1
|
Reis-Neta GRD, Ricomini-Filho AP, Martorano-Fernandes L, Vargas-Moreno VF, Cury AADB, Marcello-Machado RM. Effect of hydroxyapatite nanoparticles coating of titanium surface on biofilm adhesion: An in vitro study. Arch Oral Biol 2024; 164:105986. [PMID: 38723421 DOI: 10.1016/j.archoralbio.2024.105986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 04/23/2024] [Accepted: 04/25/2024] [Indexed: 06/06/2024]
Abstract
AIM To evaluate the adhesion of mono and duospecies biofilm on a commercially available dental implant surface coated with hydroxyapatite nanoparticles (nanoHA). MATERIAL AND METHODS Titanium discs were divided into two groups: double acid-etched (AE) and AE coated with nanoHA (NanoHA). Surface characteristics evaluated were morphology, topography, and wettability. Mono and duospecies biofilms of Streptococcus sanguinis (S. sanguinis) and Candida albicans (C. albicans) were formed. Discs were exposed to fetal bovine serum (FBS) to form the pellicle. Biofilm was growth in RPMI1640 medium with 10% FBS and 10% BHI medium for 6 h. Microbial viability was evaluated using colony-forming unit and metabolic activity by a colorimetric assay of the tetrazolium salt XTT. Biofilm architecture and organization were evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). RESULTS AE surface had more pores, while NanoHA had even nanoHA crystals distribution. Roughness was similar (AE: 0.59 ± 0.07 µm, NanoHA: 0.69 ± 0.18 µm), but wettability was different (AE: Θw= 81.79 ± 8.55°, NanoHA: Θw= 53.26 ± 11.86°; P = 0.01). NanoHA had lower S. sanguinis viability in monospecies biofilm (P = 0.007). Metabolic activity was similar among all biofilms. In SEM both surfaces on C. albicans biofilm show a similar distribution of hyphae in mono and duospecies biofilms. AE surface has more S. sanguinis than the NanoHA surface in the duospecies biofilm. CLSM showed a large proportion of live cells in all groups. CONCLUSIONS The nanoHA surface reduced the adhesion of S. sanguinis biofilm but did not alter the adhesion of C. albicans or the biofilm formed by both species.
Collapse
|
2
|
Haude S, Matthes R, Pitchika V, Holtfreter B, Schlüter R, Gerling T, Kocher T, Jablonowski L. In-vitro biofilm removal from TiUnite® implant surface with an air polishing and two different plasma devices. BMC Oral Health 2024; 24:558. [PMID: 38741081 DOI: 10.1186/s12903-024-04230-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 04/04/2024] [Indexed: 05/16/2024] Open
Abstract
BACKGROUND We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.
Collapse
|
3
|
Adeeb Gabra EN, Sadek HMA, Hamdy AM, Wahsh MM. Effect of surface treatment and resin cement type on the bond strength of polyetheretherketone to lithium disilicate ceramic. BMC Oral Health 2024; 24:513. [PMID: 38698366 PMCID: PMC11064278 DOI: 10.1186/s12903-024-04269-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 04/17/2024] [Indexed: 05/05/2024] Open
Abstract
BACKGROUND This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 μm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.
Collapse
|
4
|
Naik R, Allu SG, Purnima D. PP/Jute Fiber Composites: Effect of Biological Route of Surface Treatment and Content of Jute on Composites. Appl Biochem Biotechnol 2024; 196:2869-2880. [PMID: 37335456 DOI: 10.1007/s12010-023-04589-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/26/2023] [Indexed: 06/21/2023]
Abstract
Jute as a fiber has many applications. It is also used in polymers as reinforcement due to its good tensile properties. However, when it is used in polymer matrices, there is a lack of adhesion between the polymer and jute fiber. Surface treatment of fiber using chemicals has been found to improve the properties. However, the use of chemicals causes environmental pollution, when these chemicals are discharged into the environment. In this paper, an attempt has been made to study the effect of the biological route to surface treat the jute fiber. The effect of surface treatment on the morphology of jute was examined. A comparative study was on the crystalline, thermal, and tensile fracture morphology of the composites to understand the effect of the incorporation of untreated and treated jute fibers in polypropylene (PP).
Collapse
|
5
|
Antal MA, Kiscsatári R, Braunitzer G, Piffkó J, Varga E, Eliaz N. Assessment of a novel electrochemically deposited smart bioactive trabecular coating (SBTC®): a randomized controlled clinical trial. Head Face Med 2024; 20:24. [PMID: 38627712 PMCID: PMC11022491 DOI: 10.1186/s13005-024-00426-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 03/28/2024] [Indexed: 04/19/2024] Open
Abstract
OBJECTIVES A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.
Collapse
|
6
|
Doğan İ, Karaman E. How the repair bonding strength of hybrid ceramic CAD/CAM blocks is influenced by the use of surface treatments and universal adhesives. Dent Mater J 2024; 43:312-319. [PMID: 38432950 DOI: 10.4012/dmj.2023-237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024]
Abstract
We examined how different methods of surface treatment and different universal adhesives with or without extra silane affected the repair bonding strength of hybrid ceramic CAD/CAM restorations. Cerasmart specimens (n=320) were subjected to thermocycling and assigned to the following surface pretreatment protocols: control, diamond bur (DB), hydrofluoric acid (HF), and tribochemical silica coating (TSC). Half the specimens received a coating of silane, followed by application of the universal adhesives Futurabond M+ (FMU), Tokuyama Universal Bond (TUB), Single Bond Universal (SBU), or Clearfil Universal Bond Quick (CUQ) (n=10). A hybrid composite resin was used to simulate repair; then the specimens underwent further thermocycling. Shear bond strength (SBS) was determined and modes of failure were examined. The TSC-CUQ silane (-) group showed the highest SBS values. The best repairs were obtained when the surface was treated with TSC, with the exception of the DB-TUB silane (-) group. TUB increased SBS more than the other adhesives. Additional silane decreased SBS in the HF-TUB and TSC-CUQ groups, while increasing it in the TSC-TUB and DB-FMU groups (p<0.05).
Collapse
|
7
|
Onuma H, Inokoshi M, Xu K, Minakuchi S. Fracture strength of porcelain veneer on surface-treated zirconia. Dent Mater J 2024; 43:263-268. [PMID: 38382941 DOI: 10.4012/dmj.2023-139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
In this study, we investigated the effects of surface treatment on the fracture strength of porcelain-veneered zirconia. Highly translucent 4 mol% yttria-stabilized zirconia disks (KATANA HT, Kuraray Noritake Dental) were divided into three surface-treatment groups: 1)as-sintered, 2) alumina sandblasted, and 3) ground. Crystallographic and surface-roughness analyses were conducted for each group. Veneering ceramics (Cerabien ZR, Kuraray Noritake Dental) were applied to the zirconia surfaces. The fracture strengths of the porcelain-veneered zirconia disks were measured using biaxial flexural-strength tests. Crystallographic analysis revealed that grinding and sandblasting increased the fractions of the monoclinic and rhombohedral zirconia phases. The ground specimens had a higher surface roughness than the sandblasted specimens. Weibull analysis showed no significant differences in biaxial flexural strength among the three groups. The results suggest that these surface treatments do not affect the fracture strength of porcelain-veneered zirconia.
Collapse
|
8
|
Duan X, Yang Y, Zhang T, Zhu B, Wei G, Li H. Research progress of metal biomaterials with potential applications as cardiovascular stents and their surface treatment methods to improve biocompatibility. Heliyon 2024; 10:e25515. [PMID: 38375258 PMCID: PMC10875388 DOI: 10.1016/j.heliyon.2024.e25515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 01/23/2024] [Accepted: 01/29/2024] [Indexed: 02/21/2024] Open
Abstract
Facing the growing issue of cardiovascular diseases, metallic materials with higher tensile strength and fatigue resistance play an important role in treating diseases. This review lists the advantages and drawbacks of commonly used medical metallic materials for vascular stents. To avoid post-procedural threats such as thrombosis and in-stent restenosis, surface treatments, and coating methods have been used to further improve the biocompatibility of these materials. Surface treatments including laser, plasma treatment, polishing, oxidization, and fluorination can improve biocompatibility by modifying the surface charges, surface morphology, and surface properties of the material. Coating methods based on polymer coatings, carbon-based coatings, and drug-functional coatings can regulate the surface properties, and also serve as an effective barrier to the interaction of metallic biomaterial surfaces with biomolecules, which can be used to improve corrosion resistance and stability, as well as improve their biocompatibility. Biocompatibility serves as the most fundamental property of cardiovascular stents, and maintaining the excellent and stable biocompatibility of cardiovascular stent surfaces is a current research bottleneck. Few reviews have been published on metallic biomaterials as cardiovascular stents and their surface treatments. For the purpose of advancing research on cardiovascular stents, common metal biomaterials, surface treatment methods, and coating methods to improve biocompatibility and comprehensive properties of the materials are described in this review. Finally, we suggest future directions for stent development, including continuously improving the durability and stability of permanent stents, accelerating the development of biodegradable stents, and strengthening feedback to improve the safety and reliability of cardiovascular stents.
Collapse
|
9
|
Steiner R, Scott S, Wiesmüller V, Lepperdinger U, Steinmassl O, Schnabl D, Schwindling S. Effect of zirconia surface conditioning before glazing on the wear of opposing enamel: an in vitro study. Clin Oral Investig 2024; 28:128. [PMID: 38294555 DOI: 10.1007/s00784-024-05522-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 01/18/2024] [Indexed: 02/01/2024]
Abstract
OBJECTIVES This in vitro study aimed to evaluate the wear of natural teeth opposing 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) with different surface conditions. MATERIALS AND METHODS Sixty 3Y-TZP specimens were randomly assigned to six groups (n = 10), differing in surface condition. In three groups, the samples underwent glazing-with the glaze applied to roughened (i.e., 106-µm-grit diamond-finished), as-sintered, and polished zirconia. The three remaining groups consisted of unglazed specimens: solely polished samples and diamond-finished samples (106-µm-grit and 46-µm-grit) without further conditioning. Two-body wear was evaluated at extracted, non-carious molars (n = 60), which served as antagonists in chewing simulation (10,000 masticatory cycles, 49N load). As a control, natural teeth with intact enamel surfaces were tested against natural molars (n = 10). All samples were 3D-scanned before and after the chewing simulation (7 Series, Straumann). Volume loss was calculated (Inspect Software, GOM), and statistically analyzed (SPSS Statistics 24, IBM). RESULTS Volume loss of the natural antagonists decreased in the following order: 106-µm-grit diamond-finished zirconia (4.6 ± 2.5 mm3), glazed 106-µm-grit diamond-finished zirconia (3.8 ± 1.1 mm3), glazed as-sintered zirconia (3.5 ± 0.9 mm3), 46-µm-grit diamond-finished zirconia (1.7 ± 0.6 mm3), control (1.6 ± 0.7 mm3), glazed polished zirconia (1.4 ± 0.5 mm3), and solely polishing (0.4 ± 0.2 mm3). Even when polishing the surfaces before glazing, volume loss was not mitigated to the same extent as after polishing alone. CONCLUSIONS The zirconia surface condition beneath the glazing influences antagonist wear. Although polishing before glazing resulted in acceptable levels of antagonist wear, this approach did not yield as favorable results as polishing alone. CLINICAL RELEVANCE For operators favoring glazing, pre-polishing the zirconia surface could be advantageous to reduce wear.
Collapse
|
10
|
Maqbool B, Rego HMC, Santos GC, Ari N, Santos MJMC. Effect of different surface treatment protocols on the bond strength between lithium disilicate and resin cements. Odontology 2024; 112:74-82. [PMID: 37036616 DOI: 10.1007/s10266-023-00809-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 03/24/2023] [Indexed: 04/11/2023]
Abstract
Because the use of hydrofluoric acid (HF) poses health risks if handled improperly, many clinicians prefer to have the ceramic restorations pre-etched in dental laboratories. However, during the try-in procedure, the pre-etched glass-ceramic restorations may be contaminated with saliva resulting in reduced bond strength. This in-vitro study aimed to investigate the effect of different surface treatments on the bond strength of lithium disilicate (LD) glass-ceramic restorations (IPS e.max Press, Ivoclar Vivadent) to two resin cements. One-hundred eighty blocks (4X4X3mm) of LD glass-ceramic were divided into twelve groups (n = 15), of which six received Variolink Esthetic DC (VE) cement and six received RelyX Ultimate (RU) cement, following the surface treatments: G1) Control: Hydrofluoric Acid + Silane (HF + Sil); G2) Hydrofluoric Acid + Saliva + Silane (HF + S + Sil); G3) Hydrofluoric Acid + Saliva + Ivoclean + Silane (HF + S + IC + Sil); G4) Hydrofluoric Acid + Saliva + Phosphoric Acid + Silane (HF + S + P + Sil); G5) Hydrofluoric Acid + Saliva + Monobond Etch & Prime (HF + S + EP); G6) Monobond Etch & Prime (EP). Following treatment, a resin-cement cylinder (2.3 mm diameter) was built on the glass-ceramic surface, photocured (20 s), stored in distilled water (37 °C, 24 h) and submitted to the shear bond strength test. Bond strength data (MPa) were subjected to two-way ANOVA and Tukey (α = 0.01). Cement type and surface treatment had a significant effect on the bond strength (p < 0.001) (Table 4). Single-step Monobond Etch & Prime (EP) significantly improved the bond strength of resin-cements to glass-ceramic with and without saliva contamination.
Collapse
|
11
|
Tang T, Suputtamongkol K, Harnirattisai C, Neoh SP, Pongprueksa P. Interfacial fracture toughness of different surface treatments on zirconia-reinforced lithium silicate glass-ceramics. Dent Mater J 2023; 42:835-843. [PMID: 37880135 DOI: 10.4012/dmj.2023-124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
This study investigated the influence of different surface treatments on unfiring or firing zirconia-reinforced lithium silicate (ZLS) glass-ceramics. Celtra Duo and IPS e.max CAD blocks were cut and process following manufacturer protocols. The specimen surface was treated with seven different protocols. Two ceramic blocks with the same surface treatment were bonded with luting agent and prepared for mini-interfacial fracture toughness tests (mini-iFT). The specimens were tested after 1-week storage. The data was statistically analyzed using two-way ANOVA and Dunnett's T3 comparison (α=0.05). The highest mini-iFT of both Celtra Duo unfired and fired was shown in the HF+S group, which was not significantly different from HF+S+UA. For IPS e.max CAD, the mini-iFT was higher in the groups treated with hydrofluoric acid. Additional adhesive after silane application did not significantly improve bonding effectiveness. Therefore, surface treatment with hydrofluoric acid and silane is recommended for both unfiring and firing ZLS glass ceramics.
Collapse
|
12
|
Costa TNQ, Dotta TC, Galo R, Soares MEDC, Pedrazzi V. Effect of tribocorrosion on surface-treated titanium alloy implants: A systematic review with meta-analysis. J Mech Behav Biomed Mater 2023; 145:106008. [PMID: 37423010 DOI: 10.1016/j.jmbbm.2023.106008] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 06/30/2023] [Accepted: 07/03/2023] [Indexed: 07/11/2023]
Abstract
The purpose of this systematic review and meta-analysis was to compare the results of tribocorrosion in titanium alloys of dental implants submitted to surface treatment with those whose treatment was not performed. An electronic search was carried out on the MEDLINE (PubMed), Web of Science, Virtual Health Library and Scopus databases. The search strategy used was PECO: Participants (P): titanium alloys; Exposure (E): surface treatment; Comparison (C): absence of surface treatment; and Result/Outcome (O): tribocorrosion. The search found a total of 336 articles, where 27 was selected by title or abstract, resulted to 10 after reading in full. The treatments that formed the rutile layer had better tribological results and therefore better protected the material from mechanical and chemical degradation, contrary to the technique with the addition of nanotubes. It was concluded that the surface treatment proves to be efficient to protect metals from mechanical and chemical wear.
Collapse
|
13
|
Al-Johani H, Haider J, Silikas N, Satterthwaite J. Effect of surface treatments on optical, topographical and mechanical properties of CAD/CAM reinforced lithium silicate glass ceramics. Dent Mater 2023; 39:779-789. [PMID: 37438204 DOI: 10.1016/j.dental.2023.07.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/21/2023] [Accepted: 07/04/2023] [Indexed: 07/14/2023]
Abstract
OBJECTIVES To investigate the effect of different surface treatments on optical, topographical and mechanical properties of CAD/CAM lithium silicate-based glass ceramics (LSC's) and their combined effect on the output of a light curing unit (LCU). METHODS Four CAD/CAM LSC's were investigated: Lithium Disilicate (Emax CAD; EC), Zirconia-reinforced silicates (Vita Suprinity; VS and Celtra Duo;CD) and Lithium Aluminum Disilicate (CEREC Tessera; CT). Ceramic specimens (n = 240) were divided into six subgroups according to their surface treatment: (a) Control, (b) Hydrofluoric acid (HF) 5%, (c) HF 5% + Neutralizing agent (N), (d) HF 9%, (e) HF 9% +N and (f) Self-etching ceramic primer (SEP). Irradiance, power and radiant exposure of a LCU were measured with MARC-LC following ceramic specimen interposition. Direct light transmission (T%) and absorbance (Abs%) of the specimens were measured with UV-Vis spectrophotometry. Roughness (Sa, Sq) and wettability (θ°) were measured with optical profilometry and sessile drop profile analysis, respectively. Biaxial flexural strength (σ) of the ceramic specimens was measured by the ball-on-three-balls method and ceramic specimens were examined microscopically. Statistical analyses was performed by two-way ANOVA followed by post hoc multiple comparisons (α = 0.05). RESULTS Acid neutralization decreased T% and increased Abs% in all LSC's and highest T% was exhibited with VS. Neutralized EC, VS and CD displayed higher Sa in HF9, while neutralized CT displayed higher Sa in HF5. Self-etch primer significantly reduced θ° (p < 0.001). σ was observed in the followed ascending order: HF9 +N < HF9 < HF5 +N < HF5 < SEP < Control for all LSC's. SIGNIFICANCE Optical, topographical and mechanical properties of the CAD/CAM ceramic blocks were strongly dependent on the type of surface treatment. Results of neutralization post-etching indicate promising potential for future investigations.
Collapse
|
14
|
AlOtaibi AA, Taher NM. Effect of surface treatment on the repair bond strength of OMNICHROMA and Charisma Diamond ONE resin composites bonded to variable substrates. Heliyon 2023; 9:e17786. [PMID: 37455968 PMCID: PMC10339018 DOI: 10.1016/j.heliyon.2023.e17786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 06/08/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023] Open
Abstract
Objectives To compare repair bond strength of OMNICHROMA and Charisma Diamond ONE resin composites bonded to variable composite substrates. Also, to evaluate the influence of different surface treatments on repair bond strength. Methods A total of 80-disc shaped specimens was fabricated using two resin based composite materials; IPS Empress Direct Enamel and OptiShade (n = 40). Substrate discs were thermocycle 5000 cycles then each substrate material was subdivided based on the surface treatment into two groups; air particle abrasion (APA) and silicon carbide grinding (SiCr) both groups followed by phosphoric acid etching. All groups received a single bond universal adhesive application prior to repairing with composite, in a smaller disc shape. All specimens were thermocycled for 10,000 cycles prior to shear bond strength testing and subsequent failure analysis. Statistical analyses were conducted and the level of statistical significance was set at 0.05. Results The comparison of mean values (considering the combination of the two types of substrates, surface treatments and repairing materials) showed a highly statistically significant difference in the shear bond strength among the eight study groups (p < 0.0001). The highest value of mean shear bond strength was associated with OptiShade substrates repaired by Diamond ONE (38.6 ± 2.4). Meanwhile, the lowest value was recorded for the SiCr treated OptiShade group repaired by Diamond ONE (13.6 ± 2.3). The failure analysis revealed that cohesive mode of failure was the most predominant. Conclusion Omnichroma showed higher repair bond strength values with SiCr surface treatment. Meanwhile, Charisma Diamond ONE had better bond strength with APA. Surface pretreatment had a significant impact on the repair bond strength where APA groups had significantly higher values compared to SiCr groups. Clinical Significance: Within the limitation of the present study; APA is recommended as surface pretreatment for improved bond strength in restorative composite repairs.
Collapse
|
15
|
Sahoo N, Carvalho O, Özcan M, Silva F, Souza JCM, Lasagni AF, Henriques B. Ultrashort pulse laser patterning of zirconia (3Y-TZP) for enhanced adhesion to resin-matrix cements used in dentistry: An integrative review. J Mech Behav Biomed Mater 2023; 143:105943. [PMID: 37276650 DOI: 10.1016/j.jmbbm.2023.105943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 05/25/2023] [Accepted: 05/28/2023] [Indexed: 06/07/2023]
Abstract
Surface modification of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) using lasers for adhesion enhancement with resin-matrix cement has been increasingly explored. However, Y-TZP is chemically inert and non-reactive, demanding surface modification using alternative approaches to enhance its bond strength to resin-matrix cements. The main aim of this study was to conduct an integrative review on the influence of ultrashort pulse laser patterning of zirconia (3Y-TZP) for enhanced bonding to resin-matrix cements. An electronic search was performed on web of science, SCOPUS, Pubmed/Medline, Google Scholar and EMBASE using a combination of the following search items: zirconia, 3Y-TZP, surface modification, laser surface treatment, AND laser, ultrashortpulse laser, bonding, adhesion, and resin cement. Articles published in the English language, up to January 2022, were included regarding the influence of surface patterning on bond strength of Y-TZP to resin-matrix cements. Out of the 12 studies selected for the present review 10 studies assessed femtosecond lasers while 2 studies assessed picosecond lasers. Ultrashort pulsed laser surface patterning successfully produced different surface morphological aspects without damaging the bulk properties of zirconia. Contrarily, defects such as micro-cracks occurs after surface modification using traditional methods such as grit-blasting or long-pulsed laser patterning. Ultrashort pulsed laser surface patterning increase bond strength of zirconia to resin-matrix cements and therefore such alternative physical method should be considered in dentistry. Also, surface defects were avoided using ultrashort pulsed laser surface patterning, which become the major advantage when compared with traditional physical methods or long pulse laser patterning.
Collapse
|
16
|
Kang YJ, Kim H, Lee J, Park Y, Kim JH. Effect of airborne particle abrasion treatment of two types of 3D-printing resin materials for permanent restoration materials on flexural strength. Dent Mater 2023; 39:648-658. [PMID: 37210307 DOI: 10.1016/j.dental.2023.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 05/02/2023] [Accepted: 05/08/2023] [Indexed: 05/22/2023]
Abstract
OBJECTIVES This study aimed to assess the effects of airborne-particle abrasion (APA) on the flexural strength of two types of 3D-printing resins for permanent restoration. METHODS Two types of 3D printing resins (urethane dimethacrylate oligomer; UDMA, ethoxylated bisphenol-A dimethacrylate; BEMA) constituting different components were printed. The specimen surfaces were subjected to APA using 50 and 110 µm alumina particles under different pressures. The three-point flexural strength was measured for each surface treatment group, and a Weibull analysis was performed. Surface characteristics were analyzed via surface roughness measurements and scanning electron microscopy. Dynamic mechanical analysis and nano-indentation measurements were limited to the control group. RESULTS The three-point flexural strength according to the surface treatment was significantly lower in the UDMA group for large particle sizes and at high pressures; the BEMA group demonstrated low flexural strength for large particle sizes regardless of the pressure. After thermocycling, the flexural strengths of UDMA and BEMA significantly decreased in the group subjected to surface treatment. The Weibull modulus and characteristic strength of UDMA were higher than those of BEMA under different APA and thermocycling conditions. As the abrasion pressure and particle size increased, a porous surface formed, and the surface roughness increased. Compared with BEMA, UDMA featured a lower strain, greater strain recovery, and a negligible increase in modulus according to strain. SIGNIFICANCE Thus, surface roughness increased with the sandblasting particle size and pressure of the 3D-printing resin. Hence, a suitable surface treatment method to improve adhesion can be determined by considering physical property changes.
Collapse
|
17
|
Kolcu OB, Iren E, Yetkin T, Özok F, Erduran MN. Measurement of LYSO crystal light output and energy resolution improvement with acid etching. Appl Radiat Isot 2023; 199:110902. [PMID: 37379787 DOI: 10.1016/j.apradiso.2023.110902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 05/27/2023] [Accepted: 06/14/2023] [Indexed: 06/30/2023]
Abstract
In this study, we investigated the impact of chemical etching on the light output and energy resolution of LYSO scintillators using simple, affordable laboratory equipment. We found that etching with phosphoric acid at temperatures between 180 °C and 190 °C improved the light output and energy resolution compared to mechanically polished crystals, even after minimal etching times. Our results show that with 7.5 min of chemical etching, the light output increase rate is 45.7%, and the relative energy resolution improvement is 12%.
Collapse
|
18
|
Essam N, Soltan H, Attia A. Influence of thickness and surface conditioning on fracture resistance of occlusal veneer. BMC Oral Health 2023; 23:258. [PMID: 37138255 PMCID: PMC10157962 DOI: 10.1186/s12903-023-02932-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 04/03/2023] [Indexed: 05/05/2023] Open
Abstract
BACKGROUND The purpose of the current study was to assess the impact of restoration thickness, surface conditioning and the interaction between them on the fracture resistance of CAD/CAM fabricated lithium disilicate occlusal veneers. METHODS A total of 42 maxillary molars were prepared to receive CAD/CAM fabricated lithium disilicate occlusal veneer either with 0.5 mm (n = 21) or 1 mm (n = 21) thickness. Each main group was divided into 3 subgroups (n = 7), according to surface treatment, HF acid (HF-1, HF-0.5), acidulated phosphate fluoride (APF-1, APF-0.5) and Monobond etch & prime (MON-1, MON-0.5). Multilinik N (Ivoclar-Vivadent) adhesive resin cement was used for bonding according to the manufacturer instructions. One hour after bonding, specimens were stored in water bath for 75 days followed by cyclic loading fatigue for 240,000 cycles to simulate clinical situation. Finally, specimens were fractured under compressive load in (N) using a universal testing machine. Two and one-way ANOVA and Post Hoc Tukey test were used for statistical analysis. RESULTS The means ± SD (N) fracture load for each group were calculated. MON-1 group showed the highest fracture load (1644.7 ± 155.3) followed by HF-1 group (1514.6 ± 212.5). Meanwhile, APF-0.5 showed the lowest fracture load (962 ± 249.6). CONCLUSION CAD/CAM fabricated lithium disilicate occlusal veneers can be used with a thickness of 0.5 mm instead of conventional crowns. Monobond etch & prime is recommended as a surface treatment for CAD/CAM fabricated lithium disilicate occlusal veneer due to biological hazards of Hydrofluoric acid.
Collapse
|
19
|
Abd EL-wahab A, Shamaa M, Hafez A, El-Wassefy N, Hammad S. Shear bond strength of orthodontic brackets bonded to a new version of zirconium all ceramic restoration: An in vitro comparative study. Heliyon 2023; 9:e16249. [PMID: 37251835 PMCID: PMC10213195 DOI: 10.1016/j.heliyon.2023.e16249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 04/25/2023] [Accepted: 05/10/2023] [Indexed: 05/31/2023] Open
Abstract
Objectives Esthetic restorations such as monolithic zirconia crowns are highly requested for adults nowadays. Bonding orthodontic braces on this type of material became a challenge for orthodontists, because of the special surface treatment needed. This study aims to assess the shear bond strength (SBS) of metal, and ceramic brackets bonded on two types of zirconia ceramics, surface roughness (SR) after different surface treatments for their surfaces, and adhesive remnant index (ARI). Materials and methods Brackets' base surface area (BSA) was scanned by an extra-oral scanner, then measured. The doubled labial surface of monolithic zirconia crowns (n = 30) and monolithic high translucent zirconia crowns (n = 30) were prepared and each was divided into three groups (n = 10) depending on surface treatment (hydrofluoric acid etching, no treatment, and rocatec airborne abrasion). Extracted lower central incisors (n = 20) were prepared. Each of them was divided into two subgroups depending on the type of bracket bonded on their surfaces (metal and ceramic). The SR, SBS, and ARI were assessed. Statistical analysis used Tests used are independent-samples t-test, Fisher's exact test, One-Way ANOVA, and Kruskal-Wallis test. Results The highest SBS and SR were observed in Enamel/Metal and Zirconia/Metal/Rocatec subgroups, respectively. Conclusion Adequate bond strength could be obtained with the high translucent zirconia group if bonded with ceramic or metal brackets even if no treatment was used. Clinical significance A proportion of simulation was done like practicing inside the dental clinic to reach the best results regarding the adhesion strength of orthodontic brackets.
Collapse
|
20
|
Worpenberg C, Stiesch M, Eisenburger M, Breidenstein B, Busemann S, Greuling A. The effect of surface treatments on the adhesive bond in all-ceramic dental crowns using four-point bending and dynamic loading tests. J Mech Behav Biomed Mater 2023; 139:105686. [PMID: 36706651 DOI: 10.1016/j.jmbbm.2023.105686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 01/10/2023] [Accepted: 01/23/2023] [Indexed: 01/26/2023]
Abstract
The aim of this study was to determine the effect of sandblasting, grinding and plasma treatment on the adhesive bond strength between framework ceramic (Y-TZP) and veneering ceramic (feldspar ceramic). Therefore, four-point bending specimens (n = 180) were cut from densely sintered 3Y-TZP blanks. Subsequently, 80 of these samples received surface treatment by sandblasting and 80 samples by grinding. A reference group (20 samples) was not processed. Half of the specimens that received a surface treatment were additionally exposed to an oxygen plasma treatment. After processing, all specimens were manually veneered with feldspar ceramic and examined with a four-point bending test to evaluate the strain energy release rate G. The surface treatment parameters that achieved the highest and lowest G were transferred to real geometries of a posterior crown (n = 45). The crowns' ceramic framework was sandblasted and veneered by hand. The all-ceramic crowns were tested in a dynamic loading test and Wöhler curves were evaluated. Four-point bending samples blasted at an angle of 90° at 6 bar and a working distance of 1.5 cm without plasma treatment achieved the highest energy release rate. Samples blasted at an angle of 90° at 2 bar and a working distance of 1 cm with plasma treatment achieved the lowest energy release rate. Overall, plasma treatment did not improve bond strength. In the dynamic loading test, the group blasted with 2 bar showed the best results.
Collapse
|
21
|
Zhang S, Li S, Zhang H, Guo J, Gao X, Shi H, Liu F, Huang Z, Li S, Zhang Z. Integrating surface structure via triphenyl phosphate treatment to stabilize Li-rich Mn-based cathode materials. J Colloid Interface Sci 2023; 640:373-382. [PMID: 36867934 DOI: 10.1016/j.jcis.2023.02.054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 02/07/2023] [Accepted: 02/11/2023] [Indexed: 03/03/2023]
Abstract
Li-rich Mn-based layered oxides (LLOs) have emerged as one of the most promising cathode materials for the next-generation lithium-ion batteries (LIBs) because of their high energy density, high specific capacity, and environmental friendliness. These materials, however, have drawbacks such as capacity degradation, low initial coulombic efficiency (ICE), voltage decay, and poor rate performance due to irreversible oxygen release and structural deterioration during cycling. Herein, we present a facile method of triphenyl phosphate (TPP) surface treatment to create an integrated surface structure on LLOs that includes oxygen vacancies, Li3PO4, and carbon. When used for LIBs, the treated LLOs show an increased initial coulombic efficiency (ICE) of 83.6% and capacity retention of 84.2% at 1C after 200 cycles. It is suggested that the enhanced performance of the treated LLOs can be attributed to the synergetic functions of each component in the integrated surface, such as the oxygen vacancy and Li3PO4 being able to inhibit the evolution of oxygen and accelerate the transport of lithium ions, while the carbon layer can restrain undesirable interfacial side reactions and reduce the dissolution of transition metals. Furthermore, electrochemical impedance spectroscopy (EIS) and galvanostatic intermittent titration technique (GITT) prove an enhanced kinetic property of the treated LLOs cathode, and ex-situ X-ray diffractometer shows a suppressed structural transformation of TPP-treated LLOs during the battery reaction. This study provides an effective strategy for constructing an integrated surface structure on LLOs to achieve high-energy cathode materials in LIBs.
Collapse
|
22
|
Sahagian K. Gas Plasma Surface Modification for Biological Assays. Methods Mol Biol 2023; 2612:73-89. [PMID: 36795360 DOI: 10.1007/978-1-0716-2903-1_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
Surface chemistry plays an important role in the adsorption and immobilization of enzymes and antibodies. Gas plasma technology performs surface preparation that assists in the attachment of molecules. Surface chemistry helps to manage a material's wetting, joining, or the reproducibility of surface interactions. There are numerous examples of commerically available products that utilize gas plasma in their manufacturing process. Examples of products treated by gas plasma are well plates, microfluidic devices, membranes, fluid dispensers, and some medical devices. This chapter presents an overview of gas plasma technology and provides a guide for using gas plasma for designing surfaces in product development or research.
Collapse
|
23
|
[Research on friction and wear behaviors of silicon-lithium spray coating on zirconia ceramics]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2023; 55:94-100. [PMID: 36718695 PMCID: PMC9894791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE To study microstructure, friction and wear behaviors of silicon-lithium spray coating on the surface of zirconia ceramics and to preliminarily evaluate its esthetic so as to provide support and guidance for the clinical application. METHODS Zirconia ceramic specimens were randomly divided into three groups: coating group (two subgroups), polishing group (two subgroups), and glazing group (four subgroups), with 10 samples in each subgroup. The two subgroups of coating group were the zirconia ceramics with the untreated and preliminary polishing surfaces sprayed with silicon-lithium coating, respectively. The two subgroups of polishing group were preliminary polishing and fine polishing of zirconia ceramics, respectively. The four subgroups of glazing group were preliminarily polished zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively; and untreated zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively. The above 8 subgroups of zirconia ceramic specimens were used as friction pairs with 80 steatite ceramics for 50 000 chewing cycles under 50 N vertical load and artificial saliva lubrication using chewing simulation. Scanning electron microscope was used to observe the microstructure of the surface and section of the coating group, and the thickness of the coating and glazing were measured. The linear roughness of the coating and polishing groups was mea-sured using a laser confocal scanning microscope. Vickers hardness was measured using a microhardness tester and the esthetic of zirconia ceramic full crown sprayed with silicon-lithium coating was preliminarily evaluated. White light interferometer was used to measure the width, the maximum depth and the volume of the wear scars of each group, and the wear depth of steatite ceramics and wear rate of zirconia ceramic specimens were calculated. Kruskal-Wallis nonparametric test and Dunn's multiple comparisons test were used to analyze the wear depth of each group (α=0.05). RESULTS The microstructures of the silica-lithium spray coatings on the untreated and preliminarily polished zirconia ceramic surfaces showed the protruding defects, and the line roughness of coating group was larger than that of the polishing group. The median thickness of the silica-lithium spray coating on the preliminarily polished zirconia ceramic was 13.0 μm (interquartile range, IQR: 11.6, 17.9), while that of the silica-lithium spray coating on the untreated zirconia ceramic was 4.4 μm (IQR: 4.1, 4.7). The Vickers hardness and wear rate of the coating group were between the polishing group and the glazing group. The wear depths of the wear scars of steatite ceramics were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference between glazing and polishing groups (P < 0.05). With the increase of polishing procedure, the wear depth of steatite ceramics decreased in each subgroups. The orders of maximum depth and volume of wear scars of zirconia ceramic were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference in the maximum depth of wear scars between glazing and polishing groups (P < 0.05). CONCLUSION The silica-lithium spray coating on the zirconia ceramic, can be used as a new method for zirconia ceramic surface treatment, because it can increase the esthetic of zirconia ceramics compared with polishing and reduce the wear of steatite ceramics compared with glazing.
Collapse
|
24
|
Hemmati YB, Asli HN, Nahavandi AM, Safari N, Falahchai M. Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling. Korean J Orthod 2023; 53:139-149. [PMID: 36760218 DOI: 10.4041/kjod22.144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 11/18/2022] [Accepted: 11/27/2022] [Indexed: 02/11/2023] Open
Abstract
Objective To assess the color stability and translucency of full cubic stabilized zirconia (FSZ) following orthodontic bonding with different surface treatments and coffee thermocycling (CTC). Methods This in vitro study was conducted on 120 disc-shaped specimens of FSZ. Thirty specimens were selected as the control group and remained intact. The remaining specimens were randomly divided into three groups based on the type of surface treatment (n = 30): airborne particle abrasion (APA), silica-coating (CoJet), and carbon dioxide (CO2) laser. After metal bracket bonding in the test groups, debonding and polishing were performed. Subsequently, all specimens underwent CTC (10,000 cycles). Color parameters, color difference (ΔE00), and translucency parameter (TP) were measured three times at baseline (t0), after debonding and polishing (t1), and after CTC (t2). Data were statistically analyzed (α = 0.05). Results Significant difference existed among the groups regarding ΔE00t0t2 (p < 0.001). The APA group showed minimum (ΔE00 = 1.15 ± 0.53) and the control group showed maximum (ΔE00 = 0.19 ± 0.02) color stability, with no significant difference between the laser and CoJet groups (p = 0.511). The four groups were significantly different regarding ∆TPt0t2 (p < 0.001). Maximal increases in TP were noted in the CoJet (1.00 ± 0.18) and APA (1.04 ± 0.38) groups while minimal increase was recorded in the control group (0.1 ± 0.02). Conclusions Orthodontic treatment makes zirconia restorations susceptible to discoloration and increased translucency. Nonetheless, the recorded ΔE00 and ∆TP did not exceed the acceptability threshold.
Collapse
|
25
|
Simões IG, Kreve S, Cruz MAE, Botelho AL, Ramos AP, Dos Reis AC, Valente MLDC. Influence of Er:YAG laser irradiation on surface properties of Ti-6Al-4V machined and hydroxyapatite coated. Lasers Med Sci 2023; 38:48. [PMID: 36689006 DOI: 10.1007/s10103-023-03719-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 01/17/2023] [Indexed: 01/24/2023]
Abstract
Surface treatment by laser irradiation can change the topography of titanium; however, little is known about the changes it causes when applied to other coatings. This study aimed to evaluate the influence of Er:YAG laser irradiation on the surface properties of titanium-aluminum-vanadium (Ti-6Al-4V) discs. Four Ti-6Al-4V surfaces were evaluated (n = 10): CON-control, machined without surface treatment; LT-machined + laser treatment; HA-hydroxyapatite coating; and LT-HA-hydroxyapatite coating + laser treatment. For the laser treatment, an Er:YAG laser with a wavelength of 2940 nm, a frequency of 10 Hz, and an energy density of 12.8 J/cm2 was used. The morphology of the coating was investigated by scanning electron microscopy and the surface composition by energy-dispersive X-ray spectroscopy. The influence of laser irradiation treatment on roughness and wettability was also evaluated. The Er:YAG laser promoted a significant reduction in the roughness Sa (p < 0.05) and in the contact angle (p = 0.002) of the LT surface compared to the CON surface. On the LT-HA surface, a significant decrease in roughness was observed only for the Rz parameter (p = 0.015) and an increase in the contact angle (p < 0.001) compared to the HA surface. The use of the Er:YAG laser with the evaluated parameters decreased the surface roughness and improved the wetting capacity of machined without surface treatment. In the group with hydroxyapatite coating, the laser influenced the surface roughness only for the parameter Rz and reduced their wetting capacity.
Collapse
|