26
|
Pereda N, Arch M, Pérez-González A. A case study perspective on psychological outcomes after female genital mutilation. J OBSTET GYNAECOL 2012; 32:560-5. [DOI: 10.3109/01443615.2012.689893] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
27
|
González-Lluch C, Rodríguez-Cervantes PJ, Pérez-González A, Sancho-Bru JL. INFLUENCE OF INCLUDING PERIODONTAL LIGAMENT WHEN MODELING TEETH RESTORED WITH POST. J Biomech 2012. [DOI: 10.1016/s0021-9290(12)70173-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
28
|
Sancho-Bru JL, Mora MC, León BE, Pérez-González A, Iserte JL, Morales A. Grasp modelling with a biomechanical model of the hand. Comput Methods Biomech Biomed Engin 2012; 17:297-310. [DOI: 10.1080/10255842.2012.682156] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
29
|
Pérez-González A, Urtiaga AM, Ibáñez R, Ortiz I. State of the art and review on the treatment technologies of water reverse osmosis concentrates. WATER RESEARCH 2012; 46:267-283. [PMID: 22119366 DOI: 10.1016/j.watres.2011.10.046] [Citation(s) in RCA: 248] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2011] [Revised: 10/19/2011] [Accepted: 10/20/2011] [Indexed: 05/31/2023]
Abstract
The growing demand for fresh water is partially satisfied by desalination plants that increasingly use membrane technologies and among them reverse osmosis to produce purified water. Operating with water recoveries from 35% to 85% RO plants generate huge volumes of concentrates containing all the retained compounds that are commonly discharged to water bodies and constitute a potentially serious threat to marine ecosystems; therefore there is an urgent need for environmentally friendly management options of RO brines. This paper gives an overview on the potential treatments to overcome the environmental problems associated to the direct discharge of RO concentrates. The treatment options have been classified according to the source of RO concentrates and the maturity of the technologies. For the sake of clarity three different sources of RO concentrates are differentiated i) desalination plants, ii) tertiary processes in WWTP, and iii) mining industries. Starting with traditional treatments such as evaporation and crystallization other technologies that have emerged in last years to reduce the volume of the concentrate before disposal and with the objective of achieving zero liquid discharge and recovery of valuable compounds from these effluents are also reviewed. Most of these emerging technologies have been developed at laboratory or pilot plant scale (see Table 1). With regard to RO concentrates from WWTP, the manuscript addresses recent studies that are mainly focused on reducing the organic pollutant load through the application of innovative advanced oxidation technologies. Finally, works that report the treatment of RO concentrates from industrial sources are analyzed as well.
Collapse
|
30
|
Rodríguez-Cervantes PJ, Sancho-Bru JL, González-Lluch C, Pérez-González A, Barjau-Escribano A, Forner-Navarro L. Premolars restored with posts of different materials: fatigue analysis. Dent Mater J 2011; 30:881-6. [PMID: 22123012 DOI: 10.4012/dmj.2011-098] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, the results obtained are easier to interpret by both dentists and mechanical engineers. No differences were found, with the load and number of cycles considered, between glass fibre and stainless steel as material for the intraradicular post used in premolars restorations.
Collapse
|
31
|
Pérez-González A, González-Lluch C, Sancho-Bru JL, Rodríguez-Cervantes PJ, Barjau-Escribano A, Forner-Navarro L. Experimental strength of restorations with fibre posts at different stages, with and without using a simulated ligament. J Oral Rehabil 2011; 39:188-97. [PMID: 21913956 DOI: 10.1111/j.1365-2842.2011.02249.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The aim of this study was to analyse the strength and failure mode of teeth restored with fibre posts under retention and flexural-compressive loads at different stages of the restoration and to analyse whether including a simulated ligament in the experimental setup has any effect on the strength or the failure mode. Thirty human maxillary central incisors were distributed in three different groups to be restored with simulation of different restoration stages (1: only post, 2: post and core, 3: post-core and crown), using Rebilda fibre posts. The specimens were inserted in resin blocks and loaded by means of a universal testing machine until failure under tension (stage 1) and 50º flexion (stages 2-3). Half the specimens in each group were restored using a simulated ligament between root dentine and resin block and the other half did not use this element. Failure in stage 1 always occurred at the post-dentine interface, with a mean failure load of 191·2 N. Failure in stage 2 was located mainly in the core or coronal dentine (mean failure load of 505·9 N). Failure in stage 3 was observed in the coronal dentine (mean failure load 397·4 N). Failure loads registered were greater than expected masticatory loads. Fracture modes were mostly reparable, thus indicating that this post is clinically valid at the different stages of restoration studied. The inclusion of the simulated ligament in the experimental system did not show a statistically significant effect on the failure load or the failure mode.
Collapse
|
32
|
Pérez-González A, Iserte-Vilar JL, González-Lluch C. Interpreting finite element results for brittle materials in endodontic restorations. Biomed Eng Online 2011; 10:44. [PMID: 21635759 PMCID: PMC3123583 DOI: 10.1186/1475-925x-10-44] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2010] [Accepted: 06/02/2011] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Finite element simulation has been used in last years for analysing the biomechanical performance of post-core restorations in endodontics, but results of these simulations have been interpreted in most of the works using von Mises stress criterion. However, the validity of this failure criterion for brittle materials, which are present in these restorations, is questionable. The objective of the paper is to analyse how finite element results for brittle materials of endodontic restorations should be interpreted to obtain correct conclusions about the possible failure in the restoration. METHODS Different failure criteria (Von Mises, Rankine, Coulomb-Mohr, Modified Mohr and Christensen) and material strength data (diametral tensile strength and flexural strength) were considered in the study. Three finite element models (FEM) were developed to simulate an endodontic restoration and two typical material tests: diametral tensile test and flexural test. RESULTS Results showed that the Christensen criterion predicts similar results as the Von Mises criterion for ductile components, while it predicts similar results to all other criteria for brittle components. The different criteria predict different failure points for the diametral tensile test, all of them under multi-axial stress states. All criteria except Von Mises predict failure for flexural test at the same point of the specimen, with this point under uniaxial tensile stress. CONCLUSIONS From the results it is concluded that the Christensen criterion is recommended for FEM result interpretation in endodontic restorations and that the flexural test is recommended to estimate tensile strength instead of the diametral tensile test.
Collapse
|
33
|
González-Lluch C, Rodríguez-Cervantes PJ, Sancho-Bru JL, Pérez-González A, Barjau-Escribano A, Vergara-Monedero M, Forner-Navarro L. Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown. J Oral Rehabil 2009; 36:737-47. [PMID: 19702682 DOI: 10.1111/j.1365-2842.2009.01989.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried out using a reinforced glass-ceramic material. Failure loads were recorded and results were compared using the one-way anova. Secondly, the finite element technique was used to model the restored teeth and to compare the estimated stress distributions. The addition of the crown did not affect the strength of the restoration to any significant extent and post-diameter did not influence the biomechanical performance of either of the post-systems. The crown acts as a protector, thus eliminating the influence of the post-diameter that was found previously when using stainless steel posts, but it does not completely rule out the possibility of a root fracture. Significantly, lower failure loads were found experimentally for teeth restored with stainless steel posts. The stress distributions predicted by the model corroborated these findings and allowed the authors to propose the use of glass fibre posts as a more robust restorative technique.
Collapse
|
34
|
Berger G, Pérez-González A, Carbonell E, Arsuaga J, Bermúdez de Castro JM, Ku TL. Luminescence chronology of cave sediments at the Atapuerca paleoanthropological site, Spain. J Hum Evol 2008; 55:300-11. [DOI: 10.1016/j.jhevol.2008.02.012] [Citation(s) in RCA: 243] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2007] [Revised: 01/01/2008] [Accepted: 02/18/2008] [Indexed: 11/28/2022]
|
35
|
Pérez-González A, Vilar-Fernández JM, González-Manteiga W. Asymptotic properties of local polynomial regression with missing data and correlated errors. ANN I STAT MATH 2007. [DOI: 10.1007/s10463-007-0136-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
36
|
Pérez-González A, Fenollosa-Esteve C, Sancho-Bru JL, Sánchez-Marín FT, Vergara M, Rodríguez-Cervantes PJ. A modified elastic foundation contact model for application in 3D models of the prosthetic knee. Med Eng Phys 2007; 30:387-98. [PMID: 17513163 DOI: 10.1016/j.medengphy.2007.04.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2006] [Revised: 02/26/2007] [Accepted: 04/04/2007] [Indexed: 10/23/2022]
Abstract
Different models have been used in the literature for the simulation of surface contact in biomechanical knee models. However, there is a lack of systematic comparisons of these models applied to the simulation of a common case, which will provide relevant information about their accuracy and suitability for application in models of the implanted knee. In this work a comparison of the Hertz model (HM), the elastic foundation model (EFM) and the finite element model (FEM) for the simulation of the elastic contact in a 3D model of the prosthetic knee is presented. From the results of this comparison it is found that although the nature of the EFM offers advantages when compared with that of the HM for its application to realistic prosthetic surfaces, and when compared with the FEM in CPU time, its predictions can differ from FEM in some circumstances. These differences are considerable if the comparison is performed for prescribed displacements, although they are less important for prescribed loads. To solve these problems a new modified elastic foundation model (mEFM) is proposed that maintains basically the simplicity of the original model while producing much more accurate results. In this paper it is shown that this new mEFM calculates pressure distribution and contact area with accuracy and short computation times for toroidal contacting surfaces. Although further work is needed to confirm its validity for more complex geometries the mEFM is envisaged as a good option for application in 3D knee models to predict prosthetic knee performance.
Collapse
|
37
|
Rodriguez A, Pérez-González A, Nieto A. Influenza virus infection causes specific degradation of the largest subunit of cellular RNA polymerase II. J Virol 2007; 81:5315-24. [PMID: 17344288 PMCID: PMC1900203 DOI: 10.1128/jvi.02129-06] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
It has been described that influenza virus polymerase associates with RNA polymerase II (RNAP II). To gain information about the role of this interaction, we explored if changes in RNAP II occur during infection. Here we show that influenza virus causes the specific degradation of the hypophosphorylated form of the largest subunit of RNAP II without affecting the accumulation of its hyperphosphorylated forms. This effect is independent of the viral strain and the origin of the cells used. Analysis of synthesized mRNAs in isolated nuclei of infected cells indicated that transcription decreases concomitantly with RNAP II degradation. Moreover, this degradation correlated with the onset of viral transcription and replication. The ubiquitin-mediated proteasome pathway is not involved in virally induced RNAP II proteolysis. The expression of viral polymerase from its cloned cDNAs was sufficient to cause the degradation. Since the PA polymerase subunit has proteolytic activity, we tested its participation in the process. A recombinant virus that encodes a PA point mutant with decreased proteolytic activity and that has defects in replication delayed the effect, suggesting that PA's contribution to RNAP II degradation occurs during infection.
Collapse
|
38
|
Rodríguez-Cervantes PJ, Sancho-Bru JL, Barjau-Escribano A, Forner-Navarro L, Pérez-González A, Sánchez-Marín FT. Influence of prefabricated post dimensions on restored maxillary central incisors. J Oral Rehabil 2007; 34:141-52. [PMID: 17244237 DOI: 10.1111/j.1365-2842.2006.01720.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to develop a model of the restored tooth. The post diameter had a significant effect on the biomechanical performance of teeth restored with stainless steel posts. Lower failure loads were found as post diameter increased. However, the post diameter of those teeth restored with glass fibre posts, and the post length for both post systems under consideration, did not affect the biomechanical performance of restored teeth to a significant degree. The stress distributions predicted by the developed model corroborated these findings, confirmed the assumed hypothesis, and permitted the proposal of the use of glass fibre posts to achieve a restorative technique that is less sensitive to post dimensions, and thus more robust.
Collapse
|
39
|
Carbonell E, Bermúdez de Castro JM, Arsuaga JL, Allue E, Bastir M, Benito A, Cáceres I, Canals T, Díez JC, van der Made J, Mosquera M, Ollé A, Pérez-González A, Rodríguez J, Rodríguez XP, Rosas A, Rosell J, Sala R, Vallverdú J, Vergés JM. An Early Pleistocene hominin mandible from Atapuerca-TD6, Spain. Proc Natl Acad Sci U S A 2005; 102:5674-8. [PMID: 15824320 PMCID: PMC556125 DOI: 10.1073/pnas.0501841102] [Citation(s) in RCA: 137] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
We present a mandible recovered in 2003 from the Aurora Stratum of the TD6 level of the Gran Dolina site (Sierra de Atapuerca, northern Spain). The specimen, catalogued as ATD6-96, adds to the hominin sample recovered from this site in 1994-1996, and assigned to Homo antecessor. ATD6-96 is the left half of a gracile mandible belonging to a probably female adult individual with premolars and molars in place. This mandible shows a primitive structural pattern shared with all African and Asian Homo species. However, it is small and exhibits a remarkable gracility, a trait shared only with the Early and Middle Pleistocene Chinese hominins. Furthermore, none of the mandibular features considered apomorphic in the European Middle and Early Upper Pleistocene hominin lineage are present in ATD6-96. This evidence reinforces the taxonomic identity of H. antecessor and is consistent with the hypothesis of a close relationship between this species and Homo sapiens.
Collapse
|
40
|
Abstract
The ideal diameter for a tool handle for males and females has been determined using an existing biomechanical model of the hand validated in previous works. The model estimates a 33-mm optimum diameter tool handle for the general population (males and females). When the optimum diameter for a tool handle is selected, the muscles exert the minimum force needed to hold the tool and perform gripping activities. Optimal handle design reduces the force required for gripping a tool, protects the underlying joint structures, and reduces the risk of developing cumulative trauma associated with repetitive task requiring high grip forces and awkward postures. This article provides a design parameter for optimal tool diameter to aid the therapist in the selection of assistive devices, built-up handles, or for the fabrication of a tool handle.
Collapse
|
41
|
Vergara M, Sancho-Bru JL, Pérez-González A. Description and Validation of a Non-Invasive Technique to Measure the Posture of All Hand Segments. J Biomech Eng 2004; 125:917-22. [PMID: 14986420 DOI: 10.1115/1.1635403] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The aim of this work is to describe and validate a technique for measuring the posture of all the segments of the hand in a non-invasive way. The technique uses digital photographic images to reconstruct 3-D location of markers drawn on the skin. The markers are defined to obtain joint rotation angles with physiological meaning. Different experiments have been developed in order to analyze the accuracy and repeatability of the angle measurements. Although the placement of markers does not require any special care, the errors due to their location are lower than 2.6 deg in all cases, thus assuring the repeatability of the technique.
Collapse
|
42
|
González-Manteiga W, Pérez-González A. Nonparametric Mean Estimation with Missing Data. COMMUN STAT-THEOR M 2004. [DOI: 10.1081/sta-120028374] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
43
|
Sancho-Bru JL, Pérez-González A, Vergara M, Giurintano DJ. A 3D biomechanical model of the hand for power grip. J Biomech Eng 2003; 125:78-83. [PMID: 12661199 DOI: 10.1115/1.1532791] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A three-dimensional scalable biomechanical model of the four fingers of the hand to evaluate power grip is proposed. The model has been validated by means of reproducing an experiment in which the subjects exerted the maximal voluntary grasping force over cylinders of different diameters. The model is used to simulate the cylinder grip for two hand sizes and for five different handle diameters. The reduction of the muscle forces using different handle diameters has been studied. The model can be applied to the design and evaluation of handles for power grip and to the study of power grasp for normal and abnormal hands.
Collapse
|
44
|
Sancho-Bru JL, Pérez-González A, Vergara-Monedero M, Giurintano D. A 3-D dynamic model of human finger for studying free movements. J Biomech 2001; 34:1491-500. [PMID: 11672724 DOI: 10.1016/s0021-9290(01)00106-3] [Citation(s) in RCA: 102] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The purpose of this work is to develop a 3D inverse dynamic model of the human finger for estimating the muscular forces involved during free finger movements. A review of the existing 3D models of the fingers is presented, and an alternative one is proposed. The validity of the model has been proved by means of two simulations: free flexion-extension motion of all joints, and free metacarpophalangeal (MCP) adduction motion. The simulation shows the need for a dynamic model including inertial effects when studying fast movements and the relevance of modelling passive forces generated by the structures studying free movements, such as the force exerted by the muscles when they are stretched and the passive action of the ligaments over the MCP joint in order to reproduce the muscular force pattern during the simulation of the free MCP abduction-adduction movements.
Collapse
|
45
|
Parés JM, Pérez-González A, Weil AB, Arsuaga JL. On the age of the hominid fossils at the Sima de los Huesos, Sierra de Atapuerca, Spain: paleomagnetic evidence. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2000; 111:451-61. [PMID: 10727965 DOI: 10.1002/(sici)1096-8644(200004)111:4<451::aid-ajpa2>3.0.co;2-j] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We report new paleomagnetic data for the Middle Pleistocene hominid-bearing strata in the Sima de los Huesos, North Spain. Sediments (brown muds with human and bear fossils and the underlying sterile clayey and sandy unit) preserve both normal and reversed magnetic components. The sterile unit has exclusively reversed magnetization, dating back to the Matuyama Chron, and thus is Lower Pleistocene in age. The overlying fossiliferous muds have a dominant normal magnetization that overprints a partially resolved reversed magnetization. These data are compatible with one of the reversal events that occurred during the Brunhes Chron. Combined with the existing U-series dates and evidence from the macro- and microfauna, these paleomagnetic results suggest an age of the hominid fossils between 325 to 205 ka, whereas the underlying sand and silts are older than 780 ka.
Collapse
|
46
|
Parés JM, Pérez-González A. Magnetochronology and stratigraphy at Gran Dolina section, Atapuerca (Burgos, Spain). J Hum Evol 1999; 37:325-42. [PMID: 10496990 DOI: 10.1006/jhev.1999.0331] [Citation(s) in RCA: 173] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The Atapuerca Site (Burgos, N. Spain) is an extensive archaeological site which has yielded numerous human fossil remains. The Gran Dolina section, one of the open-air excavations and subject of this study, consists of a sedimentary infilling of 18 m thickness in a gallery originated by karstification of the host Cretaceous limestones. In this paper we present new stratigraphic and paleomagnetic evidence for the age and the sedimentary environment of the karst infilling where the archaeological site is located. Paleomagnetic dating places the hominids (Aurora stratum) in the Matuyama reversed Chron, hence before 780 ka. We also report evidence for a short normal polarity event at the bottom of the section that we speculate as being Jaramillo or Kamikatsura. The early and well-constrained date of the Atapuerca archaeological site, its location in the cul-de-sac we know as Europe, its stratigraphic context, the abundant fossil remains and the stone tool industry make it one of the most important localities for the question of the earliest human occupation in Europe.
Collapse
|
47
|
Pérez-González A. Pauli limiting of the upper critical magnetic field for d-wave superconductors. PHYSICAL REVIEW. B, CONDENSED MATTER 1996; 54:16053-16057. [PMID: 9985677 DOI: 10.1103/physrevb.54.16053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
48
|
|
49
|
Parés JM, Pérez-González A. Paleomagnetic age for hominid fossils at Atapuerca archaeological site, Spain. Science 1995; 269:830-2. [PMID: 7638599 DOI: 10.1126/science.7638599] [Citation(s) in RCA: 182] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
A paleomagnetic investigation at the Gran Dolina site excavation (Atapuerca, Spain) shows that the sediments containing the recently discovered human occupation were deposited more than 780,000 years ago, near the time of the Matuyama-Brunhes boundary. Forty-one oriented samples were obtained from 22 sites along an 18-meter section of the Gran Dolina karst filling. The lower 16 sites displayed reversed-polarity magnetizations whereas the upper six sites were normal. The reversal spans the hominid finds at stratigraphic level TD6 (the Aurora stratum), and these hominid fossils are therefore the oldest in southern Europe.
Collapse
|
50
|
Pérez-González A, Carbotte JP. Upper critical magnetic field of d-wave superconductors: Pauli limiting. PHYSICAL REVIEW. B, CONDENSED MATTER 1992; 45:9894-9899. [PMID: 10000880 DOI: 10.1103/physrevb.45.9894] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|