Cui L, McWalter EJ, Moran G, Venugopal N. Design and development of a novel flexible ultra-short echo time (FUSE) sequence. Magn Reson Med 2023; 90:1905-1918. [PMID: 37392415 DOI: 10.1002/mrm.29784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 05/28/2023] [Accepted: 06/13/2023] [Indexed: 07/03/2023]
Abstract
PURPOSE To present the validation of a new Flexible Ultra-Short Echo time (FUSE) pulse sequence using a short-T2 phantom. METHODS FUSE was developed to include a range of RF excitation pulses, trajectories, dimensionalities, and long-T2 suppression techniques, enabling real-time interchangeability of acquisition parameters. Additionally, we developed an improved 3D deblurring algorithm to correct for off-resonance artifacts. Several experiments were conducted to validate the efficacy of FUSE, by comparing different approaches for off-resonance artifact correction, variations in RF pulse and trajectory combinations, and long-T2 suppression techniques. All scans were performed on a 3 T system using an in-house short-T2 phantom. The evaluation of results included qualitative comparisons and quantitative assessments of the SNR and contrast-to-noise ratio. RESULTS Using the capabilities of FUSE, we demonstrated that we could combine a shorter readout duration with our improved deblurring algorithm to effectively reduce off-resonance artifacts. Among the different RF and trajectory combinations, the spiral trajectory with the regular half-inc pulse achieves the highest SNRs. The dual-echo subtraction technique delivers better short-T2 contrast and superior suppression of water and agar signals, whereas the off-resonance saturation method successfully suppresses water and lipid signals simultaneously. CONCLUSION In this work, we have validated the use of our new FUSE sequence using a short T2 phantom, demonstrating that multiple UTE acquisitions can be achieved within a single sequence. This new sequence may be useful for acquiring improved UTE images and the development of UTE imaging protocols.
Collapse
|
2
|
Li N, Tous C, Dimov IP, Fei P, Zhang Q, Lessard S, Moran G, Jin N, Kadoury S, Tang A, Martel S, Soulez G. Design of a Patient-Specific Respiratory-Motion-Simulating Platform for In Vitro 4D Flow MRI. Ann Biomed Eng 2022; 51:1028-1039. [PMID: 36580223 DOI: 10.1007/s10439-022-03117-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 12/04/2022] [Indexed: 12/30/2022]
Abstract
Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a leading-edge imaging technique and has numerous medicinal applications. In vitro 4D flow MRI can offer some advantages over in vivo ones, especially in accurately controlling flow rate (gold standard), removing patient and user-specific variations, and minimizing animal testing. Here, a complete testing method and a respiratory-motion-simulating platform are proposed for in vitro validation of 4D flow MRI. A silicon phantom based on the hepatic arteries of a living pig is made. Under the free-breathing, a human volunteer's liver motion (inferior-superior direction) is tracked using a pencil-beam MRI navigator and is extracted and converted into velocity-distance pairs to program the respiratory-motion-simulating platform. With the magnitude displacement of about 1.3 cm, the difference between the motions obtained from the volunteer and our platform is ≤ 1 mm which is within the positioning error of the MRI navigator. The influence of the platform on the MRI signal-to-noise ratio can be eliminated even if the actuator is placed in the MRI room. The 4D flow measurement errors are respectively 0.4% (stationary phantom), 9.4% (gating window = 3 mm), 27.3% (gating window = 4 mm) and 33.1% (gating window = 7 mm). The vessel resolutions decreased with the increase of the gating window. The low-cost simulation system, assembled from commercially available components, is easy to be duplicated.
Collapse
|
3
|
Ellul P, Schembri J, Baldacchino VA, Molnar T, Resal T, Allocca MA, Furfaro F, Dal Buono, Theodoropoulou A, Fragaki M, Tsoukali E, Mantzaris GJ, Phillips F, Radford S, Moran G, Gonzalez HA, Sebastian S, Fousekis F, Christodoulou D, Snir Y, Lerner Z, Yanai H, Michalopoulos G, Tua J, Camilleri L, Papamichael K, Karmiris K, Katsanos K. Post-inflammatory polyps burden as a prognostic marker of disease-outcome in patients with inflammatory bowel disease. J Crohns Colitis 2022; 17:489-496. [PMID: 36322687 DOI: 10.1093/ecco-jcc/jjac169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Indexed: 02/08/2023]
Abstract
INTRODUCTION AND AIM Post-inflammatory polyps (PIPs) are considered as indicators of previous episodes of severe inflammation and mucosal ulceration. Inflammatory bowel disease (IBD), namely Crohn's disease (CD) and ulcerative colitis (UC), exhibit a perpetuating, relapsing, and remitting pattern and PIPs is a frequent sequela of chronicity. The aim of this study was to determine whether a high PIPs burden is associated with a more severe disease course in patients with IBD. METHODS This was a multinational, multicentre, retrospective study. IBD patients previously diagnosed with PIPs were retrieved from the endoscopic database of each centre. PIPs burden was evaluated and associated with demographic and clinical data as well as factors indicating a more unfavorable disease course. RESULTS A total of 504 IBD patients with PIPs were recruited (male: 61.9%). The mean age at IBD diagnosis was 36.9 (±16.8) years. Most patients (74.8%) were diagnosed with UC. A high PIPs burden was present in 53.4% of patients. On multivariable Cox regression analysis, high PIPs burden was independently associated with treatment escalation (HR 1.35, 95% CI 1.04-1.75; P=0.024), hospitalization (HR 1.90; 95% CI 1.24 - 2.90; P=0.003), need for surgery (HR 2.28; 95% CI 1.17-4.44, P=0.02) and younger age at diagnosis (HR 0.99, 95% CI 0.98-0,99; p=0.003). CONCLUSION PIPs burden was associated with a more severe outcome. Future prospective studies should focus on the characterisation of PIPs burden as to further risk stratify this patient cohort.
Collapse
|
4
|
Dimov IP, Tous C, Li N, Barat M, Bomberna T, Debbaut C, Jin N, Moran G, Tang A, Soulez G. Assessment of hepatic arterial hemodynamics with 4D flow MRI: in vitro analysis of motion and spatial resolution related error and in vivo feasibility study in 20 volunteers. Eur Radiol 2022; 32:8639-8648. [PMID: 35731288 DOI: 10.1007/s00330-022-08890-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 04/25/2022] [Accepted: 05/17/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To assess the ability of four-dimensional (4D) flow MRI to measure hepatic arterial hemodynamics by determining the effects of spatial resolution and respiratory motion suppression in vitro and its applicability in vivo with comparison to two-dimensional (2D) phase-contrast MRI. METHODS A dynamic hepatic artery phantom and 20 consecutive volunteers were scanned. The accuracies of Cartesian 4D flow sequences with k-space reordering and navigator gating at four spatial resolutions (0.5- to 1-mm isotropic) and navigator acceptance windows (± 8 to ± 2 mm) and one 2D phase-contrast sequence (0.5-mm in -plane) were assessed in vitro at 3 T. Two sequences centered on gastroduodenal and hepatic artery branches were assessed in vivo for intra - and interobserver agreement and compared to 2D phase-contrast. RESULTS In vitro, higher spatial resolution led to a greater decrease in error than narrower navigator window (30.5 to -4.67% vs -6.64 to -4.67% for flow). In vivo, hepatic and gastroduodenal arteries were more often visualized with the higher resolution sequence (90 vs 71%). Despite similar interobserver agreement (κ = 0.660 and 0.704), the higher resolution sequence had lower variability for area (CV = 20.04 vs 30.67%), flow (CV = 34.92 vs 51.99%), and average velocity (CV = 26.47 vs 44.76%). 4D flow had lower differences between inflow and outflow at the hepatic artery bifurcation (11.03 ± 5.05% and 15.69 ± 6.14%) than 2D phase-contrast (28.77 ± 21.01%). CONCLUSION High-resolution 4D flow can assess hepatic artery anatomy and hemodynamics with improved accuracy, greater vessel visibility, better interobserver reliability, and internal consistency. KEY POINTS • Motion-suppressed Cartesian four-dimensional (4D) flow MRI with higher spatial resolution provides more accurate measurements even when accepted respiratory motion exceeds voxel size. • 4D flow MRI with higher spatial resolution provides substantial interobserver agreement for visualization of hepatic artery branches. • Lower peak and average velocities and a trend toward better internal consistency were observed with 4D flow MRI as compared to 2D phase-contrast.
Collapse
|
5
|
Dassanayake P, Cui L, Finger E, Kewin M, Hadaway J, Soddu A, Jakoby B, Zuehlsdorf S, Lawrence KSS, Moran G, Anazodo UC. caliPER: A software for blood-free parametric Patlak mapping using PET/MRI input function. Neuroimage 2022; 256:119261. [PMID: 35500806 DOI: 10.1016/j.neuroimage.2022.119261] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 04/05/2022] [Accepted: 04/26/2022] [Indexed: 01/23/2023] Open
Abstract
Routine clinical use of absolute PET quantification techniques is limited by the need for serial arterial blood sampling for input function and more importantly by the lack of automated pharmacokinetic analysis tools that can be readily implemented in clinic with minimal effort. PET/MRI provides the ability for absolute quantification of PET probes without the need for serial arterial blood sampling using image-derived input functions (IDIFs). Here we introduce caliPER, a modular and scalable software for simplified pharmacokinetic modelling of PET probes with irreversible uptake or binding based on PET/MR IDIFs and Patlak Plot analysis. caliPER generates regional values or parametric maps of net influx rate (Ki) using reconstructed dynamic PET images and anatomical MRI aligned to PET for IDIF vessel delineation. We evaluated the performance of caliPER for blood-free region-based and pixel-wise Patlak analyses of [18F] FDG by comparing caliPER IDIF to serial arterial blood input functions and its application in imaging brain glucose hypometabolism in Frontotemporal dementia. IDIFs corrected for partial volume errors including spill-out and spill-in effects were similar to arterial blood input functions with a general bias of around 6-8%, even for arteries <5 mm. The Ki and cerebral metabolic rate of glucose estimated using caliPER IDIF were similar to estimates using arterial blood sampling (<2%) and within limits of whole brain values reported in literature. Overall, caliPER is a promising tool for irreversible PET tracer quantification and can simplify the ability to perform parametric analysis in clinical settings without the need for blood sampling.
Collapse
|
6
|
Tous C, Li N, Dimov IP, Kadoury S, Tang A, Häfeli UO, Nosrati Z, Saatchi K, Moran G, Couch MJ, Martel S, Lessard S, Soulez G. Navigation of Microrobots by MRI: Impact of Gravitational, Friction and Thrust Forces on Steering Success. Ann Biomed Eng 2021; 49:3724-3736. [PMID: 34622313 DOI: 10.1007/s10439-021-02865-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 09/07/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Magnetic resonance navigation (MRN) uses MRI gradients to steer magnetic drug-eluting beads (MDEBs) across vascular bifurcations. We aim to experimentally verify our theoretical forces balance model (gravitational, thrust, friction, buoyant and gradient steering forces) to improve the MRN targeted success rate. METHOD A single-bifurcation phantom (3 mm inner diameter) made of poly-vinyl alcohol was connected to a cardiac pump at 0.8 mL/s, 60 beats/minutes with a glycerol solution to reproduce the viscosity of blood. MDEB aggregates (25 ± 6 particles, 200 [Formula: see text]) were released into the main branch through a 5F catheter. The phantom was tilted horizontally from - 10° to +25° to evaluate the MRN performance. RESULTS The gravitational force was equivalent to 71.85 mT/m in a 3T MRI. The gradient duration and amplitude had a power relationship (amplitude=78.717 [Formula: see text]). It was possible, in 15° elevated vascular branches, to steer 87% of injected aggregates if two MRI gradients are simultaneously activated ([Formula: see text] = +26.5 mT/m, [Formula: see text]= +18 mT/m for 57% duty cycle), the flow velocity was minimized to 8 cm/s and a residual pulsatile flow to minimize the force of friction. CONCLUSION Our experimental model can determine the maximum elevation angle MRN can perform in a single-bifurcation phantom simulating in vivo conditions.
Collapse
|
7
|
Poirier SE, Kwan BYM, Jurkiewicz MT, Samargandy L, Iacobelli M, Steven DA, Lam Shin Cheung V, Moran G, Prato FS, Thompson RT, Burneo JG, Anazodo UC, Thiessen JD. An evaluation of the diagnostic equivalence of 18F-FDG-PET between hybrid PET/MRI and PET/CT in drug-resistant epilepsy: A pilot study. Epilepsy Res 2021; 172:106583. [PMID: 33636504 DOI: 10.1016/j.eplepsyres.2021.106583] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 01/27/2021] [Accepted: 02/09/2021] [Indexed: 01/19/2023]
Abstract
OBJECTIVE Hybrid PET/MRI may improve detection of seizure-onset zone (SOZ) in drug-resistant epilepsy (DRE), however, concerns over PET bias from MRI-based attenuation correction (MRAC) have limited clinical adoption of PET/MRI. This study evaluated the diagnostic equivalency and potential clinical value of PET/MRI against PET/CT in DRE. MATERIALS AND METHODS MRI, FDG-PET and CT images (n = 18) were acquired using a hybrid PET/MRI and a CT scanner. To assess diagnostic equivalency, PET was reconstructed using MRAC (RESOLUTE) and CT-based attenuation correction (CTAC) to generate PET/MRI and PET/CT images, respectively. PET/MRI and PET/CT images were compared qualitatively through visual assessment and quantitatively through regional standardized uptake value (SUV) and z-score assessment. Diagnostic accuracy and sensitivity of PET/MRI and PET/CT for SOZ detection were calculated through comparison to reference standards (clinical hypothesis and histopathology, respectively). RESULTS Inter-reader agreement in visual assessment of PET/MRI and PET/CT images was 78 % and 81 %, respectively. PET/MRI and PET/CT were strongly correlated in mean SUV (r = 0.99, p < 0.001) and z-scores (r = 0.92, p < 0.001) across all brain regions. MRAC SUV bias was <5% in most brain regions except the inferior temporal gyrus, temporal pole, and cerebellum. Diagnostic accuracy and sensitivity were similar between PET/MRI and PET/CT (87 % vs. 85 % and 83 % vs. 83 %, respectively). CONCLUSION We demonstrate here that PET/MRI with optimal MRAC can yield similar diagnostic performance as PET/CT. Nevertheless, further exploration of the potential added value of PET/MRI is necessary before clinical adoption of PET/MRI for epilepsy imaging.
Collapse
|
8
|
Li N, Jiang Y, Plantefève R, Michaud F, Nosrati Z, Tremblay C, Saatchi K, Häfeli UO, Kadoury S, Moran G, Joly F, Martel S, Soulez G. Magnetic Resonance Navigation for Targeted Embolization in a Two-Level Bifurcation Phantom. Ann Biomed Eng 2019; 47:2402-2415. [PMID: 31290038 DOI: 10.1007/s10439-019-02317-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Accepted: 06/28/2019] [Indexed: 12/22/2022]
Abstract
This work combines a particle injection system with our proposed magnetic resonance navigation (MRN) sequence with the intention of validating MRN in a two-bifurcation phantom for endovascular treatment of hepatocellular carcinoma (HCC). A theoretical physical model used to calculate the most appropriate size of the magnetic drug-eluting bead (MDEB, 200 μm) aggregates was proposed. The aggregates were injected into the phantom by a dedicated particle injector while a trigger signal was automatically sent to the MRI to start MRN which consists of interleaved tracking and steering sequences. When the main branch of the phantom was parallel to B0, the aggregate distribution ratio in the (left-left, left-right, right-left and right-right divisions was obtained with results of 8, 68, 24 and 0% respectively at baseline (no MRN) and increased to 84%, 100, 84 and 92% (p < 0.001, p = 0.004, p < 0.001, p < 0.001) after implementing our MRN protocol. When the main branch was perpendicular to B0, the right-left branch, having the smallest baseline distribution rate of 0%, reached 80% (p < 0.001) after applying MRN. Moreover, the success rate of MRN was always more than 92% at the 1st bifurcation in the experiments above.
Collapse
|
9
|
Michaud F, Li N, Plantefève R, Nosrati Z, Tremblay C, Saatchi K, Moran G, Bigot A, Häfeli UO, Kadoury S, Tang A, Perreault P, Martel S, Soulez G. Selective embolization with magnetized microbeads using magnetic resonance navigation in a controlled-flow liver model. Med Phys 2018; 46:789-799. [PMID: 30451303 DOI: 10.1002/mp.13298] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/18/2018] [Accepted: 11/04/2018] [Indexed: 12/29/2022] Open
Abstract
PURPOSE The purpose of this study was to demonstrate the feasibility of using a custom gradient sequence on an unmodified 3T magnetic resonance imaging (MRI) scanner to perform magnetic resonance navigation (MRN) by investigating the blood flow control method in vivo, reproducing the obtained rheology in a phantom mimicking porcine hepatic arterial anatomy, injecting magnetized microbead aggregates through an implantable catheter, and steering the aggregates across arterial bifurcations for selective tumor embolization. MATERIALS AND METHODS In the first phase, arterial hepatic velocity was measured using cine phase-contrast imaging in seven pigs under free-flow conditions and controlled-flow conditions, whereby a balloon catheter is used to occlude arterial flow and saline is injected at different rates. Three of the seven pigs previously underwent selective lobe embolization to simulate a chemoembolization procedure. In the second phase, the measured in vivo controlled-flow velocities were approximately reproduced in a Y-shaped vascular bifurcation phantom by injecting saline at an average rate of 0.6 mL/s with a pulsatile component. Aggregates of 200-μm magnetized particles were steered toward the right or left hepatic branch using a 20-mT/m MRN gradient. The phantom was oriented at 0°, 45°, and 90° with respect to the B0 magnetic field. The steering differences between left-right gradient and baseline were calculated using Fisher's exact test. A theoretical model of the trajectory of the aggregate within the main phantom branch taking into account gravity, magnetic force, and hydrodynamic drag was also designed, solved, and validated against the experimental results to characterize the physical limitations of the method. RESULTS At an injection rate of 0.5 mL/s, the average flow velocity decreased from 20 ± 15 to 8.4 ± 5.0 cm/s after occlusion in nonembolized pigs and from 13.6 ± 2.0 to 5.4 ± 3.0 cm/s in previously embolized pigs. The pulsatility index measured to be 1.7 ± 1.8 and 1.1 ± 0.1 for nonembolized and embolized pigs, respectively, decreased to 0.6 ± 0.4 and 0.7 ± 0.3 after occlusion. For MRN performed at each orientation, the left-right distribution of aggregates was 55%, 25%, and 75% on baseline and 100%, 100%, and 100% (P < 0.001, P = 0.003, P = 0.003) after the application of MRN, respectively. According to the theoretical model, the aggregate reaches a stable transverse position located toward the direction of the gradient at a distance equal to 5.8% of the radius away from the centerline within 0.11 s, at which point the aggregate will have transited through a longitudinal distance of 1.0 mm from its release position. CONCLUSION In this study, we showed that the use of a balloon catheter reduces arterial hepatic flow magnitude and variation with the aim to reduce steering failures caused by fast blood flow rates and low magnetic steering forces. A mathematical model confirmed that the reduced flow rate is low enough to maximize steering ratio. After reproducing the flow rate in a vascular bifurcation phantom, we demonstrated the feasibility of MRN after injection of microparticle aggregates through a dedicated injector. This work is an important step leading to MRN-based selective embolization techniques in humans.
Collapse
|
10
|
Asafu-Adjei D, Moran G, Li G, Lipsky M, Stember D, Stahl P. 335 Implant Selection Patterns and Reoperation Rates amongst Solid Organ Transplant Recipients that Underwent Penile Prosthesis Surgery. J Sex Med 2018. [DOI: 10.1016/j.jsxm.2017.11.215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Olave C, Morales N, Uberti B, Henriquez C, Sarmiento J, Ortloff A, Folch H, Moran G. Tamoxifen induces apoptotic neutrophil efferocytosis in horses. Vet Res Commun 2018; 42:57-63. [PMID: 29297134 DOI: 10.1007/s11259-017-9709-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 12/26/2017] [Indexed: 02/08/2023]
Abstract
Macrophages and neutrophils are important cellular components in the process of acute inflammation and its subsequent resolution, and evidence increasingly suggests that they play important functions during the resolution of chronic, adaptive inflammatory processes. Exacerbated neutrophil activity can be harmful to surrounding tissues; this is important in a range of diseases, including allergic asthma and chronic obstructive pulmonary disease in humans, and equine asthma (also known as recurrent airway obstruction (RAO). Tamoxifen (TX) is a non-steroidal estrogen receptor modulator with effects on cell growth and survival. Previous studies showed that TX treatment in horses with induced acute pulmonary inflammation promoted early apoptosis of blood and BALF neutrophils, reduction of BALF neutrophils, and improvement in animals' clinical status. The aim of this study was to describe if TX induces in vitro efferocytosis of neutrophils by alveolar macrophages. Efferocytosis assay, myeloperoxidase (MPO) detection and translocation phosphatidylserine (PS) were performed on neutrophils isolated from peripheral blood samples from five healthy horses. In in vitro samples from heathy horses, TX treatment increases the phenomenon of efferocytosis of peripheral neutrophils by alveolar macrophages. Similar increases in supernatant MPO concentration and PS translocation were observed in TX-treated neutrophils, compared to control cells. In conclusion, these results confirm that tamoxifen has a direct effect on equine peripheral blood neutrophils, through stimulation of the engulfment of apoptotic neutrophils by alveolar macrophages.
Collapse
|
12
|
Borlone C, Morales N, Henriquez C, Folch H, Olave C, Sarmiento J, Uberti B, Moran G. In Vitro effects of tamoxifen on equine neutrophils. Res Vet Sci 2016; 110:60-64. [PMID: 28159238 DOI: 10.1016/j.rvsc.2016.11.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Revised: 10/26/2016] [Accepted: 11/03/2016] [Indexed: 10/20/2022]
Abstract
Neutrophils participate in innate immunity as the first line of host defense against microorganisms. However, exacerbated neutrophil activity can be harmful to surrounding tissues; this is important in a range of diseases, including allergic asthma and chronic obstructive pulmonary disease in humans, and equine asthma (also known as recurrent airway obstruction (RAO). Tamoxifen (TX) is a non-steroidal estrogen receptor modulator with effects on cell growth and survival. Previous preliminary studies showed that TX treatment in horses with induced acute pulmonary inflammation promoted early apoptosis of blood and BALF neutrophils, reduction of BALF neutrophils, and improvement in animals' clinical status. The aim of this study was to evaluate the in vitro effect of TX on functional tests in equine peripheral blood neutrophils. Chemotaxis, respiratory burst production and phagocytosis assays were performed on neutrophils isolated from peripheral blood samples from 10 healthy horses. Results showed that IL-8 stimulated cells decrease their chemotactic index when treated with TX (1 and 10μM). Respiratory burst production was also dampened after treatment with TX. In conclusion, these results confirm that tamoxifen has a direct action on equine peripheral blood neutrophils. However, more in vivo and in vitro studies are required to fully understand the mechanisms of action of TX on neutrophils, in order to elucidate if it can be used as treatment in disorders such as allergic asthma in humans and horses.
Collapse
|
13
|
Miao S, Wang ZJ, Pan L, Butler J, Moran G, Liao R. Scatter to volume registration for model-free respiratory motion estimation from dynamic MRIs. Comput Med Imaging Graph 2016; 52:72-81. [PMID: 27180910 DOI: 10.1016/j.compmedimag.2016.03.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 03/09/2016] [Accepted: 03/10/2016] [Indexed: 10/22/2022]
Abstract
Respiratory motion is one major complicating factor in many image acquisition applications and image-guided interventions. Existing respiratory motion estimation and compensation methods typically rely on breathing motion models learned from certain training data, and therefore may not be able to effectively handle intra-subject and/or inter-subject variations of respiratory motion. In this paper, we propose a respiratory motion compensation framework that directly recovers motion fields from sparsely spaced and efficiently acquired dynamic 2-D MRIs without using a learned respiratory motion model. We present a scatter-to-volume deformable registration algorithm to register dynamic 2-D MRIs with a static 3-D MRI to recover dense deformation fields. Practical considerations and approximations are provided to solve the scatter-to-volume registration problem efficiently. The performance of the proposed method was investigated on both synthetic and real MRI datasets, and the results showed significant improvements over the state-of-art respiratory motion modeling methods. We also demonstrated a potential application of the proposed method on MRI-based motion corrected PET imaging using hybrid PET/MRI.
Collapse
|
14
|
Daly P, Moran G. Safety assessment of a novel active ingredient, acetyl aspartic acid, according to the EU Cosmetics Regulation and the Scientific Committee on Consumer Safety guidelines. Int J Cosmet Sci 2015; 37 Suppl 1:21-7. [PMID: 26114401 DOI: 10.1111/ics.12257] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Accepted: 06/17/2015] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Acetyl aspartic acid (A-A-A) was proposed as a new novel active ingredient for use in cosmetics. The safety of A-A-A was assessed by following an in-house-developed 'New Ingredient Testing Strategy', which was designed in accordance with the Scientific Committee on Consumer Safety (SCCS) notes of guidance and the requirements of Annex I of the EU Cosmetics Regulation. The aim of the project was to determine whether A-A-A was safe for use in cosmetics and to determine a maximum permitted safe level in the formulations. METHODS A literature review was conducted, consulting over 40 different information sources. This highlighted a number of gaps which required testing data. A-A-A was tested for phototoxicity according to OECD test guideline 432, skin irritation according to OECD test guideline 439 and eye irritation according to OECD test guideline 437. Dermal absorption of A-A-A was measured according to OECD test guideline 428 and was used to calculate the margin of safety (MoS). Finally, A-A-A was tested in a human repeat insult patch test (HRIPT) and a 14-day in-use tolerance study. RESULTS A-A-A was non-phototoxic and was non-irritating to skin and eyes in in vitro testing. Dermal absorption was calculated to be 5%. The MoS for A-A-A was 351, at a level of 5%, for all cosmetic product types, indicating no systemic safety toxicity concern. A-A-A at 5% under occlusive patch on a panel of 50 adult volunteers induced no skin irritation or allergic reaction in the HRIPT study. Finally, repeated application of A-A-A to the periocular area, twice per day for 14 days, in 21 female volunteers, demonstrated that 1% A-A-A was well tolerated following dermatological and ophthalmological assessment in a cosmetic formulation. CONCLUSION A-A-A was assessed as safe by the cosmetic safety assessor for use in cosmetics at a level of 5% in all cosmetic product types, in line with the requirements of the EU Cosmetics Regulation and in accordance with the SCCS notes of guidance.
Collapse
|
15
|
Gentile CL, Weir TL, Cox-York KA, Wei Y, Wang D, Reese L, Moran G, Estrada A, Mulligan C, Pagliassotti MJ, Foster MT. The role of visceral and subcutaneous adipose tissue fatty acid composition in liver pathophysiology associated with NAFLD. Adipocyte 2015; 4:101-12. [PMID: 26167414 DOI: 10.4161/21623945.2014.978662] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Revised: 10/10/2014] [Accepted: 10/15/2014] [Indexed: 11/19/2022] Open
Abstract
Visceral adiposity is associated with type-2-diabetes, inflammation, dyslipidemia and non-alcoholic fatty liver disease (NAFLD), whereas subcutaneous adiposity is not. We hypothesized that the link between visceral adiposity and liver pathophysiology involves inherent or diet-derived differences between visceral and subcutaneous adipose tissue to store and mobilize saturated fatty acids. The goal of the present study was to characterize the fatty acid composition of adipose tissue triglyceride and portal vein fatty acids in relation to indices of liver dysregulation. For 8 weeks rats had free access to control (CON; 12.9% corn/safflower oil; 3.6 Kcal/g), high saturated fat (SAT; 45.2% cocoa butter; 4.5 Kcal/g) or high polyunsaturated fat (PUFA; 45.2% safflower oil; 4.5 Kcal/g) diets. Outcome measures included glucose tolerance, visceral and subcutaneous adipose tissue triglyceride, liver phospholipids and plasma (portal and systemic) free fatty acid composition, indices of inflammation and endoplasmic reticulum stress in the liver and adipose tissue depots and circulating adipo/cytokines. Hepatic triglycerides were significantly increased in both high fat diet groups compared to control and were significantly higher in PUFA compared to SAT. Although glucose tolerance was not different among diet groups, SAT increased markers of inflammation and ER stress in the liver and both adipose tissue depots. Fatty acid composition did not differ among adipose depots or portal blood in any dietary group. Overall, these data suggest that diets enriched in saturated fatty acids are associated with liver inflammation, ER stress and injury, but that any link between visceral adipose tissue and these liver indices does not involve selective changes to fatty acid composition in this depot or the portal vein.
Collapse
|
16
|
Moran G, Wei Y, Wang D, Pagliassotti M. The role of mitofusin 2 in saturated fatty acid induced ER stress in H4IIE liver cells (1116.4). FASEB J 2014. [DOI: 10.1096/fasebj.28.1_supplement.1116.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Terp S, Krishnadasan A, Bowen W, Joo J, Furoy D, Chan J, Moran G, Talan D. Introduction of Rapid Methicillin-Resistant Staphylococcus aureus Polymerase Chain Reaction Testing and Antibiotic Selection Among Hospitalized Patients With Purulent Skin Infections. Clin Infect Dis 2014; 58:e129-32. [DOI: 10.1093/cid/ciu039] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
|
18
|
Moran G, Folch H, Henriquez C, Ortloff A, Barria M. Reaginic antibodies from horses with Recurrent Airway Obstruction produce mast cell stimulation. Vet Res Commun 2012; 36:251-8. [DOI: 10.1007/s11259-012-9534-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/01/2012] [Indexed: 11/28/2022]
|
19
|
Bisceglia R, Jenkins JM, Wigg KG, O’Connor TG, Moran G, Barr CL. Arginine vasopressin 1a receptor gene and maternal behavior: evidence of association and moderation. GENES BRAIN AND BEHAVIOR 2012; 11:262-8. [DOI: 10.1111/j.1601-183x.2012.00769.x] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
20
|
Moran G. "Near famine": the Roman Catholic Church and the subsistence crisis of 1879-82. STUDIA HIBERNICA 2010; 32:155-177. [PMID: 20191701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
21
|
Merinville E, Laloeuf A, Moran G, Jalby O, Rawlings AV. Exfoliation for sensitive skin with neutralized salicylic acid? Int J Cosmet Sci 2009. [DOI: 10.1111/j.1468-2494.2009.00501_2.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
22
|
Scott T, Swan H, Moran G, Mondal T, Jones J, Guram K, Huff J. Increasing the Detection Rate of Normal Fetal Cardiac Structures: A Real-Time Approach. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY 2008. [DOI: 10.1177/8756479308315234] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The purpose of this study was to determine if acquiring real-time sweeps of the fetal heart would be a more effective method of identifying normal cardiac structures compared with using static images during routine second-trimester obstetric sonograms. Subjects were scanned using three different techniques. The static image acquisition (protocol A) included three images of the fetal heart. Protocol B used two gray-scale sweeps through the fetal heart. Protocol C acquired three color loops of the fetal heart. The sweeps demonstrated a complete normal cardiac assessment in 71% of studies, compared with the static image and color Doppler techniques that completed a normal cardiac assessment in only 39% of studies, respectively. The real-time technique detected four chambers, the left ventricular outflow tract (LVOT), the right ventricular outflow tract (RVOT), the LVOT/RVOT crossover, and size and axis of the heart with a greater frequency than the static images and color loops in all cases. In addition, the real-time technique was able to demonstrate the pulmonary veins in 56% of cases compared with 3.6% for static images. The color Doppler acquisition demonstrated blood flow through the atrial-ventricular and semilunar valves in 86% of cases.
Collapse
|
23
|
Forbes LM, Evans EM, Moran G, Pederson DR. Change in Atypical Maternal Behavior Predicts Change in Attachment Disorganization From 12 to 24 Months in a High-Risk Sample. Child Dev 2007; 78:955-71. [PMID: 17517015 DOI: 10.1111/j.1467-8624.2007.01043.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This longitudinal study examined links between disorganization and atypical maternal behavior at 12 and 24 months in 71 adolescent mother-child dyads. Organized attachment and maternal not disrupted behavior were more stable than disorganization and disrupted behavior, respectively. At both ages, disorganization and maternal disrupted behavior were significantly correlated. Change in atypical maternal behavior predicted change in disorganization across time. The results provide substantial support for extant theories linking anomalous maternal behavior to the development of disorganized attachment. The Interesting-but-Scary paradigm, introduced in this study, promises to be a useful tool for assessing attachment and maternal behavior in toddlerhood.
Collapse
|
24
|
Mothersill C, Moran G, McNeill F, Gow MD, Denbeigh J, Prestwich W, Seymour CB. A role for bioelectric effects in the induction of bystander signals by ionizing radiation? Dose Response 2007; 5:214-29. [PMID: 18648606 DOI: 10.2203/dose-response.06-011.mothersill] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
The induction of "bystander effects" i.e. effects in cells which have not received an ionizing radiation track, is now accepted but the mechanisms are not completely clear. Bystander effects following high and low LET radiation exposure are accepted but mechanisms are still not understood. There is some evidence for a physical component to the signal. This paper tests the hypothesis that bioelectric or biomagnetic phenomena are involved. Human immortalized skin keratinocytes and primary explants of mouse bladder and fish skin, were exposed directly to ionizing radiation or treated in a variety of bystander protocols. Exposure of cells was conducted by shielding one group of flasks using lead, to reduce the dose below the threshold of 2mGy (60)Cobalt gamma rays established for the bystander effect. The endpoint for the bystander effect in the reporter system used was reduction in cloning efficiency (RCE). The magnitude of the RCE was similar in shielded and unshielded flasks. When cells were placed in a Faraday cage the magnitude of the RCE was less but not eliminated. The results suggest that liquid media or cell-cell contact transmission of bystander factors may be only part of the bystander mechanism. Bioelectric or bio magnetic fields may have a role to play. To test this further, cells were placed in a Magnetic Resonance Imaging (MRI) machine for 10 min using a typical head scan protocol. This treatment also induced a bystander response. Apart from the obvious clinical relevance, the MRI results further suggest that bystander effects may be produced by non-ionizing exposures. It is concluded that bioelectric or magnetic effects may be involved in producing bystander signaling cascades commonly seen following ionizing radiation exposure.
Collapse
|
25
|
Borompichaichartkul C, Moran G, Srzednicki G, Price W. Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) studies of corn at subzero temperatures. J FOOD ENG 2005. [DOI: 10.1016/j.jfoodeng.2004.07.018] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|