26
|
Alio JL, D'Oria F, Toto F, Balgos J, Palazon A, Versaci F, Del Barrio JLA. Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry. EYE AND VISION 2021; 8:37. [PMID: 34615549 PMCID: PMC8496005 DOI: 10.1186/s40662-021-00258-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Accepted: 09/06/2021] [Indexed: 11/10/2022]
Abstract
Background To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer. Methods This study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group); (b) 19 Miniwell; (c) 24 LENTIS Mplus LS-313 MF30; d) 33 LENTIS Mplus LS-313 MF15; (e) 17 AkkoLens Lumina; (f) 31 AT LISA Tri 839MP; (g) 20 Precizon Presbyopic; (h) 20 AcrySof IQ PanOptix; (i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer. Results AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10; P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001). Conclusions Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic.
Collapse
|
27
|
D'Oria F, Palazón A, Alio JL. Corneal collagen cross-linking epithelium-on vs. epithelium-off: a systematic review and meta-analysis. EYE AND VISION (LONDON, ENGLAND) 2021; 8:34. [PMID: 34565473 PMCID: PMC8465763 DOI: 10.1186/s40662-021-00256-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 08/08/2021] [Indexed: 01/08/2023]
Abstract
BACKGROUND The purpose of the study was to determine the advantages and disadvantages of epi-on corneal cross-linking (CXL) techniques compared with standard epi-off CXL. METHODS We searched MEDLINE and EMBASE for randomized controlled trials (RCTs) and non-randomized studies of interventions (NRSIs) and we evaluated the selected papers according to the Cochrane risk of bias tool. We considered, as primary outcomes, average Kmax flattening, changes in uncorrected and corrected distance visual acuity (UDVA and CDVA); as secondary outcomes, we considered changes in pachymetry values and endothelial cell density (ECD). We also investigated adverse events related to the treatments and treatment failure. Meta-analysis was conducted with a fixed or random-effects model using weighted mean difference (MD) with 95% confidence interval (CI) as the effect size. RESULTS A total of 15 studies were included and among these 15 trials, 9 were RCTs and 6 were NRSIs, but only 4 studies showed no high risk of bias and were included in this meta-analysis. Our analysis revealed significant postoperative differences in CDVA (MD = 0.07; 95% CI 0.04 to 0.10; P < 0.001), and no significative differences in UDVA, Kmax, central corneal thickness (CCT) and ECD (P > 0.05). Epi-on CXL protocol was found to be significantly less prompt to have risks of delay in epithelial healing (P = 0.035) and persistent stromal haze (P = 0.026). CONCLUSION Epi-on CXL is as effective as epi-off CXL. Except for a higher significant improvement in CDVA with current epi-on protocols, our meta-analysis demonstrates that epi-on and epi-off CXL have comparable effects on visual, topographic, pachymetric, and endothelial parameters. Epi-on CXL has clinical advantages in terms of comfort and avoidance of complications as it reduces the risk of developing delay in epithelial healing and persistent stromal haze.
Collapse
|
28
|
Abdelghany AA, D’Oria F, Alio Del Barrio J, Alio JL. The Value of Anterior Segment Optical Coherence Tomography in Different Types of Corneal Infections: An Update. J Clin Med 2021; 10:jcm10132841. [PMID: 34199039 PMCID: PMC8267702 DOI: 10.3390/jcm10132841] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 06/03/2021] [Accepted: 06/26/2021] [Indexed: 11/06/2022] Open
Abstract
Anterior segment optical coherence tomography (AS-OCT) is a modality that uses low-coherence interferometry to visualize and assess anterior segment ocular features, offering several advantages of being a sterile and noncontact modality that generates high-resolution cross-sectional images of the tissues. The qualitative and quantitative information provided by AS-OCT may be extremely useful for the clinician in the assessment of a wide spectrum of corneal infections, guiding in the management and follow-up of these patients. In clinical practice, infections are routinely evaluated with slit-lamp biomicroscopy, an examination and imaging modality that is limited by the physical characteristics of light. As a consequence, the depth of pathology and the eventually associated corneal edema cannot be accurately measured with the slit-lamp. Therefore, it represents a limit for the clinician, as in vivo information about corneal diseases and the response to treatment is limited. Resolution of corneal infection is characterized by an early reduction in corneal edema, followed by a later reduction in infiltration: both parameters can be routinely measured with standardized serial images by AS-OCT.
Collapse
|
29
|
Alio JL, Arias A, D’Oria F, Toto F, Del Barrio JA, Duarte R, Artal P. Light scattering in intraocular lenses explanted 15 to 40 years after surgery. BIOMEDICAL OPTICS EXPRESS 2021; 12:3485-3494. [PMID: 34221674 PMCID: PMC8221949 DOI: 10.1364/boe.423652] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 04/28/2021] [Accepted: 05/13/2021] [Indexed: 06/13/2023]
Abstract
The optical quality of intraocular lenses (IOLs) of different materials that have been implanted from 16 to 44 years in human eyes was studied. The IOLs were explanted due to other causes than loss of transparency. The scattered light from the IOLs was assessed in two angular regimes by using dark field images (for wide angles) and the optical integration method (for narrower angles). No evident differences were found in the scattering intensities processed from the dark images. The explanted lenses presented slightly increased amounts of straylight between 1 and 5.1° when compared to a reference new unused lens.
Collapse
|
30
|
Asenjo-Garcia Y, Alio JL. The Spanish Aniridia Association celebrates 25 years. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2021; 96:S0365-6691(21)00091-5. [PMID: 33962812 DOI: 10.1016/j.oftal.2021.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/19/2021] [Accepted: 02/23/2021] [Indexed: 06/12/2023]
|
31
|
D'Oria F, Barraquer R, Alio JL. Crystalline lens alterations in congenital aniridia. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2021; 96:S0365-6691(21)00028-9. [PMID: 33612366 DOI: 10.1016/j.oftal.2020.12.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 12/11/2020] [Accepted: 12/15/2020] [Indexed: 11/27/2022]
Abstract
Congenital aniridia is a rare genetic disease associated with mutations in the PAX6 gene. Changes in the lens in aniridia can be alterations of size and shape, of position - which generally reveal zonular weakness and determines subluxation of the lens - and mainly changes in transparency, cataracts, with variable morphology of polar, cortical, subcapsular, lamellar, and more rarely, nuclear cataract. Visual acuity and quality of vision in patients with congenital aniridia complicated by cataracts can be improved by carefully planned surgery, when lack of media transparency justifies surgical indication. Most patients have some improvement in visual acuity and quality of retinal image. Cataract surgery with aniridia is complicated by pathological changes due to the underlying cause of the aniridia. Challenges include corneal opacification, friable capsule and, above all, iris and pupil reconstruction. It can also determine late complications, such as secondary glaucoma or deterioration of pre-existent glaucoma, and corneal endothelial decompensation. After crystalline lens surgery in these patients, either by cataract or dislocation, for visual rehabilitation there are various techniques such as keratopigmentation, prosthetic iris devices or Morcher intraocular lenses with a black diaphragm. An appropriate individualised surgical plan should be selected depending on patient and surgical experience, in order to minimise complications and give the best chance of postoperative success.
Collapse
|
32
|
D'Oria F, Abdelghany AA, Ledo N, Barraquer RI, Alio JL. Incidence and Reasons for Intrastromal Corneal Ring Segment Explantation. Am J Ophthalmol 2021; 222:351-358. [PMID: 33011155 DOI: 10.1016/j.ajo.2020.09.041] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/22/2020] [Accepted: 09/23/2020] [Indexed: 12/28/2022]
Abstract
PURPOSE To determine the main causes of intrastromal corneal ring segment (ICRS) explantation and define the incidence rate. DESIGN Multicenter, observational consecutive case series. METHODS Consecutive cases of ICRSs explanted in the last 10 years were reviewed. Clinical data included age of the patients at explantation, reasons for implantation and explantation, date of implantation and explantation, tunnel creation technique, and ICRS type. Main outcomes measures were the reasons for ICRS removal and the incidence rate. RESULTS During the study period, 121 ICRSs (119 patients) were explanted, with an explantation rate of 5.60%. Functional failure (74 eyes, 61.16%) represents the main cause for ICRS removal: of them, 48 (39.67%) ICRSs were removed for refractive failure and 26 (21.49%) in the setting of a keratoplasty related to poor visual performance of the implanted eye. In addition, 47 eyes (38.84%) had ICRS removal for anatomic failure: among them, 36 (29.75%) were explanted for spontaneous extrusion (overall extrusion rate: 1.58%), 7 (5.79%) for suspected infectious keratitis, 3 (2.48%) for corneal melting, and 1 (0.83%) for corneal perforation. Mild cases of keratoconus were more prone to be explanted because of a loss of the initial improved visual acuity, whereas spontaneous extrusion happened often in advanced cases of keratoconus. CONCLUSIONS We report the largest series of ICRS explantation as of this writing. The main cause of explantation was functional refractive failure followed by spontaneous extrusion of the ICRS, that is, correlated to an anatomic failure at the site of implantation in an advanced disease.
Collapse
|
33
|
Toprak I, Cavas F, Vega A, Velázquez JS, Alio del Barrio JL, Alio JL. Evidence of a Down Syndrome Keratopathy: A Three-Dimensional (3-D) Morphogeometric and Volumetric Analysis. J Pers Med 2021; 11:jpm11020082. [PMID: 33573177 PMCID: PMC7911434 DOI: 10.3390/jpm11020082] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/26/2021] [Accepted: 01/27/2021] [Indexed: 01/06/2023] Open
Abstract
The aim of this study was to investigate whether a different and abnormal corneal profile is present in Down syndrome (DS) by personalized three-dimensional (3D) modelling. This single-centre cross-sectional study included 43 patients with DS (43 eyes) and 58 age-sex-matched control subjects (58 eyes) with normal karyotype and topography. Refraction, central corneal thickness (CCT), aberrations (high-order, coma and spherical), asphericity and morphogeometric/volumetric parameters based on a 3D corneal model that was generated from raw topographical data were evaluated. Deviation of anterior/posterior apex (Dapexant/Dapexpost) and thinnest point (Dmctant/Dmctpost) from corneal vertex, anterior/posterior surface area (Aant/Apost), sagittal area passing through the anterior/posterior apex (Aapexant/Aapexpost) and thinnest point (Amctpost), total corneal volume (Vtotal) and volumetric progression for each 0.05 mm step of the radius value centred to the thinnest point (VOLMCT) and anterior/posterior apex (VOLAAP/VOLPAP) comprised the morphogeometric/volumetric parameters. In the DS group, 58.1% of the eyes presented abnormal topography. High-order and coma aberrations, asphericity, Dapexant, Aant, Apost and Aapexant were significantly higher, whereas CCT, Aapexpost, Amctpost, Vtotal, VOLAAP, VOLPAP and VOLMCT were lower in the DS group than in the control group (p < 0.05). Dapexpost did not differ between the groups (p > 0.05). This study demonstrates that corneas of the subjects with DS are different and more aberrated than those of normal age- and sex-matched non-DS controls. Anterior corneal apex appears to be displaced in DS even with normal topography, while posterior apex seems stable although topography is abnormal. These findings may help to modify our approach in the diagnosis of keratopathy in subjects with DS.
Collapse
|
34
|
Toprak I, Cavas F, Velázquez JS, Alio del Barrio JL, Alio JL. Subclinical keratoconus detection with three-dimensional (3-D) morphogeometric and volumetric analysis. Acta Ophthalmol 2020; 98:e933-e942. [PMID: 32410342 DOI: 10.1111/aos.14433] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 03/13/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE To assess the efficacy of morphogeometric and volumetric characterization of the cornea based on three-dimensional (3-D) modelling in diagnosis of subclinical keratoconus (KC). METHODS Cross-sectional study. Ninety-three eyes with subclinical KC with a best spectacle-corrected distance visual acuity ≥20/20 (grade zero KC according to the RETICS classification) and 109 control eyes were included. Computer-based 3-D corneal morphogeometric model was generated using raw topographic data. Distance-, area- and volume-based parameters were used for statistical analysis. Distance parameters included deviation of anterior (Dapexant )/posterior (Dapexpost ) apices and minimum thickness points (Dmctant , Dmctpost ) from corneal vertex, and Dapexant -Dapexpost difference. Areal variables were derived from anterior (Aant ) and posterior (Apost ) corneal surfaces, sagittal plane passing through corneal apices (Aapexant , Aapexpost ) and thinnest point (Amctant , Amctpost ). Total corneal volume (Vtotal ) and volumetric distribution (with 0.1mm steps) centred to thinnest corneal point (VOLmct ) and anterior (VOLaap )/posterior (VOLpap ) apices comprised the volume-based parameters. RESULTS In the subclinical KC group, all D values, Dapexant -Dapexpost difference, Aant , Apost and Aapexant values were higher (p < 0.001), while Aapexpost , Amctpost , Vtotal , VOLmct , VOLaap and VOLpap values were lower when compared to the control group (p < 0.001). Regression analysis-based formula correctly classified 96.8% of the eyes with subclinical KC and 94.5% of the normal ones (p < 0.0001). CONCLUSIONS Eyes with subclinical KC seem to represent asymmetrically displaced anterior and posterior corneal apex, corneal thinning and volume loss. 3-D morphogeometric and volumetric parameters and differentiation formula can be incorporated into topography software to detect subclinical KC with high sensitivity and specificity in clinical practice.
Collapse
|
35
|
Primavera L, Canto-Cerdan M, Alio JL, Alio Del Barrio JL. Influence of age on small incision lenticule extraction outcomes. Br J Ophthalmol 2020; 106:341-348. [PMID: 33208352 DOI: 10.1136/bjophthalmol-2020-316865] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/27/2020] [Accepted: 10/31/2020] [Indexed: 11/04/2022]
Abstract
PURPOSE To evaluate the influence of patient's age at the time of surgery on small incision lenticule extraction (SMILE) refractive outcomes. METHODS This is a retrospective, consecutive, comparative study. We compared the refractive outcomes after myopic SMILE from two groups of patients divided by age (patients ≤35 and ≥40 years old). All eyes were evaluated preoperatively and at 1 and 6 months postoperatively. Main outcome measures were differences on efficacy, safety, predictability and astigmatic changes by vector analysis with ASSORT software between both study groups. RESULTS 102 matched eyes of 53 patients were included. Preoperatively, we evidenced no differences in the mean SE or astigmatism between groups. However, 6 months postoperatively we observed a significantly worse mean astigmatism (p=0.019), while not regarding SE, in the older population, with a trend towards undercorrection of the refractive cylinder in the ≥40 group. We also observed a statistically significant difference in the efficacy (0.86-1 month and 0.97-6 months in ≥40group vs 0.97-1 month and 1.07-6 months in the ≤35 group; p=0.003) and safety indexes (0.93-1 month and 1.04-6 months in ≥40 group vs 1.0-1 month and 1.11-6 months in the ≤35 group; p=0.008) at 6 months among groups. CONCLUSIONS Post-SMILE refractive outcomes in those patients over 40 years of age, although acceptable, are not as good as those obtained in younger patients, showing a significantly lower efficacy and safety indexes, and poorer astigmatic outcomes, with a tendency towards undercorrection. We hypothetise that the increased corneal stroma stiffness in the aged group modifies the post-SMILE corneal stroma remodelling capacity, thus affecting the SMILE refractive and visual response.
Collapse
|
36
|
Alio Del Barrio JL, Parafita-Fernandez A, Canto-Cerdan M, Alio JL, Teus M. Evolution of corneal thickness and optical density after laser in situ keratomileusis versus small incision lenticule extraction for myopia correction. Br J Ophthalmol 2020; 105:1656-1660. [PMID: 32980816 DOI: 10.1136/bjophthalmol-2020-316601] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/19/2020] [Accepted: 09/06/2020] [Indexed: 11/04/2022]
Abstract
PURPOSE To compare the thickness and stromal optical density (OD) evolution of the flap and cap after femtosecond (FS-LASIK; Visumax) and small incision lenticule extraction (SMILE), respectively, for myopia correction. METHODS A prospective study comprising 78 eyes (n=39 per group) was performed. Anterior segment optical coherence tomography (MS39) images were collected at each postoperative visit (1 day, 1 week and 1 and 3 months) and flap/cap thicknesses were measured. Using ImageJ software, three regions were defined to measure OD (in grayscale units: flap/cap stroma, residual stromal bed (RSB) and all stroma (including flap/cap-stroma, surgical interface and RSB). RESULTS Mean central thickness significantly increased during the 3-month follow-up in both LASIK (5.43±4.23 μm; p=0.0118) and SMILE (2.76±5.61 μm; p=0.0118), with differences between both techniques statistically significant (p=0.020). All OD values showed a statistically significant reduction during SMILE follow-up: cap 48.96±5.55 versus 44.95±5.41 (p=0.19×10-6), RSB 50.26±7.06 versus 45.42±7.53 (p=0.00005), total stroma 50.34±6.49 versus 45.46±6.96 (p=0.5×10-5) at 1 day and 3 months, respectively, whereas no statistically significant changes were found during LASIK follow-up. No significant differences were observed in OD values between both techniques at any time point, although SMILE showed a tendency for higher OD values than LASIK within the first postoperative month. Visumax presented a tendency for thicker caps than target (11.48±7.85 μm), but not for flaps (2.73±8.93 μm) (p=0.00003). CONCLUSIONS Both LASIK flaps and SMILE caps show a significant postoperative rethickening. SMILE corneas present higher optical densities than LASIK corneas in the early postoperative period, with a significant decrease thereafter and up to 3 months. These findings correlate with the delayed visual recovery observed after SMILE.
Collapse
|
37
|
Rodriguez AE, Gisbert S, Palazón A, Alio JL. Quantification of Growth Factors and Fibronectin in Diverse Preparations of Platelet-Rich Plasma for the Treatment of Ocular Surface Disorders (E-PRP). Transl Vis Sci Technol 2020; 9:22. [PMID: 32821519 PMCID: PMC7409215 DOI: 10.1167/tvst.9.6.22] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 03/26/2020] [Indexed: 01/11/2023] Open
Abstract
Purpose The purpose of this study was to quantify the presence of growth factors (GFs) and fibronectin in autologous platelet-rich plasma for topical ocular use (E-PRP) comparing their concentration when different preparation and preservation procedures were applied. Methods E-PRP was prepared with blood from healthy volunteers. The count of platelets, leukocytes, and red blood cells in the whole blood and E-PRP were performed. The concentration of the GFs platelet-derived growth factor BB (PDGF-BB), transforming growth factor β1 (TGF-β1), epidermal growth factor (EGF), vascular endothelial growth factor A (VEGF-A), and fibronectin was determined in each of the four procedures applied including fresh, frozen at −20°C for 3 months, fresh-spin, and frozen-spin at −20°C E-PRP samples. Posterior statistical analysis was performed to establish significant differences between groups and between GFs in relation to the amounts of platelets. Results Platelets in the E-PRP doubled in the number of basal values of whole blood (P ≤ 0.01). The blood cells in the E-PRP decreased drastically in red cells (99%) and also in leukocytes (82%). The concentration of PDGF-BB and EGF was significantly higher (P < 0.01) when the E-PRP samples were frozen at −20°C. However, no significant differences were observed for TGF-β1, VEGF-A, and fibronectin (P > 0.05). The concentration of GFs in the E-PRP did not necessarily correlate with the number of platelets. Conclusions Freezing the E-PRP for 3 months at −20°C increased the concentration of important proteins, such as PDGF-BB and EGF, and maintained the levels of others. These findings are essential because treatments, such as E-PRP, used by patients with ocular surface dysfunctions tend to prolong it in time. In addition, subsequent centrifugation of the E-PRP decreased the values of TFG-β1, but not the other GFs, which would allow adjusting the concentration of TFG-β1, as necessary. This procedure guarantees their correct conservation and viability. Translational Relevance This work demonstrates how clinical application can be improved by starting from basic research. The quantification of GFs and fibronectin in platelet-rich plasma (PRP) helps to clarify which is the best mode of preparation and preservation of PRP for clinical applications. This allows to optimize the product that is delivered to the patients as a treatment for the dysfunctions of the ocular surface, guaranteeing that the conservation does not affect at all the quality of the PRP that it is going to be used.
Collapse
|
38
|
Abdelghany AA, D'Oria F, Alio JL. Surgery for glaucoma in modern corneal graft procedures. Surv Ophthalmol 2020; 66:276-289. [PMID: 32827497 DOI: 10.1016/j.survophthal.2020.08.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 08/12/2020] [Accepted: 08/17/2020] [Indexed: 12/20/2022]
Abstract
Glaucoma is a common cause of vision loss after corneal transplantion and is considered a major risk factor for graft failure. Glaucoma may be present before corneal transplant surgery, or increased intraocular pressure may develop after keratoplasty in up to one-third of patients. Pre-existing glaucoma should be controlled before keratoplasty, either medically or surgically. For postkeratoplasty increase in intraocular pressure; identifying the risk factors allows appropiate follow-up and management. Patients undergoing anterior lamellar keratoplasty may take advantage of reduced rates of postkeratoplasty glaucoma. Glaucoma also complicates eyes with endothelial keratoplasties, mostly related to management of intraocular pressure spikes derived from anterior chamber air bubbles. Nevertheless, the severity is less, and the intraocular pressure is more easily controlled when compared with penetrating keratoplasty. Adequate management of glaucoma that develops before or after keratoplasty may save eyes from irreversible damage to the optic nerve and increase graft survival.
Collapse
|
39
|
Alio JL, Montesel A, El Sayyad F, Barraquer RI, Arnalich-Montiel F, Alio Del Barrio JL. Corneal graft failure: an update. Br J Ophthalmol 2020; 105:1049-1058. [DOI: 10.1136/bjophthalmol-2020-316705] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/29/2020] [Accepted: 07/03/2020] [Indexed: 11/04/2022]
Abstract
Corneal graft surgery is one of the most successful forms of human solid-tissue transplantation, and nowadays, there is a worldwide expansion of the surgical volume of corneal grafts. This surgery is continuously evolving, with new surgical techniques and postoperative treatments that have considerably increased the chance of survival for the grafts. Despite the high rate of success, corneal transplantation is still complicated by a relevant risk of graft failure. This study investigates the causes that lead to the failure of the different corneal graft surgical techniques and provides an updated synthesis on this topic. A comprehensive review of the main pathological pathways that determine the failure of corneal grafts is provided, analysing the main risk factors and disclosing the survival rates of the principal form of corneal grafts. Our results revealed that penetrating keratoplasty has higher failure rates than lamellar keratoplasty, with immunological rejection being the leading cause of graft failure, followed by late endothelial failure (LEF) and ocular surface disorders. Postoperative glaucoma and dehiscence of the surgical wound represent other important causes of failure. Endothelial keratoplasty showed the lowest rates of failure in the mid-term, with LEF, detachment of the graft and primary graft failure representing the most common pathological reasons for failure.
Collapse
|
40
|
Vargas V, Marinho A, El Sayyad F, Alio Del Barrio JL, Alio JL. Safety and visual outcomes following Iris-claw phakic intraocular lens bilensectomy. Eur J Ophthalmol 2020; 31:1795-1801. [PMID: 32715788 DOI: 10.1177/1120672120944033] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the visual outcomes, safety, efficacy, and causes of bilensectomy for iris fixated phakic intraocular lenses (pIOLs). METHODS This was a two center consecutive retrospective study that included 43 eyes that underwent iris-claw pIOL bilensectomy. Patients with follow up less than 4 months were excluded from the study. Uncorrected, corrected visual acuity (UCVA, CDVA), refractive outcomes, efficacy, safety (number of eyes in which the postoperative CDVA was worse than the preoperative CDVA), endothelial cell density (ECD), causes of bilensectomy, the time between the implantation of the pIOL and bilensectomy, intra and postoperative complications were analyzed. RESULTS There was a statistically significant improvement in UCVA and CDVA after surgery (p = 0.001). The efficacy index was 0.7, four eyes had a postoperative CDVA worse than the preoperative CDVA. The mean spherical equivalent 1 year after bilensectomy was -0.78 ± 1.70 D. There was a statistically significant endothelial cell loss after iris claw lens bilensectomy (p = .003). Cataract development and endothelial cell loss were the only reasons for bilensectomy. The mean time between pIOL implantation and bilensectomy was 12.2 ± 5.5 years. One patient had corneal edema 8 months after surgery and one had a retinal detachment 11 months after surgery. CONCLUSION Bilensectomy was successful in improving UCVA and CDVA with an acceptable refractive outcome. Significant loss of ECD was found after surgery. The results recommend a larger ACD as selection criteria when choosing to implant an Artisan lens, and a close postoperative monitoring of the endothelial cell count.
Collapse
|
41
|
Velázquez JS, Cavas F, Piñero DP, Cañavate FJ, Alio del Barrio J, Alio JL. Morphogeometric analysis for characterization of keratoconus considering the spatial localization and projection of apex and minimum corneal thickness point. J Adv Res 2020; 24:261-271. [PMID: 32382446 PMCID: PMC7200195 DOI: 10.1016/j.jare.2020.03.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 03/26/2020] [Accepted: 03/26/2020] [Indexed: 02/07/2023] Open
Abstract
This work evaluates changes in new morphogeometric indices developed considering the position of anterior and posterior corneal apex and minimum corneal thickness (MCT) point in keratoconus. This prospective comparative study included 440 eyes of 440 patients (age, 7-99 years): control (124 eyes) and keratoconus (KC) groups (316 eyes). Tomographic information (Sirius®, Costruzione Strumenti Oftalmici, Italy) was treated with SolidWorks v2013, creating the following morphogeometric parameters: geometric axis-apex line angle (GA-AP), geometric axis-MCT line angle (GA-MCT, apex line-MCT line angle (AP-MCT), and distances between apex and MCT points on the anterior (anterior AP-MCTd) and posterior corneal surface (posterior AP-MCTd). Statistically significant higher values of GA-AP, GA-MCT, AP-MCT and anterior AP-MCTd were found in the keratoconus group (p ≤ 0.001). Moderate significant correlations of corneal aberrations (r ≥ 0.587, p < 0.001) and corneal thickness parameters (r ≤ -0.414, p < 0.001) with GA-AP and AP-MCT were found. Anterior asphericity was found to be significantly correlated with anterior and posterior AP-MCTd (r ≥ 0.430, p < 0.001). Likewise, GA-AP and AP-MCT showed a good diagnostic ability for the detection of keratoconus, with optimal cutoff values of 9.61° (sensitivity 85.5%, specificity 80.3%) and 18.08° (sensitivity 80.5%, specificity 78.7%), respectively. These new morphogeometric indices allow a clinical characterization of the 3-D structural alteration occurring in keratoconus, with less coincidence in the spatial projection of the apex and MCT points of both corneal surfaces. Future studies should confirm the potential impact on the precision of these indices of the variability of posterior corneal surface measurements obtained with Scheimpflug imaging technology.
Collapse
|
42
|
Kanclerz P, Alio JL. The benefits and drawbacks of femtosecond laser-assisted cataract surgery. Eur J Ophthalmol 2020; 31:1021-1030. [PMID: 32508179 DOI: 10.1177/1120672120922448] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
INTRODUCTION Since the introduction, femtosecond laser-assisted cataract surgery was believed to revolutionize cataract surgery. However, the judgment of clinical benefit was found to be far more complex than initially might have been thought. The aim of this review was to analyze the benefits and drawbacks of femtosecond laser-assisted cataract surgery compared with traditional phacoemulsification cataract surgery. METHODS PubMed and the Web of Science were used to search the medical literature. The following keywords were searched in various combinations: femtosecond laser, femtosecond laser-assisted cataract surgery, phacoemulsification cataract surgery, FLACS. RESULTS The benefits of femtosecond laser-assisted cataract surgery include lower cumulated phacoemulsification time and endothelial cell loss, perfect centration of the capsulotomy, and opportunity to perform precise femtosecond-assisted arcuate keratotomy incisions. The major disadvantages of femtosecond laser-assisted cataract surgery are high cost of the laser and the disposables for surgery, femtosecond laser-assisted cataract surgery-specific intraoperative capsular complications, as well as the risk of intraoperative miosis and the learning curve. CONCLUSION Femtosecond laser-assisted cataract surgery seems to be beneficial in some groups of patients, that is, with low baseline endothelial cell count, or those planning to receive multifocal intraocular lens. Nevertheless, having considered that the advantages of femtosecond laser-assisted cataract surgery might not be clear in every routine case, it cannot be considered as cost-effective.
Collapse
|
43
|
Vargas V, Alio JL, Oliveira RF, Renna A, Yebana P. Long-term objective and subjective outcomes following bilateral implantation of diffractive bifocal or trifocal intraocular lenses. Eur J Ophthalmol 2020; 31:1014-1020. [PMID: 32460552 DOI: 10.1177/1120672120926870] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate and compare the objective and subjective outcomes after the bilateral implantation of a diffractive bifocal and trifocal intraocular lens. METHODS This is a case-control, single-center observational study which included 27 patients; 16 patients were implanted bilaterally with the bifocal AcrySof IQ ReSTOR+3.0D and 11 patients with the trifocal AT LISA tri 839MP. Uncorrected visual acuity at distance, intermediate, and near under mesopic and photopic conditions using ETDRS charts with 10% and 100% contrast, corrected distance visual acuity, and binocular defocus curve in photopic conditions; binocular contrast sensitivity under mesopic and photopic conditions for far and near distances were assessed. The Visual Function Questionnaire-25 questionnaire was used to assess patients' satisfaction. All the measurements were performed 6-24 months after cataract surgery. RESULTS The ReSTOR group had better binocular uncorrected near visual acuity in photopic conditions with low and high contrast charts (p = 0.040 and p = 0.033, respectively), as well as in far contrast sensitivity measurement under mesopic conditions with a spatial frequency of 3 cycles per degree (p = 0.034). There was not a significant difference between the two study groups in uncorrected near, intermediate or distance vision under mesopic conditions. The AT LISA tri study group had better subjective outcomes. CONCLUSION Both intraocular lenses restore visual acuity after cataract surgery. The ReSTOR intraocular lens provides better objective outcomes than the AT LISA tri, although the latter provides better subjective outcomes. The relevance of this study is the evaluation of both objective and subjective outcomes.
Collapse
|
44
|
Fariselli C, Toprak I, Al-Shymali O, Alio Del Barrio JL, Alio JL. Corneal transplantation outcomes after the extrusion of an intrastromal keratoprosthesis: a pilot study. EYE AND VISION 2020; 7:26. [PMID: 32411808 PMCID: PMC7206721 DOI: 10.1186/s40662-020-00193-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 04/16/2020] [Indexed: 11/17/2022]
Abstract
This short report includes 5 eyes of 5 patients (mean age 63.2 ± 12 years) who underwent a tectonic keratoplasty [deep anterior lamellar keratoplasty (DALK) or penetrating keratoplasty (PK)] in order to rehabilitate the eye after the extrusion of the non-perforating keratoprosthesis (Kpro) KeraKlear (KeraMed, USA). The non-perforating Kpro was extruded after a mean period of 21.4 ± 21.8 months due to melting. In two cases, the keratoplasty was performed the same day of the non-perforating Kpro removal due to a severe melting, while in the other three cases it was performed one to 3 months later. Two eyes received a DALK, but in 3 eyes a macroscopic Descemet membrane perforation forced the conversion into a PK. The mean follow-up period after the keratoplasty was 16.8 ± 6.6 months. No cases of rejection were recorded. All the 5 eyes achieved “anatomical success” (transparent graft, with no signs of infection or inflammation). Two eyes showed limited “functional success” because the achievement of the best visual potential was prevented by the development of glaucomatous optic atrophy during the follow-up period. In conclusion, this short report presents an unexpected success of a keratoplasty performed with a tectonic purpose after the extrusion of the non-perforating Kpro because the corneal graft remained transparent, without neovascularization or scarring during the follow-up period. This initial evidence shows some encouraging results regarding graft survival rate and the achievement of a useful visual rehabilitation with keratoplasty after a non-perforating Kpro failure instead of repeating the Kpro implantation.
Collapse
|
45
|
Kanclerz P, Toto F, Grzybowski A, Alio JL. Extended Depth-of-Field Intraocular Lenses: An Update. Asia Pac J Ophthalmol (Phila) 2020; 9:194-202. [PMID: 32511121 PMCID: PMC7299221 DOI: 10.1097/apo.0000000000000296] [Citation(s) in RCA: 75] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 04/07/2020] [Indexed: 11/25/2022] Open
Abstract
Extended depth-of-focus (EDOF) is a new intraocular lens (IOL) technology in the treatment of presbyopia. In contrast to multifocal (MF) IOLs, EDOF lenses create a single elongated focal point, rather than several foci, to enhance depth of focus. In this way, EDOF IOLs aim to reduce photic phenomena, glare, and halos, which have been reported in MF IOLs. A potential disadvantage is a decrease of retinal image quality if the amount of the aberrations is excessively increased. Frequently, EDOF IOLs are combined with MF optical designs; for this reason, EDOF IOLs are commonly a subject of confusion with optical multifocality concepts. The aim of this article is to clarify what an EDOF IOL is and to discuss the recently reported outcomes with these IOLs. We propose naming lenses that have combined optical designs as "hybrid IOLs."
Collapse
|
46
|
Fariselli C, Vega-Estrada A, Arnalich-Montiel F, Alio JL. Artificial neural network to guide intracorneal ring segments implantation for keratoconus treatment: a pilot study. EYE AND VISION 2020; 7:20. [PMID: 32292796 PMCID: PMC7144046 DOI: 10.1186/s40662-020-00184-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 03/10/2020] [Indexed: 02/01/2023]
Abstract
Background To analyze the clinical results of an artificial neural network (ANN) that has been processed in order to improve the predictability of intracorneal ring segments (ICRS) implantation in keratoconus. Methods This retrospective, comparative, nonrandomized, pilot, clinical study included a cohort of 20 keratoconic eyes implanted with intracorneal ring segments KeraRing (Mediphacos, Belo Horizonte, Brazil) using the ANN (ANN group) and 20 keratoconic eyes implanted with KeraRing using the manufacturer’s nomograms (nomogram group). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA) (visual acuity is expressed in decimal value and in LogMAR value in brackets), manifest refraction, corneal topography, tomography, aberrometry, pachymetry and volume analysis (Sirius System. CSO, Firenze, Italy) were performed during the preoperative visit; and the two groups, ANN group and nomogram group, did not differ significantly preoperatively in all of the parameters evaluated. These preoperative values were compared with the results obtained at the third-month visit. Mann-Whitney test and Wilcoxon test were used for the statistical analyses. Results The spherical equivalent and the keratometric values decreased significantly in both groups. The CDVA improved from 0.60 ± 0.23 (0.22 LogMAR) pre-operatively to 0.73 ± 0.21 (0.14 LogMAR) post-operatively in the ANN group (p < 0.005), and from 0.54 ± 0.19 (0.27 LogMAR) pre-operatively to 0.62 ± 0.19 (0.21 LogMAR) post-operatively in the nomogram group (p < 0.01), with statistically significant difference between the two groups (p < 0.05), being better in the ANN group. Coma-like aberrations decreased significantly in the ANN group, while in the nomogram group they did not change significantly, but no statistically significant difference was found between the two groups. Conclusions ANN to guide ICRS provides an increase in the visual acuity, reduction in the spherical equivalent and improvement in the optical quality of keratoconus patients. ANN gives better results when compared with the manufacturer’s nomograms in terms of better corrected vision and reduction of the coma-like aberrations. The constant inclusion of new cases will make the predictability of ANN increasingly better as the software finetunes its learning.
Collapse
|
47
|
Vega-Estrada A, Fariselli C, Alio JL. Posterior corneal features in patients with Down syndrome and their relation with keratoconus. Br J Ophthalmol 2020; 104:1683-1689. [PMID: 32122914 DOI: 10.1136/bjophthalmol-2019-314939] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 12/13/2019] [Accepted: 02/13/2020] [Indexed: 11/03/2022]
Abstract
AIMS To characterise posterior corneal surface features in patients with Down syndrome (DS) and to compare them with healthy and mild keratoconus corneas. METHODS This restrospective, comparative, non-randomised, clinical study included 123 eyes, divided into three groups (37 eyes of patients with DS, 46 with mild keratoconus and 40 controls), and took place at Vissum Alicante. Only patients with no previous ocular surgery, no corneal scars and no active ocular disease other than keratoconus were included. The Sirius System topographer (CSO, Firenze, Italy) was used in order to analyse posterior corneal surface keratometry, shape and keratoconus screening indices, posterior corneal aberrations, corneal volume and pachymetry. RESULTS Patients with DS, when compared with healthy controls, have a steeper (mean keratometry 7 mm (KM): -6.30±0.44 vs -6.15±0.22; p<0.05) and more irregular (root mean square per unit of area: 4.5 mm 0.22±0.22 vs 0.09±0.03, p<0.001; posterior vertex of the ectatic area: 33.22±44.29 vs 10.63±2.88, p<0.001) posterior corneal surface, with higher aberrations (high-order aberrations (HOAs): 1.07±1.43 vs 0.15±0.06, p<0.001; coma-like: 0.88±1.09 vs 0.13±0.07, p<0.001) and thinnest pachymetry (497.68±26.88 vs 538.95±31.67, p<0.001). At the same time, no statistically significant difference was found between patients with DS and patients with mild keratoconus (p>0.05) in KM (-6.38±0.34), HOA (0.56±0.36), coma-like (0.51±0.34) and pachymetry (500.56±36.83). CONCLUSIONS Posterior corneal surface of patients with DS is steeper, more irregular and shows more higher order aberrations, as well as reduced volume and thinner pachymetry than patients with healthy corneas. Additionally, posterior corneal surface in patients with DS shows similar characteristics to those found in mild keratoconus.
Collapse
|
48
|
Valera-Cornejo DA, Vega-Estrada A, Alio JL. Invasive Pharmacology Outcomes with Different Corneal Cross-Linking Protocols: A Review. J Ocul Pharmacol Ther 2019; 35:475-490. [DOI: 10.1089/jop.2018.0144] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
|
49
|
Alio JL, Vega-Estrada A, Sanz P, Osman AA, Kamal AM, Mamoon A, Soliman H. Corneal Morphologic Characteristics in Patients With Down Syndrome. JAMA Ophthalmol 2019; 136:971-978. [PMID: 29931124 DOI: 10.1001/jamaophthalmol.2018.2373] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Importance Literature suggests corneal morphologic characteristics compatible with keratoconus are present in a high percentage of patients with Down syndrome (DS), suggesting the need to perform a detailed examination of the anterior segment to try to avoid serious visual impairment in this group of patients. Objective To characterize the abnormal features of the cornea in patients with DS and compare these with a control group. Design, Setting, and Participants Multicenter case-control study at Vissum Alicante, Alicante, Spain, and the Ophthalmology and Pediatric Department, Cairo University, Cairo, Egypt. Data collection took place between May 2013 and May 2016. Data were analyzed between June 2016 and August 2016. The study included 321 eyes of 217 participants from 2 groups: 112 participants in the DS group and 105 healthy participants in the control group. Interventions Patients were evaluated using Placido disc/Scheimpflug camera topographer (Sirius, CSO). Visual, refractive and anterior, and posterior corneal characteristics were assessed and compared in both groups. Main Outcomes and Measures Keratoconus diagnosis. Incidence of corneal morphologic irregularities similar to keratoconus in patients with DS. Results In the DS group, mean (SD) age was 14.88 (15.76) years, 54 (48%) were women, 66 (59%) were white, and 46 (41%) were Arab. In the control group, mean (SD) age was 40.29 (14.66) years, 54 (51%) were women, and all were white. Clinical assessment of corneal topography showed that 71.3% (95% CI, 45.2-97.4) of patients in the DS group showed characteristics compatible with keratoconus. Differences were found in steepest keratometry of 47.35 diopters (D) in patients with DS vs 43.70 D in control individuals (difference, 3.65 D; 95% CI, 3.23-4.35 D; P <.001) and in corneal pachymetry of 503 μm in patients with DS vs 545 μm in control individuals (difference, 42 μm; 95% CI, 38.8-56.7 μm; P <.001). Conclusions and Relevance Patients with DS have steeper and thinner corneas and more corneal aberrations than those without genetic alterations and normal corneas. The findings suggest a detailed corneal study should be considered in such patients to detect keratoconus and implement treatment as appropriate to try to avoid serious visual impairment in this group of patients.
Collapse
|
50
|
Balgos JD, Amesty MA, Rodriguez AE, Al-Shymali O, Abumustafa S, Alio JL. Keratopigmentation combined with strabismus surgery to restore cosmesis in eyes with disabling corneal scarring and squint. Br J Ophthalmol 2019; 104:785-789. [PMID: 31527061 DOI: 10.1136/bjophthalmol-2019-314539] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 08/21/2019] [Accepted: 08/22/2019] [Indexed: 11/04/2022]
Abstract
BACKGROUND Therapeutic corneal pigmentation has modernly evolved into different sophisticated techniques to camouflage cosmetically disabling corneal opacities and scars with good reported outcomes. Blind eyes frequently suffer from strabismus which further deteriorates the cosmesis of the patient. Combined keratopigmentation (KTPG) with strabismus surgery may be an option for these patients. METHODS A total of 72 consecutive patients were retrospectively reviewed in this investigation. Main outcome measures were postoperative residual squint, and cosmesis evaluated by an independent observer, patient satisfaction, reoperation rates for KTPG and squint, and complications. RESULTS A total of 72 consecutive patients and 73 eyes that underwent KTPG and strabismus surgery were included in this study. Mean follow-up time was 2.5±3 years. Patient age ranged from 5 to 83 years, with 93% having visual acuity worse than 0.1. 14 eyes (24.5%) underwent repeated KTPG, 24 (42.1%) had repeated strabismus surgery. 14 patients (19.4%) had a repeat muscle surgery, although 55 (76.4%) of the 72 patients achieved orthotropia or had deviations within 10 prism dioptres at the end of the follow-up period. Corneal microperforation was encountered in two (2.8%) patients and conjunctival staining in 10 eyes. Cosmesis was good for all patients. Patients who required repeat KTPG or strabismus surgery, or those in whom orthotropia was not totally restored, considered their cosmetic appearance sufficiently improved. CONCLUSION Corneal KTPG combined with strabismus surgery provides good cosmesis for patients with corneal scarring and strabismus with minimal complications. Reoperation rates are relatively high in the short term to accomplish an optimal cosmetic result.
Collapse
|