1
|
Solarino G, Vicenti G, Moretti L, Abate A, Spinarelli A, Moretti B. Interprosthetic femoral fractures-A challenge of treatment. A systematic review of the literature. Injury 2014; 45:362-368. [PMID: 24119494 DOI: 10.1016/j.injury.2013.09.028] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/18/2013] [Indexed: 02/02/2023] [Imported: 04/23/2025]
Abstract
The success of prosthetic surgery has led to an increase in the percentage of the population having more than one prosthetic implant. This, combined with an increase in the average life expectancy and functional requirements for the elderly, has led to a higher incidence of periprosthetic and interprosthetic fractures. More precisely, the femoral shaft is compressed between two ipsilateral implants with most of these fractures being located on the supracondylar femoral shaft. Their treatment is not only technically demanding and challenging, but can also be associated with serious complications. Treatment must be determined and assessed according to the type of fracture, the stability of the prosthesis, the bone quality and the general condition of the patient. There is little information in the literature about this type of injury: there are several published case reports detailing unconventional solutions and the case studies presented are limited and not significant. This review aims to provide an updated and comprehensive list of diagnostic and therapeutic protocols accepted today, while recognising that these protocols are being continuously updated according to experience gained.
Collapse
|
Review |
11 |
41 |
2
|
Solarino G, Piazzolla A, Notarnicola A, Moretti L, Tafuri S, De Giorgi S, Moretti B. Long-term results of 32-mm alumina-on-alumina THA for avascular necrosis of the femoral head. J Orthop Traumatol 2012; 13:21-27. [PMID: 22249776 PMCID: PMC3284675 DOI: 10.1007/s10195-011-0174-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2010] [Accepted: 12/04/2011] [Indexed: 11/17/2022] [Imported: 04/23/2025] Open
Abstract
BACKGROUND Ceramic bearings in total hip arthroplasty (THA) have been introduced in clinical practice to minimize the problem of polyethylene particle-induced osteolysis. The aim of the study is to report the results of 68 consecutive alumina-on-alumina THAs done in 61 patients for avascular necrosis (AVN) of the femoral head. MATERIALS AND METHODS In all implants a press-fit cup was used; it was combined with a 32-mm alumina head and with titanium-alloy stems. The mean age at surgery was 50 years. At an average follow-up of 13 years two hips have been revised, one for periprosthetic infection and one for excessive abduction of the cup. RESULTS No revision for aseptic loosening is recorded; one anatomical cementless femoral stem had radiological evidence of definite aseptic loosening. No dislocations occurred, and no osteolysis was observed. CONCLUSIONS The results support the application of alumina-alumina THA for long-lasting replacements.
Collapse
|
Comparative Study |
13 |
22 |
3
|
Solarino G, Bizzoca D, Moretti AM, D’Apolito R, Moretti B, Zagra L. Sex and Gender-Related Differences in the Outcome of Total Hip Arthroplasty: A Current Concepts Review. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:1702. [PMID: 36556904 PMCID: PMC9788147 DOI: 10.3390/medicina58121702] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 10/31/2022] [Accepted: 11/18/2022] [Indexed: 11/24/2022] [Imported: 04/23/2025]
Abstract
Background and Objectives: Sex and gender-related differences may influence the outcome of patients undergoing total hip arthroplasty (THA). The present paper aims to depict the importance of sex and gender-related issues in the perioperative management of patients undergoing THA to improve clinical outcomes and prevent postoperative complications. Materials and Methods: From January 2002 to August 2022, OVID-MEDLINE, EMBASE, SCOPU S, Web of Science, Google Scholar, and PubMed were searched to identify relevant studies for further analysis. The search strategy included the following terms: (("gender-related differences" [MeSH Terms] OR "sex-related differences" [All Fields]) OR ("gender indicators" [MeSH Terms] OR "sex" [All Fields])) AND ("total hip arthroplasty" [MeSH Terms] OR (total hip replacement [All Fields])). Results: Twenty-eight papers were included in this current concepts review. Sex and gender-related differences were analyzed with regard to the following points: (1) surgical approach, robotic surgery, scar cosmesis, and implant choice; (2) postoperative clinical outcome and complications; (3) sexual activity after THA; and (4) psychological status and daily functional requirements. The data analysis showed that female patients need more specific attention in the preoperative, intraoperative, and postoperative phases to improve clinical and functional outcomes, reduce complications risk, and manage patient satisfaction. Conclusions: THA outcomes may be influenced by sex and gender-related factors which should be carefully assessed and addressed in patients undergoing surgery to improve the postoperative outcomes of patients' satisfaction and reduce postoperative complications that can differ between the two sexes.
Collapse
|
Review |
3 |
22 |
4
|
Solarino G, Piazzolla A, Mori CM, Moretti L, Patella S, Notarnicola A. Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients. BMC Musculoskelet Disord 2011; 12:32. [PMID: 21284879 PMCID: PMC3038170 DOI: 10.1186/1471-2474-12-32] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2010] [Accepted: 02/01/2011] [Indexed: 12/12/2022] [Imported: 08/29/2023] Open
Abstract
BACKGROUND Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN). The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA): implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethylene inlay can lead to more wear, osteolysis and failure of the implant. Ceramic induces less friction and minimal wear even with larger heads. METHODS A total of 35 THAs were performed for displaced intracapsular FFN, using a 32 mm alumina-alumina coupling. RESULTS At a mean follow-up of 80 months, 33 have been clinically and radiologically reviewed. None of the implants needed revision for any reason, none of the cups were considered to have failed, no dislocations nor breakage of the ceramic components were recorded. One anatomic cementless stem was radiologically loose. CONCLUSIONS On the basis of our experience, we suggest that ceramic-on-ceramic coupling offers minimal friction and wear even with large heads.
Collapse
|
research-article |
14 |
22 |
5
|
Solarino G, Zagra L, Piazzolla A, Morizio A, Vicenti G, Moretti B. Results of 200 Consecutive Ceramic-on-Ceramic Cementless Hip Arthroplasties in Patients Up To 50 Years of Age: A 5-24 Years of Follow-Up Study. J Arthroplasty 2019; 34:S232-S237. [PMID: 30777621 DOI: 10.1016/j.arth.2019.01.057] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 01/02/2019] [Accepted: 01/24/2019] [Indexed: 02/01/2023] [Imported: 04/23/2025] Open
Abstract
BACKGROUND Ceramic-on-ceramic (CoC) bearings due to their mechanical properties can be used in primary total hip arthroplasty (THA) especially in young patients requiring a long-lasting implant. The goal of this study is to analyze the results of a series of 200 consecutive CoC THAs in patients aged 50 years or less at the time of surgery. METHODS A retrospective study was conducted on the first 200 consecutive CoC arthroplasties performed using the direct lateral approach on 105 females and 81 males (14 bilateral cases) with an average age of 44.2 (16-50) years. The diagnosis was primary or post-traumatic osteoarthritis in 94 cases, avascular necrosis of the femoral head in 47, displaced intracapsular femoral neck fracture in 29, osteoarthritis secondary to developmental dysplasia of the hip/Legg-Calvè-Perthes disease/slipped capital femoral epiphysis in 20, and rheumatic diseases in 10 cases. The preoperative Harris Hip Score was 32.5 on average (range 15-55). All the implants were cementless. In 177 THAs the coupling was alumina-on-alumina, and in 23 cases the coupling was AMC-on-AMC (alumina matrix composite). RESULTS Twenty-five patients with 28 THAs were lost at the final follow-up, 2 stems were revised due to subsidence, 1 cup was revised due to malposition, 1 femoral head was changed because of impingement, and 1 THA was revised for periprosthetic infection. Three patients sustained a Vancouver B1 periprosthetic femoral fracture. At the final follow-up (mean 14.9 years; minimum 5 years to maximum 24 years), 172 THAs were eligible for clinical and radiographic evaluation: none was revised for wear and/or breakage of the ceramic components. Harris Hip Score rose up to a mean value of 90.1 (52-100). CONCLUSION The present report demonstrates that CoC coupling offers excellent long-term results in THA performed in young patients with very low wear and no adverse effects caused by the material.
Collapse
|
|
6 |
20 |
6
|
SOLARINO GIUSEPPE, ABATE ANTONELLA, VICENTI GIOVANNI, SPINARELLI ANTONIO, PIAZZOLLA ANDREA, MORETTI BIAGIO. Reducing periprosthetic joint infection: what really counts? JOINTS 2015; 3:208-214. [PMID: 26904527 PMCID: PMC4739541 DOI: 10.11138/jts/2015.3.4.208] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] [Imported: 04/23/2025]
Abstract
Periprosthetic joint infection (PJI) remains one of the most challenging complications after joint arthroplasty. Despite improvements in surgical techniques and in the use of antibiotic prophylaxis, it remains a major cause of implant failure and need for revision. PJI is associated with both human host-related and bacterial agent-related factors that can interact in all the phases of the procedure (preoperative, intraoperative and postoperative). Prevention is the first strategy to implement in order to minimize this catastrophic complication. The present review focuses on the preoperative period, and on what to do once risk factors are fully understood and have been identified.
Collapse
|
research-article |
10 |
15 |
7
|
Solarino G, Vicenti G, Abate A, Carrozzo M, Picca G, Moretti B. Mason type II and III radial head fracture in patients older than 65: is there still a place for radial head resection? Aging Clin Exp Res 2015; 27 Suppl 1:S77-S83. [PMID: 26215317 DOI: 10.1007/s40520-015-0425-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Accepted: 07/09/2015] [Indexed: 11/26/2022] [Imported: 04/23/2025]
Abstract
PURPOSE To evaluate the clinical outcomes of radial head excision for multifragmentary radial head fracture in patients over 65 years old. METHODS We retrospectively examined 30 patients over 65 years of age treated with radial head excision for comminuted radial head fractures. Patients were evaluated through clinical examinations, administrative questionnaires (DASH--Disabilities of the Arm, Shoulder and Hand; MEPS--Mayo Elbow Performance Score, VAS--Visual Analog Scale) and plain films. RESULTS The mean follow-up was 40 months (range 24-72 months); 27 out of 30 patients claimed to be satisfied. The mean DASH score was 13 (range 3-45.8) and mean MEPS was 79 (range 65-97). The radiographic evaluation showed 21 cases of elbow arthritis; only two of them complained about pain. Heterotopic ossification was evident in six cases with functional impairment in only one patient. Six patients with increased ulnar variance had clinical distal radio-ulnar joint instability. DISCUSSION Radial head excision has been considered a safe surgical procedure with satisfactory clinical outcomes. Development in biomechanical studies and prosthetic replacement of the radial head question the validity of radial head excision. In current literature, there are neither long-term follow-up studies on radial head prosthesis outcomes nor studies which consider elderly patient samples. CONCLUSION Radial head resection remains a good option when a radial head fracture occurs in elderly patients, taking into account the influence of poor bone quality and comorbidities on the outcome. Radial head excision is not indicated in the presence of associated lesions, because of the risk of residual elbow instability; complications associated with advanced age must be considered and a strict follow-up granted.
Collapse
|
|
10 |
15 |
8
|
Solarino G, Bizzoca D, Moretti L, Vicenti G, Piazzolla A, Moretti B. What's New in the Diagnosis of Periprosthetic Joint Infections: Focus on Synovial Fluid Biomarkers. Trop Med Infect Dis 2022; 7:355. [PMID: 36355897 PMCID: PMC9692966 DOI: 10.3390/tropicalmed7110355] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 10/29/2022] [Accepted: 10/31/2022] [Indexed: 08/10/2023] [Imported: 04/23/2025] Open
Abstract
Periprosthetic joint infections are some of the leading causes of revision prosthetic surgery, accounting for 25% of failed total knee replacements and 15% of failed total hip replacements. The search for a biomarker that, together with clinical and radiological findings, could improve the management of such patients is currently a significant challenge for orthopaedic surgeons. Synovial fluid is a viscous and mucinous substance produced by the synovium, a specialized connective tissue that lines diarthrodial joints. Synovial fluid is an ultrafiltrate of plasma but also contains proteins secreted from the surrounding tissues, including the articular cartilage and synovium. Therefore, synovial fluid represents a source of disease-related proteins that could be used as potential biomarkers in several articular diseases. Based on these findings, the study of synovial fluid has been gaining increasing importance in recent years. This review aims to assess the accuracy and the limitations of the most promising synovial fluid biomarkers-i.e., Alpha-Defensin, Leukocyte Esterase, C-Reactive Protein, Interleukin-6, Calprotectin, Presepsin and Neopterin-in the diagnosis of PJI. Special attention will be given to emerging synovial biomarkers, which could soon be important in diagnosing PJIs.
Collapse
|
Review |
3 |
14 |
9
|
Solarino G, Vicenti G, Carrozzo M, Ottaviani G, Moretti B, Zagra L. Modular neck stems in total hip arthroplasty: current concepts. EFORT Open Rev 2021; 6:751-758. [PMID: 34667646 PMCID: PMC8489472 DOI: 10.1302/2058-5241.6.200064] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] [Imported: 04/23/2025] Open
Abstract
Modular neck (MN) implants can restore the anatomy, especially in deformed hips such as sequelae of development dysplasia.Early designs for MN implants had problems with neck fractures and adverse local tissue, so their use was restricted to limited indications.Results of the latest generation of MN prostheses seem to demonstrate that these problems have been at least mitigated.Given the results of the studies presented in this review, surgeons might consider MN total hip arthroplasty (THA) for a narrower patient selection when a complex reconstruction is required.Long MN THA should be avoided in case of body mass index > 30, and should be used with extreme caution in association with high offset femoral necks with long or extra-long heads. Cr-Co necks should be abandoned, in favour of a titanium alloy connection.Restoring the correct anatomic femoral offset remains a challenge in THA surgeries.MN implants have been introduced to try to solve this problem. The MN design allows surgeons to choose the appropriate degree and length of the neck for desired stability and range of motion. Cite this article: EFORT Open Rev 2021;6:751-758. DOI: 10.1302/2058-5241.6.200064.
Collapse
|
Review |
4 |
11 |
10
|
Solarino G, Piconi C, De Santis V, Piazzolla A, Moretti B. Ceramic Total Knee Arthroplasty: Ready to Go? JOINTS 2017; 5:224-228. [PMID: 29270560 PMCID: PMC5738472 DOI: 10.1055/s-0037-1607428] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] [Imported: 08/29/2023]
Abstract
Total knee arthroplasty (TKA) is a well-established surgical procedure in the late stages of knee osteoarthritis. Nevertheless, this procedure is associated with a percentage of unsatisfactory results and biomechanical failures, with aseptic loosening being the most common cause of revision. Beside these problems, cutaneous and systemic hypersensitivity reactions to metals have arisen as an increasing concern after joint arthroplasties, even if allergies against implant materials are still a quite rare and not well-known problem. Ceramic composites have been recently used in prosthetic components, showing minimum wear and excellent long-term results in total hip replacement, due to their high resistance to scratching and their better wettability with respect to cobalt-chromium alloy. Furthermore, the biologic response to debris generated from these bearings is less aggressive. Knee joint simulator tests and clinical results demonstrate promising results of TKAs with ceramic components that should led to benefit for the patients.
Collapse
|
Review |
8 |
11 |
11
|
Solarino G, Scialpi L, Bruno M, De Cillis B. On a case of multifocal osteonecrosis in a patient suffering from acute lymphoblastic leukemia. LA CHIRURGIA DEGLI ORGANI DI MOVIMENTO 2008; 92:119-122. [PMID: 18473129 DOI: 10.1007/s12306-008-0047-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2008] [Accepted: 04/14/2008] [Indexed: 11/26/2022] [Imported: 08/29/2023]
Abstract
The Authors describe the case of a 14-year-old girl who developed a multifocal osteonecrosis (ON), after treatment with chemotherapy and corticosteroids for acute lymphoblastic leukemia (ALL). She came to our attention about 6 months after the beginning of treatment complaining of pain in her left knee and later in both hips and shoulders. Radiography and MRI confirmed the presence of avascular ON at all these sites. The patient underwent bilateral total hip arthroplasty, which was still functioning well at the last follow-up visits at 5 years, and at 5 years and 4 months. ON is increasingly recognized as a complication of the treatment of cancer in children and adolescents, and as patients now frequently survive ALL into adulthood, orthopedists will be increasingly called on to manage this complication affecting multiple joints in children and young adults.
Collapse
|
Case Reports |
17 |
10 |
12
|
Solarino G, Vicenti G, Abate A, Carrozzo M, Picca G, Colella A, Moretti B. Volar locking plate vs epibloc system for distal radius fractures in the elderly. Injury 2016; 47 Suppl 4:S84-S90. [PMID: 27503313 DOI: 10.1016/j.injury.2016.07.056] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] [Imported: 04/23/2025]
Abstract
PURPOSE To compare clinical outcomes of ORIF with volar locking plates and the Epibloc system (ES) in the treatment of distal radius fractures (DRFs) in patients aged over 65 years. METHODS We retrospectively examined a consecutive series of 100 patients with intra-articular or extra-articular DRF who were admitted to our Department of Orthopaedics and Traumatology between January 2007 and January 2013. Fifty patients were treated using the Epibloc System; and the other 50 patients using ORIF with volar locking plates. In all patients, functional evaluation (wrist range of motion [ROM], grip strength and Disability of the Arm, Shoulder and Hand [DASH] Score) and radiographic assessment (radial inclination, volar tilt, ulnar variance and articular congruity) were performed at 2 and 6 weeks, and 3, 6 and 12 months postoperatively; then every 12 months thereafter. RESULTS ORIF with volar locking plates was associated with better outcome than ES in the intra-articular and extra-articular DRF groups, generating higher average ROM, DASH and visual analogue scale (VAS) scores. Grip strength mean values, however, were quantified over the minimum level for a functional wrist (>60%) in both groups. There were no differences between the two techniques in X-ray parameters, and no further correlation was found with functional outcome and ROM. CONCLUSIONS In a low-functioning patient with multiple medical comorbidities, minimally-invasive surgery with the ES is a safe option, enables early mobilisation of the wrist and is likely to produce acceptable clinical outcomes.
Collapse
|
Comparative Study |
9 |
8 |
13
|
Solarino G, Bortone I, Vicenti G, Bizzoca D, Coviello M, Maccagnano G, Moretti B, D'Angelo F. Role of biomechanical assessment in rotator cuff tear repair: Arthroscopic vs mini-open approach. World J Orthop 2021; 12:991-1000. [PMID: 35036341 PMCID: PMC8696602 DOI: 10.5312/wjo.v12.i12.991] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 06/28/2021] [Accepted: 12/08/2021] [Indexed: 02/06/2023] [Imported: 08/29/2023] Open
Abstract
BACKGROUND Rotator cuff (RC) tears are one of the most frequent pathologies within the shoulder girdle. Hand dominance and older age are associated with RC tears. Two different surgical procedures, the mini-open (MO) and all-arthroscopic (AA) approach, represented the standard of treatment. AIM To compare the clinical and biomechanical outcomes of two surgical techniques (AA vs MO procedure) performed to address the painful shoulder syndrome with partial or total supraspinatus tendon tear. METHODS Eighty-eight participants, 50 following RC repair with AA and 38 with MO approach, were recruited in the present cross-sectional case-control study (ORTHO-SHOULDER, Prot. 0054602). All patients underwent postoperative clinical evaluation for pain (Visual analogic scale), impairment, and disability (disability of the arm, shoulder, and hand) and limitation in daily activity (Constant-Murley score). Patients' shoulder mobility was also assessed in our Laboratory of Functional Movement through a wearable inertial sensor and surface electromyography to monitor kinematics and muscle activity during the movement on the frontal (abduction/adduction) and sagittal (flexion-extension) planes. RESULTS No statistically significant differences between the two procedures were observed in either main clinical score or range of motion. A significant increase in velocity during the movement execution and a higher contribution of upper trapezius muscles were found in the AA group compared with MO patients. CONCLUSION In terms of clinical scores, our findings were in line with previous results. However, the use of technology-based assessment of shoulder mobility has revealed significant differences between the two techniques in terms of mean velocity and pattern of muscle activation.
Collapse
|
Case Control Study |
4 |
8 |
14
|
SOLARINO GIUSEPPE, NOTARNICOLA ANGELA, MACCAGNANO GIUSEPPE, PIAZZOLLA ANDREA, MORETTI BIAGIO. Irreducible posterolateral dislocation of the knee: a case report. JOINTS 2015; 3:91-96. [PMID: 26605258 PMCID: PMC4634811 DOI: 10.11138/jts/2015.3.2.091] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] [Imported: 04/23/2025]
Abstract
Irreducible posterolateral dislocations of the knee are rare lesions, generally caused by high-energy trauma inducing rotational stress and a posterior and lateral displacement of the tibia. In these conditions, the interposition of abundant soft tissue inside the enlarged medial joint space prevents spontaneous reduction or non-surgical treatment by manipulation of the dislocation. Surgical treatment is therefore compulsory. We report the clinical case of a woman who suffered a subluxation of the knee while jogging. The case we describe is of interest because it shows that even less severe knee dislocations, like this subluxation caused by a low-velocity sports trauma, may present in an irreducible form requiring open surgery. Clinical-instrumental monitoring did not reveal any signs of vascular or nerve injury. Owing to the irreducibility of the lesion we were obliged to perform open surgery in order to free the joint from the interposed muscle tissue and repair medial capsule-ligament lesions. Repair of the damaged cruciate ligaments was deferred to a second stage, but ultimately rendered necessary by the persistence of joint instability and the need to address the patient's functional needs. In the literature, different one- and two-step surgical options, performed by arthroscopy or arthrotomy, are reported for such related problems. The Authors discuss these various options and examine and discuss their own decision taken during the surgical work-up of this case.
Collapse
|
research-article |
10 |
8 |
15
|
Solarino G, Abate A, Morizio A, Vicenti G, Moretti B. Should we use ceramic-on-ceramic coupling with large head in total hip arthroplasty done for displaced femoral neck fracture? SEMINARS IN ARTHROPLASTY 2013; 24:255-260. [DOI: 10.1053/j.sart.2014.01.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] [Imported: 04/23/2025]
|
|
12 |
7 |
16
|
SOLARINO GIUSEPPE, SPINARELLI ANTONIO, CARROZZO MASSIMILIANO, PIAZZOLLA ANDREA, VICENTI GIOVANNI, MORETTI BIAGIO. Long-term outcome of low contact stress total knee arthroplasty with different mobile bearing designs. JOINTS 2014; 2:109-114. [PMID: 25606553 PMCID: PMC4295681 DOI: 10.11138/jts/2014.2.3.109] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] [Imported: 04/23/2025]
Abstract
PURPOSE to evaluate the differences in clinical outcome and survivorship of three different mobile bearings for total knee arthroplasty. METHODS a retrospective study was conducted in 60 patients (53 females, 7 males, mean age: 68 years and 5 months) each submitted to total knee replacement using one of the three different mobile bearings of the LCS system (Depuy Johnson & Johnson, Warsaw, IN). The diagnosis was knee osteoarthritis in 57 cases and rheumatoid arthritis in three cases. Three different groups of 20 cases each were identified: total knee arthroplasties with mobile menisci (group 1); total knee arthroplasties with the rotating platform (group 2); and total knee arthroplasties with the anteroposterior glide platform (group 3). As regards the component fixation, 33 implants were cementless, three were cemented, and in 24 only the tibial component was cemented. The patella was not replaced. RESULTS although the duration of follow-up differed between the three groups, the clinical and radiological results at final follow-up showed no revision of femoral and/or tibial components for mechanical or septic reasons, and no signs of impending failure. One meniscal bearing, showing polyethylene wear after 17 years, was successfully replaced. CONCLUSIONS the present retrospective study confirmed the long-term effectiveness of knee implants with mobile bearings, in which the congruity of the surfaces makes it possible to overcome the problem of high contact stresses that may result in polyethylene wear and osteolysis; at the same time, these implants eliminate constraint forces thereby reducing the risk of mechanical loosening. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
|
research-article |
11 |
7 |
17
|
Solarino G, Bizzoca D, Dramisino P, Vicenti G, Moretti L, Moretti B, Piazzolla A. Total hip arthroplasty following the failure of intertrochanteric nailing: First implant or salvage surgery? World J Orthop 2023; 14:763-770. [PMID: 37970621 PMCID: PMC10642404 DOI: 10.5312/wjo.v14.i10.763] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 08/16/2023] [Accepted: 09/06/2023] [Indexed: 10/16/2023] [Imported: 04/23/2025] Open
Abstract
BACKGROUND Proximal femur fractures, including both intracapsular (femoral neck fractures) and extracapsular fractures (intertrochanteric femoral fractures, IFFs), affect around 1.5 million people per year worldwide. Mechanical failures of intertrochanteric nailing in IFFs could be managed with revision total hip arthroplasty (THA). AIM To describe the surgical complexity and the procedure-related complication rates in patients with trochanteric nailing failure and treated with THA. METHODS Patients referred to our level I trauma center between April 2012 and July 2018 with failed cephalomedullary nailing following trochanteric fractures were retrospectively recruited. All patients underwent a salvage surgical procedure, i.e., cephalomedullary nail removal and conversion to THA. The same surgical and anesthesiology team performed the surgical procedures under spinal anesthesia. All patients underwent clinical and radiographic follow-ups for at least 24 mo. Complications and re-operations were recorded. RESULTS Seventy-four patients met the inclusion criteria (male: 29; female: 45; mean age: 73.8-years-old; range: 65-89) and were included in the current study. The average operative time was 117 min (76-192 min). The average blood loss was 585 mL (430-1720 mL). Among the 74 patients, 43 (58.1%) required transfusion of three or more blood units. Two patients died within the 4th d after surgery because of pulmonary embolism, and 1 patient died 9 mo after surgery due to ischemic myocardial infarction. The complication rate in the 71 patients who completed the minimum 24-mo follow-up was 22.5%. In 3 cases out of 71 (4.2%) periprosthetic acetabular fracture was observed during the follow-up. One of these periacetabular fractures occurred intraoperatively. An intraoperative periprosthetic femur fracture was observed in 5 patients out of 71 (7.0%). Four of these patients needed a re-operation to fix the fracture with plates and cerclages; in one of these patients, femoral stem revision was also necessary. In 4 patients out of 71 (5.6%), an early THA dislocation was observed, whereas in 1 case (1.4%) a late THA dislocation was observed. Three patients out of 71 (4.2%) developed a periprosthetic joint infection during the study follow-up. CONCLUSION The present study demonstrated that salvage options for IFF fixation failure are complex procedures with a relevant intraoperative and postoperative complication rate.
Collapse
|
Observational Study |
2 |
5 |
18
|
Solarino G, Piazzolla A, Moretti L, Vicenti G, Moretti B. A minimum 20-year outcome of 100 consecutive alumina-on-alumina arthroplasties performed by a single surgeon. Hip Int 2018; 28:10-14. [PMID: 30755120 DOI: 10.1177/1120700018813218] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] [Imported: 08/29/2023]
Abstract
BACKGROUND: Ceramic-on-ceramic (CoC) is currently a viable bearing combination in primary total hip arthroplasty (THA) and, due to its mechanical properties, it can be used in young patients requiring a long-lasting implant. The aim of this study is to report the results of a series of CoC THAs at a minimum 20 years follow-up. METHODS: A retrospective study was conducted on the 1st 100 consecutive alumina-on-alumina arthroplasties performed by a single surgeon on 51 females and 40 males with an average age of 60.7 years. The mean preoperative Harris Hip Score was 35. The press-fit cup consisted of a pure titanium core with a titanium alloy mesh. Both the inlay and the head were made of dense polycrystalline surgical-grade alumina. The 32-mm femoral head was anchored on 3 different femoral components. RESULTS: 19 patients with 22 THAs were died or lost, 2 anatomic cementless stems were revised due to sinking, 1 THA was revised for periprosthetic infection. 2 patients sustained a Vancouver B1 periprosthetic femoral fracture. None of the 78 THAs eligible for this study were revised for wear, breakage, noise of the ceramic components. None of the cups, none of the cemented stems, none of the cementless straight stems failed. HHS raised up to a mean value of 95. CONCLUSIONS: The present report demonstrates that CoC coupling offers minimal wear at a long-term follow-up. Further studies are needed to evaluate whether the modern ceramic composites will confirm such excellent results in total hip replacement.
Collapse
|
|
7 |
5 |
19
|
Solarino G, Carlet A, Moretti L, Miolla MP, Ottaviani G, Moretti B. Clinical Results in Posterior-Stabilized Total Knee Arthroplasty with Cementless Tibial Component in Porous Tantalum: Comparison between Monoblock and Two Pegs vs. Modular and Three Pegs. PROSTHESIS 2022; 4:160-168. [DOI: 10.3390/prosthesis4020016] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] [Imported: 04/23/2025]
Abstract
Nowadays, total knee arthroplasty (TKA) is widely considered to be the gold standard for treatment of end-stage knee osteoarthritis. Although the optimal mode of fixation in TKA continues to be an important area of investigation, cementless fixation offers the possibility to gain biologic fixation, preserve bone stock and mineral density, and potentially improve survivorship. The purpose of this retrospective study was to evaluate the clinical results of a posterior-stabilized total knee arthroplasty with cementless tibial component in porous tantalum, comparing two groups: Group A (30 patients), TKA with a monoblock component and two pegs, and Group B (22 patients), with a modular component and three pegs. Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were submitted to the patients, and radiographs were collected at the last follow-up. The mean follow-up was 26.32 (20–40) months. Significant differences were not detected between the postoperative KSS values in the two groups (p = 0.44). Evaluating KOOS outcomes, we found in Group A that the rating system showed a statistically significant improvement from a preoperative average rating of 51.4 (SD ± 15) to an average of 72.66 (SD ± 19) at final follow-up (p < 0.05). In Group B, the KOOS rating system showed a statistically significant improvement from a preoperative average rating of 48.3 (SD ± 18) to an average of 79.54 (SD ± 17) postoperatively (p < 0.05). Comparing KOOS final outcomes between groups, we found no statistically significant difference at the mean final follow-up (p = 0.20), with the exception of the sport-related section (p < 0.05). Radiological evaluation at the final follow-up did not show any sign of polyethylene wear, radiolucency, septic or aseptic loosening, or change in alignment in either group. The current study demonstrates an excellent survivorship of cementless tibial components in porous tantalum and the possibility of osseous integration, without significant differences between the two groups under investigation.
Collapse
|
|
3 |
3 |
20
|
Solarino G, Vicenti G, Piazzolla A, Maruccia F, Notarnicola A, Moretti B. Total hip arthroplasty for dysplastic coxarthrosis using a cementless Wagner Cone stem. J Orthop Traumatol 2021; 22:16. [PMID: 33864539 PMCID: PMC8053138 DOI: 10.1186/s10195-021-00578-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 04/06/2021] [Indexed: 12/24/2022] [Imported: 04/23/2025] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) is currently the best surgical option for hip osteoarthritis secondary to developmental hip dysplasia (DDH); it may be extremely challenging, because of the hypoplasic proximal metaphysis, pathological anteversion, and excessive cervico-diaphyseal angle of the neck at the femoral side. The purpose of this retrospective study was to evaluate the long-term survival and clinical and radiological results of Conus uncemented stems, implanted in patients affected by hip osteoarthritis with Crowe not-type IV secondary to DDH. MATERIAL AND METHODS We identified 100 consecutive THAs performed for DDH in 63 women and 24 men, with an average age of 53 years in a single center. Thirteen patients underwent bilateral hip replacement. The patients' mean body mass index was 29.8 kg/m2 (range 27.1-35.6 kg/m2). The main indications for surgery were severe hip pain and considerable functional impairment: the preoperative Harris Hip Score was 29.5 on average (range 22-61). Radiologically, 8 hips were classified as Crowe I, 43 hips as Crowe II, and 49 hips as Crowe III. In all cases, we implanted the Wagner femoral cone prosthesis using the direct lateral approach; in the attempt to reestablish native hip biomechanics, 66 stems were 135° and 34 were 125°. RESULTS The mean follow-up of the study was 11.7 years (range 2.2-21.8 years). Harris Hip Score increased to a mean value of 71.5 points (range 52-93 points). Radiographic evaluation demonstrated osteointegration of the implant with stable bone growth observed at the stem-endosteum interface; signs of bone readaptation and thinning of the femoral calcar were present in nine hips. None of the patients underwent revision for septic or aseptic loosening of the stem; none sustained a periprosthetic fracture. CONCLUSIONS This study confirms the theoretical advantages that suggest the choice of the Wagner cone when technical difficulties during prosthetic surgery are expected owing to abnormal proximal femoral anatomy. LEVEL OF EVIDENCE Level IV, retrospective case study.
Collapse
|
research-article |
4 |
3 |
21
|
Solarino G, Luca A, Marzo L, Scialpi L, Solarino GB. Comparison among total knee arthroplasties with a mobile bearing: menisci versus rotating platform versus AP glide platform. LA CHIRURGIA DEGLI ORGANI DI MOVIMENTO 2008; 92:79-83. [PMID: 18587627 DOI: 10.1007/s12306-008-0051-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2007] [Accepted: 12/17/2007] [Indexed: 11/26/2022] [Imported: 04/23/2025]
Abstract
A retrospective study was conducted on 60 patients (53 females, seven males with a mean age of 68 years and 5 months) who underwent a total knee replacement using a mobile bearing. The diagnosis was primary osteoarthritis in 57 cases and rheumatoid arthritis in three cases. None of the patients underwent a bilateral procedure, thus 60 implants (33 all cementless, three all cemented, 24 with only the tibial component cemented) were considered. Three different groups were identified: Group 1: first 20 total knee arthroplasties with menisci. Group 2: first 20 total knee arthroplasties with rotating platform. Group 3: first 20 total knee arthroplasties with AP glide platform. Clinical and radiological results at the final follow up, although different in time among the three groups, have shown no revision due to mechanical or septic reasons, and no signs of impending failure.
Collapse
|
Comparative Study |
17 |
2 |
22
|
Solarino G, Spinarelli A, Virgilio A, Simone F, Baglioni M, Moretti B. Outcomes of Ceramic Composite in Total Hip Replacement Bearings: A Single-Center Series. JOURNAL OF COMPOSITES SCIENCE 2021; 5:320. [DOI: 10.3390/jcs5120320] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] [Imported: 04/23/2025]
Abstract
Despite the fact that total hip replacement is one of the most successful surgical procedures for treatment of a variety of end-stage hip diseases, the process of osteolysis and implant loosening remains a significant problem, especially in young and high-demand patients. More than 40 years ago, ceramic bearings were introduced due to their mechanical advantage in order to obtain a reduction in wear debris, and due to the conviction that it was possible to minimize friction and wear owing to their mechanical hardness, high chemical stability, surface lubrication by fluids and low friction coefficient. Together with excellent mechanical properties, ceramics have a biological inertness: eventual ceramic debris will lead to a reactive response with a high predominance of fibrocystic cells, rather than macrophagic cells, and absence of giant cells, which is ideal from a biological perspective. As a consequence, they will not trigger the granulomatous reaction necessary to induce periprosthetic osteolysis, and this clearly appears to be of great clinical relevance. In recent years, tribology in manufacturing ceramic components has progressed with significant improvements, owing to the development of the latest generation of ceramic composites that allow for an increased material density and reduced grain size. Currently, ceramic-on-ceramic bearings are considered the attractive counterparts of ceramic- or metal-on-polyethylene ones for patients with a long life expectancy. The aim of this paper is to report the results of total hip replacements performed with a ceramic-on-ceramic articulation made from a ceramic composite in a single center, focusing on its usefulness in specific preoperative diagnosis.
Collapse
|
|
4 |
2 |
23
|
Solarino G, Moretti L, Vicenti G, Bizzoca D, Piazzolla A, Moretti B. Hip hemiarthroplasty with modular neck: is it useful in residents' learning curve? A prospective clinical trial. Hip Int 2020; 30:30-36. [PMID: 33267688 DOI: 10.1177/1120700020964988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] [Imported: 08/29/2023]
Abstract
BACKGROUND The number of femoral neck fractures (FNFs) worldwide will drastically increase in the next few decades, reaching 6.3 million by 2050. In the future, therefore, newly-qualified orthopaedic surgeons will treat this kind of injury more frequently than in past decades. This prospective observational study aims to assess whether hip hemiarthroplasty with modular neck, performed via the Hardinge approach, can be safely carried out by orthopaedic residents. METHODS Patients referred to our Level I trauma centre, between January 2016 and June 2017, with displaced intra-articular femoral fractures, were prospectively recruited. All patients underwent cemented modular bipolar hip hemiarthroplasty (Profemur Z, MicroPort Orthopedics Inc., Arlington, TN, USA) via the Hardinge approach, with the patient positioned in lateral decubitus. The surgical procedures were performed by the same surgical and anesthesiology team, under spinal anaesthesia. All patients underwent clinical and radiographic follow-up up to 24 months. Complications and re-operations were recorded. Clinical evaluation was performed using the Harris Hip Score (HHS), Osteoporosis Quality of Life Questionnaire QUALEFFO-41 and EuroQol-5D (EQ-5D) questionnaire. Anteroposterior pelvis x-rays were performed preoperatively, postoperatively and at 1, 3, 6, 12 and 24 months follow-up. RESULTS 118 patients met the inclusion criteria (male: 50; female: 68; mean age: 74.3 years; range 65-88 years) and were included in the current study. 67 patients out of 118 (56.8%) were managed by senior orthopaedic surgeons (Group A), whereas the remaining 51 patients out of 118 (43.2%) were treated by orthopaedic residents (Group B). Hip hemiarthroplasties performed by senior surgeons showed the prevalent use of straight (short or long) necks, whereas, in surgical procedures performed by residents, there was a significantly higher use of varus/valgus, anteverted or retroverted necks. The overall complication rate was significantly higher in Group-B patients, compared with Group-A patients (p = 0.002). The length of hospital stay and the mean clinical scores at 24 months follow-up showed no significant differences. CONCLUSIONS Hip hemiarthroplasty with modular neck can be safely employed during the learning curve of orthopaedic residents. Great efforts, however, should be made in future to improve residents' training in the management of FNFs.
Collapse
|
Observational Study |
5 |
1 |
24
|
Solarino G, Moretti B. Letter to the Editor on "Eighteen-Year Follow-Up Study of 2 Alternative Bearing Surfaces Used in Total Hip Arthroplasty in the Same Young Patients". J Arthroplasty 2020; 35:1956-1957. [PMID: 32279945 DOI: 10.1016/j.arth.2020.03.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 03/11/2020] [Indexed: 02/01/2023] [Imported: 04/23/2025] Open
|
Letter |
5 |
1 |
25
|
Solarino G, Maccagnano G, Saracino M, Moretti B. An Unusual Complication after Infected Total Knee Arthroplasty. JOINTS 2018; 6:241-245. [PMID: 31879721 PMCID: PMC6930123 DOI: 10.1055/s-0039-1697614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Accepted: 08/07/2019] [Indexed: 11/16/2022] [Imported: 04/23/2025]
Abstract
One-stage or two-stage revision total knee arthroplasty (TKA) in periprosthetic joint infections has been at the center of scientific debate for many years. As regards two-stage revision TKA, cement spacers have a good infection control rate with successful results reportable up to 96%, though some studies describe related spacer complications such as stiffness and loss of bone stock. We report a case of a fracture close to the antibiotic-loaded cement spacer in a 74-year-old female patient. Due to the blood tests and high risk of infection, we performed a hybrid external fixator. Six months after the surgery, X-rays did not show signs of fracture consolidation and nonunion was considered as an impending complication; therefore, the decision was made to perform tumor-like total knee arthroplasty. The postoperative evolution was satisfactory and return to daily activity without pain. At the 5-year follow-up, the patient showed a good score of 36-Item Short Form Health Survey and a range of motion from 0 to 90° without pain. The X-rays did not show signs of mobilization, dislocation, recurrence of infection, or other complications.
Collapse
|
Case Reports |
7 |
1 |