1
|
Hirani D, Thielen F, Vohlen C, Danopoulos S, Mansouri S, Haznedar-Karakaya P, Mohr J, Wilke R, Koningsbruggen-Rietschel S, Al-Alam D, Savai R, Dötsch J, Alejandre Alcazar MA. CXCL10 deficiency protects from lung macrophage invasion and enables
lung growth during acute injury and recovery in experimental bronchopulmonary
dysplasia. KLINISCHE PADIATRIE 2022. [DOI: 10.1055/s-0042-1754519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
2
|
Last A, Gutekunst J, Opolka A, Krug M, Schwitzke C, Koch R, Mohr J. Liquid compound refractive X-ray lens. OPTICS EXPRESS 2020; 28:22144-22150. [PMID: 32752481 DOI: 10.1364/oe.389058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 06/01/2020] [Indexed: 06/11/2023]
Abstract
We introduce the concept of a liquid compound refractive X-ray zoom lens. The lens is generated by pumping a suitable liquid lens material like water, alcohol or heated lithium through a line of nozzles each forming a jet with the cross section of lens elements. The system is housed, so there is a liquid-circulation. This lens can be used in white beam at high brilliance synchrotron sources, as radiation damages are cured by the continuous reformation of the lens. The focal length can be varied by closing nozzles, thus reducing the number of lens elements in the beam.
Collapse
|
3
|
Lübben M, Cüppers F, Mohr J, von Witzleben M, Breuer U, Waser R, Neumann C, Valov I. Design of defect-chemical properties and device performance in memristive systems. SCIENCE ADVANCES 2020; 6:eaaz9079. [PMID: 32548248 PMCID: PMC7272230 DOI: 10.1126/sciadv.aaz9079] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 02/24/2020] [Indexed: 05/24/2023]
Abstract
Future development of the modern nanoelectronics and its flagships internet of things, artificial intelligence, and neuromorphic computing is largely associated with memristive elements, offering a spectrum of inevitable functionalities, atomic level scalability, and low-power operation. However, their development is limited by significant variability and still phenomenologically orientated materials' design strategy. Here, we highlight the vital importance of materials' purity, demonstrating that even parts-per-million foreign elements substantially change performance. Appropriate choice of chemistry and amount of doping element selectively enhances the desired functionality. Dopant/impurity-dependent structure and charge/potential distribution in the space-charge layers and cell capacitance determine the device kinetics and functions. The relation between chemical composition/purity and switching/neuromorphic performance is experimentally evidenced, providing directions for a rational design of future memristive devices.
Collapse
|
4
|
Amschler K, Phillip S, Mohr J, Wilsmann-Theis D, Poortinga S, Gerdes S, Mössner R. Long-term follow-up of 22 psoriatic patients treated with ixekizumab after failure of secukinumab. Dermatol Online J 2020; 26:13030/qt11d602x5. [PMID: 32239902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Accepted: 03/26/2020] [Indexed: 06/11/2023] Open
Abstract
The original article was published on February 15, 2020 and corrected on March 26, 2020. The revised version of the article amends the table and figure, while leaving the text largely unchanged. The changes appear in the revised online PDF copy of this article.
Collapse
|
5
|
Amschler K, Phillip S, Mohr J, Wilsmann-Theis D, Poortinga S, Gerdes S, Mössner R. Long-term follow-up of 22 psoriatic patients treated with ixekizumab after failure of secukinumab. Dermatol Online J 2020; 26:13030/qt235408bf. [PMID: 32155021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 03/02/2020] [Indexed: 06/10/2023] Open
Abstract
Switching of biologic agents in treatment of plaque psoriasis is a common strategy. Only a few studies are available on switching between IL17A-blockers. In a retrospective study, we identified 22 psoriasis patients who, after failing secukinumab as a first IL17A-blocker received ixekizumab with an observation period of at least 24 weeks. At last observation 10/22 patients had a good response (PASI75 or PASI<3) using ixekizumab therapy. None of five patients with primary non-response to secukinumab reached a good, durable response to ixekizumab. In conclusion, ixekizumab appears to be a therapeutic option as a second IL17A-blocker in psoriasis patients who did not show a primary non-response to secukinumab.
Collapse
|
6
|
Amschler K, Phillip S, Mohr J, Wilsmann-Theis D, Poortinga S, Gerdes S, Mössner R. Long-term follow-up of 22 psoriatic patients treated with ixekizumab after failure of secukinumab. Dermatol Online J 2020. [DOI: 10.5070/d3262047415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
7
|
Amschler K, Phillip S, Mohr J, Wilsmann-Theis D, Poortinga S, Gerdes S, Mössner R. Long-term follow-up of 22 psoriatic patients treated with ixekizumab after failure of secukinumab. Dermatol Online J 2020. [DOI: 10.5070/d3261047182] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
8
|
Mamyrbayev T, Ikematsu K, Meyer P, Ershov A, Momose A, Mohr J. Super-Resolution Scanning Transmission X-Ray Imaging Using Single Biconcave Parabolic Refractive Lens Array. Sci Rep 2019; 9:14366. [PMID: 31591435 PMCID: PMC6779765 DOI: 10.1038/s41598-019-50869-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 09/11/2019] [Indexed: 11/09/2022] Open
Abstract
A new super resolution imaging technique which potentially enables sub-µm spatial resolution, using a detector of pixels much larger than the spatial resolution, is proposed. The method utilizes sample scanning through a large number of identical X-ray microprobes periodically spaced (the period corresponds to a multiple of the pixel size), which reduces drastically the scanning time. The information about the sample illuminated by the microprobes is stored by large detector pixels. Using these data and sample position information, a super-resolution image reconstruction is performed. With a one-dimensional (1D) high aspect ratio nickel single lens array designed for theoretically expected sub-µm microprobes at 17 keV and fabricated by deep X-ray lithography and electroforming technique, 2 µm X-ray microprobes with a period of 10 µm were achieved. We performed a first experiment at KARA synchrotron facility, and it was demonstrated that the smallest structure of a test pattern with a size of 1.5 µm could be easily resolved by using images generated from a detector having a pixel size of 10.4 µm. This new approach has a great potential for providing a new microscopic imaging modality with a large field of view and short scan time.
Collapse
|
9
|
Kornemann E, Zhou T, Márkus O, Opolka A, Schülli TU, Mohr J, Last A. X-ray zoom lens allows for energy scans in X-ray microscopy. OPTICS EXPRESS 2019; 27:185-195. [PMID: 30645366 DOI: 10.1364/oe.27.000185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 12/10/2018] [Indexed: 06/09/2023]
Abstract
We introduce a new design and development of a compound refractive X-ray zoom lens for energy scans in X-ray microscopy. Energy scans are, in principle, equivalent to radial scans in the reciprocal space for X-ray diffraction. Thanks to the absence of sample or detector motions, energy scans are better suited for microscopy, which requires high stability. In addition, close to the absorption edge of an element, energy scans can yield chemical information when coupled with resonant effects in full field diffraction X-ray microscopy (FFDXM) or X-ray absorption near edge structure (XANES) microscopy. Here, we demonstrate the concept by using a customized compound refractive X-ray zoom lens for 11 keV near the Ge Kα-edge. The working distance and magnification were kept constant during the energy scans by adapting the lens composition on switchable zoom lens fingers. This alleviates the need to reposition the lens while changing the energy and makes quantitative analysis more convenient for FFDXM. The fabricated zoom lens was characterized and proven suitable for the proposed measurement.
Collapse
|
10
|
Márkus O, Greving I, Kornemann E, Storm M, Beckmann F, Mohr J, Last A. Optimizing illumination for full field imaging at high brilliance hard X-ray synchrotron sources. OPTICS EXPRESS 2018; 26:30435-30443. [PMID: 30469917 DOI: 10.1364/oe.26.030435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 10/06/2018] [Indexed: 06/09/2023]
Abstract
A new technique is presented to overcome beam size limitation in full field imaging at high brilliance synchrotron sources using specially designed refractive X-ray optics. These optics defocus the incoming beam in vertical direction and reshape the intensity distribution from a Gaussian to a more desirable top-hat-shaped profile at the same time. With these optics X-ray full-field imaging of extended objects becomes possible without having to stack several scans or applying a cone beam geometry in order to image the entire specimen. For in situ experiments in general and for diffraction limited sources in particular this gain in field of view and the optimization of the intensity distribution is going to be very beneficial.
Collapse
|
11
|
Patschan D, Sugiarto N, Henze E, Mößner R, Mohr J, Müller GA, Patschan S. Early endothelial progenitor cells and vascular stiffness in psoriasis and psoriatic arthritis. Eur J Med Res 2018; 23:56. [PMID: 30413175 PMCID: PMC6225664 DOI: 10.1186/s40001-018-0352-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Accepted: 10/21/2018] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Both psoriasis (Ps) and psoriasis arthritis (PsA) have been associated with increased cardiovascular risk. Also, both are characterized by increased neovascularization. Endothelial progenitor cells (EPCs) have been implicated in promoting vascular repair in ischemic diseases. The aim of the study was to correlate the EPC system with CV risk factors and with parameters of vascular stiffness in Ps and PsA. METHODS Twenty-six healthy subjects, 30 patients with Ps, and 31 patients PsA were included in the study. eEPC regeneration was evaluated by a colony-forming assay, circulating eEPCs were measured by cytometric analysis. For vascular analysis, all subjects underwent quantification of pulse wave velocity (PWV) and augmentation index (AIX). RESULTS Patients were categorized upon the duration of disease, severity of skin involvement (PASI-Ps), individual pain as reflected by the VAS (PsA), CRP values, and history of treatment with one or more biologicals. Regarding the eEPC system, no significant differences were observed between the respective categories. Correlation analyses between parameters of vascular stiffness (PWV and AIX) and patterns of colony formation/circulating eEPCs did not show any correlation at all. CONCLUSION Parameters of vascular stiffness are not significantly deteriorated in Ps/PsA. Thus, pulse wave analysis may not be suitable for CVR assessment in certain autoimmune-mediated diseases. Regenerative activity of the eEPC system/circulating eEPC numbers are not altered in Ps/PsA. One may conclude that malfunctions of the eEPC are not substantially involved in perpetuating the micro-/macrovascular alterations in Ps/PsA.
Collapse
|
12
|
Eschbach D, Horst K, Sassen M, Andruszkow J, Mohr J, Debus F, Vogt N, Steinfeldt T, Hildebrand F, Schöller K, Uhl E, Wulf H, Ruchholtz S, Pape H, Frink M. Hypothermia does not influence liver damage and function in a porcine polytrauma model. Technol Health Care 2018; 26:209-221. [PMID: 28968251 DOI: 10.3233/thc-171043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Previous studies revealed evidence that induced hypothermia attenuates ischemic organ injuries after severe trauma. In the present study, the effect of hypothermia on liver damage was investigated in a porcine long term model of multi-system injury, consisting of blunt chest trauma, penetrating abdominal trauma, musculoskeletal injury, and hemorrhagic shockMETHODS: In 30 pigs, a standardized polytrauma including blunt chest trauma, penetrating abdominal trauma, musculoskeletal injury, and hemorrhagic shock of 45% of total blood volume was induced. Following trauma, hypothermia of 33∘C was induced for 12 h and intensive care treatment was evaluated for 48 h. As outcome parameters, we assessed liver function and serum transaminase levels as well as a histopathological analysis of tissue samples. A further 10 animals served as controls. RESULTS Serum transaminase levels were increased at the end of the observation period following hypothermia without reaching statistical significance compared to normothermic groups. Liver function was preserved (p⩽ 0.05) after the rewarming period in hypothermic animals but showed no difference at the end of the observation period. In H&E staining, cell death was slightly increased hypothermic animals and caspase-3 staining displayed tendency towards more apoptosis in hypothermic group as well. CONCLUSIONS Induction of hypothermia could not significantly improve hepatic damage during the first 48 h following major trauma. Further studies focusing on multi-organ failure including a longer observation period are required to illuminate the impact of hypothermia on hepatic function in multiple trauma patients.
Collapse
|
13
|
Kornemann E, Márkus O, Opolka A, Zhou T, Greving I, Storm M, Krywka C, Last A, Mohr J. Miniaturized compound refractive X-ray zoom lens. OPTICS EXPRESS 2017; 25:22455-22466. [PMID: 29041555 DOI: 10.1364/oe.25.022455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 08/25/2017] [Indexed: 06/07/2023]
Abstract
We introduce the concept of a miniaturized compound refractive X-ray zoom lens consisting of SU-8 lenses fabricated by deep X-ray lithography. The focal length can be varied by changing the number of lens elements placed in the beam. We use suitable actuators to move single lens elements reversibly out of the beam. The X-ray zoom lens can accept different X-ray energies while keeping a fixed working distance, or vary the focal distance for a fixed energy. The latter is useful in tuning the magnification factor in full field microscopy.
Collapse
|
14
|
Horn F, Gelse K, Jabari S, Hauke C, Kaeppler S, Ludwig V, Meyer P, Michel T, Mohr J, Pelzer G, Rieger J, Riess C, Seifert M, Anton G. High-energy x-ray Talbot–Lau radiography of a human knee. ACTA ACUST UNITED AC 2017; 62:6729-6745. [DOI: 10.1088/1361-6560/aa7721] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
15
|
Fingerle A, Willer K, Gromann L, de Marco F, Herzen J, Achterhold K, Gleich B, Münzel D, Scherer K, Renz M, Renger B, Kopp F, Kriner F, Fischer F, Braun C, Auweter S, Hellbach K, Reiser M, Schröter T, Mohr J, Yaroshenko A, Maack H, Pralow T, van der Heijden H, Proksa R, Koehler T, Wieberneit N, Rindt K, Rummeny E, Pfeiffer F, Noël P. Erste Ergebnisse der Dunkelfeld-Radiografie des menschlichen Thorax. ROFO-FORTSCHR RONTG 2017. [DOI: 10.1055/s-0037-1600189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
16
|
Mohr J, Germain M, Winters M, Fraser S, Duong A, Garibaldi A, Simunovic N, Alsop D, Dao D, Bessemer R, Ayeni OR. Disinfection of human musculoskeletal allografts in tissue banking: a systematic review. Cell Tissue Bank 2016; 17:573-584. [PMID: 27665294 PMCID: PMC5116033 DOI: 10.1007/s10561-016-9584-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 09/09/2016] [Indexed: 01/12/2023]
Abstract
Musculoskeletal allografts are typically disinfected using antibiotics, irradiation or chemical methods but protocols vary significantly between tissue banks. It is likely that different disinfection protocols will not have the same level of microorganism kill; they may also have varying effects on the structural integrity of the tissue, which could lead to significant differences in terms of clinical outcome in recipients. Ideally, a disinfection protocol should achieve the greatest bioburden reduction with the lowest possible impact on tissue integrity. A systematic review of three databases found 68 laboratory and clinical studies that analyzed the microbial bioburden or contamination rates of musculoskeletal allografts. The use of peracetic acid–ethanol or ionizing radiation was found to be most effective for disinfection of tissues. The use of irradiation is the most frequently published method for the terminal sterilization of musculoskeletal allografts; it is widely used and its efficacy is well documented in the literature. However, effective disinfection results were still observed using the BioCleanse™ Tissue Sterilization process, pulsatile lavage with antibiotics, ethylene oxide, and chlorhexidine. The variety of effective methods to reduce contamination rate or bioburden, in conjunction with limited high quality evidence provides little support for the recommendation of a single bioburden reduction method.
Collapse
|
17
|
Germain M, Strong DM, Dowling G, Mohr J, Duong A, Garibaldi A, Simunovic N, Ayeni OR. Disinfection of human cardiac valve allografts in tissue banking: systematic review report. Cell Tissue Bank 2016; 17:593-601. [PMID: 27522194 PMCID: PMC5116039 DOI: 10.1007/s10561-016-9570-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Accepted: 07/14/2016] [Indexed: 11/25/2022]
Abstract
Cardiovascular allografts are usually disinfected using antibiotics, but protocols vary significantly between tissue banks. It is likely that different disinfection protocols will not have the same level of efficacy; they may also have varying effects on the structural integrity of the tissue, which could lead to significant differences in terms of clinical outcome in recipients. Ideally, a disinfection protocol should achieve the greatest bioburden reduction with the lowest possible impact on tissue integrity. We conducted a systematic review of methods applied to disinfect cardiovascular tissues. The use of multiple broad spectrum antibiotics in conjunction with an antifungal agent resulted in the greatest reduction in bioburden. Antibiotic incubation periods were limited to less than 24 h, and most protocols incubated tissues at 4 °C, however one study demonstrated a greater reduction of microbial load at 37 °C. None of the reviewed studies looked at the impact of these disinfection protocols on the risk of infection or any other clinical outcome in recipients.
Collapse
|
18
|
Meiser J, Willner M, Schröter T, Hofmann A, Rieger J, Koch F, Birnbacher L, Schüttler M, Kunka D, Meyer P, Faisal A, Amberger M, Duttenhofer T, Weber T, Hipp A, Ehn S, Walter M, Herzen J, Schulz J, Pfeiffer F, Mohr J. Increasing the field of view in grating based X-ray phase contrast imaging using stitched gratings. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2016; 24:379-388. [PMID: 27257876 DOI: 10.3233/xst-160552] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Grating based X-ray differential phase contrast imaging (DPCI) allows for high contrast imaging of materials with similar absorption characteristics. In the last years' publications, small animals or parts of the human body like breast, hand, joints or blood vessels have been studied. Larger objects could not be investigated due to the restricted field of view limited by the available grating area. In this paper, we report on a new stitching method to increase the grating area significantly: individual gratings are merged on a carrier substrate. Whereas the grating fabrication process is based on the LIGA technology (X-ray lithography and electroplating) different cutting and joining methods have been evaluated. First imaging results using a 2×2 stitched analyzer grating in a Talbot-Lau interferometer have been generated using a conventional polychromatic X-ray source. The image quality and analysis confirm the high potential of the stitching method to increase the field of view considerably.
Collapse
|
19
|
Koch FJ, Schröter TJ, Kunka D, Meyer P, Meiser J, Faisal A, Khalil MI, Birnbacher L, Viermetz M, Walter M, Schulz J, Pfeiffer F, Mohr J. Note: Gratings on low absorbing substrates for x-ray phase contrast imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:126114. [PMID: 26724095 DOI: 10.1063/1.4939055] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.
Collapse
|
20
|
Drlica-Wagner A, Albert A, Bechtol K, Wood M, Strigari L, Sánchez-Conde M, Baldini L, Essig R, Cohen-Tanugi J, Anderson B, Bellazzini R, Bloom ED, Caputo R, Cecchi C, Charles E, Chiang J, Angelis AD, Funk S, Fusco P, Gargano F, Giglietto N, Giordano F, Guiriec S, Gustafsson M, Kuss M, Loparco F, Lubrano P, Mirabal N, Mizuno T, Morselli A, Ohsugi T, Orlando E, Persic M, Rainò S, Sehgal N, Spada F, Suson DJ, Zaharijas G, Zimmer S, Abbott T, Allam S, Balbinot E, Bauer AH, Benoit-Lévy A, Bernstein RA, Bernstein GM, Bertin E, Brooks D, Buckley-Geer E, Burke DL, Rosell AC, Castander FJ, Covarrubias R, D’Andrea CB, Costa LND, DePoy DL, Desai S, Diehl HT, Cunha CE, Eifler TF, Estrada J, Evrard AE, Neto AF, Fernandez E, Finley DA, Flaugher B, Frieman J, Gaztanaga E, Gerdes D, Gruen D, Gruendl RA, Gutierrez G, Honscheid K, Jain B, James D, Jeltema T, Kent S, Kron R, Kuehn K, Kuropatkin N, Lahav O, Li TS, Luque E, Maia MAG, Makler M, March M, Marshall J, Martini P, Merritt KW, Miller C, Miquel R, Mohr J, Neilsen E, Nord B, Ogando R, Peoples J, Petravick D, Pieres A, Plazas AA, Queiroz A, Romer AK, Roodman A, Rykoff ES, Sako M, Sanchez E, Santiago B, Scarpine V, Schubnell M, Sevilla I, Smith RC, Soares-Santos M, Sobreira F, Suchyta E, Swanson MEC, Tarle G, Thaler J, Thomas D, Tucker D, Walker AR, Wechsler RH, Wester W, Williams P, Yanny B, Zuntz J. SEARCH FOR GAMMA-RAY EMISSION FROM DES DWARF SPHEROIDAL GALAXY CANDIDATES WITH
FERMI
-LAT DATA. ACTA ACUST UNITED AC 2015. [DOI: 10.1088/2041-8205/809/1/l4] [Citation(s) in RCA: 119] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
21
|
Bechtol K, Drlica-Wagner A, Balbinot E, Pieres A, Simon JD, Yanny B, Santiago B, Wechsler RH, Frieman J, Walker AR, Williams P, Rozo E, Rykoff ES, Queiroz A, Luque E, Benoit-Lévy A, Tucker D, Sevilla I, Gruendl RA, Costa LND, Neto AF, Maia MAG, Abbott T, Allam S, Armstrong R, Bauer AH, Bernstein GM, Bernstein RA, Bertin E, Brooks D, Buckley-Geer E, Burke DL, Rosell AC, Castander FJ, Covarrubias R, D’Andrea CB, DePoy DL, Desai S, Diehl HT, Eifler TF, Estrada J, Evrard AE, Fernandez E, Finley DA, Flaugher B, Gaztanaga E, Gerdes D, Girardi L, Gladders M, Gruen D, Gutierrez G, Hao J, Honscheid K, Jain B, James D, Kent S, Kron R, Kuehn K, Kuropatkin N, Lahav O, Li TS, Lin H, Makler M, March M, Marshall J, Martini P, Merritt KW, Miller C, Miquel R, Mohr J, Neilsen E, Nichol R, Nord B, Ogando R, Peoples J, Petravick D, Plazas AA, Romer AK, Roodman A, Sako M, Sanchez E, Scarpine V, Schubnell M, Smith RC, Soares-Santos M, Sobreira F, Suchyta E, Swanson MEC, Tarle G, Thaler J, Thomas D, Wester W, Zuntz J. EIGHT NEW MILKY WAY COMPANIONS DISCOVERED IN FIRST-YEAR DARK ENERGY SURVEY DATA. ACTA ACUST UNITED AC 2015. [DOI: 10.1088/0004-637x/807/1/50] [Citation(s) in RCA: 401] [Impact Index Per Article: 44.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
22
|
Hüffmeier U, Wätzold M, Mohr J, Schön MP, Mössner R. Successful therapy with anakinra in a patient with generalized pustular psoriasis carrying IL36RN mutations. Br J Dermatol 2015; 170:202-4. [PMID: 23909475 DOI: 10.1111/bjd.12548] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
23
|
Hipp A, Willner M, Herzen J, Auweter S, Chabior M, Meiser J, Achterhold K, Mohr J, Pfeiffer F. Energy-resolved visibility analysis of grating interferometers operated at polychromatic X-ray sources. OPTICS EXPRESS 2014; 22:30394-30409. [PMID: 25606986 DOI: 10.1364/oe.22.030394] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Grating interferometry has been successfully adapted at standard X-ray tubes and is a promising candidate for a broad use of phase-contrast imaging in medical diagnostics or industrial testing. The achievable image quality using this technique is mainly dependent on the interferometer performance with the interferometric visibility as crucial parameter. The presented study deals with experimental investigations of the spectral dependence of the visibility in order to understand the interaction between the single contributing energies. Especially for the choice which type of setup has to be preferred using a polychromatic source, this knowledge is highly relevant. Our results affirm previous findings from theoretical investigations but also show that measurements of the spectral contributions to the visibility are necessary to fully characterize and optimize a grating interferometer and cannot be replaced by only relying on simulated data up to now.
Collapse
|
24
|
Marschall F, Last A, Simon M, Kluge M, Nazmov V, Vogt H, Ogurreck M, Greving I, Mohr J. X-ray Full Field Microscopy at 30 keV. ACTA ACUST UNITED AC 2014. [DOI: 10.1088/1742-6596/499/1/012007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
25
|
Riffelmann M, Mohr J, Hellenbrand W, Wirsing von Koenig CH. Time since last vaccine dose in PCR-positive and PCR-negative children with suspected pertussis to monitor pertussis vaccine effectiveness. Eur J Clin Microbiol Infect Dis 2013; 33:805-8. [DOI: 10.1007/s10096-013-2016-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Accepted: 11/06/2013] [Indexed: 10/26/2022]
|