1
|
Bacharach J, Brubaker JW, Evans DG, Lu F, Odani-Kawabata N, Yamabe T, Wirta DL. Omidenepag Isopropyl Versus Timolol in Patients With Glaucoma or Ocular Hypertension: Two Randomized Phase 3 Trials (SPECTRUM 4 and 3). Am J Ophthalmol 2024; 263:23-34. [PMID: 38395329 DOI: 10.1016/j.ajo.2024.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 02/05/2024] [Accepted: 02/06/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE The SPECTRUM 4 and 3 studies assessed the intraocular pressure (IOP)-lowering efficacy and safety of omidenepag isopropyl (OMDI) 0.002% vs timolol 0.5% in patients with glaucoma or ocular hypertension (OHT). DESIGN Phase 3, randomized, controlled, double-masked, noninferiority studies. METHODS Multicenter studies in the US. Inclusion criteria for adults ≥ 18 years (SPECTRUM 4 [N = 409] and 3 [N = 413]) were open-angle glaucoma or OHT, and IOP ≥ 22 mm Hg and ≤ 34 mm Hg; and for pediatric patients < 18 years (N = 13, SPECTRUM 3) were pediatric glaucoma or OHT. The primary objective in both studies was OMDI noninferiority to timolol in reducing IOP (3 months). SPECTRUM 3 included an additional 9 months of OMDI treatment. Safety evaluations were of ocular/non-ocular adverse events (AEs). RESULTS The IOP-lowering range of OMDI remained consistent in SPECTRUM 4 and 3 (-5.6 to -5.9 vs -5.3 to -5.7 mm Hg, respectively); however, timolol efficacy varied (-5.4 to -6.1 vs -6.4 to -7.0 mm Hg, respectively). OMDI noninferiority was achieved in SPECTRUM 4. Efficacy was maintained with 12-month treatment in SPECTRUM 3. Both studies reported more ocular AEs with OMDI, but lower rates of appearance-altering AEs vs timolol. No new safety concerns were identified. Rates of macular edema in pseudophakic patients increased with prolonged OMDI exposure. CONCLUSIONS SPECTRUM 4 and 3 demonstrated consistent 3-month IOP-lowering efficacy and safety of OMDI vs timolol in patients with glaucoma or OHT. The 12-month data from SPECTRUM 3 suggest OMDI may have long-term benefits in patients with glaucoma or OHT.
Collapse
|
2
|
Chirapapaisan C, Eiamsamarng A, Chirapapaisan N, Raksong W, Sakiyalak D, Koodkaew S, Subunnasenee A. Effects of intraocular pressure change on intraocular lens power calculation in primary open-angle glaucoma and ocular hypertension. PLoS One 2024; 19:e0304169. [PMID: 38857282 PMCID: PMC11164340 DOI: 10.1371/journal.pone.0304169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 05/08/2024] [Indexed: 06/12/2024] Open
Abstract
This study aimed to assess the effect of intraocular pressure (IOP) changes on biometry and intraocular lens (IOL) power calculation in patients diagnosed with primary open-angle glaucoma (POAG) and ocular hypertension (OHT). This prospective non-randomized cohort study enrolled patients with diagnosed POAG and OHT, presenting with IOP levels exceeding 25 mmHg. Thai Clinical Trials Registry number was TCTR20180912007. Optical biometry, encompassing measurements such as corneal thickness (CCT), keratometry, anterior chamber depth (ACD), and axial length, was conducted before and after IOP reduction. The IOL power was also determined using the SRK/T formula. The main outcomes measured were alterations in biometry and IOL power. Correlations between IOP, biometric parameters, and IOL power were analyzed. In total, 28 eyes were included in the study, with a mean patient age of 65.71±10.2 years. After IOP reduction, all biometric parameters, except CCT and ACD, exhibited a decrease without reaching statistical significance (all p>0.05). Meanwhile, IOL power showed a slight increase of 0.214±0.42 diopters (P = 0.035). The correlation between IOP and biometric parameters was found to be weak. However, there was a moderate correlation between IOP and IOL power (r2 = 0.267). Notably, IOL power tended to increase by more than 0.5 diopters when IOP decreased by more than 10 mmHg (p < 0.001). In conclusion, changes in IOP among patients with POAG and OHT do not significantly impact biometry and IOL power calculations. Nonetheless, it may be prudent to consider a slight adjustment in IOL power when IOP is lowered by more than 10 mmHg.
Collapse
|
3
|
Leshno A, Bommakanti N, De Moraes CG, Gordon MO, Kass MA, Cioffi GA, Liebmann JM. Visual field progression patterns in the ocular hypertension treatment study correspond to vulnerability regions of the disc. Eye (Lond) 2024; 38:1549-1555. [PMID: 38355667 PMCID: PMC11126578 DOI: 10.1038/s41433-024-02949-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 12/25/2023] [Accepted: 01/23/2024] [Indexed: 02/16/2024] Open
Abstract
OBJECTIVES To determine the locations on the 24-2 visual field (VF) testing grid that are most likely to progress in patients with ocular hypertension (OHTN). Based on a structural model of superior and inferior areas of relative vulnerability at the optic disc, we hypothesized that the nasal and paracentral regions are more prone to show a reduction in sensitivity. METHODS Posthoc analysis of data collected in phases 1 and 2 of the Ocular Hypertension Treatment Study (OHTS). A pointwise analysis was applied to determine the progression patterns in the early and delayed treatment groups. Each group's progression rate and frequency were calculated for each of the 52 locations corresponding to the 24-2 VF strategy, using trend- and event-based analyses, respectively. RESULTS For the event-based analysis, the events were most commonly found in the nasal and paracentral regions. The same regions, with some modest variation, were found to have the fastest rates of progression (ROP) measured with trend analysis. A similar pattern of progression was observed in both the early and delayed treatment groups. The difference in event rates and ROP between the early and delayed treatment groups was also greatest in the nasal and paracentral regions. CONCLUSIONS Development of VF loss in ocular hypertensive eyes appears to be consistent with the vulnerability zones previously described in glaucomatous eyes with established VF loss. Ocular hypotensive treatment likely helps to slow the rate of progression in these regions. This suggests that careful monitoring of these locations may be useful.
Collapse
|
4
|
Mesfin Y, Kong A, Backus BT, Deiner M, Ou Y, Oatts JT. Pilot study comparing a new virtual reality-based visual field test to standard perimetry in children. J AAPOS 2024; 28:103933. [PMID: 38729256 DOI: 10.1016/j.jaapos.2024.103933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 02/07/2024] [Accepted: 02/11/2024] [Indexed: 05/12/2024]
Abstract
PURPOSE To assess the feasibility and performance of Vivid Vision Perimetry (VVP), a new virtual reality (VR)-based visual field platform. METHODS Children 7-18 years of age with visual acuity of 20/80 or better undergoing Humphrey visual field (HVF) testing were recruited to perform VVP, a VR-based test that uses suprathreshold stimuli to test 54 field locations and calculates a fraction seen score. Pearson correlation coefficients were calculated to evaluate correlation between HVF mean sensitivity and VVP mean fraction seen scores. Participants were surveyed regarding their experience. RESULTS A total of 37 eyes of 23 participants (average age, 12.9 ± 3.1 years; 48% female) were included. All participants successfully completed VVP testing. Diagnoses included glaucoma (12), glaucoma suspect (7), steroid-induced ocular hypertension (3), and craniopharyngioma (1). Sixteen participants had prior HVF experience, and none had prior VVP experience, although 7 had previously used VR. Of the 23 HVF tests performed, 9 (39%) were unreliable due to fixation losses, false positives, or false negatives. Similarly, 35% of VVP tests were unreliable (as defined by accuracy of blind spot detection). Excluding unreliable HVF tests, the correlation between HVF average mean sensitivity and VVP mean fraction seen score was 0.48 (P = 0.02; 95% CI, 0.09-0.74). When asked about preference for the VVP or HVF examination, all participants favored the VVP, and 70% were "very satisfied" with VVP. CONCLUSIONS In our cohort of 23 pediatric subjects, VVP proved to be a clinically feasible VR-based visual field testing, which was uniformly preferred over HVF.
Collapse
|
5
|
Muñoz-Negrete FJ, Topouzis F, Oddone F, Nisslé S, Rokicki D, Januleviciene I, Harasymowycz P, Stalmans I. Preservative-Free Bimatoprost 0.01% Ophthalmic Gel for Glaucoma Therapy: A Phase III Randomized Controlled Trial. J Glaucoma 2024; 33:422-430. [PMID: 38506750 PMCID: PMC11146180 DOI: 10.1097/ijg.0000000000002371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 02/05/2024] [Indexed: 03/21/2024]
Abstract
PRCIS Noninferiority of efficacy was demonstrated for a preservative-free bimatoprost 0.01% compared with BAK-containing bimatoprost 0.01% following a 12-week treatment period in patients with open angle glaucoma or ocular hypertension. Improved tolerability, in particular conjunctival hyperemia, was also observed. PURPOSE To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of a preservative-free bimatoprost 0.01% ophthalmic gel (PFB 0.01% gel) compared with preserved bimatoprost 0.01% (PB 0.01%). DESIGN Phase III, international, multicenter, randomized, 2-parallel group, investigator-masked, 3-month treatment duration. METHODS Patients with glaucoma or ocular hypertension were randomized after a 7-week run-in/washout period to receive once-daily PFB 0.01% gel (n=236) or PB 0.01% (n=249) for 3 months. The primary efficacy measure was changed from baseline in IOP at week 12. Safety measures included adverse events (AEs) and assessment of conjunctival hyperemia. RESULTS The mean changes from baseline in IOP at week 12 in the PFB 0.01% gel and PB 0.01% were -9.72±2.97 and -9.47±3.06 mm Hg, respectively, at 8 am , -9.41±3.03 and -9.19±3.12 mm Hg at 10 am , and -8.99±3.36 and -8.54±3.44 mm Hg at 4 pm . Noninferiority of PFB 0.01% gel to PB 0.01% was demonstrated at week 12 based on predetermined criteria (upper 95% CI margin of 1.5 mmHg at all time points). The most frequently reported AE was conjunctival hyperemia; 13 (5.5%) patients with PFB 0.01% gel and 17 (6.8%) patients with PB 0.01%. The percentage of patients experiencing a worsening from baseline in conjunctival hyperemia score was lower with PFB 0.01% gel compared to PB 0.01% at week 6 (20.1% vs. 29.3%, respectively) and week 12 (18.3% vs. 30.4%, respectively). CONCLUSIONS PFB 0.01% ophthalmic gel has the same efficacy in lowering IOP as PB 0.01% and demonstrated less aggravation of conjunctival hyperemia at weeks 6 and 12.
Collapse
|
6
|
Tan JCK, Agar A, Kalloniatis M, Phu J. Quantification and Predictors of Visual Field Variability in Healthy, Glaucoma Suspect, and Glaucomatous Eyes Using SITA-Faster. Ophthalmology 2024; 131:658-666. [PMID: 38110124 DOI: 10.1016/j.ophtha.2023.12.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 11/27/2023] [Accepted: 12/12/2023] [Indexed: 12/20/2023] Open
Abstract
PURPOSE The newly released Swedish Interactive Thresholding Algorithm (SITA)-Faster (SFR) has significantly shorter testing durations compared with older SITA algorithms, but its variability is uncertain. This study quantified and established threshold limits of test-retest variability across the 24-2 test grid using SFR. DESIGN Cross-sectional study with prospective longitudinal arm. PARTICIPANTS 1426 eyes of 787 patients with healthy, suspected glaucoma, or manifest glaucoma eyes from hospital- and university- eye clinics. METHODS Two SFR tests per eye at a baseline visit and at two follow-up visits. MAIN OUTCOME MEASURES Pointwise variability measured by test-retest difference in pointwise sensitivity between tests one and two, mean global variability (test-retest variance) measured by average of pointwise variability for each participant, global sensitivity, and reliability indices of each eye. RESULTS Of the 1426 eyes, 540 eyes (37.9%) had a diagnosis of glaucoma, 753 eyes (52.8%) were suspected of having glaucoma, and the remaining 133 eyes (9.3%) were healthy. Of 74 152 pointwise sensitivities obtained, the mean test-retest difference was 2.17 ± 2.9 dB, whereas the mean test-retest variance for each participant was 2.17 ± 1.2 dB. Pointwise and global variability increased with worsening threshold sensitivity and (MD), respectively, and was greater for peripheral compared with central test locations. In the longitudinal cohort, no significant difference in mean test-retest variance was found across the 3 visits (mean variability, 2.10 dB vs. 2.16 dB vs. 2.16 dB at visits F0 vs. F1 vs. F2; P = 0.53, repeated-measures analysis of variance). Baseline MD (-0.19 dB; 95% CI, -0.22 to 0.16 dB; P < 0.0001) and abnormally high sensitivity on glaucoma hemifield test (1.14 dB; 95% CI, 0.78-1.51 dB; P < 0.0001) were significantly associated with increased variability. Finally, test-retest MD showed minimal change around the recommended 15% false-positive cutoff threshold. CONCLUSIONS The variability of SFR increases with worsening threshold sensitivity, is stable over time, and is greater for peripheral compared with central test locations. Worse baseline MD and abnormally high sensitivity are significant predictors of increased variability. A cutoff of 15% in false-positive results may be inappropriate as a threshold for judging test reliability in SFR. FINANCIAL DISCLOSURE(S) The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Collapse
|
7
|
Novack GD. Regulation of Ophthalmic Ocular Hypotensive Drug Approval in the United States Over the Past 140 Years. Am J Ophthalmol 2024; 262:A1-A3. [PMID: 38417571 DOI: 10.1016/j.ajo.2024.02.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/13/2024] [Accepted: 02/16/2024] [Indexed: 03/01/2024]
|
8
|
Bouhout S, Bachour K, Harasymowycz P, Jaworski L, Wang Q, Durr GM. Gonioscopy-Assisted Transluminal Trabeculotomy in Uveitis-Related Ocular Hypertension and Glaucoma. J Glaucoma 2024; 33:464-472. [PMID: 38506842 DOI: 10.1097/ijg.0000000000002376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 02/16/2024] [Indexed: 03/21/2024]
Abstract
PRCIS Gonioscopy-assisted transluminal trabeculotomy (GATT) may be an effective first-line surgery for decreasing intraocular pressure (IOP) and medication burden in patients with uveitis-related ocular hypertension (OHT) or glaucoma. OBJECTIVE The purpose of the study is to determine the efficacy of GATT in lowering IOP in uveitis-related OHT or glaucoma. METHODS Retrospective case series that included patients with uveitis-related OHT or glaucoma who underwent GATT with or without concomitant cataract extraction and intraocular lens implantation at 2 Canadian academic centres from July 2018 to May 2022. Primary outcomes were: complete (no medications) and qualified success (with medication), and failure defined as (1) IOP >21 mm Hg with maximal medical therapy, (2) the need for additional glaucoma procedure, (3) loss of light perception secondary to glaucoma, and (4) IOP <6 mm Hg for 3 months. RESULTS Twenty-one eyes from 18 patients were included with a mean preoperative IOP of 26.2 ± 7.3 mm Hg on 4.3 ± 0.7 classes of glaucoma drops. The average follow-up was 29.2 ± 17.6 months and 76% of eyes (n = 16) had reached at least 12 months of follow-up. At the 12-month follow-up visit, there was a significant decrease in average IOP by 9.9 ± 7.9 mm Hg (38%, P = 0.005) and a decrease of 1.9 in glaucoma medication classes ( P = 0.002). Of eyes, 14% achieved complete success, whereas 80% of eyes achieved qualified success. Six eyes failed (29%) and 5 patients (24%) required additional glaucoma surgery. The most common postoperative complication was hyphema (n = 9; 43%). CONCLUSION This small case series suggests that GATT may be an effective first-line surgery for decreasing IOP and medication burden in patients with uveitis-related OHT or glaucoma. Further studies with longer follow-ups should be conducted to assess its long-term outcomes.
Collapse
|
9
|
Nishida T, Weinreb RN, Tansuebchueasai N, Wu JH, Meller L, Mahmoudinezhad G, Gunasegaran G, Adelpour M, Moghimi S. Smoking Intensity is Associated With Progressive Optic Nerve Head Vessel Density Loss in Glaucoma. J Glaucoma 2024; 33:394-399. [PMID: 38647412 DOI: 10.1097/ijg.0000000000002410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 03/24/2024] [Indexed: 04/25/2024]
Abstract
PRCIS A lifetime history of greater smoking consumption was associated with faster vessel density loss over time. Smoking intensity should be considered when assessing the risk of glaucoma progression, as well as its management. PURPOSE To investigate the relationship of smoking and smoking intensity, with the rate of optic nerve head (ONH) whole image capillary density (wiCD) loss in primary open angle glaucoma (POAG) and glaucoma suspect patients. METHODS In this longitudinal study, patients with POAG who had at least 2 years of follow-up and optical coherence tomography angiography (OCTA) performed at a minimum of 4 visits were selected for study. The smoking intensity was calculated as the pack-year at the baseline OCTA. Univariable and multivariable linear mixed models were used to determine the effect of each parameter on the rates of wiCD loss over time. Nonlinear least-squares estimation with piecewise regression model was used to investigate the cutoff point for the relationship between wiCD loss and smoking intensity. RESULTS One hundred sixty-four eyes (69 glaucoma suspect and 95 POAG) of 110 patients were included with a mean (95% CI) follow-up of 4.0 (3.9 to 4.1) years. Of the 110 patients, 50 (45.5%) had a reported history of smoking. Greater smoking intensity was associated with faster wiCD loss [-0.11 (-0.23 to 0.00)] %/year per 10 pack-year higher; P =0.048) after adjusting for covariates. The wiCD thinning became significantly faster when smoking intensity was greater than 22.2 pack-years. Smoking had no effect on the rate of wiCD thinning in patients who smoked <22.2 pack-years during their lifetime. CONCLUSIONS A history of greater smoking consumption was associated with faster vessel density loss, suggesting smoking intensity as a potential risk factor for glaucoma.
Collapse
|
10
|
Leshno A, Garg Shukla A, Liebmann JM. Is it Time to Revisit Glaucoma Suspect Nomenclature? Ophthalmol Glaucoma 2024; 7:219-221. [PMID: 38493388 DOI: 10.1016/j.ogla.2024.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/06/2024] [Accepted: 02/09/2024] [Indexed: 03/18/2024]
|
11
|
Lu Y, Hua Y, Wang B, Zhong F, Theophanous A, Tahir S, Lee PY, Sigal IA. The Robust Lamina Cribrosa Vasculature: Perfusion and Oxygenation Under Elevated Intraocular Pressure. Invest Ophthalmol Vis Sci 2024; 65:1. [PMID: 38691092 PMCID: PMC11077910 DOI: 10.1167/iovs.65.5.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 03/21/2024] [Indexed: 05/03/2024] Open
Abstract
Purpose Elevated intraocular pressure (IOP) is thought to cause lamina cribrosa (LC) blood vessel distortions and potentially collapse, adversely affecting LC hemodynamics, reducing oxygenation, and triggering, or contributing to, glaucomatous neuropathy. We assessed the robustness of LC perfusion and oxygenation to vessel collapses. Methods From histology, we reconstructed three-dimensional eye-specific LC vessel networks of two healthy monkey eyes. We used numerical simulations to estimate LC perfusion and from this the oxygenation. We then evaluated the effects of collapsing a fraction of LC vessels (0%-36%). The collapsed vessels were selected through three scenarios: stochastic (collapse randomly), systematic (collapse strictly by the magnitude of local experimentally determined IOP-induced compression), and mixed (a combination of stochastic and systematic). Results LC blood flow decreased linearly as vessels collapsed-faster for stochastic and mixed scenarios and slower for the systematic one. LC regions suffering severe hypoxia (oxygen <8 mm Hg) increased proportionally to the collapsed vessels in the systematic scenario. For the stochastic and mixed scenarios, severe hypoxia did not occur until 15% of vessels collapsed. Some LC regions had higher perfusion and oxygenation as vessels collapsed elsewhere. Some severely hypoxic regions maintained normal blood flow. Results were equivalent for both networks and patterns of experimental IOP-induced compression. Conclusions LC blood flow was sensitive to distributed vessel collapses (stochastic and mixed) and moderately vulnerable to clustered collapses (systematic). Conversely, LC oxygenation was robust to distributed vessel collapses and sensitive to clustered collapses. Locally normal flow does not imply adequate oxygenation. The actual nature of IOP-induced vessel collapse remains unknown.
Collapse
|
12
|
Lozano DC, Yang YF, Cepurna WO, Smoody BF, Ing E, Morrison JC, Keller KE. Profiling IOP-Responsive Genes in the Trabecular Meshwork and Optic Nerve Head in a Rat Model of Controlled Elevation of Intraocular Pressure. Invest Ophthalmol Vis Sci 2024; 65:41. [PMID: 38809543 PMCID: PMC11146053 DOI: 10.1167/iovs.65.5.41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 05/09/2024] [Indexed: 05/30/2024] Open
Abstract
Purpose The rat controlled elevation of intraocular pressure (CEI) model allows study of in vivo responses to short-term exposure to defined intraocular pressures (IOP). In this study, we used NanoString technology to investigate in vivo IOP-related gene responses in the trabecular meshwork (TM) and optic nerve head (ONH) simultaneously from the same animals. Methods Male and female rats (N = 35) were subjected to CEI for 8 hours at pressures simulating mean, daytime normotensive rat IOP (CEI-20), or 2.5× IOP (CEI-50). Naïve animals that received no anesthesia or surgical interventions served as controls. Immediately after CEI, TM and ONH tissues were dissected, RNA was isolated, and samples were analyzed with a NanoString panel containing 770 genes. Postprocessing, raw count data were uploaded to ROSALIND for differential gene expression analyses. Results For the TM, 45 IOP-related genes were significant in the CEI-50 versus CEI-20 and CEI-50 versus naïve comparisons, with 15 genes common to both comparisons. Bioinformatics analysis identified Notch and transforming growth factor beta (TGFβ) pathways to be the most up- and downregulated Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways, respectively. For ONH, 22 significantly differentially regulated genes were identified in the CEI-50 versus naïve comparison. Pathway analysis identified defense response and immune response as two significantly upregulated biological process pathways. Conclusions This study demonstrated the ability to assay short-term IOP-responsive genes in both TM and ONH tissues simultaneously. In the TM, downregulation of TGFβ pathway genes suggests that TM responses may reduce TGFβ-induced extracellular matrix synthesis. For ONH, the initial response to short-term elevated IOP may be protective.
Collapse
|
13
|
Barathi VA, Katz A, Chaudhary S, Li HL, Tal DM, Marcovich A, Do CW, Karlish SJD. A digoxin derivative that potently reduces intraocular pressure: efficacy and mechanism of action in different animal models. Am J Physiol Cell Physiol 2024; 326:C1505-C1519. [PMID: 38557355 DOI: 10.1152/ajpcell.00617.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 03/25/2024] [Accepted: 03/27/2024] [Indexed: 04/04/2024]
Abstract
Glaucoma is a blinding disease. Reduction of intraocular pressure (IOP) is the mainstay of treatment, but current drugs show side effects or become progressively ineffective, highlighting the need for novel compounds. We have synthesized a family of perhydro-1,4-oxazepine derivatives of digoxin, the selective inhibitor of Na,K-ATPase. The cyclobutyl derivative (DcB) displays strong selectivity for the human α2 isoform and potently reduces IOP in rabbits. These observations appeared consistent with a hypothesis that in ciliary epithelium DcB inhibits the α2 isoform of Na,K-ATPase, which is expressed strongly in nonpigmented cells, reducing aqueous humor (AH) inflow. This paper extends assessment of efficacy and mechanism of action of DcB using an ocular hypertensive nonhuman primate model (OHT-NHP) (Macaca fascicularis). In OHT-NHP, DcB potently lowers IOP, in both acute (24 h) and extended (7-10 days) settings, accompanied by increased aqueous humor flow rate (AFR). By contrast, ocular normotensive animals (ONT-NHP) are poorly responsive to DcB, if at all. The mechanism of action of DcB has been analyzed using isolated porcine ciliary epithelium and perfused enucleated eyes to study AH inflow and AH outflow facility, respectively. 1) DcB significantly stimulates AH inflow although prior addition of 8-Br-cAMP, which raises AH inflow, precludes additional effects of DcB. 2) DcB significantly increases AH outflow facility via the trabecular meshwork (TM). Taken together, the data indicate that the original hypothesis on the mechanism of action must be revised. In the OHT-NHP, and presumably other species, DcB lowers IOP by increasing AH outflow facility rather than by decreasing AH inflow.NEW & NOTEWORTHY When applied topically, a cyclobutyl derivative of digoxin (DcB) potently reduces intraocular pressure in an ocular hypertensive nonhuman primate model (Macaca fascicularis), associated with increased aqueous humor (AH) flow rate (AFR). The mechanism of action of DcB involves increased AH outflow facility as detected in enucleated perfused porcine eyes and, in parallel, increased (AH) inflow as detected in isolated porcine ciliary epithelium. DcB might have potential as a drug for the treatment of open-angle human glaucoma.
Collapse
|
14
|
Tatti F, Lixi F, Demarinis G, Napoli P, Fossarello M. Anterior Segment Optical Coherence Tomography for Cases of High Intraocular Pressure Following XEN Implant for Glaucoma. J Glaucoma 2024; 33:375-380. [PMID: 38129940 DOI: 10.1097/ijg.0000000000002350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 11/25/2023] [Indexed: 12/23/2023]
Abstract
PRCIS This study showed that the XEN patency should be verified by OCT imaging in cases of encapsulated blebs. Although fibrosis plays the principal role, humor aqueous flow reduction could affect the "spacer" effect that inhibits the fibroblast attachments. PURPOSE To evaluate the application of the anterior segment optical coherence tomography (AS-OCT) imaging in studying the relationship between a low flow rate through the XEN63 and the development of a cystic bleb. METHODS Retrospective case series of 3 eyes presenting a cystic bleb after an XEN63 implantation for uncontrolled intraocular pressure (IOP). Demographic and clinical data were obtained from medical records. The imaging findings, complications, and managements following the surgery were evaluated. RESULTS Three patients, with an average age of 67.3 years, initially showed a patent stent lumen and a functional bleb after surgery. The IOP of all eyes increased on average at 28.3 days from the surgery, with a mean value of 39.66 mm Hg. The slit lamp examination showed a cystic bleb. The AS-OCT imaging confirmed the previous finding and revealed either a partial or total occlusion of the stent internal ostium. A Nd:YAG laser, in proximity to the ostium, was performed to resolve the obstruction. Although the AS-OCT imaging showed the device patency and the IOP immediately decreased, the latter became elevated again. Consequently, in all the cases, a further needling procedure was needed to achieve an adequate IOP reduction. Six months after the two-step procedure, the IOP averaged 13.33 mm Hg, the XEN63 lumens appeared cleared, and the blebs showed a functional morphology. No adverse events were observed. CONCLUSION The development of a cystic bleb may result from an altered balance between the flow rate through the XEN63 and the fibrosis development in the postoperative healing process. A proper follow-up based on slit lamp biomicroscopy, IOP measurement, and AS-OCT imaging is advisable to estimate and manage a cystic bleb following XEN63 implantation.
Collapse
|
15
|
Shi Y, Chen X, Tian Q, Bi C. OCTA on the density of optic nerve microvessels in myopic population with ocular hypertension. Photodiagnosis Photodyn Ther 2024; 46:104013. [PMID: 38346468 DOI: 10.1016/j.pdpdt.2024.104013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/06/2024] [Accepted: 02/09/2024] [Indexed: 02/29/2024]
Abstract
OBJECTIVE To measure functional, structural, and blood flow parameters of the optic disk in myopic patients with ocular hypertension (OHT) and myopic patients using optical coherence tomography angiography (OCTA), this study aims to investigate the variability of each parameter between the two groups, and to analyze the correlation between the RNFL thickness and blood flow parameters, as well as the diagnostic value of these blood flow parameters for myopic patients with OHT. METHODS This was a cross-sectional study. Myopic adults who were attending the Eye Center of Jinan Second People's Hospital between December 2020 and January 2022, and who had a confirmed diagnosis of OHT, were enrolled. This cohort constituted the myopic group. In these subjects, retinal nerve fiber layer (RNFL) thickness and blood flow parameters within the superficial optic disk 6 × 6 mm area were measured using OCTA. The optic disk blood flow parameters included radial peripapillary capillaries (RPC) perfusion density (PD) in nasal, temporal, superior, and inferior sectors. Visual field assessments were conducted using a Humphrey visual field meter to obtain the visual field index (VFI) and pattern standard deviation (PSD). SPSS 22.0 statistical software was utilized to determine if statistical differences existed between the parameters of the two groups and to analyze the correlation between blood flow parameters and RNFL thickness. Additionally, the area under the subject's operating characteristic curve (AUROC) was used to assess the diagnostic value of blood flow parameters for myopic patients with OHT. RESULTS There was no statistical difference in PSD and VFI in the OHT group compared with the myopic group (P = 0.351, 0.242). The RNFL thickness was (103.64 ± 8.13) μm and (97.56 ± 12.94) μm in the myopic and OHT groups, respectively. There was no statistical difference in RNFL thickness between the OHT and myopic group (P = 0.052). The PD of radial peripapillary capillaries (RPC) in nasal, temporal, superior, and inferior sectors showed an overall decreasing trend between the myopic and OHT groups, but there was a statistical difference only in the temporal sector (P = 0.008). Correlation analysis of blood flow parameters and structural parameters showed that the PD in the temporal sector and RNFL thickness were not correlated (P = 0.263). By plotting the AUROC of blood flow parameter, it was found that OCTA had good value in diagnosing myopic patients with OHT, and the PD of the temporal sector had higher diagnostic value for differentiating the OHT group from myopic group (AUROC = 0.718, P = 0.008) CONCLUSIONS: Compared with the myopic group, blood flow parameters decreased in the OHT group, while structural and functional parameters did not change significantly, suggesting that blood flow damage may have occurred earlier in myopic patients with OHT, by the correlation analysis between structural and blood flow parameters. OCTA has good diagnostic value for myopic patients with OHT.
Collapse
|
16
|
Coskun C, Çelik G, Zeki Fikret C, Çomçalı S, Evren Kemer Ö. Evaluation of corneal densitometry values with Pentacam in cases of ocular hypertension and pseudoexfoliative glaucoma. Photodiagnosis Photodyn Ther 2024; 46:103988. [PMID: 38368915 DOI: 10.1016/j.pdpdt.2024.103988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 01/19/2024] [Accepted: 01/22/2024] [Indexed: 02/20/2024]
Abstract
BACKGROUND Examination of corneal densitometry measurements using the Pentacam Scheimpflug imaging system in cases of pseudoexfoliative glaucoma (PEXG) and ocular hypertension (OHT). METHODS The study included 50 eyes of 29 PEXG patients, 25 eyes of 16 OHT patients, and 76 eyes of 38 healthy control subjects followed in the glaucoma clinic. Corneal densitometry values of all cases were measured using the Scheimpflug imaging system (Pentacam, Oculus, Germany). Corneal densitometry was assessed based on 4 concentric radial zones (0-2 mm, 2-6 mm, 6-10 mm, and 10-12 mm) and depths (anterior, central, posterior, and total) within the Scheimpflug imaging system. The results were statistically analyzed. RESULTS Corneal densitometry values examined between the OHT and control groups were higher in OHT and statistically significant (p < 0.05). Corneal densitometry values examined between the PEXG and control groups were higher in PEXG and statistically significant (p < 0.05). In comparison between the PEXG and OHT groups, corneal densitometry values in the central 0-2 mm, 2-6 mm, and 6-10 mm; posterior 0-2 mm and 2-6 mm radial zones were higher in PEXG and statistically significant (p < 0.05). CONCLUSIONS It was observed that elevated intraocular pressure levels in OHT cases could lead to changes in the cornea, consequently increasing corneal densitometry values. The higher corneal densitometry values in PEXG cases compared to OHT were attributed to the accumulation of pseudoexfoliative material in the cornea. Based on our study, corneal densitometry could serve as a potential biomarker for early glaucoma detection in OHT cases and could be employed to assess corneal transparency during the follow-up of PEXG cases.
Collapse
|
17
|
Erichev VP, Zinina VS, Safonova DM. [Minoxidil-induced ophthalmic hypertension (case report)]. Vestn Oftalmol 2024; 140:90-93. [PMID: 38739136 DOI: 10.17116/oftalma202414002290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
This article presents a case of a 31-year-old male patient who presented to the outpatient department of the Krasnov Research Institute of Eye Diseases with complaints of diplopia and increased intraocular pressure (IOP) up to 30 mm Hg. The patient had been using minoxidil topically for androgenic alopecia for 8 years. On examination, mild swelling of the bulbar conjunctiva in the upper fornix was revealed; optical coherence tomography showed thinning of the ganglion cell layer, most likely due to moderate myopia. The patient responded well to discontinuation of minoxidil and topical therapy with prostaglandin analogues. After 4 months, an attempt was made to replace topical hypotensive therapy with carbonic anhydrase inhibitors, but the previous hypotensive regimen had to be resumed due to an increase in IOP. During 10 months of observation, no signs of progression were detected according to optical coherence tomography and static perimetry.
Collapse
|
18
|
Andreeva YS, Alkharki L, Shelankova AV, Budzinskaya MV. [Topical application of hypotensive drugs for the prevention of intraocular pressure elevation after intravitreal injections of anti-VEGF drugs]. Vestn Oftalmol 2024; 140:73-79. [PMID: 38739134 DOI: 10.17116/oftalma202414002273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
The management protocol for patients with neovascular age-related macular degeneration (nAMD) involves multiple intravitreal injections (IVI) of anti-VEGF drugs. The ability to reduce the peak intraocular pressure (IOP) rise is greatly important in clinical practice. PURPOSE This study evaluates the effect of topical hypotensive drugs on the short-term IOP rise after IVI of anti-VEGF drugs in patients with nAMD. MATERIAL AND METHODS The prospective study included 80 patients with newly diagnosed nAMD. Before the start of treatment, the patients were divided into 4 groups of 20 people each: 1st - controls, who received no prophylactic drugs, in the 2nd, 3rd and 4th groups local instillations of one drop of hypotensive drugs brinzolamide 1%, brinzolamide-timolol, brimonidine-timolol were performed in the conjunctival sac twice: 1 day before the injection (at 20:00) and on the day of the injection 2 hours before the manipulation (at 08:00), respectively. IOP was measured in each patient using ICare Pro non-contact tonometer before injection, as well as 1 min, 30 and 60 min after injection. RESULTS Prophylactic use of hypotensive drugs was associated with a significant decrease in IOP immediately after IVI compared to the same parameter in the 1st group (p<0.001), the maximum decrease in IOP values was observed when using a fixed combination of brimonidine-timolol by 12.1 mm Hg compared to the controls (p<0.001), the combination of brinzolamide-timolol reduced IOP by 8.5 mm Hg (p<0.001), brinzolamide 1% led to the smallest decrease in IOP - by 5.1 mm Hg (p<0.001). CONCLUSION Study patients that received instillations of brimonidine-timolol combination of one drop into the conjunctival sac 1 day before the injection and on the day of the injection showed the maximum decrease in IOP compared to patients of the other groups.
Collapse
|
19
|
McDowell CM, Kizhatil K, Elliott MH, Overby DR, van Batenburg-Sherwood J, Millar JC, Kuehn MH, Zode G, Acott TS, Anderson MG, Bhattacharya SK, Bertrand JA, Borras T, Bovenkamp DE, Cheng L, Danias J, De Ieso ML, Du Y, Faralli JA, Fuchshofer R, Ganapathy PS, Gong H, Herberg S, Hernandez H, Humphries P, John SWM, Kaufman PL, Keller KE, Kelley MJ, Kelly RA, Krizaj D, Kumar A, Leonard BC, Lieberman RL, Liton P, Liu Y, Liu KC, Lopez NN, Mao W, Mavlyutov T, McDonnell F, McLellan GJ, Mzyk P, Nartey A, Pasquale LR, Patel GC, Pattabiraman PP, Peters DM, Raghunathan V, Rao PV, Rayana N, Raychaudhuri U, Reina-Torres E, Ren R, Rhee D, Chowdhury UR, Samples JR, Samples EG, Sharif N, Schuman JS, Sheffield VC, Stevenson CH, Soundararajan A, Subramanian P, Sugali CK, Sun Y, Toris CB, Torrejon KY, Vahabikashi A, Vranka JA, Wang T, Willoughby CE, Xin C, Yun H, Zhang HF, Fautsch MP, Tamm ER, Clark AF, Ethier CR, Stamer WD. Consensus Recommendation for Mouse Models of Ocular Hypertension to Study Aqueous Humor Outflow and Its Mechanisms. Invest Ophthalmol Vis Sci 2022; 63:12. [PMID: 35129590 PMCID: PMC8842499 DOI: 10.1167/iovs.63.2.12] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/08/2021] [Indexed: 01/07/2023] Open
Abstract
Due to their similarities in anatomy, physiology, and pharmacology to humans, mice are a valuable model system to study the generation and mechanisms modulating conventional outflow resistance and thus intraocular pressure. In addition, mouse models are critical for understanding the complex nature of conventional outflow homeostasis and dysfunction that results in ocular hypertension. In this review, we describe a set of minimum acceptable standards for developing, characterizing, and utilizing mouse models of open-angle ocular hypertension. We expect that this set of standard practices will increase scientific rigor when using mouse models and will better enable researchers to replicate and build upon previous findings.
Collapse
|
20
|
Jammal AA, Berchuck SI, Mariottoni EB, Tanna AP, Costa VP, Medeiros FA. Blood Pressure and Glaucomatous Progression in a Large Clinical Population. Ophthalmology 2022; 129:161-170. [PMID: 34474070 PMCID: PMC8792171 DOI: 10.1016/j.ophtha.2021.08.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 08/04/2021] [Accepted: 08/24/2021] [Indexed: 02/03/2023] Open
Abstract
PURPOSE To investigate the effect of systemic arterial blood pressure (BP) on rates of progressive structural damage over time in glaucoma. DESIGN Retrospective cohort study. PARTICIPANTS A total of 7501 eyes of 3976 subjects with glaucoma or suspected of glaucoma followed over time from the Duke Glaucoma Registry. METHODS Linear mixed models were used to investigate the effects of BP on the rates of retinal nerve fiber layer (RNFL) loss from spectral-domain OCT (SD-OCT) over time. Models were adjusted for intraocular pressure (IOP), gender, race, diagnosis, central corneal thickness (CCT), follow-up time, and baseline disease severity. MAIN OUTCOME MEASURE Effect of mean arterial pressure (MAP), systolic arterial pressure (SAP), and diastolic arterial pressure (DAP) on rates of RNFL loss over time. RESULTS A total of 157 291 BP visits, 45 408 IOP visits, and 30 238 SD-OCT visits were included. Mean rate of RNFL change was -0.70 μm/year (95% confidence interval, -0.72 to -0.67 μm/year). In univariable models, MAP, SAP, and DAP during follow-up were not significantly associated with rates of RNFL loss. However, when adjusted for mean IOP during follow-up, each 10 mmHg reduction in mean MAP (-0.06 μm/year; P = 0.007) and mean DAP (-0.08 μm/year; P < 0.001) but not SAP (-0.01 μm/year; P = 0.355) was associated with significantly faster rates of RNFL thickness change over time. The effect of the arterial pressure metrics remained significant after additional adjustment for baseline age, diagnosis, sex, race, follow-up time, disease severity, and corneal thickness. CONCLUSIONS When adjusted for IOP, lower MAP and DAP during follow-up were significantly associated with faster rates of RNFL loss, suggesting that levels of systemic BP may be a significant factor in glaucoma progression.
Collapse
|
21
|
Zhu Z, Waxman S, Wang B, Wallace J, Schmitt SE, Tyler-Kabara E, Ishikawa H, Schuman JS, Smith MA, Wollstein G, Sigal IA. Interplay between intraocular and intracranial pressure effects on the optic nerve head in vivo. Exp Eye Res 2021; 213:108809. [PMID: 34736887 DOI: 10.1016/j.exer.2021.108809] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 10/19/2021] [Accepted: 10/25/2021] [Indexed: 12/19/2022]
Abstract
Intracranial pressure (ICP) has been proposed to play an important role in the sensitivity to intraocular pressure (IOP) and susceptibility to glaucoma. However, the in vivo effects of simultaneous, controlled, acute variations in ICP and IOP have not been directly measured. We quantified the deformations of the anterior lamina cribrosa (ALC) and scleral canal at Bruch's membrane opening (BMO) under acute elevation of IOP and/or ICP. Four eyes of three adult monkeys were imaged in vivo with OCT under four pressure conditions: IOP and ICP either at baseline or elevated. The BMO and ALC were reconstructed from manual delineations. From these, we determined canal area at the BMO (BMO area), BMO aspect ratio and planarity, and ALC median depth relative to the BMO plane. To better account for the pressure effects on the imaging, we also measured ALC visibility as a percent of the BMO area. Further, ALC depths were analyzed only in regions where the ALC was visible in all pressure conditions. Bootstrap sampling was used to obtain mean estimates and confidence intervals, which were then used to test for significant effects of IOP and ICP, independently and in interaction. Response to pressure manipulation was highly individualized between eyes, with significant changes detected in a majority of the parameters. Significant interactions between ICP and IOP occurred in all measures, except ALC visibility. On average, ICP elevation expanded BMO area by 0.17 mm2 at baseline IOP, and contracted BMO area by 0.02 mm2 at high IOP. ICP elevation decreased ALC depth by 10 μm at baseline IOP, but increased depth by 7 μm at high IOP. ALC visibility decreased as ICP increased, both at baseline (-10%) and high IOP (-17%). IOP elevation expanded BMO area by 0.04 mm2 at baseline ICP, and contracted BMO area by 0.09 mm2 at high ICP. On average, IOP elevation caused the ALC to displace 3.3 μm anteriorly at baseline ICP, and 22 μm posteriorly at high ICP. ALC visibility improved as IOP increased, both at baseline (5%) and high ICP (8%). In summary, changing IOP or ICP significantly deformed both the scleral canal and the lamina of the monkey ONH, regardless of the other pressure level. There were significant interactions between the effects of IOP and those of ICP on LC depth, BMO area, aspect ratio and planarity. On most eyes, elevating both pressures by the same amount did not cancel out the effects. Altogether our results show that ICP affects sensitivity to IOP, and thus that it can potentially also affect susceptibility to glaucoma.
Collapse
|
22
|
Kim J, Gardiner SK, Ramazzotti A, Karuppanan U, Bruno L, Girkin CA, Downs JC, Fazio MA. Strain by virtual extensometers and video-imaging optical coherence tomography as a repeatable metric for IOP-Induced optic nerve head deformations. Exp Eye Res 2021; 211:108724. [PMID: 34375590 PMCID: PMC8511063 DOI: 10.1016/j.exer.2021.108724] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 07/27/2021] [Accepted: 08/06/2021] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine if in vivo strain response of the Optic Nerve Head (ONH) to IOP elevation visualized using Optical Coherence Tomography (OCT) video imaging and quantified using novel virtual extensometers was able to be provided repeatable measurements of tissue specific deformations. METHODS The ONHs of 5 eyes from 5 non-human primates (NHPs) were imaged by Spectralis OCT. A vertical and a horizontal B-scan of the ONH were continuously recorded for 60 s at 6 Hz (video imaging mode) during IOP elevation from 10 to 30 mmHg. Imaging was repeated over three imaging sessions. The 2D normal strain was computed by template-matching digital image correlation using virtual extensometers. ANOVA F-test (F) was used to compare inter-eye, inter-session, and inter-tissue variability for the prelaminar, Bruch's membrane opening (BMO), lamina cribrosa (LC) and choroidal regions (against variance the error term). F-test of the ratio between inter-eye to inter-session variability was used to test for strain repeatability across imaging sessions (FIS). RESULTS Variability of strain across imaging session (F = 0.7263, p = 0.4855) and scan orientation was not significant (F = 1.053, p = 0.3066). Inter session variability of strain was significantly lower than inter-eye variability (FIS = 22.63, p = 0.0428) and inter-tissue variability (FIS = 99.33 p = 0.00998). After IOP elevation, strain was highest in the choroid (-18.11%, p < 0.001), followed by prelaminar tissue (-11.0%, p < 0.001), LC (-3.79%, p < 0.001), and relative change in BMO diameter (-0.57%, p = 0.704). CONCLUSIONS Virtual extensometers applied to video-OCT were sensitive to the eye-specific and tissue-specific mechanical response of the ONH to IOP and were repeatable across imaging sessions.
Collapse
|
23
|
Roddy GW, Chowdhury UR, Monson KJ, Fautsch MP. Stanniocalcin-1 Reduced Intraocular Pressure in Two Models of Ocular Hypertension. Curr Eye Res 2021; 46:1525-1530. [PMID: 33757401 PMCID: PMC10505966 DOI: 10.1080/02713683.2021.1899246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 01/11/2021] [Accepted: 02/23/2021] [Indexed: 10/21/2022]
Abstract
Purpose/Aim: Glaucomatous optic neuropathy (GON) remains the world's leading cause of irreversible blindness. Treatments including topical medications are directed at reducing intraocular pressure (IOP), the most significant risk factor for GON. Current medications, while generally effective, are limited by insufficient response and side-effects in some patients. In search of a more targeted therapy that acts downstream of existing medications that has a potential for a lower side effect profile, our laboratory has identified Stanniocalcin-1 (STC-1), a multifunctional hormone, as an effector molecule in latanoprost-mediated IOP reduction with similar IOP-lowering efficacy as latanoprost in normotensive mice.Materials and methods: To investigate whether STC-1 can also reduce IOP in ocular hypertensive mice, we used a steroid-induced ocular hypertensive mouse model characterized by trabecular meshwork dysfunction as well as the DBA/2J mouse as an inherited model of pigment dispersion and secondary angle closure. Steroid-induced ocular hypertension was induced by weekly injections of dexamethasone into the conjunctival fornix of wild-type C57BL/6J mice (6-8 months old). After confirmation of the steroid response, mice were administered STC-1 or phosphate buffered saline (PBS) topically once daily for six weeks. For DBA/2J mice (14 months old), after baseline IOP measurements, mice were treated topically once daily with STC-1 or PBS for 5 days and IOP was assessed twice daily.Results: In steroid-induced ocular hypertensive mice, STC-1 lowered IOP by 26% (P < .001, week three) and maintained this level of IOP reduction throughout the remainder of the treatment period (P < .001, week six). In DBA/2J mice, STC-1 lowered IOP by 37% (P < .001).Conclusions: Together, these data show that STC-1 reduced IOP in two models of ocular hypertension with different mechanisms of outflow obstruction.
Collapse
|
24
|
Rezkallah A, Mathis T, Abukhashabah A, Voirin N, Malclès A, Agard É, Lereuil T, Denis P, Dot C, Kodjikian L. LONG-TERM INCIDENCE AND RISK FACTORS OF OCULAR HYPERTENSION FOLLOWING DEXAMETHASONE-IMPLANT INJECTIONS: THE SAFODEX-2 STUDY. Retina 2021; 41:1438-1445. [PMID: 33315814 DOI: 10.1097/iae.0000000000003080] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To analyze the incidence, risk factors, and time to onset of ocular hypertension (OHT) after intravitreal injections (IVI) of dexamethasone implant and to evaluate the long-term cumulative probability of intraocular pressure elevation. METHODS Eyes of patients having received at least one dexamethasone implant IVI between October 2010 and February 2015 were included in the present study. Ocular hypertension was defined as intraocular pressure > 25 mmHg and/or an increase of 10 mmHg over the follow-up period compared with baseline intraocular pressure. RESULTS Four hundred ninety-four eyes were studied in 410 patients. For a total of 1,371 IVI, the incidence of OHT was 32.6% in the study eyes with a mean follow-up period of 30 months (3-62.5) and a median follow-up of 29 months. Pressure-lowering treatment was introduced for 36.9% of eyes. Topical treatment alone was sufficient to manage OHT in 97%. Young age, male sex, uveitis and retinal vein occlusion, and glaucoma treated with a double- or triple-combination topical pressure-lowering medication were found to be risk factors for OHT. The incidence of OHT did not change with an increase in the number of IVI, and there was no cumulative effect, defining by an increase of the incidence of OHT in patients after repeated IVI (P = 0.248). CONCLUSION This study confirmed that OHT is of moderate incidence, transient, controlled by topical treatment and provides data on the long-term cumulative probability of intraocular pressure elevation in a large cohort of eyes treated with dexamethasone implant IVI. Repeat injections of dexamethasone implant neither increase nor decrease the risk of OHT.
Collapse
|
25
|
Mead B, Kerr A, Nakaya N, Tomarev SI. miRNA Changes in Retinal Ganglion Cells after Optic Nerve Crush and Glaucomatous Damage. Cells 2021; 10:1564. [PMID: 34206213 PMCID: PMC8305746 DOI: 10.3390/cells10071564] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Revised: 06/11/2021] [Accepted: 06/18/2021] [Indexed: 12/25/2022] Open
Abstract
The purpose of this study was to characterize the miRNA profile of purified retinal ganglion cells (RGC) from healthy and diseased rat retina. Diseased retina includes those after a traumatic optic nerve crush (ONC), and after ocular hypertension/glaucoma. Rats were separated into four groups: healthy/intact, 7 days after laser-induced ocular hypertension, 2 days after traumatic ONC, and 7 days after ONC. RGC were purified from rat retina using microbeads conjugated to CD90.1/Thy1. RNA were sequenced using Next Generation Sequencing. Over 100 miRNA were identified that were significantly different in diseased retina compared to healthy retina. Considerable differences were seen in the miRNA expression of RGC 7 days after ONC, whereas after 2 days, few changes were seen. The miRNA profiles of RGC 7 days after ONC and 7 days after ocular hypertension were similar, but discrete miRNA differences were still seen. Candidate mRNA showing different levels of expression after retinal injury were manipulated in RGC cultures using mimics/AntagomiRs. Of the five candidate miRNA identified and subsequently tested for therapeutic efficacy, miR-194 inhibitor and miR-664-2 inhibitor elicited significant RGC neuroprotection, whereas miR-181a mimic and miR-181d-5p mimic elicited significant RGC neuritogenesis.
Collapse
|