51
|
Bhattarai A, Mäkelä JTA, Pouran B, Kröger H, Weinans H, Grinstaff MW, Töyräs J, Turunen MJ. Effects of human articular cartilage constituents on simultaneous diffusion of cationic and nonionic contrast agents. J Orthop Res 2021; 39:771-779. [PMID: 32767676 PMCID: PMC8048551 DOI: 10.1002/jor.24824] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 07/03/2020] [Accepted: 08/05/2020] [Indexed: 02/04/2023]
Abstract
Contrast-enhanced computed tomography is an emerging diagnostic technique for osteoarthritis. However, the effects of increased water content, as well as decreased collagen and proteoglycan concentrations due to cartilage degeneration, on the diffusion of cationic and nonionic agents, are not fully understood. We hypothesize that for a cationic agent, these variations increase the diffusion rate while decreasing partition, whereas, for a nonionic agent, these changes increase both the rate of diffusion and partition. Thus, we examine the diffusion of cationic and nonionic contrast agents within degraded tissue in time- and depth-dependent manners. Osteochondral plugs (N = 15, d = 8 mm) were extracted from human cadaver knee joints, immersed in a mixture of cationic CA4+ and nonionic gadoteridol contrast agents, and imaged at multiple time-points, using the dual-contrast method. Water content, and collagen and proteoglycan concentrations were determined using lyophilization, infrared spectroscopy, and digital densitometry, respectively. Superficial to mid (0%-60% depth) cartilage CA4+ partitions correlated with water content (R < -0.521, P < .05), whereas in deeper (40%-100%) cartilage, CA4+ correlated only with proteoglycans (R > 0.671, P < .01). Gadoteridol partition correlated inversely with collagen concentration (0%-100%, R < -0.514, P < .05). Cartilage degeneration substantially increased the time for CA4+ compared with healthy tissue (248 ± 171 vs 175 ± 95 minute) to reach the bone-cartilage interface, whereas for gadoteridol the time (111 ± 63 vs 179 ± 163 minute) decreased. The work clarifies the diffusion mechanisms of two different contrast agents and presents depth and time-dependent effects resulting from articular cartilage constituents. The results will inform the development of new contrast agents and optimal timing between agent administration and joint imaging.
Collapse
|
52
|
Snijders TE, Schlösser TPC, van Stralen M, Castelein RM, Stevenson RP, Weinans H, de Gast A. The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific. Clin Orthop Relat Res 2021; 479:561-571. [PMID: 33009235 PMCID: PMC7899699 DOI: 10.1097/corr.0000000000001489] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 08/19/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Sagittal pelvic dynamics mainly consist of the pelvis rotating anteriorly or posteriorly while the hips flexes, and this affects the femoroacetabular or THA configuration. Thus far, it is unknown how the acetabular cup of the THA in the individual patient reorients with changing sagittal pelvic dynamics. QUESTIONS/PURPOSES The aim of this study was to validate a method that establishes the three-dimensional (3-D) acetabular cup orientation with changing sagittal pelvic dynamics and describe these changes during functional pelvic dynamics. METHODS A novel trigonometric mathematical model, which was incorporated into an easy-to-use tool, was tested. The model connected sagittal tilt, transverse version, and coronal inclination of the acetabular cup during sagittal pelvic tilt. Furthermore, the effect of sagittal pelvic tilt on the 3-D reorientation of acetabular cups was simulated for cups with different initial positions. Twelve pelvic CT images of patients who underwent THA were taken and rotated around the hip axis to different degrees of anterior and posterior sagittal pelvic tilt (± 30°) to simulate functional pelvic tilt in various body positions. For each simulated pelvic tilt, the transverse version and coronal inclination of the cup were manually measured and compared with those measured in a mathematical model in which the 3-D cup positions were calculated. Next, this model was applied to different acetabular cup positions to simulate the effect of sagittal pelvic dynamics on the 3-D orientation of the acetabular cup in the coronal and transverse plane. After pelvic tilt was applied, the intraclass correlation coefficients of 108 measured and calculated coronal and transverse cup orientation angles were 0.963 and 0.990, respectively, validating the clinical use of the mathematical model. RESULTS The changes in 3-D acetabular cup orientation by functional pelvic tilt differed substantially between cups with different initial positions; the change in transverse version was much more pronounced in cups with low coronal inclination (from 50° to -29°) during functional pelvic tilt than in cups with a normal coronal inclination (from 39° to -11°) or high coronal inclination (from 31° to 2°). However, changes in coronal inclination were more pronounced in acetabular cups with high transverse version. CONCLUSION Using a simple algorithm to determine the dynamic 3-D reorientation of the acetabular cup during functional sagittal pelvic tilt, we demonstrated that the 3-D effect of functional pelvic tilt is specific to the initial acetabular cup orientation and thus per THA patient. CLINICAL RELEVANCE Future studies concerning THA (in)stability should not only include the initial acetabular cup orientation, but also they need to incorporate the effect of sagittal pelvic dynamics on the individual 3-D acetabular cup orientation. Clinicians can also use the developed tool, www.3d-hip.com, to calculate the acetabular cup's orientation in other instances, such as for patients with spinopelvic imbalance.
Collapse
|
53
|
Khokhani P, Rahmani NR, Kok A, Öner FC, Alblas J, Weinans H, Kruyt MC, Croes M. Use of Therapeutic Pathogen Recognition Receptor Ligands for Osteo-Immunomodulation. MATERIALS 2021; 14:ma14051119. [PMID: 33673651 PMCID: PMC7957819 DOI: 10.3390/ma14051119] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 02/22/2021] [Indexed: 01/08/2023]
Abstract
Therapeutic pathogen recognition receptor (PRR) ligands are reaching clinical practice following their ability to skew the immune response in a specific direction. We investigated the effects of various therapeutic PRR ligands on bone cell differentiation and inflammation. Following stimulation, alkaline phosphatase (ALP) activity (Day 10), osteocalcin, osteonectin expression (Day 14), and calcium deposition (Day 21) were quantified in bone marrow-derived human mesenchymal stem cells (hMSCs). The osteoclastogenic response was determined by measuring tartrate-resistant acid phosphate (TRAP) activity in human monocytes. TNF-α, IL-6, IL-8, and IL-10 expressions were measured by enzyme-linked immunosorbent assay as an indicator of the ligands’ inflammatory properties. We found that nucleic acid-based ligands Poly(I:C) and CpG ODN C increased early ALP activity in hMSCs by 4-fold without affecting osteoclast formation. These ligands did not enhance expression of the other, late osteogenic markers. MPLA, Curdlan, and Pam3CSK4 did not affect osteogenic differentiation, but inhibited TRAP activity in monocytes, which was associated with increased expression of all measured cytokines. Nucleic acid-based ligands are identified as the most promising osteo-immunomodulators, as they favor early osteogenic differentiation without inducing an exaggerated immune-cell mediated response or interfering in osteoclastogenesis and thus can be potentially harnessed for multifunctional coatings for bone biomaterials.
Collapse
|
54
|
Gielis WP, Rayegan H, Arbabi V, Ahmadi Brooghani SY, Lindner C, Cootes TF, de Jong PA, Weinans H, Custers RJH. Predicting the mechanical hip-knee-ankle angle accurately from standard knee radiographs: a cross-validation experiment in 100 patients. Acta Orthop 2020; 91:732-737. [PMID: 32567436 PMCID: PMC8023880 DOI: 10.1080/17453674.2020.1779516] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Being able to predict the hip-knee-ankle angle (HKAA) from standard knee radiographs allows studies on malalignment in cohorts lacking full-limb radiography. We aimed to develop an automated image analysis pipeline to measure the femoro-tibial angle (FTA) from standard knee radiographs and test various FTA definitions to predict the HKAA. Patients and methods - We included 110 pairs of standard knee and full-limb radiographs. Automatic search algorithms found anatomic landmarks on standard knee radiographs. Based on these landmarks, the FTA was automatically calculated according to 9 different definitions (6 described in the literature and 3 newly developed). Pearson and intra-class correlation coefficient [ICC]) were determined between the FTA and HKAA as measured on full-limb radiographs. Subsequently, the top 4 FTA definitions were used to predict the HKAA in a 5-fold cross-validation setting. Results - Across all pairs of images, the Pearson correlations between FTA and HKAA ranged between 0.83 and 0.90. The ICC values from 0.83 to 0.90. In the cross-validation experiments to predict the HKAA, these values decreased only minimally. The mean absolute error for the best method to predict the HKAA from standard knee radiographs was 1.8° (SD 1.3). Interpretation - We showed that the HKAA can be automatically predicted from standard knee radiographs with fair accuracy and high correlation compared with the true HKAA. Therefore, this method enables research of the relationship between malalignment and knee pathology in large (epidemiological) studies lacking full-limb radiography.
Collapse
|
55
|
Bhattarai A, Pouran B, Mäkelä JTA, Shaikh R, Honkanen MKM, Prakash M, Kröger H, Grinstaff MW, Weinans H, Jurvelin JS, Töyräs J. Dual contrast in computed tomography allows earlier characterization of articular cartilage over single contrast. J Orthop Res 2020; 38:2230-2238. [PMID: 32525582 DOI: 10.1002/jor.24774] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 05/14/2020] [Accepted: 05/28/2020] [Indexed: 02/04/2023]
Abstract
Cationic computed tomography contrast agents are more sensitive for detecting cartilage degeneration than anionic or non-ionic agents. However, osteoarthritis-related loss of proteoglycans and increase in water content contrarily affect the diffusion of cationic contrast agents, limiting their sensitivity. The quantitative dual-energy computed tomography technique allows the simultaneous determination of the partitions of iodine-based cationic (CA4+) and gadolinium-based non-ionic (gadoteridol) agents in cartilage at diffusion equilibrium. Normalizing the cationic agent partition at diffusion equilibrium with that of the non-ionic agent improves diagnostic sensitivity. We hypothesize that this sensitivity improvement is also prominent during early diffusion time points and that the technique is applicable during contrast agent diffusion. To investigate the validity of this hypothesis, osteochondral plugs (d = 8 mm, N = 33), extracted from human cadaver (n = 4) knee joints, were immersed in a contrast agent bath (a mixture of CA4+ and gadoteridol) and imaged using the technique at multiple time points until diffusion equilibrium. Biomechanical testing and histological analysis were conducted for reference. Quantitative dual-energy computed tomography technique enabled earlier determination of cartilage proteoglycan content over single contrast. The correlation coefficient between human articular cartilage proteoglycan content and CA4+ partition increased with the contrast agent diffusion time. Gadoteridol normalized CA4+ partition correlated significantly (P < .05) with Mankin score at all time points and with proteoglycan content after 4 hours. The technique is applicable during diffusion, and normalization with gadoteridol partition improves the sensitivity of the CA4+ contrast agent.
Collapse
|
56
|
van Erp JHJ, Gielis WP, Arbabi V, de Gast A, Weinans H, Arbabi S, Öner FC, Castelein RM, Schlösser TPC. Unravelling the knee-hip-spine trilemma from the CHECK study. Bone Joint J 2020; 102-B:1261-1267. [PMID: 32862680 DOI: 10.1302/0301-620x.102b9.bjj-2019-1315.r2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aetiologies of common degenerative spine, hip, and knee pathologies are still not completely understood. Mechanical theories have suggested that those diseases are related to sagittal pelvic morphology and spinopelvic-femoral dynamics. The link between the most widely used parameter for sagittal pelvic morphology, pelvic incidence (PI), and the onset of degenerative lumbar, hip, and knee pathologies has not been studied in a large-scale setting. METHODS A total of 421 patients from the Cohort Hip and Cohort Knee (CHECK) database, a population-based observational cohort, with hip and knee complaints < 6 months, aged between 45 and 65 years old, and with lateral lumbar, hip, and knee radiographs available, were included. Sagittal spinopelvic parameters and pathologies (spondylolisthesis and degenerative disc disease (DDD)) were measured at eight-year follow-up and characteristics of hip and knee osteoarthritis (OA) at baseline and eight-year follow-up. Epidemiology of the degenerative disorders and clinical outcome scores (hip and knee pain and Western Ontario and McMaster Universities Osteoarthritis Index) were compared between low PI (< 50°), normal PI (50° to 60°), and high PI (> 60°) using generalized estimating equations. RESULTS Demographic details were not different between the different PI groups. L4 to L5 and L5 to S1 spondylolisthesis were more frequently present in subjects with high PI compared to low PI (L4 to L5, OR 3.717; p = 0.024 vs L5 to S1 OR 7.751; p = 0.001). L5 to S1 DDD occurred more in patients with low PI compared to high PI (OR 1.889; p = 0.010), whereas there were no differences in L4 to L5 DDD among individuals with a different PI. The incidence of hip OA was higher in participants with low PI compared to normal (OR 1.262; p = 0.414) or high PI (OR 1.337; p = 0.274), but not statistically different. The incidence of knee OA was higher in individuals with a high PI compared to low PI (OR 1.620; p = 0.034). CONCLUSION High PI is a risk factor for development of spondylolisthesis and knee OA. Low pelvic incidence is related to DDD, and may be linked to OA of the hip. Level of Evidence: 1b Cite this article: Bone Joint J 2020;102-B(9):1261-1267.
Collapse
|
57
|
Willemsen K, Doelman CJ, Sam ASY, Seevinck PR, Sakkers RJB, Weinans H, van Der Wal BCH. Long-term outcomes of the hip shelf arthroplasty in adolescents and adults with residual hip dysplasia: a systematic review. Acta Orthop 2020; 91:383-389. [PMID: 32237929 PMCID: PMC8023942 DOI: 10.1080/17453674.2020.1747210] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The shelf arthroplasty was the regular treatment for residual hip dysplasia before it was substituted by the peri-acetabular osteotomy. Yet, evidence regarding the survival of shelf arthroplasty surgery has never been systematically documented. Hence, we investigated the survival time of the shelf procedure until revision to THA in patients with primary hip dysplasia. Factors that influenced survival and complications were also examined, along with the accuracy of correcting radiographic parameters to characterize dysplasia.Material and methods - The inclusion criteria were studies of human adolescents and adults (> 16 years) with primary or congenital hip dysplasia who were treated with a shelf arthroplasty procedure. Data were extracted concerning patient characteristics, survival time, complications, operative techniques, and accuracy of correcting radiographic parameters.Results - Our inclusion criteria were applicable to 9 studies. The average postoperative Center-Edge Angle and Acetabular Head Index were mostly within target range, but large variations were common. Kaplan-Meier curves (endpoint: conversion to THA) varied between 37% at 20 years' follow-up and 72% at 35 years' follow-up. Clinical failures were commonly associated with pain and radiographic osteoarthritis. Only minor complications were reported with incidences between 17% and 32%.Interpretation - The shelf arthroplasty is capable of restoring normal radiographic hip parameters and is not associated with major complications. When carefully selected on minimal osteoarthritic changes, hip dysplasia patients with a closed triradiate cartilage may benefit from the shelf procedure with satisfactory survival rates. The importance of the shelf arthroplasty in relation to peri-acetabular osteotomies needs to be further (re)explored.
Collapse
|
58
|
van Dijk B, Lemans JVC, Hoogendoorn RM, Dadachova E, de Klerk JMH, Vogely HC, Weinans H, Lam MGEH, van der Wal BCH. Treating infections with ionizing radiation: a historical perspective and emerging techniques. Antimicrob Resist Infect Control 2020; 9:121. [PMID: 32736656 PMCID: PMC7393726 DOI: 10.1186/s13756-020-00775-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 07/09/2020] [Indexed: 01/09/2023] Open
Abstract
Background Widespread use and misuse of antibiotics have led to a dramatic increase in the emergence of antibiotic resistant bacteria, while the discovery and development of new antibiotics is declining. This has made certain implant-associated infections such as periprosthetic joint infections, where a biofilm is formed, very difficult to treat. Alternative treatment modalities are needed to treat these types of infections in the future. One candidate that has been used extensively in the past, is the use of ionizing radiation. This review aims to provide a historical overview and future perspective of radiation therapy in infectious diseases with a focus on orthopedic infections. Methods A systematic search strategy was designed to select studies that used radiation as treatment for bacterial or fungal infections. A total of 216 potentially relevant full-text publications were independently reviewed, of which 182 focused on external radiation and 34 on internal radiation. Due to the large number of studies, several topics were chosen. The main advantages, disadvantages, limitations, and implications of radiation treatment for infections were discussed. Results In the pre-antibiotic era, high mortality rates were seen in different infections such as pneumonia, gas gangrene and otitis media. In some cases, external radiation therapy decreased the mortality significantly but long-term follow-up of the patients was often not performed so long term radiation effects, as well as potential increased risk of malignancies could not be investigated. Internal radiation using alpha and beta emitting radionuclides show great promise in treating fungal and bacterial infections when combined with selective targeting through antibodies, thus minimizing possible collateral damage to healthy tissue. Conclusion The novel prospects of radiation treatment strategies against planktonic and biofilm-related microbial infections seem feasible and are worth investigating further. However, potential risks involving radiation treatment must be considered in each individual patient.
Collapse
|
59
|
van Hengel I, Gelderman F, Athanasiadis S, Minneboo M, Weinans H, Fluit A, van der Eerden B, Fratila-Apachitei L, Apachitei I, Zadpoor A. Functionality-packed additively manufactured porous titanium implants. Mater Today Bio 2020; 7:100060. [PMID: 32577614 PMCID: PMC7305382 DOI: 10.1016/j.mtbio.2020.100060] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/26/2020] [Accepted: 05/28/2020] [Indexed: 12/30/2022] Open
Abstract
The holy grail of orthopedic implant design is to ward off both aseptic and septic loosening for long enough that the implant outlives the patient. Questing this holy grail is feasible only if orthopedic biomaterials possess a long list of functionalities that enable them to discharge the onerous task of permanently replacing the native bone tissue. Here, we present a rationally designed and additive manufacturing (AM) topologically ordered porous metallic biomaterial that is made from Ti-6Al-4V using selective laser melting and packs most (if not all) of the required functionalities into a single implant. In addition to presenting a fully interconnected porous structure and form-freedom that enables realization of patient-specific implants, the biomaterials developed here were biofunctionalized using plasma electrolytic oxidation to locally release both osteogenic (i.e. strontium) and antibacterial (i.e. silver ions) agents. The same single-step biofunctionalization process also incorporated hydroxyapatite into the surface of the implants. Our measurements verified the continued release of both types of active agents up to 28 days. Assessment of the antibacterial activity in vitro and in an ex vivo murine model demonstrated extraordinarily high levels of bactericidal effects against a highly virulent and multidrug-resistant Staphylococcus aureus strain (i.e. USA300) with total eradication of both planktonic and adherent bacteria. This strong antibacterial behavior was combined with a significantly enhanced osteogenic behavior, as evidenced by significantly higher levels of alkaline phosphatase (ALP) activity compared with non-biofunctionalized implants. Finally, we discovered synergistic antibacterial behavior between strontium and silver ions, meaning that 4-32 folds lower concentrations of silver ions were required to achieve growth inhibition and total killing of bacteria. The functionality-packed biomaterial presented here demonstrates a unique combination of functionalities that make it an advanced prototype of future orthopedic biomaterials where implants will outlive patients.
Collapse
|
60
|
van Dijk B, Allen KJH, Helal M, Vogely HC, Lam MGEH, de Klerk JMH, Weinans H, van der Wal BCH, Dadachova E. Radioimmunotherapy of methicillin-resistant Staphylococcus aureus in planktonic state and biofilms. PLoS One 2020; 15:e0233086. [PMID: 32407350 PMCID: PMC7224548 DOI: 10.1371/journal.pone.0233086] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 04/28/2020] [Indexed: 12/17/2022] Open
Abstract
Background Implant associated infections such as periprosthetic joint infections are difficult to treat as the bacteria form a biofilm on the prosthetic material. This biofilm complicates surgical and antibiotic treatment. With rising antibiotic resistance, alternative treatment options are needed to treat these infections in the future. The aim of this article is to provide proof-of-principle data required for further development of radioimmunotherapy for non-invasive treatment of implant associated infections. Methods Planktonic cells and biofilms of Methicillin-resistant staphylococcus aureus are grown and treated with radioimmunotherapy. The monoclonal antibodies used, target wall teichoic acids that are cell and biofilm specific. Three different radionuclides in different doses were used. Viability and metabolic activity of the bacterial cells and biofilms were measured by CFU dilution and XTT reduction. Results Alpha-RIT with Bismuth-213 showed significant and dose dependent killing in both planktonic MRSA and biofilm. When planktonic bacteria were treated with 370 kBq of 213Bi-RIT 99% of the bacteria were killed. Complete killing of the bacteria in the biofilm was seen at 185 kBq. Beta-RIT with Lutetium-177 and Actinium-225 showed little to no significant killing. Conclusion Our results demonstrate the ability of specific antibodies loaded with an alpha-emitter Bismuth-213 to selectively kill staphylococcus aureus cells in vitro in both planktonic and biofilm state. RIT could therefore be a potentially alternative treatment modality against planktonic and biofilm-related microbial infections.
Collapse
|
61
|
Warmink K, Kozijn AE, Bobeldijk I, Stoop R, Weinans H, Korthagen NM. High-fat feeding primes the mouse knee joint to develop osteoarthritis and pathologic infrapatellar fat pad changes after surgically induced injury. Osteoarthritis Cartilage 2020; 28:593-602. [PMID: 32222415 DOI: 10.1016/j.joca.2020.03.008] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 03/10/2020] [Accepted: 03/13/2020] [Indexed: 02/07/2023]
Abstract
OBJECTIVE Obesity is one of the greatest risk factors for osteoarthritis (OA) and evidence is accumulating that inflammatory mediators and innate immunity play an important role. The infrapatellar fat pad (IPFP) could be a potential local source of inflammatory mediators in the knee. Here, we combine surgical joint damage with high-fat feeding in mice to investigate inflammatory responses in the IPFP during OA development. DESIGN Mice (n = 30) received either a low-fat diet (LFD), high-fat diet (HFD) for 18 weeks or switched diets (LFD > HFD) after 10 weeks. OA was induced by surgical destabilization of the medial meniscus (DMM), contralateral knees served as sham controls. An additional HFD-only group (n = 15) received no DMM. RESULTS The most pronounced inflammation, characterized by macrophage crown-like structures (CLS), was found in HFD + DMM mice, CLS increased compared to HFD only (mean difference = 7.26, 95%CI [1.52-13.0]) and LFD + DMM (mean difference = 6.35, 95%CI [0.53-12.18). The M1 macrophage marker iNOS increased by DMM (ratio = 2.48, 95%CI [1.37-4.50]), while no change in M2 macrophage marker CD206 was observed. Fibrosis was minimal by HFD alone, but in combination with DMM it increased with 23.45% (95%CI [13.67-33.24]). CONCLUSIONS These findings indicate that a high-fat diet alone does not trigger inflammation or fibrosis in the infrapatellar fat pad, but in combination with an extra damage trigger, like DMM, induces inflammation and fibrosis in the infrapatellar fat pad. These data suggest that HFD provides a priming effect on the infrapatellar fat pad and that combined actions bring the joint in a metabolic state of progressive OA.
Collapse
|
62
|
Koolen M, Amin Yavari S, Lietaert K, Wauthle R, Zadpoor AA, Weinans H. Bone Regeneration in Critical-Sized Bone Defects Treated with Additively Manufactured Porous Metallic Biomaterials: The Effects of Inelastic Mechanical Properties. MATERIALS 2020; 13:ma13081992. [PMID: 32344664 PMCID: PMC7215733 DOI: 10.3390/ma13081992] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 04/15/2020] [Accepted: 04/21/2020] [Indexed: 02/05/2023]
Abstract
Additively manufactured (AM) porous metallic biomaterials, in general, and AM porous titanium, in particular, have recently emerged as promising candidates for bone substitution. The porous design of such materials allows for mimicking the elastic mechanical properties of native bone tissue and showed to be effective in improving bone regeneration. It is, however, not clear what role the other mechanical properties of the bulk material such as ductility play in the performance of such biomaterials. In this study, we compared the bone tissue regeneration performance of AM porous biomaterials made from the commonly used titanium alloy Ti6Al4V-ELI with that of commercially pure titanium (CP-Ti). CP-Ti was selected because of its high ductility as compared to Ti6Al4V-ELI. Critical-sized (6 mm diameter) femoral defects in rats were treated with implants made from both Ti6Al4V-ELI and CP-Ti. Bone regeneration was assessed up to 11 weeks using micro-CT scanning. The regenerated bone volume was assessed ex vivo followed by histology and biomechanical testing to assess osseointegration of the implants. The bony defects treated with AM CP-Ti implants generally showed higher volumes of regenerated bone as compared to those treated with AM Ti6Al4V-ELI. The torsional strength of the two titanium groups were similar however, and both considerably lower than those measured for intact bony tissue. These findings show the importance of material type and ductility of the bulk material in the ability for bone tissue regeneration of AM porous biomaterials.
Collapse
|
63
|
Florkow MC, Zijlstra F, Willemsen K, Maspero M, van den Berg CAT, Kerkmeijer LGW, Castelein RM, Weinans H, Viergever MA, van Stralen M, Seevinck PR. Deep learning-based MR-to-CT synthesis: The influence of varying gradient echo-based MR images as input channels. Magn Reson Med 2020; 83:1429-1441. [PMID: 31593328 PMCID: PMC6972695 DOI: 10.1002/mrm.28008] [Citation(s) in RCA: 63] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Revised: 08/30/2019] [Accepted: 08/31/2019] [Indexed: 01/15/2023]
Abstract
PURPOSE To study the influence of gradient echo-based contrasts as input channels to a 3D patch-based neural network trained for synthetic CT (sCT) generation in canine and human populations. METHODS Magnetic resonance images and CT scans of human and canine pelvic regions were acquired and paired using nonrigid registration. Magnitude MR images and Dixon reconstructed water, fat, in-phase and opposed-phase images were obtained from a single T1 -weighted multi-echo gradient-echo acquisition. From this set, 6 input configurations were defined, each containing 1 to 4 MR images regarded as input channels. For each configuration, a UNet-derived deep learning model was trained for synthetic CT generation. Reconstructed Hounsfield unit maps were evaluated with peak SNR, mean absolute error, and mean error. Dice similarity coefficient and surface distance maps assessed the geometric fidelity of bones. Repeatability was estimated by replicating the training up to 10 times. RESULTS Seventeen canines and 23 human subjects were included in the study. Performance and repeatability of single-channel models were dependent on the TE-related water-fat interference with variations of up to 17% in mean absolute error, and variations of up to 28% specifically in bones. Repeatability, Dice similarity coefficient, and mean absolute error were statistically significantly better in multichannel models with mean absolute error ranging from 33 to 40 Hounsfield units in humans and from 35 to 47 Hounsfield units in canines. CONCLUSION Significant differences in performance and robustness of deep learning models for synthetic CT generation were observed depending on the input. In-phase images outperformed opposed-phase images, and Dixon reconstructed multichannel inputs outperformed single-channel inputs.
Collapse
|
64
|
Gielis WP, Weinans H, Welsing PMJ, van Spil WE, Agricola R, Cootes TF, de Jong PA, Lindner C. An automated workflow based on hip shape improves personalized risk prediction for hip osteoarthritis in the CHECK study. Osteoarthritis Cartilage 2020; 28:62-70. [PMID: 31604136 DOI: 10.1016/j.joca.2019.09.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 09/07/2019] [Accepted: 09/22/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To design an automated workflow for hip radiographs focused on joint shape and tests its prognostic value for future hip osteoarthritis. DESIGN We used baseline and 8-year follow-up data from 1,002 participants of the CHECK-study. The primary outcome was definite radiographic hip osteoarthritis (rHOA) (Kellgren-Lawrence grade ≥2 or joint replacement) at 8-year follow-up. We designed a method to automatically segment the hip joint from radiographs. Subsequently, we applied machine learning algorithms (elastic net with automated parameter optimization) to provide the Shape-Score, a single value describing the risk for future rHOA based solely on joint shape. We built and internally validated prediction models using baseline demographics, physical examination, and radiologists scores and tested the added prognostic value of the Shape-Score using Area-Under-the-Curve (AUC). Missing data was imputed by multiple imputation by chained equations. Only hips with pain in the corresponding leg were included. RESULTS 84% were female, mean age was 56 (±5.1) years, mean BMI 26.3 (±4.2). Of 1,044 hips with pain at baseline and complete follow-up, 143 showed radiographic osteoarthritis and 42 were replaced. 91.5% of the hips had follow-up data available. The Shape-Score was a significant predictor of rHOA (odds ratio per decimal increase 5.21, 95%-CI (3.74-7.24)). The prediction model using demographics, physical examination, and radiologists scores demonstrated an AUC of 0.795, 95%-CI (0.757-0.834). After addition of the Shape-Score the AUC rose to 0.864, 95%-CI (0.833-0.895). CONCLUSIONS Our Shape-Score, automatically derived from radiographs using a novel machine learning workflow, may strongly improve risk prediction in hip osteoarthritis.
Collapse
|
65
|
Li Y, Jahr H, Pavanram P, Bobbert F, Paggi U, Zhang XY, Pouran B, Leeflang M, Weinans H, Zhou J, Zadpoor A. Corrigendum to "Additively manufactured functionally graded biodegradable porous iron" [Acta Biomaterialia 96 (2019) 646-661]. Acta Biomater 2020; 101:646. [PMID: 31786087 DOI: 10.1016/j.actbio.2019.11.040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
66
|
Rudnik-Jansen I, Tellegen AR, Pouran B, Schrijver K, Meij BP, Emans PJ, de Gendt E, Thomas RE, Kik MJL, de Visser HM, Weinans H, Egas A, van Maarseveen E, Woike N, Mihov G, Thies J, Tryfonidou MA, Creemers LB. Local controlled release of corticosteroids extends surgically induced joint instability by inhibiting tissue healing. Br J Pharmacol 2019; 176:4050-4064. [PMID: 31378925 PMCID: PMC6811746 DOI: 10.1111/bph.14817] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 05/28/2019] [Accepted: 07/11/2019] [Indexed: 12/11/2022] Open
Abstract
Background and Purpose Corticosteroids are intra‐articularly injected to relieve pain in joints with osteoarthritis (OA) or acute tissue damage such as ligament or tendon tears, despite its unverified contraindication in unstable joints. Biomaterial‐based sustained delivery may prolong reduction of inflammatory pain, while avoiding harmful peak drug concentrations. Experimental Approach The applicability of prolonged corticosteroid exposure was examined in a rat model of anterior cruciate ligament and medial meniscus transection (ACLT + pMMx) with ensuing degenerative changes. Key Results Intra‐articular injection of a bolus of the corticosteroid triamcinolone acetonide (TAA) resulted in enhanced joint instability in 50% of the joints, but neither instability‐induced OA cartilage degeneration, synovitis, nor the OA‐related bone phenotype was affected. However, biomaterial microsphere‐based extended TAA release enhanced instability in 94% of the animals and induced dystrophic calcification and exacerbation of cartilage degeneration. In healthy joints, injection with TAA releasing microspheres had no effect at all. In vitro, TAA inhibited cell migration out of joint tissue explants, suggesting inhibited tissue healing in vivo as mechanisms for enhanced instability and subsequent cartilage degeneration. Conclusions and Implications We conclude that short‐term TAA exposure has minor effects on surgically induced unstable joints, but its extended presence is detrimental by extending instability and associated joint degeneration through compromised healing. This supports a contraindication of prolonged corticosteroid exposure in tissue damage‐associated joint instability, but not of brief exposure.
Collapse
|
67
|
Mancini IAD, Rieppo L, Pouran B, Afara IO, Braganca FMS, van Rijen MHP, Kik M, Weinans H, Toyras J, van Weeren PR, Malda J. Effects of body mass on microstructural features of the osteochondral unit: A comparative analysis of 37 mammalian species. Bone 2019; 127:664-673. [PMID: 31279095 DOI: 10.1016/j.bone.2019.07.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 06/28/2019] [Accepted: 07/02/2019] [Indexed: 01/26/2023]
Abstract
Since Galileo's days the effect of size on the anatomical characteristics of the structural elements of the body has been a subject of interest. However, the effects of scaling at tissue level have received little interest and virtually no data exist on the subject with respect to the osteochondral unit in the joint, despite this being one of the most lesion-prone and clinically relevant parts of the musculoskeletal system. Imaging techniques, including Fourier transform infrared imaging, polarized light microscopy and micro computed tomography, were combined to study the response to increasing body mass of the osteochondral unit. We analyzed the effect of scaling on structural characteristics of articular cartilage, subchondral plate and the supporting trabecular bone, across a wide range of mammals at microscopic level. We demonstrated that, while total cartilage thickness scales to body mass in a negative allometric fashion, thickness of different cartilage layers did not. Cartilage tissue layers were found to adapt to increasing loads principally in the deep zone with the superficial layers becoming relatively thinner. Subchondral plate thickness was found to have no correlation to body mass, nor did bone volume fraction. The underlying trabecular bone was found to have thicker trabeculae (r=0.75, p<0.001), as expected since this structure carries most loads and plays a role in force mitigation. The results of this study suggest that the osteochondral tissue structure has remained remarkably preserved across mammalian species during evolution, and that in particular, the trabecular bone carries the adaptation to the increasing body mass.
Collapse
|
68
|
Koolen M, Longoni A, van der Stok J, Van der Jagt O, Gawlitta D, Weinans H. Complete regeneration of large bone defects in rats with commercially available fibrin loaded with BMP-2. Eur Cell Mater 2019; 38:94-105. [PMID: 31529455 DOI: 10.22203/ecm.v038a08] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
This study aimed at investigating in vitro and in vivo the efficiency of commercially available fibrin as a carrier for controlled and sustained bone morphogenetic protein-2 (BMP-2) release to induce bone formation and reduce the side effects of its use. In vitro release and activity of low-dose recombinant human BMP-2 (rhBMP-2) (37.5 µg/mL) embedded in commercially available fibrin were evaluated and, subsequently, critical-size femur defects in rats were grafted to study bone regeneration and vascularisation by micro-computed tomography (µCT) and histology. In vitro experiments showed a sustained BMP-2 release with a high BMP activity remaining after 28 d. In vivo, fibrin loaded with BMP-2 showed an extremely fast bone healing, with a large amount of new bone formation throughout the entire defect in the first 4 weeks and complete cortical repair and fusion after 8 weeks, with no ectopic bone formation. In contrast, the control fibrin group did not fuse after 12 weeks. Vascularisation was similar in both groups at 4 and 12 weeks after implantation. In conclusion, commercially available fibrin is a very efficient carrier for rhBMP-2 to graft critical-size cortical bone defects and might be a more optimal delivery vehicle for BMP-2-induced bone regeneration than currently available collagen sponges.
Collapse
|
69
|
Li Y, Jahr H, Pavanram P, Bobbert FSL, Paggi U, Zhang XY, Pouran B, Leeflang MA, Weinans H, Zhou J, Zadpoor AA. Additively manufactured functionally graded biodegradable porous iron. Acta Biomater 2019; 96:646-661. [PMID: 31302295 DOI: 10.1016/j.actbio.2019.07.013] [Citation(s) in RCA: 79] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 07/03/2019] [Accepted: 07/09/2019] [Indexed: 11/28/2022]
Abstract
Additively manufactured (AM) functionally graded porous metallic biomaterials offer unique opportunities to satisfy the contradictory design requirements of an ideal bone substitute. However, no functionally graded porous structures have ever been 3D-printed from biodegradable metals, even though biodegradability is crucial both for full tissue regeneration and for the prevention of implant-associated infections in the long term. Here, we present the first ever report on AM functionally graded biodegradable porous metallic biomaterials. We made use of a diamond unit cell for the topological design of four different types of porous structures including two functionally graded structures and two reference uniform structures. Specimens were then fabricated from pure iron powder using selective laser melting (SLM), followed by experimental and computational analyses of their permeability, dynamic biodegradation behavior, mechanical properties, and cytocompatibility. It was found that the topological design with functional gradients controlled the fluid flow, mass transport properties and biodegradation behavior of the AM porous iron specimens, as up to 4-fold variations in permeability and up to 3-fold variations in biodegradation rate were observed for the different experimental groups. After 4 weeks of in vitro biodegradation, the AM porous scaffolds lost 5-16% of their weight. This falls into the desired range of biodegradation rates for bone substitution and confirms our hypothesis that topological design could indeed accelerate the biodegradation of otherwise slowly degrading metals, like iron. Even after 4 weeks of biodegradation, the mechanical properties of the specimens (i.e., E = 0.5-2.1 GPa, σy = 8-48 MPa) remained within the range of the values reported for trabecular bone. Design-dependent cell viability did not differ from gold standard controls for up to 48 h. This study clearly shows the great potential of AM functionally graded porous iron as a bone substituting material. Moreover, we demonstrate that complex topological design permits the control of mechanical properties, degradation behavior of AM porous metallic biomaterials. STATEMENT OF SIGNIFICANCE: No functionally graded porous structures have ever been 3D-printed from biodegradable metals, even though biodegradability is crucial both for full tissue regeneration and for the prevention of implant-associated infections in the long term. Here, we present the first report on 3D-printed functionally graded biodegradable porous metallic biomaterials. Our results suggest that topological design in general, and functional gradients in particular can be used as an important tool for adjusting the biodegradation behavior of AM porous metallic biomaterials. The biodegradation rate and mass transport properties of AM porous iron can be increased while maintaining the bone-mimicking mechanical properties of these biomaterials. The observations reported here underline the importance of proper topological design in the development of AM porous biodegradable metals.
Collapse
|
70
|
Willemsen K, Nizak R, Noordmans HJ, Castelein RM, Weinans H, Kruyt MC. Challenges in the design and regulatory approval of 3D-printed surgical implants: a two-case series. LANCET DIGITAL HEALTH 2019; 1:e163-e171. [PMID: 33323186 DOI: 10.1016/s2589-7500(19)30067-6] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 06/10/2019] [Accepted: 06/11/2019] [Indexed: 01/01/2023]
Abstract
BACKGROUND Additive manufacturing or three-dimensional (3D) printing of metal implants can provide novel solutions for difficult-to-treat conditions, yet legislation concerning patient-specific implants complicates the implementation of these techniques in daily practice. In this Article, we share our acquired knowledge of the logistical and legal challenges associated with the use of patient-specific 3D-printed implants to treat spinal instabilities. METHODS Two patients with semiurgent cases of spinal instability presented to our hospital in the Netherlands. In case 1, severe kyphotic deformity of the thoracic spine due to neurofibromatosis type 1 had led to incomplete paralysis, and a strong metallic strut extending from C6 to T11 was deemed necessary to provide long-term anterior support. In case 2, the patient presented with progressive paralysis caused by cervicothoracic dissociation due to vanishing bone disease. As the C5-T1 vertebral bodies had mostly vanished, an implant spanning the anterior spine from C4 to T2 was required. Because of the complex and challenging nature of both cases, conventional approaches were deemed inadequate; instead, patient-specific implants were designed with use of CT scans and computer-aided design software, and 3D printed in titanium with direct metal printing. For each implant, to ensure patient safety, a comprehensive technical file (describing the clinical substantiation, technical and design considerations, risk analysis, manufacturing process, and labelling) was produced in collaboration with a university department certified for the development and manufacturing of medical devices. Because the implants were categorised as custom-made or personalised devices under the EU Medical Device Regulation, the usual procedures for review and approval of medical devices by a notified body were not required. Finite-element analyses, compression strength tests, and cadaveric experiments were also done to ensure the devices were safe to use. FINDINGS The planning, design, production, and insertion of the 3D-printed personalised implant took around 6 months in the first patient, but, given the experience from the first case, only took around 6 weeks in the second patient. In both patients, the surgeries went as planned and good positioning of each implant was confirmed. Both patients were discharged home within 1 week after the surgery. In the first patient, a fatigue fracture occured in one of the conventional posterior fusion rods after 10 months, which we repaired, without any deformation of the spine or signs of failure of the personalised implant observed. No other adverse events occurred up to 25 months of follow-up in case 1 and 6 months of follow-up in case 2. INTERPRETATION Patient-specific treatment approaches incorporating 3D-printed implants can be helpful in carefully selected cases when conventional methods are not an option. Comprehensive and efficient interactions between medical engineers and physicians are essential to establish well designed frameworks to navigate the logistical and regulatory aspects of technology development to ensure the safety and legal validity of patient-specific treatments. The framework described here could encourage physicians to treat (once untreatable) patients with novel personalised techniques. FUNDING Interreg VA Flanders-The Netherlands programme, Applied and Engineering Sciences research programme, the Netherlands Organisation for Scientific Research, and the Dutch Arthritis Foundation VIDEO ABSTRACT.
Collapse
|
71
|
Willemsen K, Berendes TD, Geurkink T, Bleys RL, Leeflang MA, Weinans H, Castelein RM, Nelissen RG, van der Wal BC. A Novel Treatment for Anterior Shoulder Instability: A Biomechanical Comparison Between a Patient-Specific Implant and the Latarjet Procedure. J Bone Joint Surg Am 2019; 101:e68. [PMID: 31318812 PMCID: PMC6641476 DOI: 10.2106/jbjs.18.00892] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Anterior glenohumeral instability with >20% glenoid bone loss is a disorder that can be treated with the Latarjet stabilizing procedure; however, complications are common. The purposes of this study were to (1) evaluate the effect of an anatomic-specific titanium implant produced by 3-dimensional (3D) printing as a treatment option for recurrent shoulder instability with substantial glenoid bone loss and (2) compare the use of that implant with the Latarjet procedure. METHODS Ten fresh-frozen cadaveric shoulders (mean age at the time of death, 78 years) were tested in a biomechanical setup with the humerus in 30° of abduction and in neutral rotation. The shoulders were tested under 5 different conditions: (1) normal situation, (2) creation of an anterior glenoid defect, (3) implantation of an anatomic-specific titanium implant produced by 3D printing, and the Latarjet procedure (4) with and (5) without 10 N of load attached to the conjoined tendon. In each condition, the humerus was translated 10 mm anteriorly relative to the glenoid, and the maximum peak translational force that was necessary for this translation was measured. RESULTS After creation of the glenoid defect, the mean translational peak force decreased by 30% ± 6% compared with that for the normal shoulder. After restoration of the original glenoid anatomy, the translational force needed to dislocate the humeral head from the glenoid significantly increased compared with that in the defect condition-to 119% ± 16% of normal (p < 0.01) with the 3D-printed anatomic-specific implant and to 121% ± 48% of normal (p < 0.01) following the Latarjet procedure. No significant differences in mean translational force were found between the anatomic-specific implant and the Latarjet procedure (p = 0.72). CONCLUSIONS The mean translational peak force needed to dislocate the humerus 10 mm anteriorly on the glenoid was higher after glenoid restoration with the 3D-printed anatomic-specific implant compared with when the glenoid had a 20% surface defect but also compared with when the glenoid was intact. No differences in mean translational peak force were found between the 3D-printed anatomic-specific glenoid implant and the Latarjet procedure, although there was less variability in the 3D-implant condition. CLINICAL RELEVANCE Novel 3D-printing technology could provide a reliable patient-specific alternative to solve problems related to traditional treatment methods for shoulder instability.
Collapse
|
72
|
de Visser HM, Sanchez C, Mastbergen SC, Lafeber FPJG, Henrotin YE, Weinans H. Fib3-3 as a Biomarker for Osteoarthritis in a Rat Model with Metabolic Dysregulation. Cartilage 2019; 10:329-334. [PMID: 29366335 PMCID: PMC6585292 DOI: 10.1177/1947603518754629] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
OBJECTIVE Fibulin-3 is a glycoprotein highly expressed in osteoarthritic cartilage and inhibits angiogenesis and chondrocyte differentiation. Recent studies have indicated that fibulin-3 has potential value as a biomarker in osteoarthritis. The aim of the present study is to examine the role of 3 fibulin-3 peptides (Fib3-1, Fib3-2, and Fib3-3) and a type II collagen degradation product in a rat osteoarthritis model with systemic metabolic alterations combined with local cartilage damage. DESIGN Forty, 12-week-old male, Wistar rats were randomly divided over 2 groups: a standard or a high-fat diet inducing metabolic dysregulation. After 12 weeks, articular cartilage damage was induced on the femoral condyles (groove model), in 1 knee joint in 14 rats of each diet group. At endpoint, blood was collected and serum was isolated. Enzyme-linked immunosorbent assay on all selected fibulin-3 fragments was performed from serum samples in addition to immunohistochemical analysis for Fib3-3. RESULTS Serum concentrations of Fib3-3 were increased by 29.9%, when cartilage damage was induced in addition to a high-fat diet. Fib3-3 was also associated with an increased histological total joint degeneration (r = 0.435) and cartilage degeneration (r = 0.435). Immunostainings demonstrated increased Fib3-3 in the superficial cartilage of animals with high-fat diet and/or cartilage damage. CONCLUSIONS In the rat groove model combined with high-fat diet-induced metabolic dysregulation an increased Fib3-3 concentration was observed systemically, which is associated with local joint degeneration. This suggests that systemic Fib3-3 concentrations can indicate the status of joint degeneration and function as a biomarker in osteoarthritis.
Collapse
|
73
|
Hirvasniemi J, Gielis WP, Arbabi S, Agricola R, van Spil WE, Arbabi V, Weinans H. Bone texture analysis for prediction of incident radiographic hip osteoarthritis using machine learning: data from the Cohort Hip and Cohort Knee (CHECK) study. Osteoarthritis Cartilage 2019; 27:906-914. [PMID: 30825609 DOI: 10.1016/j.joca.2019.02.796] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 01/27/2019] [Accepted: 02/10/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To assess the ability of radiography-based bone texture variables in proximal femur and acetabulum to predict incident radiographic hip osteoarthritis (rHOA) over a 10 years period. DESIGN Pelvic radiographs from CHECK at baseline (987 hips) were analyzed for bone texture using fractal signature analysis (FSA) in proximal femur and acetabulum. Elastic net (machine learning) was used to predict the incidence of rHOA (including Kellgren-Lawrence grade (KL) ≥ 2 or total hip replacement (THR)), joint space narrowing score (JSN, range 0-3), and osteophyte score (OST, range 0-3) after 10 years. Performance of prediction models was assessed using the area under the receiver operating characteristic curve (ROC AUC). RESULTS Of the 987 hips without rHOA at baseline, 435 (44%) had rHOA at 10-year follow-up. Of the 667 hips with JSN grade 0 at baseline, 471 (71%) had JSN grade ≥ 1 at 10-year follow-up. Of the 613 hips with OST grade 0 at baseline, 526 (86%) had OST grade ≥ 1 at 10-year follow-up. AUCs for the models including age, gender, and body mass index (BMI) to predict incident rHOA, JSN, and OST were 0.59, 0.54, and 0.51, respectively. The inclusion of bone texture variables in the models improved the prediction of incident rHOA (ROC AUC 0.68 and 0.71 when baseline KL was also included in the model) and JSN (ROC AUC 0.62), but not incident OST (ROC AUC 0.52). CONCLUSION Bone texture analysis provides additional information for predicting incident rHOA or THR over 10 years.
Collapse
|
74
|
Visser J, Melchels FPW, Weinans H, Kruyt MC, Malda J. [Applications of 3D printing in medicine; 5 years later]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2019; 163:D3683. [PMID: 31166096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
5 years ago, we described the emergence of 3D printing in medicine. It was about 3D printing of anatomical structures, patient-specific drilling guides, cutting templates and implants and printing of living cells, growth factors and biomaterials ('bioprinting'). Surgeons are increasingly making use of 3D printing possibilities in preparation of surgeries on patients with complicated anatomies. Using tangible 3D models, it is easier for surgeons to prepare for surgeries and discussions with patients. They can also use 3D models as a tool to help with the training of young surgeons. Permanent titanium implants are increasingly being printed. Bioprinting is still in its infancy and there are no direct clinical applications yet. As we already predicted 5 years ago, many hurdles still have to be taken before broad clinical application of bioprinted products will become a reality.
Collapse
|
75
|
Croes M, Kruyt MC, Boot W, Pouran B, Braham MV, Pakpahan SA, Weinans H, Vogely HC, Fluit AC, Dhert WJ, Alblas J, Öner FC. The role of bacterial stimuli in inflammation-driven bone formation. Eur Cell Mater 2019; 37:402-419. [PMID: 31094449 DOI: 10.22203/ecm.v037a24] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Immune cells and their soluble factors regulate skeletal cells during normal bone regeneration and pathological bone formation. Bacterial infections can trigger immune responses that activate pro-osteogenic pathways, but these are usually overshadowed by osteolysis and concerns of systemic inflammation. The aim of this study was to determine whether the transient local inflammatory reaction to non-viable bacterial immune agonists could lead to favourable new bone formation. In a series of rabbit studies, as proof-of-concept, how tibial intramedullary injection of viable or killed bacterial species affected bone remodelling and new bone formation was determined. Application of killed bacteria led to considerable new bone formation after 4 weeks, without the prolonged systemic inflammation and exaggerated bone lysis seen with active infection. The osteo-immunomodulatory effects of various species of killed bacteria and the dose response relationship were subsequently screened in ectopically-implanted ceramic scaffolds. Histomorphometry after 8 weeks showed that a relatively low dose of killed bacteria enhanced ectopic bone induction. Moreover, lipoteichoic acid - the bacterial cell-wall derived toll-like-receptor (TLR)-2 activator - was identified as an osteo-stimulatory factor. Collectively, the data indicated that bacterial stimuli could be harnessed to stimulate osteogenesis, which occurs through a synergy with osteoinductive signals. This finding holds promise for the use of non-viable bacteria, bacterial antigens, or their simplified analogues as immuno-modulatory bone regenerating tools in bone biomaterials.
Collapse
|
76
|
Tan Timur U, Caron M, van den Akker G, van der Windt A, Visser J, van Rhijn L, Weinans H, Welting T, Emans P, Jahr H. Increased TGF-β and BMP Levels and Improved Chondrocyte-Specific Marker Expression In Vitro under Cartilage-Specific Physiological Osmolarity. Int J Mol Sci 2019; 20:ijms20040795. [PMID: 30781744 PMCID: PMC6412363 DOI: 10.3390/ijms20040795] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Revised: 01/31/2019] [Accepted: 02/07/2019] [Indexed: 11/16/2022] Open
Abstract
During standard expansion culture (i.e., plasma osmolarity, 280 mOsm) human articular chondrocytes dedifferentiate, making them inappropriate for autologous chondrocyte implantation to treat cartilage defects. Increasing the osmolarity of culture media to physiological osmolarity levels of cartilage (i.e., 380 mOsm), increases collagen type II (COL2A1) expression of human articular chondrocytes in vitro, but the underlying molecular mechanism is not fully understood. We hypothesized that TGF-β superfamily signaling may drive expression of COL2A1 under physiological osmolarity culture conditions. Human articular chondrocytes were cultured in cytokine-free medium of 280 or 380 mOsm with or without siRNA mediated TGF-β2 knockdown (RNAi). Expression of TGF-β isoforms, and collagen type II was evaluated by RT-qPCR and immunoblotting. TGF-β2 protein secretion was evaluated using ELISA and TGF-β bioactivity was determined using an established reporter assay. Involvement of BMP signaling was investigated by culturing human articular chondrocytes in the presence or absence of BMP inhibitor dorsomorphin and BMP bioactivity was determined using an established reporter assay. Physiological cartilage osmolarity (i.e., physosmolarity) most prominently increased TGF-β2 mRNA expression and protein secretion as well as TGF-β bioactivity. Upon TGF-β2 isoform-specific knockdown, gene expression of chondrocyte marker COL2A1 was induced. TGF-β2 RNAi under physosmolarity enhanced TGF-β bioactivity. BMP bioactivity increased upon physosmotic treatment, but was not related to TGF-β2 RNAi. In contrast, dorsomorphin inhibited COL2A1 mRNA expression in human articular chondrocytes independent of the osmotic condition. Our data suggest a role for TGF-β superfamily member signaling in physosmolarity-induced mRNA expression of collagen type II. As physosmotic conditions favor the expression of COL2A1 independent of our manipulations, contribution of other metabolic, post-transcriptional or epigenetic factors cannot be excluded in the underlying complex and interdependent regulation of marker gene expression. Dissecting these molecular mechanisms holds potential to further improve future cell-based chondral repair strategies.
Collapse
|
77
|
Snijders TE, Willemsen K, van Gaalen SM, Castelein RM, Weinans H, de Gast A. Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review. Hip Int 2019; 29:41-50. [PMID: 29772949 DOI: 10.1177/1120700018759306] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: Dislocation is 1 of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. METHODS: A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. RESULTS: 28 relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. CONCLUSIONS: All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.
Collapse
|
78
|
Kozijn AE, Tartjiono MT, Ravipati S, van der Ham F, Barrett DA, Mastbergen SC, Korthagen NM, Lafeber FPJG, Zuurmond AM, Bobeldijk I, Weinans H, Stoop R. Human C-reactive protein aggravates osteoarthritis development in mice on a high-fat diet. Osteoarthritis Cartilage 2019; 27:118-128. [PMID: 30248505 DOI: 10.1016/j.joca.2018.09.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 07/17/2018] [Accepted: 09/13/2018] [Indexed: 02/02/2023]
Abstract
OBJECTIVE C-reactive protein (CRP) levels can be elevated in osteoarthritis (OA) patients. In addition to indicating systemic inflammation, it is suggested that CRP itself can play a role in OA development. Obesity and metabolic syndrome are important risk factors for OA and also induce elevated CRP levels. Here we evaluated in a human CRP (hCRP)-transgenic mouse model whether CRP itself contributes to the development of 'metabolic' OA. DESIGN Metabolic OA was induced by feeding 12-week-old hCRP-transgenic males (hCRP-tg, n = 30) and wild-type littermates (n = 15) a 45 kcal% high-fat diet (HFD) for 38 weeks. Cartilage degradation, osteophytes and synovitis were graded on Safranin O-stained histological knee joint sections. Inflammatory status was assessed by plasma lipid profiling, flow cytometric analyses of blood immune cell populations and immunohistochemical staining of synovial macrophage subsets. RESULTS Male hCRP-tg mice showed aggravated OA severity and increased osteophytosis compared with their wild-type littermates. Both classical and non-classical monocytes showed increased expression of CCR2 and CD86 in hCRP-tg males. HFD-induced effects were evident for nearly all lipids measured and indicated a similar low-grade systemic inflammation for both genotypes. Synovitis scores and synovial macrophage subsets were similar in the two groups. CONCLUSIONS Human CRP expression in a background of HFD-induced metabolic dysfunction resulted in the aggravation of OA through increased cartilage degeneration and osteophytosis. Increased recruitment of classical and non-classical monocytes might be a mechanism of action through which CRP is involved in aggravating this process. These findings suggest interventions selectively directed against CRP activity could ameliorate metabolic OA development.
Collapse
|
79
|
Longoni A, Knežević L, Schepers K, Weinans H, Rosenberg AJWP, Gawlitta D. The impact of immune response on endochondral bone regeneration. NPJ Regen Med 2018; 3:22. [PMID: 30510772 PMCID: PMC6265275 DOI: 10.1038/s41536-018-0060-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 10/26/2018] [Indexed: 12/29/2022] Open
Abstract
Tissue engineered cartilage substitutes, which induce the process of endochondral ossification, represent a regenerative strategy for bone defect healing. Such constructs typically consist of multipotent mesenchymal stromal cells (MSCs) forming a cartilage template in vitro, which can be implanted to stimulate bone formation in vivo. The use of MSCs of allogeneic origin could potentially improve the clinical utility of the tissue engineered cartilage constructs in three ways. First, ready-to-use construct availability can speed up the treatment process. Second, MSCs derived and expanded from a single donor could be applied to treat several patients and thus the costs of the medical interventions would decrease. Finally, it would allow more control over the quality of the MSC chondrogenic differentiation. However, even though the envisaged clinical use of allogeneic cell sources for bone regeneration is advantageous, their immunogenicity poses a significant obstacle to their clinical application. The aim of this review is to increase the awareness of the role played by immune cells during endochondral ossification, and in particular during regenerative strategies when the immune response is altered by the presence of implanted biomaterials and/or cells. More specifically, we focus on how this balance between immune response and bone regeneration is affected by the implantation of a cartilaginous tissue engineered construct of allogeneic origin.
Collapse
|
80
|
Tümer N, Arbabi V, Gielis WP, de Jong PA, Weinans H, Tuijthof GJM, Zadpoor AA. Three-dimensional analysis of shape variations and symmetry of the fibula, tibia, calcaneus and talus. J Anat 2018; 234:132-144. [PMID: 30393864 PMCID: PMC6284442 DOI: 10.1111/joa.12900] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/29/2018] [Indexed: 12/01/2022] Open
Abstract
The bones forming the talocrural joint (TCJ) and subtalar joint (STJ) are often assumed to be bilaterally symmetric. Therefore, the contralateral limb (i.e. the fibula, tibia, calcaneus and talus) is used as a template or an intra‐subject control in clinical and research practice. However, the validity of the symmetry assumption is controversial, because insufficient information is available on the shape variations and bilateral (a)symmetry of the fibula, tibia, calcaneus and talus. Using three‐dimensional spatially dense sampled representations of bone shapes extracted from bilateral computed tomography scans of 66 individuals (55 male, mean age: 61 ± 10 years; 11 female, mean age: 53 ± 15 years), we analyzed whether: (i) similar shape patterns exist in the left and right bones of the same type; (ii) gender has an effect on bone shape variations; (iii) intra‐subject shape variation is smaller than that of inter‐subject for a given shape variance direction. For the first set of analyses, all left and right instances of the same type of bone were considered as two separate groups, and statistically compared with each other on multiple aspects including group location (central tendency), variance‐covariance scale (dispersion) and orientation (covariance structure) using distance‐based permutational tests. For the second and third sets of analyses, all left and right bones of the same type were pooled into one group, and shape variations in the TCJ and STJ bones were extracted using principal component analysis. The effects of gender on age‐adjusted bone shape differences were assessed using an analysis of covariance. Moreover, intra‐class correlation was employed to evaluate intra‐ and inter‐subject bone shape variations. For each bone type, both sides had similar shape patterns (Ppermutational‐values > 0.05). After Bonferroni adjustment, gender led to shape differences, which were mainly in the lateral and medial condyles of the tibia (P = 0.003), the length and height of the calcaneus (P < 0.001), the posterior and anterior talar articular surfaces of the calcaneus (P = 0.001), and in the posterior aspect of the talus (P = 0.001). Intra‐subject shape variations in the tibial tuberosity together with the diameter of the tibia, and the curvature of the fibula shaft and the diameter of the fibula were as high as those of inter‐subject. This result suggests that the shape symmetry assumption could be violated for some specific shape variations in the fibula and tibia.
Collapse
|
81
|
Croes M, de Visser H, Meij BP, Lietart K, van der Wal BCH, Vogely HC, Fluit AC, Boel CHE, Alblas J, Weinans H, Amin Yavari S. Data on a rat infection model to assess porous titanium implant coatings. Data Brief 2018; 21:1642-1648. [PMID: 30505893 PMCID: PMC6247446 DOI: 10.1016/j.dib.2018.10.157] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 10/26/2018] [Accepted: 10/30/2018] [Indexed: 10/31/2022] Open
Abstract
A model is needed to study the effectiveness of different anti-bacterial coatings on complex metal implants in a bone environment. This article shares data on the design of porous titanium implants for intramedullary implantation in the proximal rat tibia. The implant length, diameter and porosity were optimized after testing on cadaveric specimens. This article shares data on which parameters are critical to establish a chronic implant infection in Sprague Dawley rats when using the new implant design. To this end, different strains of Staphylococcus aureus and inoculation doses were investigated.
Collapse
|
82
|
Mirzaali MJ, van Dongen ICP, Tümer N, Weinans H, Yavari SA, Zadpoor AA. In-silico quest for bactericidal but non-cytotoxic nanopatterns. NANOTECHNOLOGY 2018; 29:43LT02. [PMID: 30152409 DOI: 10.1088/1361-6528/aad9bf] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Nanopillar arrays that are bactericidal but not cytotoxic against the host cells could be used in implantable medical devices to prevent implant-associated infections. It is, however, unclear what heights, widths, interspacing, and shape should be used for the nanopillars to achieve the desired antibacterial effects while not hampering the integration of the device in the body. Here, we present an in-silico approach based on finite element modeling of the interactions between Staphylococcus aureus and nanopatterns on the one hand and osteoblasts and nanopatterns on the other hand to find the best design parameters. We found that while the height of the nanopillars seems to have little impact on the bactericidal behavior, shorter widths and larger interspacings substantially increase the bactericidal effects. The same combination of parameters could, however, also cause cytotoxicity. Our results suggest that a specific combination of height (120 nm), width (50 nm), and interspacing (300 nm) offers the bactericidal effects without cytotoxicity.
Collapse
|
83
|
Akhavan B, Bakhshandeh S, Najafi-Ashtiani H, Fluit AC, Boel E, Vogely C, van der Wal BCH, Zadpoor AA, Weinans H, Hennink WE, Bilek MM, Amin Yavari S. Direct covalent attachment of silver nanoparticles on radical-rich plasma polymer films for antibacterial applications. J Mater Chem B 2018; 6:5845-5853. [PMID: 32254705 DOI: 10.1039/c8tb01363b] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Prevention and treatment of biomaterial-associated infections (BAI) are imperative requirements for the effective and long-lasting function of orthopedic implants. Surface-functionalization of these materials with antibacterial agents, such as antibiotics, nanoparticles and peptides, is a promising approach to combat BAI. The well-known silver nanoparticles (AgNPs) in particular, although benefiting from strong and broad-range antibacterial efficiency, have been frequently associated with mammalian cell toxicity when physically adsorbed on biomaterials. The majority of irreversible immobilization techniques employed to fabricate AgNP-functionalized surfaces are based on wet-chemistry methods. However, these methods are typically substrate-dependent, complex, and time-consuming. Here we present a simple and dry strategy for the development of polymeric coatings used as platforms for the direct, linker-free covalent attachment of AgNPs onto solid surfaces using ion-assisted plasma polymerization. The resulting coating not only exhibits long-term antibiofilm efficiency against adherent Staphylococcus aureus (S. aureus), but also enhances osteoblast adhesion and proliferation. High resolution X-ray photoelectron spectroscopy (XPS), before and after sodium dodecyl sulfate (SDS) washing, confirms covalent bonding. The development of such silver-functionalized surfaces through a simple, plasma-based process holds great promise for the fabrication of implantable devices with improved tissue-implant integration and reduced biomaterial associated infections.
Collapse
|
84
|
Snijders T, Schlösser T, van Gaalen S, Castelein R, Weinans H, de Gast A. Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles. JB JS Open Access 2018; 3:e0063. [PMID: 30533596 PMCID: PMC6242317 DOI: 10.2106/jbjs.oa.17.00063] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept involving a trigonometric description enables unambiguous definitions. Our objective was to test the validity and reliability of a 3D trigonometric description of cup orientation. METHODS Computed tomographic scans of the pelvis, performed for vascular assessment of 20 patients with 22 primary total hip replacements in situ, were systematically collected. On multiplanar reconstructions, 3 observers independently measured cup orientation retrospectively in terms of coronal inclination, sagittal tilt, and transverse version. The angles measured in 2 planes were used to calculate the angle in the third plane via a trigonometric algorithm. For correlation and reliability analyses, intraobserver and interobserver differences between measured and calculated angles were evaluated with use of the intraclass correlation coefficient (ICC). RESULTS Measured and calculated angles had ICCs of 0.953 for coronal inclination, 0.985 for sagittal tilt, and 0.982 for transverse version. Intraobserver and interobserver reliability had ICCs of 0.987 and 0.987, respectively, for coronal inclination; 0.979 and 0.981, respectively, for sagittal tilt; and 0.992 and 0.978, respectively, for transverse version. CONCLUSIONS The 3D concept with its trigonometric algorithm is a valid and reliable tool for the measurement of cup orientation. CLINICAL RELEVANCE By calculating the transverse version of cups from coronal inclination and sagittal tilt measurements, the trigonometric algorithm enables a 3D definition of cup orientation, regardless of the imaging modality used. In addition, it introduces sagittal tilt that, like pelvic tilt, rotates around the transverse axis.
Collapse
|
85
|
Li Y, Jahr H, Lietaert K, Pavanram P, Yilmaz A, Fockaert LI, Leeflang MA, Pouran B, Gonzalez-Garcia Y, Weinans H, Mol JMC, Zhou J, Zadpoor AA. Additively manufactured biodegradable porous iron. Acta Biomater 2018; 77:380-393. [PMID: 29981948 DOI: 10.1016/j.actbio.2018.07.011] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 06/14/2018] [Accepted: 07/05/2018] [Indexed: 01/14/2023]
Abstract
Additively manufactured (AM) topologically ordered porous metallic biomaterials with the proper biodegradation profile offer a unique combination of properties ideal for bone regeneration. These include a fully interconnected porous structure, bone-mimicking mechanical properties, and the possibility of fully regenerating bony defects. Most of such biomaterials are, however, based on magnesium and, thus, degrade too fast. Here, we present the first report on topologically ordered porous iron made by Direct Metal Printing (DMP). The topological design was based on a repetitive diamond unit cell. We conducted a comprehensive study on the in vitro biodegradation behavior (up to 28 days), electrochemical performance, time-dependent mechanical properties, and biocompatibility of the scaffolds. The mechanical properties of AM porous iron (E = 1600-1800 MPa) were still within the range of the values reported for trabecular bone after 28 days of biodegradation. Electrochemical tests showed up to ≈12 times higher rates of biodegradation for AM porous iron as compared to that of cold-rolled (CR) iron, while only 3.1% of weight loss was measured after 4 weeks of immersion tests. The biodegradation mechanisms were found to be topology-dependent and different between the periphery and central parts of the scaffolds. While direct contact between MG-63 cells and scaffolds revealed substantial and almost instant cytotoxicity in static cell culture, as compared to Ti-6Al-4V, the cytocompatibility according to ISO 10993 was reasonable in in vitro assays for up to 72 h. This study shows how DMP could be used to increase the surface area and decrease the grain sizes of topologically ordered porous metallic biomaterials made from metals that are usually considered to degrade too slowly (e.g., iron), opening up many new opportunities for the development of biodegradable metallic biomaterials. STATEMENT OF SIGNIFICANCE Biodegradation in general and proper biodegradation profile in particular are perhaps the most important requirements that additively manufactured (AM) topologically ordered porous metallic biomaterials should offer in order to become the ideal biomaterial for bone regeneration. Currently, most biodegradable metallic biomaterials are based on magnesium, which degrade fast with gas generation. Here, we present the first report on topologically ordered porous iron made by Direct Metal Printing (DMP). We also conducted a comprehensive study on the biodegradation behavior, electrochemical performance, biocompatibility, and the time evolution of the mechanical properties of the implants. We show that these implants possess bone-mimicking mechanical properties, accelerated degradation rate, and reasonable cytocompatibility, opening up many new opportunities for the development of iron-based biodegradable materials.
Collapse
|
86
|
van Midwoud PM, Sandker M, Hennink WE, de Leede LGJ, Chan A, Weinans H. In vivo pharmacokinetics of celecoxib loaded endcapped PCLA-PEG-PCLA thermogels in rats after subcutaneous administration. Eur J Pharm Biopharm 2018; 131:170-177. [PMID: 30075312 DOI: 10.1016/j.ejpb.2018.07.026] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 07/27/2018] [Accepted: 07/30/2018] [Indexed: 12/16/2022]
Abstract
Injectable thermogels based on poly(ε-caprolactone-co-lactide)-b-poly(ethylene glycol)-b-poly(ε-caprolactone-co-lactide) (PCLA-PEG-PCLA) containing an acetyl- or propyl endcap and loaded with celecoxib were developed for local drug release. The aim of this study was to determine the effects of the composition of the celecoxib/PCLA-PEG-PCLA formulation on their in vivo drug release characteristics. Furthermore, we want to obtain insight into the in vitro-in vivo correlation. Different formulations were injected subcutaneously in rats and blood samples were taken for a period of 8 weeks. Celecoxib half-life in blood increased from 5 h for the bolus injection of celecoxib to more than 10 days for the slowest releasing gel formulation. Sustained release of celecoxib was obtained for at least 8 weeks after subcutaneous administration. The release period was prolonged from 3 to 6-8 weeks by increasing the injected volume from 100 to 500 µL, which also led to higher serum concentrations in time. Propyl endcapping of the polymer also led to a prolonged release compared to the acetyl endcapped polymer (49 versus 21 days) and at equal injected dose of the drug in lower serum concentrations. Increasing the celecoxib loading from 10 mg/mL to 50 mg/mL surprisingly led to prolonged release (28 versus 56 days) as well as higher serum concentrations per time point, even when corrected for the higher dose applied. The in vivo release was about twice as fast compared to the in vitro release for all formulations. Imaging of organs of mice, harvested 15 weeks after subcutaneous injection with polymer solution loaded with infrared-780 labelled dye showed no accumulation in any of these harvested organs except for traces in the kidneys, indicating renal clearance. Due to its simplicity and versatility, this drug delivery system has great potential for designing an injectable to locally treat osteoarthritis, and to enable tuning the gel to meet patient-specific needs.
Collapse
|
87
|
Pouran B, Moshtagh PR, Arbabi V, Snabel J, Stoop R, Ruberti J, Malda J, Zadpoor AA, Weinans H. Non-enzymatic cross-linking of collagen type II fibrils is tuned via osmolality switch. J Orthop Res 2018; 36:1929-1936. [PMID: 29334127 PMCID: PMC6099510 DOI: 10.1002/jor.23857] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 01/08/2018] [Indexed: 02/04/2023]
Abstract
An important aspect in cartilage ageing is accumulation of advanced glycation end products (AGEs) after exposure to sugars. Advanced glycation results in cross-links formation between the collagen fibrils in articular cartilage, hampering their flexibility and making cartilage more brittle. In the current study, we investigate whether collagen cross-linking after exposure to sugars depends on the stretching condition of the collagen fibrils. Healthy equine cartilage specimens were exposed to l-threose sugar and placed in hypo-, iso-, or hyper-osmolal conditions that expanded or shrank the tissue and changed the 3D conformation of collagen fibrils. We applied micro-indentation tests, contrast enhanced micro-computed tomography, biochemical measurement of pentosidine cross-links, and cartilage surface color analysis to assess the effects of advanced glycation cross-linking under these different conditions. Swelling of extracellular matrix due to hypo-osmolality made cartilage less susceptible to advanced glycation, namely, the increase in effective Young's modulus was approximately 80% lower in hypo-osmolality compared to hyper-osmolality and pentosidine content per collagen was 47% lower. These results indicate that healthy levels of glycosaminoglycans not only keep cartilage stiffness at appropriate levels by swelling and pre-stressed collagen fibrils, but also protect collagen fibrils from adverse effects of advanced glycation. These findings highlight the fact that collagen fibrils and therefore cartilage can be protected from further advanced glycation ("ageing") by maintaining the joint environment at sufficiently low osmolality. Understanding of mechanochemistry of collagen fibrils provided here might evoke potential ageing prohibiting strategies against cartilage deterioration. © 2018 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 36:1929-1936, 2018.
Collapse
|
88
|
Sandker MJ, Duque LF, Redout EM, Klijnstra EC, Steendam R, Kops N, Waarsing JH, van Weeren R, Hennink WE, Weinans H. Degradation, Intra-Articular Biocompatibility, Drug Release, and Bioactivity of Tacrolimus-Loaded Poly(d-l-lactide-PEG)-b-poly(l-lactide) Multiblock Copolymer-Based Monospheres. ACS Biomater Sci Eng 2018; 4:2390-2403. [DOI: 10.1021/acsbiomaterials.8b00116] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
89
|
de Visser HM, Mastbergen SC, Ravipati S, Welsing PMJ, Pinto FC, Lafeber FPJG, Chapman V, Barrett DA, Weinans H. Local and systemic inflammatory lipid profiling in a rat model of osteoarthritis with metabolic dysregulation. PLoS One 2018; 13:e0196308. [PMID: 29684084 PMCID: PMC5912715 DOI: 10.1371/journal.pone.0196308] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 04/10/2018] [Indexed: 01/15/2023] Open
Abstract
Objective Bioactive oxidised lipids (oxylipins) are important signalling mediators, capable of modulating the inflammatory state of the joint and anticipated to be of importance in joint homeostasis and status of osteoarthritis. The aim of this study was to quantify oxylipin levels in plasma and synovial fluid from rats with experimentally induced osteoarthritis to investigate the potential role of oxylipins as a marker in the disease process of early osteoarthritis. Design Forty rats were randomly allocated to a standard or high-fat diet group. After 12 weeks, local cartilage damage was induced in one knee joint in 14 rats of each diet group. The remaining 6 rats per group served as controls. At week 24, samples were collected. Oxylipin levels were quantified by liquid chromatography–mass spectrometry. Results Overall, 31 lipid-derived inflammatory mediators were detected in fasted plasma and synovial fluid. Principal component analysis identified four distinct clusters associated with histopathological changes. Diet induced differences were evident for 13 individual plasma oxylipins, as well as 5,6-EET in synovial fluid. Surgical-model induced differences were evident for three oxylipins in synovial fluid (15-HETE, 8,9-DHET and 17R-ResolvinD1) with a different response in lipid concentrations for synovial fluid and plasma. Conclusions We demonstrate the quantification of oxidised lipids in rat plasma and synovial fluid in a model of early experimental osteoarthritis. Oxylipins in the synovial fluid that were altered as consequence of the surgically induced osteoarthritis were not represented in the plasma. Our findings suggest differential roles of the oxylipins in the local versus peripheral compartment.
Collapse
|
90
|
de Visser HM, Korthagen NM, Müller C, Ramakers RM, Krijger GC, Lafeber FPJG, Beekman FJ, Mastbergen SC, Weinans H. Imaging of Folate Receptor Expressing Macrophages in the Rat Groove Model of Osteoarthritis: Using a New DOTA-Folate Conjugate. Cartilage 2018; 9:183-191. [PMID: 29096521 PMCID: PMC5871123 DOI: 10.1177/1947603517738073] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective To evaluate the presence and localization of folate receptor expressing macrophages in the rat groove model of osteoarthritis and determine the suitability of a new folate conjugate with albumin-binding entity (cm09) for in vivo SPECT (single-photon emission computed tomography) analysis. Design In male Wistar rats, local cartilage damage was induced in addition to a standard ( n = 10) or high-fat diet ( n = 6). After 12 weeks, 111In labeled folate conjugates were administered, and SPECT/CT (computed tomography) imaging was performed after 24 hours. Subsequently, osteoarthritis severity and folate receptor expression were assessed using (immuno)-histological sections. Results In vivo SPECT/CT imaging of the new folate conjugate (cm09) was as useful as a folate conjugate without albumin-binding entity in the groove model of osteoarthritis with less renal accumulation. Induction of cartilage damage on a standard diet resulted in no effect on the amount of folate receptor expressing macrophages compared with the contralateral sham operated joints. In contrast, inducing cartilage damage in the high-fat diet group resulted in 28.4% increase of folate receptor expression as compared with the nondamaged control joints. Folate receptor expressing cells were predominantly present in the synovial lining and in subchondral bone as confirmed by immunohistochemistry. Conclusions Folate receptor expression, and thus macrophage activation, can clearly be demonstrated in vivo, in small animal models of osteoarthritis using the new 111In-folate conjugate with specific binding to the folate receptor. Increased macrophage activity only plays a role in the groove model of osteoarthritis when applied in a high-fat diet induced dysmetabolic condition, which is in line with the higher inflammatory state of that specific model.
Collapse
|
91
|
Hedayati R, Ahmadi S, Lietaert K, Pouran B, Li Y, Weinans H, Rans C, Zadpoor A. Isolated and modulated effects of topology and material type on the mechanical properties of additively manufactured porous biomaterials. J Mech Behav Biomed Mater 2018; 79:254-263. [DOI: 10.1016/j.jmbbm.2017.12.029] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 12/22/2017] [Accepted: 12/28/2017] [Indexed: 11/29/2022]
|
92
|
de Visser HM, Mastbergen SC, Kozijn AE, Coeleveld K, Pouran B, van Rijen MH, Lafeber FPJG, Weinans H. Metabolic dysregulation accelerates injury-induced joint degeneration, driven by local inflammation; an in vivo rat study. J Orthop Res 2018; 36:881-890. [PMID: 28840952 DOI: 10.1002/jor.23712] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Accepted: 08/19/2017] [Indexed: 02/04/2023]
Abstract
Evidence is growing for the existence of an obesity-related phenotype of osteoarthritis in which low-grade inflammation and a disturbed metabolic profile play a role. The contribution of an obesity-induced metabolic dysbalance to the progression of the features of osteoarthritis upon mechanically induced cartilage damage was studied in a rat in vivo model. Forty Wistar rats were randomly allocated 1:1 to a standard diet or a high-fat diet. After 12 weeks, in 14 out of 20 rats in each group, cartilage was mechanically damaged in the right knee joint. The remaining six animals in each group served as controls. After a subsequent 12 weeks, serum was collected for metabolic state, subchondral bone changes assessed by μCT imaging, osteoarthritis severity determined by histology, and macrophage presence assessed by CD68 staining. The high-fat diet increased statistically all relevant metabolic parameters, resulting in a dysmetabolic state and subsequent synovial inflammation, whereas cartilage degeneration was hardly influenced. The high-fat condition in combination with mechanical cartilage damage resulted in a clear statistically significant progression of the osteoarthritic features, with increased synovitis and multiple large osteophytes. Both the synovium and osteophytes contained numerous CD68 positive cells. It is concluded that a metabolic dysbalance due to a high-fat diet increases joint inflammation without cartilage degeneration. The dysmetabolic state clearly accelerates progression of osteoarthritis upon surgically induced cartilage damage supported by inflammatory responses as demonstrated by histology and increased CD68 expressing cells localized on the synovial membrane and osteophytes. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:881-890, 2018.
Collapse
|
93
|
Li Y, Zhou J, Pavanram P, Leeflang M, Fockaert L, Pouran B, Tümer N, Schröder KU, Mol J, Weinans H, Jahr H, Zadpoor A. Additively manufactured biodegradable porous magnesium. Acta Biomater 2018; 67:378-392. [PMID: 29242158 DOI: 10.1016/j.actbio.2017.12.008] [Citation(s) in RCA: 111] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 12/01/2017] [Accepted: 12/04/2017] [Indexed: 01/11/2023]
Abstract
An ideal bone substituting material should be bone-mimicking in terms of mechanical properties, present a precisely controlled and fully interconnected porous structure, and degrade in the human body to allow for full regeneration of large bony defects. However, simultaneously satisfying all these three requirements has so far been highly challenging. Here we present topologically ordered porous magnesium (WE43) scaffolds based on the diamond unit cell that were fabricated by selective laser melting (SLM) and satisfy all the requirements. We studied the in vitro biodegradation behavior (up to 4 weeks), mechanical properties and biocompatibility of the developed scaffolds. The mechanical properties of the AM porous WE43 (E = 700-800 MPa) scaffolds were found to fall into the range of the values reported for trabecular bone even after 4 weeks of biodegradation. Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical tests and µCT revealed a unique biodegradation mechanism that started with uniform corrosion, followed by localized corrosion, particularly in the center of the scaffolds. Biocompatibility tests performed up to 72 h showed level 0 cytotoxicity (according to ISO 10993-5 and -12), except for one time point (i.e., 24 h). Intimate contact between cells (MG-63) and the scaffolds was also observed in SEM images. The study shows for the first time that AM of porous Mg may provide distinct possibilities to adjust biodegradation profile through topological design and open up unprecedented opportunities to develop multifunctional bone substituting materials that mimic bone properties and enable full regeneration of critical-size load-bearing bony defects. STATEMENT OF SIGNIFICANCE The ideal biomaterials for bone tissue regeneration should be bone-mimicking in terms of mechanical properties, present a fully interconnected porous structure, and exhibit a specific biodegradation behavior to enable full regeneration of bony defects. Recent advances in additive manufacturing have resulted in biomaterials that satisfy the first two requirements but simultaneously satisfying the third requirement has proven challenging so far. Here we present additively manufactured porous magnesium structures that have the potential to satisfy all above-mentioned requirements. Even after 4 weeks of biodegradation, the mechanical properties of the porous structures were found to be within those reported for native bone. Moreover, our comprehensive electrochemical, mechanical, topological, and biological study revealed a unique biodegradation behavior and the limited cytotoxicity of the developed biomaterials.
Collapse
|
94
|
Moshtagh PR, Korthagen NM, Plomp SG, Pouran B, Castelein RM, Zadpoor AA, Weinans H. Early Signs of Bone and Cartilage Changes Induced by Treadmill Exercise in Rats. JBMR Plus 2018; 2:134-142. [PMID: 30283898 DOI: 10.1002/jbm4.10029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 12/02/2017] [Accepted: 12/12/2017] [Indexed: 12/14/2022] Open
Abstract
This study aims to investigate the earliest alterations of bone and cartilage tissues as a result of different exercise protocols in the knee joint of Wistar rats. We hypothesize that pretraining to a continuous intense running protocol would protect the animals from cartilage degeneration. Three groups of animals were used: (i) an adaptive (pretraining) running group that ran for 8 weeks with gradually increasing velocity and time of running followed by a constant running program (6 weeks of 1.12 km/hour running per day); (ii) a non-adaptive running (constant running) group that initially rested for 8 weeks followed by 6 weeks of constant running; and (iii) a non-running (control) group. At weeks 8, 14, and 20 bone and cartilage were analyzed. Both running groups developed mild symptoms of cartilage irregularities, such as chondrocyte hypertrophy and cell clustering in different cartilage zones, in particular after the adaptive running protocol. As a result of physical training in the adaptive running exercise a dynamic response of bone was detected at week 8, where bone growth was enhanced. Conversely, the thickness of epiphyseal trabecular and subchondral bone (at week 14) was reduced due to the constant running in the period between 8 and 14 weeks. Finally, the intermediate differences between the two running groups disappeared after both groups had a resting period (from 14 to 20 weeks). The adaptive running group showed an increase in aggrecan gene expression and reduction of MMP2 expression after the initial 8 weeks running. Thus, the running exercise models in this study showed mild bone and cartilage/chondrocyte alterations that can be considered as early-stage osteoarthritis. The pretraining adaptive protocol before constant intense running did not protect from mild cartilage degeneration. © 2017 The Authors. JBMR Plus is published by Wiley Periodicals, Inc. on behalf of American Society for Bone and Mineral Research.
Collapse
|
95
|
Ahmadi S, Hedayati R, Li Y, Lietaert K, Tümer N, Fatemi A, Rans C, Pouran B, Weinans H, Zadpoor A. Fatigue performance of additively manufactured meta-biomaterials: The effects of topology and material type. Acta Biomater 2018; 65:292-304. [PMID: 29127065 DOI: 10.1016/j.actbio.2017.11.014] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 11/03/2017] [Accepted: 11/07/2017] [Indexed: 01/13/2023]
Abstract
Additive manufacturing (AM) techniques enable fabrication of bone-mimicking meta-biomaterials with unprecedented combinations of topological, mechanical, and mass transport properties. The mechanical performance of AM meta-biomaterials is a direct function of their topological design. It is, however, not clear to what extent the material type is important in determining the fatigue behavior of such biomaterials. We therefore aimed to determine the isolated and modulated effects of topological design and material type on the fatigue response of metallic meta-biomaterials fabricated with selective laser melting. Towards that end, we designed and additively manufactured Co-Cr meta-biomaterials with three types of repeating unit cells and three to four porosities per type of repeating unit cell. The AM meta-biomaterials were then mechanically tested to obtain their normalized S-N curves. The obtained S-N curves of Co-Cr meta-biomaterials were compared to those of meta-biomaterials with same topological designs but made from other materials, i.e. Ti-6Al-4V, tantalum, and pure titanium, available from our previous studies. We found the material type to be far more important than the topological design in determining the normalized fatigue strength of our AM metallic meta-biomaterials. This is the opposite of what we have found for the quasi-static mechanical properties of the same meta-biomaterials. The effects of material type, manufacturing imperfections, and topological design were different in the high and low cycle fatigue regions. That is likely because the cyclic response of meta-biomaterials depends not only on the static and fatigue strengths of the bulk material but also on other factors that may include strut roughness, distribution of the micro-pores created inside the struts during the AM process, and plasticity. STATEMENT OF SIGNIFICANCE Meta-biomaterials are a special class of metamaterials with unusual or unprecedented combinations of mechanical, physical (e.g. mass transport), and biological properties. Topologically complex and additively manufactured meta-biomaterials have been shown to improve bone regeneration and osseointegration. The mechanical properties of such biomaterials are directly related to their topological design and material type. However, previous studies of such biomaterials have largely neglected the effects of material type, instead focusing on topological design. We show here that neglecting the effects of material type is unjustified. We studied the isolated and combined effects of topological design and material type on the normalized S-N curves of metallic bone-mimicking biomaterials and found them to be more strongly dependent on the material type than topological design.
Collapse
|
96
|
Kozijn AE, Gierman LM, van der Ham F, Mulder P, Morrison MC, Kühnast S, van der Heijden RA, Stavro PM, van Koppen A, Pieterman EJ, van den Hoek AM, Kleemann R, Princen HMG, Mastbergen SC, Lafeber FPJG, Zuurmond AM, Bobeldijk I, Weinans H, Stoop R. Variable cartilage degradation in mice with diet-induced metabolic dysfunction: food for thought. Osteoarthritis Cartilage 2018; 26:95-107. [PMID: 29074298 DOI: 10.1016/j.joca.2017.10.010] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 10/03/2017] [Accepted: 10/10/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Human cohort studies have demonstrated a role for systemic metabolic dysfunction in osteoarthritis (OA) pathogenesis in obese patients. To explore the mechanisms underlying this metabolic phenotype of OA, we examined cartilage degradation in the knees of mice from different genetic backgrounds in which a metabolic phenotype was established by various dietary approaches. DESIGN Wild-type C57BL/6J mice and genetically modified mice (hCRP, LDLr-/-. Leiden and ApoE*3Leiden.CETP mice) based on C57BL/6J background were used to investigate the contribution of inflammation and altered lipoprotein handling on diet-induced cartilage degradation. High-caloric diets of different macronutrient composition (i.e., high-carbohydrate or high-fat) were given in regimens of varying duration to induce a metabolic phenotype with aggravated cartilage degradation relative to controls. RESULTS Metabolic phenotypes were confirmed in all studies as mice developed obesity, hypercholesteremia, glucose intolerance and/or insulin resistance. Aggravated cartilage degradation was only observed in two out of the twelve experimental setups, specifically in long-term studies in male hCRP and female ApoE*3Leiden.CETP mice. C57BL/6J and LDLr-/-. Leiden mice did not develop HFD-induced OA under the conditions studied. Osteophyte formation and synovitis scores showed variable results between studies, but also between strains and gender. CONCLUSIONS Long-term feeding of high-caloric diets consistently induced a metabolic phenotype in various C57BL/6J (-based) mouse strains. In contrast, the induction of articular cartilage degradation proved variable, which suggests that an additional trigger might be necessary to accelerate diet-induced OA progression. Gender and genetic modifications that result in a humanized pro-inflammatory state (human CRP) or lipoprotein metabolism (human-E3L.CETP) were identified as important contributing factors.
Collapse
|
97
|
Koolen MKE, Kruyt MC, Zadpoor AA, Öner FC, Weinans H, van der Jagt OP. Optimization of screw fixation in rat bone with extracorporeal shock waves. J Orthop Res 2018; 36:76-84. [PMID: 28543599 DOI: 10.1002/jor.23615] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2017] [Accepted: 05/19/2017] [Indexed: 02/04/2023]
Abstract
Screw fixation in osteoporotic patients is becoming an increasing problem in orthopaedic surgery as deterioration of cortical and cancellous bone hamper biomechanical stability and screw fixation. This might result in delayed weight-bearing or failure of instrumentation. We hypothesized that local peri-operative shock wave treatment can optimize osseointegration and subsequent screw fixation. In eight female Wistar rats, two cancellous and two cortical bone screws were implanted in both femora and tibiae. Immediately after implantation, 3.000 unfocused extracorporeal shock waves (energy flux density 0.3 mJ/mm2 ) were applied to one side. The other side served as non-treated internal control. Evaluation of osseointegration was performed after 4 weeks with the use of microCT scanning, histology with fluorochrome labeling, and pull-out tests of the screws. Four weeks after extracorporeal shock wave treatment, treated legs exhibited increased bone formation and screw fixation around cortical screws as compared to the control legs. This was corroborated by an increased pull-out of the shock wave treated cortical screws. The cancellous bone screws appeared not to be sensitive for shock wave treatment. Formation of neocortices after shock wave therapy was observed in three of eight animals. Furthermore, de novo bone formation in the bone marrow was observed in some animals. The current study showed bone formation and improved screw fixation as a result of shock wave therapy. New bone was also formed at locations remote from the screws, hence, not contributing to screw fixation. Further, research is warranted to make shock wave therapy tailor-made for fracture fixation. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:76-84, 2018.
Collapse
|
98
|
Gielis WP, Welsing PMJ, van Spil WE, Runhaar J, Weinans H, de Jong PA. A sex-specific association between incident radiographic osteoarthritis of hip or knee and incident peripheral arterial calcifications: 8-year prospective data from Cohort Hip and Cohort Knee (CHECK). Osteoarthritis Cartilage 2017; 25:1814-1821. [PMID: 28757188 DOI: 10.1016/j.joca.2017.07.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 05/26/2017] [Accepted: 07/19/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVES There is sparse evidence for a relationship between cardiovascular disease (CVD) and osteoarthritis (OA). We investigated the association between incidence of arterial calcifications and incidence of radiographic knee and/or hip OA. DESIGN We used baseline and 8-year follow-up data of Cohort Hip and Cohort Knee (CHECK). Knees and hips were either Kellgren-Lawrence (KL) grade 0 or 1 at baseline. Arterial calcifications were scored on hip and knee radiographs using a four-grade scale. Scores were summed for patient-level analyses. To investigate incidence, participants with arterial calcifications at baseline or missing follow-up were excluded. Incident OA was defined per joint as KL ≥ 2 or prosthesis at year eight. The association between incidenct of arterial calcifications and incident OA was studied using mixed-effects logistic regression. RESULTS Of 763 participants included, 623 (82%) were women. Mean (sd) age was 56 (5.1) years, mean (sd) body mass index (BMI) 26.2 (4.1) kg/m2. Arterial calcifications developed in 174 participants (283 joints). OA developed in 456 participants (778 joints). Sex modified the association between arterial calcification and OA. In women, incident arterial calcification around a joint was positively associated with incident OA in that joint (adjusted OR 2.51 (95% CI 1.57-4.03)). In men, no association was observed on joint-level, but at patient-level the arterial calcification sum score was negatively associated with incident OA (adjusted OR per point increase 0.70 (95% CI 0.54-0.90)) indicating a systemic effect. CONCLUSIONS We observed sex-dependent associations between incident arterial calcification and incident radiographic knee and/or hip OA, which differs between joint- and patient-level.
Collapse
|
99
|
Croes M, Boot W, Kruyt MC, Weinans H, Pouran B, van der Helm YJ, Gawlitta D, Vogely HC, Alblas J, Dhert WJ, Öner FC. Inflammation-Induced Osteogenesis in a Rabbit Tibia Model. Tissue Eng Part C Methods 2017. [DOI: 10.1089/ten.tec.2017.0151] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
|
100
|
Bakhshandeh S, Gorgin Karaji Z, Lietaert K, Fluit AC, Boel CH, Vogely HC, Vermonden T, Hennink WE, Weinans H, Zadpoor AA, Amin Yavari S. Simultaneous Delivery of Multiple Antibacterial Agents from Additively Manufactured Porous Biomaterials to Fully Eradicate Planktonic and Adherent Staphylococcus aureus. ACS APPLIED MATERIALS & INTERFACES 2017; 9:25691-25699. [PMID: 28696671 PMCID: PMC5553095 DOI: 10.1021/acsami.7b04950] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Accepted: 07/11/2017] [Indexed: 05/21/2023]
Abstract
Implant-associated infections are notoriously difficult to treat and may even result in amputation and death. The first few days after surgery are the most critical time to prevent those infections, preferably through full eradication of the micro-organisms entering the body perioperatively. That is particularly important for patients with a compromised immune system such as orthopedic oncology patients, as they are at higher risk for infection and complications. Full eradication of bacteria is, especially in a biofilm, extremely challenging due to the toxicity barrier that prevents delivery of high doses of antibacterial agents. This study aimed to use the potential synergistic effects of multiple antibacterial agents to prevent the use of toxic levels of these agents and achieve full eradication of planktonic and adherent bacteria. Silver ions and vancomycin were therefore simultaneously delivered from additively manufactured highly porous titanium implants with an extremely high surface area incorporating a bactericidal coating made from chitosan and gelatin applied by electrophoretic deposition (EPD). The presence of the chitosan/gelatin (Ch+Gel) coating, Ag, and vancomycin (Vanco) was confirmed by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). The release of vancomycin and silver ions continued for at least 21 days as measured by inductively coupled plasma (ICP) and UV-spectroscopy. Antibacterial behavior against Staphylococcus aureus, both planktonic and in biofilm, was evaluated for up to 21 days. The Ch+Gel coating showed some bactericidal behavior on its own, while the loaded hydrogels (Ch+Gel+Ag and Ch+Gel+Vanco) achieved full eradication of both planktonic and adherent bacteria without causing significant levels of toxicity. Combining silver and vancomycin improved the release profiles of both agents and revealed a synergistic behavior that further increased the bactericidal effects.
Collapse
|