26
|
Hofer CK, Ganter MT, Matter-Ensner S, Furrer L, Klaghofer R, Genoni M, Zollinger A. Volumetric assessment of left heart preload by thermodilution: comparing the PiCCO-VoLEF system with transoesophageal echocardiography. Anaesthesia 2006; 61:316-21. [PMID: 16548948 DOI: 10.1111/j.1365-2044.2006.04537.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The new Volumetric Ejection Fraction monitoring system (VoLEF), when combined with the Pulse Contour Cardiac Output monitoring system (PiCCO) system, allows measurement of left and right heart end-diastolic volumes by thermodilution. The aim of this study was to evaluate whether the left heart end-diastolic volume index determined by the VoLEF system (LHEDI) better reflects left ventricular end-diastolic area index (LVEDAI) measured by transoesophageal echocardiography than does global end-diastolic volume index (GEDI) measured by the PiCCO system alone. Following induction of anaesthesia, PiCCO, VoLEF and transoesophageal echocardiography measurements were performed before and after a fluid challenge in 20 patients scheduled for elective cardiac surgery. Both left ventricular end-diastolic area index and global end-diastolic volume index, but not left heart end-diastolic volume index, significantly increased after fluid administration. Mean bias +/- 2 SD for DeltaLHEDI-DeltaLVEDAI was -2.2 +/- 32.0% and for DeltaGEDI-DeltaLVEDAI -0.6 +/- 16.8%. In contrast to global end-diastolic volume index, the use of left heart end-diastolic volume index determined by the VoLEF system cannot be recommended as an estimate of left ventricular preload.
Collapse
|
27
|
Dalbert S, Ganter MT, Furrer L, Klaghofer R, Zollinger A, Hofer CK. Effects of heparin, haemodilution and aprotinin on kaolin-based activated clotting time: in vitro comparison of two different point of care devices. Acta Anaesthesiol Scand 2006; 50:461-8. [PMID: 16548858 DOI: 10.1111/j.1399-6576.2006.00990.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND During cardiopulmonary bypass (CPB), measurement of kaolin-based activated clotting time (kACT) is a standard practice in monitoring heparin-induced anticoagulation. Despite the fact that the kACT test from the Sonoclot Analyzer (SkACT) has been commercially available for several years, no published data on the performance of SkACT are available. Thus, the aim of this in vitro study was to compare SkACT with an established kACT from Hemochron (HkACT). METHODS Blood was withdrawn from 25 patients before elective cardiac surgery. SkACT and HkACT were measured in duplicate after in vitro administration of heparin (0, 1, 2 and 3 U/ml), calcium-free lactated Ringer's solution (25% and 50% haemodilution) and aprotinin (200 kIU/ml). RESULTS A total of 600 duplicate kACT measurements were obtained from 25 cardiac surgery patients. Overall, mean bias +/- SD between SkACT and HkACT was 7 +/- 70 s (1.3% +/- 14.1%). Administration of heparin, haemodilution and aprotinin induced a comparable effect on both activated clotting time (ACT) tests. Mean bias ranged from -4 +/- 39 s (-1.7% +/- 12.9%) to 4 +/- 78 s (3.2% +/- 15.6%) for heparinzed blood samples after haemodilution or aprotinin application and increased after combined aprotinin administration and haemodilution. After haemodilution and administration of aprotinin, both ACT tests were less reliable for values >480 s in heparinized blood samples. CONCLUSION Accuracy and performance of SkACT and HkACT were comparable after in vitro administration of heparin, aprotinin and haemodilution. Both ACT tests were considerably affected by aprotinin and haemodilution.
Collapse
|
28
|
|
29
|
Hofer C, Ganter M, Fodor P, Tavakoli R, Genoni M, Zollinger A. Crit Care 2006; 10:P340. [DOI: 10.1186/cc4687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
30
|
Hofer CK, Worn M, Tavakoli R, Sander L, Maloigne M, Klaghofer R, Zollinger A. Influence of body core temperature on blood loss and transfusion requirements during off-pump coronary artery bypass grafting: a comparison of 3 warming systems. J Thorac Cardiovasc Surg 2005; 129:838-43. [PMID: 15821652 DOI: 10.1016/j.jtcvs.2004.07.002] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND The aim of this prospective randomized trial was to evaluate the efficacy of 3 intraoperative warming systems (Warm-Touch, Thermamed SmartCare OP system, and Allon 2001) on maintenance of normothermia and to investigate their effects on perioperative bleeding and transfusion requirements in patients undergoing off-pump coronary artery bypass grafting. METHODS With institutional approval/patient informed consent, 90 patients presenting for elective multiple off-pump coronary artery bypass grafting were randomly assigned to 1 of the 3 warming systems. Active warming was started after the induction of anesthesia. Perioperative transfusion was based on international guidelines. Body core temperature was recorded every 30 minutes during operation. Perioperative blood loss, autotransfusion, and allogenic transfusions were recorded. Analysis of variance was performed with post hoc Scheffé tests and chi 2 tests. RESULTS Normothermia could be sufficiently maintained during operation by the Allon 2001 only. Final body core temperature was 34.7 degrees C +/- 0.9 degrees C (Warm-Touch), 35.6 degrees C +/- 0.8 degrees C (Thermamed SmartCare OP), and 36.5 degrees C +/- 0.4 degrees C (Allon 2001; P < .001, Warm-Touch vs Thermamed SmartCare OP, Warm-Touch vs Allon 2001, and Thermamed SmartCare OP vs Allon 2001). Perioperative blood loss was 2683 +/- 1049 mL (Warm-Touch), 2300 +/- 788 mL (Thermamed SmartCare OP), and 1497 +/- 497 mL (Allon 2001; P = .195, Warm-Touch vs Thermamed SmartCare OP; P < .001, Warm-Touch vs Allon 2001; P = .001, Thermamed SmartCare OP vs Allon 2001). Transfusion requirements were 1097 +/- 874 mL (Warm-Touch), 986 +/- 744 mL (Thermamed SmartCare OP), and 431 +/- 387 mL (Allon 2001; P = .838, Warm-Touch vs Thermamed SmartCare OP; P = .003, Warm-Touch vs Allon 2001; P = .013, Thermamed SmartCare OP vs Allon 2001). Free of allogenic transfusion were 15 (51.7%; Warm-Touch), 18 (60%; Thermamed SmartCare OP), and 24 (82.8%; Allon 2001) patients ( P = .037). CONCLUSIONS The goal of normothermia during off-pump coronary artery bypass grafting was best achieved by the Allon system. With this concept, overall blood loss and transfusion requirements were reduced, hence indicating improved quality of perioperative care.
Collapse
|
31
|
Hofer CK, Furrer L, Matter-Ensner S, Maloigne M, Klaghofer R, Genoni M, Zollinger A. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth 2005; 94:748-55. [PMID: 15790674 DOI: 10.1093/bja/aei123] [Citation(s) in RCA: 126] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND End-diastolic volume indices determined by transpulmonary thermodilution and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring. The aim of this study was to compare volume preload monitoring using the two different thermodilution techniques with left ventricular preload assessment by transoesophageal echocardiography (TOE). METHODS Twenty patients undergoing elective cardiac surgery with preserved left-right ventricular function were studied after induction of anaesthesia. Conventional haemodynamic variables, global end-diastolic volume index using the pulse contour cardiac output (PiCCO) system (GEDVI(PiCCO)), continuous end-diastolic volume index (CEDVI(PAC)) measured by a modified pulmonary artery catheter (PAC), left ventricular end-diastolic area index (LVEDAI) using TOE and stroke volume indices (SVI) were recorded before and 20 and 40 min after fluid replacement therapy. Analysis of variance (Bonferroni-Dunn), Bland-Altman analysis and linear regression were performed. RESULTS GEDVI(PiCCO), CEDVI(PAC), LVEDAI and SVI(PiCCO/PAC) increased significantly after fluid load (P<0.05). An increase >10% for GEDVI(PiCCO) and LVEDAI was observed in 85% and 90% of the patients compared with 45% for CEDVI(PAC). Mean bias (2 SD) between percentage changes (delta) in GEDVI(PiCCO) and deltaLVEDAI was -3.2 (17.6)% and between deltaCEDVI(PAC) and deltaLVEDAI -8.7 (30.0)%. The correlation coefficient (r2) for deltaGEDVI(PiCCO) vs deltaLVEDAI was 0.658 and for deltaCEDVI(PAC) vs deltaLVEDAI 0.161. The relationship between deltaGEDVI(PiCCO) and deltaSVI(PiCCO) was stronger (r2=0.576) than that between deltaCEDVI(PAC) and deltaSVI(PAC) (r2=0.267). CONCLUSION GEDVI assessed by the PiCCO system gives a better reflection of echocardiographic changes in left ventricular preload, in response to fluid replacement therapy, than CEDVI measured by a modified PAC.
Collapse
|
32
|
Garcia C, Julier K, Bestmann L, Zollinger A, von Segesser LK, Pasch T, Spahn DR, Zaugg M. Preconditioning with sevoflurane decreases PECAM-1 expression and improves one-year cardiovascular outcome in coronary artery bypass graft surgery. Br J Anaesth 2005; 94:159-65. [PMID: 15556966 DOI: 10.1093/bja/aei026] [Citation(s) in RCA: 134] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Cardiac preconditioning is thought to be involved in the observed decreased coronary artery reocclusion rate in patients with angina preceding myocardial infarction. We prospectively examined whether preconditioning by sevoflurane would decrease late cardiac events in patients undergoing coronary artery bypass graft (CABG) surgery. METHODS Seventy-two patients scheduled for elective CABG surgery were randomized to preconditioning by sevoflurane (10 min at 4 vol%) or placebo. For all patients, follow-up of adverse cardiac events was obtained 6 and 12 months after surgery. Transcript levels for platelet-endothelial cell adhesion molecule-1 (PECAM-1/CD31), catalase and heat shock protein 70 (Hsp70) were determined in atrial biopsies after sevoflurane preconditioning. RESULTS Pharmacological preconditioning by sevoflurane reduced the incidence of late cardiac events during the first year after CABG surgery (sevoflurane 3% vs 17% in the placebo group, log-rank test, P=0.038). One patient in the sevoflurane group and three patients in the placebo group experienced new episodes of congestive heart failure and three additional patients had coronary artery reocclusion. Perioperative peak concentrations for myocardial injury markers were higher in patients with subsequent late cardiac events [NTproBNP, 9031 (4125) vs 3049 (1906) ng litre(-1), P<0.001; cTnT, 1.31 (0.88) vs 0.46 (0.29) microg litre(-1), P<0.001]. Transcript levels were reduced for PECAM-1 and increased for catalase but unchanged for Hsp70 in atrial biopsies after sevoflurane preconditioning. CONCLUSIONS This prospective randomized clinical study provides evidence of a protective role for pharmacological preconditioning by sevoflurane in late cardiac events in CABG patients, which may be related to favourable transcriptional changes in pro- and antiprotective proteins.
Collapse
|
33
|
Hofer CK, Ganter MT, Furrer L, Guthauser G, Klaghofer R, Zollinger A. Welche Bed�rfnisse und Erwartungen haben Patienten an die An�sthesie? Anaesthesist 2004; 53:1061-8. [PMID: 15517113 DOI: 10.1007/s00101-004-0763-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND This prospective survey aimed at elucidating the patients' expectations and needs regarding the pre-anaesthetic visit and the forthcoming anaesthesia. The same questionnaire was answered by both patients and anaesthesiologists. METHODS A total of 200 ASA I-III patients were interviewed prior to the preoperative anaesthetic visit. The questionnaire consisted of the topics preoperative affective situation, information and self-estimation of anaesthesia knowledge, expectations regarding the pre-anaesthetic visit/anaesthesia and extent of information concerning the perioperative course including risk and possible complications. The same questionnaire was presented to 35 certified anaesthesiologists with the request to estimate the patients' answers. Answers were rated using a Likert-scale, a comparison of patients' and anaesthesiologists' replies was performed. RESULTS For all 5 topics considerable differences between patients' answers and anaesthesiologists' rating were found (e.g. for the assessment of the affective situation, the relevance of family physicians as information source, the desired anaesthetic technique or the extent of anaesthesia-related risk information). No differences were observed for the importance of an anaesthesiologist as information source and fear reduction by the pre-anaesthetic visit. CONCLUSIONS Anaesthesiologists tend to misinterpret many patients' expectations and attitudes. The results demonstrate the potential for quality improvement of the pre-anaesthetic visit.
Collapse
|
34
|
Hofer CK, Bühlmann S, Klaghofer R, Genoni M, Zollinger A. Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique. Acta Anaesthesiol Scand 2004; 48:653-7. [PMID: 15101865 DOI: 10.1111/j.1399-6576.2004.00371.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Assessment of cardiac output (CO) by the indocyanine green (ICG) dye dilution technique (IDD) with transcutaneous signal detection may be a less invasive alternative to the pulmonary artery catheter (PAC). The aim of this study was to determine the accuracy and reliability of the DDG2001 analyzer (Nihon Kohden Corp, Tokyo, Japan) using a finger (IDDf) and a nose (IDDn) sensor as compared with the thermodilution technique by PAC. METHODS In 31 consecutive patients after routine cardiac surgery, CO measurements were performed by IDD compared with the thermodilution technique following postoperative haemodynamic stabilization in the intensive care unit. Repeated measurements were made at 30-min intervals. CO was determined by iced water bolus (IWB: mean of three repeated injections) and IDDf or IDDn, respectively (mean of three repeated ICG injections). RESULTS Thirty-three per cent of all measurements for IDDf and 9% for IDDn failed due to a missing signal detection. Mean bias for IDDf to IWB was -0.5 l min(-1).m(-2) (limits of agreement: -1.8/0.8 l min(-1).m(-2)) and for IDDn to IWB was -0.1 l min(-1).m(-2) (limits of agreement: -1.6/1.5 l min(-1).m(-2)). Correlation between IDDf and IWB (r = 0.2) was found to be inferior to the correlation between IDDn and IWB (r = 0.5). CONCLUSION The IDD showed a systematic bias compared with the IWB and its performance was limited due to signal detection failure. Therefore, the DDG2001 analyzer cannot be recommended as a substitute for the PAC in routine monitoring of cardiac output after cardiac surgery.
Collapse
|
35
|
Hofer CK, Zollinger A, Rak M, Matter-Ensner S, Klaghofer R, Pasch T, Zalunardo MP. Therapeutic impact of intra-operative transoesophageal echocardiography during noncardiac surgery. Anaesthesia 2004; 59:3-9. [PMID: 14687091 DOI: 10.1111/j.1365-2044.2004.03459.x] [Citation(s) in RCA: 85] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The impact of transoesophageal echocardiography on haemodynamic management during elective noncardiac surgery was assessed during this observational prospective database analysis. Ninety-nine consecutive patients were studied, who were at risk of intra-operative myocardial ischaemia or haemodynamic instability (Class II indications) and were undergoing vascular, visceral or chest surgery. A total of 165 new echocardiographic findings were recorded. Based on these findings changes in drug therapy were made in 47% and changes in fluid therapy in 24% of patients. Left ventricular wall motion abnormalities were seen in 32% and other relevant diagnoses made in 10%. Echocardiography showed a significant impact on drug therapy in patients with pre-operative systolic wall motion abnormalities (vasodilators: OR = 7.1, CI 95% = 2.1/24.0; vasopressors: OR = 3.3, CI 95% = 1.2/9.1) and patients with a history of left heart failure (vasodilators: OR = 5.2, CI 95% = 1.0/31.4). Fluid therapy was significantly influenced by echocardiographic findings during liver and lung transplantation (50% compared with 24% during other surgical interventions, p < 0.05).
Collapse
|
36
|
Hofer CK, Zollinger A, Büchi S, Klaghofer R, Serafino D, Bühlmann S, Buddeberg C, Pasch T, Spahn DR. Patient well-being after general anaesthesia: a prospective, randomized, controlled multi-centre trial comparing intravenous and inhalation anaesthesia. Br J Anaesth 2003; 91:631-7. [PMID: 14570783 DOI: 10.1093/bja/aeg243] [Citation(s) in RCA: 80] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The aim of this study was to assess postoperative patient well-being after total i.v. anaesthesia compared with inhalation anaesthesia by means of validated psychometric tests. METHODS With ethics committee approval, 305 patients undergoing minor elective gynaecologic or orthopaedic interventions were assigned randomly to total i.v. anaesthesia using propofol or inhalation anaesthesia using sevoflurane. The primary outcome measurement was the actual mental state 90 min and 24 h after anaesthesia assessed by a blinded observer using the Adjective Mood Scale (AMS) and the State-Trait-Anxiety Inventory (STAI). Incidence of postoperative nausea and vomiting (PONV) and postoperative pain level were determined by Visual Analogue Scale (VAS) 90 min and 24 h after anaesthesia (secondary outcome measurements). Patient satisfaction was evaluated using a VAS 24 h after anaesthesia. RESULTS The AMS and STAI scores were significantly better 90 min after total i.v. anaesthesia compared with inhalation anaesthesia (P=0.02, P=0.05, respectively), but equal 24 h after both anaesthetic techniques (P=0.90, P=0.78, respectively); patient satisfaction was comparable (P=0.26). Postoperative pain was comparable in both groups 90 min and 24 h after anaesthesia (P=0.11, P=0.12, respectively). The incidence of postoperative nausea was reduced after total i.v. compared with inhalation anaesthesia at 90 min (7 vs 35%, P<0.001), and 24 h (33 vs 52%, P=0.001). CONCLUSION Total i.v. anaesthesia improves early postoperative patient well-being and reduces the incidence of PONV.
Collapse
|
37
|
Ganter M, Zollinger A. Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device. Br J Anaesth 2003; 91:397-407. [PMID: 12925481 DOI: 10.1093/bja/aeg176] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
This review focuses on the development, current techniques, and clinical use of continuous intravascular blood gas monitoring (CIBM) devices in anaesthesia and intensive care. The operating principles, range of application, performance, limitations, costs, and impact on patient treatment and outcome, are discussed. Studies of early and currently available CIBM devices were analysed. At present, the Paratrend 7+ (PT7+) for adults and Neotrend (NT) for newborns are the only commercially available CIBM systems. The PT7+ contains three optical sensors to measure PO(2), PCO(2) and pH, as well as a thermocouple to measure temperature. The NT is a modification of the PT7+ to continuously monitor PO(2), PCO(2), pH and temperature in newborns. Under laboratory conditions, good performance over a wide range of blood gas values was observed with the Paratrend 7 (PT7. Performance in the clinical setting was not as satisfactory, especially for PO(2) values. However, the performance and accuracy of CIBM devices appear to be sufficient for clinical use and they are being used clinically in selected patient groups. Several factors affecting the performance of CIBM are considered.
Collapse
|
38
|
Hofer CK, Lang D, Suhner M, Straumann E, Zollinger A. [Complete heart block after spinal and general anaesthesia]. Anaesthesist 2003; 52:326-8. [PMID: 12715135 DOI: 10.1007/s00101-003-0457-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Complete atrioventricular block occurred during spinal and subsequent general anaesthesia in a 74-year-old patient with known arterial hypertension but without heart conduction abnormality. Drug therapy and intermittent transcutaneous pacing was successful. A decrease of arterial pressure by more than 40% preceded the heart blockade in the course of both events. Subsequent cardiologic examination revealed evidence of a discrete hypertensive heart disease. Relative ischemia of the atrioventricular region during anaesthesia was suggested as an aetiology. When the patient presented for the next operation, again general anaesthesia was applied, and invasive arterial blood pressure monitoring as well as catecholamine support were used and no further atrioventricular blockade occurred. The case demonstrates the possible recurrence of an intraoperative complete atrioventricular blockade in an older patient without pre-existing conduction abnormalities and only minor signs of heart disease, irrespective of the anaesthesia technique. Under these circumstances transcutaneous pacing should always be in place. Maintenance of coronary perfusion pressure is essential and invasive blood pressure monitoring is recommended.
Collapse
|
39
|
Hofer CK, Straumann E, Genoni M, Zollinger A. Profound drug-induced thrombocytopenia before urgent cardiopulmonary bypass. Interact Cardiovasc Thorac Surg 2002; 1:63-5. [PMID: 17669961 DOI: 10.1016/s1569-9293(02)00016-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
A patient with acute coronary syndrome scheduled for urgent coronary artery bypass grafting developed a profound thrombocytopenia during therapy with intravenous heparin and the glycoprotein IIb/IIIa inhibitor tirofiban. Heparin-induced thrombocytopenia and all other possible aetiologies were unlikely and the low platelet count had to be attributed to tirofiban. Anticoagulation during cardiopulmonary bypass was successfully managed with standard heparin. Implications for the diagnosis of coagulation disorders and the management of perioperative anticoagulation are discussed.
Collapse
|
40
|
Hofer CK, Zollinger A, Tucci M, van Gessel E, Alon E, Klaghofer R. Is traditional fasting policy changing? Results of a Swiss survey on current practice. Eur J Anaesthesiol 2002; 19:894-6. [PMID: 12510909 DOI: 10.1017/s0265021502211436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
41
|
Hofer CK, Zalunardo MP, Klaghofer R, Spahr T, Pasch T, Zollinger A. Changes in intrathoracic blood volume associated with pneumoperitoneum and positioning. Acta Anaesthesiol Scand 2002; 46:303-8. [PMID: 11939922 DOI: 10.1034/j.1399-6576.2002.t01-1-460313.x] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND It is still controversial whether elevated cardiac filling pressures after the onset of pneumoperitoneum are the consequence of increased intrathoracic pressure or of increased venous return. The aim of this study was to assess the effects of pneumoperitoneum and body positioning on intrathoracic blood volume (ITBV). METHODS Thirty anesthetized patients were randomly assigned to have CO2-pneumoperitoneum (13 mmHg) either in a supine, in a 15 degrees head-up tilt or in a 15 degrees head-down tilt position. Measurements of ITBV and hemodynamics by the double indicator method were recorded after induction of anesthesia and application of a fluid bolus (Lactated Ringer's solution 10 ml/kg), after positioning and after induction of pneumoperitoneum. RESULTS Intrathoracic blood volume index (ITBVI) increased significantly after induction of pneumoperitoneum in all body positions (supine: from 18.5 +/- 3.3 -20.2 +/- 5.2 ml/kg (+6%) head-up from 16.7 +/- 3.8 - 17.4 +/- 3.7 ml/kg (+16%) and head-down: from 19.8 +/- 5.6 - 20.5 +/- 5.9 ml/kg (+14%)). Heart rate did not change significantly in any of the groups. Cardiac index showed a statistically significant change in the head-down position with pneumoperitoneum (-11%). A good correlation was found for stroke volume (SV) with ITBV (r = 0.79), but not with central venous pressure (r = 0.26). Systemic vascular resistance index increased significantly in all three groups (supine +6%, head-up +16%, head-down position +14%). CONCLUSION The present study indicates that the onset of pneumoperitoneum, even with moderate intra-abdominal pressures, is associated with an increased intrathoracic blood volume in ASA I/II patients.
Collapse
|
42
|
Held J, Brüesch M, Zollinger A, Pasch T, Krueger H. [Participation--oriented analysis of the anesthesia workplace. A work system for anesthesia in a multidisciplinary operating room]. Anaesthesist 2002; 51:110-5. [PMID: 11963302 DOI: 10.1007/s00101-001-0265-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
INTRODUCTION The aim of this study was the detection and understanding of weak points in the ergonomic design of anaesthesia workplaces in a multidisciplinary operating room facility. METHODS Analysis of workplaces and of working processes by means of observations, computer-supported task recording and video-photo documentation. During guided interviews the participants were provided with material for naming-by-pointing and drawing. Subsequently, the background of the problems encountered and possible improvements were visualised. RESULTS Important deficits were devices not positioned within reach and view, difficulties in operating the lines connecting the patient and the devices, and inconsistent workplace layouts. These were caused by erroneous planning of the facility and disregarding ergonomic principles in equipment design. The initial improvements implemented were the development of a new concept for a flexible equipment positioning and the design of a tool for cable handling. DISCUSSION AND CONCLUSION Although from the very beginning of the study the anaesthesia personnel quoted the handling of the lines connecting patients and devices as the main cause for working difficulties, the external ergonomist could contribute to a broader view of the problems. The method presented here initiated a mutual learning process between ergonomist and users and resulted in a common understanding of the problems and their causes. Compared to the traditional consulting process, more time and efforts were necessary but were offset by the users' acceptance of the improvements and the prevention of design errors.
Collapse
|
43
|
Hofer CK, Ganter M, Tucci M, Klaghofer R, Zollinger A. How reliable is length-based determination of body weight and tracheal tube size in the paediatric age group? The Broselow tape reconsidered. Br J Anaesth 2002; 88:283-5. [PMID: 11878662 DOI: 10.1093/bja/88.2.283] [Citation(s) in RCA: 112] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The Broselow tape was designed to estimate body weight and tracheal tube size on the basis of the body length of emergency paediatric patients. The tape was validated previously in US populations. We assessed its accuracy in a sample of European children by reviewing paediatric anaesthetic charts at the Triemli City Hospital for 1999. METHODS Age, body length and body weight measured before surgery as well as the size of the tracheal tube used were recorded. The body weight was estimated on the basis of body length using the Broselow tape and was compared with the measured weight. Tracheal tube size selections using the Broselow tape and an age-based formula were compared with the size of the tube used. RESULTS A good correlation was found between the Broselow weight and the measured weight (r2=0.88). Bland-Altman analysis revealed a mean bias of -0.52 kg for the entire study population. For children < or = 20 kg the mean bias was -0.05 kg, and for children > 20 kg was -1.05 kg. The Broselow weight was found to be within a 10% error of the measured weight in 65% of children. Tracheal tube selection by the Broselow tape method was adequate in 55% but underestimated the actual tube size in 39%. The age-based formula matched the actual tracheal tube size in 41% of children but overestimated it in 57%. CONCLUSIONS The Broselow tape is an accurate means to assess body weight from length in smaller children; in older children it underestimated body weight. Endotracheal tube size selection by the Broselow tape appears to match the size of the tube used better than the age-based formula. The results in a European sample of children are comparable to the US data.
Collapse
|
44
|
Hofer C, Zalunardo MP, Zollinger A. Total intravenous anaesthesia in a patient with familial hypokalaemic periodic paralysis*. Anaesthesia 2001. [DOI: 10.1111/j.1365-2044.2001.02268.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
45
|
Hofer C, Zalunardo MP, Zollinger A. Total intravenous anaesthesia in a patient with familial hypokalaemic periodic paralysis. Anaesthesia 2001; 56:1082-5. [PMID: 11703241 DOI: 10.1046/j.1365-2044.2001.02268.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A 35-year-old woman with known familial hypokalaemic periodic paralysis received general anaesthesia for reduction of bilateral breast hyperplasia. Uncomplicated general anaesthesia was performed using a propofol target-controlled infusion, remifentanil infusion and bolus doses of mivacurium with neuromuscular function monitoring. Plasma potassium concentrations were controlled intermittently in the peri-operative period and supplemented to achieve normokalaemia. Despite continuous substitution, an episode of low plasma potassium concentration occurred during the recovery period; this was without any clinical signs of muscle paralysis or respiratory distress.
Collapse
|
46
|
Weiss M, Bernoulli L, Zollinger A. [The NACA scale. Construct and predictive validity of the NACA scale for prehospital severity rating in trauma patients]. Anaesthesist 2001; 50:150-4. [PMID: 11315486 DOI: 10.1007/s001010170030] [Citation(s) in RCA: 97] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The NACA-scale is used in many Austrian, German and Swiss emergency medical systems for demographic description of emergency patients. Little attention has been payed to the evaluation of its construct and predictive validity. In 427 consecutive trauma patients rescued in primary mission the NACA-Scale and the Injury Severity Score (ISS) were determined. Outcome data were obtained from medical charts and by written or telephone requests. Data were analysed with Spearman-Rank-Correlation. NACA-Grade and ISS-values showed only a moderate correlation with a considerably large spread (Rho = 0.721). Both severity scores demonstrated a good correlation to mortality (Rho = 0.976/0.994) and to transfer to an ICU (Rho = 0.964/0.943), as well a moderate correlation to the duration of ICU-stay (Rho = 0.722/0.756) and of hospital stay (Rho = 0.558/0.694). The NACA-scale adequately describes life threat in trauma victims and correlates well with morbidity and mortality. Thus, it is a valuable tool for demographic purposes in emergency medical systems. For more precise prehospital severity rating in trauma patients, the NACA-scale should be supplemented or replaced by a physiologically based prehospital severity score.
Collapse
|
47
|
Abstract
This review summarizes recent reports on preoperative pulmonary evaluation focusing on the impact on outcome in thoracic and non-thoracic surgery. Data suggest that hitherto widely accepted pulmonary function tests do not predict perioperative complications. Therefore, they may not be considered alone to decide on the patient's operability. So-called prohibitive lung function parameters should no longer be used to deny a potentially curative lung resection. A more clinically oriented, interdisciplinary approach to severely compromised patients may be best suited to discuss and solve their problems.
Collapse
|
48
|
Hofer C, Tucci M, van Gessel E, Alon E, Zollinger A. Is traditional preoperative fasting policy changing? Results of a Swiss survey on current practice. Eur J Anaesthesiol 2001. [DOI: 10.1097/00003643-200100001-00031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
49
|
Zalunardo MP, Zollinger A, Szelloe P, Spahn DR, Seifert B, Pasch T. [Cardiovascular stress protection following anesthesia induction. Comparison of clonidine and esmolol]. Anaesthesist 2001; 50:21-5. [PMID: 11220254 DOI: 10.1007/s001010050958] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Alpha-2-adrenoceptor-agonists as well as cardioselective betareceptor-antagonists have been shown to blunt stress response due to tracheal intubation. The purpose of our study was to investigate,whether clonidine or esmolol is more efficient to attenuate stress response due to intubation.44 patients were randomly assigned to receive either clonidine (n=22; 3 microg/kg) or esmolol (n=22; 2 mg/kg) immediately prior to a standardized induction of anaesthesia. Heart rate, arterial blood pressure, cardiac output, epinephrine and norepinephrine plasma concentrations were measured before,during and 10 min after intubation. Blood pressure was measured invasively and cardiac output was determined by transthoracic echocardiography. Absolute values and increase of mean arterial pressure and norepinephrine plasma concentrations were significantly less in the clonidine group (p<0,05). Clonidine (3 microg/kg) is more efficient than esmolol (2 mg/kg) in blunting stress response due to endotracheal intubation.
Collapse
|
50
|
Jamnicki M, Bombeli T, Seifert B, Zollinger A, Camenzind V, Pasch T, Spahn DR. Low- and medium-molecular-weight hydroxyethyl starches: comparison of their effect on blood coagulation. Anesthesiology 2000; 93:1231-7. [PMID: 11046211 DOI: 10.1097/00000542-200011000-00016] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND High-molecular-weight hydroxyethyl starch (HES) compromises blood coagulation more than medium-molecular-weight HES. The authors compared medium molecular weight HES (200 kd [HES200]) and low-molecular-weight HES (70 kd [HES70]). METHODS In a prospective, double-blind, randomized-sequence crossover study, 22 male volunteers received 15 ml/kg HES200 and HES70. Blood samples were taken before and 5 min, 30 min, 1 h, 2 h, 4 h, 8 h, and 24 h after infusion. The following parameters were analyzed at all time points: prothrombin time, activated partial thromboplastin time, fibrinogen, factor VIII, antigenetic and functional von Willebrand factor, platelets, Thrombelastograph analysis parameters (reaction time, coagulation time, maximum amplitude, angle alpha, and clot lysis 30 and 60 min after maximum amplitude), ionized calcium, hematocrit, HES plasma concentration, molecular weight (weight average and number average), molar substitution, and polydispersity (weight average/number average). Repeated-measures analysis of variance (P < 0.05) was used to compare the response of the aforementioned parameters to the infusion of HES70 and HES200. RESULTS Both HES solutions had a significant impact on all parameters. A slightly greater compromise with HES200 was found in activated partial thromboplastin time (P = 0.010), factor VIII (P = 0.009), antigenetic von Willebrand factor (P = 0.041), functional von Willebrand factor (P = 0.026), maximum amplitude (P = 0.008), and angle alpha (P = 0.003). No difference was established with the other parameters. HES concentration (P < 0.001), weight average (P < 0.001), number average (P < 0.001), and polydispersity (P < 0.001) were higher with HES200. There was no difference with molar substitution (P = 0.091). CONCLUSIONS Low-molecular-weight hydroxyethyl starch (70 kd) compromises blood coagulation slightly less than HES200, but it is unclear whether this is clinically relevant.
Collapse
|