Chapman CAR, Aristovich K, Donega M, Fjordbakk CT, Stathopoulou TR, Viscasillas J, Avery J, Perkins JD, Holder D. Electrode fabrication and interface optimization for imaging of evoked peripheral nervous system activity with electrical impedance tomography (EIT). J Neural Eng 2018; 16:016001. [PMID: 30444215 DOI: 10.1088/1741-2552/aae868] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE Non-invasive imaging techniques are undoubtedly the ideal methods for continuous monitoring of neural activity. One such method, fast neural electrical impedance tomography (EIT) has been developed over the past decade in order to image neural action potentials with non-penetrating electrode arrays. APPROACH The goal of this study is two-fold. First, we present a detailed fabrication method for silicone-based multiple electrode arrays which can be used for epicortical or neural cuff applications. Secondly, we optimize electrode material coatings in order to achieve the best accuracy in EIT reconstructions. MAIN RESULTS The testing of nanostructured electrode interface materials consisting of platinum, iridium oxide, and PEDOT:pTS in saline tank experiments demonstrated that the PEDOT:pTS coating used in this study leads to more accurate reconstruction dimensions along with reduced phase separation between recording channels. The PEDOT:pTS electrodes were then used in vivo to successfully image and localize the evoked activity of the recurrent laryngeal fascicle from within the cervical vagus nerve. SIGNIFICANCE These results alongside the simple fabrication method presented here position EIT as an effective method to image neural activity.
Collapse
|
27
|
Hannan S, Faulkner M, Aristovich K, Avery J, Walker M, Holder D. Imaging fast electrical activity in the brain during ictal epileptiform discharges with electrical impedance tomography. NEUROIMAGE-CLINICAL 2018; 20:674-684. [PMID: 30218899 PMCID: PMC6140294 DOI: 10.1016/j.nicl.2018.09.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 07/27/2018] [Accepted: 09/02/2018] [Indexed: 12/19/2022]
Abstract
Electrical Impedance Tomography (EIT) is an emerging medical imaging technique which can produce tomographic images of internal impedance changes within an object using non-penetrating surface electrodes. It has previously been used to image impedance changes due to neuronal depolarisation during evoked potentials in the rat somatosensory cortex with a resolution of 2 ms and <200 μm, using an epicortical electrode array. The purpose of this work was to use this technique to elucidate the intracortical spatiotemporal trajectory of ictal spike-and-wave discharges (SWDs), induced by electrical stimulation in an acute rat model of epilepsy, throughout the cerebral cortex. Seizures lasting 16.5 ± 5.3 s with repetitive 2-5 Hz SWDs were induced in five rats anaesthetised with fentanyl-isoflurane. Transfer impedance measurements were obtained during each seizure with a 57-electrode epicortical array by applying 50 μA current at 1.7 kHz to two electrodes and recording voltages from all remaining electrodes. Images were reconstructed from averaged SWD-related impedance traces obtained from EIT measurements in successive seizures. We report the occurrence of reproducible impedance changes during the initial spike phase, which had an early onset in the whisker barrel cortex and spread posteriorly, laterally and ventrally over 20 ms (p < 0.03125, N = 5). These findings, which confirm and extend knowledge of SWD initiation and expression, suggest that EIT is a valuable neuroimaging tool for improving understanding of neural circuits implicated in epileptic phenomena.
Collapse
|
28
|
Faulkner M, Hannan S, Aristovich K, Avery J, Holder D. Feasibility of imaging evoked activity throughout the rat brain using electrical impedance tomography. Neuroimage 2018; 178:1-10. [DOI: 10.1016/j.neuroimage.2018.05.022] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 04/26/2018] [Accepted: 05/08/2018] [Indexed: 10/16/2022] Open
|
29
|
Aristovich K, Donegá M, Blochet C, Avery J, Hannan S, Chew DJ, Holder D. Imaging fast neural traffic at fascicular level with electrical impedance tomography: proof of principle in rat sciatic nerve. J Neural Eng 2018; 15:056025. [DOI: 10.1088/1741-2552/aad78e] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
30
|
Hannan S, Faulkner M, Aristovich K, Avery J, Holder D. Frequency-dependent characterisation of impedance changes during epileptiform activity in a rat model of epilepsy. Physiol Meas 2018; 39:085003. [DOI: 10.1088/1361-6579/aad5f4] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
31
|
Acheampong C, Davis C, Holder D, Averett P, Savitt T, Campbell K. An Exploratory Study of Stress Coping and Resiliency of Black Men at One Medical School: A Critical Race Theory Perspective. J Racial Ethn Health Disparities 2018; 6:214-219. [DOI: 10.1007/s40615-018-0516-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 07/05/2018] [Accepted: 07/10/2018] [Indexed: 11/30/2022]
|
32
|
Goren N, Avery J, Dowrick T, Mackle E, Witkowska-Wrobel A, Werring D, Holder D. Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients. Sci Data 2018; 5:180112. [PMID: 29969115 PMCID: PMC6029572 DOI: 10.1038/sdata.2018.112] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Accepted: 04/16/2018] [Indexed: 11/26/2022] Open
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which has the potential to expedite the differentiation of ischaemic or haemorrhagic stroke, decreasing the time to treatment. Whilst demonstrated in simulation, there are currently no suitable imaging or classification methods which can be successfully applied to human stroke data. Development of these complex methods is hindered by a lack of quality Multi-Frequency EIT (MFEIT) data. To address this, MFEIT data were collected from 23 stroke patients, and 10 healthy volunteers, as part of a clinical trial in collaboration with the Hyper Acute Stroke Unit (HASU) at University College London Hospital (UCLH). Data were collected at 17 frequencies between 5 Hz and 2 kHz, with 31 current injections, yielding 930 measurements at each frequency. This dataset is the most comprehensive of its kind and enables combined analysis of MFEIT, Electroencephalography (EEG) and Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) data in stroke patients, which can form the basis of future research into stroke classification.
Collapse
|
33
|
Tarotin I, Aristovich K, Holder D. Model of Impedance Changes in Unmyelinated Nerve Fibers. IEEE Trans Biomed Eng 2018; 66:471-484. [PMID: 29993457 DOI: 10.1109/tbme.2018.2849220] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Currently, there is no imaging method that is able to distinguish the functional activity inside nerves. Such a method would be essential for understanding peripheral nerve physiology and would allow precise neuromodulation of organs these nerves supply. Electrical impedance tomography (EIT) is a method that produces images of electrical impedance change (dZ) of an object by injecting alternating current and recording surface voltages. It has been shown to be able to image fast activity in the brain and large peripheral nerves. To image inside small autonomic nerves, mostly containing unmyelinated fibers, it is necessary to maximize SNR and optimize the EIT parameters. An accurate model of the nerve is required to identify these optimal parameters as well as to validate data obtained in the experiments. METHODS In this study, we developed two three-dimensional models of unmyelinated fibers: Hodgkin-Huxley (HH) squid giant axon (single and multiple) and mammalian C-nociceptor. A coupling feedback system was incorporated into the models to simulate direct and alternating current application and simultaneously record external field during action potential propagation. RESULTS Parameters of the developed models were varied to study their influence on the recorded impedance changes; the optimal parameters were identified. The negative dZ was found to monotonically decrease with frequency for both HH and C fiber models, in accordance with the experimental data. CONCLUSION AND SIGNIFICANCE The accurate realistic model of unmyelinated nerve allows the optimization of EIT parameters and matches literature and experimental results.
Collapse
|
34
|
Witkowska-Wrobel A, Aristovich K, Faulkner M, Avery J, Holder D. Feasibility of imaging epileptic seizure onset with EIT and depth electrodes. Neuroimage 2018; 173:311-321. [DOI: 10.1016/j.neuroimage.2018.02.056] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 02/22/2018] [Accepted: 02/26/2018] [Indexed: 11/27/2022] Open
|
35
|
Aristovich K, Donega M, Avery J, Chew D, Holder D. F36. Imaging fascicle traffic in peripheral nerve using fast neural EIT. Clin Neurophysiol 2018. [DOI: 10.1016/j.clinph.2018.04.199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
36
|
Hannan S, Faulkner M, Aristovich K, Holder D. T16. Imaging propagation of ictal spike-and-wave activity in the cerebral cortex over milliseconds with fast neural electrical impedance tomography. Clin Neurophysiol 2018. [DOI: 10.1016/j.clinph.2018.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
37
|
Witkowska-Wrobel A, Aristovich K, Avery J, Faulkner M, Holder D. T15. Imaging fast neuronal depolarization in 3D during seizures with electrical impedance tomography and scalp and intracranial depth electrodes. Clin Neurophysiol 2018. [DOI: 10.1016/j.clinph.2018.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
38
|
Faulkner M, Hannan S, Aristovich K, Avery J, Holder D. Characterising the frequency response of impedance changes during evoked physiological activity in the rat brain. Physiol Meas 2018; 39:034007. [DOI: 10.1088/1361-6579/aab01f] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
39
|
Abstract
OBJECTIVE The most commonly used EIT paradigm (time division multiplexing) limits the temporal resolution of impedance images due to the need to switch between injection electrodes. Advances have previously been made using frequency division multiplexing (FDM) to increase temporal resolution, but in cases where a fixed range of frequencies is available, such as imaging fast neural activity, an upper limit is placed on the total number of simultaneous injections. The use of phase division multiplexing (PDM) where multiple out of phase signals can be injected at each frequency is investigated to increase temporal resolution. APPROACH TDM, FDM and PDM were compared in head tank experiments, to compare transfer impedance measurements and spatial resolution between the three techniques. A resistor phantom paradigm was established to investigate the imaging of one-off impedance changes, of magnitude 1% and with durations as low as 500 µs (similar to those seen in nerve bundles), using both PDM and TDM approaches. MAIN RESULTS In head tank experiments, a strong correlation (r > 0.85 and p < 0.001) was present between the three sets of measured transfer impedances, and no statistically significant difference was found in reconstructed image quality. PDM was able to image impedance changes down to 500 µs in the phantom experiments, while the minimum duration imaged using TDM was 5 ms. SIGNIFICANCE PDM offers a possible solution to the imaging of fast moving impedance changes (such as in nerves), where the use of triggering or coherent averaging is not possible. The temporal resolution presents an order of magnitude improvement of the TDM approach, and the approach addresses the limited spatial resolution of FDM by increasing the number of simultaneous EIT injections.
Collapse
|
40
|
Eiber C, Avery J, Holder D, McEwan A. Feasibility study of imaging fast neural activity in retinal tissue using Electrical Impedance Tomography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2017:529-532. [PMID: 29059926 DOI: 10.1109/embc.2017.8036878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Electrical Impedance Tomography has been recently applied to image fast neural activity in the somatosensory cerebral cortex. This non-invasive imaging modality has the unique advantage of high spatial-temporal resolution in millimeters over milliseconds. This work was designed to test an existing 32-channel EIT system, a modified UCL ScouseTom, and to discuss the feasibility of imaging neural activity in retinal tissue through computer simulation. The finite element method was used to model a retinal slice with a realistic conductivity-depth profile of the macaque eye. The conductivity perturbation was simulated in five different layers of the model. 5μVRMS white noise was added to boundary voltages. Simulation results showed that it is feasible to apply EIT in retinal tissue but the injection current is near threshold of unwanted phosphenes induction. Therefore the suggested future work are validating threshold current through animal experiments, developing electrodes with low contact impedance and mitigating noise through averaging.
Collapse
|
41
|
Avery J, Aristovich K, Low B, Holder D. Reproducible 3D printed head tanks for electrical impedance tomography with realistic shape and conductivity distribution. Physiol Meas 2017; 38:1116-1131. [PMID: 28530209 DOI: 10.1088/1361-6579/aa6586] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Electrical impedance tomography (EIT) has many promising applications in brain injury monitoring. To evaluate both instrumentation and reconstruction algorithms, experiments are first performed in head tanks. Existing methods, whilst accurate, produce a discontinuous conductivity, and are often made by hand, making it hard for other researchers to replicate. APPROACH We have developed a method for constructing head tanks directly in a 3D printer. Conductivity was controlled through perforations in the skull surface, which allow for saline to pass through. Varying the diameter of the holes allowed for the conductivity to be controlled with 3% error for the target conductivity range. Taking CT and MRI segmentations as a basis, this method was employed to create an adult tank with a continuous conductivity distribution, and a neonatal tank with fontanelles. MAIN RESULTS Using 3D scanning a geometric accuracy of 0.21 mm was recorded, equal to that of the precision of the 3D printer used. Differences of 6.1% ± 6.4% (n = 11 in 4 tanks) compared to simulations were recorded in c. 800 boundary voltages. This may be attributed to the morphology of the skulls increasing tortuosity effects and hole misalignment. Despite significant differences in errors between three repetitions of the neonatal tank, images of a realistic perturbation could still be reconstructed with different tanks used for the baseline and perturbation datasets. SIGNIFICANCE These phantoms can be reproduced by any researcher with access to a 'hobbyist' 3D printer in a matter of days. All design files have been released using an open source license to encourage reproduction and modification.
Collapse
|
42
|
Faulkner M, Jehl M, Aristovich K, Avery J, Witkowska-Wrobel A, Holder D. Optimisation of current injection protocol based on a region of interest. Physiol Meas 2017; 38:1158-1175. [DOI: 10.1088/1361-6579/aa69d7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
43
|
Avery J, Dowrick T, Faulkner M, Goren N, Holder D. A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System. SENSORS (BASEL, SWITZERLAND) 2017; 17:E280. [PMID: 28146122 PMCID: PMC5336119 DOI: 10.3390/s17020280] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 01/25/2017] [Indexed: 11/16/2022]
Abstract
A highly versatile Electrical Impedance Tomography (EIT) system, nicknamed the ScouseTom, has been developed. The system allows control over current amplitude, frequency, number of electrodes, injection protocol and data processing. Current is injected using a Keithley 6221 current source, and voltages are recorded with a 24-bit EEG system with minimum bandwidth of 3.2 kHz. Custom PCBs interface with a PC to control the measurement process, electrode addressing and triggering of external stimuli. The performance of the system was characterised using resistor phantoms to represent human scalp recordings, with an SNR of 77.5 dB, stable across a four hour recording and 20 Hz to 20 kHz. In studies of both haeomorrhage using scalp electrodes, and evoked activity using epicortical electrode mats in rats, it was possible to reconstruct images matching established literature at known areas of onset. Data collected using scalp electrode in humans matched known tissue impedance spectra and was stable over frequency. The experimental procedure is software controlled and is readily adaptable to new paradigms. Where possible, commercial or open-source components were used, to minimise the complexity in reproduction. The hardware designs and software for the system have been released under an open source licence, encouraging contributions and allowing for rapid replication.
Collapse
|
44
|
Jehl M, Aristovich K, Faulkner M, Holder D. Are patient specific meshes required for EIT head imaging? Physiol Meas 2016; 37:879-92. [DOI: 10.1088/0967-3334/37/6/879] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
45
|
Packham B, Barnes G, Dos Santos GS, Aristovich K, Gilad O, Ghosh A, Oh T, Holder D. Empirical validation of statistical parametric mapping for group imaging of fast neural activity using electrical impedance tomography. Physiol Meas 2016; 37:951-67. [PMID: 27203477 PMCID: PMC5717540 DOI: 10.1088/0967-3334/37/6/951] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Electrical impedance tomography (EIT) allows for the reconstruction of internal conductivity from surface measurements. A change in conductivity occurs as ion channels open during neural activity, making EIT a potential tool for functional brain imaging. EIT images can have >10 000 voxels, which means statistical analysis of such images presents a substantial multiple testing problem. One way to optimally correct for these issues and still maintain the flexibility of complicated experimental designs is to use random field theory. This parametric method estimates the distribution of peaks one would expect by chance in a smooth random field of a given size. Random field theory has been used in several other neuroimaging techniques but never validated for EIT images of fast neural activity, such validation can be achieved using non-parametric techniques. Both parametric and non-parametric techniques were used to analyze a set of 22 images collected from 8 rats. Significant group activations were detected using both techniques (corrected p < 0.05). Both parametric and non-parametric analyses yielded similar results, although the latter was less conservative. These results demonstrate the first statistical analysis of such an image set and indicate that such an analysis is an approach for EIT images of neural activity.
Collapse
|
46
|
Jehl M, Holder D. Correction of electrode modelling errors in multi-frequency EIT imaging. Physiol Meas 2016; 37:893-903. [PMID: 27206237 DOI: 10.1088/0967-3334/37/6/893] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The differentiation of haemorrhagic from ischaemic stroke using electrical impedance tomography (EIT) requires measurements at multiple frequencies, since the general lack of healthy measurements on the same patient excludes time-difference imaging methods. It has previously been shown that the inaccurate modelling of electrodes constitutes one of the largest sources of image artefacts in non-linear multi-frequency EIT applications. To address this issue, we augmented the conductivity Jacobian matrix with a Jacobian matrix with respect to electrode movement. Using this new algorithm, simulated ischaemic and haemorrhagic strokes in a realistic head model were reconstructed for varying degrees of electrode position errors. The simultaneous recovery of conductivity spectra and electrode positions removed most artefacts caused by inaccurately modelled electrodes. Reconstructions were stable for electrode position errors of up to 1.5 mm standard deviation along both surface dimensions. We conclude that this method can be used for electrode model correction in multi-frequency EIT.
Collapse
|
47
|
Dowrick T, Blochet C, Holder D. In vivobioimpedance changes during haemorrhagic and ischaemic stroke in rats: towards 3D stroke imaging using electrical impedance tomography. Physiol Meas 2016; 37:765-84. [DOI: 10.1088/0967-3334/37/6/765] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
48
|
Singh H, Cooper R, Lee CW, Dempsey L, Brigadoi S, Edwards A, Airantzis D, Everdell N, Michell A, Holder D, Austin T, Hebden J. Neurovascular Interactions in the Neurologically Compromised Neonatal Brain. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 876:485-492. [PMID: 26782249 DOI: 10.1007/978-1-4939-3023-4_61] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Neurological brain injuries such as hypoxic ischaemic encephalopathy (HIE) and associated conditions such as seizures have been associated with poor developmental outcome in neonates. Our limited knowledge of the neurological and cerebrovascular processes underlying seizures limits their diagnosis and timely treatment. Diffuse optical tomography (DOT) provides haemodynamic information in the form of changes in concentration of de/oxygenated haemoglobin, which can improve our understanding of seizures and the relationship between neural and vascular processes. Using simultaneous EEG-DOT, we observed distinct haemodynamic changes which are temporally correlated with electrographic seizures. Here, we present DOT-EEG data from two neonates clinically diagnosed as HIE. Our results highlight the wealth of mutually-informative data that can be obtained using DOT-EEG techniques to understand neurovascular coupling in HIE neonates.
Collapse
|
49
|
Jehl M, Avery J, Malone E, Holder D, Betcke T. Correcting electrode modelling errors in EIT on realistic 3D head models. Physiol Meas 2015; 36:2423-42. [PMID: 26502162 DOI: 10.1088/0967-3334/36/12/2423] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Electrical impedance tomography (EIT) is a promising medical imaging technique which could aid differentiation of haemorrhagic from ischaemic stroke in an ambulance. One challenge in EIT is the ill-posed nature of the image reconstruction, i.e., that small measurement or modelling errors can result in large image artefacts. It is therefore important that reconstruction algorithms are improved with regard to stability to modelling errors. We identify that wrongly modelled electrode positions constitute one of the biggest sources of image artefacts in head EIT. Therefore, the use of the Fréchet derivative on the electrode boundaries in a realistic three-dimensional head model is investigated, in order to reconstruct electrode movements simultaneously to conductivity changes. We show a fast implementation and analyse the performance of electrode position reconstructions in time-difference and absolute imaging for simulated and experimental voltages. Reconstructing the electrode positions and conductivities simultaneously increased the image quality significantly in the presence of electrode movement.
Collapse
|
50
|
Jehl M, Dedner A, Betcke T, Aristovich K, Klöfkorn R, Holder D. A fast parallel solver for the forward problem in electrical impedance tomography. IEEE Trans Biomed Eng 2015; 62:126-37. [PMID: 25069109 DOI: 10.1109/tbme.2014.2342280] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Electrical impedance tomography (EIT) is a noninvasive imaging modality, where imperceptible currents are applied to the skin and the resulting surface voltages are measured. It has the potential to distinguish between ischaemic and haemorrhagic stroke with a portable and inexpensive device. The image reconstruction relies on an accurate forward model of the experimental setup. Because of the relatively small signal in stroke EIT, the finite-element modeling requires meshes of more than 10 million elements. To study the requirements in the forward modeling in EIT and also to reduce the time for experimental image acquisition, it is necessary to reduce the run time of the forward computation. We show the implementation of a parallel forward solver for EIT using the Dune-Fem C++ library and demonstrate its performance on many CPU's of a computer cluster. For a typical EIT application a direct solver was significantly slower and not an alternative to iterative solvers with multigrid preconditioning. With this new solver, we can compute the forward solutions and the Jacobian matrix of a typical EIT application with 30 electrodes on a 15-million element mesh in less than 15 min. This makes it a valuable tool for simulation studies and EIT applications with high precision requirements. It is freely available for download.
Collapse
|