Greim CA, Roewer N, Apfel C, Laux G, Schulte am Esch J. Relation of echocardiographic preload indices to stroke volume in critically ill patients with normal and low cardiac index.
Intensive Care Med 1997;
23:411-6. [PMID:
9142580 DOI:
10.1007/s001340050349]
[Citation(s) in RCA: 29] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE
To examine the usefulness of preload indices obtained by transoesophageal echocardiography (TOE) for estimating stroke volume at various levels of cardiac index.
DESIGN
Prospective clinical study.
SETTING
Intensive care unit with surgical patients.
PATIENTS
16 ventilated patients monitored via Swan-Ganz catheterization and TOE.
INTERVENTIONS
Echocardiographic images of left ventricular cross-sectional short-axis areas were analysed for the preload indices end-diastolic area (EDA), stroke area and end-diastolic wall stress. The relation between these indices and stroke volume, calculated from thermodilution cardiac output, was analysed in all patients and in nine patient groups discriminated by various ranges in heart rate (< or = 70 to > 110 beats/min), pulmonary artery occlusion pressure (< or = 8 to > 12 mmHg) and cardiac index (< or = 3.0 to > 4.2 l/min per m2).
MEASUREMENTS AND RESULTS
Overall stroke volume (n = 155) correlated significantly (p < 0.0001) with EDA (r = 0.89) and stroke area (r = 0.80). The correlation with end-diastolic wall stress was non-significant (r = 0.51). Linearity in the relation between stroke volume and EDA or stroke area was independent of variations in heart rate and pulmonary artery occlusion pressure. Stroke volume correlated well with EDA and stroke area, when cardiac index was normal or high, but the relation slightly deteriorated (r = 0.63 to < or = 0.72) when the cardiac index was low. Changes in EDA and stroke area by more than 1, 2 or 3 cm2 were weak predictors for changes in stroke volume greater than 20%.
CONCLUSIONS
Stability of the relation between echocardiographic preload indices and stroke volume emphasize the potential of TOE for continuous preload monitoring in the critically ill.