26
|
Winship B, Wollin D, Carlos E, Li J, Peters C, Simmons WN, Preminger GM, Lipkin M. Dusting Efficiency of the Moses Holmium Laser: An AutomatedIn VitroAssessment. J Endourol 2018; 32:1131-1135. [DOI: 10.1089/end.2018.0660] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
27
|
Carlos EC, Peters CE, Wollin DA, Winship BB, Davis LG, Li J, Scales CD, Eaton SH, Preminger GM, Lipkin ME. Psychiatric Diagnoses and Other Factors Associated with Emergency Department Return within 30 Days of Ureteroscopy. J Urol 2018; 201:556-562. [PMID: 30316894 DOI: 10.1016/j.juro.2018.09.062] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE Emergency department visits after ureteroscopy are costly and inconvenient. To better understand those at risk we aimed to identify patient demographic, medical and surgical factors associated with 30-day emergency department presentation following ureteroscopy for urolithiasis with particular attention to those with a history of a psychiatric diagnosis. MATERIALS AND METHODS We retrospectively reviewed 1,576 cases (1,395 adults) who underwent stone related ureteroscopy during 3 years at a total of 2 hospitals. We collected patient demographics, medical history and operative details. The primary outcome was return to the emergency department within 30 days of ureteroscopy. Logistic regression was performed to examine factors associated with emergency department presentation. RESULTS Of the patients 613 (43.9%) had a history of psychiatric diagnosis. Of those with ureteroscopy encounters 12.6% returned to the emergency department within 30 days of ureteroscopy, including 58.8% with a history of psychiatric diagnosis. On multivariable analysis variables associated with emergency department return included a history of psychiatric diagnosis (OR 1.57, p = 0.012), uninsured status (OR 2.46, p = 0.001) and a stone only in the kidney (OR 1.76, p = 0.022). Patients who returned to the emergency department had had more emergency department visits in the year prior to surgery (OR 1.40, p <0.001). On univariable analysis older patients and those with longer operative time were more frequently admitted from the emergency department (OR 1.03, p = 0.002 and OR 1.96, p = 0.03. respectively) while uninsured patients were admitted less frequently (OR 0.19, p = 0.013). No difference was noted in admissions between those with a psychiatric diagnosis and all others (60.7% vs 55.8%, p = 0.48). CONCLUSIONS We identified factors associated with emergency department return after ureteroscopy, including a history of psychiatric diagnosis, uninsured status and emergency department visits in the year before surgery. These patients may benefit from targeted interventions to help avoid unnecessary emergency department visits.
Collapse
|
28
|
Wollin DA, Kaplan AG, Preminger GM, Ferraro PM, Nouvenne A, Tasca A, Croppi E, Gambaro G, Heilberg IP. Defining metabolic activity of nephrolithiasis - Appropriate evaluation and follow-up of stone formers. Asian J Urol 2018; 5:235-242. [PMID: 30364613 PMCID: PMC6197397 DOI: 10.1016/j.ajur.2018.06.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 02/10/2018] [Accepted: 04/11/2018] [Indexed: 11/24/2022] Open
Abstract
Considering the variation in metabolic evaluation and medical management of kidney stone disease, this consensus review was created to discuss the metabolic activity of nephrolithiasis, define the difference between single and recurrent stone formers, and develop a schema for metabolic and radiologic follow-up. A systematic review of the literature was performed to identify studies of metabolic evaluation and follow-up of patients with nephrolithiasis. Both single and recurrent stone formers share many similarities in metabolic profiles. The study group determined that based on an assessment of risk for stone recurrence and metabolic activity, single and recurrent stone formers should be evaluated comprehensively, including two 24 h urine studies on a random diet. Targeted medication and dietary recommendations are effective for many patients in reducing the risk of stone recurrence. Follow-up of those with stone disease should be obtained depending on the level of metabolic activity of the patient, the risk of chronic kidney disease and the risk of osteoporosis/osteopenia. A standard scheme includes a baseline metabolic profile, a repeat study 3-6 months after initiation of treatment, and then yearly when stable, with abdominal imaging obtained every 1-2 years.
Collapse
|
29
|
Aksenov LI, Wietsma AC, Lipkin ME, Routh JC, Preminger GM, Scales CD. Analgesic Prescribing Patterns for Acute Symptomatic Kidney Stones in Emergency Departments. J Am Coll Surg 2018. [DOI: 10.1016/j.jamcollsurg.2018.08.425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
30
|
Cone EB, Hammill BG, Routh JC, Lipkin ME, Preminger GM, Schmader KE, Scales CD. Disproportionate Use of Inpatient Care by Older Adults With Kidney Stones. Urology 2018; 120:103-108. [PMID: 29940233 PMCID: PMC6689223 DOI: 10.1016/j.urology.2018.06.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 06/04/2018] [Accepted: 06/05/2018] [Indexed: 01/28/2023]
Abstract
OBJECTIVE To describe variation in utilization and costs of inpatient care for patients with kidney stones, examining associations with older age. MATERIALS AND METHODS Using the Nationwide Inpatient Sample we examined inpatient discharges with stone diagnoses from 2007 to 2011. We examined length of stay, hospitalization cost, and postdischarge care utilization using multivariable regression to identify associations between patient/hospital characteristics and resource. RESULTS An estimated 1.7 million hospital discharges for stone disease occurred during the study period. Median length of stay was 2.1 days with a median cost of $6300. Hospital use was substantially higher among persons ≥65 years old (older adults) as compared to those aged 18-64 (younger adults): median length of stay was 3.1 days, with 25% staying more than 5.9 days. Older adults were significantly more likely to utilize home health (odds ratio [OR] 3.6) or skilled nursing (OR 5.0) after discharge. Older adults accounted for 1 in 3 hospital discharges, 40% of costs, and half of postdischarge care utilization. They were more likely to be septic during hospitalization (OR 1.8) which doubled costs per episode, but less likely to receive surgery (OR 0.93). CONCLUSION While historically at lower risk for kidney stones compared to younger adults, older adults utilizing inpatient care account for a disproportionate share of the economic burden of disease. Utilization is higher for older adults across multiple dimensions, including hospital costs, length of stay, and postdischarge care. These findings suggest that efforts to understand and mitigate the impact of kidney stones on this vulnerable population are required.
Collapse
|
31
|
Carlos EC, Youssef RF, Kaplan AG, Wollin DA, Winship BB, Eisner BH, Sur RL, Preminger GM, Lipkin ME. Antibiotic Utilization Before Endourological Surgery for Urolithiasis: Endourological Society Survey Results. J Endourol 2018; 32:978-985. [DOI: 10.1089/end.2018.0494] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
32
|
Carlos EC, Li J, Young BJ, Radvak D, Wollin DA, Winship BB, Simmons WN, Preminger GM, Lipkin ME. Let's Get to the Point: Comparing Insertion Characteristics and Scope Damage of Flat-Tip and Ball-Tip Holmium Laser Fibers. J Endourol 2018; 33:22-26. [PMID: 29943662 DOI: 10.1089/end.2018.0229] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
INTRODUCTION A ball-tip holmium laser fiber (TracTip; Boston Scientific) has been developed to theoretically reduce damaging friction forces generated within a ureteroscope working channel. We compared the insertional forces and damage with a ureteroscope inner lining when inserting standard flat-tip and ball-tip laser fibers. MATERIALS AND METHODS A standard ureteroscope channel liner was placed in a 3D-printed plastic mold. Molds were created at four angles of deflection (30°, 45°, 90°, and 180°) with a 1 cm radius of curvature. New 200 μm ball-tip (TracTip; Boston Scientific) and 200 μm flat-tip (Flexiva; Boston Scientific) laser fibers were advanced through the liner using a stage controller. A strain gauge was used to measure force required for insertion. Each fiber was passed 600 times at each angle of deflection. The ureteroscope liner was changed every 150 passes. Leak testing was performed every 50 passes or when the insertional force increased significantly to assess damage to the liner. RESULTS At all deflection angles, the average insertional force was significantly lower with the ball-tip laser fibers compared with flat-tip laser fibers (p < 0.001). All trials with the ball-tip lasers were completed at each angle without any leaks. Two of four trials using flat-tip fibers at 45° deflection caused liner leaks (at 91 and 114 passes). At 90° deflection, all flat-tip trials caused liner leaks on first pass. The 180° trials could not physically be completed with the flat-tip laser fiber. Within the flat- and ball-tip groups, an increasing amount of force was needed to pass the fiber as the degree of deflection increased (p < 0.001). CONCLUSIONS The ball-tip holmium laser fiber can be safely passed through a deflected ureteroscope without causing liner perforation. The standard flat-tip fiber requires greater insertion force at all angles and can cause the ureteroscope liner to leak if it is deflected 45° or more.
Collapse
|
33
|
Wollin DA, Gupta RT, Young B, Cone E, Kaplan A, Marin D, Patel BN, Mazurowski MA, Scales CD, Ferrandino MN, Preminger GM, Lipkin ME. Abdominal Radiography With Digital Tomosynthesis: An Alternative to Computed Tomography for Identification of Urinary Calculi? Urology 2018; 120:56-61. [PMID: 30006268 DOI: 10.1016/j.urology.2018.06.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 06/28/2018] [Accepted: 06/29/2018] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To compare the accuracy of plain abdominal radiography (kidneys, ureter, and bladder [KUB]) with digital tomosynthesis (DT) to noncontrast computed tomography (NCCT), the gold standard imaging modality for urinary stones. Due to radiation and cost concerns, KUB is often used for diagnosis and follow-up of nephrolithiasis. DT, a novel technique that produces high-quality radiographs with less radiation and/or cost than low-dose NCCT, has not been assessed in this situation. MATERIALS AND METHODS Seven fresh tissue cadavers were implanted with stones of known size and/or composition and imaged with KUB, DT, and NCCT. Four blinded readers (2 urologists, 2 radiologists) evaluated KUBs for presence and/or location of calculi. They then re-evaluated with addition of tomograms to assess additional value. After a memory extinction period, readers evaluated NCCT images. Accuracy of detection was determined using nearest-neighbor match with generalized linear mixed modeling. RESULTS Total of 59 stones were identified on reference read. Overall, NCCT and DT were both superior to KUB alone (P < .001) while the difference between DT and NCCT was not significant (P = .06). When evaluating uric acid stones, NCCT and DT outperformed KUB (P < .01 and P < .05, respectively) while DT and NCCT were similar (P = .16). Intrarenal stones were better evaluated on DT and NCCT (P < .001 compared to KUB), while DT and NCCT were similar (P = 1.00). Accuracy was lower than anticipated across modalities due to use of the cadaver model. CONCLUSION Our study demonstrates DT is superior to KUB for identification of intrarenal calculi and could replace routine use of KUB or NCCT for detecting renal stones, even those composed of uric acid.
Collapse
|
34
|
Wollin DA, Tom WR, Jiang R, Simmons WN, Preminger GM, Lipkin ME. An in vitro evaluation of laser settings and location in the efficiency of the popcorn effect. Urolithiasis 2018; 47:377-382. [PMID: 29947996 DOI: 10.1007/s00240-018-1066-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Accepted: 06/08/2018] [Indexed: 11/30/2022]
Abstract
To examine different locations and laser settings' effects on the efficiency of the "popcorn" method of laser lithotripsy, which consists of placing the laser in a group of small stones and firing continuously to break them into smaller particles. Pre-fragmented BegoStones were created between 2 and 4 mm to mimic typical popcorning conditions. A 0.5 g collection of fragments was placed into 3D-printed models (a spherical calyx and ellipsoid pelvis model) and a 200-µm laser fiber was positioned above the stones. The laser was fired for 2 min with irrigation, with 5 trials at each setting: 0.2 J/50 Hz, 0.5 J/20 Hz, 0.5 J/40 Hz, 1 J/20 Hz, 0.2 J/80 Hz, 0.5 J/80 Hz. After drying, fragmentation efficiency was determined by calculating the mass of stones reduced to sub-2 mm particles. Statistical analysis was performed with ANOVA and Student's t test. The trials within the calyx model were significantly more efficient compared to the pelvis (0.19 vs 0.15 g, p = 0.01). When comparing laser settings, there was a difference between groups by one-way ANOVA [F(5,54) = 8.503, p = 5.47 × 10-6]. Post hoc tests showed a power setting of 0.5 J/80 Hz was significantly more efficient than low-power settings 0.2 J/50 Hz and 0.5 J/20 Hz (p < 0.05). Additionally, 0.2 J/50 Hz was significantly less efficient than 0.5 J/40 Hz, 1 J/20 Hz, and 0.2 J/80 Hz. Popcorning is most efficient in smaller spaces; we recommend displacement of stones into a calyx before popcorning. No difference was seen between high-power settings, although 0.5 J/40 Hz and 0.5 J/80 Hz performed best, suggesting that moderate energy popcorning methods with at least 0.5 J per pulse are most efficient.
Collapse
|
35
|
Carlos EC, Wollin DA, Winship BB, Jiang R, Radvak D, Chew BH, Gustafson MR, Simmons WN, Zhong P, Preminger GM, Lipkin ME. In Vitro Comparison of a Novel Single Probe Dual-Energy Lithotripter to Current Devices. J Endourol 2018; 32:534-540. [PMID: 29649900 DOI: 10.1089/end.2018.0143] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE The LithoClast Trilogy is a novel single probe, dual-energy lithotripter with ultrasonic (US) vibration and electromagnetic impact forces. ShockPulse and LithoClast Select are existing lithotripters that also use a combination of US and mechanical impact energies. We compared the efficacy and tip motion of these devices in an in vitro setting. MATERIALS AND METHODS Begostones, in the ratio 15:3, were used in all trials. Test groups were Trilogy, ShockPulse, Select ultrasound (US) only, and Select ultrasound with pneumatic (USP). For clearance testing, a single investigator facile with each lithotripter fragmented 10 stones per device. For drill testing, a hands-free apparatus with a submerged balance was used to apply 1 or 2 lbs of pressure on a stone in contact with the device tip. High-speed photography was used to assess Trilogy and ShockPulse's probe tip motion. RESULTS Select-USP was slowest and Trilogy fastest on clearance testing (p < 0.01). On 1 lbs drill testing, Select-US was slowest (p = 0.001). At 2 lbs, ShockPulse was faster than Select US (p = 0.027), but did not significantly outpace Trilogy nor Select-USP. At either weight, there was no significant difference between Trilogy and ShockPulse. During its US function, Trilogy's maximum downward tip displacement was 0.041 mm relative to 0.0025 mm with ShockPulse. Trilogy had 0.25 mm of maximum downward displacement during its impactor function while ShockPulse had 0.01 mm. CONCLUSIONS Single probe dual-energy devices, such as Trilogy and ShockPulse, represent the next generation of lithotripters. Trilogy more efficiently cleared stone than currently available devices, which could be explained by its larger probe diameter and greater downward tip displacement during both US and impactor functions.
Collapse
|
36
|
Taffel MT, Nikolaidis P, Beland MD, Blaufox MD, Dogra VS, Goldfarb S, Gore JL, Harvin HJ, Heilbrun ME, Heller MT, Khatri G, Preminger GM, Purysko AS, Smith AD, Wang ZJ, Weinfeld RM, Wong-You-Cheong JJ, Remer EM, Lockhart ME. ACR Appropriateness Criteria ® Renal Transplant Dysfunction. J Am Coll Radiol 2018; 14:S272-S281. [PMID: 28473084 DOI: 10.1016/j.jacr.2017.02.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 02/20/2017] [Accepted: 02/21/2017] [Indexed: 02/06/2023]
Abstract
Renal transplantation is the treatment of choice in patients with end-stage renal disease because the 5-year survival rates range from 72% to 99%. Although graft survival has improved secondary to the introduction of newer immunosuppression drugs and the advancements in surgical technique, various complications still occur. Ultrasound is the first-line imaging modality for the evaluation of renal transplants in the immediate postoperative period and for long-term follow-up. In addition to depicting many of the potential complications of renal transplantation, ultrasound can also guide therapeutic interventions. Nuclear medicine studies, CT, and MRI are often helpful as complementary examinations for specific indications. Angiography remains the reference standard for vascular complications and is utilized to guide nonsurgical intervention. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
|
37
|
Winship BB, Preminger GM. Editorial Comment on: Outpatient Percutaneous Nephrolithotomy: The UC San Diego Health Experience by Bechis et al. J Endourol 2018; 32:402. [PMID: 29571267 DOI: 10.1089/end.2018.0195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
38
|
Wollin DA, Carlos EC, Tom WR, Simmons WN, Preminger GM, Lipkin ME. Effect of Laser Settings and Irrigation Rates on Ureteral Temperature During Holmium Laser Lithotripsy, anIn VitroModel. J Endourol 2018; 32:59-63. [DOI: 10.1089/end.2017.0658] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
39
|
Wollin DA, Preminger GM. Percutaneous nephrolithotomy: complications and how to deal with them. Urolithiasis 2017; 46:87-97. [PMID: 29149365 DOI: 10.1007/s00240-017-1022-x] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Accepted: 11/11/2017] [Indexed: 11/29/2022]
Abstract
Percutaneous nephrolithotomy is a common surgical treatment for large and complex stones within the intrarenal collecting system. A wide variety of complications can result from this procedure, including bleeding, injury to surrounding structures, infection, positioning-related injuries, thromboembolic disease, and even death. Knowledge of the different types of complications can be useful in order to prevent, diagnose, and treat these problems if they occur. This review describes the diversity of complications with the goal of improving their avoidance and treatment.
Collapse
|
40
|
Cone EB, Jibara G, Wollin D, Preminger GM. Subcapsular Splenic Urinoma and Splenorenal Fistula: A New Complication of Percutaneous Nephrolithotomy. J Endourol Case Rep 2017; 3:134-137. [PMID: 29098195 PMCID: PMC5655835 DOI: 10.1089/cren.2017.0085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Background: Splenic urinoma has not been previously reported as a complication of percutaneous nephrolithotomy (PNL). Case Presentation: A 46-year-old Caucasian male underwent PNL for two large left renal stones. Surgery was performed in prone split-leg position, with access obtained through combined fluoroscopic guidance and direct ureteroscopic observation of the targeted calix. The tract was dilated to 30F using a pressure balloon, and complete clearance of stones was obtained through a combination of rigid and flexible nephroscopy, as well as antegrade ureteroscopy. The patient was left with a Double-J ureteral stent on a string for removal in 1 week. After overnight observation, his hemoglobin, white blood cell count, and renal function were normal and thus he was discharged home. The day after stent removal, he presented to the emergency department with abdominal pain, was found to have mild left hydronephrosis on CT, and was discharged on 1 week of antibiotics. One week later he re-presented with worsening abdominal pain and was found to have an elevated creatinine and a white blood cell count of 21 × 109/L. On contrasted CT with delayed images, an 18 cm splenic fluid collection was seen with a fistulous connection to the left kidney collecting system. He underwent emergent stent placement and improved clinically without drainage of the urinoma. A renal ultrasonography 1 month after stent placement confirmed resolution of the splenic urinoma, so the stent was removed at 1 month. Follow-up CT 1 month after stent removal was normal without any evidence of fistula or urinoma recurrence. Conclusion: This is the first report of a subcapsular splenic urinoma and splenorenal fistula post-PNL. Ureteral stent placement was sufficient for drainage and to resolve the complication.
Collapse
|
41
|
York NE, Borofsky MS, Chew BH, Dauw CA, Paterson RF, Denstedt JD, Razvi H, Nadler RB, Humphreys MR, Preminger GM, Nakada SY, Krambeck AE, Miller NL, Terry C, Rawlings LD, Lingeman JE. Randomized Controlled Trial Comparing Three Different Modalities of Lithotrites for Intracorporeal Lithotripsy in Percutaneous Nephrolithotomy. J Endourol 2017; 31:1145-1151. [PMID: 28859485 DOI: 10.1089/end.2017.0436] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE To compare the efficiency (stone fragmentation and removal time) and complications of three models of intracorporeal lithotripters in percutaneous nephrolithotomy (PCNL). MATERIALS AND METHODS Prospective, randomized controlled trial at nine centers in North America from 2009 to 2016. Patients were randomized to one of three lithotripter devices: the Cyberwand, a dual-probe ultrasonic device; the Swiss Lithoclast Select, a combination pneumatic and ultrasonic device; and the StoneBreaker, a portable pneumatic device powered by CO2 cartridges. Since the StoneBreaker lacks an ultrasonic component, it was used with the LUS-II ultrasonic lithotripter to allow fair comparison with combination devices. RESULTS Two hundred seventy patients were enrolled, 69 were excluded after randomization. Two hundred one patients completed the study: 71 in the Cyberwand group, 66 in the Lithoclast Select group, and 64 in the StoneBreaker group. The baseline patient characteristics of the three groups were similar. Mean stone surface area was smaller in the StoneBreaker group at 407.8 mm2 vs 577.5 mm2 (Lithoclast Select) and 627.9 mm2 (Cyberwand). The stone clearance rate was slowest in the StoneBreaker group at 24.0 mm2/min vs 28.9 mm2/min and 32.3 mm2/min in the Lithoclast Select and Cyberwand groups, respectively. After statistically adjusting for the smaller mean stone in the StoneBreaker group, there was no difference in the stone clearance rate among the three groups (p = 0.249). Secondary outcomes, including complications and stone-free rates, were similar between the groups. CONCLUSIONS The Cyberwand, Lithoclast Select, and the StoneBreaker lithotripters have similar adjusted stone clearance rates in PCNL for stones >2 cm. The safety and efficacy of these devices are comparable.
Collapse
|
42
|
Tom WR, Wollin DA, Jiang R, Radvak D, Simmons WN, Preminger GM, Lipkin ME. Next-Generation Single-Use Ureteroscopes: An In Vitro Comparison. J Endourol 2017; 31:1301-1306. [PMID: 28978227 DOI: 10.1089/end.2017.0447] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION Single-use ureteroscopes have been gaining popularity in recent years. We compare the optics, deflection, and irrigation flow of two novel single-use flexible ureteroscopes-the YC-FR-A and the NeoFlex-with contemporary reusable and single-use flexible ureteroscopes. METHODS Five flexible ureteroscopes, YC-FR-A (YouCare Tech, China), NeoFlex (Neoscope, Inc., USA), LithoVue (Boston Scientific, USA), Flex-Xc (Karl Storz, Germany), and Cobra (Richard Wolf, Germany), were assessed in vitro for image resolution, distortion, field of view, depth of field, color representation, and grayscale imaging. Ureteroscope deflection and irrigation were also compared. RESULTS The YC-FR-A showed a resolution of 5.04 lines/mm and 4.3% image distortion. NeoFlex showed a resolution of 17.9 lines/mm and 14.0% image distortion. No substantial difference was demonstrated regarding the other optic characteristics between the two. Across all tested ureteroscopes, single-use or reusable, the digital scopes performed best with regard to optics. The YC-FR-A had the greatest deflection at baseline, but lacks two-way deflection. The NeoFlex had comparable deflection at baseline to reusable devices. Both ureteroscopes had substantial loss of deflection with instruments in the working channel. The YC-FR-A had the greatest irrigation rate. The NeoFlex has comparable irrigation to contemporary ureteroscopes. CONCLUSIONS The YouCare single-use fiberoptic flexible ureteroscope and NeoFlex single-use digital flexible ureteroscope perform comparably to current reusable ureteroscopes, possibly making each a viable alternative in the future. Newer YouCare single-use flexible ureteroscopes with a digital platform and two-way deflection may be more competitive, while the NeoFlex devices are undergoing rapid improvement as well. Further testing is necessary to validate the clinical performance and utility of these ureteroscopes, given the wide variety of single-use devices under development.
Collapse
|
43
|
Cabrera FJ, Shin RH, Waisanen KM, Nguyen G, Wang C, Scales CD, Ferrandino MN, Preminger GM, Yoshizumi TT, Lipkin ME. Comparison of Radiation Exposure from Fixed Table Fluoroscopy to a Portable C-Arm During Ureteroscopy. J Endourol 2017. [PMID: 28622024 DOI: 10.1089/end.2017.0240] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
INTRODUCTION Current treatment practices within the field of endourology require the routine use of radiation exposure to provide adequate imaging during urologic procedures. One such procedure requiring repeated radiation exposure during treatment is ureteroscopy. We set out to compare estimated fluoroscopic radiation exposures employing fixed table and portable C-arm fluoroscopy. MATERIALS AND METHODS A cross-sectional dosimetry phantom model was placed supine on both fixed fluoroscopy and standard operating room tables. The models were then exposed to three separate 5-minute runs of fluoroscopic exposure. Metal oxide semiconductor field effect transistor dosimeters were utilized in organ-specific locations to determine specific radiation exposure dosages. Absorbed radiation was determined for each organ location for both fluoroscopy units. Organ dose volumetric corrections were performed for skin and red bone marrow, to correct for the nonirradiated portion. Organ dose rate (ODR, mGy/s) and effective dose rate (EDR, mSv/s) were calculated, with values reported as mean ± standard deviation. RESULTS There were found to be statistically significant elevations for both total EDR and organ-specific dose rates with the use of fixed table fluoroscopy compared with C-arm fluoroscopy. EDR was found to be 0.0240 ± 0.0019 mSv/s for the fixed table unit and 0.0029 ± 0.0005 mSv/s for the C-arm unit (p = 0.0024). Internal organs exposed to the most radiation during fixed table fluoroscopy included the gall bladder and stomach in comparison to C-arm fluoroscopy, which found elevated exposure in the kidneys, pancreas, and spleen. CONCLUSION The routine use of fixed table fluoroscopy results in significantly elevated estimated organ doses and EDR when directly compared with C-arm fluoroscopy in model trials. This difference should be taken into consideration by practicing urologists when patient treatment requires the use of fluoroscopy to maintain radiation exposure as low as reasonably achievable.
Collapse
|
44
|
Xing Y, Chen TT, Simmons WN, Sankin G, Cocks FH, Lipkin ME, Preminger GM, Zhong P. Comparison of Broad vs Narrow Focal Width Lithotripter Fields. J Endourol 2017; 31:502-509. [PMID: 28340536 DOI: 10.1089/end.2016.0560] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVE To investigate the impact of lithotripter focal width on stone fragmentation. MATERIALS AND METHODS A modified reflector was used to reduce -6 dB beam size of the HM3 lithotripter, while increasing concomitantly peak pressure. Fragmentation in vitro was assessed with modified and original reflectors using BegoStone phantoms. A membrane holder was used to mimic lithotripsy in vivo, and a matrix holder was used to assess variations of fragmentation power in the focal plane of the lithotripter field. Stone fragmentation in vivo produced by the two reflectors was further compared in a swine model. RESULTS Stone fragmentation in vitro after 500 (or 2000) shocks was ∼60% (or ∼82%) vs ∼40% (or ∼75%) with original and modified reflector, respectively (p ≤ 0.0016). Fragmentation power with the modified reflector was the highest on the lithotripter axis, but dropped rapidly in the lateral direction and became insignificant at radial distances >6.0 mm. Stone fragmentation with the original reflector was lower along the lithotripter axis, but fragmentation power decayed slowly in lateral direction, with appreciable fragmentation produced at 6.0 mm. Stone fragmentation efficiency in vivo after 500 (or 2000) shocks was ∼70% (or ∼90%) vs ∼45% (or ∼80%) with original and modified reflector, respectively (p ≤ 0.04). CONCLUSIONS A lithotripter field with broad beam size yields superior stone comminution when compared with narrow beam size under comparable effective acoustic pulse energy both in vivo and in vitro. These findings may facilitate future improvements in lithotripter design to maximize comminution efficiency while minimizing tissue injury.
Collapse
|
45
|
Youssef RF, Martin JW, Sakhaee K, Poindexter J, Vernez SL, Dutta R, Scales CD, Preminger GM, Lipkin ME. MP01-19 RECENT EPIDEMIOLOGICAL AND METABOLIC TRENDS IN STONE DISEASE: RISING HYPOCITRATURIA AND HYPEROXALURIA. J Urol 2017. [DOI: 10.1016/j.juro.2017.02.094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
46
|
Hobbs KT, Hammill B, Wollin D, Preminger GM, Lipkin ME, Schmader KE, Scales, Jr. CD. MP95-05 INCREASING UTILIZATION OF CARE FOR URINARY STONE DISEASE IN OLDER ADULTS. J Urol 2017. [DOI: 10.1016/j.juro.2017.02.3007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
47
|
Dale J, Kaplan AG, Radvak D, Shin R, Ackerman A, Chen T, Scales CD, Ferrandino MN, Simmons WN, Preminger GM, Lipkin ME. Evaluation of a Novel Single-Use Flexible Ureteroscope. J Endourol 2017; 35:903-907. [PMID: 27981862 DOI: 10.1089/end.2016.0237] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Introduction: A novel single-use flexible ureteroscope promises the optical characteristics and maneuverability of a reusable fourth-generation flexible ureteroscope. In this study, the LithoVue Single-Use Digital flexible ureteroscope was directly compared with contemporary reusable flexible ureteroscopes, with regard to optics, deflection, and irrigation flow. Methods: Three flexible ureteroscopes such as the LithoVue (Single Use; Boston Scientific), Flex-Xc (Karl Storz, Germany), and Cobra (Richard Wolf, Germany) were assessed in vitro for image resolution, distortion, color representation, grayscale imaging, field of view, and depth of field. Ureteroscope deflection was tested with an empty channel followed by placement of a 200 μm laser fiber and a 1.9F wire basket, a 2.0F nanoelectric pulse lithotripsy (NPL) probe, and a 2.4F NPL probe. Ureteroscope irrigation flow was measured using normal saline at 100 cm, with an empty channel followed by a 200 μm laser fiber, a 1.9F wire basket and a 2.0F NPL probe. Results: The LithoVue showed the largest field of view, with excellent resolution, image distortion, and depth of field. No substantial difference was demonstrated in color reproducibility or in the discernment of grayscales between ureteroscopes. The LithoVue maintained full deflection ability with all instruments in the working channel, although the Flex-Xc and Cobra ureteroscopes showed loss of deflection ranging from 2° to 27°, depending on the instrument placed. With an empty channel, the LithoVue showed an absolute flow rate similar to the Flex-Xc ureteroscope (p = 0.003). It maintained better flow with instruments in the channel than the Flex-Xc ureteroscope. The Cobra ureteroscope has a separate 3.3F instrument channel, keeping flow rates the same with instrument insertion. Conclusion: The LithoVue Single-Use Digital ureteroscope has comparable optical capabilities, deflection, and flow, making it a viable alternative to standard reusable fourth-generation flexible digital and fiberoptic ureteroscopes.
Collapse
|
48
|
Kaplan AG, Chen TT, Sankin G, Yang C, Dale JA, Simmons WN, Zhong P, Preminger GM, Lipkin ME. Comparison of the Nanopulse Lithotripter to the Holmium Laser: Stone Fragmentation Efficiency and Impact on Flexible Ureteroscope Deflection and Flow. J Endourol 2016; 30:1150-1154. [PMID: 27736195 DOI: 10.1089/end.2016.0228] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
INTRODUCTION The Nanopulse Lithotripter (NPL; Lithotech Medical, Israel) is a novel intracorporeal device that uses a nanosecond duration electrical discharge through a reusable flexible coaxial probe to endoscopically fragment urinary stones. This device was compared with a holmium laser lithotripsy (HoL) with regard to stone fragmentation efficiency (SFE) and its impact on flexible ureteroscope (URS) deflection and flow of irrigation. METHODS Using a custom bench model, a 6 mm BegoStone cylindrical phantom (mixture 5:2) was confined under 0.9% saline atop sequential mesh sieves. The SFE of two NPL probe sizes (2.0F, 3.6F) and two HoL fibers (200, 365 μm) was evaluated using concordant settings of 1 J and 5 Hz. URS deflection and irrigation flow with NPL probes in the working channel were tested in five new fourth generation flexible URS and compared with other adjunct endourologic instruments. RESULTS The 2.0F NPL showed improved SFE compared with the 200 μm laser (86 mg/min vs 52 mg/min, p = 0.014) as did the 3.6F NPL vs the 365 μm laser (173 mg/min vs 80 mg/min, p = 0.05). The NPL created more 1 to 2 mm fragments; the laser created more dust. URS deflection reduced by 3.75° with the 2.0 NPL probe. URS irrigation flow reduced from 36.5 to 6.3 mL/min with the 2.0F NPL probe. CONCLUSION NPL shows improved SFE compared with HoL. Flow with the 2.0F probe is akin to a stone basket. NPL offers an effective alternative to HoL.
Collapse
|
49
|
Assimos D, Krambeck A, Miller NL, Monga M, Murad MH, Nelson CP, Pace KT, Pais VM, Pearle MS, Preminger GM, Razvi H, Shah O, Matlaga BR. Surgical Management of Stones: American Urological Association/Endourological Society Guideline, PART I. J Urol 2016; 196:1153-60. [DOI: 10.1016/j.juro.2016.05.090] [Citation(s) in RCA: 368] [Impact Index Per Article: 46.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/23/2016] [Indexed: 12/17/2022]
|
50
|
Ghani KR, Andonian S, Bultitude M, Desai M, Giusti G, Okhunov Z, Preminger GM, de la Rosette J. Percutaneous Nephrolithotomy: Update, Trends, and Future Directions. Eur Urol 2016; 70:382-96. [DOI: 10.1016/j.eururo.2016.01.047] [Citation(s) in RCA: 122] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2015] [Accepted: 01/28/2016] [Indexed: 12/24/2022]
|