26
|
Reiber JHC. Editor's choice to the november 2021 issue. Int J Cardiovasc Imaging 2021; 37:3127-3128. [PMID: 34661854 DOI: 10.1007/s10554-021-02442-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Reiber JHC. Editor's choice to the October 2021 issue. Int J Cardiovasc Imaging 2021; 37:2801-2802. [PMID: 34533649 DOI: 10.1007/s10554-021-02409-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
28
|
Hirasawa K, Kuneman JH, Singh GK, Gegenava T, Hautemann D, Reiber JHC, Ajmone Marsan N, Bax JJ, Delgado V. Comparison of left atrial strain measured by feature tracking computed tomography and speckle tracking echocardiography in patients with aortic stenosis. Eur Heart J Cardiovasc Imaging 2021; 23:95-101. [PMID: 34491334 DOI: 10.1093/ehjci/jeab166] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/09/2021] [Indexed: 11/14/2022] Open
Abstract
AIMS Peak left atrial longitudinal strain (PALS) is a marker of the left atrial (LA) reservoir function. Novel feature tracking (FT) software allows assessment of LA strain from multidetector computed tomography (MDCT) data. This study aimed at evaluating the agreement between speckle tracking echocardiography (STE) and FT MDCT for the measurement of PALS in patients with sinus rhythm (SR) and with atrial fibrillation (AF). METHODS AND RESULTS The current study included 318 patients (80 ± 7 years, 54% male) with dynamic MDCT data acquired prior to transcatheter aortic valve implantation. PALS was measured by transthoracic echocardiography using STE (PALSecho) and MDCT using dedicated FT software (PALSCT). In the overall population, the median values of PALSecho and PALSCT were 19.0 [interquartile range (IQR) 12.0-25.0] % and 15.3 (IQR 9.2-19.7) %, respectively. High correlation between PALSecho and PALSCT was observed (r = 0.789, P < 0.001) with a mean bias of -3.7%. The correlation between PALSecho and PALSCT was better among patients with SR (N = 258; r = 0.704, P < 0.001) as compared to patients with AF (N = 60; r = 0.622, P < 0.001). CONCLUSION PALSecho and PALSCT showed a good agreement in patients with severe aortic stenosis (AS) regardless of the cardiac rhythm. FT MDCT may be an important adjuvant modality for assessing LA reservoir function in patients with severe AS.
Collapse
|
29
|
Reiber JHC. Editor's note to the September 2021 issue. Int J Cardiovasc Imaging 2021; 37:2589. [PMID: 34392467 DOI: 10.1007/s10554-021-02381-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
30
|
Reiber JHC. Editor's Note to the July 2021 issue. Int J Cardiovasc Imaging 2021; 37:2093-2094. [PMID: 34156652 DOI: 10.1007/s10554-021-02319-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Wu X, Ono M, Kawashima H, Poon EKW, Torii R, Shahzad A, Gao C, Wang R, Barlis P, von Birgelen C, Reiber JHC, Bourantas CV, Tu S, Wijns W, Serruys PW, Onuma Y. Angiography-Based 4-Dimensional Superficial Wall Strain and Stress: A New Diagnostic Tool in the Catheterization Laboratory. Front Cardiovasc Med 2021; 8:667310. [PMID: 34222366 PMCID: PMC8249568 DOI: 10.3389/fcvm.2021.667310] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 05/21/2021] [Indexed: 12/23/2022] Open
Abstract
A novel method for four-dimensional superficial wall strain and stress (4D-SWS) is derived from the arterial motion as pictured by invasive coronary angiography. Compared with the conventional finite element analysis of cardiovascular biomechanics using the estimated pulsatile pressure, the 4D-SWS approach can calculate the dynamic mechanical state of the superficial wall in vivo, which could be directly linked with plaque rupture or stent fracture. The validation of this approach using in silico models showed that the distribution and maximum values of superficial wall stress were similar to those calculated by conventional finite element analysis. The in vivo deformation was validated on 16 coronary arteries, from the comparison of centerlines predicted by the 4D-SWS approach against the actual centerlines reconstructed from angiograms at a randomly selected time-point, which demonstrated a good agreement of the centerline morphology between both approaches (scaling: 0.995 ± 0.018 and dissimilarity: 0.007 ± 0.014). The in silico vessel models with softer plaque and larger plaque burden presented more variation in mean lumen diameter and resulted in higher superficial wall stress. In more than half of the patients (n = 16), the maximum superficial wall stress was found at the proximal lesion shoulder. Additionally, in three patients who later suffered from acute coronary syndrome, the culprit plaque rupture sites co-localized with the site of highest superficial wall stress on their baseline angiography. These representative cases suggest that angiography-based superficial wall dynamics have the potential to identify coronary segments at high-risk of plaque rupture and fracture sites of implanted stents. Ongoing studies are focusing on identifying weak spots in coronary bypass grafts, and on exploring the biomechanical mechanisms of coronary arterial remodeling and aneurysm formation. Future developments involve integration of fast computational techniques to allow online availability of superficial wall strain and stress in the catheterization laboratory.
Collapse
|
32
|
Reiber JHC. Editor's note to the June 2021 issue. Int J Cardiovasc Imaging 2021; 37:1799-1800. [PMID: 34019205 DOI: 10.1007/s10554-021-02283-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
33
|
Tu S, Westra J, Adjedj J, Ding D, Liang F, Xu B, Holm NR, Reiber JHC, Wijns W. Fractional flow reserve in clinical practice: from wire-based invasive measurement to image-based computation. Eur Heart J 2021; 41:3271-3279. [PMID: 31886479 DOI: 10.1093/eurheartj/ehz918] [Citation(s) in RCA: 55] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 07/27/2019] [Accepted: 12/04/2019] [Indexed: 01/07/2023] Open
Abstract
Fractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance of epicardial coronary stenosis. Despite the overall trend towards more physiology-guided revascularization, there remains a gap between guideline recommendations and the clinical adoption of functional evaluation of stenosis severity. A number of image-based approaches have been proposed to compute FFR without the use of pressure wire and induced hyperaemia. In order to better understand these emerging technologies, we sought to highlight the principles, diagnostic performance, clinical applications, practical aspects, and current challenges of computational physiology in the catheterization laboratory. Computational FFR has the potential to expand and facilitate the use of physiology for diagnosis, procedural guidance, and evaluation of therapies, with anticipated impact on resource utilization and patient outcomes.
Collapse
|
34
|
Reiber JHC. Introduction topical issue on CT plaque burden. Int J Cardiovasc Imaging 2021; 36:2301-2303. [PMID: 33037519 DOI: 10.1007/s10554-020-02055-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
35
|
Groepenhoff F, Eikendal ALM, Bots SH, van Ommen AM, Overmars LM, Kapteijn D, Pasterkamp G, Reiber JHC, Hautemann D, Menken R, Wittekoek ME, Hofstra L, Onland-Moret NC, Haitjema S, Hoefer I, Leiner T, den Ruijter HM. Cardiovascular imaging of women and men visiting the outpatient clinic with chest pain or discomfort: design and rationale of the ARGUS Study. BMJ Open 2020; 10:e040712. [PMID: 33323438 PMCID: PMC7745322 DOI: 10.1136/bmjopen-2020-040712] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
INTRODUCTION Chest pain or discomfort affects 20%-40% of the general population over the course of their life and may be a symptom of myocardial ischaemia. For the diagnosis of obstructive macrovascular coronary artery disease (CAD), algorithms have been developed; however, these do not exclude microvascular angina. This may lead to false reassurance of symptomatic patients, mainly women, with functionally significant, yet non-obstructive coronary vascular disease. Therefore, this study aims to estimate the prevalence of both macrovascular and microvascular coronary vascular disease in women and men presenting with chest pain or discomfort, and to subsequently develop a decision-support tool to aid cardiologists in referral to cardiovascular imaging for both macrovascular and microvascular CAD evaluation. METHODS AND ANALYSIS Women and men with chest pain or discomfort, aged 45 years and older, without a history of cardiovascular disease, who are referred to an outpatient cardiology clinic by their general practitioner are eligible for inclusion. Coronary CT angiography is used for anatomical imaging. Additionally, myocardial perfusion imaging by adenosine stress cardiac MRI is performed to detect functionally significant coronary vascular disease. Electronic health record data, collected during regular cardiac work-up, including medical history, cardiovascular risk factors, physical examination, echocardiography, (exercise) ECG and blood samples for standard cardiovascular biomarkers and research purposes, are obtained. Participants will be classified as positive or negative for coronary vascular disease based on all available data by expert panel consensus (a cardiovascular radiologist and two cardiologists). After completion of the clinical study, all collected data will be used to develop a decision support tool using predictive modelling and machine-learning techniques. ETHICS AND DISSEMINATION The study protocol was approved by the Institutional Review Board of the University Medical Center Utrecht. Results will be disseminated through national and international conferences and in peer-reviewed journals in cardiovascular disease. TRIAL REGISTRATION NUMBER Trialregister.nl Registry NL8702.
Collapse
|
36
|
Smit JM, Koning G, van Rosendael AR, El Mahdiui M, Mertens BJ, Schalij MJ, Jukema JW, Delgado V, Reiber JHC, Bax JJ, Scholte AJ. Referral of patients for fractional flow reserve using quantitative flow ratio. Eur Heart J Cardiovasc Imaging 2020; 20:1231-1238. [PMID: 30535361 DOI: 10.1093/ehjci/jey187] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Accepted: 11/10/2018] [Indexed: 01/11/2023] Open
Abstract
AIMS Quantitative flow ratio (QFR) is a recently developed technique to calculate fractional flow reserve (FFR) based on 3D quantitative coronary angiography and computational fluid dynamics, obviating the need for a pressure-wire and hyperaemia induction. QFR might be used to guide patient selection for FFR and subsequent percutaneous coronary intervention (PCI) referral in hospitals not capable to perform FFR and PCI. We aimed to investigate the feasibility to use QFR to appropriately select patients for FFR referral. METHODS AND RESULTS Patients who underwent invasive coronary angiography in a hospital where FFR and PCI could not be performed and were referred to our hospital for invasive FFR measurement, were included. Angiogram images from the referring hospitals were retrospectively collected for QFR analysis. Based on QFR cut-off values of 0.77 and 0.86, our patient cohort was reclassified to 'no referral' (QFR ≥0.86), referral for 'FFR' (QFR 0.78-0.85), or 'direct PCI' (QFR ≤0.77). In total, 290 patients were included. Overall accuracy of QFR to detect an invasive FFR of ≤0.80 was 86%. Based on a QFR cut-off value of 0.86, a 50% reduction in patient referral for FFR could be obtained, while only 5% of these patients had an invasive FFR of ≤0.80 (thus, these patients were incorrectly reclassified to the 'no referral' group). Furthermore, 22% of the patients that still need to be referred could undergo direct PCI, based on a QFR cut-off value of 0.77. CONCLUSION QFR is feasible to use for the selection of patients for FFR referral.
Collapse
|
37
|
Tenekecioglu E, Katagiri Y, Takahashi K, Tomaniak M, Dudek D, Cequier A, Carrié D, Iñiguez A, Johannes van der Schaaf R, Dominici M, Boven AJV, Helqvist S, Sabaté M, Baumbach A, Piek JJ, Wykrzykowska JJ, Kitslaar P, Dijkstra J, Reiber JHC, Chevalier B, Ural D, Pekkan K, Bourantas CV, Gijsen F, Onuma Y, Torii R, Serruys PW. Endothelial shear stress and vascular remodeling in bioresorbable scaffold and metallic stent. Atherosclerosis 2020; 312:79-89. [PMID: 32979635 DOI: 10.1016/j.atherosclerosis.2020.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 08/12/2020] [Accepted: 08/13/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND AND AIMS The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES) remains elusive. The aim of this study was to determine whether the relationship between ESS and remodeling patterns differs in BRS from those seen in metallic DES at 3-year follow-up. METHODS In the ABSORB II randomized trial, lesions were investigated by serial coronary angiography and intravascular ultrasound (IVUS). Three-dimensional reconstructions of coronary arteries post-procedure and at 3 years were performed. ESS was quantified using non-Newtonian steady flow simulation. IVUS cross-sections in device segment were matched using identical landmarks. RESULTS Paired ESS calculations post-procedure and at 3 years were feasible in 57 lesions in 56 patients. Post-procedure, median ESS at frame level was higher in BRS than in DES, with marginal statistical significance (0.97 ± 0.48 vs. 0.75 ± 0.39 Pa, p = 0.063). In the BRS arm, vessel area and lumen area showed larger increases in the highest tercile of median ESS post-procedure as compared to the lowest tercile. In contrast, in DES, no significant relationship between median ESS post-procedure and remodeling was observed. In multivariate analysis, smaller vessel area, larger lumen area, higher plaque burden post-procedure, and higher median ESS post-procedure were independently associated with expansive remodeling in matched frames. Only in BRS, younger age was an additional significant predictor of expansive remodeling. CONCLUSIONS In a subset of lesions with large plaque burden, shear stress could be associated with expansive remodeling and late lumen enlargement in BRS, while ESS had no impact on vessel dimension in metallic DES.
Collapse
|
38
|
Katagiri Y, Torii R, Takahashi K, Tenekecioglu E, Asano T, Chichareon P, Tomaniak M, Piek JJ, Wykrzykowska JJ, Bullett N, Ahmed N, Al-Lamee K, Al-Lamee R, Leclerc G, Kitslaar P, Dijkstra J, Reiber JHC, Poon EKW, Bourantas CV, Gijsen FJH, Serruys PW, Onuma Y. Preclinical evaluation of a thin-strut bioresorbable scaffold (ArterioSorb): acute-phase invasive imaging assessment and hemodynamic implication. EUROINTERVENTION 2020; 16:e141-e146. [PMID: 31289016 DOI: 10.4244/eij-d-18-01190] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS The aim of this study was to assess the acute performance of the 95 µm ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES) in porcine coronary arteries. METHODS AND RESULTS In 15 non-atherosclerotic Yucatan mini pigs, the ArterioSorb (3.0/14 mm) and XIENCE (3.0/15 mm) were implanted in 25 and 15 vessels, respectively. Acute performance was evaluated by using quantitative coronary angiography (QCA) and optical coherence tomography (OCT). Following three-dimensional reconstruction of the coronary arteries, endothelial shear stress (ESS) was quantified using non-Newtonian steady-flow simulation. Acute recoil measured by QCA was comparable in the two arms. Post-procedural flow and scaffold/stent area by OCT did not differ between the two devices. ESS post procedure was comparable between ArterioSorb and XIENCE (2.21±1.97 vs 2.25±1.71 Pa, p=0.314). CONCLUSIONS Acute recoil, luminal dimensions and ESS in the ArterioSorb oriented PLLA scaffold with thin struts of 95 µm were comparable to those in the XIENCE metallic DES.
Collapse
|
39
|
Safi H, Bourantas CV, Ramasamy A, Zanchin T, Bär S, Tufaro V, Jin C, Torii R, Karagiannis A, Reiber JHC, Mathur A, Onuma Y, Windecker S, Lansky A, Maehara A, Serruys PW, Stone P, Baumbach A, Stone GW, Räber L. Predictive value of the QFR in detecting vulnerable plaques in non-flow limiting lesions: a combined analysis of the PROSPECT and IBIS-4 study. Int J Cardiovasc Imaging 2020; 36:993-1002. [PMID: 32152810 DOI: 10.1007/s10554-020-01805-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 02/22/2020] [Indexed: 01/07/2023]
Abstract
Studies have shown that the quantitative flow ratio (QFR), recently introduced to assess lesion severity from coronary angiography, provides useful prognostic information; however the additive value of this technique over intravascular imaging in detecting lesions that are likely to cause events is yet unclear. We analysed data acquired in the PROSPECT and IBIS-4 studies, in particular the baseline virtual histology-intravascular ultrasound (VH-IVUS) and angiographic data from 17 non-culprit lesions with a presumable vulnerable phenotype (i.e., thin or thick cap fibroatheroma) that caused major adverse cardiac events or required revascularization (MACE) at 5-year follow-up and from a group of 78 vulnerable plaques that remained quiescent. The segments studied by VH-IVUS were identified in coronary angiography and the QFR was estimated. The additive value of 3-dimensional quantitative coronary angiography (3D-QCA) and of the QFR in predicting MACE at 5 year follow-up beyond plaque characteristics was examined. It was found that MACE lesions had a greater plaque burden (PB) and smaller minimum lumen area (MLA) on VH-IVUS, a longer length and a smaller minimum lumen diameter (MLD) on 3D-QCA and a lower QFR compared with lesions that remained quiescent. By univariate analysis MLA, PB, MLD, lesion length on 3D-QCA and QFR were predictors of MACE. In multivariate analysis a low but normal QFR (> 0.80 to < 0.97) was the only independent prediction of MACE (HR 3.53, 95% CI 1.16-10.75; P = 0.027). In non-flow limiting lesions with a vulnerable phenotype, QFR may provide additional prognostic information beyond plaque morphology for predicting MACE throughout 5 years.
Collapse
|
40
|
Kishi S, Magalhães TA, Cerci RJ, Zimmermann E, Matheson MB, Vavere A, Tanami Y, Kitslaar PH, George RT, Brinker J, Miller JM, Clouse ME, Lemos PA, Niinuma H, Reiber JHC, Kofoed KF, Rochitte CE, Rybicki FJ, Di Carli MF, Cox C, Lima JAC, Arbab-Zadeh A. Comparative effectiveness of coronary artery stenosis and atherosclerotic plaque burden assessment for predicting 30-day revascularization and 2-year major adverse cardiac events. Int J Cardiovasc Imaging 2020; 36:2365-2375. [DOI: 10.1007/s10554-020-01851-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 04/10/2020] [Indexed: 11/30/2022]
|
41
|
Gegenava T, van der Bijl P, Vollema EM, van der Kley F, de Weger A, Hautemann D, Reiber JHC, Ajmone Marsan N, Bax JJ, Delgado V. Prognostic Influence of Feature Tracking Multidetector Row Computed Tomography-Derived Left Ventricular Global Longitudinal Strain in Patients with Aortic Stenosis Treated With Transcatheter Aortic Valve Implantation. Am J Cardiol 2020; 125:948-955. [PMID: 31928719 DOI: 10.1016/j.amjcard.2019.12.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 11/29/2022]
Abstract
Computed tomography plays a central role in the evaluation of patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI). Advances in left ventricular (LV) analysis with multidetector row computed tomography (MDCT) permit measurement of LV global longitudinal strain (GLS). The present study aimed at evaluating the association between feature tracking (FT) MDCT derived LV GLS and all-cause mortality in patients treated with TAVI. A total of 214 patients with severe aortic stenosis (51% male, 80 ± 7 years) who underwent TAVI and with dynamic MDCT data allowing LV GLS measurement with novel FT algorithm were included. LV GLS was measured at baseline and were divided according to a previously published cut-off value of LV GLS associated with all-cause mortality (≤-14% [more preserved LV systolic function] vs >-14% [more impaired LV systolic function]). Patients were followed for the occurrence of all-cause mortality. Mean FT MDCT-derived LV GLS was -12.5 ± 4%. During a median follow-up of 45 months (interquartile range: 29 to 62 months), 67 (31%) patients died. The cumulative rate of all-cause mortality for the patients with FT MDCT-derived LV GLS ≤-14% was 15% versus28% for the patients with FT MDCT-derived LV GLS >-14%, Log rank p = 0.001). FT MDCT-derived LV GLS was independently associated with all-cause mortality (hazard ratio: 0.851; 95% confidence interval: 0.772 to 0.937; p = 0.001). In conclusion, impaired FT MDCT-derived LV GLS is independently associated with all-cause mortality in patients treated with TAVI. Besides aortic valve area and calcification, FT MDCT-derived LV GLS is an important prognostic marker.
Collapse
|
42
|
Reiber JHC. Editor's note February 2020. Int J Cardiovasc Imaging 2020; 36:767. [PMID: 32020409 DOI: 10.1007/s10554-020-01780-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
43
|
Spitaleri G, Tebaldi M, Biscaglia S, Westra J, Brugaletta S, Erriquez A, Passarini G, Brieda A, Leone AM, Picchi A, Ielasi A, Girolamo DD, Trani C, Ferrari R, Reiber JHC, Valgimigli M, Sabatè M, Campo G. Quantitative Flow Ratio Identifies Nonculprit Coronary Lesions Requiring Revascularization in Patients With ST-Segment-Elevation Myocardial Infarction and Multivessel Disease. Circ Cardiovasc Interv 2019; 11:e006023. [PMID: 29449325 DOI: 10.1161/circinterventions.117.006023] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 12/26/2017] [Indexed: 11/16/2022]
Abstract
BACKGROUND The nonculprit lesion (NCL) management in ST-segment-elevation myocardial infarction patients with multivessel disease is debated. We sought to assess whether quantitative flow ratio (QFR), a noninvasive tool to identify potentially flow-limiting lesions, may be reliable in this scenario. METHODS AND RESULTS The present proof-of-concept study is based on a 3-step process: (1) identification of the QFR reproducibility in NCLs assessment (cohort A, n=31); (2) prospective validation of QFR diagnostic accuracy in respect to fractional flow reserve (cohort B, n=45); and (3) investigation of long-term clinical outcomes of NCLs stratified according to QFR (cohort C, n=110). A blinded core laboratory computed QFR values for all NCLs. Cohort A showed a good correlation and agreement between QFR values at index (acute) and at staged (subacute, 3-4 days later) procedures (r=0.98; 95% confidence interval, 0.96-0.99; mean difference, 0.004 [-0.027 to 0.34]). The inter-rater agreement was κ=0.9. In cohort B, fractional flow reserve and QFR identified 16 (33%) and 17 (35%) NCLs potentially flow limiting. Sensitivity, specificity, negative, and positive predictive values were 88%, 97%, 94%, and 94%. The area under the receiver operating characteristics curve was 0.96 (95% confidence interval, 0.89-0.99). Finally, in cohort C, we identified 110 ST-segment-elevation myocardial infarction patients where at least 1 NCL was left untreated. Patients with NCLs showing a QFR value ≤0.80 were at higher risk of adverse events (hazard ratio, 2.3; 95% confidence interval, 1.2-4.5; P=0.01). CONCLUSIONS In a limited and selected study population, our study showed that QFR computation may be a safe and reliable tool to guide coronary revascularization of NCLs in ST-segment-elevation myocardial infarction patients.
Collapse
|
44
|
Reiber JHC, Pereira GTR, Bezerra HG, De Sutter J, Schoenhagen P, Stillman AE, Van de Veire NRL. Cardiovascular imaging 2018 in the International Journal of Cardiovascular Imaging. Int J Cardiovasc Imaging 2019; 35:1175-1188. [DOI: 10.1007/s10554-019-01579-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
45
|
Smit JM, El Mahdiui M, van Rosendael AR, Jukema JW, Koning G, Reiber JHC, Bax JJ, Scholte AJ. Comparison of Diagnostic Performance of Quantitative Flow Ratio in Patients With Versus Without Diabetes Mellitus. Am J Cardiol 2019; 123:1722-1728. [PMID: 30853082 DOI: 10.1016/j.amjcard.2019.02.035] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 02/10/2019] [Accepted: 02/13/2019] [Indexed: 12/21/2022]
Abstract
Quantitative flow ratio (QFR) is a novel technique to calculate fractional flow reserve (FFR), without hyperemia induction or a pressure wire, and has not yet been validated in patients with diabetes mellitus (DM), who are at increased risk of coronary microvascular dysfunction. The purpose of our study was to compare the diagnostic performance of QFR in diabetic and nondiabetic patients. Patients who underwent invasive coronary angiography and subsequent invasive FFR measurement within 6 months were included. QFR was determined in all coronary arteries in which invasive FFR was performed, using a dedicated software package. Diagnostic accuracy and the area under the receiver-operating characteristic curve (AUC) were determined for QFR, using an invasive FFR cut-off value of ≤0.80 as the reference standard. In total, 320 coronary arteries from 66 (25%) diabetic and 193 (75%) nondiabetic patients were analyzed. On a vessel-based analysis, diagnostic accuracy, sensitivity, and specificity showed no significant difference between diabetic and nondiabetic patients: 88% versus 85% (p = 0.47), 71% versus 69% (p = 0.72), and 95% versus 91% (p = 0.24). Moreover, the AUC was not significantly different between patients with and without DM, 0.91 versus 0.93 (p = 0.74). The per-vessel AUC was significantly higher for QFR compared with percent diameter stenosis in both diabetic and nondiabetic patients, 0.91 versus 0.76 (p <0.05) and 0.93 versus 0.77 (p <0.001), respectively. In conclusion, we showed a good diagnostic performance of QFR which was independent of the presence of DM.
Collapse
|
46
|
Gao X, Boccalini S, Kitslaar PH, Budde RPJ, Tu S, Lelieveldt BPF, Dijkstra J, Reiber JHC. A novel software tool for semi-automatic quantification of thoracic aorta dilatation on baseline and follow-up computed tomography angiography. Int J Cardiovasc Imaging 2018; 35:711-723. [PMID: 30552522 PMCID: PMC6482131 DOI: 10.1007/s10554-018-1488-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Accepted: 10/30/2018] [Indexed: 01/16/2023]
Abstract
A dedicated software package that could semi-automatically assess differences in aortic maximal cross-sectional diameters from consecutive CT scans would most likely reduce the post-processing time and effort by the physicians. The aim of this study was to present and assess the quality of a new tool for the semi-automatic quantification of thoracic aorta dilation dimensions. Twenty-nine patients with two CTA scans of the thoracic aorta for which the official clinical report indicated an increase in aortic diameters were included in the study. Aortic maximal cross-sectional diameters of baseline and follow-up studies generated semi-automatically by the software were compared with corresponding manual measurements. The semi-automatic measurements were performed at seven landmarks defined on the baseline scan by two operators. Bias, Bland–Altman plots and intraclass correlation coefficients were calculated between the two methods and, for the semi-automatic software, also between two observers. The average time difference between the two scans of a single patient was 1188 ± 622 days. For the semi-automatic software, in 2 out of 29 patients, manual interaction was necessary; in the remaining 27 patients (93.1%), semi-automatic results were generated, demonstrating excellent intraclass correlation coefficients (all values ≥ 0.91) and small differences, especially for the proximal aortic arch (baseline: 0.19 ± 1.30 mm; follow-up: 0.44 ± 2.21 mm), the mid descending aorta (0.37 ± 1.64 mm; 0.37 ± 2.06 mm), and the diaphragm (0.30 ± 1.14 mm; 0.37 ± 1.80 mm). The inter-observer variability was low with all errors in diameters ≤ 1 mm, and intraclass correlation coefficients all ≥ 0.95. The semi-automatic tool decreased the processing time by 40% (13 vs. 22 min). In this work, a semi-automatic software package that allows the assessment of thoracic aorta diameters from baseline and follow-up CTs (and their differences), was presented, and demonstrated high accuracy and low inter-observer variability.
Collapse
|
47
|
Tenekecioglu E, Torii R, Katagiri Y, Chichareon P, Asano T, Miyazaki Y, Takahashi K, Modolo R, Al-Lamee R, Al-Lamee K, Colet C, Reiber JHC, Pekkan K, van Geuns R, Bourantas CV, Onuma Y, Serruys PW. Post-implantation shear stress assessment: an emerging tool for differentiation of bioresorbable scaffolds. Int J Cardiovasc Imaging 2018; 35:409-418. [PMID: 30426299 PMCID: PMC6453863 DOI: 10.1007/s10554-018-1481-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 10/20/2018] [Indexed: 12/27/2022]
Abstract
Optical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to investigate the in-vivo effect of strut thickness and strut protrusion on endothelial wall shear stress (ESS) distribution in ArterioSorb Absorbable Drug-Eluting Scaffold (ArterioSorb) and Absorb everolimus-eluting Bioresorbable Vascular Scaffold (Absorb) devices that struts with similar morphology (quadratic structure) but different thickness. In three animals, six coronary arteries were treated with ArterioSorb. At different six animals, six coronary arteries were treated with Absorb. Following three-dimensional(3D) reconstruction of the coronary arteries, Newtonian steady flow simulation was performed and the ESS were estimated. Mixed effects models were used to compare ESS distribution in the two devices. There were 4591 struts in the analyzed 477 cross-sections in Absorb (strut thickness = 157 µm) and 3105 struts in 429 cross-sections in ArterioSorb (strut thickness = 95 µm) for the protrusion analysis. In cross-section level analysis, there was significant difference between the scaffolds in the protrusion distances. The protrusion was higher in Absorb (97% of the strut thickness) than in ArterioSorb (88% of the strut thickness). ESS was significantly higher in ArterioSorb (1.52 ± 0.34 Pa) than in Absorb (0.73 ± 2.19 Pa) (p = 0.001). Low- and very-low ESS data were seen more often in Absorb than in ArterioSorb. ArterioSorb is associated with a more favorable ESS distribution compared to the Absorb. These differences should be attributed to different strut thickness/strut protrusion that has significant effect on shear stress distribution.
Collapse
|
48
|
Smit JM, Koning G, Van Rosendael AR, El Mahdiui M, Jukema JW, Reiber JHC, Bax JJ, Scholte AJ. P2263Diagnostic performance of quantitative flow ratio in diabetic and non-diabetic patients. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p2263] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
49
|
Collet C, Onuma Y, Sonck J, Asano T, Vandeloo B, Kornowski R, Tu S, Westra J, Holm NR, Xu B, de Winter RJ, Tijssen JG, Miyazaki Y, Katagiri Y, Tenekecioglu E, Modolo R, Chichareon P, Cosyns B, Schoors D, Roosens B, Lochy S, Argacha JF, van Rosendael A, Bax J, Reiber JHC, Escaned J, De Bruyne B, Wijns W, Serruys PW. Diagnostic performance of angiography-derived fractional flow reserve: a systematic review and Bayesian meta-analysis. Eur Heart J 2018; 39:3314-3321. [DOI: 10.1093/eurheartj/ehy445] [Citation(s) in RCA: 90] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 07/31/2018] [Indexed: 01/09/2023] Open
|
50
|
Smit JM, Koning G, Van Rosendael AR, El Mahdiui M, Mertens BJ, Schalij MJ, Jukema JW, Delgado V, Reiber JHC, Bax JJ, Scholte AJ. P4635Referral of patients for fractional flow reserve using quantitative flow ratio. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p4635] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|