26
|
Attizzani GF, Dallan LAP, Forrest JK, Reardon MJ, Szeto WY, Liu F, Pelletier M. Redo-transcatheter aortic valve replacement with the supra-annular, self-expandable Evolut platform: Insights from the Transcatheter valve Therapy Registry. Catheter Cardiovasc Interv 2021; 99:869-876. [PMID: 34533891 DOI: 10.1002/ccd.29941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 08/23/2021] [Indexed: 11/09/2022]
Abstract
OBJECTIVES To assess the safety profile of redo-TAVR procedures from patients in the transcatheter valve therapy (TVT) Registry. BACKGROUND The use of transcatheter aortic valves (TAV) to treat previously implanted failing TAVS (TAV-in-TAV) has been an increasingly important topic as indications for TAVR move to younger and lower-risk patients, but data on the safety and efficacy of redo-TAVR is limited. METHODS Patients undergoing redo-TAVR procedures using the Evolut R, Evolut PRO or Evolut PRO+ valve in the TVT Registry between April 2015 and March 2020 were included. In-hospital, 30-day and 1-year outcomes were analyzed. RESULTS Redo-TAVR was performed in 292 patients (213 patients received the Evolut R valve and 79 received the Evolut PRO or PRO+ valve). Device success was achieved in 94.5%. In-hospital mortality was 2.1%, stroke occurred in 2.7%, and 77.2% of patients were discharged home. There were no cases of coronary compression/obstruction or myocardial infarction that occurred in index hospitalization. Mean gradient at 30-days was 11.9 ± 6.9 mmHg, and 73.1% had none/trace total aortic regurgitation. CONCLUSIONS Results from the TVT Registry demonstrate good short-term outcomes after redo-TAVR with the supra-annular, self-expandable Evolut platform. Long-term follow-up is necessary to further expand understanding this complex scenario.
Collapse
|
27
|
Tsushima T, Al-Kindi SG, Wheat HL, Fares A, Attizzani GF, Baeza CR, Pelletier MP, Arruda MS, Mackall JA, Thal SG. B-PO02-039 CLINICAL IMPACT OF RIGHT VENTRICULAR PACING BURDEN IN PATIENTS WITH NEWLY IMPLANTED PACEMAKER AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: SINGLE HIGH VOLUME CENTER EXPERIENCE. Heart Rhythm 2021. [DOI: 10.1016/j.hrthm.2021.06.295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
Filby SJ, Dallan LAP, Cochet A, Kobayashi A, Attizzani GF, Rashid I, Rajagopalan S, Arruda M, Shishehbor M, Bezerra HG. Left Atrial Appendage Occlusion Using Cardiac Computed Tomography Angiography and Intracardiac Echocardiography: A Prospective, Single-Center Study. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2021. [DOI: 10.1016/j.carrev.2021.06.102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
29
|
Tsushima T, Al-Kindi S, Nadeem F, Attizzani GF, Elgudin Y, Markowitz A, Costa MA, Simon DI, Arruda MS, Mackall JA, Thal SG. Machine Learning Algorithms for Prediction of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement. Circ Arrhythm Electrophysiol 2021; 14:e008941. [PMID: 33685208 DOI: 10.1161/circep.120.008941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
30
|
Arora S, Lahewala S, Zuzek Z, Thakkar S, Jani C, Jaswaney R, Singh A, Bhyan P, Arora N, Main A, Osman MN, Hoit BD, Attizzani GF, Panaich SS. Transcatheter aortic valve replacement in aortic regurgitation: The U.S. experience. Catheter Cardiovasc Interv 2020; 98:E153-E162. [DOI: 10.1002/ccd.29379] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 09/17/2020] [Accepted: 10/23/2020] [Indexed: 11/09/2022]
|
31
|
Attizzani GF, Dallan LAP, Markowitz A, Yakubov SJ, Deeb GM, Reardon MJ, Forrest JK, Mangi AA, Huang J, Popma JJ. Impact of Repositioning on Outcomes Following Transcatheter Aortic Valve Replacement With a Self-Expandable Valve. JACC Cardiovasc Interv 2020; 13:1816-1824. [PMID: 32763073 DOI: 10.1016/j.jcin.2020.04.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 04/08/2020] [Accepted: 04/14/2020] [Indexed: 11/18/2022]
Abstract
OBJECTIVES This study sought to compare outcomes following transcatheter aortic valve replacement when valve repositioning was performed (repositioned group) versus procedures without repositioning (nonrepositioned group). BACKGROUND The Evolut R and Evolut PRO valves were designed to allow repositioning during deployment, yet the effect of repositioning on clinical outcomes remains unclear. METHODS Patients implanted with the Evolut R or PRO valve from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial continued access study and the Evolut Low Risk Trial between June 2016 and November 2018 were combined. Baseline multidetector computed tomography data were analyzed for the Evolut Low Risk Trial patients. The primary outcomes were the rate of all-cause mortality and the rate of disabling stroke 30 days. Secondary outcomes were per Valve Academic Research Consortium-2. RESULTS The Evolut R or PRO valve was implanted in 946 patients, and repositioning was performed in 318 (33.6%). Compared with patients in the nonrepositioned group, patients in the repositioned group had lower Society of Thoracic Surgeons score (2.3 ± 1.3% vs. 2.6 ± 1.4%; p < 0.001) and fewer prior percutaneous coronary interventions (11.9% vs. 19.7%; p = 0.003). There were no differences in baseline multidetector computed tomography parameters between groups. There were no differences in the primary outcome of death (0.3% vs. 0.3%; p = 0.99) or disabling stroke (0.3% vs. 0.5%; p = 0.71) at 30 days or 1 year (1.9% vs. 2.9%; p = 0.44; and 0.8% vs. 0.9%%; p = 0.79, respectively). CONCLUSIONS The utilization of the repositioning feature of the Evolut valves was safe, and no differences in death or disabling stroke were observed at 30 days or 1 year between groups. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283; Safety and Efficacy Study of the Medtronic CoreValve® System In the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).
Collapse
|
32
|
Ichibori Y, Puri R, Taramasso M, Nietlispach F, Attizzani GF, Meier B, Auffret V, Le Breton H, Cavalcante JL, Das R, Bhatt DL, Kapadia SR, Kalra A. An Optimized Approach for Transfemoral Transcatheter Aortic Valve Implantation: A Comprehensive Review and Current Evidence. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 21:1034-1040. [DOI: 10.1016/j.carrev.2019.12.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2019] [Revised: 12/10/2019] [Accepted: 12/31/2019] [Indexed: 12/17/2022]
|
33
|
Lipinski J, Patel SM, Patel TR, Kobe D, Saric P, Panhwar M, Nadeem F, Li J, Clevenger JR, Ichibori Y, Fares A, Lang K, Bezerra HG, Sareyyupoglu B, Medalion B, Deo S, Elgudin Y, Markowitz A, Simon DI, Costa MA, Kalra A, Attizzani GF. Transcatheter Valve Implantation for Failed Surgical Aortic and Mitral Bioprostheses: A Single-Center Experience. THE JOURNAL OF INVASIVE CARDIOLOGY 2020; 32:186-193. [PMID: 32160153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
OBJECTIVES We share our center's experience with the use of transcatheter valvular therapies in the setting of failed bioprostheses. BACKGROUND As medicine continues to advance, the lifespan of individuals continues to increase, and current surgical valvular therapies begin to degrade prior to a person's end of life. It is important to evaluate the efficacy and durability of transcatheter valves within failed surgical bioprostheses. METHODS Baseline characteristics, periprocedural complications, and long-term outcomes were collected and assessed in patients who received transcatheter valves for failing surgical aortic valve bioprostheses and mitral valve and ring bioprostheses from March 2011 to July 2018. RESULTS From our cohort of 1048 patients, we identified 45 individuals (4.3%) who underwent transcatheter replacement of a failed bioprosthetic valve or ring. Mean age at presentation was 80.8 ± 10.7 years and 75.5 ± 9.3 years, mean STS score was 9.3 ± 5.1 and 13.3 ± 8.7, and mean time to failure was 12.0 ± 5.2 years and 7.3 ± 4.5 years for aortic and mitral positions, respectively. At 1 year, time to event analysis suggested a 16.4% mortality rate for aortic replacement and 12.8% mortality rate for mitral replacement. CONCLUSIONS We demonstrate outcomes from one of the largest single-center United States based cohorts of transcatheter replacements of failed surgical bioprostheses. Our center has demonstrated that it is feasible to pursue the replacement of failed surgical bioprostheses in the aortic and mitral positions with transcatheter valves given appropriate patient selection.
Collapse
|
34
|
Cavallo AU, Patterson AJ, Thomas R, Alaiti MA, Attizzani GF, Laukamp K, Große Hokamp N, Bezerra H, Gilkeson R, Rajagopalan S. Low dose contrast CT for transcatheter aortic valve replacement assessment: Results from the prospective SPECTACULAR study (spectral CT assessment prior to TAVR). J Cardiovasc Comput Tomogr 2020; 14:68-74. [DOI: 10.1016/j.jcct.2019.06.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 06/06/2019] [Accepted: 06/23/2019] [Indexed: 11/16/2022]
|
35
|
Pereira GTR, La Manna A, Ichibori Y, Vergara-Martel A, Ramos Nascimento B, Samdani AJ, Capodanno D, D'Agosta G, Gravina G, Venuti G, Tamburino C, F Attizzani G. Optical coherence tomography evaluation of the absorb bioresorbable scaffold performance for overlap versus non-overlap segments in patients with coronary chronic total occlusion: insight from the GHOST-CTO registry. Int J Cardiovasc Imaging 2019; 35:1767-1776. [PMID: 31175527 DOI: 10.1007/s10554-019-01636-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Accepted: 05/27/2019] [Indexed: 01/18/2023]
Abstract
The Absorb bioresorbable vascular scaffold (BVS) promised to avoid some of the disadvantages of its metal predecessors. Even though it has been taken off the market, limited data is available about its use in coronary chronic total occlusion (CTO) and its performance in overlap segments, which would be of special research interest due to its large thickness. This data is still pertinent since the platform of bioresorbable devices has not been abandoned, with several companies working on it. We aimed to compare healing and performance between overlap (OL) and non-overlap regions (NOL) of CTO lesions treated with BVS, using optical coherence tomography (OCT). Fourteen patients with overlapping BVS were included from the GHOST-CTO registry, resulting in 25 OL and 38 NOL regions. OCT based parameters were compared between OL and NOL groups at baseline (post-implantation) and 12-month follow-up. The mean age was 61.7 ± 7.2 years and 12 (86%) were males. Twelve (86%) patients underwent PCI for stable coronary artery disease and 2 (14%) had unstable angina. At 12-month follow-up, mean lumen area decreased in both NOL and OL regions, but the decrease was significantly larger in the OL region (NOL - 0.7 ± 1.33 vs. OL - 2.4 ± 1.54 mm2; p = 0.002). Mean scaffold area increased in both regions, but increased significantly more in NOL ( + 1.1 ± 1.54 vs. + 0.4 ± 1.16 mm2; p = 0.016). The percent of uncovered struts was lower in the OL group (5.0 ± 6.6% vs. 3.75 ± 8.7%, p = 0.043), whereas the percentage of malapposed struts was similar (0.3 ± 0.5% vs. 0.7 ± 2.3%, p = 0.441). Neointimal hyperplasia (NIH) was more pronounced in the OL region (0.13 ± 0.04 vs. 0.24 ± 0.10 mm2, p = 0.001). The OL and NOL segments showed comparable healing in terms of coverage and malapposition. However, NIH was more prominent in OL region. The long-term clinical implications of these findings needs further evaluation. The present study provides important insights for future development of BVS technology.
Collapse
|
36
|
Ichibori Y, Li J, Davis A, Patel TM, Lipinski J, Panhwar M, Saric P, Qureshi G, Patel SM, Sareyyupoglu B, Markowitz AH, Bezerra HG, Costa MA, Zidar DA, Kalra A, Attizzani GF. Feasibility and Safety of Adopting Next-Day Discharge as First-Line Option After Transfemoral Transcatheter Aortic Valve Replacement. THE JOURNAL OF INVASIVE CARDIOLOGY 2019; 31:64-72. [PMID: 30819977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
OBJECTIVES Data on next-day discharge (NDD) after transcatheter aortic valve replacement (TAVR) are limited. This study investigated the feasibility and safety of NDD as a first-line option (the very-early discharge [VED] strategy) compared with the early-discharge (ED) strategy (2-3 days as a first-line option) after TAVR. METHODS We reviewed 611 consecutive patients who had minimalist TAVR (transfemoral approach under conscious sedation) and no in-hospital mortality; a total of 418 patients underwent ED strategy (since December 2013) and 193 patients underwent VED strategy (as part of a hospital initiative to reduce length of stay, since August 2016). NDD in the VED strategy was performed with heart team consensus in patients without significant complications. The primary outcome was a composite of 30-day all-cause mortality/rehospitalization. RESULTS Sixty-five patients (33.7%) in the VED strategy and 10 patients (2.4%) in the ED strategy were discharged the next day (P<.001). NDD patients had received balloon-expandable (n = 30) or self-expanding valves (n = 45) and showed a similar primary outcome rate compared with non-NDD patients. After adjustment using propensity score matching (172 pairs), post-TAVR length of stay was significantly shorter in the VED group (3.2 ± 3.1 days) than in the ED group (3.5 ± 2.7 days; P<.01). The primary outcome did not differ between the two groups (7.0% vs 11.6%; P=.14), with comparable 30-day mortality rate (1.2% vs 2.3%; P=.68) and rehospitalization rate (5.8% vs 11.1%; P=.08). CONCLUSIONS Utilization of NDD as a first-line option after minimalist TAVR is feasible and safe, and leads to further reduction in length of stay compared with an ED strategy.
Collapse
|
37
|
Li J, Patel SM, Nadeem F, Thakker P, Al-Kindi S, Thomas R, Makani A, Hornick JM, Patel T, Lipinski J, Ichibori Y, Davis A, Markowitz AH, Bezerra HG, Simon DI, Costa MA, Kalra A, Attizzani GF. Impact of residual coronary atherosclerosis on transfemoral transcatheter aortic valve replacement. Catheter Cardiovasc Interv 2019; 93:545-552. [PMID: 30312990 DOI: 10.1002/ccd.27894] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 06/13/2018] [Accepted: 08/29/2018] [Indexed: 01/09/2023]
Abstract
OBJECTIVES This study reports on the clinical effects of complete vs incompletely revascularized coronary artery disease on transcatheter aortic valve replacement (TAVR). BACKGROUND There is a high prevalence of active coronary artery disease (CAD) in patients undergoing TAVR but preemptive revascularization remains controversial. METHODS Patients were categorized into three cohorts: complete revascularization (CR), incomplete revascularization of a major epicardial artery (IR Major), and incomplete revascularization of a minor epicardial artery only (IR Minor). When feasible, SYNTAX scoring was performed for exploratory analysis. Analyses were performed using Cox proportional hazard models and Kaplan-Meier method. RESULTS A total of 323 patients with active CAD were included. Adjusted outcomes showed that patients with IR Major had increased incidence of acute myocardial infarction (AMI) or revascularization compared with those in the CR cohort (HR 3.72, P = 0.048). No difference was noted in all-cause mortality or all-cause readmission rates. Exploratory secondary analysis with residual SYNTAX scores showed a significant interaction between disease burden and AMI/revascularization, as well as all-cause readmission. All-cause mortality remained unaffected based on residual SYNTAX scores. CONCLUSIONS This is a retrospective single-center study reporting on pre-TAVR revascularization outcomes in patients with active CAD. In this analysis, we found that patients undergoing TAVR benefited from achieving complete revascularization to abate future incidence of AMI/revascularization. Despite this finding, all-cause mortality remained unaffected. Future efforts should focus on the role of functional assessment of the coronaries, as well as the long-term effects of complete revascularization in a larger patient cohort.
Collapse
|
38
|
Ichibori Y, Li J, Patel T, Lipinski J, Ladas T, Saric P, Kobe D, Tsushima T, Peters M, Patel S, Davis A, Markowitz AH, Bezerra HG, Costa MA, Kalra A, Attizzani GF. Short-Term and Long-Term Outcomes of Patients Undergoing Urgent Transcatheter Aortic Valve Replacement Under a Minimalist Strategy. THE JOURNAL OF INVASIVE CARDIOLOGY 2019; 31:E30-E36. [PMID: 30700628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
OBJECTIVES Urgent transcatheter aortic valve replacement (TAVR) is associated with worse short-term outcomes compared with elective TAVR; however, little is known about long-term outcomes or the safety of the minimalist strategy in this setting. This study investigated the short-term and long-term outcomes of urgent TAVR compared with elective TAVR under a minimalist strategy (transfemoral [TF] approach with conscious sedation and no transesophageal echocardiography guidance). METHODS After excluding 2 emergent patients requiring immediate procedures, a total of 474 consecutive patients underwent elective TF-TAVR (396 patients; 83.6%) or urgent TF-TAVR (78 patients; 16.4%). Urgent TAVR was defined as a procedure performed in the same hospitalization in patients emergently admitted due to cardiac arrest, severe acute decompensated heart failure, acute coronary syndrome, or repeated syncopal episodes. RESULTS A minimalist approach was used in 77 patients (98.7%) undergoing urgent TAVR and in 392 patients (99.0%) undergoing elective TAVR (P=.59). Urgent TAVR had similar procedure-related complications, such as stroke, myocardial infarction, bleeding or vascular complications, and in-hospital mortality compared with elective TAVR (mortality, 1.3% vs 0.8%; P=.51) with no intraprocedural cross-over from conscious sedation to general anesthesia. However, 30-day and 1-year survival rates were reduced in patients undergoing urgent TAVR. After adjustment with baseline and procedural factors, urgent TAVR remained significantly predictive of 1-year mortality (adjusted hazard ratio, 2.26; 95% confidence interval, 1.16-4.23; P=.01). CONCLUSIONS Urgent minimalist TAVR can be safely performed with favorable in-hospital outcomes, while increased 30-day and 1-year mortality rates suggest the importance of appropriate diagnosis and timely treatment of severe aortic stenosis.
Collapse
|
39
|
Attizzani GF, Patel SM, Dangas GD, Szeto WY, Sorajja P, Reardon MJ, Popma JJ, Kodali S, Chenoweth S, Costa MA. Comparison of Local Versus General Anesthesia Following Transfemoral Transcatheter Self-Expanding Aortic Valve Implantation (from the Transcatheter Valve Therapeutics Registry). Am J Cardiol 2019; 123:419-425. [PMID: 30527797 DOI: 10.1016/j.amjcard.2018.10.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 10/24/2018] [Accepted: 10/25/2018] [Indexed: 10/27/2022]
Abstract
Transfemoral transcatheter aortic valve replacement (TF-TAVR) is mostly performed under general anesthesia (GA) in most US centers. We examined in-hospital and 30-day outcomes in patients who underwent TF-TAVR with a self-expanding bioprosthesis using local anesthesia (LA) or GA. Patients from the Transcatheter Valve Therapeutics Registry who underwent TF-TAVR from January 2014 to June 2016 with LA or GA were evaluated. Propensity matching was performed and procedural and clinical outcomes compared up to 30 days. A total of 11,006 patients were included (GA: 8,239 [74.9%] and LA: 2,767 [25.1%]). After propensity matching (n = 1,988 matched sets), device success was similar (94.5% vs 94.6%, p = 0.905). No differences in in-hospital stroke (2.7% vs 2.3%, p = 0.413) or paravalvular regurgitation grade (p = 0.113) were noted. Fewer LA patients were converted to open heart surgery (0.2% vs 0.6%, p = 0.076) or experienced an in-hospital major vascular complication (0.7% vs 1.4%, p = 0.026). Intensive care unit time (40.1 ± 58.4 vs 50.9 ± 72.1 hours, p < 0.001) and postprocedure length of stay (4.1 ± 3.6 vs 5.0 ± 4.5 days, p < 0.001) were significantly shorter with LA. In-hospital and 30-day all-cause mortality were lower in the LA cohort compared to the GA cohort ([1.1% vs 2.7%, p < 0.001] and [2.1% vs 3.9%, p = 0.001]). In conclusion, in the largest series of self-expanding bioprostheses for TF-TAVR, these propensity-matched cohorts demonstrate that LA is an acceptable alternative to GA with comparable success, lower safety outcomes, complications rates, and in-hospital and 30-day all-cause mortality.
Collapse
|
40
|
Yoon SH, Whisenant BK, Bleiziffer S, Delgado V, Dhoble A, Schofer N, Eschenbach L, Bansal E, Murdoch DJ, Ancona M, Schmidt T, Yzeiraj E, Vincent F, Niikura H, Kim WK, Asami M, Unbehaun A, Hirji S, Fujita B, Silaschi M, Tang GHL, Kuwata S, Wong SC, Frangieh AH, Barker CM, Davies JE, Lauten A, Deuschl F, Nombela-Franco L, Rampat R, Nicz PFG, Masson JB, Wijeysundera HC, Sievert H, Blackman DJ, Gutierrez-Ibanes E, Sugiyama D, Chakravarty T, Hildick-Smith D, de Brito FS, Jensen C, Jung C, Smalling RW, Arnold M, Redwood S, Kasel AM, Maisano F, Treede H, Ensminger SM, Kar S, Kaneko T, Pilgrim T, Sorajja P, Van Belle E, Prendergast BD, Bapat V, Modine T, Schofer J, Frerker C, Kempfert J, Attizzani GF, Latib A, Schaefer U, Webb JG, Bax JJ, Makkar RR. Outcomes of transcatheter mitral valve replacement for degenerated bioprostheses, failed annuloplasty rings, and mitral annular calcification. Eur Heart J 2018; 40:441-451. [DOI: 10.1093/eurheartj/ehy590] [Citation(s) in RCA: 201] [Impact Index Per Article: 33.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 09/06/2018] [Indexed: 11/14/2022] Open
|
41
|
Nakamura D, Wijns W, Price MJ, Jones MR, Barbato E, Akasaka T, Lee SWL, Patel SM, Nishino S, Wang W, Gopinath A, Attizzani GF, Holmes D, Bezerra HG. New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome. JACC Cardiovasc Interv 2018; 11:1467-1478. [DOI: 10.1016/j.jcin.2018.06.049] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 06/27/2018] [Accepted: 06/28/2018] [Indexed: 10/28/2022]
|
42
|
Bangalore S, Bezerra HG, Rizik DG, Armstrong EJ, Samuels B, Naidu SS, Grines CL, Foster MT, Choi JW, Bertolet BD, Shah AP, Torguson R, Avula SB, Wang JC, Zidar JP, Maksoud A, Kalyanasundaram A, Yakubov SJ, Chehab BM, Spaedy AJ, Potluri SP, Caputo RP, Kondur A, Merritt RF, Kaki A, Quesada R, Parikh MA, Toma C, Matar F, DeGregorio J, Nicholson W, Batchelor W, Gollapudi R, Korngold E, Sumar R, Chrysant GS, Li J, Gordon JB, Dave RM, Attizzani GF, Stys TP, Gigliotti OS, Murphy BE, Ellis SG, Waksman R. The State of the Absorb Bioresorbable Scaffold: Consensus From an Expert Panel. JACC Cardiovasc Interv 2018; 10:2349-2359. [PMID: 29216997 DOI: 10.1016/j.jcin.2017.09.041] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Revised: 08/31/2017] [Accepted: 09/21/2017] [Indexed: 12/26/2022]
Abstract
Significant progress has been made in the percutaneous coronary intervention technique from the days of balloon angioplasty to modern-day metallic drug-eluting stents (DES). Although metallic stents solve a temporary problem of acute recoil following balloon angioplasty, they leave behind a permanent problem implicated in very late events (in addition to neoatherosclerosis). BRS were developed as a potential solution to this permanent problem, but the promise of these devices has been tempered by clinical trials showing increased risk of safety outcomes, both early and late. This is not too dissimilar to the challenges seen with first-generation DES in which refinement of deployment technique, prolongation of dual antiplatelet therapy, and technical iteration mitigated excess risk of very late stent thrombosis, making DES the treatment of choice for coronary artery disease. This white paper discusses the factors potentially implicated in the excess risks, including the scaffold consideration and deployment technique, and outlines patient and lesion selection, implantation technique, and dual antiplatelet therapy considerations to potentially mitigate this excess risk with the first-generation thick strut Absorb scaffold (Abbott Vascular, Abbott Park, Illinois). It remains to be seen whether these considerations together with technical iterations will ultimately close the gap between scaffolds and metal stents for short-term events while at the same time preserving options for future revascularization once the scaffold bioresorbs.
Collapse
|
43
|
Guagliumi G, Shimamura K, Sirbu V, Garbo R, Boccuzzi G, Vassileva A, Valsecchi O, Fiocca L, Canova P, Colombo F, Tensol Rodriguez Pereira G, Nakamura D, Attizzani GF, Cereda A, Satogami K, De Luca L, Saia F, Capodanno D. Temporal course of vascular healing and neoatherosclerosis after implantation of durable- or biodegradable-polymer drug-eluting stents. Eur Heart J 2018; 39:2448-2456. [DOI: 10.1093/eurheartj/ehy273] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Accepted: 04/24/2018] [Indexed: 11/14/2022] Open
|
44
|
Attizzani GF, Al-Kindi SG, Dalton JE, Alkhalil A, DeCicco A, Mayuga M, Funderburg NT, Blackstone EH, Parikh S, Longenecker CT, Lederman MM, Simon DI, Costa MA, Zidar DA. Anisocytosis and leukocytosis are independently related to survival after transcatheter aortic valve replacement. J Cardiovasc Med (Hagerstown) 2018; 19:191-194. [DOI: 10.2459/jcm.0000000000000624] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
45
|
Younes A, Attizzani GF, Kalra A. Transcatheter Heart Valve Thrombosis: Incidence, Predictors, And Clinical Outcomes. US CARDIOLOGY REVIEW 2018. [DOI: 10.15420/usc.2017:32:2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Since its initial approval, the number of transcatheter aortic valve replacement procedures performed has increased exponentially with evolving indications that now include patients at intermediate risk for perioperative mortality following surgery. Multiple studies and reports have observed the phenomenon of leaflet dysfunction and thrombosis on follow-up imaging that may be associated with serious adverse outcomes. This review provides an insight into the incidence, predictors, management, and follow-up of transcatheter heartvalve thrombosis.
Collapse
|
46
|
Kalra A, Raza S, Puri R, Deo SV, Auffret V, Khera S, Attizzani GF, Zia A, Khan MS, Reardon MJ, Kleiman NS, Latib A, Rodés-Cabau J, Sabik JF, Bhatt DL. Subclinical Leaflet Thrombosis and Clinical Outcomes after TAVR: A Systematic Review and Meta-Analysis. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM 2018. [DOI: 10.1080/24748706.2018.1440678] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
47
|
Alkhalil A, Golbari S, Song D, Lamba H, Fares A, Alaiti A, Deo S, Attizzani GF, Ibrahim H, Ruiz CE. In-hospital outcomes of transcatheter versus surgical aortic valve replacement in end stage renal disease. Catheter Cardiovasc Interv 2017; 92:757-765. [DOI: 10.1002/ccd.27433] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Revised: 08/30/2017] [Accepted: 10/31/2017] [Indexed: 11/08/2022]
|
48
|
Nakamura D, Attizzani GF, Toma C, Sheth T, Wang W, Soud M, Aoun R, Tummala R, Leygerman M, Fares A, Mehanna E, Nishino S, Fung A, Costa MA, Bezerra HG. Failure Mechanisms and Neoatherosclerosis Patterns in Very Late Drug-Eluting and Bare-Metal Stent Thrombosis. Circ Cardiovasc Interv 2017; 9:CIRCINTERVENTIONS.116.003785. [PMID: 27582113 DOI: 10.1161/circinterventions.116.003785] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 07/25/2016] [Indexed: 01/25/2023]
Abstract
BACKGROUND There are few clinical studies on the pathophysiological mechanisms of very late stent thrombosis (VLST). We report optical coherence tomography findings in patients with VLST and compare the findings between bare-metal stents (BMS) and drug-eluting stents (DES). METHODS AND RESULTS We conducted a registry of stent thrombosis at 4 North American centers with optical coherence tomography imaging programs SAFE registry (The Study of Late Stent Failure Evaluated by OCT). Images were acquired in 61 patients (42 DES and 19 BMS) presenting with definite VLST. The median duration from implantation to VLST presentation was 51.4 months in the DES and 69.9 months in the BMS group (P=0.011). Uncovered and malapposed struts were observed in 70.5% (43/61) and 62.3% (38/61) of patients, respectively, whereas neoatherosclerosis was revealed in 49.2% (30/61). Stent underexpansion was observed in 42.4% of patients. Malapposed struts and stent underexpansion were more frequently demonstrated in DES than in BMS patients, whereas neoatherosclerosis was frequently observed in BMS (40.5% in DES and 68.4% in BMS; P=0.056). The percentage of frames with neoatherosclerosis was lower in DES than in BMS (15.56% [12.24-28.57] versus, 56.41% [40.74-70.00], respectively; P<0.001). Maximum consecutive lipid neointima length was shorter in DES than in BMS (2.4 [1.2-3.6] and 5.3 [3.0-7.0] mm; P=0.011). CONCLUSIONS Optical coherence tomography imaging demonstrated that VLST in DES and BMS had a wide variety of abnormal findings, such as neoatherosclerosis, uncovered strut, and malapposed strut. Neoatherosclerosis and lipid neointima were more frequently observed and had more longitudinal extension in BMS compared with DES.
Collapse
|
49
|
Vergara-Martel A, Tensol Rodrigues Pereira G, Bezerra HG, Mehanna E, Attizzani GF. Optical Coherence Tomography Assessment Prevented Unnecessary Intervention in an “Ambiguous” Angiographic Image. JACC Cardiovasc Interv 2017; 10:2338-2339. [DOI: 10.1016/j.jcin.2017.07.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 07/11/2017] [Indexed: 11/16/2022]
|
50
|
Kala P, Cervinka P, Jakl M, Kanovsky J, Kupec A, Spacek R, Kvasnak M, Poloczek M, Cervinkova M, Bezerra H, Valenta Z, Attizzani GF, Schnell A, Hong L, Costa MA. OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up. Int J Cardiol 2017; 250:98-103. [PMID: 29079414 DOI: 10.1016/j.ijcard.2017.10.059] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 10/11/2017] [Accepted: 10/17/2017] [Indexed: 11/17/2022]
Abstract
AIMS To assess the possible merits of optical coherence tomography (OCT) guidance in primary percutaneous coronary intervention (pPCI). METHODS AND RESULTS 201 patients with ST-elevation myocardial infarction (STEMI) were enrolled in this study. Patients were randomized either to pPCI alone (angio-guided group, n=96) or to pPCI with OCT guidance (OCT-guided group, n=105) and also either to biolimus A9 or to everolimus-eluting stent implantation. All patients were scheduled for nine months of follow-up angiography and OCT study. OCT guidance led to post-pPCI optimization in 29% of cases (59% malapposition and 41% dissections). No complications were found related to the OCT study. OCT analysis at nine months showed significantly less in-segment area of stenosis (6% [-11, 19] versus 18% [3, 33]; p=0.0002) in favor of the OCT-guided group. The rate major adverse cardiovascular events were comparable at nine months in both groups (3% in the OCT group versus 2% in the angio-guided group; p=0.87). CONCLUSIONS This study demonstrates the safety of OCT guidance during pPCI. The use of OCT optimized stent deployment in 1/3 of patients in this clinical scenario and significantly reduced in-segment area of stenosis at nine months of follow-up. Whether such improvements in OCT endpoints will have a positive impact on late clinical outcomes, they demand both a larger and longer-term follow-up study.
Collapse
|