1
|
Liu Y, Zhang L, Ren S, Chen H. A Magnetic Field Sensor Based on Directional Coupling in a Magnetic Fluid-Filled Photonic Crystal Fiber. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5805. [PMID: 37687496 PMCID: PMC10488763 DOI: 10.3390/ma16175805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Revised: 08/14/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023]
Abstract
In this paper, a dual-core photonic crystal fiber (DC-PCF) sensitivity sensor filled with magnetic liquid is introduced and investigated with the finite element method (FEM). To regulate the energy coupling involving the two cores, the magnetic fluid is filled into the pore between the two cores. To adjust the coupling between the supermodes in the DC-PCF, the refractive index (RI) of the air hole filled magnetic fluid may change due to the external magnetic field. This specifically created a magnetic fluid-filled DC-PCF; the magnetic fluid-filled hole is not used as the core for energy transmission, thus avoiding transmission loss. The dip wavelength and the magnetic field displayed an excellent linear connection between 80 and 260 Oe, depending on the numerical data. The detection sensitivity of the magnetic field reached 515.75 pm/Oe at a short fiber length of 482 µm. The designed magnetic fluid-filled DC-PCF has high sensitivity and small volume and has great application prospects in magnetic field detection in the medical and industrial fields.
Collapse
Affiliation(s)
- Yingchao Liu
- Key Laboratory of Industrial Intelligent Perception, School of Artificial Intelligence, North China University of Science and Technology, Tangshan 063210, China; (Y.L.); (L.Z.); (S.R.)
| | - Lijun Zhang
- Key Laboratory of Industrial Intelligent Perception, School of Artificial Intelligence, North China University of Science and Technology, Tangshan 063210, China; (Y.L.); (L.Z.); (S.R.)
| | - Shuang Ren
- Key Laboratory of Industrial Intelligent Perception, School of Artificial Intelligence, North China University of Science and Technology, Tangshan 063210, China; (Y.L.); (L.Z.); (S.R.)
| | - Hailiang Chen
- State Key Laboratory of Metastable Materials Science & Technology, School of Science, Yanshan University, Qinhuangdao 066004, China
- Key Laboratory for Microstructural Material Physics of Hebei Province, School of Science, Yanshan University, Qinhuangdao 066004, China
| |
Collapse
|
2
|
Liu Y, Huang Z, Wang Z, Zhang Y, Wang Z, Dong J, Zhou J, Shen C. High-sensitivity optical fiber magnetic field sensor based on multimode optical fiber multi Fabry-Perot interference cavities. OPTICS EXPRESS 2023; 31:1025-1033. [PMID: 36785138 DOI: 10.1364/oe.478367] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 12/11/2022] [Indexed: 06/18/2023]
Abstract
A high-sensitivity optical fiber magnetic field sensor based on a multi-Fabry-Perot interference (F-P) cavity in an etched multimode optical fiber (MMF) was proposed. The MMF was etched along the fiber axis and a hole with the length of about 250 µm formed in the MMF. The multi-F-P cavity in the MMF is a sandwich structure, which is composed of UV glue, magnetic fluid and UV glue. The refractive index and effective cavity length of the magnetic fluid cavity change with the changing of the external magnetic field, which will result in changes of the reflection spectra of the multi-F-P. Thus, the external magnetic field could be detected by the changes of spectra. Experimental results showed that the high magnetic field sensitivity of 299.7 pm/mT and 0.164 dB/mT were obtained in the range of 0∼8 mT weak magnetic induction intensity by using the wavelength and intensity demodulations, respectively. The proposed sensor shows the potential applications in the magnetic field measurement in the weak magnetic environment.
Collapse
|
3
|
Kumar R. Magnetic Field Sensing Using Tapered Small-Core Optical Fibre Surrounded by Different Concentrations of Magnetic Fluid. SENSORS (BASEL, SWITZERLAND) 2022; 22:8536. [PMID: 36366233 PMCID: PMC9656877 DOI: 10.3390/s22218536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/20/2022] [Accepted: 11/01/2022] [Indexed: 06/16/2023]
Abstract
In this paper, a high-sensitivity magnetic field sensor based on a single-mode-tapered small-core-single-mode (STSCS) optical fibre structure is investigated. The tapered small-core section of STSCS is surrounded by magnetic fluid (MF) containing ferromagnetic particles (FMPs) of different concentrations. The FMPs align themselves along the magnetic field, depending on the strength of the magnetic field. This alignment of FMPs changes the refractive index around the tapered small-core section, which in turn changes the output spectral response of the STSCS optical fibre structure. The change in spectral response is then calibrated for sensing the magnetic field strength. This paper also investigates the effect of both the taper waist diameter of the STSCS optical fibre structure and the concentration of MF surrounding it on the magnetic field sensitivity. The maximum sensitivity demonstrated in this paper is 0.46 nm/mT for a taper waist diameter of 10 μm surrounded by 1.22% FMPs in the MF. The magnetic sensor demonstrates reversible results, and its effects on the orientation of the magnetic field along the X-Y, X-Z and Y-Z axes are also investigated, which suggest that the sensor is capable of vector magnetic field measurement.
Collapse
Affiliation(s)
- Rahul Kumar
- Perth College, University of Highlands and Islands, Perth PH1 2NX, UK;
- Faculty of Engineering and Environment, Northumbria University, Newcastle upon Tyne NE1 8ST, UK
| |
Collapse
|
4
|
Socoliuc V, Avdeev MV, Kuncser V, Turcu R, Tombácz E, Vékás L. Ferrofluids and bio-ferrofluids: looking back and stepping forward. NANOSCALE 2022; 14:4786-4886. [PMID: 35297919 DOI: 10.1039/d1nr05841j] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Ferrofluids investigated along for about five decades are ultrastable colloidal suspensions of magnetic nanoparticles, which manifest simultaneously fluid and magnetic properties. Their magnetically controllable and tunable feature proved to be from the beginning an extremely fertile ground for a wide range of engineering applications. More recently, biocompatible ferrofluids attracted huge interest and produced a considerable increase of the applicative potential in nanomedicine, biotechnology and environmental protection. This paper offers a brief overview of the most relevant early results and a comprehensive description of recent achievements in ferrofluid synthesis, advanced characterization, as well as the governing equations of ferrohydrodynamics, the most important interfacial phenomena and the flow properties. Finally, it provides an overview of recent advances in tunable and adaptive multifunctional materials derived from ferrofluids and a detailed presentation of the recent progress of applications in the field of sensors and actuators, ferrofluid-driven assembly and manipulation, droplet technology, including droplet generation and control, mechanical actuation, liquid computing and robotics.
Collapse
Affiliation(s)
- V Socoliuc
- Romanian Academy - Timisoara Branch, Center for Fundamental and Advanced Technical Research, Laboratory of Magnetic Fluids, Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
| | - M V Avdeev
- Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna, Moscow Reg., Russia.
| | - V Kuncser
- National Institute of Materials Physics, Bucharest-Magurele, 077125, Romania
| | - Rodica Turcu
- National Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), Donat Str. 67-103, 400293 Cluj-Napoca, Romania
| | - Etelka Tombácz
- University of Szeged, Faculty of Engineering, Department of Food Engineering, Moszkvai krt. 5-7, H-6725 Szeged, Hungary.
- University of Pannonia - Soós Ernő Water Technology Research and Development Center, H-8800 Zrínyi M. str. 18, Nagykanizsa, Hungary
| | - L Vékás
- Romanian Academy - Timisoara Branch, Center for Fundamental and Advanced Technical Research, Laboratory of Magnetic Fluids, Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
- Politehnica University of Timisoara, Research Center for Complex Fluids Systems Engineering, Mihai Viteazul Ave. 1, 300222 Timisoara, Romania
| |
Collapse
|
5
|
State-of-the-Art Optical Microfiber Coupler Sensors for Physical and Biochemical Sensing Applications. BIOSENSORS-BASEL 2020; 10:bios10110179. [PMID: 33218037 PMCID: PMC7698761 DOI: 10.3390/bios10110179] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/09/2020] [Accepted: 11/16/2020] [Indexed: 11/17/2022]
Abstract
An optical fiber coupler is a simple and fundamental component for fiber optic technologies that works by reducing the fiber diameter to hundred nanometers or several micrometers. The microfiber coupler (MFC) has regained interest in optical fiber sensing in recent years. The subwavelength diameter rationales vast refractive index (RI) contrast between microfiber “core” and surrounding “cladding”, a large portion of energy transmits in the form of an evanescent wave over the fiber surface that determines the MFC ultrasensitive to local environmental changes. Consequently, MFC has the potential to develop as a sensor. With the merits of easy fabrication, low cost and compact size, numerous researches have been carried out on different microfiber coupler configurations for various sensing applications, such as refractive index (RI), temperature, humidity, magnetic field, gas, biomolecule, and so on. In this manuscript, the fabrication and operation principle of an MFC are elaborated and recent advances of MFC-based sensors for scientific and technological applications are comprehensively reviewed.
Collapse
|
6
|
Fabrication and Characterization of Seawater Temperature Sensor with Self-Calibration Based on Optical Microfiber Coupler Interferometer. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10176018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this paper, a novel high-sensitivity temperature sensor with two sensing regions based on optical microfiber coupler interferometer (OMCI) for ocean application is proposed. The OMCI sensor is constructed by connecting Faraday mirrors to the two ports of the microfiber coupler respectively. Its sensing characteristics analysis and experimental test are conducted. Using a broad-spectrum light source as input light, temperature sensor demodulation can be implemented by tracking the drift of the characteristic wavelength (dip wavelength or peak wavelength) of the reflection spectrum. Experimental results show that the temperature sensitivity of the OMCI sensor can reach 1007.4 pm/°C and the detection dynamic range up to 17.6 °C. Besides, due to the two sensing regions in OMCI, self-calibration of seawater temperature sensing and optimization of multi-parameter cross-sensitive demodulation are performed by affecting the non-equal-arm interferometer through a specific package design of the external environment. The sensor has the advantages of high sensitivity, large dynamic range, small size, easy to manufacture, which will play an important role in the practical application of marine environment monitoring.
Collapse
|
7
|
Lu L, Miao Y, Zhang H, Li B, Fei C, Zhang K. Magnetic sensor based on serial-tilted-tapered optical fiber for weak-magnetic-field measurement. APPLIED OPTICS 2020; 59:2791-2796. [PMID: 32225829 DOI: 10.1364/ao.385083] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 02/12/2020] [Indexed: 06/10/2023]
Abstract
An optical fiber magnetic field sensor based on serial-tilted-tapered fiber (STTF) integrated with magnetic fluid is proposed. The compact STTF structure consists of two closely tilted-tapered fibers with a length of approximately 836 µm, which results in stronger mode coupling. The transmission characteristics of the proposed sensor under different magnetic field intensities (MFIs) have been studied. The results show that the proposed structure has an outstanding response to MFI and that the highest sensitivity is 32.67 pm/Oe in wavelength and 0.0336 dB/Oe in transmission in the range of 0-75 Oe. The minimum resolution of the proposed sensor is up to 0.6734 Oe. These types of sensors have great potential application in weak magnetic field measurements due to their compact structure and good sensing performance.
Collapse
|
8
|
Yu Y, Chen H, Zhang Z, Chen D, Wang J, Wei Z, Yang J, Yan P. Characteristic Test Analysis of Graphene Plus Optical Microfiber Coupler Combined Device and Its Application in Fiber Lasers. SENSORS 2020; 20:s20061645. [PMID: 32188050 PMCID: PMC7146154 DOI: 10.3390/s20061645] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/10/2020] [Accepted: 03/12/2020] [Indexed: 12/05/2022]
Abstract
In this study, a graphene and optical microfiber coupler (OMC) integrated device (GOMC) was proposed and fabricated. After its characteristic analysis and testing, it was applied to the development of adjustable multi-wavelength fiber lasers. By integrating the OMC with graphene, the polarization dependence of OMC was enhanced. Meanwhile, the novel GOMC was given the capabilities of filtering, coupling, beam splitting, and polarization correlation. When the GOMC was integrated as a filter and beam splitter into the ring cavity of the fiber laser, the proposed GOMC-based fiber laser could achieve single-wavelength and multi-wavelength regulated output. The laser had a 3 dB linewidth of less than 30 pm, a signal-to-noise ratio of approximately 40 dB, and an output power fluctuation of less than 1 dB. The GOMC could also be used for the development of functional devices, such as adjustable mode lockers and mode coupling selectors, which provide an excellent experimental platform for new fiber lasers and the research of multi-dimensional light-field manipulation.
Collapse
Affiliation(s)
- Yang Yu
- Department of Physics, College of Liberal Arts and Sciences, National University of Defense Technology, Changsha 410073, China; (Z.Z.); (D.C.); (J.Y.)
- Deep Sea Technology Laboratory, College of Meteorology and Oceanology, National University of Defense Technology, Changsha 410073, China;
- Correspondence: ; Tel.: +86-186-7001-3227
| | - Hao Chen
- Shenzhen Key Lab of Laser Technology, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China; (H.C.); (P.Y.)
| | - Zhenfu Zhang
- Department of Physics, College of Liberal Arts and Sciences, National University of Defense Technology, Changsha 410073, China; (Z.Z.); (D.C.); (J.Y.)
| | - Dingbo Chen
- Department of Physics, College of Liberal Arts and Sciences, National University of Defense Technology, Changsha 410073, China; (Z.Z.); (D.C.); (J.Y.)
| | - Jianfei Wang
- Deep Sea Technology Laboratory, College of Meteorology and Oceanology, National University of Defense Technology, Changsha 410073, China;
| | - Zhengtong Wei
- Department of Basic Education, Information Engineering University, Zhengzhou 450000, China;
| | - Junbo Yang
- Department of Physics, College of Liberal Arts and Sciences, National University of Defense Technology, Changsha 410073, China; (Z.Z.); (D.C.); (J.Y.)
| | - Peiguang Yan
- Shenzhen Key Lab of Laser Technology, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China; (H.C.); (P.Y.)
| |
Collapse
|
9
|
Magnetic Field Sensor Based on a Tri-Microfiber Coupler Ring in Magnetic Fluid and a Fiber Bragg Grating. SENSORS 2019; 19:s19235100. [PMID: 31766466 PMCID: PMC6928919 DOI: 10.3390/s19235100] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 11/14/2019] [Accepted: 11/19/2019] [Indexed: 02/04/2023]
Abstract
In this paper we propose and investigate a novel magnetic field sensor based on a Tri-microfiber coupler combined with magnetic fluid and a fiber Bragg grating (FBG) in a ring. A sensitivity of 1306 pm/mT was experimentally demonstrated in the range of magnetic fields from 0 to 15 mT. The reflection peak in the output spectrum associated with the FBG serves as a reference point allowing to avoid ambiguity in determining the spectral shift induced by the magnetic field. Due to its high sensitivity at low magnetic fields, the proposed structure could be of high interest in low field biosensing applications that involve a magnetic field, such as magnetic manipulation or separation of biomolecules.
Collapse
|
10
|
Zu L, Zhang H, Miao Y, Li B, Yao J. Microfiber coupler with a Sagnac loop for water pollution detection. APPLIED OPTICS 2019; 58:5859-5864. [PMID: 31503887 DOI: 10.1364/ao.58.005859] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 06/24/2019] [Indexed: 06/10/2023]
Abstract
The measurement of chloride ion concentrations has been studied for the purpose of monitoring the quality of water resources. In this paper, a chloride ion sensor based on a microfiber coupler with a Sagnac loop is proposed. The microfiber coupler, which acts as the sensing unit and has a diameter of 10 μm and a length of 1 mm, is fabricated using the flame-brushing technique, and the two ends are connected to form a Sagnac loop, which acts as a reflector to enhance the reflection in the structure. Experimental results show that the sensitivity reaches a maximum of 423 pm/‰ and that the detection limit for the chloride ion concentration is 0.447‰ at a wavelength of 1595 nm. The proposed sensor is characterized by a simple and easy manufacturing process, compact structure, and low cost; further, this sensing unit has great potential for applications in marine chloride detection and environmental safety monitoring, especially for monitoring building corrosion and water pollution.
Collapse
|
11
|
Wei F, Liu D, Mallik AK, Farrell G, Wu Q, Peng GD, Semenova Y. Temperature-compensated magnetic field sensing with a dual-ring structure consisting of microfiber coupler-Sagnac loop and fiber Bragg grating-assisted resonant cavity. APPLIED OPTICS 2019; 58:2334-2339. [PMID: 31044931 DOI: 10.1364/ao.58.002334] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Accepted: 02/18/2019] [Indexed: 06/09/2023]
Abstract
A novel temperature-compensated magnetic field sensor based on a ring erbium-doped fiber laser combined with a fiber Bragg grating (FBG) and a Sagnac loop containing a microfiber coupler (MFC) and magnetic fluid is proposed and investigated. Thanks to the dual-ring structure of the MFC-Sagnac loop and the FBG-assisted resonant cavity, the output of the structure has two distinct laser peaks. In addition to the magnetic field sensing capability, the proposed structure can simultaneously provide temperature information. The maximum experimentally demonstrated sensitivity to a magnetic field determined from the spectral shift of one laser peak is 102 pm/mT in the magnetic field range from 0 to 60 mT. The spectral position of the other laser peak is independent of the magnetic field but shifts toward longer wavelengths with temperature with a sensitivity of 18 pm/°C. The proposed magnetic field sensor is advantageous for applications requiring measurement accuracy over a wide magnetic field range with a compensating of temperature information.
Collapse
|
12
|
Tian J, Ma Q, Yu W, Li D, Dong X, Liu G, Wang J. High pairing rate Janus-structured microfibers and array: high-efficiency conjugate electrospinning fabrication, structure analysis and co-instantaneous multifunctionality of anisotropic conduction, magnetism and enhanced red fluorescence. RSC Adv 2019; 9:10679-10692. [PMID: 35515332 PMCID: PMC9062496 DOI: 10.1039/c9ra01147a] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 03/26/2019] [Indexed: 12/19/2022] Open
Abstract
A highly efficient and convenient conjugate electrospinning technique is employed to obtain high pairing rate Janus-structured microfibers in electrospun products by optimizing the spinning conditions. In addition, a Janus-structured microfiber array rendering tri-functional performance of tunable magnetism, electrically anisotropic conduction and increased fluorescence is prepared via the same technique using a rotating device as a fiber collector. The array is composed of an ordered arrangement of Janus-structured microfibers. The extraordinary Janus structure and oriented arrangement endow the Janus-structured microfibers with excellent fluorescence. The fluorescence intensity of the Janus-structured microfiber array is, respectively, 1.21, 14.3 and 20.3 times higher than that of the Janus-structured microfiber non-array, the composite microfiber array and the composite microfiber non-array. The Janus-structured microfiber array has a similar saturation magnetization to the contradistinctive specimens. Additionally, the magnetism of the Janus-structured microfiber array can be modulated with different mass ratios of Fe3O4 nanoparticles (NPs), and the conductance ratio between the length direction and diameter direction of the Janus-structured microfibers for the array can be tuned from 103 to 106 by adding a higher percentage of polyaniline (PANI). Our new findings have established a highly efficient conjugate electrospinning technique to prepare Janus-structured microfibers of high pairing rate, and complete isolation of fluorescent material from magnetic nanoparticles and conductive material is accomplished in the Janus-structured microfibers to ensure high fluorescence intensity without a notably disadvantageous influence of dark-colored substances. More importantly, the fabrication technique for the Janus-structured microfibers can be generalized to manufacture other Janus-structured multifunctional materials. High pairing rate Janus-structured microfibers and their arrays, rendering simultaneous anisotropic conduction, magnetism and fluorescence, are successfully fabricated via conjugate electrospinning.![]()
Collapse
Affiliation(s)
- Jiao Tian
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| | - Qianli Ma
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| | - Wensheng Yu
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| | - Dan Li
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| | - Xiangting Dong
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| | - Guixia Liu
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| | - Jinxian Wang
- Key Laboratory of Applied Chemistry and Nanotechnology at Universities of Jilin Province
- Changchun University of Science and Technology
- Changchun 130022
- China
| |
Collapse
|
13
|
Wang XZ, Wang Q. A High-Birefringence Microfiber Sagnac-Interferometer Biosensor Based on the Vernier Effect. SENSORS 2018; 18:s18124114. [PMID: 30477179 PMCID: PMC6308418 DOI: 10.3390/s18124114] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 11/18/2018] [Accepted: 11/20/2018] [Indexed: 02/05/2023]
Abstract
We propose a high-sensitive Sagnac-interferometer biosensor based on theVernier effect (VE) with a high-birefringence microfiber. The sensitivity enhancement is achieved by utilizing two cascaded Sagnac interferometers. One of the two interference loops consists of a panda polarization-maintaining fiber as a filter, whilst the other is comprised of high-birefringent microfiber coated Graphene oxide (GO) as a sensing channel. We theoretically analyzed the sensitivity of the sensor and verified it with experiments. The results of the simulation show that the refractive index sensitivity is more than five times that of the fiber sensor based on a single Sagnac loop. The sensitivity of the refractive index in the experiments can reach 2429 nm/refractive index unit (RIU), which is basically in accordance with the simulation. We also use electrostatic adsorption to coat GO on the surface of the sensing channel. GO is employed to adsorb bovine serum albumin (BSA) molecules to achieve the desired detection results, which has good biocompatibility and large specific surface area. The sensitivity to detect BSA can reach 9.097 nm/(mg×mL−1).
Collapse
Affiliation(s)
- Xue-Zhou Wang
- College of Information Science and Engineering, Northeastern University, Shenyang 110819, China.
| | - Qi Wang
- College of Information Science and Engineering, Northeastern University, Shenyang 110819, China.
| |
Collapse
|
14
|
Zhang T, Zhang J, Cheng L, Liang Y, Jin L, Liang H, Guan BO. Response of an erbium-doped dual-polarization fiber laser to a perpendicular gradient magnetic field. OPTICS LETTERS 2017; 42:4675-4678. [PMID: 29140340 DOI: 10.1364/ol.42.004675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Accepted: 10/09/2017] [Indexed: 06/07/2023]
Abstract
Direct interaction between fiber lasers and a magnetic field is useful but seldom explored because fiber is known as magnetic field insensitive. In this Letter, the response of an erbium-doped dual-polarization fiber laser to a perpendicular gradient magnetic field is investigated. Measured as beat note frequency change, significant response greater than 500 MHz has been observed that is within theoretical expectation, and translates to a birefringence change of about 4×10-6 and a potentially very high response to a magnetic field of about 12.8 pT/Hz. The response can be further enhanced by increasing the gradient of the gradient magnetic field.
Collapse
|
15
|
Han YG. Investigation of Temperature Sensitivity of a Polymer-Overlaid Microfiber Mach-Zehnder Interferometer. SENSORS 2017; 17:s17102403. [PMID: 29065459 PMCID: PMC5677079 DOI: 10.3390/s17102403] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 10/12/2017] [Accepted: 10/18/2017] [Indexed: 01/21/2023]
Abstract
The temperature sensitivity of the free spectral range (FSR) for a polymer-overlaid microfiber Mach-Zehnder interferometer (MZI) is investigated both theoretically and experimentally. The waist diameter of the optical microfiber can be controlled to alter the thermal expansion and optic properties of the polymer-coated MZI. Inserting an optical microfiber with a strong evanescent field into the MZI, a low index polymer with high thermal characteristics is deposited on the surface of the microfibers to realize a polymer-overlaid microfiber MZI. It was found that the thermal expansion factor in the proposed MZI plays an important role in the temperature sensitivity of the FSR. The temperature sensitivity of the polymer-overlaid microfiber MZI is improved, which is measured to be -8.29 nm/°C at 25 °C. The optical transmission spectrum of the polymer-overlaid microfiber MZI is converted to the spatial frequency spectrum via fast Fourier transform. The temperature sensitivity of the spatial frequency in the proposed polymer-overlaid MZI is estimated to be 18.31 pm-1 °C-1, which is 17 times higher than that of the microfiber MZI without polymer coating (1.04 pm-1 °C-1).
Collapse
Affiliation(s)
- Young-Geun Han
- Department of Physics and the Research Institute for Natural Sciences, Hanyang University, Seoul 133-791, Korea.
| |
Collapse
|