripening, when necessary, remains open. OBJECTIVE To compare the effectiveness of two methods of cervical ripening for delivery of a singleton fetus in breech presentation at term: a mechanical method (balloon catheter) and a pharmaceutical method (prostaglandins). STUDY DESIGN This two-center retrospective study reviewed records from 2014 through 2019 in two French maternity units with two different cervical ripening methods for fetuses in breech presentation. The study included all women with cervical ripening for a medical indication with a live singleton fetus in breech presentation ≥ 37 weeks, with an unfavorable cervix. The group treated with a mechanical method was compared with the group receiving a pharmaceutical method. The cesarean delivery rate was the principal outcome, and maternal and neonatal morbidity the secondary outcomes. RESULTS We included 74 women, 19 with mechanical cervical ripening, and 55 with pharmaceutical treatment. The cesarean rate was 57.9% in the balloon catheter group and 40% in the prostaglandin group (P = 0.097) (crude OR =2.06, 95% CI [0.72 - 5.94]; adjusted OR = 2.88, 95% confidence interval [0.52-15.96]), and the postpartum hemorrhage rates 21.1% and 1.8% respectively (P = 0.008). Neonatal morbidity did not differ significantly. CONCLUSION Although the cesarean rate and neonatal morbidity and mortality did not differ significantly between these two methods of cervical ripening, our study lacked power.
Collapse
Affiliation(s)
- Maëlys Nkobetchou
- Department of Obstetrics and Gynecology, Robert Debré Hospital, APHP, Paris, France.
| | - Diane Korb
- Department of Obstetrics and Gynecology, Robert Debré Hospital, APHP, Paris, France; Université de Paris, Centre for Epidemiology and Statistics Sorbonne Paris Cité (CRESS), Obstetrical Perinatal and Pediatric Epidemiology Research Team, EPOPE, INSERM, INRA, Paris, France
| | - Emilie Giral
- Department of Obstetrics and Gynecology, André Grégoire Hospital, Montreuil, France
| | - Bruno Renevier
- Department of Obstetrics and Gynecology, André Grégoire Hospital, Montreuil, France
| | - Olivier Sibony
- Department of Obstetrics and Gynecology, Robert Debré Hospital, APHP, Paris, France
| |
Collapse
|
47
|
Yang S, Li S, Hou L, He J. Excimer laser atherectomy combined with drug-coated balloon versus drug-eluting balloon angioplasty for the treatment of infrapopliteal arterial revascularization in ischemic diabetic foot: 24-month outcomes. Lasers Med Sci 2021; 37:1531-1537. [PMID: 34647190 DOI: 10.1007/s10103-021-03393-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 07/29/2021] [Indexed: 11/29/2022]
Abstract
There are few studies on excimer laser (308 nm) atherectomy in the treatment of infrapopliteal artery disease. The purpose of this retrospective clinical study was to assess the efficacy and safety of excimer laser atherectomy (ELA) in combination with adjuvant drug-coated balloon angioplasty (DCB) compared to DCB for infrapopliteal arterial revascularization in patients with ischemic diabetic foot. From September 2018 to February 2019, a total of 79 patients with diabetic foot were treated for infrapopliteal arterial revascularization at Tianjin First Central Hospital (Tianjin, China). In this project, 35 patients were treated with ELA combined with DCB angioplasty, and 44 patients were treated with DCB angioplasty. The patients' baseline characteristics were similar between the 2 groups. The primary efficacy endpoints through 24 months were clinically driven target lesion revascularization (CD-TLR), wound healing rate, major amputation rate, and target vessel patency rate. The primary safety endpoint through 24 months was all-cause mortality. The primary efficacy results at 24 months of ELA + DCB versus DCB were CD-TLR of 14.3% versus 34.1% (p = 0.044), wound healing rate of 88.6% versus 65.9% (p = 0.019), target vessel patency rate of 80.0% versus 52.3% (p = 0.010), and major amputations rate of 5.7% versus 22.7% (p = 0.036). The safety signal at 24 months of all-cause mortality rate was 2.9% for ELA + DCB group and 4.5% for DCB group (p = 0.957). ELA combined with DCB angioplasty is more effective than DCB in the treatment of infrapopliteal artery disease in patients with ischemic diabetic foot, which can improve the wound healing rate and target vessel patency rate. There was no statistical difference in the safety results between the two groups.
Collapse
Affiliation(s)
- Sen Yang
- Department of Vascular Surgery, Tianjin First Central Hospital, Tianjin, 300192, People's Republic of China.
| | - Shengyu Li
- Department of Vascular Surgery, Tianjin First Central Hospital, Tianjin, 300192, People's Republic of China
| | - Likun Hou
- Department of Vascular Surgery, Tianjin First Central Hospital, Tianjin, 300192, People's Republic of China
| | - Ju He
- Department of Vascular Surgery, Tianjin First Central Hospital, Tianjin, 300192, People's Republic of China
| |
Collapse
|
48
|
Khorasanizadeh M, Salih M, Harris D, Ogilvy CS. Technique to "Trap" a Segment of the Middle Meningeal Artery for Embolization of a Carotid Cavernous Fistula: 2-Dimensional Operative Video. Oper Neurosurg (Hagerstown) 2021; 21:E444. [PMID: 34332506 DOI: 10.1093/ons/opab273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 06/03/2021] [Indexed: 11/14/2022] Open
Abstract
Transvenous embolization is the favored treatment for indirect carotid-cavernous fistulas (CCFs). However, transarterial embolization can be used as an alternative method when the venous route is inaccessible. We present the case of a 47-yr-old woman with a history of diplopia, headaches, and sixth cranial nerve (CN-VI) palsy who presented with acute worsening of headache and ophthalmoplegia and rise of intraocular pressures. Angiography demonstrated a left indirect CCF (dural arteriovenous malformation) with multiple arterial feeders from the internal carotid artery as well as the middle meningeal artery (MMA) (Barrow type D). Transvenous approach was attempted first but was unsuccessful due to difficult access to the cavernous sinus. Thus, transarterial embolization through the MMA feeding branches was planned. To avoid occluding distal branches of the MMA by Onyx, we coiled it distally. In addition, we used a scepter balloon proximally to prevent the reflux of Onyx into potential collaterals to cranial nerves from proximal MMA. After trapping a segment of the MMA, Onyx was injected into the CCF fistula through the small MMA feeders. A postembolization arteriogram showed obliteration of the CCF. The patient developed mild left facial nerve paresis on the first postoperative day (thought to be related to partial embolization of tiny arteries in the facial canal), which was resolving in the course of hospitalization. She remained neurologically stable, and was discharged on the third postoperative day. To the best of our knowledge, this is the first report of transarterial embolization of CCF by distal coiling and proximal ballooning to trap a segment of an artery. The authors hereby confirm that informed consent was obtained from the patient after thorough discussion of the procedure's rationale, risks, benefits, and alternatives.
Collapse
Affiliation(s)
- MirHojjat Khorasanizadeh
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Mira Salih
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Dominic Harris
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Christopher S Ogilvy
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
49
|
Hofmeyr GJ, Dalmacio R. Novel side by side Foley catheter balloons for 'extended labour induction': Concept, simulation study and clinical application. Eur J Obstet Gynecol Reprod Biol 2021; 266:133-137. [PMID: 34634672 DOI: 10.1016/j.ejogrb.2021.09.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To introduce the concept of extended or prolonged mechanical balloon labour induction as opposed to pharmacological methods and amniotomy after single balloon expulsion, by the novel use of side-by-side Foley catheter balloons. This method is of particular relevance when there is prior uterine surgery, fetal reserve is uncertain, the risk of vertical infection is high, or facilities for labour monitoring are limited. STUDY DESIGN We conducted simulation studies to compare balloon circumferences and resistance to passage through a simulation cervix between different gauge, fluid distension volume and number of Foley catheters. We describe an illustrative clinical case. RESULTS In simulation studies we found modest increases in Foley catheter balloon circumference with increased catheter gauge and with increasing volume of distending fluid. We found that retention of Foley balloon(s) by a flexible simulated cervix was increased with the gauge, distending volume and number of balloons used side-by-side. We describe the case of a mother with pre-eclampsia with severe features and compromised fetal reserve in whom the side-by-side balloon method achieved spontaneous delivery after a single balloon had been expelled without labour commencing. CONCLUSIONS Institutional protocols for Balloon labour inductions should take into account the characteristics of locally-available balloon catheters. Further research is justified to determine the usefulness of extended mechanical labour induction with side-by-side balloon catheters, particularly with prior caesarean section, uncertain fetal reserve and settings with limited fetal monitoring capacity.
Collapse
Affiliation(s)
- G Justus Hofmeyr
- Department of Obstetrics and Gynaecology, University of Botswana, Gaborone, Botswana; Effective Care Research Unit, Universities of the Witwatersrand, Fort Hare and Walter Sisulu and Eastern Cape Department of Health, East London, South Africa
| | - Riche Dalmacio
- Department of Obstetrics and Gynaecology, Frere Hospital, Eastern Cape Department of Health and Walter Sisulu University, East London, South Africa
| |
Collapse
|
50
|
Rahinj GB, Chauhan HS, Sirivella ML, Satyanarayana MV, Ramanan L. Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening. Cardiovasc Eng Technol 2021; 13:247-264. [PMID: 34431035 DOI: 10.1007/s13239-021-00573-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 07/30/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Stenting is the most common intervention for arteriosclerosis treatment; however, the success of the treatment depends on the incidence of in-stent restenosis (ISR). Stent deployment characteristics are major influencers of ISR and can be measured in terms of dogboning, asymmetry, and foreshortening. This study aimed to analyse the implications of balloon and stent-catheter assembly parameters on the stent deployment characteristics. METHODS Experimental approach to analyse the impact of the balloon and stent-catheter assembly parameters on stent deployment characteristics is a time-consuming and complex task, whereas numerical methods prove to be quick, efficient, and reliable. In this study, eleven finite element models were employed to analyse non-uniform balloon stent expansion pattern, comprised of variation in, stent axial position on balloon, balloon length, balloon folding pattern, and balloon wall thickness. RESULTS Obtained results suggest that the axially noncentral position of the stent on balloon and variable balloon thickness lead to non-uniform stent deployment pattern. Also, it was proved that variation in balloon length and balloon folding pattern influence deployment process. CONCLUSION Improved positional accuracies, uniform balloon wall thickness, and selection of the appropriate length of a balloon for selected stent configuration will help to minimize dogboning, asymmetry, and foreshortening during non-uniform stent expansion, thereby reducing the risk of restenosis. The stated numerical approach will be helpful to optimize stent catheter assembly parameters thus minimizing in-vitro tests and product development time.
Collapse
Affiliation(s)
- Ganesh B Rahinj
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India.
| | - Harshit S Chauhan
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| | - Martin L Sirivella
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| | - Menta V Satyanarayana
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| | - Laxminarayanan Ramanan
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| |
Collapse
|