1
|
Palić B, Goluža Sesar M, Galić K, Bogdan G, Prskalo Z. A Double Rarity: Lost intravascular Catheter Guidewire in Persistent Left Superior Vena Cava and Coronary Sinus - A Case Report. Vasc Health Risk Manag 2024; 20:245-250. [PMID: 38859874 PMCID: PMC11164207 DOI: 10.2147/vhrm.s453977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Accepted: 05/28/2024] [Indexed: 06/12/2024] Open
Abstract
Guidewire loss is a rare complication of central venous catheterization. A 65-year-old male was hospitalized in a high-dependency unit for exacerbation of chronic obstructive pulmonary disease, pneumonia, erythrocytosis, and clinical signs of heart failure. Upon admission, after an unsuccessful right jugular approach, a left jugular central venous catheter was placed. The next day, chest radiography revealed the catheter located in the left parasternal region, with suspected retention of the guidewire, visually confirmed by the presence of its proximal end inside the catheter. The left parasternal location of the catheter and the typical projection of the guidewire in the coronary sinus, later confirmed by echocardiography, raised suspicion of a persistent left superior vena cava (PLSVC). Agitated saline injected into the left antecubital vein confirmed bubble entry from the coronary sinus into the right atrium. After clamping the guidewire, the catheter was carefully retrieved along with the guidewire without any complications. This is the first reported case of guidewire retention in PLSVC and coronary sinus. It underscores the potential causes of guidewire loss and advocates preventive measures to avoid this potentially fatal complication.
Collapse
|
2
|
Nakamoto M, Omuro A, Uchinoumi H, Wada Y, Tanaka N, Yano M. Diagnosis of a coronary artery fistula connected to the coronary sinus with transthoracic echocardiography: a case report. J Echocardiogr 2024; 22:108-109. [PMID: 37486525 DOI: 10.1007/s12574-023-00616-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 06/12/2023] [Accepted: 07/04/2023] [Indexed: 07/25/2023]
|
3
|
Huynh K. The coronary sinus reducer improves angina symptoms in patients with stable CAD. Nat Rev Cardiol 2024; 21:356. [PMID: 38664573 DOI: 10.1038/s41569-024-01033-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
|
4
|
Asfaw EK, Agarwal PP, Lee EM. NASCI case of the month: "Unroofed coronary sinus without persistent left-sided superior vena cava". THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2024; 40:1159-1160. [PMID: 38703291 DOI: 10.1007/s10554-024-03108-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 04/04/2024] [Indexed: 05/06/2024]
Abstract
Unroofed sinus is categorized into four subtypes. Types I and II represent complete unroofing with or without an LSVC, respectively [1]. Types III and IV are partial unroofing involving the mid-CS (type III) or near the LA appendage and left superior pulmonary vein (type IV) [1]. CT has advantages over echocardiography in detection of this anomaly (illustrated in this case) as well as in precise delineation of defect and associated findings (presence or absence of LSVC). Short axis reconstructions at the level of CS are helpful in diagnosis. Considerations for repair include location of CS defect, presence of LSVC and other abnormalities as well as comorbidity risks [2].
Collapse
|
5
|
Foley MJ, Rajkumar CA, Ahmed-Jushuf F, Simader FA, Chotai S, Pathimagaraj RH, Mohsin M, Salih A, Wang D, Dixit P, Davies JR, Keeble TR, Cosgrove C, Spratt JC, O'Kane PD, De Silva R, Hill JM, Nijjer SS, Sen S, Petraco R, Mikhail GW, Khamis R, Kotecha T, Harrell FE, Kellman P, Francis DP, Howard JP, Cole GD, Shun-Shin MJ, Al-Lamee RK. Coronary sinus reducer for the treatment of refractory angina (ORBITA-COSMIC): a randomised, placebo-controlled trial. Lancet 2024; 403:1543-1553. [PMID: 38604209 DOI: 10.1016/s0140-6736(24)00256-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/04/2024] [Accepted: 02/07/2024] [Indexed: 04/13/2024]
Abstract
BACKGROUND The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.
Collapse
|
6
|
Shin SB, Park WK, Choi JW, Jung JP, Park CR, Lee YJ, Kim GS. Surgical management of multiple coronary artery to coronary sinus fistulas with giant left circumflex artery and multivalvular infective endocarditis. J Cardiothorac Surg 2024; 19:186. [PMID: 38582866 PMCID: PMC10998348 DOI: 10.1186/s13019-024-02657-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 03/19/2024] [Indexed: 04/08/2024] Open
Abstract
Coronary artery fistula (CAF) is characterized as a congenital or acquired abnormal communication between a coronary artery and any of the four chambers of the heart (coronary-cameral fistula) or great vessels (coronary arteriovenous fistula) bypassing the capillaries within myocardium. CAF is a rare disease, challenging to diagnose and treat depending on the anatomical location and type of the fistula and accompanying diseases. This study aims to report a case with multiple coronary artery to coronary sinus (CS) fistulas with giant left circumflex artery and multivalvular infective endocarditis.
Collapse
|
7
|
Smolarek D, Jankowska H, Dorniak K, Hellmann M. A rare case of isolated persistent left superior vena cava diagnosed by echocardiography. J Cardiothorac Surg 2024; 19:175. [PMID: 38575998 PMCID: PMC10996098 DOI: 10.1186/s13019-024-02709-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 03/29/2024] [Indexed: 04/06/2024] Open
Abstract
BACKGROUND The persistent left superior vena cava (PLSVC) is an infrequent vascular variant. PLSVC with absent right superior vena cava, also known as isolated PLSVC, is an exceptionally rare entity. In this case we present a patient with isolated PLSVC draining to coronary sinus, diagnosed incidentally during echocardiography. CASE PRESENTATION A 35-year-old man underwent a transthoracic echocardiography which showed an enormously dilated coronary sinus. Hand-agitated saline was injected via peripheral intravenous cannulas. The contrast appeared firstly in the coronary sinus before it opacified the right atrium. Since this was also visible by the right antecubital saline injection, it indicated an extremely rare case of PLSVC with the absence of right superior vena cava which was confirmed by cardiac magnetic resonance. CONCLUSIONS The finding of a distinctively dilated coronary sinus in echocardiography led us to further investigation using agitated saline that revealed an infrequent anomaly termed isolated PLSVC. The in-depth diagnosis of this vascular variant is crucial considering that it may lead to important clinical implications, such as difficulties with central venous access, especially in the current era of a rapid development of cardiac device therapies.
Collapse
|
8
|
Boban M, Zulj M. Editorial for "Myocardial Blood Flow Determination from Contrast-Free Magnetic Resonance Imaging Quantification of Coronary Sinus Flow". J Magn Reson Imaging 2024; 59:1267-1268. [PMID: 37675954 DOI: 10.1002/jmri.29005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 05/27/2023] [Indexed: 09/08/2023] Open
|
9
|
Mestrovic IP, Breskovic T, Markovic M, Kurtic E, Mestrovic T, Anic A. Ablation of epicardial ventricular focus through coronary sinus using pulsed-field ablation. A case report. J Cardiovasc Electrophysiol 2024; 35:856-861. [PMID: 38297424 DOI: 10.1111/jce.16195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 01/08/2024] [Accepted: 01/16/2024] [Indexed: 02/02/2024]
Abstract
INTRODUCTION With the entry of pulsed-field ablation (PFA) into electrophysiology, new possibilities for ablation of different substrates such as epicardial foci of premature ventricular contractions (PVCs) from coronary venous system (CVS) have been opened. METHODS This article focuses on a case of a 27-year-old patient with frequent monomorphic PVCs of epicardial origin, treated by radiofrequency ablation, followed by PFA. RESULTS After unsuccessful focus ablation through CVS with RFA, successful ablations from the same region with PFA were achieved. CONCLUSION This is the first described case of successful ablation of epicardial PVCs using PFA, which we hope will help in defining indications for this novel technology and enhance quality of treatment for patients with different arrhythmias.
Collapse
|
10
|
De Maria GL, Greenwood JP, Zaman AG, Carrié D, Coste P, Valgimigli M, Behan M, Berry C, Erglis A, Panoulas VF, Van Belle E, Juhl Terkelsen C, Hunziker Munsch L, Jain AK, Lassen JF, Palmer N, Stone GW, Banning AP. Pressure-Controlled Intermittent Coronary Sinus Occlusion (PiCSO) in Acute Myocardial Infarction: The PiCSO-AMI-I Trial. Circ Cardiovasc Interv 2024; 17:e013675. [PMID: 38626079 DOI: 10.1161/circinterventions.123.013675] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 01/09/2024] [Indexed: 04/18/2024]
Abstract
BACKGROUND Primary percutaneous coronary intervention (pPCI) has improved clinical outcomes in patients with ST-segment-elevation myocardial infarction. However, as many as 50% of patients still have suboptimal myocardial reperfusion and experience extensive myocardial necrosis. The PiCSO-AMI-I trial (Pressure-Controlled Intermittent Coronary Sinus Occlusion-Acute Myocardial Infarction-I) evaluated whether PiCSO therapy can further reduce myocardial infarct size (IS) in patients undergoing pPCI. METHODS Patients with anterior ST-segment-elevation myocardial infarction and Thrombolysis in Myocardial Infarction flow 0-1 were randomized at 16 European centers to PiCSO-assisted pPCI or conventional pPCI. The PiCSO Impulse Catheter (8Fr balloon-tipped catheter) was inserted via femoral venous access after antegrade flow restoration of the culprit vessel and before proceeding with stenting. The primary end point was the difference in IS (expressed as a percentage of left ventricular mass) at 5 days by cardiac magnetic resonance. Secondary end points were the extent of microvascular obstruction and intramyocardial hemorrhage at 5 days and IS at 6 months. RESULTS Among 145 randomized patients, 72 received PiCSO-assisted pPCI and 73 conventional pPCI. No differences were observed in IS at 5 days (27.2%±12.4% versus 28.3%±11.45%; P=0.59) and 6 months (19.2%±10.1% versus 18.8%±7.7%; P=0.83), nor were differences between PiCSO-treated and control patients noted in terms of the occurrence of microvascular obstruction (67.2% versus 64.6%; P=0.85) or intramyocardial hemorrhage (55.7% versus 60%; P=0.72). The study was prematurely discontinued by the sponsor with no further clinical follow-up beyond 6 months. However, up to 6 months of PiCSO use appeared safe with no device-related adverse events. CONCLUSIONS In this prematurely discontinued randomized trial, PiCSO therapy as an adjunct to pPCI did not reduce IS when compared with conventional pPCI in patients with anterior ST-segment-elevation myocardial infarction. PiCSO use was associated with increased procedural time and contrast but no increase in adverse events up to 6 months. REGISTRATION URL: https://www.clinicaltrials.gov; Unique identifier: NCT03625869.
Collapse
|
11
|
Tingsgaard JK, Sørensen MH, Bojer AS, Anderson RH, Broadbent DA, Plein S, Gaede P, Madsen PL. Myocardial Blood Flow Determination From Contrast-Free Magnetic Resonance Imaging Quantification of Coronary Sinus Flow. J Magn Reson Imaging 2024; 59:1258-1266. [PMID: 37491887 DOI: 10.1002/jmri.28919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 07/09/2023] [Accepted: 07/10/2023] [Indexed: 07/27/2023] Open
Abstract
BACKGROUND Determination of myocardial blood flow (MBF) with MRI is usually performed with dynamic contrast enhanced imaging (MBFDCE ). MBF can also be determined from coronary sinus blood flow (MBFCS ), which has the advantage of being a noncontrast technique. However, comparative studies of MBFDCE and MBFCS in large cohorts are lacking. PURPOSE To compare MBFCS and MBFDCE in a large cohort. STUDY TYPE Prospective, sequence-comparison study. POPULATION 147 patients with type 2 diabetes mellitus (age: 56+/-12 years; 106 male; diabetes duration: 12.9+/-8.1 years), and 25 age-matched controls. FIELD STRENGTH/SEQUENCES 1.5 Tesla scanner. Saturation recovery sequence for MBFDCE vs. phase-contrast gradient-echo pulse sequence (free-breathing) for MBFCS . ASSESSMENT MBFDCE and MBFCS were determined at rest and during coronary dilatation achieved by administration of adenosine at 140 μg/kg/min. Myocardial perfusion reserve (MPR) was calculated as the stress/rest ratio of MBF values. Coronary sinus flow was determined twice in the same imaging session for repeatability assessment. STATISTICAL TESTS Agreement between MBFDCE and MBFCS was assessed with Bland and Altman's technique. Repeatability was determined from single-rater random intraclass and repeatability coefficients. RESULTS Rest and stress flows, including both MBFDCE and MBFCS values, ranged from 33 to 146 mL/min/100 g and 92 to 501 mL/min/100 g, respectively. Intraclass and repeatability coefficients for MBFCS were 0.95 (CI 0.90; 0.95) and 5 mL/min/100 g. In Bland-Altman analysis, mean bias at rest was -1.1 mL/min/100 g (CI -3.1; 0.9) with limits of agreement of -27 and 24.8 mL/min/100 g. Mean bias at stress was 6.3 mL/min/100 g (CI -1.1; 14.1) with limits of agreement of -86.9 and 99.9. Mean bias of MPR was 0.11 (CI: -0.02; 0.23) with limits of agreement of -1.43 and 1.64. CONCLUSION MBF may be determined from coronary sinus blood flow, with acceptable bias, but relatively large limits of agreement, against the reference of MBFDCE . LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY STAGE: 2.
Collapse
|
12
|
Traverse JH. Use of Pressure-Controlled Intermittent Coronary Sinus Occlusion in STEMI: The Road Not Taken! Circ Cardiovasc Interv 2024; 17:e014078. [PMID: 38626082 DOI: 10.1161/circinterventions.124.014078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/18/2024]
|
13
|
Deniz Ç, Canpolat U. Incidental Detection of Coronary Sinus Agenesis in Two Patients with Surgically Repaired Atrial Septal Defect. Turk Kardiyol Dern Ars 2024; 52:220-221. [PMID: 38573096 DOI: 10.5543/tkda.2023.80348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2024] Open
|
14
|
Nagpal R, Lalani K, Ramachandran P. Giant coronary sinus aneurysm: an incidental discovery in a case of acute coronary syndrome. BMJ Case Rep 2024; 17:e258727. [PMID: 38479829 PMCID: PMC10941150 DOI: 10.1136/bcr-2023-258727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2024] Open
Abstract
Coronary sinus (CS) anomalies, although infrequent, are increasingly diagnosed with advances in interventional procedures and imaging techniques. Most cases are asymptomatic and incidentally diagnosed. We present a case of an elderly male without comorbidities who presented with acute angina. Coronary catheterisation revealed a double-vessel disease, but incidentally, sequential angiograms captured contrast filling in the levophase of CS, revealing a giant CS. Primary percutaneous angioplasty of the right coronary artery was performed successfully. Echocardiography confirmed the aneurysm, and a CT scan showed an aneurysmally dilated CS and other coronary veins alongside a normal-sized persistent left superior vena cava draining to the right atrium through CS. CS aneurysms may lead to complications such as thrombosis, embolic events, arrhythmias and heart failure, stressing the importance of vigilant monitoring and timely intervention. This case underscores the significance of recognising CS anomalies in cardiac procedures, even when asymptomatic, for proper management.
Collapse
|
15
|
Huang C, Deng L. Left Coronary Artery-to-Right Coronary Sinus Fistula. Radiology 2024; 310:e233027. [PMID: 38470233 DOI: 10.1148/radiol.233027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
|
16
|
Bober RM, Johnson NP. How might coronary sinus reducer treatment change myocardial perfusion? J Nucl Cardiol 2024; 33:101828. [PMID: 38395338 DOI: 10.1016/j.nuclcard.2024.101828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Accepted: 02/16/2024] [Indexed: 02/25/2024]
|
17
|
Lai B, Yang Q, Deng M. Coronary artery fistula with giant right coronary artery aneurysm and right coronary sinus tumor. Asian J Surg 2024; 47:1592-1593. [PMID: 38097496 DOI: 10.1016/j.asjsur.2023.12.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 12/01/2023] [Indexed: 03/13/2024] Open
|
18
|
Cheng K, Tan ST, Wechalekar K, Keramida G, de Silva R. Redistribution of myocardial perfusion after coronary sinus reducer implantation demonstrated by rubidium-82 positron emission tomography. J Nucl Cardiol 2024; 33:101803. [PMID: 38219971 DOI: 10.1016/j.nuclcard.2024.101803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 12/31/2023] [Accepted: 01/08/2024] [Indexed: 01/16/2024]
|
19
|
Canitrot R, Carrié D, Lhermusier T, Servoz C. Snare technique failure in extracting an embolized coronary sinus reducer to the pulmonary artery. THE JOURNAL OF INVASIVE CARDIOLOGY 2024; 36. [PMID: 38441993 DOI: 10.25270/jic/23.00230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
We report the case of a 79-year-old male patient who benefited from the implantation of a coronary sinus reducer (CSR) (Reducer; Neovasc, Inc.) in the management of typical angina with mild exertion with optimal medical treatment.
Collapse
|
20
|
Subramanian P, Naganur SH, Sharma A, Singhal M. Unilateral Anomalous Pulmonary Venous Return into Coronary Sinus. Radiol Cardiothorac Imaging 2024; 6:e230359. [PMID: 38329406 PMCID: PMC10912887 DOI: 10.1148/ryct.230359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 01/09/2024] [Accepted: 01/11/2024] [Indexed: 02/09/2024]
|
21
|
Ford TJ, Redwood E, Chuah E. Coronary Sinus Reduction: Can Device-Based Therapy Improve Coronary Microvascular Function? Circ Cardiovasc Interv 2024; 17:e013831. [PMID: 38227698 DOI: 10.1161/circinterventions.123.013831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2024]
|
22
|
Yuge N, Manabe S, Hirayama D, Yamada R, Hori M, Saito T, Mochizuki N, Sugimura K, Shimokawa H. A Surgical Case of Partially Unroofed Coronary Sinus Atrial Septal Defect in an Elderly Patient Diagnosed by Preoperative Contrast-Enhanced Computed Tomography. Int Heart J 2024; 65:155-158. [PMID: 38296570 DOI: 10.1536/ihj.23-401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.
Collapse
|
23
|
Chen M, Wu Z, Hu L, Li X, Yang H, Liu Z, Xiao Y, Liu Q, Zhou S. The effectiveness and safety of temporary transvenous cardiac pacing leads placement into coronary sinus vein in patients with sick sinus syndrome. Ann Noninvasive Electrocardiol 2024; 29:e13099. [PMID: 37997537 PMCID: PMC10770809 DOI: 10.1111/anec.13099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 09/04/2023] [Accepted: 10/30/2023] [Indexed: 11/25/2023] Open
Abstract
BACKGROUND The temporary pacing lead routinely is placed into right ventricular (RV), which pose a risk of dislocation and cardiac perforation. OBJECTIVE We aim to evaluate the effectiveness and safety of temporary transvenous cardiac pacing (TTCP) leads placement into the coronary sinus vein (CSV) in patients with sick sinus syndrome (SSS). METHODS We investigated patients with SSS who underwent TTCP lead placement into the CSV under the guidance of X-ray between January 2013 and May 2023. Patients were randomly divided into two groups: RV group (n = 33) and CSV group (n = 22). The ordinary passive bipolar electrodes were applied in both groups. In RV groups, electrodes were placed into RV. In CSV group, electrodes were placed into CSV. We evaluated the operation duration, fluoroscopic exposure, first-attempt success rate of leads placement, pacing threshold, success rate of leads placement, rate of leads displacement, and complications. RESULTS Compared with that in RV group, the procedure time, fluoroscopic exposure was significantly prolonged, while the first-attempt success rate of lead placement was obviously increased in CSV group (both p < .05). Compared with that in RV group, the rate of leads displacement is lower in CSV group (both p < .05). There were three patients occurred cardiac perforation in RV group, but no cardiac perforation was reported in CSV group (p > .05). CONCLUSION TTCP leads placement into the CSV is an effective and safe strategy in patients with SSS. It indicates a high rate of pacing effectiveness with low device replacement and complication rates.
Collapse
|
24
|
Tebaldi M, Campo G, Ugo F, Guarracini S, Marrone A, Clò S, Abdirashid M, Di Mauro M, Rametta F, Di Marco M, Cocco M, Marchini F, Penzo C, Erriquez A, Banai S, Biscaglia S. Coronary Sinus Narrowing Improves Coronary Microcirculation Function in Patients With Refractory Angina: A Multicenter Prospective INROAD Study. Circ Cardiovasc Interv 2024; 17:e013481. [PMID: 38227697 DOI: 10.1161/circinterventions.123.013481] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/10/2023] [Indexed: 01/18/2024]
Abstract
BACKGROUND The underlying mechanisms responsible for the clinical benefits following coronary sinus narrowing and pressure elevation remain unclear. The present study aims to investigate whether coronary sinus narrowing improves the indexes of coronary microcirculatory function. METHODS Patients with refractory angina who had a clinical indication for reducer implantation underwent invasive physiological assessments before and 4 months after the procedure. The primary outcome was the change in the values of the index of microcirculatory resistance. Secondary end points included changes in coronary flow reserve and the resistive resistance ratio values. Angina status was assessed with the Canadian Cardiology Society class and the Seattle Angina Questionnaire. RESULTS Twenty-four patients with a history of obstructive coronary artery disease and prior coronary revascularization (surgical and percutaneous) treated with reducer implantation were enrolled, and 21 of them (87%) underwent repeated invasive coronary physiological assessment after 4 months. The index of microcirculatory resistance values decreased from 33.35±19.88 at baseline to 15.42±11.36 at 4-month follow-up (P<0.001; mean difference, -17.90 [95% CI, -26.16 to -9.64]). A significant (≥20% from baseline) reduction of the index of microcirculatory resistance was observed in 15 (71.4% [95% CI, 47.8%-88.7%]) patients. The number of patients with abnormal index of microcirculatory resistance (≥25) decreased from 12 (57%) to 4 (19%; P=0.016). Coronary flow reserve increased from 2.46±1.52 to 4.20±2.52 (mean difference, 1.73 [95% CI, 0.51-2.96]). Similar findings were observed for resistive resistance ratio values. Overall, 16 patients (76.1%) had an improvement of 1 Canadian Cardiology Society class. Seattle Angina Questionnaire summary score increase of around 3 points (3.01 [95% CI, 1.39-4.61]). CONCLUSIONS Coronary sinus reduction implantation is associated with a significant improvement in the parameters of coronary microcirculatory function. These findings provide insights into the improvement of angina symptoms and may have implications for the treatment of coronary microvascular dysfunction. REGISTRATION URL: https://www.clinicaltrials.gov; Unique identifier: NCT05174572.
Collapse
|
25
|
Zhang S, Wu Z, Chen M, Li X, Liu Q, Zhou S. Comparison between conventional approach and three-dimensional mapping system in the catheter ablation of accessory pathway associated with coronary sinus diverticulum: A single-center experience. Ann Noninvasive Electrocardiol 2024; 29:e13100. [PMID: 38115789 PMCID: PMC10770808 DOI: 10.1111/anec.13100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 10/28/2023] [Accepted: 11/15/2023] [Indexed: 12/21/2023] Open
Abstract
BACKGROUND Posteroseptal accessory pathways (APs) associated with coronary sinus (CS) diverticulum present a rare and challenge for ablation. This study aimed to compare the safety and efficacy of conventional approach and three-dimensional (3D) mapping system in the catheter ablation. METHODS AND RESULTS This was a retrospective study of all patients (from January 2013 to July 2022) who underwent catheter ablation of posteroseptal AP associated with CS diverticula in our center. Patients who underwent catheter ablation using the traditional fluoroscopy method were included in the conventional method group (n = 13). Patients who underwent catheter ablation using the 3D mapping method were included in the 3D mapping group (n = 11). Clinical characteristics, ablation procedure, and outcomes were recorded and analyzed between the two groups. Out of 669 patients with posteroseptal APs, 24 of them (3.6%) were associated with CS diverticula. All patients in both groups successfully completed the electrophysiological study. In the conventional method group, two patients experienced complications (one patient with pericardial effusion and the other patient with femoral arterial hematoma), and two patients had recurrence. However, no patients suffered from complications or recurrence during follow-up. The procedure time and fluoroscopy time in the conventional method group were significantly longer than those in the 3D mapping method group. CONCLUSIONS The utilization of 3D mapping led to reduced fluoroscopy time, shorter procedure duration, enhanced acute success rates, and decreased incidence of complications.
Collapse
|