Gruschwitz P, Hartung V, Kleefeldt F, Ergün S, Lichthardt S, Huflage H, Hendel R, Kunz AS, Pannenbecker P, Kuhl PJ, Augustin AM, Bley TA, Petritsch B, Grunz JP. Standardized assessment of vascular reconstruction kernels in photon-counting CT angiographies of the leg using a continuous extracorporeal perfusion model. Sci Rep 2023; 13:12109. [PMID: 37495759 PMCID: PMC10372012 DOI: 10.1038/s41598-023-39063-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 07/19/2023] [Indexed: 07/28/2023] Open
Abstract
This study evaluated the influence of different vascular reconstruction kernels on the image quality of CT angiographies of the lower extremity runoff using a 1st-generation photon-counting-detector CT (PCD-CT) compared with dose-matched examinations on a 3rd-generation energy-integrating-detector CT (EID-CT). Inducing continuous extracorporeal perfusion in a human cadaveric model, we performed CT angiographies of eight upper leg arterial runoffs with radiation dose-equivalent 120 kVp acquisition protocols (CTDIvol 5 mGy). Reconstructions were executed with different vascular kernels, matching the individual modulation transfer functions between scanners. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were computed to assess objective image quality. Six radiologists evaluated image quality subjectively using a forced-choice pairwise comparison tool. Interrater agreement was determined by calculating Kendall's concordance coefficient (W). The intraluminal attenuation of PCD-CT images was significantly higher than of EID-CT (414.7 ± 27.3 HU vs. 329.3 ± 24.5 HU; p < 0.001). Using comparable kernels, image noise with PCD-CT was significantly lower than with EID-CT (p ≤ 0.044). Correspondingly, SNR and CNR were approximately twofold higher for PCD-CT (p < 0.001). Increasing the spatial frequency for PCD-CT reconstructions by one level resulted in similar metrics compared to EID-CT (CNRfat; EID-CT Bv49: 21.7 ± 3.7 versus PCD-CT Bv60: 21.4 ± 3.5). Overall image quality of PCD-CTA achieved ratings superior to EID-CTA irrespective of the used reconstruction kernels (best: PCD-CT Bv60; worst: EID-CT Bv40; p < 0.001). Interrater agreement was good (W = 0.78). Concluding, PCD-CT offers superior intraluminal attenuation, SNR, and CNR compared to EID-CT in angiographies of the upper leg arterial runoff. Combined with improved subjective image quality, PCD-CT facilitates the use of sharper convolution kernels and ultimately bears the potential of improved vascular structure assessability.
Collapse
|
27
|
Elsner C, Kunz AS, Wagner N, Huflage H, Hübner S, Luetkens KS, Bley TA, Schmitt R, Ergün S, Grunz JP. MRI-Based Evaluation of the Flexor Digitorum Superficialis Anatomy: Investigating the Prevalence and Morphometry of the "Chiasma Antebrachii". Diagnostics (Basel) 2023; 13:2406. [PMID: 37510150 PMCID: PMC10378300 DOI: 10.3390/diagnostics13142406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 07/14/2023] [Accepted: 07/16/2023] [Indexed: 07/30/2023] Open
Abstract
Recent dissection studies resulted in the introduction of the term "chiasma antebrachii", which represents an intersection of the flexor digitorum superficialis (FDS) tendons for digits 2 and 3 in the distal third of the forearm. This retrospective investigation aimed to provide an MRI-based morphologic analysis of the chiasma antebrachii. In 89 patients (41 women, 39.3 ± 21.3 years), MRI examinations of the forearm (2010-2021) were reviewed by two radiologists, who evaluated all studies for the presence and length of the chiasma as well as its distance from the distal radioulnar and elbow joint. The chiasma antebrachii was identified in the distal third of the forearm in 88 patients (98.9%), while one intersection was located more proximally in the middle part. The chiasma had a median length of 28 mm (interquartile range: 24-35 mm). Its distances to the distal radioulnar and elbow joint were 16 mm (8-25 mm) and 215 mm (187-227 mm), respectively. T1-weighted post-contrast sequences were found to be superior to T2- or proton-density-weighted sequences in 71 cases (79.8%). To conclude, the chiasma antebrachii is part of the standard FDS anatomy. Knowledge of its morphology is important, e.g., in targeted injections of therapeutics or reconstructive surgery.
Collapse
|
28
|
Luetkens KS, Grunz JP, Kunz AS, Huflage H, Weißenberger M, Hartung V, Patzer TS, Gruschwitz P, Ergün S, Bley TA, Feldle P. Ultra-High-Resolution Photon-Counting Detector CT Arthrography of the Ankle: A Feasibility Study. Diagnostics (Basel) 2023; 13:2201. [PMID: 37443595 DOI: 10.3390/diagnostics13132201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 06/13/2023] [Accepted: 06/27/2023] [Indexed: 07/15/2023] Open
Abstract
This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ50; Br98: 39.0, Br84: 22.6, Br76: 16.5 lp/cm). Seven radiologists subjectively assessed the image quality regarding the depiction of bone, hyaline cartilage, and ligaments. An additional quantitative assessment comprised the measurement of noise and the computation of contrast-to-noise ratios (CNR). While an optimal depiction of bone tissue was achieved with the ultra-sharp Br98 kernel (S ≤ 0.043), the visualization of cartilage improved with lower modulation transfer functions at each dose level (p ≤ 0.014). The interrater reliability ranged from good to excellent for all assessed tissues (intraclass correlation coefficient ≥ 0.805). The noise levels in subcutaneous fat decreased with reduced spatial frequency (p < 0.001). Notably, the low-dose Br76 matched the CNR of the full-dose Br84 (p > 0.999) and superseded Br98 (p < 0.001) in all tissues. Based on the reported results, a photon-counting detector CT arthrography of the ankle with an ultra-high-resolution collimation offers stellar image quality and tissue assessability, improving the evaluation of miniscule anatomical structures. While bone depiction was superior in combination with an ultra-sharp convolution kernel, soft tissue evaluation benefited from employing a lower spatial frequency.
Collapse
|
29
|
Goertz L, Zopfs D, Pennig L, Jünger ST, Grunz JP, Timmer M, Görtz M, Huflage H, Luetkens KS, Kabbasch C, Zaeske C. Angiographic characteristics associated with rupture of small intracranial aneurysms. World Neurosurg 2023:S1878-8750(23)00849-5. [PMID: 37356486 DOI: 10.1016/j.wneu.2023.06.081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 06/17/2023] [Indexed: 06/27/2023]
Abstract
OBJECTIVE Contrary to previous assumptions, there is increasing evidence that small intracranial aneurysms carry a relevant risk of rupture. The aim of this study was to identify angiographic characteristics of small ruptured aneurysms ≤7 mm and to evaluate their significance for clinical decision making. METHODS A total of 385 patients with 149 unruptured and 236 ruptured intracranial aneurysms were retrospectively compared. Two- and three-dimensional digital subtraction angiography was used to determine aneurysm location, various size parameters, angulations, and morphology, as well as parent artery diameter. RESULTS Aneurysms of the anterior communicating artery, the posterior inferior cerebellar artery and the internal carotid artery terminus had a significantly increased prevalence among ruptured aneurysms. Ruptured aneurysms were characterized by a significantly larger aneurysm height (area-under-the curve [AUC] 0.60, p<0.01) and inclination angle (AUC 0.61, p=0.02) in addition to a smaller dome (AUC 0.44, p=0.02) and neck width (AUC 0.38, p<0.01). Calculation of size ratios increases the predictive value for aneurysm rupture, with AUC-values of 0.77 for aspect ratio (p<0.01) and 0.76 for size ratio (p<0.01). Aneurysm morphology was not a significant factor after multivariable adjustment (p=0.92). Arterial hypertension was the only clinical risk factor significantly associated with rupture (p<0.01). CONCLUSIONS Of the numerous factors associated with aneurysm rupture, we propose aneurysmal location, aspect ratio (cut-off: 1.5), and inclination angle as the most important morphological factors for assessing the rupture risk of small aneurysms because these factors have high AUC values and are robust to changes after rupture.
Collapse
|
30
|
Gruschwitz P, Hartung V, Kleefeldt F, Peter D, Lichthardt S, Huflage H, Grunz JP, Augustin AM, Ergün S, Bley TA, Petritsch B. Continuous extracorporeal femoral perfusion model for intravascular ultrasound, computed tomography and digital subtraction angiography. PLoS One 2023; 18:e0285810. [PMID: 37220113 DOI: 10.1371/journal.pone.0285810] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 05/02/2023] [Indexed: 05/25/2023] Open
Abstract
OBJECTIVES We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS). METHODS The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers. In all specimens, the common femoral and popliteal arteries were prepared, introducer sheaths inserted, and perfusion established by a peristaltic pump. Subsequently, we performed CTA and bilateral DSA in five cadavers and IVUS on both legs of four donors. Examination time without unintentional interruption was measured both with and without non-contrast planning CT. Percutaneous transluminal angioplasty and stenting was performed by two interventional radiologists on nine extremities (five donors) using a broad spectrum of different intravascular devices. RESULTS The perfusion of the upper leg arteries was successfully established in all fresh-frozen but not in the formalin-fixed cadaver. The experimental setup generated a stable circulation in each procedure (ten upper legs) for a period of more than six hours. Images acquired with CT, DSA and IVUS offered a realistic impression and enabled the sufficient visualization of all examined vessel segments. Arterial cannulating, percutaneous transluminal angioplasty as well as stent deployment were feasible in a way that is comparable to a vascular intervention in vivo. The perfusion model allowed for introduction and testing of previously not used devices. CONCLUSIONS The continuous femoral perfusion model can be established with moderate effort, works stable, and is utilizable for medical imaging of the peripheral arterial system using CTA, DSA and IVUS. Therefore, it appears suitable for research studies, developing skills in interventional procedures and testing of new or unfamiliar vascular devices.
Collapse
|
31
|
Patzer TS, Kunz AS, Huflage H, Luetkens KS, Conrads N, Gruschwitz P, Pannenbecker P, Ergün S, Bley TA, Grunz JP. Quantitative and qualitative image quality assessment in shoulder examinations with a first-generation photon-counting detector CT. Sci Rep 2023; 13:8226. [PMID: 37217553 DOI: 10.1038/s41598-023-35367-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 05/17/2023] [Indexed: 05/24/2023] Open
Abstract
Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDIvol = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as "non-UHR". Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ50 = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2-9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58-0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.
Collapse
|
32
|
Patzer TS, Kunz AS, Huflage H, Conrads N, Luetkens KS, Pannenbecker P, Paul MM, Ergün S, Bley TA, Grunz JP. Ultrahigh-Resolution Photon-Counting CT in Cadaveric Fracture Models: Spatial Frequency Is Not Everything. Diagnostics (Basel) 2023; 13:diagnostics13101677. [PMID: 37238160 DOI: 10.3390/diagnostics13101677] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/07/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDIvol 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1-3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732-0.848; p < 0.001) and fracture assessability (0.880; 0.842-0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0-3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise.
Collapse
|
33
|
Huflage H, Kunz AS, Hendel R, Kraft J, Weick S, Razinskas G, Sauer ST, Pennig L, Bley TA, Grunz JP. Obesity-Related Pitfalls of Virtual versus True Non-Contrast Imaging-An Intraindividual Comparison in 253 Oncologic Patients. Diagnostics (Basel) 2023; 13:diagnostics13091558. [PMID: 37174949 PMCID: PMC10177533 DOI: 10.3390/diagnostics13091558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/17/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
OBJECTIVES Dual-source dual-energy CT (DECT) facilitates reconstruction of virtual non-contrast images from contrast-enhanced scans within a limited field of view. This study evaluates the replacement of true non-contrast acquisition with virtual non-contrast reconstructions and investigates the limitations of dual-source DECT in obese patients. MATERIALS AND METHODS A total of 253 oncologic patients (153 women; age 64.5 ± 16.2 years; BMI 26.6 ± 5.1 kg/m2) received both multi-phase single-energy CT (SECT) and DECT in sequential staging examinations with a third-generation dual-source scanner. Patients were allocated to one of three BMI clusters: non-obese: <25 kg/m2 (n = 110), pre-obese: 25-29.9 kg/m2 (n = 73), and obese: >30 kg/m2 (n = 70). Radiation dose and image quality were compared for each scan. DECT examinations were evaluated regarding liver coverage within the dual-energy field of view. RESULTS While arterial contrast phases in DECT were associated with a higher CTDIvol than in SECT (11.1 vs. 8.1 mGy; p < 0.001), replacement of true with virtual non-contrast imaging resulted in a considerably lower overall dose-length product (312.6 vs. 475.3 mGy·cm; p < 0.001). The proportion of DLP variance predictable from patient BMI was substantial in DECT (R2 = 0.738) and SECT (R2 = 0.620); however, DLP of SECT showed a stronger increase in obese patients (p < 0.001). Incomplete coverage of the liver within the dual-energy field of view was most common in the obese subgroup (17.1%) compared with non-obese (0%) and pre-obese patients (4.1%). CONCLUSION DECT facilitates a 30.8% dose reduction over SECT in abdominal oncologic staging examinations. Employing dual-source scanner architecture, the risk for incomplete liver coverage increases in obese patients.
Collapse
|
34
|
Sauer ST, Christner SA, Kuhl PJ, Kunz AS, Huflage H, Luetkens KS, Schlaiß T, Bley TA, Grunz JP. Artificial-intelligence-enhanced synthetic thick slabs versus standard slices in digital breast tomosynthesis. Br J Radiol 2023; 96:20220967. [PMID: 36972100 PMCID: PMC10161903 DOI: 10.1259/bjr.20220967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
Objectives: Digital breast tomosynthesis (DBT)can provide additional information over mammography, albeit at the cost of prolonged reading time. Thisstudy retrospectively investigated the impact of reading enhanced synthetic 6 mm slabsinstead of standard 1 mm slices on interpretation time andreadersperformance in a diagnostic assessment centre. Methods: Three radiologists (R1-3; 6/4/2 years of breast imaging experience) reviewed 111 diagnostic DBT examinations. Two datasets were interpreted independently for each patient, with one set containing artificial-intelligence-enhanced synthetic 6 mm slabs with 3 mm overlap, while the other set comprised standard 1 mm slices. Blinded to histology and follow-up, readers noted individual BIRADS categoriesand diagnostic confidence while reading time was recorded. Among the 111 examinations, 70 findings were histopathologicallycorrelated including 56 malignancies. Results: No significant difference was found between BIRADS categories assigned based on6-mm vs 1 mm datasets (p ≥ 0.317). Diagnostic accuracy was comparable for 6 mm and 1 mm readings (R1: 87.0% vs 87.0%; R2: 86.1% vs 87.0%; R3: 80.0% vs 84.4%; p ≥ 0.125) with high interrater agreement (intraclass correlation coefficient 0.848 vs 0.865).Onereader reported higher confidence with 1 mm slices (R1: p = 0.033). Reading time was substantially shorter when interpreting 6 mm slabs compared to 1 mm slices (R1: 33.5 vs 46.2; R2: 49.1 vs 64.8; R3: 39.5 vs 67.2 sec; all p < 0.001). Conclusions: Artificial-intelligence-enhancedsynthetic 6 mm slabs allow for substantial interpretation time reduction in diagnostic DBT without a decrease inreader accuracy. Advances in knowledge: A simplified slab-only protocol instead of 1 mm slices may offset the higher reading time without a loss of diagnosis-relevant image information in first and second readings. Further evaluations are required regarding workflow implications,particularlyin screening settings.
Collapse
|
35
|
Kunz AS, Schmalzl J, Huflage H, Luetkens KS, Patzer TS, Kuhl PJ, Gruschwitz P, Petritsch B, Schmitt R, Bley TA, Grunz JP. Twin Robotic Gantry-Free Cone-Beam CT in Acute Elbow Trauma. Radiology 2023; 306:e221200. [PMID: 36346312 DOI: 10.1148/radiol.221200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.
Collapse
|
36
|
Conrads N, Grunz JP, Huflage H, Luetkens KS, Feldle P, Pennig L, Ergün S, Alexander Bley T, Petritsch B, Kunz AS. Ultrahigh-resolution computed tomography of the cervical spine without dose penalty employing a cadmium-telluride photon-counting detector. Eur J Radiol 2023; 160:110718. [PMID: 36731400 DOI: 10.1016/j.ejrad.2023.110718] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 01/18/2023] [Accepted: 01/25/2023] [Indexed: 01/28/2023]
Abstract
PURPOSE This cadaveric study compared image quality between a third-generation dual-source CT scanner with energy-integrating detector technology (EID) and a first-generation CT system employing a photon-counting detector (PCD) for the cervical spine in ultrahigh-resolution mode. METHODS The cervical spine of eight formalin-fixed full-body cadaveric specimens was scanned with both CT systems using 140 kVp scan protocols matched for CTDIvol (full-dose; low-dose; ultralow-dose; 10 mGy; 3 mGy; 1 mGy). Images were reconstructed with 1 mm slice thickness and 0.5 mm increment. Three radiologists rated overall subjective image quality based on an equidistant five-point scale with the intraclass correlation coefficient (ICC) calculated for assessment of interobserver reliability. Contrast-to-noise ratios were calculated individually for bone (CNRbone) and muscle tissue (CNRmuscle) to provide objective criteria of image analysis. RESULTS Subjective image quality, as well as CNRbone, and CNRmuscle were each superior for PCD-CT compared to EID-CT among dose-matched scan protocol pairs (all p < 0.05). Between full-dose EID-CT and low-dose PCD-CT, subjective image quality was equal (p = 0.903), while superior quantitative results regarding the latter were ascertained (both p < 0.001). Similarly, objective analysis determined higher CNRbone, and CNRmuscle in ultralow-dose PCD-CT compared to low-dose EID-CT (both p < 0.001), while readers considered the image quality of the respective studies comparable (p > 0.99). Interobserver reliability was good, denoted by an ICC of 0.861 (95 % confidence interval: 0.788 - 0.914; p < 0.001). CONCLUSIONS In cervical spine examinations, both subjective and objective image quality of PCD-CT were superior to EID-CT in comparison of scan protocols with corresponding dose levels, suggesting potential for significantly reducing the radiation exposure without compromising image quality.
Collapse
|
37
|
Huflage H, Grunz JP, Kunz AS, Patzer TS, Sauer ST, Christner SA, Petritsch B, Ergün S, Bley TA, Luetkens KS. Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip. Radiography (Lond) 2023; 29:44-49. [PMID: 36274316 DOI: 10.1016/j.radi.2022.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 09/14/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022]
Abstract
INTRODUCTION This study investigated the image quality of a new quantum iterative reconstruction algorithm (QIR) for high resolution photon-counting CT of the hip. METHODS Using a first-generation photon-counting CT scanner, five cadaveric specimens were examined with ultra-high-resolution protocols matched for radiation dose. Images were post-processed with a sharp convolution kernel and five different strength levels of iterative reconstruction (QIR 0 - QIR 4). Subjective image quality was rated independently by three radiologists on a five-point scale. Intraclass correlation coefficients (ICC) were computed for assessing interrater agreement. Objective image quality was evaluated by means of contrast-to-noise-ratios (CNR) in bone and muscle tissue. RESULTS For osseous tissue, subjective image quality was rated best for QIR 2 reformatting (median 5 [interquartile range 5-5]). Contrarily, for soft tissue, QIR 4 received the highest ratings among compared strength levels (3 [3-4]). Both ICCbone (0.805; 95% confidence interval 0.711-0.877; p < 0.001) and ICCmuscle (0.885; 0.824-0.929; p < 0.001) suggested good interrater agreement. CNR in bone and muscle tissue increased with ascending strength levels of iterative reconstruction with the highest results recorded for QIR 4 (CNRbone 29.43 ± 2.61; CNRmuscle 8.09 ± 0.77) and lowest results without QIR (CNRbone 3.90 ± 0.29; CNRmuscle 1.07 ± 0.07) (all p < 0.001). CONCLUSION Reconstructing photon-counting CT data with an intermediate QIR strength level appears optimal for assessment of osseous tissue, whereas soft tissue analysis benefitted from applying the highest strength level available. IMPLICATIONS FOR PRACTICE Quantum iterative reconstruction technique can enhance image quality by significantly reducing noise and improving CNR in ultra-high resolution CT imaging of the hip.
Collapse
|
38
|
Gruschwitz P, Petritsch B, Schmid A, Schmidt AMA, Grunz JP, Kuhl PJ, Heidenreich JF, Huflage H, Bley TA, Kosmala A. Noise-optimized virtual monoenergetic reconstructions of dual-energy CT angiographies improve assessability of the lower leg arterial segments in peripheral arterial occlusive disease. Radiography (Lond) 2023; 29:19-27. [PMID: 36209641 DOI: 10.1016/j.radi.2022.09.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/05/2022] [Accepted: 09/09/2022] [Indexed: 11/13/2022]
Abstract
INTRODUCTION The aim of this study was to evaluate the influence of a noise optimized virtual monoenergetic reconstruction algorithm (VMI+) on the image quality and assessability of dual energy (DE) computed tomography angiography (CTA) of the lower extremity runoff. METHODS A total of 118 lower extremity runoff CTA performed on a 3rd generation DE-CT scanner in 109 patients (54 females; 75.6 ± 9.5 years) were included in this retrospective study. Axial image stacks were reconstructed with a standard 120 kV setting and VMI+ of different keV levels. Objective image quality criteria (contrast attenuation, signal-to-noise [SNR] and contrast-to-noise ratio [CNR]) were measured. Two radiologists evaluated subjective image quality regarding intraluminal attenuation and image noise using a 5-point Likert scale. Diagnostic accuracy for significant stenosis (>75%) and vessel occlusion was assessed for 120 kV and 50 keV VMI+ images rated by two radiologists. In all patients, a digital subtraction angiography (DSA) rated by on board-certified radiologist served as the standard of reference. RESULTS Intraluminal attenuation was highest in 40/50 keV VMI+ while SNR were similar to 120 kV images. In subjective assessment, intraluminal contrast of 50 keV images was deemed superior compared to 120 kV despite higher image noise. Sensitivity, specificity, and accuracy for detection of a vessel occlusion were similar in 50 keV VMI+ compared to 120 kV (70%/92%/84%; 70%/91%/83%; p < 0.001) but 13 of 118 (11%) lower leg runoffs were only assessable with 50 keV VMI+. CONCLUSION VMI+ reconstructions improve assessability of DE-CTA by increased luminal attenuation with consistent image noise, also allowing the evaluation of lower leg arterial segments inassessable with standard reconstructions. IMPLICATIONS FOR PRACTICE Providing higher intraluminal attenuation and similar image noise compared with conventional reconstructions, 50 keV VMI+ may be appropriate for routine evaluation of DE-CTA.
Collapse
|
39
|
Jordan MC, Bröer D, Fischer C, Heilig P, Gilbert F, Hölscher-Doht S, Kalogirou C, Popp K, Grunz JP, Huflage H, Jakubietz RG, Ergün S, Meffert RH. Development and preclinical evaluation of a cable-clamp fixation device for a disrupted pubic symphysis. COMMUNICATIONS MEDICINE 2022; 2:164. [PMID: 36550296 PMCID: PMC9780275 DOI: 10.1038/s43856-022-00227-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 12/06/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage. METHODS To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility. RESULTS We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation. CONCLUSION We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Collapse
|
40
|
Grunz JP, Petritsch B, Luetkens KS, Kunz AS, Lennartz S, Ergün S, Bley TA, Huflage H. Ultra-Low-Dose Photon-Counting CT Imaging of the Paranasal Sinus With Tin Prefiltration: How Low Can We Go? Invest Radiol 2022; 57:728-733. [PMID: 35703452 DOI: 10.1097/rli.0000000000000887] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES In this study, we compared photon-counting detector computed tomography (PCD-CT) and energy-integrating detector computed tomography (EID-CT) for ultra-low-dose paranasal sinus examinations with employed tin prefiltration. The goal of our investigation was to define the most dose-effective scan protocols for diagnostic assessment of midface trauma, preoperative sinonasal anatomy, and acute rhinosinusitis. MATERIALS AND METHODS Five cadaveric heads were examined with the standard-resolution scan mode of both CT systems using a tube potential of 100 kV and tin prefiltration for 7 dose-equivalent scan protocols (CTDI vol = 4.16-0.15 mGy) and 2 additional ultra-low-dose protocols exclusively feasible on the PCD-CT scanner (0.10 and 0.08 mGy). After applying comparable iterative reconstruction algorithms, image quality was subjectively assessed by 4 radiologists. The intraclass correlation coefficient was calculated to estimate the agreement among readers. Image noise was quantified in standardized regions of interest to establish an additional quantitative criterion of image quality. RESULTS The most dose-effective scan protocols for diagnostic imaging of midface trauma (PCD-CT: 1.24 mGy; EID-CT: 2.05 mGy), preoperative sinonasal anatomy (PCD-CT: 0.20 mGy; EID-CT: 0.40 mGy), and acute rhinosinusitis (PCD-CT: 0.08 mGy; EID-CT: 0.15 mGy) required less radiation exposure on the PCD-CT system ( P < 0.050). Despite higher image noise, ultra-low-dose PCD-CT studies (0.08 and 0.10 mGy) were considered suitable for inflammation-focused imaging, offering lower-dose penalties than EID-CT studies. Interobserver reliability for subjective image quality was excellent (intraclass correlation coefficient, 0.90; 95% confidence interval, 0.88-0.93; P < 0.001). CONCLUSIONS In paranasal sinus imaging with tin prefiltration, the PCD-CT allowed for superior image quality compared with high-end EID-CT. Assessment of paranasal sinuses with an ultra-low radiation exposure of 0.08 mGy was deemed adequate, suggesting substantial dose reduction potential for clinical routine, for example, in the diagnostic workup of patients with rhinosinusitis.
Collapse
|
41
|
Kunz AS, Patzer TS, Grunz JP, Luetkens KS, Hartung V, Hendel R, Fieber T, Genest F, Ergün S, Bley TA, Huflage H. Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system. Sci Rep 2022; 12:15549. [PMID: 36114270 PMCID: PMC9481547 DOI: 10.1038/s41598-022-19978-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 09/07/2022] [Indexed: 11/23/2022] Open
Abstract
Cone-beam computed tomography (CBCT) has been shown to be a powerful tool for 3D imaging of the appendicular skeleton, allowing for detailed visualization of bone microarchitecture. This study was designed to compare artifacts in the presence of osteosynthetic implants between CBCT and multidetector computed tomography (MDCT) in cadaveric wrist scans. A total of 32 scan protocols with varying tube potential and current were employed: both conventional CBCT and MDCT studies were included with tube voltage ranging from 60 to 140 kVp as well as additional MDCT protocols with dedicated spectral shaping via tin prefiltration. Irrespective of scanner type, all examinations were conducted in ultra-high-resolution (UHR) scan mode. For reconstruction of UHR-CBCT scans an additional iterative metal artifact reduction algorithm was employed, an image correction tool which cannot be used in combination with UHR-MDCT. To compare applied radiation doses between both scanners, the volume computed tomography dose index for a 16 cm phantom (CTDIvol) was evaluated. Images were assessed regarding subjective and objective image quality. Without automatic tube current modulation or tube potential control, radiation doses ranged between 1.3 mGy (with 70 kVp and 50.0 effective mAs) and 75.2 mGy (with 140 kVp and 383.0 effective mAs) in UHR-MDCT. Using the pulsed image acquisition method of the CBCT scanner, CTDIvol ranged between 2.3 mGy (with 60 kVp and 0.6 mean mAs per pulse) and 61.0 mGy (with 133 kVp and 2.5 mean mAs per pulse). In essence, all UHR-CBCT protocols employing a tube potential of 80 kVp or more were found to provide superior overall image quality and artifact reduction compared to UHR-MDCT (all p < .050). Interrater reliability of seven radiologists regarding image quality was substantial for tissue assessment and moderate for artifact assessment with Fleiss kappa of 0.652 (95% confidence interval 0.618-0.686; p < 0.001) and 0.570 (95% confidence interval 0.535-0.606; p < 0.001), respectively. Our results demonstrate that the UHR-CBCT scan mode of a twin robotic X-ray system facilitates excellent visualization of the appendicular skeleton in the presence of metal implants. Achievable image quality and artifact reduction are superior to dose-comparable UHR-MDCT and even MDCT protocols employing spectral shaping with tin prefiltration do not achieve the same level of artifact reduction in adjacent soft tissue.
Collapse
|
42
|
Luetkens KS, Grunz JP, Paul MM, Huflage H, Conrads N, Patzer TS, Gruschwitz P, Ergün S, Bley TA, Kunz AS. One-stop-shop CT arthrography of the wrist without subject repositioning by means of gantry-free cone-beam CT. Sci Rep 2022; 12:14422. [PMID: 36002544 PMCID: PMC9402709 DOI: 10.1038/s41598-022-18395-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 08/10/2022] [Indexed: 11/16/2022] Open
Abstract
Modern cone-beam CT systems are capable of ultra-high-resolution 3D imaging in addition to conventional radiography and fluoroscopy. The combination of various imaging functions in a multi-use setup is particularly appealing for musculoskeletal interventions, such as CBCT arthrography (CBCTA). With this study, we aimed to investigate the feasibility of CBCTA of the wrist in a “one-stop-shop” approach with a gantry-free twin robotic scanner that does not require repositioning of subjects. Additionally, the image quality of CBCTA was compared to subsequent arthrograms on a high-end multidetector CT (MDCTA). Fourteen cadaveric wrists received CBCTA with four acquisition protocols. Specimens were then transferred to the CT suite for additional MDCTA. Dose indices ranged between 14.3 mGy (120 kVp/100 effective mAs; full-dose) and 1.0 mGy (70 kVp/41 effective mAs; ultra-low-dose) for MDCTA and between 17.4 mGy (80 kVp/2.5 mAs per pulse; full-dose) and 1.2 mGy (60 kVp/0.5 mAs per pulse; ultra-low-dose) for CBCTA. Subjective image quality assessment for bone, cartilage and ligamentous tissue was performed by seven radiologists. The interrater reliability was assessed by calculation of the intraclass correlation coefficient (ICC) based on a two-way random effects model. Overall image quality of most CBCTA was deemed suitable for diagnostic use in contrast to a considerable amount of non-diagnostic MDCTA examinations (38.8%). The depiction of bone, cartilage and ligaments in MDCTA with any form of dose reduction was inferior to any CBCTA scan with at least 0.6 mAs per pulse (all p < 0.001). Full-dose MDCTA and low-dose CBCTA were of equal quality for bone tissue visualization (p = 0.326), whereas CBCTA allowed for better depiction of ligaments and cartilage (both p < 0.001), despite merely one third of radiation exposure (MDCTA–14.3 mGy vs. CBCTA–4.5 mGy). Moderate to good interrater reliability was ascertained for the assessment all tissues (ICC 0.689–0.756). Overall median examination time for CBCTA was 5.4 min (4.8–7.2 min). This work demonstrates that substantial dose reduction can be achieved in CT arthrography of the wrist while maintaining diagnostic image quality by employing the cone-beam CT mode of a twin robotic X-ray system. The ability of the multi-use X-ray system to switch between fluoroscopy mode and 3D imaging allows for “one-stop-shop” CBCTA in minimal examination time without the need for repositioning.
Collapse
|
43
|
Luetkens K, Gassenmaier T, Kunz A, Gietzen HC, Huflage H, Bley AT, Schmitt R, Grunz PJ. Stellenwert der intravenös kontrastverstärkten MRT für die Diagnose von zentralen und peripheren TFCC-Läsionen. ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
44
|
Huflage H, Luetkens K, Kunz SA, Görtz L, Pennig L, Conrads N, Bley AT, Schmitt R, Grunz PJ. Die radiäre Rekonstruktion isotroper 3D-Sequenzen verbessert die diagnostische Genauigkeit für periphere TFCC-Verletzungen in der MR-Arthrographie des Handgelenks. ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
45
|
Kunz A, Luetkens K, Huflage H, Bley T, Gassenmaier T, Grunz PJ. Zinn-Filter-Einsatz in der Kegelstrahl-CT-Bildgebung des Extremitätenskeletts mit einem multifunktionalen Roboter-Röntgensystem. ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
46
|
Gietzen C, Kunz A, Luetkens K, Huflage H, Christopoulos G, van Shonhooven J, Bley T, Schmitt R, Grunz PJ. Evaluation of prestyloid recess morphology and ulnar-sided contrast leakage in CT arthrography of the wrist. ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
47
|
Conrads N, Grunz JP, Huflage H, Luetkens KS, Feldle P, Grunz K, Köhler S, Westermaier T. Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine. Arch Orthop Trauma Surg 2022; 143:3007-3013. [PMID: 35794344 DOI: 10.1007/s00402-022-04514-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 06/08/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. MATERIALS AND METHODS Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. RESULTS Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. CONCLUSIONS Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
Collapse
|
48
|
Huflage H, Grunz JP, Hackenbroch C, Halt D, Luetkens KS, Alfred Schmidt AM, Patzer TS, Ergün S, Bley TA, Kunz AS. Metal artefact reduction in low-dose computed tomography: Benefits of tin prefiltration versus postprocessing of dual-energy datasets over conventional CT imaging. Radiography (Lond) 2022; 28:690-696. [PMID: 35728278 DOI: 10.1016/j.radi.2022.05.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 05/01/2022] [Accepted: 05/30/2022] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The purpose of this study was to determine the potential for metal artefact reduction in low-dose multidetector CT as these pose a frequent challenge in clinical routine. Investigations focused on whether spectral shaping via tin prefiltration, virtual monoenergetic imaging or virtual blend imaging (VBI) offers superior image quality in comparison with conventional CT imaging. METHODS Using a third-generation dual-source CT scanner, two cadaveric specimens with different metal implants (dental, cervical spine, hip, knee) were examined with acquisition protocols matched for radiation dose with regards to tube voltage and current. In order to allow for precise comparison, and due to the relatively short scan lengths, automatic tube current modulation was disabled. Specifically, the following scan protocals were examined: conventional CT protocols (100/120 kVp), tin prefiltration (Sn 100/Sn 150 kVp), VBI and virtual monoenergetic imaging (VME 100/120/150 keV). Mean attenuation and image noise were measured in hyperdense and hypodense artefacts, in artefact-impaired and artefact-free soft tissue. Subjective image quality was rated independently by three radiologists. RESULTS Objectively, Sn 150 kVp allowed for the best reduction of hyperdense streak artefacts (p < 0.001), while VME 150 keV and Sn 150 kVp protocols facilitated equally good reduction of hypodense artefacts (p = 0.173). Artefact-impaired soft tissue attenuation was lowest in Sn 150 kVp protocols (p ≤ 0.011), whereas all VME showed significantly less image noise compared to conventional or tin-filtered protocols (p ≤ 0.001). Subjective assessment favoured Sn 150 kVp regarding hyperdense streak artefacts and delineation of cortical bone (p ≤ 0.005). The intraclass correlation coefficient was 0.776 (95% confidence interval: 0.712-0.831; p < 0.001) indicating good interrater reliability. CONCLUSION In the presence of metal implants in our cadaveric study, tin prefiltration with 150 kVp offers superior artefact reduction for low-dose CT imaging of osseous tissue compared with virtual monoenergetic images of dual-energy datasets. The delineation of cortical boundaries seems to benefit particularly from spectral shaping. IMPLICATIONS FOR PRACTICE Low-dose CT imaging of osseous tissue in combination with tin prefiltration allows for superior metal artefact reduction when compared to virtual monoenergetic images of dual-energy datasets. Employing this technique ought to be considered in daily routine when metal implants are present within the scan volume as findings suggest it allows for radiation dose reduction and facilitates diagnosis relevant to further treatment.
Collapse
|
49
|
Gietzen CH, Kunz AS, Luetkens KS, Huflage H, Christopoulos G, van Schoonhoven J, Bley TA, Schmitt R, Grunz JP. Evaluation of prestyloid recess morphology and ulnar-sided contrast leakage in CT arthrography of the wrist. BMC Musculoskelet Disord 2022; 23:284. [PMID: 35331212 PMCID: PMC8944076 DOI: 10.1186/s12891-022-05241-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 03/17/2022] [Indexed: 11/20/2022] Open
Abstract
Background In wrist arthrograms, aberrant contrast material is frequently seen extending into the soft tissue adjacent to the ulnar styloid process. Since the prestyloid recess can mimic contrast leakage in CT arthrography, this study aims to provide a detailed analysis of its morphologic variability, while investigating whether actual ulnar-sided leakage is associated with injuries of the triangular fibrocartilage complex (TFCC). Methods Eighty-six patients with positive wrist trauma history underwent multi-compartment CT arthrography (40 women, median age 44.5 years). Studies were reviewed by two board-certified radiologists, who documented the morphology of the prestyloid recess regarding size, opening type, shape and position, as well as the presence or absence of ulnar-sided contrast leakage. Correlations between leakage and the presence of TFCC injuries were assessed using the mean square contingency coefficient (rɸ). Results The most common configuration of the prestyloid recess included a narrow opening (73.26%; width 2.26 ± 1.43 mm), saccular shape (66.28%), and palmar position compared to the styloid process (55.81%). Its mean length and anterior–posterior diameter were 6.89 ± 2.36 and 5.05 ± 1.97 mm, respectively. Ulnar-sided contrast leakage was reported in 29 patients (33.72%) with a mean extent of 12.30 ± 5.31 mm. Leakage occurred more often in patients with ulnar-sided TFCC injuries (rɸ = 0.480; p < 0.001), whereas no association was found for lesions of the central articular disc (rɸ = 0.172; p = 0.111). Conclusions Since ulnar-sided contrast leakage is more common in patients with peripheral TFCC injuries, distinction between an atypical configuration of the prestyloid recess and actual leakage is important in CT arthrography of the wrist.
Collapse
|
50
|
Huflage H, Fieber T, Färber C, Knarr J, Veldhoen S, Jordan MC, Gilbert F, Bley TA, Meffert RH, Grunz JP, Schmalzl J. Interobserver reliability of scapula fracture classifications in intra- and extra-articular injury patterns. BMC Musculoskelet Disord 2022; 23:189. [PMID: 35232415 PMCID: PMC8886840 DOI: 10.1186/s12891-022-05146-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 02/22/2022] [Indexed: 11/10/2022] Open
Abstract
Background Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice. Methods Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers. Results In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676–0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525–0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771–0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692–0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912). Conclusions The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.
Collapse
|