26
|
Bartolomeu F, Costa MM, Alves N, Miranda G, Silva FS. Selective Laser Melting of Ti6Al4V sub-millimetric cellular structures: Prediction of dimensional deviations and mechanical performance. J Mech Behav Biomed Mater 2020; 113:104123. [PMID: 33032011 DOI: 10.1016/j.jmbbm.2020.104123] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Revised: 09/16/2020] [Accepted: 09/28/2020] [Indexed: 12/21/2022]
Abstract
Ti6Al4V sub-millimetric cellular structures arise as promising solutions concerning the progress of conventional orthopedic implants due to its ability to address a combination of mechanical, physical and topological properties. Such ability can improve the interaction between implant materials and surrounding bone leading to long-term successful orthopedic implants. Selective Laser Melting (SLM) capability to produce high quality Ti6Al4V porous implants is in great demand towards orthopedic biomaterials. In this study, Ti6Al4V cellular structures were designed, modeled, SLM produced and characterized targeting orthopedic implants. For that purpose, a set of tools is proposed to overcome SLM limited accuracy to produce porous biomaterials with desired dimensions and mechanical properties. Morphological analyses were performed to evaluate the dimensional deviations noticed between the model CAD and the SLM produced structures. Tensile tests were carried out to estimate the elastic modulus of the Ti6Al4V cellular structures. The present work proposes a design methodology showing the linear correlations found for the dimensions, the porosity and the elastic modulus when comparing the model CAD designs with Ti6Al4V structures by SLM.
Collapse
|
27
|
Dantas TA, Carneiro Neto JP, Alves JL, Vaz PCS, Silva FS. In silico evaluation of the stress fields on the cortical bone surrounding dental implants: Comparing root-analogue and screwed implants. J Mech Behav Biomed Mater 2020; 104:103667. [PMID: 32174425 DOI: 10.1016/j.jmbbm.2020.103667] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/29/2020] [Accepted: 02/01/2020] [Indexed: 02/06/2023]
Abstract
Tooth loss is a problem that affects both old and young people. It may be caused by several conditions, such as poor oral hygiene, lifestyle choices or even diseases like periodontal disease, tooth grinding or diabetes. Nowadays, replacing a missing tooth by an implant is a very common process. However, many limitations regarding the actual strategies can be enumerated. Conventional screwed implants tend to induce high levels of stress in the peri-implant bone area, leading to bone loss, bacterial bio-film formation, and subsequent implant failure. In this sense, root-analogue dental implants are becoming promising solutions for immediate implantation due to their minimally invasive nature, improved bone stress distribution and because they do not require bone drilling, sinus lift, bone augmentation nor other traumatic procedures. The aim of this study was to analyse and compare, by means of FEA, the stress fields of peri-implant bone around root-analogue and screwed conventional zirconia implants. For that purpose, one root-analogue implant, one root-analogue implant with flaps, two conventional implants (with different threads) and a replica of a natural tooth were modelled. COMSOL was used to perform the analysis and implants were subjected to two simultaneous loads: 100 N axially and 100 N oblique (45°). RESULTS: revealed that root-analogue implants, namely with flaps, should be considered as promising alternatives for dental implant solutions since they promote a better stress distribution in the cortical bone when compared with conventional implants.
Collapse
|
28
|
Leal A, Andrade R, Flores P, Silva FS, Fulkerson J, Neyret P, Arendt E, Espregueira-Mendes J. Unilateral anterior knee pain is associated with increased patellar lateral position after stressed lateral translation. Knee Surg Sports Traumatol Arthrosc 2020; 28:454-462. [PMID: 31375878 DOI: 10.1007/s00167-019-05652-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 07/26/2019] [Indexed: 12/28/2022]
Abstract
PURPOSE To objectively compare side-to-side patellar position and mobility in patients with idiopathic unilateral anterior knee pain (AKP) using a stress-testing device concomitantly with magnetic resonance imaging. It is hypothesized that the painful knees present greater patellar mobility than the contralateral non-painful knees. METHODS From a total sample of 359 patients, 23 patients with idiopathic unilateral AKP (30.9 years, 23.4 kg/m2, 43% males) were included within the present study. Both knees of all the patients were examined by conventional imaging, including the measurement of trochlear sulcus angle, Caton-Deschamps index, tibial tuberosity to trochlear groove distance, patellar tilt angle and patellar subluxation (both at rest and upon quadriceps contraction). Additionally, the same patients underwent stress testing (Porto Patella Testing Device); these measurements were taken with the patella at rest, after lateral patellar translation and after lateral patellar tilt. Clinical and functional outcomes were obtained using physical examination and the Kujala and Lysholm scores. RESULTS Painful knees showed statistically significant higher patellar lateral position after stressed lateral translation than non-painful knees (p = 0.028), 9.8 ± 3.6 mm and 7.1 ± 6.3 mm, respectively. The adjusted multivariate logistic model identified the patellar position after lateral displacement to be significantly associated with AKP (OR = 1.165) and the model (AUC = 0.807, p < 0.001) showed reasonable sensitivity (67%) and specificity (73%). CONCLUSION Patients with idiopathic unilateral AKP with morphologically equivalent knees showed statistically significant increased patellar lateral position after stressed lateral displacement in their painful knee. The greater lateral patellar mobility quantified by the PPTD testing brings more objectivity to the diagnosis. LEVEL OF EVIDENCE II.
Collapse
|
29
|
Faria D, Madeira S, Buciumeanu M, Silva FS, Carvalho O. Novel laser textured surface designs for improved zirconia implants performance. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 108:110390. [PMID: 31923937 DOI: 10.1016/j.msec.2019.110390] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 10/27/2019] [Accepted: 10/31/2019] [Indexed: 12/15/2022]
Abstract
The development of new surface designs to enhance the integration process between surgically placed implants and biological tissues remains a challenge for the scientific community. In this way and trying to overcome this issue, in this work, laser technology was explored to produce novel textures on the surface of green zirconia compacts produced by cold pressing technique. Two strategies regarding line design (8 and 16 lines design) and different laser parameters (laser power and number of laser passages) were explored to assess their influence on geometry and depth of created textures. The produced textures were evaluated with Scanning Electron Microscopy (SEM) and it was observed that well-defined textured surfaces with regular geometric features (cavities or pillars) were obtained by laser combining different strategies lines design and parameters. The potential of proposed textures was also evaluated regarding surface wettability, friction performance (static and dynamic coefficient of friction evolution) against bone, aging resistance and flexural strength. Results demonstrated that all the produced textures display a super hydrophilic or hydrophilic behavior. Regarding the friction behavior, it was experimentally observed a high initial static coefficient of friction (COF) for all produced textures. Concerning the aging resistance, all the textured surfaces revealed a low monoclinic content, less than 25% after 5 h of hydrothermal aging. The flexural strength results showed that the mechanical resistance of zirconia was not significantly compromised with the laser action. Based on the obtained results, it is possible to prove that the processing route used for manufacturing the new and different surface designs (cold pressing technique followed by laser texturing) showed to be particularly effective for the production of zirconia implants with customized surface designs according to the properties required in a specific application. These new surface designs besides to enhance the surface wettability and also to improve the fixation at the initial moment of the implantation, do not significantly compromise the resistance to aging and the mechanical performance of zirconia. Hence, a positive impact on the long-term performance of the zirconia implants may be expected with the proposed novel laser textured surface designs.
Collapse
|
30
|
Madeira S, Mesquita-Guimarães J, Ribeiro P, Fredel M, Souza JCM, Soares D, Silva FS, Henriques B. Y-TZP/porcelain graded dental restorations design for improved damping behavior - A study on damping capacity and dynamic Young's modulus. J Mech Behav Biomed Mater 2019; 96:219-226. [PMID: 31055212 DOI: 10.1016/j.jmbbm.2019.04.033] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 04/16/2019] [Accepted: 04/17/2019] [Indexed: 01/12/2023]
Abstract
The development of dental restorative materials that mimic tooth-like properties provided by graded structures, aesthetics and properties such as strength, damping capacity and the ability for a continuous remodeling according to the biomechanical solicitation is a great challenge. In this work, damping capacity and dynamic Young's modulus of Y-TZP/porcelain composites for all-ceramic dental restorations were studied. These mechanical properties were assessed by dynamic mechanical analyses (DMA) at frequencies of 1, 5 and 10 Hz, over a temperature ranging from 0 to 60 °C, simulating extreme conditions when a cold or hot drink is experienced. The results showed that porcelain and porcelain-matrix composites exhibited higher damping capacity while Y-TZP and Y-TZP-matrix composites presented higher dynamic Young's modulus. Furthermore, while damping capacity is strongly influenced by the temperature, no significant difference in dynamic Young's modulus was found. For both damping and modulus properties, no significant influence of frequency was found for the tested materials. Based on the obtained results and also on the known advantages of the graded Y-TZP/porcelain structures over traditional bi-layer solutions (e.g., improved bending strength, enhanced mechanical and thermal stress distribution), a novel design of all-ceramic restoration with damping capacity has been proposed at the end of this study. A positive impact on the long-term performance of these all-ceramic restorations may be expected.
Collapse
|
31
|
Roedel S, Mesquita-Guimarães J, Souza JCM, Silva FS, Fredel MC, Henriques B. Production and characterization of zirconia structures with a porous surface. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 101:264-273. [PMID: 31029319 DOI: 10.1016/j.msec.2019.03.087] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Revised: 02/07/2019] [Accepted: 03/24/2019] [Indexed: 12/21/2022]
Abstract
The aim of this study was to produce zirconia structures with a porous surface by the dip coating technique and assess the mechanical properties of the structures as well as the integrity of the porous layers. Surface porous layers with homogenous and graded porosity were produced over zirconia substrate discs using zirconia powders with different average sizes (d50 = 40 μm; d50 = 70 μm and d50 = 100 μm) and without pore forming fugitive phases. Specimens were inspected using Scanning Electron Microscopy. Bending strength of specimens was obtained from biaxial flexural tests (B3B). Porous layers were successfully produced on zirconia discs substrates and the bending strength of these specimens were ~35% lower than uncoated specimens. Delamination occurred especially in layers with higher thickness and made of bigger particles. Practical application examples were provided in this paper showing the versatility of these porous surfaces in the production of multifunctional surfaces for stronger interfaces.
Collapse
|
32
|
Costa MM, Bartolomeu F, Alves N, Silva FS, Miranda G. Tribological behavior of bioactive multi-material structures targeting orthopedic applications. J Mech Behav Biomed Mater 2019; 94:193-200. [PMID: 30903863 DOI: 10.1016/j.jmbbm.2019.02.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 01/18/2019] [Accepted: 02/28/2019] [Indexed: 11/29/2022]
Abstract
The following study proposes a multi-material solution in which Ti6Al4V cellular structures produced by Selective Laser Melting are impregnated with bioactive materials (hydroxyapatite or β-tricalcium phosphate) using press and sintering technique. To assess the tribological response of these structures, an alumina plate was used as a counterpart in a flat-on-flat reciprocating sliding test. Ti6Al4V cellular structures impregnated with bioactive materials displayed the highest wear resistance when compared with the unreinforced structures. Among the bioactive structures, Ti6Al4V cellular structures impregnated with βTCP were the ones with higher wear resistance, having the lowest weight loss. Hence, these structures are promising multifunctional solutions for load-bearing applications by gathering suitable mechanical properties (strength and stiffness); bioactive properties and in addition an improved wear performance.
Collapse
|
33
|
Peñarrieta-Juanito G, Sordi MB, Henriques B, Dotto MER, Teughels W, Silva FS, Magini RS, Souza JCM. Surface damage of dental implant systems and ions release after exposure to fluoride and hydrogen peroxide. J Periodontal Res 2018; 54:46-52. [PMID: 30368813 DOI: 10.1111/jre.12603] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 07/20/2018] [Accepted: 08/02/2018] [Indexed: 01/16/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate surface changes on dental implant systems and ions release after immersion in fluoride and hydrogen peroxide. METHODS Ten implant-abutment assemblies were embedded in acrylic resin and cross-sectioned along the implant vertical axis. Samples were wet ground and polished. Delimited areas of groups of samples were immersed in 1.23% sodium fluoride gel (F) or in 35% hydrogen peroxide (HP) for 16 min. Gels (n = 3) were collected from the implant surfaces and analyzed by inductively coupled plasma mass spectrometry (ICP-MS), to detect the concentration of metallic ions released from the implant systems. Selected areas of the abutment and implant (n = 15) were analyzed by atomic force microscopy (AFM) and scanning electron microscopy (SEM). RESULTS SEM images revealed surface topographic changes on implant-abutment joints after immersion in fluoride. Implants showed excessive oxidation within loss of material, while abutment surfaces revealed intergranular corrosion after immersion in fluoride. ICP-MS results revealed a high concentration of Ti, Al, V ions in fluoride after contact with the implant systems. Localized corrosion of implant systems could not be detected by SEM after immersion in hydrogen peroxide although the profilometry showed increase in roughness. ICP-MS showed the release of metallic ions in hydrogen peroxide medium after contact with dental implants. CONCLUSION Therapeutical substances such as fluorides and hydrogen peroxide can promote the degradation of titanium-based dental implant and abutments leading to the release of toxic ions.
Collapse
|
34
|
Dantas TA, Roedel S, Mesquita-Guimarães J, Pinto P, Souza JCM, Fredel MC, Silva FS, Henriques B. Sliding behavior of zirconia porous implant surfaces against bone. J Biomed Mater Res B Appl Biomater 2018; 107:1113-1121. [PMID: 30230711 DOI: 10.1002/jbm.b.34204] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 06/25/2018] [Accepted: 07/01/2018] [Indexed: 01/27/2023]
Abstract
Different zirconia porous layers were produced on zirconia dense zirconia substrates by slip casting using powder with different mean sizes: 40 μm (Z40), 70 μm (Z70), and 100 μm (Z100). The dynamic and static coefficients of friction against bovine femoral bone, mimicking the implantation process, were conducted using a ball-on-flat reciprocating sliding tribometer under 3 N of normal load. Additionally, the porous layers were assessed with regard to their low temperature degradation (aging). Results revealed that the porous layers were able to keep their integrity during the sliding testes against bone, with no zirconia particles being transferred to the bone. Results did not show significant differences (p > 0.05) in kinetic and static COF values for Z40, Z70, Z100, and GRAD specimens, ranging from 0.53 to 0.77 and 0.65 to 0.90, respectively. The aging tests revealed that all surfaces were prone to low temperature degradation (~49% of monoclinic content after 18 h). In conclusion, the cohesive integrity of the layers and relatively high COF observed reveled that zirconia porous layers may be considered for replacing the current implant surfaces, and are expected to improve their primary stability. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1113-1121, 2019.
Collapse
|
35
|
Macedo MGFP, Volpato CAM, Henriques BAPC, Vaz PCS, Silva FS, Silva CFCL. Color stability of a bis-acryl composite resin subjected to polishing, thermocycling, intercalated baths, and immersion in different beverages. J ESTHET RESTOR DENT 2018; 30:449-456. [PMID: 30194894 DOI: 10.1111/jerd.12404] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Revised: 04/22/2018] [Accepted: 05/26/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate the color of a bis-acryl resin after polishing, aging, and colorants. MATERIALS AND METHODS From the 140 disks obtained, 35 were not polished (NP), 35 were polished with 3-μm (3P), 35 with 3- and 1-μm (1P), and 35 with 3-, 1-, and 0.5-μm sized particles (05P). Five disks of each group were thermocycled for 20, 100, and 200 cycles. Sixty disks were thermocycled and kept in beverages (tea, wine, and coffee) after four cycles. Sixty disks were immersed in the beverages for 24 hours, a week, and a month. The coordinates L*a*b* were measured and the color differences were analyzed by ANOVA. The lightness, chroma, and hue differences were evaluated by repeated measures ANOVA. Comparisons were made with Tukey's test (α = 0.05). RESULTS Similar behaviors were observed between 3P and 05P groups (1.53 and 1.95ΔE00 ) (P < .05). The NP group submitted to 200 cycles showed the biggest color differences (3.02) (P = .003). The greatest color differences were observed in the NP group submitted to immersion in coffee (8.30) and wine (7.93) (P < .05). CONCLUSIONS The polished surfaces were the least stained. Coffee and wine provided the greatest color changes, both for baths and immersions. CLINICAL SIGNIFICANCE Polishing of provisional surfaces restorations made of bis-acrylic resin is essential to minimize staining caused by aging and use of colorants, regardless of the particle size present in the polishing paste. The contact with coffee and red wine should be avoided, especially for clinical times greater than 1 week.
Collapse
|
36
|
Pessanha-Andrade M, Sordi MB, Henriques B, Silva FS, Teughels W, Souza JCM. Custom-made root-analogue zirconia implants: A scoping review on mechanical and biological benefits. J Biomed Mater Res B Appl Biomater 2018; 106:2888-2900. [PMID: 30070423 DOI: 10.1002/jbm.b.34147] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Revised: 03/18/2018] [Accepted: 04/09/2018] [Indexed: 12/26/2022]
Abstract
The aim of this study was to conduct a literature review on the potential benefits of custom-made root-analogue zirconia implants. A PubMed and ScienceDirect bibliographical search was carried out from 1969 to 2017. The increased interest in zirconia-based dental structures linked to aesthetic and biological outcomes have been reported in literature. Recent technological advances have focused on novel strategies for modification of zirconia-based surfaces to accelerate osseointegration. However, only a few studies revealed mechanical and biological benefits of custom-made root-analogue zirconia implants and therefore further studies should investigate the influence of different design and surface modification on the performance of such implants. Custom-made root-analogue zirconia implants have become a viable alternative to overcome limitations concerning stress distribution, aesthetics, and peri-implantitis induced by biofilms. However, further in vitro and in vivo studies on surface-bone interactions and mechanical behavior of zirconia should be evaluated to reduce clinical issues regarding mechanical failures and late peri-implant bone loss. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2888-2900, 2018.
Collapse
|
37
|
Pio IDSL, Lavor AL, Damasceno CMD, Menezes PMN, Silva FS, Maia GLA. Traditional knowledge and uses of medicinal plants by the inhabitants of the islands of the São Francisco river, Brazil and preliminary analysis of Rhaphiodon echinus (Lamiaceae). BRAZ J BIOL 2018; 79:87-99. [PMID: 29694558 DOI: 10.1590/1519-6984.177447] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 08/10/2017] [Indexed: 11/22/2022] Open
Abstract
This study aimed to carry out an ethnobotanical survey of medicinal plants used by inhabitants of the Rodeadouro Island, Jatoba Island and Massangano Island, located in The Submedium São Francisco River Valley. Also phytochemicals and preliminary pharmacological tests were performed to species most cited by the community. Ethnobotanical data were collected through observation visits and semi-structured interviews with 12 key informants. We calculated the relative importance (RI), the percentage of agreement related to the main uses (cAMU) and use value (UV). The aerial parts of Rhaphiodon echinus (Ness & Mart.) Schauer were used to obtain the lyophilizate (LYO-Re), crude ethanol extract (CEE-Re) and their hexanic (HEX-Re), chloroform (CLO-Re) and ethyl acetate (EA-Re) fractions. The microdilution technique was used for determining Minimum inhibitory concentration (MIC) for selected microorganisms. Already the spasmolytic effect was evaluated in isolated uterus fragments of Wistar rats, pre contracted with KCl 60 mM. We found 34 species cited, belonging to 22 families. The most plants were grown by locals. There were 51 different diseases, but the main indication was infectious and parasitic diseases. The species R. echinus was the most reported and it was indicated for urinary tract infection and dysmenorrhea. The screening revealed a higher prevalence of flavonoids, tannins, lignans and saponins in LYO-Re and AE-Re. Already terpene compounds were more present in HEX-Re and CLO-Re. The RE-Re fraction stood out with strong effect against E. coli and S. aureus while CEE-Re has moderate effect against gram-negative bacteria. The evaluation of the spasmolytic activity showed that LYO-Re, CEE-Re and HEX-Re fractions have similar activity, with partial effect and concentration-dependent response. This work brought about knowledge and use of medicinal plants by the riparian of the São Francisco River. It also revealed the importance of other methodologies for scientific evidence for the popular use of R. echinus.
Collapse
|
38
|
Henriques B, Fabris D, Souza JCM, Silva FS, Carvalho Ó, Fredel MC, Mesquita-Guimarães J. Bond strength enhancement of zirconia-porcelain interfaces via Nd:YAG laser surface structuring. J Mech Behav Biomed Mater 2018. [PMID: 29524754 DOI: 10.1016/j.jmbbm.2018.02.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the effect of laser surface structuring on the bond strength of feldspar-based porcelain to zirconia, as compared to conventional sandblasting treatment. MATERIALS AND METHODS Thirty cylindrical zirconia substrates, previously sintered, were divided in three groups according to the type of surface conditioning: 1) sandblasting with 50 µm Al2O3; 2) laser structuring (Ø25 µm holes); and 3) laser structuring (Ø50 µm holes). Porcelain was injected onto the zirconia substrates. X-ray diffractometry (XRD) was used to evaluate the influence of the laser treatment on zirconia crystallographic phases. Shear bond strength test was performed. Micrographs using SEM were used to evaluate the zirconia surface after each surface treatment and to evaluate the fracture surface after the shear test. RESULTS The laser-structured groups presented the highest shear bond strength (65 ± 16 MPa and 65 ± 11 MPa, for the 25 µm and 50 µm holes, respectively). The sandblasting samples presented shear bond strength of 37 ± 16 MPa. XRD analysis showed that there was no phase transformation on the thermally affected surface due to laser action. Microcracks were created at some holes due to the high temperature gradient generated by laser. SIGNIFICANCE Laser structuring significantly increased (up to 75%) the shear bond strength of zirconia to veneering porcelain as compared to conventional sandblasting treatment. Therefore, laser structuring arises as a surface conditioning method for producing stronger and long lasting zirconia-porcelain interfaces.
Collapse
|
39
|
Fabris D, Souza JC, Silva FS, Fredel M, Gasik M, Henriques B. Influence of specimens’ geometry and materials on the thermal stresses in dental restorative materials during thermal cycling. J Dent 2018; 69:41-48. [DOI: 10.1016/j.jdent.2017.08.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Revised: 08/22/2017] [Accepted: 08/24/2017] [Indexed: 11/16/2022] Open
|
40
|
Costa-Neta BM, da Silva AA, Brito JM, Moraes JLP, Rebêlo JMM, Silva FS. Light-Emitting Diode (LED) Traps Improve the Light-Trapping of Anopheline Mosquitoes. JOURNAL OF MEDICAL ENTOMOLOGY 2017; 54:1699-1703. [PMID: 28968803 DOI: 10.1093/jme/tjx148] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Indexed: 06/07/2023]
Abstract
Numerous advantages over the standard incandescent lamp favor the use of light-emitting diodes (LEDs) as an alternative and inexpensive light source for sampling medically important insects in surveillance studies. Previously published studies examined the response of mosquitoes to different wavelengths, but data on anopheline mosquito LED attraction are limited. Center for Disease Control and Prevention-type light traps were modified by replacing the standard incandescent lamp with 5-mm LEDs, one emitting at 520 nm (green) and the other at 470 nm (blue). To test the influence of moon luminosity on LED catches, the experiments were conducted during the four lunar phases during each month of the study period. A total of 1,845 specimens representing eight anopheline species were collected. Anopheles (Nyssorhynchus) evansae (35.2%) was the most frequently collected, followed by An. (Nys.) triannulatus (21.9%), An. (Nys.) goeldii (12.9%), and An. (Nys.) argyritarsis (11.5%). The green LED was the most attractive light source, accounting for 43.3% of the individuals collected, followed by the blue (31.8%) and control (24.9%) lights. The LED traps were significantly more attractive than the control, independent of the lunar phase. Light trapping of anopheline mosquitoes was more efficient when the standard incandescent lamp was replaced with LEDs, regardless of the moon phase. The efficiency of LEDs improves light trapping results, and it is suggested that the use of LEDs as an attractant for anopheline mosquitoes should be taken into consideration when sampling anopheline mosquitoes.
Collapse
|
41
|
Dantas TA, Costa MM, Miranda G, Silva FS, Abreu CS, Gomes JR. Effect of HAp and β-TCP incorporation on the tribological response of Ti6Al4V biocomposites for implant parts. J Biomed Mater Res B Appl Biomater 2017; 106:1010-1016. [PMID: 28480642 DOI: 10.1002/jbm.b.33908] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Revised: 04/07/2017] [Accepted: 04/14/2017] [Indexed: 01/17/2023]
Abstract
Titanium and its alloys have been widely used in many engineering areas due to their properties. Despite having a high implant-tissue osseointegration time, Ti6Al4V has been extensively used in prosthesis and articular implants. To promote a faster bone ingrowth and consequently reduce the implant fixation time, the addition of a bioactive phase to form a biocomposite seems to be an excellent solution. Because of their bioactivity and similarity in composition with the human bone, HAp and β-TCP are two of the most widely used calcium phosphates in biomedical applications. To guarantee a strong adhesion of the previous bioactive materials in the implants surface, samples of Ti6Al4V, Ti6Al4V+HAp (10 vol %) and Ti6Al4V+β-TCP (10 vol %) TCP were processed by the hot pressing technique. Tribological tests against Al2 O3, lubricated in PBS at 37°C were carried out on a ball-on-flat reciprocating sliding geometry. Loads in the range of 3 N to 30 N were applied and their effect on the friction behavior and wear resistance of the tested materials was evaluated. Values of the coefficient of friction as well as the wear rate tend to increase with the addition of a bioactive phase to the Ti alloy. Micrographs of the worn surfaces showed that abrasion and plastic deformation are the prevailing wear mechanisms in the studied tribosystems. For biocomposites, particularly in the case of Ti6Al4V+HAp, pull-out of bioactive particle clusters has a determinant role on the tribological response, increasing both the friction coefficient and the specific wear rate. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1010-1016, 2018.
Collapse
|
42
|
Prado AM, Pereira J, Silva FS, Henriques B, Nascimento RM, Benfatti CAM, López-López J, Souza JCM. Wear of Morse taper and external hexagon implant joints after abutment removal. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2017; 28:65. [PMID: 28321800 DOI: 10.1007/s10856-017-5879-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Accepted: 03/02/2017] [Indexed: 06/06/2023]
Abstract
The aim of this in vitro study was to evaluate the removal torque values on abutments and the morphological wear aspects of two different dental implant joints after immersion in a medium containing biofilm from human saliva. Twenty implant-abutment assemblies were divided into four groups in this study: (A) Morse taper free of medium containing biofilm, and (B) after contact with a medium containing biofilm from human saliva; (C) External Hexagon free of medium containing biofilm, and (D) after contact with medium containing biofilm from human saliva. The abutments were firstly torqued to the implants according to the manufacturer´s recommendations, using a handheld torque meter. Groups B and D were immersed into 24 well-plates containing 2 ml BHI medium with microorganisms for 72 h at 37 °C under microaerophilic conditions. After detorque evaluation, the abutments were removed and the implants were analyzed by scanning electron microscopy (SEM) and profilometry. On the detorque evaluation, the torque values decreased for the external hexagon implants and increased for the Morse taper implants. However, the values were lower when both implant-abutment assemblies were in contact with a medium containing biofilm from human saliva. The wear areas of contacting surfaces of the implants were identified by SEM. The highest average roughness values were recorded on the surfaces free of biofilm. The medium containing biofilm from human saliva affected the maintenance of the torque values on Morse taper and external hexagon abutments. Additionally, the removal of abutment altered the inner implant surfaces resulting in an increase of wear of the titanium-based connection.
Collapse
|
43
|
Dantas TA, Abreu CS, Costa MM, Miranda G, Silva FS, Dourado N, Gomes JR. Bioactive materials driven primary stability on titanium biocomposites. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 77:1104-1110. [PMID: 28531984 DOI: 10.1016/j.msec.2017.04.014] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Revised: 01/20/2017] [Indexed: 01/22/2023]
Abstract
The Ti6Al4V alloy constitutes an alternative choice to the most common metal-polymer solutions for total hip arthroplasty (THA) due to good biocompatibility, optimal mechanical properties and high load bearing capacity. However, as Ti6Al4V is not bioactive in its conventional form, hydroxyapatite (HAp) and tricalcium phosphate (TCP) have been widely used as coatings of metal prostheses due to their osteogenic properties and ability to form strong bonds with bone tissue. A promising approach consists in creating a bioactive surface metal matrix composite Ti6Al4V+β-TCP or Ti6Al4V+HAp, obtained by hot pressing (HP) of powders. In this work, the tribological performance of Ti6Al4V+β-TCP and Ti6Al4V+HAp composites is studied to evaluate the frictional response and surface damage representative of prosthesis implantation, key factors in bone fixation. Biocomposites with 10vol% β-TCP and 10vol% Hap, as well as base titanium alloy, were prepared by HP with two surface finishing conditions - polished (Ra=0.3-0.5μm) and sandblasted (Ra=2.1-2.5μm) - for tribological testing against bovine cortical bone tissue. The static friction increases with surface roughness (from 0.20 to 0.60), whereas the kinetic regime follows an inverse trend for the biocomposites. In contrast with current knowledge, this study shows that an implant design solution based on Ti6Al4V+β-TCP or Ti6Al4V+HAp biocomposites with polished surfaces results in an improved primary stability of implants, when compared to traditional rough surfaces. Moreover, it is also expected that the secondary stability will improve due to the adhesion between bone and HAp/β-TCP, increasing the overall stability of the implant.
Collapse
|
44
|
Fabris D, Souza JC, Silva FS, Fredel M, Mesquita-Guimarães J, Zhang Y, Henriques B. THERMAL RESIDUAL STRESSES IN BILAYERED, TRILAYERED AND GRADED DENTAL CERAMICS. CERAMICS INTERNATIONAL 2017; 43:3670-3678. [PMID: 28163345 PMCID: PMC5289668 DOI: 10.1016/j.ceramint.2016.11.209] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Layered ceramic systems are usually hit by residual thermal stresses created during cooling from high processing temperature. The purpose of this study was to determine the thermal residual stresses at different ceramic multi-layered systems and evaluate their influence on the bending stress distribution. Finite elements method was used to evaluate the residual stresses in zirconia-porcelain and alumina-porcelain multi-layered discs and to simulate the 'piston-on-ring' test. Temperature-dependent material properties were used. Three different multi-layered designs were simulated: a conventional bilayered design; a trilayered design, with an intermediate composite layer with constant composition; and a graded design, with an intermediate layer with gradation of properties. Parameters such as the interlayer thickness and composition profiles were varied in the study. Alumina-porcelain discs present smaller residual stress than the zirconia-porcelain discs, regardless of the type of design. The homogeneous interlayer can yield a reduction of ~40% in thermal stress relative to bilayered systems. Thinner interlayers favoured the formation of lower thermal stresses. The graded discs showed the lowest thermal stresses for a gradation profile given by power law function with p=2. The bending stresses were significantly affected by the thermal stresses in the discs. The risk of failure for all-ceramic dental restorative systems can be significantly reduced by using trilayered systems (homogenous or graded interlayer) with the proper design.
Collapse
|
45
|
Fabris D, Souza JC, Silva FS, Fredel M, Mesquita-Guimarães J, Zhang Y, Henriques B. The bending stress distribution in bilayered and graded zirconia-based dental ceramics. CERAMICS INTERNATIONAL 2016; 42:11025-11031. [PMID: 28104926 PMCID: PMC5241077 DOI: 10.1016/j.ceramint.2016.03.245] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The purpose of this study was to evaluate the biaxial flexural stresses in classic bilayered and in graded zirconia-feldspathic porcelain composites. A finite element method and an analytical model were used to simulate the piston-on-ring test and to predict the biaxial stress distributions across the thickness of the bilayer and graded zirconia-feldspathic porcelain discs. An axisymmetric model and a flexure formula of Hsueh et al. were used in the FEM and analytical analysis, respectively. Four porcelain thicknesses were tested in the bilayered discs. In graded discs, continuous and stepwise transitions from the bottom zirconia layer to the top porcelain layer were studied. The resulting stresses across the thickness, measured along the central axis of the disc, for the bilayered and graded discs were compared. In bilayered discs, the maximum tensile stress decreased while the stress mismatch (at the interface) increased with the porcelain layer thickness. The optimized balance between both variables is achieved for a porcelain thickness ratio in the range of 0.30-0.35. In graded discs, the highest tensile stresses were registered for porcelain rich interlayers (p=0.25) whereas the zirconia rich ones (p=8) yield the lowest tensile stresses. In addition, the maximum stresses in a graded structure can be tailored by altering compositional gradients. A decrease in maximum stresses with increasing values of p (a scaling exponent in the power law function) was observed. Our findings showed a good agreement between the analytical and simulated models, particularly in the tensile region of the disc. Graded zirconia-feldspathic porcelain composites exhibited a more favourable stress distribution relative to conventional bilayered systems. This fact can significantly impact the clinical performance of zirconia-feldspathic porcelain prostheses, namely reducing the fracture incidence of zirconia and the chipping and delamination of porcelain.
Collapse
|
46
|
Silva FS, da Silva AA, Rebêlo JMM. An Evaluation of Light-Emitting Diode (LED) Traps at Capturing Phlebotomine Sand Flies (Diptera: Psychodidae) in a Livestock Area in Brazil. JOURNAL OF MEDICAL ENTOMOLOGY 2016; 53:634-638. [PMID: 27026156 DOI: 10.1093/jme/tjw016] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Accepted: 02/13/2016] [Indexed: 06/05/2023]
Abstract
A study to evaluate the use of light-emitting diodes (LEDs) as an attractant for phlebotomine sand flies at two animal pens in a livestock area in Brazil was performed. Light-suction traps were operated overnight with the following light sources: green, blue, and incandescent (control) lights. In total, 22 individual collections were made at each site and 44 with each trap type. In total, 2,542 specimens belonging to 14 phlebotomine species were collected. The most abundant species in the light traps were Nyssomyia whitmani, Evandromyia evandroi, Micropygomyia goiana, Lutzomyia longipalpis, and Bichromomyia flaviscutellata Taking the two sites together, the green-LED light was the most attractive, followed by the blue and incandescent lights, and the difference between the green-LED and the control was statistically significant. Most species were green-biased at both sites, but some species-specific differences were observed. However, even with these differences, the standard incandescent light was outcompeted by LEDs. The green-LED-biased response observed in the present study, together with numerous advantages in favor of LEDs, suggests that the green-LED light source can be used as an effective substitute for the currently used incandescent bulb in monitoring traps for phlebotomine sand flies in Brazil.
Collapse
|
47
|
Souza JCM, Silva JB, Aladim A, Carvalho O, Nascimento RM, Silva FS, Martinelli AE, Henriques B. Effect of Zirconia and Alumina Fillers on the Microstructure and Mechanical Strength of Dental Glass Ionomer Cements. Open Dent J 2016; 10:58-68. [PMID: 27053969 PMCID: PMC4797684 DOI: 10.2174/1874210601610010058] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 11/05/2015] [Accepted: 11/06/2015] [Indexed: 11/22/2022] Open
Abstract
Background: Glass-ionomer cements perform a protective effect on the dentin-pulp complex considering the F ions release and chemical bonding to the dental structures. On the other hand, those materials have poor physic-mechanical properties in comparison with the restorative resin composite. The main aim of this work was to evaluate the influence of zirconia and/or alumina fillers on the microstructure and strength of a resin modified glass-ionomer cement after thermal cycling. Methods: An in vitro experimental study was carried out on 9
groups (n = 10) of cylindrical samples (6 x 4 mm) made from resin
modified glass-ionomer (Vitremer, 3M, USA) with different contents of alumina
and/or zirconia fillers. A nano-hybrid resin composite was tested as a control
group. Samples were mechanically characterized by axial compressive tests and
electron scanning microscopy (SEM) coupled to energy dispersive X-ray
spectrophotometry (EDS), before and after thermal cycling. Thermal cycling
procedures were performed at 3000, 6000 and 10000 cycles in Fusayama´s
artificial saliva at 5 and 60 oC. Results: An improvement of compressive strength was noticed on glass-ionomer reinforced with alumina fillers in comparison with the commercial glass ionomer. SEM images revealed the morphology and distribution of alumina or zirconia in the microstructure of glass-ionomers. Also, defects such as cracks and pores were detected on the glass-ionomer cements. The materials tested were not affected by thermal cycling in artificial saliva. Conclusion: Addition of inorganic particles at nano-scale such as alumina can increase the mechanical properties of glass-ionomer cements. However, the presence of cracks and pores present in glass-ionomer can negatively affect the mechanical properties of the material because they are areas of stress concentration.
Collapse
|
48
|
Martins DC, Albuquerque PMC, Silva FS, Rebêlo JMM. First record of Aglae caerulea (Hymenoptera, Apidae, Euglossini) in Brazilian Cerrado east of the Amazon Region, Maranhão State, Brazil. BRAZ J BIOL 2016; 76:554-6. [PMID: 26959953 DOI: 10.1590/1519-6984.06415] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Accepted: 09/03/2015] [Indexed: 11/21/2022] Open
|
49
|
Sampaio M, Buciumeanu M, Henriques B, Silva FS, Souza JC, Gomes JR. Tribocorrosion behavior of veneering biomedical PEEK to Ti6Al4V structures. J Mech Behav Biomed Mater 2016; 54:123-30. [DOI: 10.1016/j.jmbbm.2015.09.010] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2015] [Revised: 09/08/2015] [Accepted: 09/10/2015] [Indexed: 11/26/2022]
|
50
|
Souza JCM, Tajiri HA, Morsch CS, Buciumeanu M, Mathew MT, Silva FS, Henriques B. Tribocorrosion Behavior of Ti6Al4V Coated with a Bio-absorbable Polymer for Biomedical Applications. ACTA ACUST UNITED AC 2015. [DOI: 10.1007/s40735-015-0029-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|