26
|
Lee HW, Kim YG, Yoo JY, Yoon JW, Yang JM, Lim H, Nam CH, Sung JH, Lee SK. Spectral shaping of an OPCPA preamplifier for a sub-20-fs multi-PW laser. OPTICS EXPRESS 2018; 26:24775-24783. [PMID: 30469589 DOI: 10.1364/oe.26.024775] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 08/31/2018] [Indexed: 06/09/2023]
Abstract
We developed an OPCPA preamplifier with an actively shaped output spectrum to obtain a sub-20-fs-duration pulse for a 4-PW laser. The active spectral shaping was facilitated by controlling the temporal profile of a pump pulse in the OPCPA preamplifier. By optimizing the output spectrum of the OPCPA to compensate for the gain-depletion effect in the 4-PW laser, a final laser pulse with a broad spectrum of 101-nm in width (FWHM), resulting in a short pulse duration of 17 fs, was achieved.
Collapse
|
27
|
Kim D, Yang PS, Jang E, Yu HT, Kim TH, Uhm JS, Kim JY, Sung JH, Pak HN, Lee MH, Joung B, Lip GYH. P1195Current and future incidence and prevalence of atrial fibrillation in korea. Europace 2018. [DOI: 10.1093/europace/euy015.677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
28
|
Kim D, Yang PS, Jang E, Yu HT, Kim TH, Uhm JS, Kim JY, Pak HN, Lee MH, Sung JH, Joung B, Lip GYH. P1196Increasing trends in hospital-care burden of atrial fibrillation in korea, 2006 through 2015: implications for healthcare planning. Europace 2018. [DOI: 10.1093/europace/euy015.678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
29
|
Yu HT, Yang PS, Hwang J, Ryu S, Jang E, Kim TH, Uhm JS, Sung JH, Kim JY, Pak HN, Lee MH, Joung B, Lip GYH. P378Influence of reimbursement of non-vitamin K antagonist oral anticoagulants on overall prescription rates of oral anticoagulation: A nationwide study using the Korean National Health Insurance Data. Europace 2018. [DOI: 10.1093/europace/euy015.189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
30
|
Lim YM, Yang PS, Jang ES, Yu HT, Kim TH, Uhm JS, Sung JH, Kim JY, Pak HN, Lee MH, Joung B, Lip GYH. 1009Body mass index variability and long-term risk of new-onset atrial fibrillation in the general population: a korean nationwide cohort study. Europace 2018. [DOI: 10.1093/europace/euy015.558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
31
|
Kim HT, Pathak VB, Hong Pae K, Lifschitz A, Sylla F, Shin JH, Hojbota C, Lee SK, Sung JH, Lee HW, Guillaume E, Thaury C, Nakajima K, Vieira J, Silva LO, Malka V, Nam CH. Stable multi-GeV electron accelerator driven by waveform-controlled PW laser pulses. Sci Rep 2017; 7:10203. [PMID: 28860579 PMCID: PMC5579019 DOI: 10.1038/s41598-017-09267-1] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 07/18/2017] [Indexed: 12/04/2022] Open
Abstract
The achievable energy and the stability of accelerated electron beams have been the most critical issues in laser wakefield acceleration. As laser propagation, plasma wave formation and electron acceleration are highly nonlinear processes, the laser wakefield acceleration (LWFA) is extremely sensitive to initial experimental conditions. We propose a simple and elegant waveform control method for the LWFA process to enhance the performance of a laser electron accelerator by applying a fully optical and programmable technique to control the chirp of PW laser pulses. We found sensitive dependence of energy and stability of electron beams on the spectral phase of laser pulses and obtained stable 2-GeV electron beams from a 1-cm gas cell of helium. The waveform control technique for LWFA would prompt practical applications of centimeter-scale GeV-electron accelerators to a compact radiation sources in the x-ray and γ-ray regions.
Collapse
|
32
|
Krivit W, Sung JH, Shapiro EG, Lockman LA. Microglia: The Effector Cell for Reconstitution of the Central Nervous System following Bone Marrow Transplantation for Lysosomal and Peroxisomal Storage Diseases. Cell Transplant 2017; 4:385-92. [PMID: 7582569 DOI: 10.1177/096368979500400409] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Treatment and potential cure of lysosomal and peroxisomal diseases, heretofore considered fatal, has become a reality during the past decade. Bone marrow transplantation, (BMT), has provided a method for replacement of the disease-causing enzyme deficiency. Cells derived from the donor marrow continue to provide enzyme indefinitely. Several scores of patients with diseases as diverse as metachromatic leukodystrophy, adrenoleukodystrophy, globoid cell leukodystrophy, Hurler syndrome (MPS I-H), Maroteaux-Lamy (MPS VI) Gaucher disease, and fucosidosis have been successfully treated following long-term engraftment. Central nervous system (CNS) manifestations are also prevented or ameliorated in animal models of these diseases following engraftment from normal donors. The microglial cell system has been considered to be the most likely vehicle for enzyme activity following bone marrow engraftment. Microglia in the mature animal or human are derived from the newly engrafted bone marrow. Graft-v-host disease activation of the microglia is also of importance. This article will summarize some of the pertinent literature relative to the role of microglia in such transplant processes.
Collapse
|
33
|
Sung JH, Lee HW, Yoo JY, Yoon JW, Lee CW, Yang JM, Son YJ, Jang YH, Lee SK, Nam CH. 4.2 PW, 20 fs Ti:sapphire laser at 0.1 Hz. OPTICS LETTERS 2017; 42:2058-2061. [PMID: 28569844 DOI: 10.1364/ol.42.002058] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 04/20/2017] [Indexed: 06/07/2023]
Abstract
We demonstrated the generation of 4.2 PW laser pulses at 0.1 Hz from a chirped-pulse amplification Ti:sapphire laser. The cross-polarized wave generation and the optical parametric chirped-pulse amplification stages were installed for the prevention of the gain narrowing and for the compensation of the spectral narrowing in the amplifiers, obtaining the spectral width of amplified laser pulses of 84 nm (FWHM), and enhancing the temporal contrast. The amplified laser pulses of 112 J after the final booster amplifier were compressed to the pulses with 83 J at 19.4 fs with a shot-to-shot energy stability of 1.5% (RMS). This 4.2 PW laser will be a workhorse for exploring high field science.
Collapse
|
34
|
Ter-Avetisyan S, Andreev A, Platonov K, Sung JH, Lee SK, Lee HW, Yoo JY, Singh PK, Ahmed H, Scullion C, Kakolee KF, Jeong TW, Hadjisolomou P, Borghesi M. Surface modulation and back reflection from foil targets irradiated by a Petawatt femtosecond laser pulse at oblique incidence. OPTICS EXPRESS 2016; 24:28104-28112. [PMID: 27906375 DOI: 10.1364/oe.24.028104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A significant level of back reflected laser energy was measured during the interaction of ultra-short, high contrast PW laser pulses with solid targets at 30° incidence. 2D PIC simulations carried out for the experimental conditions show that at the laser-target interface a dynamic regular structure is generated during the interaction, which acts as a grating (quasi-grating) and reflects back a significant amount of incident laser energy. With increasing laser intensity above 1018 W/cm2 the back reflected fraction increases due to the growth of the surface modulation to larger amplitudes. Above 1020 W/cm2 this increase results in the partial destruction of the quasi-grating structure and, hence, in the saturation of the back reflection efficiency. The PIC simulation results are in good agreement with the experimental findings, and, additionally, demonstrate that in presence of a small amount of pre-plasma this regular structure will be smeared out and the back reflection reduced.
Collapse
|
35
|
Jeon KS, Sung JH, Lee MW, Song HY, Shin HY, Park WH, Jang YI, Kang MG, Choi YH, Lee JS, Ko DH, Ryu HY. A Study of Piezoelectric Field Related Strain Difference in GaN-Based Blue Light-Emitting Diodes Grown on Silicon(111) and Sapphire Substrates. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2016; 16:1798-1801. [PMID: 27433673 DOI: 10.1166/jnn.2016.11939] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We investigate the strain difference in InGaN/GaN multiple quantum wells of blue light-emitting diode (LED) structures grown on silicon(1 11) and c-plane sapphire substrates by comparing the strength of piezo-electric fields in MQWs. The piezo-electric fields for two LED samples grown on silicon and sapphire substrates are measured by using the reverse-bias electro-reflectance (ER) spectroscopy. The flat-band voltage is obtained by measuring the applied reverse bias voltage that induces a phase inversion in the ER spectra, which is used to calculate the strength of piezo-electric fields. The piezo-electric field is determined to be 1.36 MV/cm for the LED on silicon substrate and 1.83 MV/cm for the LED on sapphire substrate. The ER measurement results indicate that the strain-induced piezo-electric field is greatly reduced in the LED grown on silicon substrates consistent with previous strain measurement results by micro-Raman spectroscopy and high-resolution transmission electron microscopy.
Collapse
|
36
|
Jeon JH, Nakajima K, Kim HT, Rhee YJ, Pathak VB, Cho MH, Shin JH, Yoo BJ, Hojbota C, Jo SH, Shin KW, Sung JH, Lee SK, Cho BI, Choi IW, Nam CH. A broadband gamma-ray spectrometry using novel unfolding algorithms for characterization of laser wakefield-generated betatron radiation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:123116. [PMID: 26724015 DOI: 10.1063/1.4939014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a high-flux, broadband gamma-ray spectrometry capable of characterizing the betatron radiation spectrum over the photon energy range from 10 keV to 20 MeV with respect to the peak photon energy, spectral bandwidth, and unique discrimination from background radiations, using a differential filtering spectrometer and the unfolding procedure based on the Monte Carlo code GEANT4. These properties are experimentally verified by measuring betatron radiation from a cm-scale laser wakefield accelerator (LWFA) driven by a 1-PW laser, using a differential filtering spectrometer consisting of a 15-filter and image plate stack. The gamma-ray spectra were derived by unfolding the photostimulated luminescence (PSL) values recorded on the image plates, using the spectrometer response matrix modeled with the Monte Carlo code GEANT4. The accuracy of unfolded betatron radiation spectra was assessed by unfolding the test PSL data simulated with GEANT4, showing an ambiguity of less than 20% and clear discrimination from the background radiation with less than 10%. The spectral analysis of betatron radiation from laser wakefield-accelerated electron beams with energies up to 3 GeV revealed radiation spectra characterized by synchrotron radiation with the critical photon energy up to 7 MeV. The gamma-ray spectrometer and unfolding method presented here facilitate an in-depth understanding of betatron radiation from LWFA process and a novel radiation source of high-quality photon beams in the MeV regime.
Collapse
|
37
|
Jeon KS, Sung JH, Lee MW, Song HY, Lee EA, Kim SO, Choi HJ, Shin HY, Park WH, Jang YI, Kang MG, Choi YH, Lee JS, Ko DH, Ryu HY. Comparison of Strain in GaN-Based Blue Light-Emitting Diode Grown on Silicon(111) and Sapphire Substrates. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2015; 15:5264-5266. [PMID: 26373120 DOI: 10.1166/jnn.2015.10408] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We compare the strain states and device performances of GaN-based blue light-emitting diodes (LEDs) grown on Si(111) and sapphire substrates. The strain characteristics are investigated using micro-Raman spectroscopy and high-resolution transmission electron microscopy. These analyses reveal that GaN layer grown on Si has a residual tensile strain in contrast to a compressive strain for GaN on sapphire, and quantum wells (QWs) on GaN/Si experience reduced lattice mismatch than those of GaN/sapphire. When external quantum efficiencies of LED on sapphire and Si substrates are compared, the LED on Si shows better efficiency droop characteristics and this is attributed to a decrease in piezo-electric field strength in InGaN/GaN layers owing to reduced lattice mismatch.
Collapse
|
38
|
Yun H, Lee KM, Sung JH, Kim KT, Kim HT, Nam CH. Resolving multiple molecular orbitals using two-dimensional high-harmonic spectroscopy. PHYSICAL REVIEW LETTERS 2015; 114:153901. [PMID: 25933315 DOI: 10.1103/physrevlett.114.153901] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Indexed: 06/04/2023]
Abstract
High-harmonic radiation emitted from molecules in a strong laser field contains information on molecular structure and dynamics. When multiple molecular orbitals participate in high-harmonic generation, resolving the contribution of each orbital is crucial for understanding molecular dynamics and for extending high-harmonic spectroscopy to more complicated molecules. We show that two-dimensional high-harmonic spectroscopy can resolve high-harmonic radiation emitted from the two highest-occupied molecular orbitals, HOMO and HOMO-1, of aligned molecules. By the application of an orthogonally polarized two-color laser field that consists of the fundamental and its second-harmonic fields to aligned CO2 molecules, the characteristics attributed to the two orbitals are found to be separately imprinted in odd and even harmonics. Two-dimensional high-harmonic spectroscopy may open a new route to investigate ultrafast molecular dynamics during chemical processes.
Collapse
|
39
|
Park SH, Sung JH, Kim EJ, Chung N. Berberine induces apoptosis via ROS generation in PANC-1 and MIA-PaCa2 pancreatic cell lines. ACTA ACUST UNITED AC 2014; 48:111-9. [PMID: 25517919 PMCID: PMC4321216 DOI: 10.1590/1414-431x20144293] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Accepted: 09/26/2014] [Indexed: 02/08/2023]
Abstract
Pancreatic cancer is the fourth leading cause of cancer death. Gemcitabine is widely
used as a chemotherapeutic agent for the treatment of pancreatic cancer, but the
prognosis is still poor. Berberine, an isoquinoline alkaloid extracted from a variety
of natural herbs, possesses a variety of pharmacological properties including
anticancer effects. In this study, we investigated the anticancer effects of
berberine and compared its use with that of gemcitabine in the pancreatic cancer cell
lines PANC-1 and MIA-PaCa2. Berberine inhibited cell growth in a dose-dependent
manner by inducing cell cycle arrest and apoptosis. After berberine treatment, the G1
phase of PANC-1 cells increased by 10% compared to control cells, and the G1 phase of
MIA-PaCa2 cells was increased by 2%. Whereas gemcitabine exerts antiproliferation
effects through S-phase arrest, our results showed that berberine inhibited
proliferation by inducing G1-phase arrest. Berberine-induced apoptosis of PANC-1 and
MIA-PaCa2 cells increased by 7 and 2% compared to control cells, respectively.
Notably, berberine had a greater apoptotic effect in PANC-1 cells than gemcitabine.
Upon treatment of PANC-1 and MIA-PaCa2 with berberine at a half-maximal inhibitory
concentration (IC50), apoptosis was induced by a mechanism that involved
the production of reactive oxygen species (ROS) rather than caspase 3/7 activation.
Our findings showed that berberine had anti-cancer effects and may be an effective
drug for pancreatic cancer chemotherapy.
Collapse
|
40
|
Jang DK, Lee KS, Rha HK, Huh PW, Yang JH, Park IS, Ahn JG, Sung JH, Han YM. Clinical and angiographic features and stroke types in adult moyamoya disease. AJNR Am J Neuroradiol 2014; 35:1124-31. [PMID: 24384121 DOI: 10.3174/ajnr.a3819] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE This study was conducted to elucidate the association between clinical and angiographic characteristics and stroke types in adult Moyamoya disease that has been rarely evaluated. MATERIALS AND METHODS We analyzed the clinical and radiologic data obtained from a retrospective adult Moyamoya disease cohort with acute strokes, which were classified into 7 categories: large-artery infarct, hemodynamic infarct, perforator infarct, deep intracerebral hemorrhage, lobar intracerebral hemorrhage, intraventricular hemorrhage, and SAH. With conventional angiography, which was performed in the hemispheres with acute strokes, the Suzuki angiographic stage, intracranial aneurysm, major artery occlusion, and collateral vessel development were confirmed within 1 month of stroke onset. RESULTS This study included 79 patients with acute ischemic stroke and 96 patients with acute hemorrhagic stroke. The angiographic stage had a strong tendency to be more advanced in the hemorrhagic than the ischemic patients (P = .061). Intracranial aneurysms were more frequently found in the hemorrhagic than ischemic or control hemispheres (P = .002). Occlusions of the anterior cerebral artery and development of fetal-type posterior cerebral artery were more frequently observed in the hemorrhagic than the ischemic (P = .001 and .01, respectively) or control hemispheres (P = .011 and .013, respectively). MCA occlusion (P = .039) and collateral flow development, including the ethmoidal Moyamoya vessels (P = .036) and transdural anastomosis of the external carotid artery (P = .022), occurred more often in the hemorrhagic than the ischemic hemispheres. Anterior cerebral artery occlusion occurred more frequently in patients with deep intracerebral hemorrhage or intraventricular hemorrhage than with lobar intracerebral hemorrhage (P = .009). CONCLUSIONS In adult Moyamoya disease, major artery occlusion and collateral compensation occurred more often in the hemorrhagic than in the ischemic hemispheres. Thus, anterior cerebral artery occlusion with or without MCA occlusion and intracranial aneurysms may be the main contributing factors to hemorrhagic stroke in adult patients with Moyamoya disease.
Collapse
|
41
|
Kim HT, Pae KH, Cha HJ, Kim IJ, Yu TJ, Sung JH, Lee SK, Jeong TM, Lee J. Enhancement of electron energy to the multi-GeV regime by a dual-stage laser-wakefield accelerator pumped by petawatt laser pulses. PHYSICAL REVIEW LETTERS 2013; 111:165002. [PMID: 24182273 DOI: 10.1103/physrevlett.111.165002] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Indexed: 06/02/2023]
Abstract
Laser-wakefield acceleration offers the promise of a compact electron accelerator for generating a multi-GeV electron beam using the huge field gradient induced by an intense laser pulse, compared to conventional rf accelerators. However, the energy and quality of the electron beam from the laser-wakefield accelerator have been limited by the power of the driving laser pulses and interaction properties in the target medium. Recent progress in laser technology has resulted in the realization of a petawatt (PW) femtosecond laser, which offers new capabilities for research on laser-wakefield acceleration. Here, we present a significant increase in laser-driven electron energy to the multi-GeV level by utilizing a 30-fs, 1-PW laser system. In particular, a dual-stage laser-wakefield acceleration scheme (injector and accelerator scheme) was applied to boost electron energies to over 3 GeV with a single PW laser pulse. Three-dimensional particle-in-cell simulations corroborate the multi-GeV electron generation from the dual-stage laser-wakefield accelerator driven by PW laser pulses.
Collapse
|
42
|
Kim IJ, Pae KH, Kim CM, Kim HT, Sung JH, Lee SK, Yu TJ, Choi IW, Lee CL, Nam KH, Nickles PV, Jeong TM, Lee J. Transition of proton energy scaling using an ultrathin target irradiated by linearly polarized femtosecond laser pulses. PHYSICAL REVIEW LETTERS 2013; 111:165003. [PMID: 24182274 DOI: 10.1103/physrevlett.111.165003] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2013] [Indexed: 06/02/2023]
Abstract
Particle acceleration using ultraintense, ultrashort laser pulses is one of the most attractive topics in relativistic laser-plasma research. We report proton and/or ion acceleration in the intensity range of 5×10(19) to 3.3×10(20) W/cm2 by irradiating linearly polarized, 30-fs laser pulses on 10-to 100-nm-thick polymer targets. The proton energy scaling with respect to the intensity and target thickness is examined, and a maximum proton energy of 45 MeV is obtained when a 10-nm-thick target is irradiated by a laser intensity of 3.3×10(20) W/cm2. The proton acceleration is explained by a hybrid acceleration mechanism including target normal sheath acceleration, radiation pressure acceleration, and Coulomb explosion assisted-free expansion. The transition of proton energy scaling from I(1/2) to I is observed as a consequence of the hybrid acceleration mechanism. The experimental results are supported by two- and three-dimensional particle-in-cell simulations.
Collapse
|
43
|
Margarone D, Klimo O, Kim IJ, Prokůpek J, Limpouch J, Jeong TM, Mocek T, Pšikal J, Kim HT, Proška J, Nam KH, Stolcová L, Choi IW, Lee SK, Sung JH, Yu TJ, Korn G. Laser-driven proton acceleration enhancement by nanostructured foils. PHYSICAL REVIEW LETTERS 2012; 109:234801. [PMID: 23368211 DOI: 10.1103/physrevlett.109.234801] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2012] [Indexed: 06/01/2023]
Abstract
Nanostructured thin plastic foils have been used to enhance the mechanism of laser-driven proton beam acceleration. In particular, the presence of a monolayer of polystyrene nanospheres on the target front side has drastically enhanced the absorption of the incident 100 TW laser beam, leading to a consequent increase in the maximum proton energy and beam charge. The cutoff energy increased by about 60% for the optimal spheres' diameter of 535 nm in comparison to the planar foil. The total number of protons with energies higher than 1 MeV was increased approximately 5 times. To our knowledge this is the first experimental demonstration of such advanced target geometry. Experimental results are interpreted and discussed by means of 2(1/2)-dimensional particle-in-cell simulations.
Collapse
|
44
|
Ihn YK, Kim SH, Sung JH, Kim TG. The efficacy of endovascular treatment of ruptured blood blister-like aneurysms using stent-assisted coil embolization. Interv Neuroradiol 2012; 18:432-41. [PMID: 23217638 DOI: 10.1177/159101991201800409] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2012] [Accepted: 06/06/2012] [Indexed: 11/15/2022] Open
Abstract
We report our experience with endovascular treatment and follow-up results of a ruptured blood blister-like aneurysm (BBA) in the supraclinoid internal carotid artery. We performed a retrospective review of ruptured blood blister-like aneurysm patients over a 30-month period. Seven patients (men/women, 2/5; mean age, 45.6 years) with ruptured BBAs were included from two different institutions. The angiographic findings, treatment strategies, and the clinical (modified Rankin Scale) and angiographic outcomes were retrospectively analyzed. All seven BBAs were located in the supraclinoid internal carotid artery. Four of them were ≥ 3 mm in largest diameter. Primary stent-assisted coiling was performed in six out of seven patients, and double stenting was done in one patient. In four patients, the coiling was augmented by overlapping stent insertion. Two patients experienced early re-hemorrhage, including one major fatal SAH. Complementary treatment was required in two patients, including coil embolization and covered-stent placement, respectively. Six of the seven BBAs showed complete or progressive occlusion at the time of late angiographic follow-up. The clinical midterm outcome was good (mRS scores, 0 -1) in five patients. Stent-assisted coiling of a ruptured BBA is technically challenging but can be done with good midterm results. However, as early re-growth/re-rupture remains a problem, repeated, short-term angiographic follow-up is required so that additional treatment can be performed as needed.
Collapse
|
45
|
Kang HC, Kim HT, Kim SS, Kim C, Yu TJ, Lee SK, Kim CM, Kim IJ, Sung JH, Janulewicz KA, Lee J, Noh DY. Single-pulse coherent diffraction imaging using soft x-ray laser. OPTICS LETTERS 2012; 37:1688-1690. [PMID: 22627538 DOI: 10.1364/ol.37.001688] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We report a coherent diffraction imaging (CDI) using a single 8 ps soft x-ray laser pulse at a wavelength of 13.9 nm. The soft x-ray pulse was generated by a laboratory-scale intense pumping laser providing coherent x-ray pulses up to the level of 10(11) photons/pulse. A spatial resolution below 194 nm was achieved with a single pulse, and it was shown that a resolution below 55 nm is feasible with improved detector capability. The single-pulse CDI might provide a way to investigate dynamics of nanoscale molecules or particles.
Collapse
|
46
|
Yu TJ, Lee SK, Sung JH, Yoon JW, Jeong TM, Lee J. Generation of high-contrast, 30 fs, 1.5 PW laser pulses from chirped-pulse amplification Ti:sapphire laser. OPTICS EXPRESS 2012; 20:10807-10815. [PMID: 22565704 DOI: 10.1364/oe.20.010807] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
High-contrast, 30 fs, 1.5 PW laser pulses are generated from a chirped-pulse amplification (CPA) Ti:sapphire laser system at 0.1 Hz repetition rate. The maximum output energy of 60.2 J is obtained, at a pump energy of 120 J, from a booster amplifier that is pumped by four frenquency-doubled Nd:glass laser systems. During amplification, parasitic lasing is suppressed by index matching fluid with absorption dye and the careful manipulation of the time delay between the seed and pump pulses. An amplified pulse passes through a pulse compressor consisting of four gold-coated gratings. After compression, the measured pulse duration is 30 fs, and the output energy is 44.5 J, yielding a peak power of about 1.5 PW. The output energy of 44.5 J and output power of 1.5-PW are the highest values ever achieved from the femtosecond CPA Ti:sapphire laser system. To maintain a sufficiently high temporal contrast, a saturable absorber is installed in the front-end system with two ultrafast Pockels cells in order to minimize the amplified spontaneous emission (ASE) and pre-pulse intensity. An adaptive optics system is implemented for PW laser pulses and a focused intensity of about 1 × 10(22) W/cm(2) can be obtained when an f/3 optic is used.
Collapse
|
47
|
Ihn YK, Sung JH, Kim BS. Intravenous Glycoprotein IIb/IIIa Inhibitor (Tirofiban) Followed by Low-Dose Intra-Arterial Urokinase and Mechanical Thrombolysis for the Treatment of Acute Stroke. Neuroradiol J 2011; 24:907-13. [PMID: 24059896 DOI: 10.1177/197140091102400614] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2011] [Accepted: 09/16/2011] [Indexed: 11/15/2022] Open
Abstract
We investigated the efficacy and safety of the combined use of IV tirofiban and IA urokinase and/or mechanical thrombolysis for treating acute stroke patients. Thirteen, consecutive patients treated with IV tirofiban and IA thrombolysis with mechanical and/or local IA urokinase infusion were evaluated retrospectively. The amount of time before the beginning of treatment, urokinase dose, recanalization rates, and symptomatic hemorrhage were analyzed. Clinical outcome measures were assessed on admission, at discharge (National Institute of Health Stroke scale [NIHSS]), and three months after the end of their treatment (modified Rankin Scale scores [mRS]). There were 11 patients with internal carotid or middle cerebral artery occlusion treated within six hours of the onset of symptoms and two patients with basilar artery occlusion treated within 12 hours of their symptom onset. The median NIHSS score on admission was 18. The median amount of time from symptom onset to IV tirofiban infusion was 135 minutes, and the median time from symptom onset to IA therapy was 180 minutes. The median dose of urokinase was 200,000 U. Recanalization (thrombolysis in myocardial infarction grade 2 or 3) was achieved in 11 patients. No procedure-related complications were observed. There was one symptomatic hemorrhage. At discharge, the mean NIHSS score was 6.6 (range, 0-15). Overall, at the time of the three-month follow-up the functional outcome was favorable (modified Rankin Scale score 0-2) in eight out of 13 (62%) patients. Death at 90 days occurred in two of the 13 (15%) patients. Combined IV tirofiban and IA thrombolysis with mechanical clot disruption seems to be a feasible treatment in acute stroke and may be successful in re-establishing vessel patency and result in a good functional outcome in patients with major cerebral arteries occlusions.
Collapse
|
48
|
Sung JH, Kwak IS, Park SK, Kim HI, Lim HS, Park HJ, Kim SH. Liquid chromatography-tandem mass spectrometry determination of N-nitrosamines released from rubber or elastomer teats and soothers. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2011; 27:1745-54. [PMID: 21108095 DOI: 10.1080/19440049.2010.508184] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method as an alternative to a gas chromatography-thermal energy analyser (GC-TEA) method recommended by the European Committee on Standardization (CEN) was validated for the simultaneous determination of eight N-nitrosamines released into artificial saliva from rubber or elastomer teats and soothers. N-nitroso-dipropylamine-d₁₄ (NDPA-d₁₄) was used as internal standard for accurate quantification. The method was validated with relatively good analytical results, including sufficiently low limits of detection (0.1-2 µg kg⁻¹) of sample) and good linearity (r²> 0.99) throughout the studied concentration ranges. Intra- and inter-day precisions expressed with the relative standard deviation (RSD, %) were 3.4-8.0% and 4.4-11.3%, which were below the performance criteria based on one-half of the value derived from the Horwitz value. It was also found that the LC-MS/MS method is sufficiently rugged and successfully applicable to its routine analysis for the compliance test of Commission Directive 93/11/EEC.
Collapse
|
49
|
Sung JH, Lee SK, Yu TJ, Jeong TM, Lee J. 0.1 Hz 1.0 PW Ti:sapphire laser. OPTICS LETTERS 2010; 35:3021-3023. [PMID: 20847765 DOI: 10.1364/ol.35.003021] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We report on the generation of 1.0 PW, 30 fs laser pulses at a 0.1 Hz repetition rate from a chirped-pulse amplification Ti:sapphire laser system. The energy of the laser pulses is amplified up to 47 J in a final three-pass booster amplifier having 96 J pump energy. To the best of our knowledge, this is the first petawatt Ti:sapphire laser system at a 0.1 Hz repetition rate. The shot-to-shot energy fluctuation of the laser pulses is as low as 0.53% in rms value, and the laser pulses have homogeneous flattop spatial beam profiles.
Collapse
|
50
|
Choi IW, Kim CM, Sung JH, Yu TJ, Lee SK, Kim IJ, Jin YY, Jeong TM, Hafz N, Pae KH, Noh YC, Ko DK, Yogo A, Pirozhkov AS, Ogura K, Orimo S, Sagisaka A, Nishiuchi M, Daito I, Oishi Y, Iwashita Y, Nakamura S, Nemoto K, Noda A, Daido H, Lee J. Ion spectrometer composed of time-of-flight and Thomson parabola spectrometers for simultaneous characterization of laser-driven ions. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2009; 80:053302. [PMID: 19485501 DOI: 10.1063/1.3131628] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
An ion spectrometer, composed of a time-of-flight spectrometer (TOFS) and a Thomson parabola spectrometer (TPS), has been developed to measure energy spectra and to analyze species of laser-driven ions. Two spectrometers can be operated simultaneously, thereby facilitate to compare the independently measured data and to combine advantages of each spectrometer. Real-time and shot-to-shot characterizations have been possible with the TOFS, and species of ions can be analyzed with the TPS. The two spectrometers show very good agreement of maximum proton energy even for a single laser shot. The composite ion spectrometer can provide two complementary spectra measured by TOFS with a large solid angle and TPS with a small one for the same ion source, which are useful to estimate precise total ion number and to investigate fine structure of energy spectrum at high energy depending on the detection position and solid angle. Advantage and comparison to other online measurement system, such as the TPS equipped with microchannel plate, are discussed in terms of overlay of ion species, high-repetition rate operation, detection solid angle, and detector characteristics of imaging plate.
Collapse
|