26
|
Koermendy D, Nietlispach F, Shakir S, Gloekler S, Wenaweser P, Windecker S, Khattab AA, Meier B. Amplatzer left atrial appendage occlusion through a patent foramen ovale. Catheter Cardiovasc Interv 2014; 84:1190-6. [DOI: 10.1002/ccd.25354] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Revised: 10/28/2013] [Accepted: 12/30/2013] [Indexed: 12/17/2022]
|
27
|
Abstract
Microembolic signals (MES) can be detected in many recipients of mechanical aortic valve prostheses by transcranial Doppler ultrasound. The nature and etiology of these MES have remained unclear for a long time. The solid and gaseous nature of MES are discussed, as well as whether or not MES may reflect artifacts. Recently, the gaseous nature of these MES has been widely established. To understand the physics of bubble formation related to mechanical heart valve prostheses, it is necessary to discuss the different types of cavitation occurring at the prostheses and the conditions leading to the degassing of blood. We describe the history of transcranial Doppler ultrasound-techniques and the current techniques in the measurement of these signals. Furthermore, the possible clinical impact of MES, as well as strategies for the design of new prostheses and surgical alternatives to diminish their load are discussed.
Collapse
|
28
|
O'Sullivan CJ, Stortecky S, Heg D, Pilgrim T, Hosek N, Buellesfeld L, Khattab AA, Nietlispach F, Moschovitis A, Zanchin T, Meier B, Windecker S, Wenaweser P. Clinical outcomes of patients with low-flow, low-gradient, severe aortic stenosis and either preserved or reduced ejection fraction undergoing transcatheter aortic valve implantation. Eur Heart J 2013; 34:3437-50. [DOI: 10.1093/eurheartj/eht408] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
29
|
Khattab AA, O'Sullivan CJ, Stefanini GG, Räber L, Paquin M, Windecker S, Meier B. New approach to direct stenting using a novel "all-in-one" coronary stent system via 5 French diagnostic catheters: a pilot study. Catheter Cardiovasc Interv 2013; 82:E403-10. [PMID: 23378279 DOI: 10.1002/ccd.24860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Revised: 01/22/2013] [Accepted: 01/27/2013] [Indexed: 11/06/2022]
Abstract
OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.
Collapse
|
30
|
Khattab AA, Stieger S, Kamat PJ, Vandenberghe S, Bongoni A, Stone GW, Seiler C, Meier B, Hess OM, Rieben R. Effect of pressure-controlled intermittent coronary sinus occlusion (PICSO) on myocardial ischaemia and reperfusion in a closed-chest porcine model. EUROINTERVENTION 2013; 9:398-406. [DOI: 10.4244/eijv9i3a63] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
31
|
Ruder TD, Ebert LC, Khattab AA, Rieben R, Thali MJ, Kamat P. Edema is a sign of early acute myocardial infarction on post-mortem magnetic resonance imaging. Forensic Sci Med Pathol 2013; 9:501-5. [DOI: 10.1007/s12024-013-9459-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/16/2013] [Indexed: 03/25/2023]
|
32
|
Nietlispach F, Gloekler S, Krause R, Shakir S, Schmid M, Khattab AA, Wenaweser P, Windecker S, Meier B. Amplatzer left atrial appendage occlusion: single center 10-year experience. Catheter Cardiovasc Interv 2013; 82:283-9. [PMID: 23412815 DOI: 10.1002/ccd.24872] [Citation(s) in RCA: 100] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2012] [Revised: 01/04/2013] [Accepted: 02/09/2013] [Indexed: 12/11/2022]
Abstract
OBJECTIVES To report a 10-year single center experience with Amplatzer devices for left atrial appendage (LAA) occlusion. BACKGROUND Intermediate-term outcome data following LAA occlusion are scarce. METHODS Short- and intermediate-term outcomes of patients who underwent LAA occlusion were assessed. All procedures were performed under local aesthesia without transesophageal echocardiography. Patients were discharged on acetylsalicylic acid and clopidogrel for 1-6 months. RESULTS LAA occlusion was attempted in 152 patients (105 males, age 72 ± 10 years, CHA2 DS2 -Vasc-score 3.4 ± 1.7, HAS-BLED-score 2.4 ± 1.2). Nondedicated devices were used in 32 patients (21%, ND group) and dedicated Amplatzer Cardiac Plugs were used in 120 patients (79%, ACP group). A patent foramen ovale or atrial septal defect was used for left atrial access and closed at the end of LAA occlusion in 40 patients. The short-term safety endpoints (procedural complications, bleeds) occurred in 15 (9.8%) and the efficacy endpoints (death, stroke, systemic embolization) in 0 patients. Device embolization occurred more frequently in the ND as compared to the ACP group (5 patients or 12% vs. 2 patients or 2%). Mean intermediate-term follow up of the study population was 32 months (range 1-120). Late deaths occurred in 15 patients (5 cardiovascular, 7 noncardiac, 3 unexplained). Neurologic events occurred in 2, peripheral embolism in 1, and major bleeding in 4 patients. The composite efficacy and safety endpoint occurred in 7% and 12% of patients. CONCLUSION LAA closure may be a good alternative to oral anticoagulation. This hypothesis needs to be tested in a randomized clinical trial to ensure that all potential biases of this observational study are accounted for.
Collapse
|
33
|
Meier B, Kalesan B, Mattle HP, Khattab AA, Hildick-Smith D, Dudek D, Andersen G, Ibrahim R, Schuler G, Walton AS, Wahl A, Windecker S, Jüni P. Percutaneous closure of patent foramen ovale in cryptogenic embolism. N Engl J Med 2013; 368:1083-91. [PMID: 23514285 DOI: 10.1056/nejmoa1211716] [Citation(s) in RCA: 597] [Impact Index Per Article: 54.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
BACKGROUND The options for secondary prevention of cryptogenic embolism in patients with patent foramen ovale are administration of antithrombotic medications or percutaneous closure of the patent foramen ovale. We investigated whether closure is superior to medical therapy. METHODS We performed a multicenter, superiority trial in 29 centers in Europe, Canada, Brazil, and Australia in which the assessors of end points were unaware of the study-group assignments. Patients with a patent foramen ovale and ischemic stroke, transient ischemic attack (TIA), or a peripheral thromboembolic event were randomly assigned to undergo closure of the patent foramen ovale with the Amplatzer PFO Occluder or to receive medical therapy. The primary end point was a composite of death, nonfatal stroke, TIA, or peripheral embolism. Analysis was performed on data for the intention-to-treat population. RESULTS The mean duration of follow-up was 4.1 years in the closure group and 4.0 years in the medical-therapy group. The primary end point occurred in 7 of the 204 patients (3.4%) in the closure group and in 11 of the 210 patients (5.2%) in the medical-therapy group (hazard ratio for closure vs. medical therapy, 0.63; 95% confidence interval [CI], 0.24 to 1.62; P=0.34). Nonfatal stroke occurred in 1 patient (0.5%) in the closure group and 5 patients (2.4%) in the medical-therapy group (hazard ratio, 0.20; 95% CI, 0.02 to 1.72; P=0.14), and TIA occurred in 5 patients (2.5%) and 7 patients (3.3%), respectively (hazard ratio, 0.71; 95% CI, 0.23 to 2.24; P=0.56). CONCLUSIONS Closure of a patent foramen ovale for secondary prevention of cryptogenic embolism did not result in a significant reduction in the risk of recurrent embolic events or death as compared with medical therapy. (Funded by St. Jude Medical; ClinicalTrials.gov number, NCT00166257.).
Collapse
|
34
|
Pilgrim T, Meier B, Khattab AA. Death by patent foramen ovale in a soccer player. THE JOURNAL OF INVASIVE CARDIOLOGY 2013; 25:162-164. [PMID: 23468450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A 34-year-old male patient was referred for primary percutaneous coronary intervention for ST-segment elevation myocardial infarction with cardiogenic shock and was found to have embolic left coronary artery occlusion and subsegmental pulmonary artery emboli as a consequence of venous thrombosis to trauma to the thigh in the presence of a patent foramen ovale.
Collapse
|
35
|
Stortecky S, Buellesfeld L, Wenaweser P, Heg D, Pilgrim T, Khattab AA, Gloekler S, Huber C, Nietlispach F, Meier B, Jüni P, Windecker S. Atrial fibrillation and aortic stenosis: impact on clinical outcomes among patients undergoing transcatheter aortic valve implantation. Circ Cardiovasc Interv 2013; 6:77-84. [PMID: 23386662 DOI: 10.1161/circinterventions.112.000124] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Atrial fibrillation (AF) is an important risk factor for stroke and is common among elderly patients undergoing transcatheter aortic valve implantation. The aim of this study was to assess the impact of AF on clinical outcomes among patients undergoing transcatheter aortic valve implantation. METHODS AND RESULTS Between August 2007 and October 2011, a total of 389 high-risk patients undergoing transcatheter aortic valve implantation were included into a prospective registry. AF was recorded in 131 patients (33.7%) with a mean CHA(2)DS(2)-VASC score of 4.5±1.2 and was paroxysmal in 26 (25.0%), persistent in 8 (7.7%), and permanent in 70 patients (67.3%). Patients with and without AF had similar baseline characteristics except for fewer revascularization procedures (coronary artery bypass grafting: 12% versus 22%; P=0.03) among AF patients. At 1 year, all-cause mortality was higher among patients with AF (30.9%) compared with those without AF (13.9%; hazard ratio [HR], 2.36; 95% confidence interval [CI], 1.43-3.90; P=0.0008). This was observed irrespective of the type of AF (permanent, HR, 2.47; 95% CI, 1.40-4.38; persistent, HR, 3.60; 95% CI, 1.10-11.78; paroxysmal, HR, 2.88; 95% CI, 1.37-6.05). Mortality gradually increased with higher CHA(2)DS(2)-VASC scores (score 1-3: HR, 2.20; 95% CI, 0.92-5.27; score 6-8: HR, 4.12; 95% CI, 2.07-8.20). The risks of stroke (3.9% versus 5.1%; HR, 0.76; 95% CI, 0.23-1.96; P=0.47) and life-threatening bleeding (19.8% versus 14.7%; HR, 1.37; 95% CI, 0.86-2.19; P=0.19) were similar among patients with and without AF. CONCLUSIONS AF is common among high-risk patients with severe aortic stenosis undergoing transcatheter aortic valve implantation and is associated with a >2-fold increased risk of all-cause and cardiovascular mortality, irrespective of the type of AF. The gradient of risk directly correlates with the CHA(2)DS(2)-VASC score.
Collapse
|
36
|
Stoller M, Traupe T, Khattab AA, de Marchi SF, Steck H, Seiler C. Effects of coronary sinus occlusion on myocardial ischaemia in humans: role of coronary collateral function. Heart 2013; 99:548-55. [DOI: 10.1136/heartjnl-2012-303305] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
|
37
|
Khattab AA, Meier B. Transcatheter left atrial appendage closure for stroke prevention among atrial fibrillation patients. Expert Rev Cardiovasc Ther 2013; 10:819-21. [PMID: 22908912 DOI: 10.1586/erc.12.70] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
38
|
Abdel-Wahab M, Richardt G, Joachim Büttner H, Toelg R, Geist V, Meinertz T, Schofer J, King L, Neumann FJ, Khattab AA. High-Speed Rotational Atherectomy Before Paclitaxel-Eluting Stent Implantation in Complex Calcified Coronary Lesions. JACC Cardiovasc Interv 2013; 6:10-9. [DOI: 10.1016/j.jcin.2012.07.017] [Citation(s) in RCA: 298] [Impact Index Per Article: 27.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2012] [Accepted: 07/04/2012] [Indexed: 12/13/2022]
|
39
|
Buellesfeld L, Stortecky S, Kalesan B, Gloekler S, Khattab AA, Nietlispach F, Delfine V, Huber C, Eberle B, Meier B, Wenaweser P, Windecker S. Aortic Root Dimensions Among Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv 2013; 6:72-83. [PMID: 23347864 DOI: 10.1016/j.jcin.2012.09.007] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2012] [Revised: 08/24/2012] [Accepted: 09/06/2012] [Indexed: 02/06/2023]
|
40
|
Pilgrim T, Kalesan B, Wenaweser P, Huber C, Stortecky S, Buellesfeld L, Khattab AA, Eberle B, Gloekler S, Gsponer T, Meier B, Jüni P, Carrel T, Windecker S. Predictors of Clinical Outcomes in Patients With Severe Aortic Stenosis Undergoing TAVI. Circ Cardiovasc Interv 2012; 5:856-61. [DOI: 10.1161/circinterventions.112.974899] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Background—
Patients with severe aortic stenosis at increased surgical risk continue to experience compromised long-term survival despite successful transcatheter aortic valve implantation. We used time-related pathways in a multistate analysis to identify predictors of adverse long-term outcome in patients who underwent transcatheter aortic valve implantation.
Methods and Results—
In a cohort of 389 patients with a mean age of 82.4±5.8 years and a STS score of 6.8±5.3 undergoing transcatheter aortic valve implantation between 2007 and 2011, multistate analysis was used to estimate mortality and stroke taking into account intercurrent events including kidney injury and the composite of access site and bleeding complications (ABC). Transapical access emerged as a predictor of kidney injury (hazard ratio [HR], 2.12; 95% confidence interval [CI] 1.00–4.47) and ABC (HR, 1.78; 95% CI, 1.07–2.96), but had no impact on the risk of stroke or death. Body mass index ≤20 kg/m
2
increased the risk of stroke or death (HR, 2.64; 95% CI, 1.25–5.54). Age >80 years (HR, 3.15; 95% CI, 1.11–8.92), body mass index ≤20 kg/m
2
(HR, 4.11; 95% CI, 1.33–12.70), prior stroke (HR, 16.42; 95% CI, 3.63–74.21), and presence of atrial fibrillation at baseline (HR, 4.12; 95% CI, 1.87–9.97) increased the risk of stroke and death after an intercurrent event of ABC.
Conclusions—
A body mass index ≤20 kg/m
2
was identified as a primary predictor of stroke and death after transcatheter aortic valve implantation during long-term follow-up, whereas transapical access emerged as a predictor of kidney injury and ABC. Age >80 years, body mass index ≤20 kg/m
2
, prior stroke, and presence of atrial fibrillation at baseline increased the risk of stroke and death after an intercurrent event of ABC.
Collapse
|
41
|
Stortecky S, Wenaweser P, Diehm N, Pilgrim T, Huber C, Rosskopf AB, Khattab AA, Buellesfeld L, Gloekler S, Eberle B, Schmidli J, Carrel T, Meier B, Windecker S. Percutaneous management of vascular complications in patients undergoing transcatheter aortic valve implantation. JACC Cardiovasc Interv 2012; 5:515-524. [PMID: 22625190 DOI: 10.1016/j.jcin.2012.01.021] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 12/02/2011] [Accepted: 01/11/2012] [Indexed: 12/29/2022]
Abstract
OBJECTIVES This study sought to investigate the feasibility and safety of percutaneous management of vascular complications after transcatheter aortic valve implantation (TAVI). BACKGROUND Vascular complications after TAVI are frequent and outcomes after percutaneous management of these adverse events not well established. METHODS Between August 2007 and July 2010, 149 patients underwent transfemoral TAVI using a percutaneous approach. We compared outcomes of patients undergoing percutaneous management of vascular complications with patients free from vascular complications and performed duplex ultrasonography, fluoroscopy, and multislice computed tomography during follow-up. RESULTS A total of 27 patients (18%) experienced vascular complications consisting of incomplete arteriotomy closure (n = 19, 70%), dissection (n = 3, 11%), arterial perforation (n = 3, 11%), arterial occlusion (n = 1, 4%), and pseudoaneurysm (n = 1, 4%). Percutaneous stent graft implantation was successful in 21 of 23 (91%) patients, whereas 2 patients were treated by manual compression, 2 patients underwent urgent surgery, and 2 patients required delayed surgery. Rates of major adverse cardiac events at 30 days were similar among patients undergoing percutaneous management of vascular complications and those without vascular complications (9% vs. 8%, p = 1.00). After a median follow-up of 10.9 months, imaging showed no evidence of hemodynamically significant stenosis (mean peak velocity ratio: 1.2 ± 0.4). Stent fractures were observed in 4 stents (22%, type I [6%], type II [16%]) and were clinically silent in all cases. CONCLUSIONS Vascular complications after TAVI can be treated percutaneously as a bailout procedure with a high rate of technical success, and clinical outcomes are comparable to patients without vascular complications. Stent patency is high during follow-up, although stent fractures require careful scrutiny.
Collapse
|
42
|
Guérios ÊE, Gloekler S, Pilgrim T, Stortecky S, Büllesfeld L, Khattab AA, Huber C, Meier B, Windecker S, Wenaweser P. Second valve implantation for the treatment of a malpositioned transcatheter aortic valve. THE JOURNAL OF INVASIVE CARDIOLOGY 2012; 24:457-462. [PMID: 22954566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
BACKGROUND Unfavorable immediate or delayed results after transcatheter aortic valve implantation (TAVI) may be a consequence of bioprosthesis malfunctioning, malpositioning, embolization, or degeneration. Deployment of a second valve within the first one implanted (TAVI-in-TAV) may be a potentially helpful therapeutic strategy. METHODS Six out of 412 patients undergoing TAVI had TAVI-in-TAV implantation for the treatment of a too high (n = 4) or too low position (n = 2) of the first implanted valve. RESULTS All TAVI-in-TAV procedures were successfully performed. The calculated valve area after second valve implantation was 1.6 ± 0.3 cm(2) with a mean gradient of 7.3 ± 2.2 mm Hg. Residual aortic regurgitation (AR) was mild in 5 patients and moderate in 1. At mid-term follow-up (30-724 days) neither the mean valve area (1.47 ± 0.31 cm(2)), the mean gradient (7.5 ± 3.6 mm Hg; 3.0-13.0 mm Hg) nor the degree of AR had changed significantly. CONCLUSION TAVI-in-TAV for correction of malpositioned or embolized valves is technically feasible and leads to favorable functional results during mid-term follow-up.
Collapse
|
43
|
Khattab K, Khattab AA, Ortak J, Richardt G, Bonnemeier H. Iyengar yoga increases cardiac parasympathetic nervous modulation among healthy yoga practitioners. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2012; 4:511-7. [PMID: 18227919 PMCID: PMC2176143 DOI: 10.1093/ecam/nem087] [Citation(s) in RCA: 93] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/22/2006] [Accepted: 04/23/2007] [Indexed: 11/19/2022]
Abstract
Relaxation techniques are established in managing of cardiac patients during rehabilitation aiming to reduce future adverse cardiac events. It has been hypothesized that relaxation-training programs may significantly improve cardiac autonomic nervous tone. However, this has not been proven for all available relaxation techniques. We tested this assumption by investigating cardiac vagal modulation during yoga.We examined 11 healthy yoga practitioners (7 women and 4 men, mean age: 43 ± 11; range: 26–58 years). Each individual was subjected to training units of 90 min once a week over five successive weeks. During two sessions, they practiced a yoga program developed for cardiac patients by B.K.S. Iyengar. On three sessions, they practiced a placebo program of relaxation. On each training day they underwent ambulatory 24 h Holter monitoring. The group of yoga practitioners was compared to a matched group of healthy individuals not practicing any relaxation techniques. Parameters of heart rate variability (HRV) were determined hourly by a blinded observer. Mean RR interval (interval between two R-waves of the ECG) was significantly higher during the time of yoga intervention compared to placebo and to control (P < 0.001 for both). The increase in HRV parameters was significantly higher during yoga exercise than during placebo and control especially for the parameters associated with vagal tone, i.e. mean standard deviation of NN (Normal Beat to Normal Beat of the ECG) intervals for all 5-min intervals (SDNNi, P < 0.001 for both) and root mean square successive difference (rMSSD, P < 0.01 for both). In conclusion, relaxation by yoga training is associated with a significant increase of cardiac vagal modulation. Since this method is easy to apply with no side effects, it could be a suitable intervention in cardiac rehabilitation programs.
Collapse
|
44
|
Brugger N, Saguner AM, Zbinden S, Khattab AA. LAD dissection following parachute belt trauma during BASE jumping. Int J Cardiol 2012; 159:e25-6. [PMID: 22204851 DOI: 10.1016/j.ijcard.2011.11.060] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2011] [Accepted: 11/26/2011] [Indexed: 10/14/2022]
|
45
|
Räber L, Kelbæk H, Ostojic M, Baumbach A, Heg D, Tüller D, von Birgelen C, Roffi M, Moschovitis A, Khattab AA, Wenaweser P, Bonvini R, Pedrazzini G, Kornowski R, Weber K, Trelle S, Lüscher TF, Taniwaki M, Matter CM, Meier B, Jüni P, Windecker S. Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial. JAMA 2012; 308:777-87. [PMID: 22910755 DOI: 10.1001/jama.2012.10065] [Citation(s) in RCA: 246] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
CONTEXT The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS A prospective, randomized, single-blinded, controlled trial of 1161 patients presenting with STEMI at 11 sites in Europe and Israel between September 19, 2009, and January 25, 2011. Clinical follow-up was performed at 1 and 12 months. INTERVENTION Patients were randomized 1:1 to receive the biolimus-eluting stent (n = 575) or the bare-metal stent (n = 582). MAIN OUTCOME MEASURES Primary end point was the rate of major adverse cardiac events, a composite of cardiac death, target vessel-related reinfarction, and ischemia-driven target-lesion revascularization at 1 year. RESULTS Major adverse cardiac events at 1 year occurred in 24 patients (4.3%) receiving biolimus-eluting stents with biodegradable polymer and 49 patients (8.7%) receiving bare-metal stents (hazard ratio [HR], 0.49; 95% CI, 0.30-0.80; P = .004). The difference was driven by a lower risk of target vessel-related reinfarction (3 [0.5%] vs 15 [2.7%]; HR, 0.20; 95% CI, 0.06-0.69; P = .01) and ischemia-driven target-lesion revascularization (9 [1.6%] vs 32 [5.7%]; HR, 0.28; 95% CI, 0.13-0.59; P < .001) in patients receiving biolimus-eluting stents compared with those receiving bare-metal stents. Rates of cardiac death were not significantly different (16 [2.9%] vs 20 [3.5%], P = .53). Definite stent thrombosis occurred in 5 patients (0.9%) treated with biolimus-eluting stents and 12 patients (2.1%; HR, 0.42; 95% CI, 0.15-1.19; P = .10) treated with bare-metal stents. CONCLUSION Compared with a bare-metal stent, the use of biolimus-eluting stents with a biodegradable polymer resulted in a lower rate of the composite of major adverse cardiac events at 1 year among patients with STEMI undergoing primary PCI. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00962416.
Collapse
|
46
|
Stortecky S, Schmid V, Windecker S, Kadner A, Pilgrim T, Buellesfeld L, Khattab AA, Wenaweser P. Improvement of physical and mental health after transfemoral transcatheter aortic valve implantation. EUROINTERVENTION 2012; 8:437-43. [DOI: 10.4244/eijv8i4a69] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
47
|
Kalesan B, Stefanini GG, Räber L, Schmutz M, Baumgartner S, Hitz S, Baldinger SH, Pilgrim T, Moschovitis A, Wenaweser P, Büllesfeld L, Khattab AA, Meier B, Jüni P, Windecker S. Long-term comparison of everolimus- and sirolimus-eluting stents in patients with acute coronary syndromes. JACC Cardiovasc Interv 2012; 5:145-54. [PMID: 22361598 DOI: 10.1016/j.jcin.2011.11.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 09/22/2011] [Accepted: 11/18/2011] [Indexed: 01/15/2023]
Abstract
OBJECTIVES The goal of this study was to compare the long-term clinical outcome between everolimus-eluting stent (EES) and sirolimus-eluting stent (SES) in patients with acute coronary syndromes (ACS). BACKGROUND EES have not been directly compared with SES in ACS patients to date. METHODS Between 2004 and 2009, 1,746 consecutive ACS patients (ST-segment elevation ACS [STE-ACS]: 33.5%; non-ST-segment elevation ACS [NSTE-ACS]: 66.5%) were treated with EES (n=903) or SES (n=843). Using propensity score matching, clinical outcome was compared among 705 matched pairs of ACS patients treated with EES and SES. RESULTS Through 3 years, the primary endpoint-the composite of death, myocardial infarction (MI), and target vessel revascularization (TVR)-occurred in 13.8% of EES- and 17.7% of SES-treated ACS patients (hazard ratio [HR]: 0.72, 95% confidence interval [CI]: 0.54 to 0.95, p=0.02). The difference in favor of EES was driven by a lower risk of TVR (5.7% vs. 8.8%, HR: 0.65, 95% CI: 0.43 to 0.98, p=0.04) and a trend toward a lower risk of MI (2.1% vs. 3.3%, HR: 0.56, 95% CI: 0.29 to 1.12, p=0.10). The risk of death (7.2% vs. 8.8%, HR: 0.75, 95% CI: 0.50 to 1.10, p=0.14) showed no difference between EES and SES. The treatment effect in favor of EES for the primary endpoint was similar for patients with STE-ACS (16.4% vs. 18.5%, HR: 0.80, 95% CI: 0.50 to 1.27) and NSTE-ACS (12.4% vs. 17.3%; HR: 0.67, 95% CI: 0.47 to 0.96; pfor interaction=0.56) and across major subgroups. Definite (0.4% vs. 1.8%, p=0.03), and definite or probable stent thrombosis (3.4% vs. 6.1%, p=0.02) were less frequent among EES- than SES-treated ACS patients. CONCLUSIONS Among patients with ACS, the unrestricted use of EES is associated with improved clinical outcome compared with SES during long-term follow-up to 3 years. Notably, the risk of stent thrombosis was lower among EES-treated ACS patients.
Collapse
|
48
|
Guérios EE, Schmid M, Gloekler S, Khattab AA, Wenaweser PM, Windecker S, Meier B. Left atrial appendage closure with the Amplatzer cardiac plug in patients with atrial fibrillation. Arq Bras Cardiol 2012; 98:528-36. [PMID: 22584492 DOI: 10.1590/s0066-782x2012005000044] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2011] [Accepted: 12/26/2011] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Percutaneous left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OA) for prevention of thromboembolic stroke in patients with non-valvular atrial fibrillation (NVAF). OBJECTIVE To describe the immediate results and short- to medium-term clinical follow-up (FU) of patients that underwent LAAC with Amplatzer Cardiac Plug (ACP) implantation in a single reference center. METHODS Eighty-six consecutive patients with NVAF, contraindication to OA, and CHADS2 score=2.6 ± 1.2 underwent LAAC with ACP implantation. Clinical and echocardiographic FU was performed at least four months after the procedure. RESULTS All implants were guided by angiography alone. Procedural success was 99% (one patient suffered a cardiac tamponade requiring pericardiocentesis, and the procedure was waived). There were four major complications (the already mentioned cardiac tamponade, two transient ischemic attacks and one device embolization with percutaneous retrieval) and two minor complications (one pericardial effusion without clinical significance and one non-significant ASD evidenced at FU). There was one in-hospital death after six days, unrelated to the procedure. All other patients were discharged without OA. After 25.9 patient-years of FU (69 patients), there were no strokes and no late device embolization. The LAA was completely closed in 97% of the cases. Six patients showed evidence of thrombus formation on the device, which resolved after three months of OA. CONCLUSION LAAC is associated with high success, acceptable complication rates, and promising FU results, and may be considered a valuable alternative or complement to OA for stroke prevention in patients with NVAF.
Collapse
|
49
|
Abdel-Wahab M, Baev R, Dieker P, Kassner G, Khattab AA, Toelg R, Sulimov D, Geist V, Richardt G. Long-term clinical outcome of rotational atherectomy followed by drug-eluting stent implantation in complex calcified coronary lesions. Catheter Cardiovasc Interv 2012; 81:285-91. [DOI: 10.1002/ccd.24367] [Citation(s) in RCA: 94] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 01/01/2012] [Accepted: 02/12/2012] [Indexed: 11/11/2022]
|
50
|
Stortecky S, Windecker S, Pilgrim T, Heg D, Buellesfeld L, Khattab AA, Huber C, Gloekler S, Nietlispach F, Mattle H, Jüni P, Wenaweser P. Cerebrovascular accidents complicating transcatheter aortic valve implantation: frequency, timing and impact on outcomes. EUROINTERVENTION 2012; 8:62-70. [DOI: 10.4244/eijv8i1a11] [Citation(s) in RCA: 89] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|