1
|
Zhou S, Sun H, Dong J, Lu P, Deng L, Liu Y, Yang M, Huo D, Hou C. Highly sensitive and facile microRNA detection based on target triggered exponential rolling-circle amplification coupling with CRISPR/Cas12a. Anal Chim Acta 2023; 1265:341278. [PMID: 37230569 DOI: 10.1016/j.aca.2023.341278] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 03/28/2023] [Accepted: 04/24/2023] [Indexed: 05/27/2023]
Abstract
MicroRNAs (miRNAs) play a crucial role in the regulation of gene expression and have been implicated in many diseases. Herein, we develop a target triggered exponential rolling-circle amplification coupling with CRISPR/Cas12a (T-ERCA/Cas12a) system, which can achieve the ultrasensitive detection with simple operation and no annealing procedure. In this assay, T-ERCA combines the exponential amplification with rolling-circle amplification by introducing a dumb-bell probe with two enzyme recognition sites. miRNA-155 targets are activators that trigger exponential rolling circle amplification to produce large amounts of ssDNA, which is then recognized by CRISPR/Cas12a for further amplification. Compared with single EXPAR or RCA combined with CRISPR/Cas12a, this assay shows higher amplification efficiency. Therefore, benefiting from the excellent amplification effect of T-ERCA and the high recognition specificity of CRISPR/Cas12a, the proposed strategy shows a wide detection range from 1 fM to 5 nM with a LOD (limit of detection) down to 0.31 fM. Moreover, it shows good application ability for assessing miRNA levels in different cells, indicating that the T-ERCA/Cas12a may provide a new guidance for molecular diagnosis and clinical practical application.
Collapse
Affiliation(s)
- Shiying Zhou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China.
| | - Human Sun
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Jiangbo Dong
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Peng Lu
- Chongqing University Three Gorges Hospital, Chongqing, 404000, PR China
| | - Liyuan Deng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Yin Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Mei Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, PR China.
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; National Facility for Translational Medicine, Shanghai Jiao Tong University, Shanghai, 200240, PR China.
| |
Collapse
|
2
|
Niu C, Liu J, Xing X, Zhang C. CRISPR-Cas12a-assisted elimination of the non-specific signal from non-specific amplification in the Exponential Amplification Reaction. Anal Chim Acta 2023; 1251:340998. [PMID: 36925288 DOI: 10.1016/j.aca.2023.340998] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/13/2023] [Accepted: 02/21/2023] [Indexed: 02/24/2023]
Abstract
Non-specific amplification is a major problem in nucleic acid amplification resulting in false-positive results, especially for exponential amplification reactions (EXPAR). Although efforts were made to suppress the influence of non-specific amplification, such as chemical blocking of the template's 3'-ends and sequence-independent weakening of template-template interactions, it is still a common problem in many conventional EXPAR reactions. In this study, we propose a novel strategy to eliminate the non-specific signal from non-specific amplification by integrating the CRISPR-Cas12a system into two-templates EXPAR. An EXPAR-Cas12a strategy named EXPCas was developed, where the Cas12a system acted as a filter to filter out non-specific amplificons in EXPAR, suppressing and eliminating the influence of non-specific amplification. As a result, the signal-to-background ratio was improved from 1.3 to 15.4 using this method. With microRNA-21 (miRNA-21) as a target, the detection can be finished in 40 min with a LOD of 103 fM and no non-specific amplification was observed.
Collapse
|
3
|
Zhou S, Deng L, Dong J, Lu P, Qi N, Huang Z, Yang M, Huo D, Hou C. Electrochemical detection of the p53 gene using exponential amplification reaction ( EXPAR) and CRISPR/Cas12a reactions. Mikrochim Acta 2023; 190:113. [PMID: 36869936 DOI: 10.1007/s00604-023-05642-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 12/31/2022] [Indexed: 03/05/2023]
Abstract
An improved electrochemical sensor has been developed for sensitive detection of the p53 gene based on exponential amplification reaction (EXPAR) and CRISPR/Cas12a. Restriction endonuclease BstNI is introduced to specifically identify and cleave the p53 gene, generating primers to trigger the EXPAR cascade amplification. A large number of amplified products are then obtained to enable the lateral cleavage activity of CRISPR/Cas12a. For electrochemical detection, the amplified product activates Cas12a to digest the designed block probe, which allows the signal probe to be captured by the reduced graphene oxide-modified electrode (GCE/RGO), resulting in an enhanced electrochemical signal. Notably, the signal probe is labeled with large amounts of methylene blue (MB). Compared with traditional endpoint decoration, the special signal probe effectively amplifies the electrochemical signals by a factor of about 15. Experimental results show that the electrochemical sensor exhibits wide ranges from 500 aM to 10 pM and 10 pM to 1 nM, as well as a relatively low limit detection of 0.39 fM, which is about an order of magnitude lower than that of fluorescence detection. Moreover, the proposed sensor shows reliable application capability in real human serum, indicating that this work has great prospects for the construction of a CRISPR-based ultra-sensitive detection platform.
Collapse
Affiliation(s)
- Shiying Zhou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China
| | - Liyuan Deng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China
| | - Jiangbo Dong
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China
| | - Peng Lu
- Chongqing University, Three Gorges Hospital, Chongqing, 404000, People's Republic of China
| | - Na Qi
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China
| | - Zhen Huang
- Key Laboratory of Bio-Resource and Eco-Environment of Ministry of Education, College of Life Sciences, Sichuan University, SeNA Research Institute and Szostak-CDHT Large Nucleic Acids Institute, Chengdu, 610065, People's Republic of China
| | - Mei Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China.
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing, 400044, People's Republic of China. .,Chongqing Key Laboratory of Bio-Perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, People's Republic of China.
| |
Collapse
|
4
|
Luo Z, Zhang S, Feng Q, Zhou Y, Jin L, Sun J, Chen Y, Jia K, Chu L. Target recognition initiated self-dissociation based DNA nanomachine for sensitive and accurate MicroRNA (miRNA) detection. Anal Biochem 2023; 662:115014. [PMID: 36493863 DOI: 10.1016/j.ab.2022.115014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 11/29/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022]
Abstract
As a valuable biomarker for various tumor, sensitive and reliable quantitative determination of microRNA (miRNA) is crucial for both disease diagnosis and cancer treatment. Herein, we depict a novel simple and sensitive miRNA detection approach by exploiting an elegantly designed target recognition initiated self-dissociation based DNA nanomachine. In this nanomachine, target recognition assists the formation of active DNAzyme secondary conformation, and the active DNAzyme generates a nicking site in H probe, initiating the self-assembly of H probe. With the reflexed sequences as primer, dual signal recycles are formed under the cooperation of DNA polymerase and Nb.BbvCI. Eventually, the method exhibits a high sensitivity with the limit of detection as low as 12 fM. In addition, the method is also demonstrated with a high selectivity that can distinguish one mismatched base pair. We believe the established approach can be a robust tool for the early-diagnosis of a variety of cancers and also in anticancer drug development.
Collapse
Affiliation(s)
- Zhigang Luo
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China.
| | - Shuang Zhang
- Department of Nuclear Medicine, Hospital of Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan, 610072, China.
| | - Qing Feng
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China
| | - Ya Zhou
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China
| | - Lian Jin
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China
| | - Jinqiu Sun
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China
| | - Yunfeng Chen
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China
| | - Kun Jia
- Department of Experimental Medicine, Third People's Hospital of Sichuan Province, No. 121, Jinglong Road, Longquanyi District, Chengdu, Sichuan, 610100, China
| | - Lei Chu
- Department of Dermatology, People's Hospital of Jianyang City, No.180 Yiyuan Roud, Jianyang, Chengdu, Sichuan, 641400, China.
| |
Collapse
|
5
|
Emaus MN, Anderson JL. Magnetic ionic liquids as microRNA extraction solvents and additives for the exponential amplification reaction. Anal Chim Acta 2021; 1181:338900. [PMID: 34556230 DOI: 10.1016/j.aca.2021.338900] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 07/28/2021] [Accepted: 07/30/2021] [Indexed: 12/24/2022]
Abstract
The detection of microRNAs (miRNAs) from highly complex matrices has become an area of immense interest as their characterization in biological samples has been utilized for disease diagnosis and body fluid identification. However, conventional northern blotting miRNA detection lacks the sensitivity required to detect circulating miRNAs. Additionally, polymerase chain reaction-based methods for miRNA detection require modified oligonucleotides that are difficult to design. Exponential amplification reaction (EXPAR) is an isothermal amplification method used for miRNA detection that is simple to design but suffers from non-specific amplification that masks low concentration miRNAs. Previous studies have shown that magnetic ionic liquids (MILs) are a promising alternative to traditional nucleic acid extraction methods capable of preconcentrating DNA from complex matrices. In this study, three hydrophobic magnetic ionic liquids (MILs) were investigated as EXPAR additives and miRNA extraction solvents. The addition of MIL to the EXPAR buffer decreased the background signal from non-specific amplification and increased the reaction rate. Reactions containing MIL could detect miRNA at concentration levels down to 10 aM. In comparison, reactions that did not contain MIL could not discriminate 10 fM lethal-7a (let-7a) standards from the no trigger control (NTC). All three MILs extracted miRNA from 2-fold diluted plasma, artificial urine, and artificial saliva with only a 1 min dispersion step. By integrating the miRNA-enriched MIL into the EXPAR buffer, the extraction and detection of femtomolar concentrations of miRNA required only 10 min. In contrast, conventional spin column kits require at least 20 min to isolate miRNA, indicating that a dispersive MIL-based extraction is ideal for high throughput analysis of miRNA.
Collapse
|
6
|
Wang X, Chen X, Chu C, Deng Y, Yang M, Huo D, Xu F, Hou C, Lv J. Naked-eye detection of site-specific ssRNA and ssDNA using PAMmer-assisted CRISPR/Cas9 coupling with exponential amplification reaction. Talanta 2021; 233:122554. [PMID: 34215057 DOI: 10.1016/j.talanta.2021.122554] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 05/08/2021] [Accepted: 05/24/2021] [Indexed: 12/26/2022]
Abstract
Accurate and effective detection of single-stranded nucleic acids is vital in both disease diagnosis and pathological studies. Hence, we develop a PAMmer-assisted CRISPR/Cas9 system mediated G4-EXPAR (Cas-G4EX) strategy for site-specific detection of ssRNA and ssDNA. PAMmer-assisted CRISPR/Cas9 executes the site-specific cleavage of target ssRNA or ssDNA and released product fragment with the desired sequence at the 3'-terminal. This fragment serves as a primer to activate subsequent sequence-dependent exponential amplification reaction (EXPAR). The G-rich EXPAR products assembles with hemin to form a G-Quadruplex (G4/hemin). G4/hemin catalyzes ABTS-H2O2 system with the appearance of vivid green color, realizing naked-eye analysis. Cas-G4EX integrates the superiority of CRISPR/Cas9 and EXPAR, presenting outstanding site-specific recognition and high-performance amplification efficiency. Meanwhile, the programmability of CRISPR/Cas9 system makes the proposed method become a universal detection paradigm for any ssRNA or ssDNA. Cas-G4EX assay shows the linear relationship from 250 aM to 2.5 nM for ssRNA detection with the actual LOD of 250 aM, and that ranges from 100 aM to 1 nM for ssDNA detection with the actual LOD of 100 aM. Additionally, the acceptable recoveries of 101.48%-109.61% for ssRNA and 93.25%-111.98% for ssDNA in real detection of human serum are obtained for detection of single-strand nucleic acid in real samples. Cas-G4EX also exhibits the excellent discrimination for single-base mutation of single-stranded nucleic acids. Therefore, Cas-G4EX assay provides a promising platform in the applications of molecular diagnosis and pathological analysis.
Collapse
Affiliation(s)
- Xianfeng Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Xiaolong Chen
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Chengxiang Chu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Yuanyi Deng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Mei Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China; Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, PR China.
| | - Faliang Xu
- Medical School of Chongqing University, Chongqing, 400044, PR China.
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China.
| | - Jiayi Lv
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, PR China
| |
Collapse
|
7
|
Carter JG, Orueta Iturbe L, Duprey JHA, Carter IR, Southern CD, Rana M, Whalley CM, Bosworth A, Beggs AD, Hicks MR, Tucker JHR, Dafforn TR. Ultrarapid detection of SARS-CoV-2 RNA using a reverse transcription-free exponential amplification reaction, RTF- EXPAR. Proc Natl Acad Sci U S A 2021; 118:e2100347118. [PMID: 34400545 DOI: 10.1073/pnas.2100347118] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
We report a rapid COVID-19 assay that gives a sample-to-signal time of under 10 min. The current gold-standard COVID-19 assay uses PCR, where strands of DNA are copied (amplified) many times to generate a read-out signal. However, as the virus genome is RNA, first conversion into DNA is required using reverse transcription (RT) before amplification. While just as sensitive, our assay is faster because 1) we have designed a method for generating DNA (the trigger strand) from RNA, bypassing the lengthy RT step, and 2) a quicker amplification process than PCR, called exponential amplification reaction (EXPAR), is used to amplify the trigger. This methodology could ultimately be applied to any RNA-based assay, including the detection of other infectious agents. A rapid isothermal method for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus responsible for COVID-19, is reported. The procedure uses an unprecedented reverse transcription–free (RTF) approach for converting genomic RNA into DNA. This involves the formation of an RNA/DNA heteroduplex whose selective cleavage generates a short DNA trigger strand, which is then rapidly amplified using the exponential amplification reaction (EXPAR). Deploying the RNA-to-DNA conversion and amplification stages of the RTF-EXPAR assay in a single step results in the detection, via a fluorescence read-out, of single figure copy numbers per microliter of SARS-CoV-2 RNA in under 10 min. In direct three-way comparison studies, the assay has been found to be faster than both RT-qPCR and reverse transcription loop-mediated isothermal amplification (RT-LAMP), while being just as sensitive. The assay protocol involves the use of standard laboratory equipment and is readily adaptable for the detection of other RNA-based pathogens.
Collapse
|
8
|
Abstract
The review focuses on the main factors involved in the formation of nonspecific products in isothermal nucleic acid amplification, such as mispriming, ab initio DNA synthesis, and additional activities of DNA polymerases, and discusses approaches to prevent formation of such nonspecific products in LAMP, RPA, NASBA, RCA, SDA, LSDA, NDA, and EXPAR.
Collapse
Affiliation(s)
- Nadezhda V Zyrina
- Institute of Protein Research, Russian Academy of Sciences, Pushchino, Moscow Region, 142290, Russia.,Institute of Theoretical and Experimental Biophysics, Russian Academy of Sciences, Pushchino, Moscow Region, 142290, Russia
| | - Valeriya N Antipova
- Institute of Theoretical and Experimental Biophysics, Russian Academy of Sciences, Pushchino, Moscow Region, 142290, Russia.
| |
Collapse
|
9
|
Trinh MP, Carballo JG, Adkins GB, Guo K, Zhong W. Physical and chemical template-blocking strategies in the exponential amplification reaction of circulating microRNAs. Anal Bioanal Chem 2020; 412:2399-2412. [PMID: 32072213 DOI: 10.1007/s00216-020-02496-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 01/28/2020] [Accepted: 02/06/2020] [Indexed: 01/16/2023]
Abstract
The detection of circulating miRNA through isothermal amplification wields many attractive advantages over traditional methods, such as reverse transcription RT-qPCR. However, it is challenging to control the background signal produced in the absence of target, which severely hampers applications of such methods for detecting low abundance targets in complex biological samples. In the present work, we employed both the cobalt oxyhydroxide (CoOOH) nanoflakes and the chemical modification of hexanediol to block non-specific template elongation in exponential amplification reaction (EXPAR). Adsorption by the CoOOH nanoflakes and the hexanediol modification at the 3' end effectively prevented no-target polymerization on the template itself and thus greatly improved the performance of EXPAR, detecting as low as 10 aM of several miRNA targets, including miR-16, miR-21, and miR-122, with the fluorescent DNA staining dye of SYBR Gold™. Little to no cross-reactivity was observed from the interfering strands present in 10-fold excess. Besides contributing to background reduction, the CoOOH nanoflakes strongly adsorbed nucleic acids and isolated them from a complex sample matrix, thus permitting successful detection of the target miRNA in the serum. We expect that simple but sensitive template-blocking EXPAR could be a valuable tool to help with the discovery and validation of miRNA markers in biospecimens. Graphical abstract.
Collapse
Affiliation(s)
- Michael P Trinh
- Department of Chemistry, University of California, Riverside, Riverside, CA, 92521, USA
| | - Jocelyn G Carballo
- Department of Chemistry, University of California, Riverside, Riverside, CA, 92521, USA
| | - Gary B Adkins
- Department of Chemistry, University of California, Riverside, Riverside, CA, 92521, USA
| | - Kaizhu Guo
- Department of Chemistry, University of California, Riverside, Riverside, CA, 92521, USA
| | - Wenwan Zhong
- Department of Chemistry, University of California, Riverside, Riverside, CA, 92521, USA.
| |
Collapse
|
10
|
Pan W, Yu D, Qin Y, Wu W, Lu Y, Yuan Z, Zhou J. Aligner mediated cleavage of nucleic acids for site-specific detection of single base mismatch. Talanta 2019; 201:358-63. [PMID: 31122435 DOI: 10.1016/j.talanta.2019.03.106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 03/25/2019] [Accepted: 03/30/2019] [Indexed: 01/03/2023]
Abstract
Single base mismatch can always connect with various gene-related diseases, whose determination has aroused widespread interest. So far, various methods have been developed to determine the common base mismatch. However most of them are complex, time-consuming. Herein, we report a novel method, which only need one conventional endonuclease (NEase) and achieve site-specific cleavage in a programmable way, to detect single base mismatch, termed aligner-mediated cleavage-based single base mismatch discrimination (AMCMD). The DNA aligner (DA) is in a stem-loop structure, consistent with an incomplete recognition site of NEase on its stem and a 5'-side arm complementary to the target sequence (TS). Once TS contains matched base and hybridizes with DA, the complete recognition site of NEase is formed, and the TS will be cleavaged with fast speed, while converse is not. Based on it, the method can clearly distinguish mismatched and complementary bases. Without sample pre-processing, we were able to obtain and verify all the test result in about 30 min through the polyacrylamide gel electrophoresis analysis. This endows the proposed method with a simpler advantage. Then we combined AMCMD and EXPAR to create a new method for single base mismatch discrimination, the short sequence obtained by AMCMD as a target to trigger EXPAR, with a detection limit at 1pM level. Another process with human serum underlines that AMCMD is compatible with the complex biological sample, thus it has the potentials for practical applications.
Collapse
|
11
|
Reid MS, Le XC, Zhang H. Exponential Isothermal Amplification of Nucleic Acids and Assays for Proteins, Cells, Small Molecules, and Enzyme Activities: An EXPAR Example. Angew Chem Int Ed Engl 2018; 57:11856-11866. [PMID: 29704305 DOI: 10.1002/anie.201712217] [Citation(s) in RCA: 169] [Impact Index Per Article: 28.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 02/09/2018] [Indexed: 12/30/2022]
Abstract
Isothermal exponential amplification techniques, such as strand-displacement amplification (SDA), rolling circle amplification (RCA), loop-mediated isothermal amplification (LAMP), nucleic acid sequence based amplification (NASBA), helicase-dependent amplification (HDA), and recombinase polymerase amplification (RPA), have great potential for on-site, point-of-care, and in situ assay applications. These amplification techniques eliminate the need for temperature cycling, as required for the polymerase chain reaction (PCR), while achieving comparable amplification yields. We highlight here recent advances in the exponential amplification reaction (EXPAR) for the detection of nucleic acids, proteins, enzyme activities, cells, and metal ions. The incorporation of fluorescence, colorimetric, chemiluminescence, Raman, and electrochemical approaches enables the highly sensitive detection of a variety of targets. Remaining issues, such as undesirable background amplification resulting from nonspecific template interactions, must be addressed to further improve isothermal and exponential amplification techniques.
Collapse
Affiliation(s)
- Michael S Reid
- Department of Chemistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - X Chris Le
- Department of Chemistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
- Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, 10-102 Clinical Sciences Building, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Hongquan Zhang
- Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, 10-102 Clinical Sciences Building, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| |
Collapse
|