26
|
Thom I, Cameron G, Robertson D, Watson HG. Measurement of rivaroxaban concentrations demonstrates lack of clinical utility of a PT, dPT and APTT test in estimating levels. Int J Lab Hematol 2018; 40:493-499. [PMID: 29718586 DOI: 10.1111/ijlh.12846] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2018] [Accepted: 03/14/2018] [Indexed: 01/02/2023]
Abstract
INTRODUCTION Rivaroxaban concentrations were measured in 127 inpatient samples using an HPLC-MS/MS assay. METHODS We compared this measurement with a calibrated anti-Xa assay and performed PT, aPTT and dilute PT tests to assess the value of clot-based assays in clinical decision-making. RESULTS The correlation between the anti-Xa assay and the HPLC-MS/MS at therapeutic concentrations was strong (R2 = 0.98). The PT, RecombiPlasTin 2G, and aPTT, Actin FS, showed a linear dose-response but poor correlation (R2 = 0.32 and 0.44, respectively) and at dilutions of 1 in 150 to 1 in 750 the dilute PT assay also showed poor correlation with rivaroxaban concentrations measured by specific assays. A normal PT or aPTT alone did not identify a likely safe rivaroxaban concentration to allow surgery or invasive procedures, but the combination of normal PT and aPTT identified a group of patients with rivaroxaban levels less than 90 ng/mL. Combined normal PT and aPTT had specificity and sensitivity of 0.97 (95% CI 0.92-0.99) and 0.37 (95% CI 0.1-0.74) for a rivaroxaban concentration < 32 ng/mL. CONCLUSIONS The PT and aPTT show poor correlation with rivaroxaban levels measured by calibrated anti-Xa and HPLC-MS/MS assays. A normal combined PT and APTT identified low rivaroxaban levels with high specificity but lacked sensitivity. The dPT assay at several dilutions could not be used to quantify rivaroxaban in clinical samples. The utility of these PT, aPTT and dilute PT assays in a clinical setting is very limited, and results generated must be interpreted with caution.
Collapse
|
27
|
Alsanea F, Darne C, Robertson D, Beddar S. OC-0083: Light yield and ionization quenching measurements of the 3D scintillator detector for proton therapy. Radiother Oncol 2018. [DOI: 10.1016/s0167-8140(18)30393-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
28
|
Fang X, Tan WP, Beard M, deBoer RJ, Gilardy G, Jung H, Liu Q, Lyons S, Robertson D, Setoodehnia K, Seymour C, Stech E, Vande Kolk B, Wiescher M, de Souza R, Hudan S, Singh V, Tang XD, Uberseder E. Experimental measurement of the 12C+ 16O fusion cross sections at astrophysical energies. EPJ WEB OF CONFERENCES 2018. [DOI: 10.1051/epjconf/201817804008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The total cross sections of the 12C+16O fusion have been experimentally determined at low energies to investigate the role of this reaction during late stellar evolution burning phases. A high-intensity oxygen beam was produced by the 5MV pelletron accelerator at the University of Notre Dame impinging on a thick ultra-pure graphite target. Protons and γ-rays were measured simultaneously in the center-of-mass energy range from 3.64 to 5.01 MeV, using strip silicon and HPGe detectors. Statistical model calculations were employed to interpret the experimental results. A new broad resonance-like structure is observed for the 12C+16O reaction, and a decreasing trend of its S-factor towards low energies is found.
Collapse
|
29
|
Nicholas JR, Ireland PT, Hancock D, Robertson D. Manufacture and Initial Thermo-Fluid Measurements on a Heat Sink Module for Potential Applications in a DEMO. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.1080/15361055.2017.1350483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
30
|
Yeung G, Frecker H, Kives S, Robertson D. Measures to Reduce Peri- and Intra-Operative Blood Loss at Myomectomy: a Survey of Obstetrician-Gynecologists. J Minim Invasive Gynecol 2017. [DOI: 10.1016/j.jmig.2017.08.207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
31
|
Barry K, Robertson D, Mulders W. Medial geniculate neurons show diverse effects in response to electrical stimulation of prefrontal cortex. Hear Res 2017; 353:204-212. [DOI: 10.1016/j.heares.2017.07.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 06/07/2017] [Accepted: 07/06/2017] [Indexed: 01/04/2023]
|
32
|
Robertson D, Weiss D. CAN COUNTER STEREOTYPES CHANGE PERCEPTIONS OF OLDER ADULTS’ SOCIAL STATUS? Innov Aging 2017. [DOI: 10.1093/geroni/igx004.3370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
33
|
Ziri H, Robertson D, Beddar S. OC-0061: Development of a 3D plastic Scintillator detector for a fast verification of ocular proton beam. Radiother Oncol 2017. [DOI: 10.1016/s0167-8140(17)30505-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
34
|
Hawkins L, Frecker H, Sholzberg M, Robertson D. Perioperative Blood Loss and Transfusion Risk Factors During Abdominal Myomectomy. J Minim Invasive Gynecol 2016. [DOI: 10.1016/j.jmig.2016.08.671] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
35
|
Ashwood KL, Gillan N, Horder J, Hayward H, Woodhouse E, McEwen FS, Findon J, Eklund H, Spain D, Wilson CE, Cadman T, Young S, Stoencheva V, Murphy CM, Robertson D, Charman T, Bolton P, Glaser K, Asherson P, Simonoff E, Murphy DG. Predicting the diagnosis of autism in adults using the Autism-Spectrum Quotient (AQ) questionnaire. Psychol Med 2016; 46:2595-2604. [PMID: 27353452 PMCID: PMC4988267 DOI: 10.1017/s0033291716001082] [Citation(s) in RCA: 102] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 04/18/2016] [Accepted: 04/21/2016] [Indexed: 01/22/2023]
Abstract
BACKGROUND Many adults with autism spectrum disorder (ASD) remain undiagnosed. Specialist assessment clinics enable the detection of these cases, but such services are often overstretched. It has been proposed that unnecessary referrals to these services could be reduced by prioritizing individuals who score highly on the Autism-Spectrum Quotient (AQ), a self-report questionnaire measure of autistic traits. However, the ability of the AQ to predict who will go on to receive a diagnosis of ASD in adults is unclear. METHOD We studied 476 adults, seen consecutively at a national ASD diagnostic referral service for suspected ASD. We tested AQ scores as predictors of ASD diagnosis made by expert clinicians according to International Classification of Diseases (ICD)-10 criteria, informed by the Autism Diagnostic Observation Schedule-Generic (ADOS-G) and Autism Diagnostic Interview-Revised (ADI-R) assessments. RESULTS Of the participants, 73% received a clinical diagnosis of ASD. Self-report AQ scores did not significantly predict receipt of a diagnosis. While AQ scores provided high sensitivity of 0.77 [95% confidence interval (CI) 0.72-0.82] and positive predictive value of 0.76 (95% CI 0.70-0.80), the specificity of 0.29 (95% CI 0.20-0.38) and negative predictive value of 0.36 (95% CI 0.22-0.40) were low. Thus, 64% of those who scored below the AQ cut-off were 'false negatives' who did in fact have ASD. Co-morbidity data revealed that generalized anxiety disorder may 'mimic' ASD and inflate AQ scores, leading to false positives. CONCLUSIONS The AQ's utility for screening referrals was limited in this sample. Recommendations supporting the AQ's role in the assessment of adult ASD, e.g. UK NICE guidelines, may need to be reconsidered.
Collapse
|
36
|
Darne C, Robertson D, Alsanea F, Beddar S. SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras. Med Phys 2016. [DOI: 10.1118/1.4955626] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
37
|
Robertson D, Zhao Z, Wang X, Yang J. SU-F-T-515: Increased Skin Dose in Supine Craniospinal Irradiation Due to Carbon Fiber Couch and Vacuum Bag Immobilization Device. Med Phys 2016. [DOI: 10.1118/1.4956700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
38
|
Mulders WHAM, Spencer TC, Robertson D. Effects of pulsatile electrical stimulation of the round window on central hyperactivity after cochlear trauma in guinea pig. Hear Res 2016; 335:128-137. [PMID: 26970475 DOI: 10.1016/j.heares.2016.03.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 02/09/2016] [Accepted: 03/03/2016] [Indexed: 11/17/2022]
Abstract
Partial hearing loss induced by acoustic trauma has been shown in animal models to result in an increased spontaneous firing rate in central auditory structures. This so-called hyperactivity has been suggested to be involved in the generation of tinnitus, a phantom auditory sensation. Although there is no universal cure for tinnitus, electrical stimulation of the cochlea, as achieved by a cochlear implant, can result in significant reduction of the tinnitus percept. However, the mechanism by which this tinnitus suppression occurs is as yet unknown and furthermore cochlear implantation may not be an optimal treatment option for tinnitus sufferers who are not profoundly deaf. A better understanding of the mechanism of tinnitus suppression by electrical stimulation of the cochlea, may lead to the development of more specialised devices for those for whom a cochlear implant is not appropriate. This study aimed to investigate the effects of electrical stimulation in the form of brief biphasic shocks delivered to the round window of the cochlea on the spontaneous firing rates of hyperactive inferior colliculus neurons following acoustic trauma in guinea pigs. Effects during the stimulation itself included both inhibition and excitation but spontaneous firing was suppressed for up to hundreds of ms after the cessation of the shock train in all sampled hyperactive neurons. Pharmacological block of olivocochlear efferent action on outer hair cells did not eliminate the prolonged suppression observed in inferior colliculus neurons, and it is therefore likely that activation of the afferent pathways is responsible for the central effects observed.
Collapse
|
39
|
Ahire JJ, Robertson D, Neveling DP, van Reenen AJ, Dicks LMT. Hyaluronic acid-coated poly(d,l-lactide) (PDLLA) nanofibers prepared by electrospinning and coating. RSC Adv 2016. [DOI: 10.1039/c6ra01996j] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Process of preparation of HA/PDLLA nanohybrids.
Collapse
|
40
|
Tang X, Bucher B, Fang X, Heger A, Almaraz-Calderon S, Alongi A, Ayangeakaa A, Beard M, Best A, Browne J, Cahillane C, Couder M, deBoer R, Kontos A, Lamm L, Li Y, Long A, Lu W, Lyons S, Notani M, Patel D, Paul N, Pignatari M, Roberts A, Robertson D, Smith K, Stech E, Talwar R, Tan W, Wiescher M, Woosley S. First direct measurement of 12C( 12C,n) 23Mg at stellar energies. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201610904009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
41
|
Barry K, Paolini A, Robertson D, Mulders W. Modulation of medial geniculate nucleus neuronal activity by electrical stimulation of the nucleus accumbens. Neuroscience 2015; 308:1-10. [DOI: 10.1016/j.neuroscience.2015.09.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2015] [Revised: 08/19/2015] [Accepted: 09/02/2015] [Indexed: 01/03/2023]
|
42
|
Hobson R, Farmer AD, Dewit OE, O'Donnell M, Hacquoil K, Robertson D, Barton ME, Dukes GE. The effects of camicinal, a novel motilin agonist, on gastro-esophageal function in healthy humans-a randomized placebo controlled trial. Neurogastroenterol Motil 2015; 27:1629-37. [PMID: 26348542 DOI: 10.1111/nmo.12663] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Accepted: 07/29/2015] [Indexed: 12/22/2022]
Abstract
BACKGROUND A proportion of patients with foregut dysmotility fail to respond to standard interventions. Motilin agonists may be beneficial in this group. We aimed to determine the effect of camicinal, a novel motilin agonist, on gastrointestinal physiology in healthy volunteers. METHODS Healthy male subjects were randomly assigned to receive a single dose of 125 mg camicinal or placebo in a double-blind cross-over design. Esophageal function and reflux indices were assessed using high-resolution manometry (pre and 1.5-h post dose) and 24-h ambulatory multichannel intraluminal impedance/pH. After a standardized meal, subjects ingested a wireless motility capsule from which compartmental transit times and motility indices were derived. Subjects were restudied with the alternate intervention after 7 days. KEY RESULTS The study subjects (12 male, mean age 47.4 years, range 22-55) tolerated the drug well, except one who exhibited mild abdominal pain on both placebo and camicinal. In comparison to placebo, gastric emptying time (GET) was accelerated following camicinal (-115.4 min, 95% confidence interval -194.4, -36.4, p = 0.009). No effect was demonstrable on esophageal function, small bowel, colonic, or whole bowel transit times and motility indices. With camicinal, as part of a post hoc analysis, there was a trend association between the percentage reduction in GET and total number of acidic reflux events (r = 0.56, p = 0.09). CONCLUSIONS & INFERENCES Camicinal decreases GET and was generally well-tolerated. In health, the direct effects of camicinal are on accelerating GET with a potential secondary benefit of reducing reflux events, which warrant further exploration in patient cohorts.
Collapse
|
43
|
Henry T, Robertson D, Therriault-Proulx F, Beddar S. MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector. Med Phys 2015. [DOI: 10.1118/1.4925478] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
44
|
Suh Y, Hui C, Robertson D, Pan T, Das P, Crane C, Beddar S. SU-E-J-157: Comparison Between Internal Respiratory Signal and External Respiratory Signal in 4D CT. Med Phys 2015. [DOI: 10.1118/1.4924242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
45
|
Hui C, Robertson D, Alsanea F, Beddar S. SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector. Med Phys 2015. [DOI: 10.1118/1.4925004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
46
|
Robertson D, Sahoo N, Beddar S. TH-CD-BRA-09: Quality Assurance of Scanned Proton Beams with a Volumetric Liquid Scintillator Detector. Med Phys 2015. [DOI: 10.1118/1.4926234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
47
|
Nitsch P, Robertson D, Balter P. SU-E-J-14: A Comparison of a 2.5MV Imaging Beam to KV and 6MV Imaging Beams. Med Phys 2015. [DOI: 10.1118/1.4924102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
48
|
Paunicka KJ, Mellon J, Robertson D, Petroll M, Brown JR, Niederkorn JY. Severing corneal nerves in one eye induces sympathetic loss of immune privilege and promotes rejection of future corneal allografts placed in either eye. Am J Transplant 2015; 15:1490-501. [PMID: 25872977 PMCID: PMC4590984 DOI: 10.1111/ajt.13240] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2014] [Revised: 11/16/2014] [Accepted: 12/06/2014] [Indexed: 01/25/2023]
Abstract
Less than 10% of corneal allografts undergo rejection even though HLA matching is not performed. However, second corneal transplants experience a threefold increase in rejection, which is not due to prior sensitization to histocompatibility antigens shared by the first and second transplants since corneal grafts are selected at random without histocompatibility matching. Using a mouse model of penetrating keratoplasty, we found that 50% of the initial corneal transplants survived, yet 100% of the subsequent corneal allografts (unrelated to the first graft) placed in the opposite eye underwent rejection. The severing of corneal nerves that occurs during surgery induced substance P (SP) secretion in both eyes, which disabled T regulatory cells that are required for allograft survival. Administration of an SP antagonist restored immune privilege and promoted graft survival. Thus, corneal surgery produces a sympathetic response that permanently abolishes immune privilege of subsequent corneal allografts, even those placed in the opposite eye and expressing a completely different array of foreign histocompatibility antigens from the first corneal graft.
Collapse
|
49
|
Bucher B, Fang X, Tang X, Tan W, Almaraz-Calderon S, Alongi A, Ayangeakaa A, Beard M, Best A, Browne J, Cahillane C, Couder M, Dahlstrom E, Davies P, deBoer R, Kontos A, Lamm L, Long A, Lu W, Lyons S, Ma C, Moncion A, Notani M, Patel D, Paul N, Pignatari M, Roberts A, Robertson D, Smith K, Stech E, Talwar R, Thomas S, Wiescher M. Constraining the 12C+ 12C fusion cross section for astrophysics. EPJ WEB OF CONFERENCES 2015. [DOI: 10.1051/epjconf/20159303009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
50
|
Noreña AJ, Mulders WHAM, Robertson D. Suppression of putative tinnitus-related activity by extra-cochlear electrical stimulation. J Neurophysiol 2015; 113:132-43. [DOI: 10.1152/jn.00580.2014] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Studies on animals have shown that noise-induced hearing loss is followed by an increase of spontaneous firing at several stages of the central auditory system. This central hyperactivity has been suggested to underpin the perception of tinnitus. It was shown that decreasing cochlear activity can abolish the noise-induced central hyperactivity. This latter result further suggests that an approach consisting of reducing cochlear activity may provide a therapeutic avenue for tinnitus. In this context, extra-cochlear electric stimulation (ECES) may be a good candidate to modulate cochlear activity and suppress tinnitus. Indeed, it has been shown that a positive current applied at the round window reduces cochlear nerve activity and can suppress tinnitus reliably in tinnitus subjects. The present study investigates whether ECES with a positive current can abolish the noise-induced central hyperactivity, i.e., the putative tinnitus-related activity. Spontaneous and stimulus-evoked neural activity before, during and after ECES was assessed from single-unit recordings in the inferior colliculus of anesthetized guinea pigs. We found that ECES with positive current significantly decreases the spontaneous firing rate of neurons with high characteristic frequencies, whereas negative current produces the opposite effect. The effects of the ECES are absent or even reversed for neurons with low characteristic frequencies. Importantly, ECES with positive current had only a marginal effect on thresholds and tone-induced activity of collicular neurons, suggesting that the main action of positive current is to modulate the spontaneous firing. Overall, cochlear electrical stimulation may be a viable approach for suppressing some forms of (peripheral-dependent) tinnitus.
Collapse
|