1
|
Raiskup F, Herber R, Lenk J, Pillunat LE, Spoerl E. Crosslinking with UV-A and riboflavin in progressive keratoconus: From laboratory to clinical practice - Developments over 25 years. Prog Retin Eye Res 2024; 102:101276. [PMID: 38830532 DOI: 10.1016/j.preteyeres.2024.101276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/30/2024] [Accepted: 05/31/2024] [Indexed: 06/05/2024]
Abstract
Changes in the biomechanical and biochemical properties of the human cornea play an important role in the pathogenesis of ectatic diseases. A number of conditions in primarily acquired (keratoconus or pellucid marginal degeneration) or secondarily induced (iatrogenic keratectasia after refractive laser surgeries) ectatic disorders lead to decreased biomechanical stability. Corneal collagen cross-linking (CXL) represents a technique to slow or even halt the progression of ectatic pathologies. In this procedure, riboflavin is applied in combination with ultraviolet A radiation. This interaction induces the production of reactive oxygen species, which leads to the formation of additional covalent bonds between collagen molecules and subsequent biomechanical corneal strengthening. This procedure is so far the only method that partially interferes etiopathogenetically in the treatment of ectatic diseases that slows or stops the process of corneal destabilization, otherwise leading to the need for corneal transplantation. Besides, CXL process increases markedly resistance of collagenous matrix against digesting enzymes supporting its use in the treatment of corneal ulcers. Since the discovery of this therapeutic procedure and the first laboratory experiments, which confirmed the validity of this method, and the first clinical studies that proved the effectiveness and safety of the technique, it has been spread and adopted worldwide, even with further modifications. Making use of the Bunsen-Roscoe photochemical law it was possible to shorten the duration of this procedure in accelerated CXL and thus improve the clinical workflow and patient compliance while maintaining the efficacy and safety of the procedure. The indication spectrum of CXL can be further expanded by combining it with other vision-enhancing procedures such as individualized topographically-guided excimer ablation. Complementing both techniques will allow a patient with a biomechanically stable cornea to regularize it and improve visual acuity without the need for tissue transplantation, leading to a long-term improvement in quality of life.
Collapse
|
2
|
Ramm L, Spoerl E, Terai N, Herber R, Pillunat LE. Association Between Corneal Changes and Retinal Oximetry in Diabetes Mellitus. Clin Ophthalmol 2024; 18:1235-1243. [PMID: 38737594 PMCID: PMC11088381 DOI: 10.2147/opth.s456020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 04/21/2024] [Indexed: 05/14/2024] Open
Abstract
Purpose Diabetes mellitus (DM) causes different corneal changes that are associated with the severity of diabetic retinopathy. To identify the pathophysiological reasons for this, corneal tomography and optical densitometry (COD) were combined with retinal oximetry. Methods Patients with DM and healthy subjects were included in this pilot study. Spatially resolved corneal thickness and COD were assessed using the Pentacam HR (Oculus). The pachymetry difference (PACDiff) was calculated as an indicator of an increase in the peripheral corneal thickness. Oxygen saturation (SO2) of the retinal vessels was measured using the Retinal Vessel Analyzer (Imedos Systems UG). Subsequently, the associations between corneal and retinal parameters were analyzed. Results Data from 30 patients with DM were compared with those from 30 age-matched healthy subjects. In DM, arterial (P = 0.048) and venous (P < 0.001) SO2 levels were increased, and arteriovenous SO2 difference was decreased (P < 0.001). In patients, PACDiff was higher than that in healthy subjects (P < 0.05), indicating a stronger increase in peripheral corneal thickness. The COD was reduced in DM (P = 0.004). The PACDiff of concentric rings with a diameter of 4 mm (r = -0.404; P = 0.033) to 8 mm (r = -0.522; P = 0.004) was inversely correlated with the arteriovenous SO2 difference. Furthermore, PACDiff 4 mm was negatively associated with arterial SO2 (r = -0.389; P = 0.041), and the COD of the peripheral corneal areas correlated positive with arterial SO2 (COD total 10-12 mm: r = 0.408; P = 0.025). Conclusion These associations might indicate a common pathogenesis of corneal and retinal changes in DM, which could be caused by reduced oxygen supply, mitochondrial dysfunction, oxidative stress, and cytokine effects.
Collapse
|
3
|
Stodtmeister R, Menzel A, Klimova A, Herber R, Pillunat KR, Pillunat LE. Measurement of the retinal venous pressure with a new instrument in patients with primary open angle glaucoma. Graefes Arch Clin Exp Ophthalmol 2024; 262:1633-1639. [PMID: 38214734 PMCID: PMC11031493 DOI: 10.1007/s00417-023-06326-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 08/28/2023] [Accepted: 11/20/2023] [Indexed: 01/13/2024] Open
Abstract
PURPOSE To compare the results of retinal venous pressure (RVP) measurement performed with contact lens dynamometry (CLD) and with the new IOPstim. METHODS In this cross-sectional study, we included 36 patients with primary open angle glaucoma with a median age (Q25; Q75) of 74 (64; 77) years (m/f = 18/18), baseline intraocular pressure (IOP): 13.9 (12.2; 15.1) mmHg. Median mean defect: - 5.8 (- 11.9; - 2.6) db. Principle of the IOPstim: an empty balloon with a diameter of 8 mm is positioned on the eye, laterally of the limbus. Under observation of the central retinal vein (CRV), the examiner inflates the balloon. As soon as the CRV starts pulsation, the inflation is stopped and the IOP is measured, equaling the RVP at this moment. In the CLD, the pulsation of the CRV is observed with a contact lens. The RVP is calculated from the attachment force applied when pulsation appears. COURSE OF EXAMINATIONS Three single measurements of RVP in quick succession with both methods. The sequence of the two methods was randomized. The means of the three RVP measurements were compared. RESULTS Pressures in mmHg. RVP: IOPstim: 19.4 ± 5.4 (mean ± SD), CLD: 20.3 ± 5.9. Range of three single measurements: IOPstim: 2.9 ± 1.5, CLD: 2.2 ± 1.1. The differences were RVPIOPstim - RVPCLD = - 0.94 ± 1.15, and approximately normally distributed. Bland-Altman analysis: only one data point was 0.5 mmHg higher than the upper line of agreement. The confidence interval of this line was 0.65 mmHg. Concordance correlation coefficient according to Lin (CCC): 0.96. Intraclass correlation coefficient: both methods, 0.94. CONCLUSION In both methods, the range of the single measurements may be taken as a sign of good reliability, the CCC of 0.96 as a sign of a very good agreement. At the mean, the IOPstim RVP values were 1 mmHg lower than those obtained with the CLD. This difference may be due to the different directions of the prevailing force vectors induced by the instruments. The IOPstim seems applicable in glaucoma diagnostics.
Collapse
|
4
|
Kapelushnik N, Avni-Zauberman N, Herber R, Berger Y, Ezra Nimni O, Abd-Elkader A, Raiskup F, Barequet IS. Corneal cross-linking for treatment of keratoconus relapse in post-keratoplasty eyes. Int Ophthalmol 2023; 43:4027-4034. [PMID: 37436552 DOI: 10.1007/s10792-023-02807-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 06/29/2023] [Indexed: 07/13/2023]
Abstract
PURPOSE Keratoconus relapse after penetrating keratoplasty is a rare condition that may result in severe visual deterioration and corneal graft thinning. Therefore, treatment to stabilize the cornea should be considered. The purpose of this study was to evaluate the safety and efficacy of Corneal Cross-Linking (CXL) in eyes with relapse of keratoconus after penetrating keratoplasty for keratoconus. MATERIALS AND METHODS A retrospective review of eyes that developed keratoconus relapse following a penetrating keratoplasty and treated with CXL. The main outcome measures were change in maximal keratometry (Kmax), best-corrected distance visual acuity (BCVA), thinnest corneal thickness (TCT) and central corneal thickness (CCT), and complications. RESULTS We identified 10 consecutive eyes of 9 patients. Preoperative median BCVA before the CXL and 1 year after the CXL procedure remained stable (p = 0.68). The median (IQR) of Kmax improved from 63.2 (24.9) D before the CXL procedure to 62.2 (27.1) D at 1 year postoperatively (P = 0.028). Median TCT and CCT also remained with no significant change 1 year after CXL. No complications were noted following the procedure. CONCLUSION CXL in eyes with keratoconus relapse after keratoplasty is a safe and effective procedure enabling not only visual stabilization but also might bring keratometry improvement. Routine follow-up after keratoplasty should be performed for early detection of keratoconus relapse and CXL is timely advised when such a relapse is documented.
Collapse
|
5
|
Herber R, Francis M, Spoerl E, Pillunat LE, Raiskup F, Roy AS. Evaluation of Biomechanical Changes After Accelerated Cross-Linking in Progressive Keratoconus: A Prospective Follow-Up Study. Cornea 2023; 42:1365-1376. [PMID: 36727878 DOI: 10.1097/ico.0000000000003219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 11/15/2022] [Indexed: 02/03/2023]
Abstract
PURPOSE The aim of this study was to analyze the biomechanical effect of accelerated corneal cross-linking (9*10) in progressive keratoconus (KC) in comparison to untreated fellow eyes using Scheimpflug-based tonometry (Corvis ST, CVS). METHODS Forty-three eyes of 43 patients with KC showed progressive KC and were treated using accelerated corneal cross-linking. Twenty-five untreated fellow eyes were used as the control group. All eyes were examined biomechanically (CVS) and tomographically (Pentacam) at baseline, after 1-month, 6-month, and 12-month follow-up. Statistical analysis was performed using a linear mixed model. A logistic regression was performed to attribute the effects of changes in each parameter to treatment status (treated or untreated). RESULTS Maximum keratometry values decreased statistically significantly at 12 months by -1.1 D (95 confidence interval: -2.0 to -0.1, P = 0.025) compared with baseline. Thinnest corneal thickness decreased significantly after 1 month ( P < 0.001) and recovered to baseline after 12 months ( P = 0.752). In the corneal cross-linking (CXL) group, biomechanical changes were observed by an increased bIOP, a shorter A2 time, and a lower integrated radius after 1 month (all P < 0.05). No biomechanical and tomographical changes were observed in the control group (all P > 0.05). Logistic regression pointed out that treated eyes can be separated from untreated eyes by differences in bIOP, corneal thickness, A1 velocity, integrated radius, and Kc mean at 1, 6, and 12 months. CONCLUSIONS The alterations in biomechanical parameters indicated a corneal stiffening effect after CXL treatment, which was mostly detectable 1 month after treatment, although corneal thickness was reduced. The logistic regression model showed an adequate separation between CXL-treated and untreated eyes.
Collapse
|
6
|
Jamke M, Herber R, Haase MA, Jasper CS, Pillunat LE, Pillunat KR. PRESERFLO ™ MicroShunt versus trabeculectomy: 1-year results on efficacy and safety. Graefes Arch Clin Exp Ophthalmol 2023; 261:2901-2915. [PMID: 37133501 PMCID: PMC10155172 DOI: 10.1007/s00417-023-06075-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 04/04/2023] [Accepted: 04/15/2023] [Indexed: 05/04/2023] Open
Abstract
PURPOSE To compare the efficacy and safety of the PRESERFLO™ MicroShunt versus trabeculectomy in patients with primary open-angle glaucoma (POAG) after one year. PATIENTS AND METHODS Institutional prospective interventional cohort study comparing eyes with POAG, which had received the PRESERFLO™ MicroShunt versus trabeculectomy. The MicroShunt group was matched with the trabeculectomy group for age, known duration of disease, and number and classes of intraocular pressure (IOP) lowering medications to have similar conjunctival conditions. The study is part of the Dresden Glaucoma and Treatment Study, using a uniform study design, with the same inclusion and exclusion criteria, follow-ups and standardized definitions of success and failure for both procedures. PRIMARY OUTCOME MEASURES mean diurnal IOP (mdIOP, mean of 6 measurements), peak IOP, and IOP fluctuations. SECONDARY OUTCOME MEASURES success rates, number of IOP lowering medications, visual acuity, visual fields, complications, surgical interventions, and adverse events. RESULTS Sixty eyes of 60 patients, 30 in each group, were analyzed after 1-year follow-ups. Median [Q25, Q75] mdIOP (mmHg) dropped from 16.2 [13.8-21.5] to 10.5 [8.9-13.5] in the MicroShunt and from 17.6 [15.6-24.0] to 11.1 [9.5-12.3] in the trabeculectomy group, both without glaucoma medications. Reduction of mdIOP (P = .596), peak IOP (P = .702), and IOP fluctuations (P = .528) was not statistically significantly different between groups. The rate of interventions was statistically significantly higher in the trabeculectomy group, especially in the early postoperative period (P = .018). None of the patients experienced severe adverse events. CONCLUSION Both procedures are equally effective and safe in lowering mdIOP, peak IOP and IOP fluctuations in patients with POAG, one year after surgery. CLINICAL TRIAL REGISTRATION NCT02959242.
Collapse
|
7
|
Herber R, Vinciguerra R, Flockerzi E, Vinciguerra P, Seitz B. Why the Corvis Biomechanical Factor Should Only Be Used for Corneal Ectasia. Transl Vis Sci Technol 2023; 12:24. [PMID: 37223919 DOI: 10.1167/tvst.12.5.24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023] Open
|
8
|
Herber R, Vinciguerra R, Tredici C, Legrottaglie EF, Pillunat LE, Raiskup F, Vinciguerra P. Repeatability of corneal deformation response parameters by dynamic ultra-high-speed Scheimpflug imaging before and after corneal crosslinking. J Cataract Refract Surg 2023; 49:518-524. [PMID: 36700933 DOI: 10.1097/j.jcrs.0000000000001136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 12/17/2022] [Indexed: 01/27/2023]
Abstract
PURPOSE To evaluate the repeatability of deformation corneal response (DCR) parameters before and after corneal crosslinking (CXL) compared with their untreated fellow eyes (uFEs). SETTING University Hospital Carl Gustav Carus, Dresden, Germany; IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy. DESIGN Multicenter, interventional reliability analysis. METHODS 53 eyes of 53 patients with keratoconus who received CXL treatment after the disease progression (CXL group) were included. Patients were measured 3 times using a dynamic Scheimpflug analyzer to determine repeatability before and 1 month after CXL treatment. The uFEs were measured in the same way (uFE group). Reliability of DCR parameters was assessed by a coefficient of repeatability, coefficient of variation, and intraclass correlation coefficient (ICC). RESULTS The repeatability of DCR parameters did not change after CXL compared with the preoperative values for all investigated DCR parameters ( P > .05). In the uFE group, no statistically significant shift was observed regarding the repeatability ( P > .05). An ICC greater than 0.75 was achieved in both groups for almost all parameters. Concerning the biomechanical stiffening induced by CXL, integrated inverse radius and stress-strain index were found to be statistically significantly decreased and increased ( P < .001), respectively, both indicating stiffening. No changes were observed for the uFE group. CONCLUSIONS The study demonstrated highly repeatable measurements of the dynamic Scheimpflug analyzer before and after CXL. The improvement of certain DCR parameters after CXL confirmed the capability of the device to detect the stiffening effect.
Collapse
|
9
|
Raiskup F, Herber R, Lenk J, Ramm L, Wittig D, Pillunat LE, Spoerl E. Corneal Crosslinking With Riboflavin and UVA Light in Progressive Keratoconus: Fifteen-Year Results. Am J Ophthalmol 2023; 250:95-102. [PMID: 36736417 DOI: 10.1016/j.ajo.2023.01.022] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 01/18/2023] [Accepted: 01/19/2023] [Indexed: 02/04/2023]
Abstract
PURPOSE To analyze the 15-year results of corneal crosslinking (CXL) in progressive keratoconus. DESIGN Retrospective follow-up analysis of interventional study patients. METHODS This study included keratoconic eyes with progressive disease treated from 2001 to 2006 at the Department of Ophthalmology, Carl Gustav Carus University Hospital, TU Dresden, Germany. CXL was performed by applying riboflavin and ultraviolet A (UVA) light according to a standard protocol. The best-corrected distance visual acuity (BCVA), slitlamp examination, and corneal topography as well as corneal thickness values were recorded preoperatively and 15 years after the treatment. RESULTS A total of 42 eyes received a complete follow-up of 15 years. The mean age of the patients at baseline was 26.9 (95% CI: 25.0-28.8) years. The maximum keratometry was 61.6 (95% CI: 58.2 - 64.9) diopters (D) preoperatively and 55.1 (95% CI: 51.6-58.4) D postoperatively; the decrease was statistically significant (P < .001). The mean keratometry value changed from 50.3 (95% CI: 48.3-52.4) D to 47.5 (95% CI: 45.3-49.4) D (P < 0.001). Furthermore, the thinnest corneal thickness decreased statistically significantly by 40 (95% CI: 24-56) µm (P < .001). The BCVA improved statistically significantly from 0.4 to 0.2 logMAR after the treatment. Retreatment was needed in 14% of cases. Mild scarring of the superficial stromal corneal layers was observed in 36% of the eyes, and in 67% of them visual acuity was stable or even improved. CONCLUSIONS The CXL procedure proved to be an effective method in the treatment of keratoconic eyes in the progressive stage of the disease, and achieved long-term stabilization without the occurrence of serious complications or side effects.
Collapse
|
10
|
Melcher S, Zimmerer C, Galli R, Golde J, Herber R, Raiskup F, Koch E, Steiner G. Analysis of riboflavin/ultraviolet a corneal cross-linking by molecular spectroscopy. Heliyon 2023; 9:e13206. [PMID: 36747519 PMCID: PMC9898066 DOI: 10.1016/j.heliyon.2023.e13206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 01/19/2023] [Accepted: 01/20/2023] [Indexed: 01/26/2023] Open
Abstract
Corneal cross-linking (CXL) with riboflavin and ultraviolet A light is a therapeutic procedure to restore the mechanical stability of corneal tissue. The treatment method is applied to pathological tissue, such as keratoconus and induces the formation of new cross-links. At present, the molecular mechanisms of induced cross-linking are still not known exactly. In this study, we investigated molecular alterations within porcine cornea tissue after treatment with riboflavin and ultraviolet A light by surface enhanced Raman spectroscopy (SERS). For that purpose, after CXL treatment a thin silver layer was vapor-deposited onto cornea flaps. To explore molecular alterations induced by the photochemical process hierarchical cluster analysis (HCA) was used. The detailed analysis of SERS spectra reveals that there is no general change in collagen secondary structure while modifications on amino acid side chains are the most dominant outcome. The formation of secondary and aromatic amine groups as well as methylene and carbonyl groups were observed. Even though successful cross-linking could not be registered in all treated samples, Raman signals of newly formed chemical groups are already present in riboflavin only treated corneas.
Collapse
|
11
|
Ramm L, Herber R, Lorenz G, Jasper CS, Pillunat LE, Pillunat KR. Evaluation of corneal biomechanical properties using the ocular response analyzer and the dynamic Scheimpflug-Analyzer Corvis ST in high pressure and normal pressure open-angle glaucoma patients. PLoS One 2023; 18:e0281017. [PMID: 36701409 PMCID: PMC9879466 DOI: 10.1371/journal.pone.0281017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 01/12/2023] [Indexed: 01/27/2023] Open
Abstract
PURPOSE To characterize differences in corneal biomechanics in high (HPG) and normal pressure (NPG) primary open-angle glaucoma, and its association to disease severity. METHODS Corneal biomechanical properties were measured using the Ocular Response Analyzer (ORA) and the dynamic Scheimpflug-Analyzer Corvis ST (CST). Disease severity was functionally assessed by automated perimetry (Humphrey field analyzer) and structurally with the Heidelberg Retina Tomograph. To avoid a possible falsification by intraocular pressure, central corneal thickness and age, which strongly influence ORA and CST measurements, group matching was performed. Linear mixed models and generalized estimating equations were used to consider inter-eye correlation. RESULTS Following group matching, 60 eyes of 38 HPG and 103 eyes of 60 NPG patients were included. ORA measurement revealed a higher CRF in HPG than in NPG (P < 0.001). Additionally, the CST parameter integrated radius (P < 0.001) was significantly different between HPG and NPG. The parameter SSI (P < 0.001) representing corneal stiffness was higher in HPG than in NPG. Furthermore, regression analysis revealed associations between biomechanical parameters and indicators of disease severity. In HPG, SSI correlated to RNFL thickness. In NPG, dependencies between biomechanical readings and rim area, MD, and PSD were shown. CONCLUSION Significant differences in corneal biomechanical properties were detectable between HPG and NPG patients which might indicate different pathophysiological mechanisms underlying in both entities. Moreover, biomechanical parameters correlated to functional and structural indices of diseases severity. A reduced corneal deformation measured by dynamic methods was associated to advanced glaucomatous damage.
Collapse
|
12
|
Herber R, Lenk J, Pillunat LE, Raiskup F. Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis. EYE AND VISION 2022; 9:19. [PMID: 35606839 PMCID: PMC9128256 DOI: 10.1186/s40662-022-00290-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 04/25/2022] [Indexed: 11/10/2022]
Abstract
Abstract
Background
To determine the repeatability and agreement using corneal tomography of a swept-source optical coherence tomographer (SS-OCT) compared to a rotating Scheimpflug camera (RSC) in normal eyes and keratoconus (KC) eyes.
Methods
This prospective repeatability analysis was performed at the Department of Ophthalmology of University Hospital Carl Gustav Carus, Dresden, Germany. Forty-three normal and 57 KC eyes were enrolled in the study. Three consecutive measurements were performed by the same operator on each device. Corneal parameters of anterior and posterior corneal surface, such as simulated keratometry (SimK), as well as central and thinnest corneal thickness were evaluated. Repeatability and agreement were assessed by using the coefficient of repeatability and Bland-Altman analysis.
Results
The repeatability of anterior corneal parameters was comparable between RSC and SS-OCT in normal eyes (repeatability < 0.5 D). Repeatability was increased in mild and moderate KC for all parameters using both devices. In moderate KC, repeatability of Kmax was 1.33 D and 0.78 D for RSC and SS-OCT, respectively. Repeatability of posterior corneal parameters was consistently better for SS-OCT. Significant offsets and wide ranges of limits of agreement were found between the devices for SimK and corneal thickness values.
Conclusions
SS-OCT showed highly repeatable measurements of anterior and posterior corneal parameters in normal and KC eyes. Compared to RSC, the SS-OCT had a better repeatability of anterior corneal parameters in mild and moderate KC as well as posterior corneal parameters in all groups. Both devices should not be used interchangeably in the diagnostic process of patients.
Trial registration NCT04251143 at Clinicaltrials.gov, registered on 12 March 2018, https://clinicaltrials.gov/ct2/show/NCT04251143?cond=Keratoconus&cntry=DE&city=Dresden&draw=2&rank=1
Collapse
|
13
|
Herber R, Hasanli A, Lenk J, Vinciguerra R, Terai N, Pillunat LE, Raiskup F. Evaluation of Corneal Biomechanical Indices in Distinguishing Between Normal, Very Asymmetric, and Bilateral Keratoconic Eyes. J Refract Surg 2022; 38:364-372. [PMID: 35686712 DOI: 10.3928/1081597x-20220601-01] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the ability of biomechanical indices provided by the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments) and dynamic Scheimpflug analyzer (Corvis ST; Oculus Optikgeräte GmbH) to distinguish between normal eyes and eyes with very asymmetric ectasia (VAE) and mild and moderate keratoconus. METHODS This prospective, observational, and monocentric study included normal eyes (defined as keratoconus percentage index < 60, Belin/Ambrósio total deviation value [BAD-D] < 1.6, inferior-superior keratometry [I-S value] < 1.45 and maximum keratometry [Kmax] < 47) and eyes with clinical bilateral keratoconus (mild and moderate) and VAE (defined as unilateral keratoconus, where one eye showed a clinical keratoconus and the fellow eye was topographically normal [VAE-NT] or topographically and tomographically normal [VAE-NTT]). All eyes were measured by the Pentacam (Oculus Optikgeräte GmbH), ORA, and Corvis ST. Receiver operating characteristic curve analysis was performed to test the diagnostic ability. RESULTS Fifty-eight normal eyes and 238 ectatic eyes were included. The highest area under the curve (AUC) was provided by the Corvis Biomechanical Index (CBI) with an AUC of 0.979, followed by ORA corneal resistance factor (0.865), and corneal hysteresis (0.824) separating normal eyes from all ectatic subgroups. The AUC of the CBI was statistically significantly higher than all other parameters (DeLong test, P < .001). A sensitivity of 100% and 70.9%, respectively, and a specificity of 93.1% was found to distinguish normal eyes from VAE-NT and VAE-NTT using a cut-off value of 0.2. CONCLUSIONS The assessment of biomechanical properties is an additional important method to evaluate corneal ectasia independent of its stage. The CBI provides further information for ectasia screening in cases where corneal topography and tomography are clinically not suspicious by using a cutoff of 0.2. [J Refract Surg. 2022;38(6):364-372.].
Collapse
|
14
|
Pillunat KR, Herber R, Haase MA, Jamke M, Jasper CS, Pillunat LE. PRESERFLO™ MicroShunt versus trabeculectomy: first results on efficacy and safety. Acta Ophthalmol 2022; 100:e779-e790. [PMID: 34331505 DOI: 10.1111/aos.14968] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/21/2021] [Accepted: 06/17/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE To report efficacy and safety outcomes of the PRESERFLO™ MicroShunt compared with trabeculectomy, the current gold-standard treatment for advanced glaucoma, in the early and intermediate postoperative period. METHODS Institutional prospective interventional cohort study of primary open-angle glaucoma (POAG) patients scheduled for the PRESERFLO™ MicroShunt. The comparison group were POAG patients who had had received trabeculectomy and were matched for age, known duration of disease, number and classes of intraocular pressure (IOP)-lowering medications to ensure a similar conjunctival condition. The study is part of the Dresden Glaucoma and Treatment Study (DGTS), was not randomized, but used a uniform study design, with the same inclusion and exclusion criteria as well as standardized definitions of success and failure. MAIN OUTCOME MEASURES mean diurnal IOP (mdIOP, mean of 6 measurements), diurnal peak IOP, diurnal IOP fluctuations, glaucoma medical therapy, success rates, visual acuity, visual fields, surgical complications and interventions, and severe adverse events. RESULTS Fifty-two eyes of 52 patients, 26 in each group, were analysed. At 6 months, median [Q25, Q75] mdIOP was 10.8 [9.5-12.2] mmHg in the microshunt and 10.3 [7.6-11.8] mmHg in the trabeculectomy group. Reduction in mdIOP (p = 0.458), peak diurnal IOP (p = 0.539), and median diurnal fluctuation (p = 0.693) was not statistically significantly different between groups. The rate of interventions was statistically significantly higher in the trabeculectomy compared with the microshunt group (p = 0.004). None of the patients experienced severe adverse events. CONCLUSION Both procedures are equally effective and safe in lowering mdIOP in patients with POAG. Because the microshunt is less invasive with less follow-up and interventions needed postoperatively, it might be recommended earlier in the treatment of glaucoma.
Collapse
|
15
|
Waibel S, Herber R, Ramm L, Jasper CS, Pillunat LE, Pillunat KR. 2-Jahres-Ergebnisse nach transskleraler MicroPulse-Lasertherapie bei Patienten mit primärem Offenwinkelglaukom. Klin Monbl Augenheilkd 2022; 239:786-792. [DOI: 10.1055/a-1782-7941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Zusammenfassung
Hintergrund Untersuchung der langfristigen Effizienz und Sicherheit der transskleralen Lasertherapie (TLT) mittels MicroPulse über 24 Monate bei Patienten mit primärem
Offenwinkelglaukom (POWG).
Material und Methoden In dieser prospektiven interventionellen Fallserie wurden die Daten von 44 Augen von medikamentös behandelten POWG-Patienten ausgewertet, die eine
MicroPulse-TLT erhielten, um eine weitere Senkung des Augeninnendrucks (IOD) zu erreichen. Es wurden die Reduktion des 24-h-IODs, der zirkadianen IOD-Fluktuationen und der IOD-Spitzen nach
3, 12 und 24 Monaten untersucht. Zudem sollten postoperative Komplikationen, die Misserfolgsquote und Einflussfaktoren auf den Therapieerfolg analysiert werden.
Ergebnisse Der IOD ist von 16,1 ± 3,4 mmHg präoperativ auf 13,0 ± 2,9 mmHg (n = 31; p < 0,001) nach 3 Monaten, 12,3 ± 3,0 mmHg (n = 27; p < 0,001) nach 12 Monaten und
13,1 ± 2,6 mmHg (n = 23; p < 0,001) nach 24 Monaten gesunken. Nach 24 Monaten erreichten 23 Augen (52%) ihren individuellen Zieldruck. Es traten keine schwerwiegenden postoperativen
Komplikationen auf. Es konnten keine Einflussfaktoren auf den Therapieerfolg identifiziert werden. Das häufigste Therapieversagen war innerhalb der ersten 3 postoperativen Monate zu
beobachten und blieb danach nahezu stabil.
Schlussfolgerung Die MicroPulse-TLT zeigt eine gute IOD-Senkung bei Patienten mit primärem Offenwinkelglaukom und maximal tolerierter drucksenkender Lokaltherapie, wobei etwa 50% der
Augen ihren individuellen Zieldruck erreichten.
Collapse
|
16
|
Herber R, Graehlert X, Raiskup F, Veselá M, Pillunat LE, Spoerl E. Statistical Evaluation of Correlated Measurement Data in Longitudinal Setting Based on Bilateral Corneal Cross-Linking. Curr Eye Res 2022; 47:995-1002. [PMID: 35354347 DOI: 10.1080/02713683.2022.2052105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
PURPOSE In ophthalmology, data from both eyes of a person are frequently included in the statistical evaluation. This violates the requirement of data independence for classical statistical tests (e.g. t-Test or analysis of variance (ANOVA)) because it is correlated data. Linear mixed models (LMM) were used as a possibility to include the data of both eyes in the statistical evaluation. METHODS The LMM is available for a variety of statistical software such as SPSS or R. The application was applied to a retrospective longitudinal analysis of an accelerated corneal cross-linking (ACXL (9*10)) treatment in progressive keratoconus (KC) with a follow-up period of 36 months. Forty eyes of 20 patients were included, whereas sequential bilateral CXL treatment was performed within 12 months. LMM and ANOVA for repeated measurements were used for statistical evaluation of topographical and tomographical data measured by Pentacam (Oculus, Wetzlar, Germany). RESULTS Both eyes were classified into a worse and better eye concerning corneal topography. Visual acuity, keratometric values and minimal corneal thickness were statistically significant between them at baseline (p < 0.05). A significant correlation between worse and better eye was shown (p < 0.05). Therefore, analyzing the data at each follow-up visit using ANOVA partially led to an overestimation of the statistical effect that could be avoided by using LMM. After 36 months, ACXL has significantly improved BCVA and flattened the cornea. CONCLUSION The evaluation of data of both eyes without considering their correlation using classical statistical tests leads to an overestimation of the statistical effect, which can be avoided by using the LMM.
Collapse
|
17
|
Pillunat KR, Herber R, Pillunat LE. Corneal Biomechanics in Glaucoma. Klin Monbl Augenheilkd 2022; 239:158-164. [PMID: 35211937 DOI: 10.1055/a-1667-6648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Now that is possible to measure the biomechanical parameters of the cornea in vivo, scientific and clinical interest has increased in changes in these parameters in glaucoma. These parameters may act as biomarkers for early diagnosis, but also serve to emphasize the increased vulnerability to intraocular pressure, reduced blood flow or changing ocular perfusion pressure. Measuring and interpreting these parameters may help in achieving better and individually tailored glaucoma management.
Collapse
|
18
|
Vinciguerra R, Herber R, Wang Y, Zhang F, Zhou X, Bai J, Yu K, Chen S, Fang X, Raiskup F, Vinciguerra P. Corneal Biomechanics Differences Between Chinese and Caucasian Healthy Subjects. Front Med (Lausanne) 2022; 9:834663. [PMID: 35280913 PMCID: PMC8914014 DOI: 10.3389/fmed.2022.834663] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 01/31/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose The aim of this study was to evaluate the difference between Caucasian and Chinese healthy subjects with regards to Corvis ST dynamic corneal response parameters (DCRs). Methods Two thousand eight hundred and eighty-nine healthy Caucasian and Chinese subjects were included in this multicenter retrospective study. Subsequently, Chinese eyes were matched to Caucasians by age, intraocular pressure (IOP), and Corneal Thickness (CCT) using a case-control matching algorithm. The DCRs assessed were Deformation Amplitude (DA) Applanation 1 velocity (A1v), integrated radius (1/R), deformation amplitude ratio (DAratio), stiffness parameter at applanation 1 (SPA1), ARTh (Ambrósio's Relational Thickness to the horizontal profile), and the novel Stress Strain Index (SSI). Results After age-, CCT-, and IOP- matching, 503 Chinese were assigned to 452 Caucasians participants. Statistical analysis showed a statistical significant difference between Chinese and Caucasian Healthy subjects in the values of SPA1 (p = 0.008), Arth (p = 0.008), and SSI (p < 0.001). Conversely, DA, A1v, DAratio, and 1/R were not significantly different between the two ethnical groups (p > 0.05). Conclusion We found significant differences in the values of the DCRs provided by the Corvis ST between Chinese and Caucasian healthy subjects.
Collapse
|
19
|
Pillunat KR, Herber R, Wolfram S, Jasper CS, Waibel S, Pillunat LE. Efficacy of Selective Laser Trabeculoplasty on Circadian Intraocular Pressure Following Trabeculectomy in Advanced Primary Open-angle Glaucoma. J Glaucoma 2022; 31:96-101. [PMID: 34919063 DOI: 10.1097/ijg.0000000000001971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Accepted: 11/29/2021] [Indexed: 11/25/2022]
Abstract
PRCIS In about 50% of post-trabeculectomy (TE) eyes, selective laser trabeculoplasty (SLT) is effective in further lowering intraocular pressure (IOP). PURPOSE To investigate the efficacy and safety of SLT in post-TE eyes, uncontrolled on maximum tolerated medication, and/or with progression of visual field loss. PATIENTS AND METHODS This retrospective study consecutively included post-TE eyes of patients diagnosed with primary open-angle glaucoma who had been treated with 360 degrees SLT and had a follow-up after 12 months. Primary endpoints were the reduction of mean diurnal intraocular pressure (mdIOP, mean of 6 measurements), peak IOP, and diurnal IOP fluctuations. Secondary outcomes were factors influencing IOP reduction, SLT success, and failure rates. RESULTS Forty-three eyes of 43 patients were included. During the first year, 10 eyes (23%) needed additional procedures to reduce mdIOP and were accounted as failures and excluded from final analysis. Of the remaining 33 eyes (77%) mdIOP [Q25, Q75] dropped from 15.2 [12.2 to 16.5] to 13.2 [11.6 to 15.3] mm Hg (P=0.027), 23 eyes (54%) showed a sufficient mdIOP reduction, 1 year after SLT. CONCLUSION SLT is effective and safe in lowering mdIOP to target IOP in about 50% of eyes after prior incisional glaucoma surgery.
Collapse
|
20
|
Lenk J, Herber R, Oswald C, Spoerl E, Pillunat LE, Raiskup F. Risk Factors for Progression of Keratoconus and Failure Rate After Corneal Cross-linking. J Refract Surg 2021; 37:816-823. [PMID: 34914558 DOI: 10.3928/1081597x-20210830-01] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess the occurrence of risk factors for progression of keratoconus and failure rate after corneal cross-linking (CXL) in patients with progressive keratoconus. METHODS This retrospective study observed 230 eyes of 173 patients with a minimum follow-up of 36 months after CXL. A total of 185 eyes underwent CXL once (80%) (control) and 45 (20%) underwent this treatment more than once (Re-CXL-group). Subgroup analysis included standard CXL with the Dresden protocol (S-CXL group, n = 120) and accelerated CXL with a reduced radiation time of 10 minutes and a higher radiation power of 9 mW/cm2 (A-CXL group, n = 110). Risk factors of interest were age, maximum keratometry (Kmax), minimum corneal thickness (MCT), sex, and atopy (including allergic bronchial asthma, food allergy, allergic rhinitis, and neurodermatitis). RESULTS Follow-up for the control group was 76.0 ± 33.2 months. Re-CXL was performed after 46.2 ± 34.1 months overall and after 62.6 ± 41.9 months in the S-CXL subgroup and 29.2 ± 19.2 months in the A-CXL subgroup (P = .02). Kaplan-Meier analysis revealed a cumulative prediction rate of success after CXL of 92.5% (S-CXL) and 86.4% (A-CXL) after 36 months (P = .103). A high preoperative Kmax value (odds ratio = 1.056, P = .003 and odds ratio = 1.067, P = .028) in both subgroups and the presence of neurodermatitis combined with other atopic diseases in the A-CXL group (odds ratio = 11.662, P = .003) were significant risk factors for new progression of keratoconus after CXL. CONCLUSIONS Risk factors for progression of keratoconus after CXL are both high preoperative Kmax values and the presence of neurodermatitis combined with other atopic diseases. Patients with severe atopy should receive the S-CXL procedure. [J Refract Surg. 2021;37(12):816-823.].
Collapse
|
21
|
Lenk J, Herber R, Raiskup F, Pillunat LE, Spörl E. [Principles of corneal cross-linking : Presentation based on the development of the various treatment protocols]. Ophthalmologe 2021; 119:332-341. [PMID: 34882268 DOI: 10.1007/s00347-021-01538-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/08/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Corneal cross-linking (CXL) is used to treat corneal ectatic diseases. The aim is to improve the reduced consolidation of the cornea in order to halt further corneal protrusion and therefore subsequent deterioration of the optical imaging proportions. MATERIAL AND METHODS In this article the principles of corneal cross-linking based on riboflavin and UV light are presented including recent research results. Furthermore, the most important treatment protocols including standard CXL (S-CXL), accelerated CXL (A-CXL), transepithelial CXL (TE-CXL) and the approach of the CXL procedure for thin corneas are explained. RESULTS The CXL method depends on four major components, the riboflavin solution, oxygen, UV light and the availability of cross-linking sites on the collagen tissue. According to the present state of knowledge, the photochemical process of the CXL method induces covalent bonds between the fibrils and proteoglycans and thus stabilizes the collagen fibers, resulting in corneal consolidation. In addition to the S‑CXL, which has proven its effectiveness and safety in a large number of studies, there are other treatment protocols that have been developed based on the Bunsen-Roscoe law of reciprocity. The A‑CXL protocol has the advantage of having a shorter irradiation time but it seems to be less effective than the S‑CXL protocol concerning the increase in corneal stiffness. The use of TE-CXL has so far not yet gained acceptance in the clinical practice. CONCLUSION The CXL procedures primarily aim to stabilize the cornea. In the future, in addition to stabilization of the cornea, simultaneous improvement of visual acuity will be the main focus.
Collapse
|
22
|
Stodtmeister R, Wetzk E, Herber R, Pillunat KR, Pillunat LE. Measurement of the retinal venous pressure with a new instrument in healthy subjects. Graefes Arch Clin Exp Ophthalmol 2021; 260:1237-1244. [PMID: 34499248 PMCID: PMC8913447 DOI: 10.1007/s00417-021-05374-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 07/15/2021] [Accepted: 08/06/2021] [Indexed: 11/09/2022] Open
Abstract
Background The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared. Methods The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim. Principle: a deflated balloon of 8 mm diameter—placed on the sclera laterally of the cornea—is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg). Results Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim. Conclusion This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors.
Collapse
|
23
|
Herber R, Pillunat LE, Raiskup F. Development of a classification system based on corneal biomechanical properties using artificial intelligence predicting keratoconus severity. EYE AND VISION 2021; 8:21. [PMID: 34059127 PMCID: PMC8167942 DOI: 10.1186/s40662-021-00244-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 05/06/2021] [Indexed: 01/03/2023]
Abstract
Background To investigate machine-learning (ML) algorithms to differentiate corneal biomechanical properties between different topographical stages of keratoconus (KC) by dynamic Scheimpflug tonometry (CST, Corvis ST, Oculus, Wetzlar, Germany). In the following, ML models were used to predict the severity in a training and validation dataset. Methods Three hundred and eighteen keratoconic and one hundred sixteen healthy eyes were included in this monocentric and cross-sectional pilot study. Dynamic corneal response (DCR) and corneal thickness related (pachymetric) parameters from CST were chosen by appropriated selection techniques to develop a ML algorithm. The stage of KC was determined by the topographical keratoconus classification system (TKC, Pentacam, Oculus). Patients who were classified as TKC 1, TKC 2 and TKC 3 were assigned to subgroup mild, moderate, and advanced KC. If patients were classified as TKC 1–2, TKC 2–3 or TKC 3–4, they were assigned to subgroups according to the normative range of further corneal indices (index of surface variance, keratoconus index and minimum radius). Patients classified as TKC 4 were not included in this study due to the limited amount of cases. Linear discriminant analysis (LDA) and random forest (RF) algorithms were used to develop the classification models. Data were divided into training (70% of cases) and validation (30% of cases) datasets. Results LDA model predicted healthy, mild, moderate, and advanced KC eyes with a sensitivity (Sn)/specificity (Sp) of 82%/97%, 73%/81%, 62%/83% and 68%/95% from a validation dataset, respectively. For the RF model, a Sn/Sp of 91%/94%, 80%/90%, 63%/87%, 72%/95% could be reached for predicting healthy, mild, moderate, and advanced KC eyes, respectively. The overall accuracy of LDA and RF was 71% and 78%, respectively. The accuracy for KC detection including all subgroups of KC severity was 93% in both models. Conclusion The RF model showed good accuracy in predicting healthy eyes and various stages of KC. The accuracy was superior with respect to the LDA model. The clinical importance of the models is that the standalone dynamic Scheimpflug tonometry is able to predict the severity of KC without having the keratometric data. Trial registration NCT04251143 at Clinicaltrials.gov, registered at 12 March 2018 (Retrospectively registered). Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00244-4.
Collapse
|
24
|
Waibel S, Thomaschewski G, Herber R, Pillunat LE, Pillunat KR. Comparison of Different Nutritional and Lifestyle Factors between Glaucoma Patients and an Age-Matched Normal Population. Klin Monbl Augenheilkd 2021; 238:1328-1334. [PMID: 33853194 DOI: 10.1055/a-1396-4749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE To compare nutritional and lifestyle factors between glaucoma patients and an age-matched control group. METHODS One hundred and ninety (190) glaucoma patients were enrolled in this study. The control group comprised 97 age-matched participants. Data on physical activity, nicotine smoking, and several nutritional habits like coffee and alcohol consumption as well as high-salt and high-protein intake were collected using a standardised questionnaire. RESULTS Age and gender were not statistically significantly different between the groups. There was a tendency for higher physical activity in the glaucoma group in comparison to the control group (47.3 vs. 35.4%; p = 0.056). Statistically significantly more glaucoma patients were nonsmokers (n = 169; 89.4%) compared to the control group (n = 64; 66.7%; p = 0.001). Glaucoma patients were also more often teetotal compared to the control group (21.6% compared to 14.4%; p < 0.001). Similarly, more glaucoma patients drank larger amounts of coffee in comparison to the control group (p = 0.001). One hundred and seventy-six (96.7%) glaucoma patients and 88 (90.7%) control subjects had high-protein intake (p = 0.035). High-salt intake was significantly lower in the glaucoma group (69.3 vs. 73.2%; p = 0.018). Of the 190 glaucoma patients, 81 had early visual field impairments (MD > - 6 dB) and 109 patients had moderate (MD between - 6 dB and - 12 dB) to severe (MD < - 12 dB) visual field defects. The severity of visual field defects, whether early, moderate, or severe, had no statistically significant impact on lifestyle parameters. CONCLUSION Contrary to our original hypothesis that glaucoma patients would tend to follow an unhealthier lifestyle than the control group, the opposite was seen. Presumably, the cause of this healthier lifestyle is the desire to contribute positively through the course of the disease.
Collapse
|
25
|
Herber R, Vinciguerra R, Lopes B, Raiskup F, Pillunat LE, Vinciguerra P, Ambrósio R. Repeatability and reproducibility of corneal deformation response parameters of dynamic ultra-high-speed Scheimpflug imaging in keratoconus. J Cataract Refract Surg 2020; 46:86-94. [PMID: 32050237 DOI: 10.1016/j.jcrs.2019.08.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
PURPOSE To assess the repeatability and reproducibility of dynamic corneal response (DCR) parameters obtained by ultra-high-speed Scheimpflug imaging (Corvis ST); in keratoconic patients. SETTING Clinics in Germany, Italy, and Brazil. DESIGN Prospective, observational study. METHODS Patients were examined 3 times using 2 different dynamic Scheimpflug analyzers (Corvis ST) to obtain repeatability and reproducibility. The reliability of intraocular pressure (IOP), biomechanically corrected IOP (bIOP), pachymetry, and DCR parameters were assessed by the coefficient of repeatability, coefficient of variation (CoV), intraclass correlation coefficient (ICC), and within-subject standard deviation (sw). RESULTS Ninety-eight eyes from 98 KC patients were included. The sw of the IOP and bIOP did not exceed 1.1 mm Hg. A CoV less than 10% was found in all DCR parameters and had a good to excellent accordance regarding the ICC. The Corvis Biomechanical Index showed an excellent repeatability and interdevice reproducibility of 0.918 and 0.827, respectively. Also, the tomographic biomechanical index showed an excellent repeatability of 3 Corvis ST and Pentacam measurements (ICC = 0.997). With regard to keratoconic severity, a significant increase in the CoV was found between mild and moderate stages compared with the advanced stage. Nevertheless, it did not exceed 10% of the CoV in severe keratoconic eyes. CONCLUSION Corvis ST measurements in keratoconic eyes were highly repeatable and reproducible.
Collapse
|