226
|
Ivanoff CS, Hottel TL, Garcia-Godoy F. Influence of a cylindrical crosshead on shear bond testing of composite-tooth interfaces. Dent Mater J 2018; 37:865-873. [PMID: 29998942 DOI: 10.4012/dmj.2017-348] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The effect of a cylindrical crosshead on shear bond strength of composite to dentin was assessed by finite element analysis (FEA) after shear bond testing thirty mandibular molars restored with composite cylinders (Tetric EvoCeram-3 mm diameter) perpendicular to conditioned dentin. Cross-sectional geometric models were created with quadrilateral linear plane stress elements. Stress distributions for normal, shear, and major principal stresses were plotted. Mean shear bond strength for the experimental group was 23.9 MPa (±4.54), about 15-75% higher than values reported with other methods. FEA showed localized 'hot spots' (±16-20 MPa) at the corners of the base of the adhesive layer under a 20 N vertical load. Principal stresses across the composite-dentin interface were lower (±12-16 MPa), but significantly homogenous, approximating closely the nominal strength value. With uniform stress distributions across the adhesive layer, FEA confirmed that a cylindrical crosshead may be an optional tool to improve shear bond testing of dental materials.
Collapse
|
227
|
Daratsianos N, Schütz B, Reimann S, Weber A, Papageorgiou SN, Jäger A, Bourauel C. The influence of enamel sandblasting on the shear bond strength and fractography of the bracket-adhesive-enamel complex tested in vitro by the DIN 13990:2017-04 standard. Clin Oral Investig 2018; 23:2975-2985. [PMID: 30426265 DOI: 10.1007/s00784-018-2692-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Accepted: 10/02/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVES This study was conducted in order to investigate whether enamel sandblasting as an adjunct or substitute to the acid-etch technique has an effect on the shear bond strength (SBS) and fractography of the bracket-adhesive-enamel complex using the DIN 13990:2017-04 standard. MATERIALS AND METHODS Upper central incisor brackets (discovery®, Dentaurum, Germany) were bonded using Transbond XT™ (3M Unitek, Germany) on bovine incisors prepared by four different methods (15 samples each): sandblasting with 27 μm Al2O3 at 1.2 bar (s), acid etching with 37.4% phosphoric acid (a), sandblasting with 27 μm Al2O3 at 1.2 bar followed by acid etching (s1a), and sandblasting with 50 μm Al2O3 at 5.7 bar followed by acid etching (s2a). The SBS and adhesive remnant index (ARI) were measured, followed by one-way analysis of variance and Fisher's exact tests at 5%. RESULTS The SBS in groups s (5.6 ± 2.2 MPa), a (17.1 ± 4.3 MPa), s1a (18.3 ± 4.3 MPa), and s2a (18.5 ± 4.6 MPa) indicated that the s group was significantly inferior to all the other groups (p < 0.001). Likewise, the ARI analysis indicated a different performance of the s group (mostly ARI of 0) compared to the other groups (p < 0.001) and a tendency for different ARI between the a and s1a/s2a groups. CONCLUSIONS In vitro enamel sandblasting could not substitute acid etching and did not offer improved SBS when used before acid etching, regardless of air pressure and powder granulation. Sandblasting without acid etching produced less residual resin on the tooth after debonding. CLINICAL RELEVANCE The clinical use of adjunct enamel sandblasting prior to etching to enhance SBS has to be questioned.
Collapse
|
228
|
Hiraba H, Nogawa H, Koizumi H, Kodaira A, Akahane S. Effect of multi-purpose primers on the bond durability between tri-n-butylborane initiated resin and gold alloy. J Prosthodont Res 2018; 63:95-99. [PMID: 30385330 DOI: 10.1016/j.jpor.2018.09.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Revised: 08/24/2018] [Accepted: 09/28/2018] [Indexed: 11/25/2022]
Abstract
PURPOSE This study investigated the influence of an interaction between sulfur-containing monomers and other monomers in multipurpose primers on the bond durability of a tri-n-butylborane (TBB)-initiated acrylic resin to a gold alloy. METHODS The disk-shaped adherend materials were prepared from a gold alloy (Casting Gold M.C. Type IV). Two multipurpose-primers (Universal Primer, Monobond Plus), four metal primers containing an organic sulfur compound (M.L. Primer, Alloy Primer, Metaltite, and V-Primer), and three acidic primers (Estenia Opaque Primer, Acryl Bond, and Super-Bond Liquid) were used. The shear bond strengths were determined pre- and post-thermocycling to evaluate the bond durability. A statistical analysis of the results was performed using a non-parametric procedure, and the cohesive failure ratios of the debonded surfaces were compared. RESULTS Among the pre-thermocycling groups, M.L. Primer, Metaltite, Monobond Plus, Universal Primer, and Alloy Primer showed the greatest bond strengths. Among the post-thermocycling groups, M.L. Primer, Metaltite, Monobond Plus, and Universal Primer showed the greatest bond strengths, whereas Acryl Bond, Super-Bond Liquid, Estenia Opaque Primer, and the unprimed control showed the lowest. Similarly, the primers that did not contain either a sulfur compound showed an obvious reduction in the cohesive failure ratio. CONCLUSIONS Multi-purpose primers containing a sulfur-containing monomer increased the bond strength of a TBB-initiated acrylic resin to a gold alloy. The proportion of the area of cohesive failure to the bonded area showed an interrelationship with the shear bond strength testing results.
Collapse
|
229
|
Coelho A, Canta JP, Martins JNR, Arantes-Oliveira S, Marques PF. Influence of self-etch all-in-one adhesives on fissure sealant shear bond strength under contaminated enamel conditions. Eur Arch Paediatr Dent 2018; 20:15-22. [PMID: 30328065 DOI: 10.1007/s40368-018-0378-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 08/12/2018] [Indexed: 10/28/2022]
Abstract
AIM To determine the influence of two all-in-one self-etching adhesive systems on shear bond strength of a fissure sealant applied under different enamel surface conditions. METHODS A total of 180 bovine enamel specimens were randomly distributed to nine experimental groups, defined by the combination of the sealant application technique (using phosphoric acid, or a self-etching water-based adhesive or a self-etching ethanol and water-based adhesive) and enamel surface conditions (dry enamel, saliva or water contaminated enamel). The specimens were submitted to thermocycling prior to the shear bond strength test. RESULTS High shear bond strength mean values were obtained with the classic technique for dry enamel (31.47 MPa), statistically similar values were obtained when the sealant was combined with a self-etching water-based adhesive, in dry enamel (32.36 MPa), and when the sealant was combined with a self-etching water-based adhesive in water contaminated enamel (32.62 MPa). Under enamel salivary contamination, the best results were achieved using a water-based adhesive (24.78 MPa). CONCLUSIONS In saliva contaminated enamel, the combination of a sealant with a water-based self-etching adhesive can maintain high and satisfactory values of bond strength.
Collapse
|
230
|
Shear bond strength and interface analysis between a resin composite and a recent high-viscous glass ionomer cement bonded with various adhesive systems. Clin Oral Investig 2018; 23:2599-2608. [PMID: 30317399 DOI: 10.1007/s00784-018-2678-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Accepted: 10/01/2018] [Indexed: 10/28/2022]
Abstract
OBJECTIVE This study investigated the shear bond strength (SBS) and interface between a resin composite and a new high-viscous glass ionomer cement (HV-GIC), a HV-GIC, a resin-modified glass ionomer cement (RM-GIC), a bulk-fill flowable composite, and a regular flowable composite bonded with various adhesive systems. METHODS AND MATERIALS A resin composite (Filtek Z350) was bonded to a new HV-GIC (EQUIA Forte Fil) using various adhesive systems, including a universal adhesive in self-etch and etch-and-rinse mode (Scotchbond Universal), a two-step etch-and-rinse adhesive (Scotchbond 1-XT), a one-step self-etch adhesive (Optibond All-in-one) tested also after silane application (Monobond Plus), and a coating material (EQUIA Forte Coat). The resin composite was also bonded to a HV-GIC (Fuji IX GP), a RM-GIC (Fuji II LC), a bulk-fill flowable composite (SDR), and a regular flowable composite (Tetric Evo Flow) with the universal adhesive in self-etch mode (Scotchbond Universal). Two-way ANOVA followed by Dunnett's post hoc test was used to investigate the difference in SBS. Failures were analyzed by chi-square test. Bonding interfaces were examined by environmental scanning electron microscopy (E-SEM). RESULTS SBS to EQUIA Forte Fil was significantly lower with Scotchbond 1-XT than with all other adhesive systems. By using Scotchbond Universal with the self-etch technique, the SBS to EQUIA Forte Fil was significantly higher than the SBS to Fuji IX GP and significantly lower than the SBS to Fuji II LC, SDR, and Tetric Evo Flow. E-SEM images showed an intimate contact at all interfaces examined. CONCLUSION EQUIA Forte Fil showed satisfactory SBS and interfaces with all adhesives tested. CLINICAL RELEVANCE Bonding between the resin composite and HV-GIC can be achieved using a universal adhesive in self-etch mode, an easy-to-use adhesive system.
Collapse
|
231
|
Phaneuf M, Haimeur A, França R. Effect of anaerobic cure of self-etch adhesive on degree of conversion and shear bond strength. Clin Oral Investig 2018; 23:2227-2233. [PMID: 30284101 DOI: 10.1007/s00784-018-2645-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2016] [Accepted: 09/20/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The main aim was to evaluate the effect of postponing the curing of the adhesive layer until the first layer of composite resin is applied-hereby oxygen-inhibited layer (OIL) formation and its detrimental effect on the degree of conversion (DC) of self-etch adhesives should be prevented. For this purpose, the degree of conversion and shear bond strength of four current market self-etch adhesives were evaluated, assessing the effect of curing the adhesives anaerobically and then under two different thicknesses of composite resin, and compare this to the samples cured alone and in air. MATERIALS AND METHODS The degrees of conversion were obtained by attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, after the samples were prepared on a glass slide. The samples were either light-cured in air or anaerobically under a clear matrix strip alone, under 2 mm of cured composite resin or under 4 mm of cured composite resin. To determine the shear bond strength (SBS), extracted molars were halved and set in acrylic. Prefabricated cured cylinders of composite resin (TPH 3, 2.4 mm in diameter) of two different lengths are placed over the adhesives under the following conditions: light-cured conventionally (2-mm-long cylinder) and light-cured anaerobically under the uncured end of the piece of composite resin (using both 2- and 4-mm-long cylinders as separate treatments). After another incubation for 24 h at 37 °C, the samples were subjected to shearing using the Bisco Shear Bond Strength Tester. RESULTS The degree of conversion of the one-step self-etch adhesives was not statistically different when cured anaerobically under a clear matrix strip or cured anaerobically under 2 mm of composite resin. These results were greater than those cured under 4 mm. Shear bond strength between samples cured in air and anaerobically were similar under 2 mm of composite resin tubes, while those cured anaerobically under 4 mm of resin showed lower shear bond strength. CONCLUSION When cured anaerobically, one-step self-etch adhesives show a greater degree of conversion and no significant difference in degree of conversion and shear bond strength when compared to those cured in air under the same thickness of composite resin. CLINICAL RELEVANCE The results obtained from DC and SBS analysis show promise in placing the uncured adhesive under the composite resin and curing both the adhesive and restoration material simultaneously.
Collapse
|
232
|
Tsuka H, Morita K, Kato K, Kimura H, Abekura H, Hirata I, Kato K, Tsuga K. Effect of laser groove treatment on shear bond strength of resin-based luting agent to polyetheretherketone (PEEK). J Prosthodont Res 2018; 63:52-57. [PMID: 30220621 DOI: 10.1016/j.jpor.2018.08.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 08/03/2018] [Accepted: 08/05/2018] [Indexed: 11/18/2022]
Abstract
PURPOSE The mechanical properties of polyetheretherketone (PEEK) are ideally suited for fixed dental prostheses. However, PEEK typically has low adhesion strength to resin-based luting agent. This study assessed the shear bond strength between laser groove treated PEEK and resin-based luting agent. METHODS A total of 230 specimens were randomly divided into five groups (n=46): no-treatment, air abrasion treatment, 100μm-deep, 150μm-deep, and 200μm-deep laser groove treatments. The surface roughness was measured, scanning electron microscopy was used to observe the specimen surfaces, and X-ray photoelectron spectroscopy (XPS) was used to analyze the surfaces. Each group was divided into four resin-based luting agent subgroups: Panavia V5, RelyX Ultimate Resin Cement, G-CEM Link Force, and Super-Bond C&B. After the resin-based luting agent was bonded to the specimens, the bond strength was measured using shear tests and the failure modes were assessed by stereomicroscopy. The surfaces were also observed by scanning electron microscopy (SEM) after the shear bond strength measurements. The data were statistically analyzed using a two-way analysis of variance and Tukey's honest significant difference test (α=0.05). RESULTS The PEEK surface after laser groove treatment groups exhibited the highest mean Ra values. In the XPS analysis, the laser treated PEEK surface exhibited an effective surface composition for bonding with resin-based luting agent. The shear bond strengths for the laser groove treated samples were significantly higher (p<0.05) than those of the no-treatment and air abrasion treatment groups. CONCLUSIONS The shear bond strength between PEEK and resin-based luting agent was substantially improved by laser groove treatment.
Collapse
|
233
|
Demirovic K, Slaj M, Spalj S, Slaj M, Kobaslija S. Comparison of Shear Bond Strength of Orthodontic Brackets Using Direct and Indirect Bonding Methods in Vitro and in Vivo. Acta Inform Med 2018; 26:125-129. [PMID: 30061785 PMCID: PMC6029916 DOI: 10.5455/aim.2018.26.125-129] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Aim: Aim of article was to compare the shear bond strength of indirectly and directly bonded orthodontic brackets. Materials and methods: The experimental in vitro study included 60 maxillary and mandibular premolars. Teeth were mounted on cold-cure acrylic blocks for each tooth separately and divided into two groups: directly bonded brackets (30 teeth) and indirectly bonded brackets (30 teeth). Brackets (Discovery, Roth 0.022”, Dentaurum, Ispringen, Germany) were bonded using Transbond XT (3M Unitek, Monrovia, CA, USA) in direct method, while in indirect technique, a combination of Transbond XT and Sondhi Rapid Set (3M Unitek, Monrovia, CA, USA) was used. The shear bond strength and adhesive remnant index (ARI) were evaluated. The in vivo study included 30 subjects - 15 with indirectly bonded brackets and 15 with directly bonded brackets. Survival rate was assessed during the period of 6 months. Results: No statistically significant difference in the shear bond strength was found in direct (7.48±1.61 MPa) and indirect labial bonding methods (7.8.2±1.61 MPa). Both methods produced very similar amount of adhesive remnant on tooth surface (median = 1; interquartile range 1–2). There were no significant differences in bracket survival rate between methods. Conclusion: Regarding the shear bond strength, adhesive remnant on tooth surface, and survival rate, both indirect and direct methods of orthodontic bracket bonding seem to be equally valuable methods in clinical practice.
Collapse
|
234
|
Bond strength of pre-coated flash-free adhesive ceramic brackets. An in vitro comparative study on the second mandibular premolars. Int Orthod 2018; 16:425-439. [PMID: 30006079 DOI: 10.1016/j.ortho.2018.06.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
CONTEXT/OBJECTIVES Clinical studies show a mean bond failure rate of orthodontic brackets, which ranges between 6% and 8%, with a predominance for the second mandibular premolars. The pre-coated flash-free adhesive ceramic brackets allow to obtain, according to their manufacturer, a low bond failure rate, while ensuring a simplified implementation. The aim of this study was to measure the shear bond strength of ceramic brackets bonded with the direct method using a pre-coated flash-free adhesive system, and to compare it with the shear bond strength of the old generation precoated brackets and that of operator coated brackets to the buccal surface of the second mandibular premolars. MATERIEL AND METHODS 45-second mandibular premolars extracted for orthodontic purposes were randomly distributed into 3 groups of 15 teeth each. In the first group, the brackets were precoated with the APC™ Flash-Free® system (3M Unitek; in the second group, with the APC Plus® system (3M Unitek), and in the third group, the brackets were bonded manually with the Transbond XT® composite (3M Unitek). The enamel surface was prepared in the same way for the 3 groups: etching using 36% orthophosphoric acid, followed by the application of the Transbond XT® primer adhesive (3M Unitek). Each sample was submitted to shear bond strength forces using a Universal Testing Machine LRX® (Lloyd Instruments LTD., Fareham, UK) in shear mode with a crosshead speed of 1.0mm/min. The bond strength values of the brackets were recorded in megapascals (MPa) for each tooth. The mean values were then compared using the one-way ANOVA test. RESULTS Although the mean shear bond strength value for the APC Flash-Free® group was lower than those of the two other groups, this difference was not statistically significant (P=0.276). CONCLUSION Given the experimental conditions of this in vitro study, the shear bond strength of the brackets precoated with the APC Flash-Free® system is comparable to the two other conventional systems.
Collapse
|
235
|
Paryab M, Sharifi S, Kharazifard MJ, Kumarci N. Cavity Preparation by Laser in Primary Teeth: Effect of 2 Levels of Energy Output on the Shear Bond Strength of Composite Restoration to Dentin. J Lasers Med Sci 2018; 10:235-240. [PMID: 31749952 DOI: 10.15171/jlms.2019.38] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: One of the main applications of laser in dentistry is the removal of dental caries and preparation of restorative cavities. The morphology and wettability of laser prepared surfaces are different from that of those prepared with conventional method which may affect the quality of the adhesive potential of bonding agents in these surfaces. This study aimed to assess the shear bond strength of a total-etch and self-etch adhesive system to primary tooth dentin prepared by two different energy densities of Er:YAG laser in comparison with surfaces prepared by bur. Methods: A total of 60 human primary second molars extracted for orthodontic purposes were selected and randomly divided into 3 main groups of equal (n=20). Group A: Preparation of dentin surface by bur; group B: Preparation of dentin surface by laser with 300 mJ energy level; group C: Preparation of dentin surface by laser with 400 mJ energy level. In each of the main groups, the teeth were randomly assigned to 2 subgroups. Composite resin material was bonded with the total-etch adhesive system in subgroups A1, B1, and C1 and with the self-etch adhesive system in subgroups A2, B2, and C2. The samples were thermo-cycled, and composite restorations shear bond strength was measured in MPa. Data were analyzed using two-way analysis of variance (ANOVA), and P values less than 0.05 were considered statistically significant. Results: The highest and the lowest shear bond strength values were observed in group A2 (Preparation by bur- Composite resin material bonded by Clearfil SE Bond) and group C2 (Preparation by laser with 400 mJ energy level - Composite resin material bonded by Clearfil SE Bond), respectively. The results showed no statistically significant differences between the study subgroups (P > 0.05). Conclusion: It is concluded that in terms of shear bond strength to dentin, Single Bond and Clearfil SE Bond adhesive agents adequately perform in primary tooth dentin prepared by Er: YAG laser with energy levels of 300 and 400 mJ and frequency of 10 Hz.
Collapse
|
236
|
Mirhashemi A, Chiniforush N, Jadidi H, Sharifi N. Comparative study of the effect of Er:YAG and Er:Cr;YSGG lasers on porcelain: etching for the bonding of orthodontic brackets. Lasers Med Sci 2018; 33:1997-2005. [PMID: 29980947 DOI: 10.1007/s10103-018-2573-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Accepted: 06/27/2018] [Indexed: 10/28/2022]
Abstract
This study investigated the effect of Er:YAG (smart 2940 Dplus, DEKA, Italy) and Er:CrYSGG (Waterlase iPlus, Biolase, USA) lasers on the shear bond strength (SBS) between the orthodontic brackets and dental porcelain in comparison with conventional acid etching with 9% hydrofluoric acid (HF, Ultradent, USA). A total of 60 specimens of maxillary incisor crown were prepared and randomly assigned to five groups; each group was subjected to a different porcelain surface conditioning: (1) etching with the 9% HF for 2 min; (2) etching with the 9% HF for 2 min followed by irradiation with the Er:CrYSGG laser (3-W power, 10-Hz frequency for 10 s); (3) etching with the 9% HF for 2 min followed by irradiation with the Er:YAG laser (3-W power, 10-Hz frequency for 10 s); (4) Irradiation with the Er:CrYSGG laser (3-W power, 10-Hz frequency for 10 s without acid etching) and (5) irradiation with the Er:YAG laser (3-W power,10-Hz frequency for 10 s without acid etching). After using Transbond XT primer and Transbond XT adhesive, the metal brackets (Dentaurum, Germany equilibrium 2, optimal design) bonded to the conditioned porcelain surface. Subsequently, the specimens were thermocycled for 5000 cycles and then debonded using the Universal Testing Machine (Zwick). In each group, one specimen was not bonded to brackets to allow further examination with electron microscopy. After debonding, the specimens were examined by stereomicroscope to determine their adhesive remnant index (ARI). The average SBS [Mean (SD)] values in the five groups were as follows: HF (32.58 ± 9.21 MPa), Er:CrYSGG + HF (27.81 ± 7.66 MPa), Er:YAG + HF (23.08 ± 9.55 MPa), Er:CrYSGG (14.11 ± 9.35 MPa), and Er:YAG (6.30 ± 3.09 MPa). A statistically significant difference in SBS existed between the first three groups and the two laser groups (df = 4, F = 18.555, p < 0.001). Evaluation of ARI values showed that bond failures in the first three groups were mostly of cohesive and mixed types, but in the laser groups, they were mostly adhesive. Chi-square was not significant between groups (p = 0.219). The Er:YAG laser with the stated specifications is not a suitable alternative to HF etching. In the case of Er:CrYSGG laser, although the conditioning outcome met the bond strength requirement for orthodontic brackets (that is, 6-8 MPa). Therefore, the bond strength must be further improved by fine-tuning the irradiation details.
Collapse
|
237
|
Influence of different low-pressure plasma process parameters on shear bond strength between veneering composites and PEEK materials. Dent Mater 2018; 34:e246-e254. [PMID: 29935768 DOI: 10.1016/j.dental.2018.06.004] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Revised: 03/27/2018] [Accepted: 06/06/2018] [Indexed: 11/21/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the impact of oxygen and argon/oxygen low-pressure plasma on the shear bond strength (SBS) between dental PEEK compounds and veneering composites as a function of plasma process time. METHODS Of an unfilled PEEK ("Juvora") and two pigment powder filled PEEK compounds ("DC4420", "DC4450"), 273 rectangular plates were prepared and polished up to 1200 grit. Afterwards the samples were sandblasted and randomly assigned to five different surface pre-treatment groups (1. No plasma (control); 2. O2 plasma for 3min; 3. O2 plasma for 35min; 4. Ar/O2 plasma for 3min; 5. Ar/O2 plasma for 35min). Surface roughness and water contact angles were recorded using three samples of each PEEK compound for each of the plasma treatment groups. An adhesive (visio.link, Bredent GmbH & Co KG, Senden, Germany) was applied onto the specimen surfaces and light cured. A mold was used to shape three different veneering composites (a) Vita VM LC, "Vita" (Vita Zahnfabrik, Bad Säckingen, Germany); (b) GC GRADIA, "Gradia" (GC Europe, Leuven, Belgium); (c) GC GRADIA DIRECT Flo, "Gradia Flo" (GC Europe, Leuven, Belgium)) into a cylindrical form on the sample surface before light curing. SBS was measured using a universal testing machine after 24h of incubation in distilled water at 37°C. RESULTS The two pigment filled PEEK compounds treated with O2 plasma and veneered with Gradia Flo showed the highest SBS values (34.92±6.55MPa and 34.2±1.87MPa) followed by the combination of the unfilled PEEK material with Gradia Flo (29.57±3.71MPa). The SBS values of the samples veneered with Gradia were lower, but not significantly so. The SBS values of the specimens with Vita were for the most part associated with significantly lower results. SIGNIFICANCE A low-pressure plasma process using oxygen plasma for a duration of 35min, preceded by sandblasting, seems to be the most effective in increasing shear bond strength between veneering composites and PEEK materials.
Collapse
|
238
|
In vitro comparison of an Er:YAG laser-activated bleaching system with different light-activated bleaching systems for color change, surface roughness, and enamel bond strength. Lasers Med Sci 2018; 33:1913-1918. [PMID: 29860663 DOI: 10.1007/s10103-018-2555-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 05/28/2018] [Indexed: 10/14/2022]
Abstract
To compare an Er:YAG laser-activated bleaching system with different light-activated in-office bleaching systems for color change, surface roughness, and post-bleaching enamel bond strength. 51 enamel slabs were prepared from the sound buccal enamel of extracted bovine teeth. The teeth were randomly divided into three groups according to different light-activated office bleaching systems (n = 17): diode laser (Epic, Biolase) (940 nm, 7 W, continuous mode), Er:YAG laser (LightWalker, Fotona) (2940 nm, 50 mJ, 10 Hz, 1000 μs), and LED (Radii Plus) (440-480 nm, 1500 mW/cm2). All systems were used with their compatible bleaching agents according to manufacturers' recommendations. The tooth color and surface roughness (Ra) were assessed at baseline and after bleaching using a spectrophotometer and a surface profilometer, respectively. The color change was determined by the CIE L*a*b* system (ΔE, ΔL*, Δa*, Δb*). Kruskal-Wallis test was used for color change whereas Kruskal-Wallis and Wilcoxon tests were used to analyze the roughness data. For shear bond strength test (SBS), composite cylinders were bonded on bleached enamel samples 14 days after bleaching procedures and stored in water (37 °C). Specimens were then debonded with a universal testing machine at 1 mm/min and data were analyzed by using Kruskal-Wallis test. All the tested bleaching systems were effective on color change (ΔE > 3.3) and produced similar color change (p > 0.05). There were no significant differences among the Ra values of the groups neither at baseline nor after bleaching (p > 0.05). However, comparing the baseline and after bleaching Ra values, a significant increase was observed for all tested groups (p < 0.05). Significant differences were also found among all systems for SBS (p < 0.05). The highest values were obtained in Er:YAG group, whereas the LED group revealed the lowest values (p < 0.05). All tested bleaching systems were effective on tooth whitening, whereas they all led to an increase on surface roughness. Although the current Er:YAG laser-activated bleaching system did not differ from other tested bleaching systems according to color change and surface roughness, it appears to provide better results in terms of SBS.
Collapse
|
239
|
Promoting porcelain-zirconia bonding using different atmospheric pressure gas plasmas. Dent Mater 2018; 34:1188-1198. [PMID: 29784462 DOI: 10.1016/j.dental.2018.05.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 03/24/2018] [Accepted: 05/02/2018] [Indexed: 11/21/2022]
Abstract
OBJECTIVES To evaluate the effects of different atmospheric-pressure plasma (APP) on the physicochemical properties of yttria-stabilized zirconia, and promoting the adhesion of veneering porcelain. METHODS Cercon base zirconia disks were prepared to receive different treatments: as-polished, three APPs (oxygen, OP; argon, AP; and CF4, CP), and grit-blasted (GB). Their surface roughness and hydrophilicity were measured, and surface morphology was examined either after treatments, after simulated porcelain firing, or additional thermal etching. X-ray photoelectron spectroscopy (XPS) analysis characterized the surface chemical compositions. Shear bond strength (SBS) tests examined the adhesion between veneering porcelain and zirconia either before or after thermocycling. The layered ceramic disks were also sectioned to inspect the porcelain-zirconia interfaces. Statistical analysis was performed with one-way ANOVA and post hoc Duncan's test. RESULTS Grit-blasting caused surface damage and increased roughness. All APP-treated disks exhibited deeper grain boundaries and enlarged grain sizes after thermal etching, while CP disks revealed additional particle dispersions. Three APPs rendered the zirconia surface superhydrophilic. XPS spectra of three APP groups revealed increased hydroxyl groups and reduced C-C contents, and CP group especially showed the existence of Z-F bonds. CP exhibited the highest SBS both before and after thermocycling, while AP and GB also showed improved SBSs compared to the as-polished. OP presented reduced SBS, and its cross-sections showed increased microporosities in the veneering porcelain. SIGNIFICANCE APP did not change surface morphology but enhanced wettability. CP and AP improved porcelain-zirconia SBSs, primarily through surface hydroxylation. OP induced the microporosities in porcelain and adversely affected the adhesion.
Collapse
|
240
|
Effect of two-step and one-step surface conditioning of glass ceramic on adhesion strength of orthodontic bracket and effect of thermo-cycling on adhesion strength. J Mech Behav Biomed Mater 2018; 84:22-27. [PMID: 29729577 DOI: 10.1016/j.jmbbm.2018.04.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 04/16/2018] [Accepted: 04/23/2018] [Indexed: 11/22/2022]
Abstract
PURPOSE The adhesion strength of orthodontic brackets bonded to dental glass ceramics was evaluated after ceramic surface was treated with two-step and one-step surface conditioning systems, and subjecting to thermo-cycling. MATERIALS AND METHOD A total of forty specimens were fabricated from silica based glass ceramic (lithium disilicate) by duplicating the buccal surface of maxillary first premolar. The specimens were randomly assigned to two experimental groups (n = 20), group one specimens were treated with two-step surface conditioning system (IPS ceramic etching gel™ and Monobond plus™) and group two specimens were treated with one-step surface conditioning system (Monobond etch and prime™). The surface roughness of the specimens after treatment with two-step and one-step surface conditioning system was measured using non-contact surface profilometer. Ten randomly selected specimens from each group were subjected to thermo-cycling and the remaining ten served as baseline. The shear bond strength of the specimens was measured using universal material testing machine. The adhesive remnant index score was calculated, and the results of surface roughness and bond strength were tabulated and subjected to analysis of variance and post hoc tukey's test at a significance level of p < 0.05. RESULTS The results of the study showed that the specimens treated with two-step conditioning system had higher surface roughness and bond strength than one-step conditioning system. The majority of the specimens treated with both two-step and one-step conditioned specimens showed adhesive failure after subjecting thermo-cycling. CONCLUSIONS Traditional two-step conditioning provides better bond strength. The clinical importance of the study is that, the silane promoted adhesion significantly reduces on exposure to thermo-cycling.
Collapse
|
241
|
Kilinç DD, Sayar G. The effect of prior sandblasting of the wire on the shear bond strength of two different types of lingual retainers. Int Orthod 2018; 16:294-303. [PMID: 29631817 DOI: 10.1016/j.ortho.2018.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE The aim of this study was to evaluate the effect of total surface sandblasting on the shear bond strength of two different retainer wires. The null hypothesis was that there is no difference in the bond strength of the two types of lingual retainer wires when they are sandblasted. MATERIALS AND METHODS One hundred and sixty human premolar teeth were equally divided into four groups (n=40). A pair of teeth was embedded in self-curing acrylic resin and polished. Retainer wires were applied on the etched and rinsed surfaces of the teeth. Four retainers were used: group 1: braided retainer (0.010×0.028″, Ortho Technology); group 2: sandblasted braided retainer (0.010×0.028″, Ortho Technology); group 3: coaxial retainer (0.0215″ Coaxial, 3M) and group 4: sandblasted coaxial retainer (0.0215″ Coaxial, 3M). The specimens were tested using a universal test machine in shear mode with a crosshead speed of one mm/min. RESULTS One-way analysis of variance (Anova) was used to determine the significant differences among the groups. There was no significant difference (P=0.117) among the groups according to this test. CONCLUSIONS The null hypothesis was accepted. There was no statistically significant difference among the shear bond strength values of the four groups.
Collapse
|
242
|
Gamal AE, Medioni E, Rocca JP, Fornaini C, Brulat-Bouchard N. CO 2 laser dentin surface treatment most effectively increased ceramic shear bond strength. Laser Ther 2018; 27:48-54. [PMID: 29795971 PMCID: PMC5958235 DOI: 10.5978/islsm.18-or-05] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2017] [Accepted: 11/16/2017] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND AIMS The purpose of this study is to determine the effect of CO2 laser irradiation in comparison with sandblasting (Sb), hydrofluoric acid (Hf) and silane coupling agent (Si) on shear bond strength (SBS) of resin cement to CAD/CAM ceramics bonded to dentin. MATERIAL AND METHODS Forty-eight (CAD/CAM) ceramic discs were prepared and grouped by material, i.e. lithium disilicate (Emax CAD) and zirconia ceramic (Emax ZirCAD), distributed into four different groups: group A, lithium disilicate (Li) CO2/HF/Si; group B, Li: HF/Si; group C, zirconia (Zr) CO2/Sb/Si; group D, Zr: Sb/Si. RESULTS It was shown significant difference between irradiated and non-irradiated groups in terms of shear bond strength for zirconia ceramics (p value = 0.039). CONCLUSION CO2 laser irradiation increases shear bond strength for both CAD/CAM ceramics bonded to dentin.
Collapse
|
243
|
Al-Makramani BMA, Razak AAA, Abu-Hassan MI, Al-Sanabani FA, Albakri FM. Effect of Luting Cements On the Bond Strength to Turkom-Cera All-Ceramic Material. Open Access Maced J Med Sci 2018; 6:548-553. [PMID: 29610618 PMCID: PMC5874383 DOI: 10.3889/oamjms.2018.111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 02/05/2018] [Accepted: 02/07/2018] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations. AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material. MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test. RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05). CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.
Collapse
|
244
|
Henriques B, Fabris D, Souza JCM, Silva FS, Carvalho Ó, Fredel MC, Mesquita-Guimarães J. Bond strength enhancement of zirconia-porcelain interfaces via Nd:YAG laser surface structuring. J Mech Behav Biomed Mater 2018. [PMID: 29524754 DOI: 10.1016/j.jmbbm.2018.02.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the effect of laser surface structuring on the bond strength of feldspar-based porcelain to zirconia, as compared to conventional sandblasting treatment. MATERIALS AND METHODS Thirty cylindrical zirconia substrates, previously sintered, were divided in three groups according to the type of surface conditioning: 1) sandblasting with 50 µm Al2O3; 2) laser structuring (Ø25 µm holes); and 3) laser structuring (Ø50 µm holes). Porcelain was injected onto the zirconia substrates. X-ray diffractometry (XRD) was used to evaluate the influence of the laser treatment on zirconia crystallographic phases. Shear bond strength test was performed. Micrographs using SEM were used to evaluate the zirconia surface after each surface treatment and to evaluate the fracture surface after the shear test. RESULTS The laser-structured groups presented the highest shear bond strength (65 ± 16 MPa and 65 ± 11 MPa, for the 25 µm and 50 µm holes, respectively). The sandblasting samples presented shear bond strength of 37 ± 16 MPa. XRD analysis showed that there was no phase transformation on the thermally affected surface due to laser action. Microcracks were created at some holes due to the high temperature gradient generated by laser. SIGNIFICANCE Laser structuring significantly increased (up to 75%) the shear bond strength of zirconia to veneering porcelain as compared to conventional sandblasting treatment. Therefore, laser structuring arises as a surface conditioning method for producing stronger and long lasting zirconia-porcelain interfaces.
Collapse
|
245
|
Zhang L, Sun H, Yu J, Yang H, Song F, Huang C. Application of electrophoretic deposition to occlude dentinal tubules in vitro. J Dent 2018; 71:43-48. [PMID: 29391182 DOI: 10.1016/j.jdent.2018.01.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 01/21/2018] [Accepted: 01/26/2018] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES This study aims to apply electrophoretic deposition (EPD) for occlusion of dentinal tubules in vitro and investigate its effect on tubule occlusion and shear bond strength (SBS). METHODS Charged mesoporous silica nanoparticles (MSNs) were synthesized and characterized through field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), dynamic light scattering (DLS), and Fourier transform infrared (FT-IR) spectroscopy analyses. Thirty-nine sensitive dentin specimens were modeled and assigned randomly to three groups with different treatments (n = 13 each): group 1, immersion in the MSN suspension; and groups 2 and 3, anodic EPD with the specimen on the negative and positive electrode respectively. The effect of dentinal tubule occlusion was evaluated by dentin permeability test (n = 10 each) and FESEM examination (n = 3 each). Moreover, 18 specimens were grouped (n = 6 each) and treated in the same method. A resin stick was bonded onto each of the specimen using a self-etch adhesive (single bond universal) for SBS testing. RESULTS Negatively-charged MSNs were synthesized and characterized as small and well-dispersed particles. After the EPD treatment (group 3), the dentinal tubules were effectively occluded by MSNs, which infiltrated into the tubules at a depth of approximately 7-8 μm and tightly associated with the tubular inwalls. SBS was not significantly different among the three groups (P > 0.05). CONCLUSIONS Synthesized MSNs were deposited into dentinal tubules by EPD treatment without compromising dentin bond strength. CLINICAL SIGNIFICANCE Application of EPD is a new approach for occlusion of dentinal tubules and exhibits potential in the study of dentin hypersensitivity.
Collapse
|
246
|
Mirhashemi AH, Chiniforush N, Sharifi N, Hosseini AM. Comparative efficacy of Er,Cr:YSGG and Er:YAG lasers for etching of composite for orthodontic bracket bonding. Lasers Med Sci 2018; 33:835-841. [PMID: 29327089 DOI: 10.1007/s10103-017-2417-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Accepted: 12/07/2017] [Indexed: 10/18/2022]
Abstract
Several techniques have been proposed to obtain a durable bond, and the efficacy of these techniques is assessed by measuring parameters such as bond strength. Laser has provided a bond strength as high as that of acid etching in vitro and has simpler use with shorter clinical time compared to acid etching. This study aimed to compare the efficacy of Er:YAG and Er,Cr:YSGG lasers for etching and bonding of composite to orthodontic brackets. No previous study has evaluated the effect of these particular types of laser. A total of 70 composite blocks were randomly divided into five groups (n = 14): group 1, etching with phosphoric acid for 20 s; group 2, Er:YAG laser irradiation with 2 W power for 10 s; group 3, Er:YAG laser with 3 W power for 10 s; group 4, Er,Cr:YSGG laser with 2 W power for 10 s; group 5, Er,Cr:YSGG laser with 3 W power for 10 s. Metal brackets were then bonded to composites, and after 5000 thermal cycles, they were subjected to shear bond strength test in a universal testing machine after 24 h of water storage. One sample of each group was evaluated under a scanning electron microscope (SEM) to assess changes in composite surface after etching. The adhesive remnant index (ARI) was calculated under a stereomicroscope. Data were statistically analyzed. The mean and standard deviation of shear bond strength were 18.65 ± 3.36, 19.68 ± 5.34, 21.31 ± 4.03, 17.38 ± 6.94, and 16.45 ± 4.26 MPa in groups 1-5, respectively. The ARI scores showed that the bond failure mode in all groups was mainly mixed. The groups were not significantly different in terms of shear bond strength. Er:YAG and Er,Cr:YSGG lasers with the mentioned parameters yield optimal shear bond strength and can be used as an alternative to acid etching for bracket bond to composite.
Collapse
|
247
|
Kiomarsi N, Arjmand Y, Kharrazi Fard MJ, Chiniforush N. Effects of Erbium Family Laser on Shear Bond Strength of Composite to Dentin After Internal Bleaching. J Lasers Med Sci 2017; 9:58-62. [PMID: 29399313 DOI: 10.15171/jlms.2018.12] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: The aim of this study was to assess the effect of surface treatment with erbium: yttrium-aluminum-garnet (Er:YAG) and erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers on shear bond strength of composite resin to recently bleached dentin. Methods: In this study, 40 extracted human premolars were selected. The teeth were cut 4 mm apical to the cusp tip and were randomly divided into four groups (n=10 in each group) for shear bond strength testing. For bleaching, 35% hydrogen peroxide (H2 o2 ) gel (Opalescence Endo, Ultradent, South Jordan, UT, USA) was applied to dentin surfaces of all specimens for 10 days. Before etching and bonding, in Er,Cr:YSGG and Er:YAG laser groups, dentin surfaces were irradiated with Er,Cr:YSGG and Er:YAG lasers, respectively. In Er,Cr:YSGG group, Er:YAG group and control group, composite restoration was performed immediately after bleaching while in common procedure group, composite restoration was performed after seven days. The teeth were then subjected to shear bond strength testing machine. The data were statistically analyzed using analysis of variance (ANOVA) and Tukey test. Results: The mean and standard deviation (SD) of shear bond strength was 4.3 ± 1.4 MPa for control group, 6.7 ± 2.0 Mpa for Er,Cr:YSGG group, 14.4 ± 3.7 Mpa for Er:YAG group and 19.4 ± 2.6 Mpa for common procedure group. Conclusion: The shear strength of composite to Er:YAG laser-treated bleached dentin was significantly higher than control group while significantly lower than common procedure.
Collapse
|
248
|
Lee KS, Shin MS, Lee JY, Ryu JJ, Shin SW. Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials. J Adv Prosthodont 2017; 9:350-357. [PMID: 29142642 PMCID: PMC5673611 DOI: 10.4047/jap.2017.9.5.350] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Revised: 02/08/2017] [Accepted: 03/21/2017] [Indexed: 11/17/2022] Open
Abstract
PURPOSE The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials. MATERIALS AND METHODS One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with 50 µm alumina, and airborne abrasion with 110 µm silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond). After surface treatment, surface roughness and contact angles were examined. Topography modifications after surface treatment were assessed with scanning electron microscopy. Resin composite was mounted on each specimen and then subjected to shear bond strength (SBS) test. SBS data were analyzed statistically using two-way ANOVA, and post-hoc Tukey's test (P<.05). RESULTS Regardless of bonding materials, mechanical surface treatment groups yielded significantly higher shear bonding strength values than chemical surface treatment groups. Unlike other adhesives, MDP and silane containing self-etching universal adhesive (Single Bond Universal) showed an effective shear bonding strength regardless of surface treatment method. CONCLUSION Mechanical surface treatment behaves better in terms of PEKK bonding. In addition, self-etching universal adhesive (Single Bond Universal) can be an alternative bonding material to PEKK irrespective of surface treatment method.
Collapse
|
249
|
Rechmann P, Bartolome N, Kinsel R, Vaderhobli R, Rechmann BMT. Bond strength of etch-and-rinse and self-etch adhesive systems to enamel and dentin irradiated with a novel CO 2 9.3 μm short-pulsed laser for dental restorative procedures. Lasers Med Sci 2017; 32:1981-1993. [PMID: 28812169 DOI: 10.1007/s10103-017-2302-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Accepted: 08/03/2017] [Indexed: 10/19/2022]
Abstract
The objective of this study was to evaluate the influence of CO2 9.3 μm short-pulsed laser irradiation on the shear bond strength of composite resin to enamel and dentin. Two hundred enamel and 210 dentin samples were irradiated with a 9.3 µm carbon dioxide laser (Solea, Convergent Dental, Inc., Natick, MA) with energies which either enhanced caries resistance or were effective for ablation. OptiBond Solo Plus [OptiBondTE] (Kerr Corporation, Orange, CA) and Peak Universal Bond light-cured adhesive [PeakTE] (Ultradent Products, South Jordan, UT) were used. In addition, Scotchbond Universal [ScotchbondSE] (3M ESPE, St. Paul, MN) and Peak SE self-etching primer with Peak Universal Bond light-cured adhesive [PeakSE] (Ultradent Products) were tested. Clearfil APX (Kuraray, New York, NY) was bonded to the samples. After 24 h, a single plane shear bond test was performed. Using the caries preventive setting on enamel resulted in increased shear bond strength for all bonding agents except for self-etch PeakSE. The highest overall bond strength was seen with PeakTE (41.29 ± 6.04 MPa). Etch-and-rinse systems achieved higher bond strength values to ablated enamel than the self-etch systems did. PeakTE showed the highest shear bond strength with 35.22 ± 4.40 MPa. OptiBondTE reached 93.8% of its control value. The self-etch system PeakSE presented significantly lower bond strength. The shear bond strength to dentin ranged between 19.15 ± 3.49 MPa for OptiBondTE and 43.94 ± 6.47 MPa for PeakSE. Etch-and-rinse systems had consistently higher bond strength to CO2 9.3 µm laser-ablated enamel. Using the maximum recommended energy for dentin ablation, the self-etch system PeakSE reached the highest bond strength (43.9 ± 6.5 MPa).
Collapse
|
250
|
Godard M, Deuve B, Lopez I, Hippolyte MP, Barthélemi S. Shear bond strength of two 2-step etch-and-rinse adhesives when bonding ceramic brackets to bovine enamel. Int Orthod 2017; 15:388-404. [PMID: 28755867 DOI: 10.1016/j.ortho.2017.06.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
AIM The present study assessed a fracture analysis and compared the shear bond strength (SBS) of two 2-step etch-and-rinse (E&R) adhesives when bonding ceramic orthodontic brackets to bovine enamel. MATERIALS AND METHODS Thirty healthy bovine mandibular incisors were selected and were equally and randomly assigned to 2 experimental groups. Ceramic brackets (FLI Signature Clear®, RMO) were bonded onto bovine enamel using an adhesive system. In group 1 (n=15), the conventional E&R adhesive (OrthoSolo®+Enlight®, Ormco) was used, and in group 2 (n=15), the new E&R adhesive limited to ceramic bracket bonding (FLI ceramic adhesive®: FLI sealant resin®+FLI adhesive paste®, RMO) was used. In order to obtain appropriate enamel surfaces, the vestibular surfaces of mandibular bovine incisors were flat ground. After bonding, all the samples were stored in distilled water at room temperature for 21 days and subsequently tested for SBS, using the Instron® universal testing machine. The Adhesive Remnant Index (ARI) scores were evaluated. Failure modes were assessed using optical microscopy at magnification ×40. A statistic data analysis was performed using the Mann-Whitney U-test (P<0.05). RESULTS The test showed a significant difference (P=0.00155) between the two groups for the SBS values. Group 1 had significantly higher SBS values (9.79 to 20.83MPa) than group 2 (8.45 to 13.94MPa). Analysis of the ARI scores revealed that most of the failures occurred at the enamel/adhesive interface. A statistically significant difference was found for the ARI scores between the two groups (P=0.00996). Only two fractured brackets, which remained bonded onto the bovine enamel, were reported. Both occurred in group 1. CONCLUSION When bonded to ceramic brackets, FLI ceramic adhesive® (RMO) was demonstrated to be very predictable and safe for clinical application in enamel bonding, whereas the results obtained with the conventional adhesive system (OrthoSolo®+Enlight®, Ormco) were less reproducible and revealed slightly excessive shear bond strength values.
Collapse
|