26
|
Schrijver I, Aziz N, Farkas DH, Furtado M, Gonzalez AF, Greiner TC, Grody WW, Hambuch T, Kalman L, Kant JA, Klein RD, Leonard DGB, Lubin IM, Mao R, Nagan N, Pratt VM, Sobel ME, Voelkerding KV, Gibson JS. Opportunities and challenges associated with clinical diagnostic genome sequencing: a report of the Association for Molecular Pathology. J Mol Diagn 2012; 14:525-40. [PMID: 22918138 PMCID: PMC6504171 DOI: 10.1016/j.jmoldx.2012.04.006] [Citation(s) in RCA: 101] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2012] [Revised: 04/12/2012] [Accepted: 04/19/2012] [Indexed: 02/07/2023] Open
Abstract
This report of the Whole Genome Analysis group of the Association for Molecular Pathology illuminates the opportunities and challenges associated with clinical diagnostic genome sequencing. With the reality of clinical application of next-generation sequencing, technical aspects of molecular testing can be accomplished at greater speed and with higher volume, while much information is obtained. Although this testing is a next logical step for molecular pathology laboratories, the potential impact on the diagnostic process and clinical correlations is extraordinary and clinical interpretation will be challenging. We review the rapidly evolving technologies; provide application examples; discuss aspects of clinical utility, ethics, and consent; and address the analytic, postanalytic, and professional implications.
Collapse
|
27
|
Coonrod EM, Durtschi JD, Margraf RL, Voelkerding KV. Developing genome and exome sequencing for candidate gene identification in inherited disorders: an integrated technical and bioinformatics approach. Arch Pathol Lab Med 2012; 137:415-33. [PMID: 22770468 DOI: 10.5858/arpa.2012-0107-ra] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT Advances in sequencing technology with the commercialization of next-generation sequencing (NGS) has substantially increased the feasibility of sequencing human genomes and exomes. Next-generation sequencing has been successfully applied to the discovery of disease-causing genes in rare, inherited disorders. By necessity, the advent of NGS has fostered the concurrent development of bioinformatics approaches to expeditiously analyze the large data sets generated. Next-generation sequencing has been used for important discoveries in the research setting and is now being implemented into the clinical diagnostic arena. OBJECTIVE To review the current literature on technical and bioinformatics approaches for exome and genome sequencing and highlight examples of successful disease gene discovery in inherited disorders. To discuss the challenges for implementing NGS in the clinical research and diagnostic arenas. DATA SOURCES Literature review and authors' experience. CONCLUSIONS Next-generation sequencing approaches are powerful and require an investment in infrastructure and personnel expertise for effective use; however, the potential for improvement of patient care through faster and more accurate molecular diagnoses is high.
Collapse
|
28
|
Simmon KE, Brown-Elliott BA, Ridge PG, Durtschi JD, Mann LB, Slechta ES, Steigerwalt AG, Moser BD, Whitney AM, Brown JM, Voelkerding KV, McGowan KL, Reilly AF, Kirn TJ, Butler WR, Edelstein PH, Wallace RJ, Petti CA. Mycobacterium chelonae-abscessus complex associated with sinopulmonary disease, Northeastern USA. Emerg Infect Dis 2012; 17:1692-700. [PMID: 21888796 PMCID: PMC3322061 DOI: 10.3201/eid1709.101667] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
29
|
Coonrod EM, Margraf RL, Voelkerding KV. Translating exome sequencing from research to clinical diagnostics. Clin Chem Lab Med 2012; 50:1161-8. [DOI: 10.1515/cclm-2011-0841] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Accepted: 12/01/2011] [Indexed: 11/15/2022]
|
30
|
Margraf RL, Durtschi JD, Dames S, Pattison DC, Stephens JE, Voelkerding KV. Variant identification in multi-sample pools by illumina genome analyzer sequencing. J Biomol Tech 2011; 22:74-84. [PMID: 21738440 PMCID: PMC3121147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Multi-sample pooling and Illumina Genome Analyzer (GA) sequencing allows high throughput sequencing of multiple samples to determine population sequence variation. A preliminary experiment, using the RET proto-oncogene as a model, predicted ≤ 30 samples could be pooled to reliably detect singleton variants without requiring additional confirmation testing. This report used 30 and 50 sample pools to test the hypothesized pooling limit and also to test recent protocol improvements, Illumina GAIIx upgrades, and longer read chemistry. The SequalPrep(TM) method was used to normalize amplicons before pooling. For comparison, a single 'control' sample was run in a different flow cell lane. Data was evaluated by variant read percentages and the subtractive correction method which utilizes the control sample. In total, 59 variants were detected within the pooled samples, which included all 47 known true variants. The 15 known singleton variants due to Sanger sequencing had an average of 1.62 ± 0.26% variant reads for the 30 pool (expected 1.67% for a singleton variant [unique variant within the pool]) and 1.01 ± 0.19% for the 50 pool (expected 1%). The 76 base read lengths had higher error rates than shorter read lengths (33 and 50 base reads), which eliminated the distinction of true singleton variants from background error. This report demonstrated pooling limits from 30 up to 50 samples (depending on error rates and coverage), for reliable singleton variant detection. The presented pooling protocols and analysis methods can be used for variant discovery in other genes, facilitating molecular diagnostic test design and interpretation.
Collapse
|
31
|
Voelkerding KV, Dames S, Durtschi JD. Next generation sequencing for clinical diagnostics-principles and application to targeted resequencing for hypertrophic cardiomyopathy: a paper from the 2009 William Beaumont Hospital Symposium on Molecular Pathology. J Mol Diagn 2011; 12:539-51. [PMID: 20805560 DOI: 10.2353/jmoldx.2010.100043] [Citation(s) in RCA: 96] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
During the past five years, new high-throughput DNA sequencing technologies have emerged; these technologies are collectively referred to as next generation sequencing (NGS). By virtue of sequencing clonally amplified DNA templates or single DNA molecules in a massively parallel fashion in a flow cell, NGS provides both qualitative and quantitative sequence data. This combination of information has made NGS the technology of choice for complex genetic analyses that were previously either technically infeasible or cost prohibitive. As a result, NGS has had a fundamental and broad impact on many facets of biomedical research. In contrast, the dissemination of NGS into the clinical diagnostic realm is in its early stages. Though NGS is powerful and can be envisioned to have multiple applications in clinical diagnostics, the technology is currently complex. Successful adoption of NGS into the clinical laboratory will require expertise in both molecular biology techniques and bioinformatics. The current report presents principles that underlie NGS including sequencing library preparation, sequencing chemistries, and an introduction to NGS data analysis. These concepts are subsequently further illustrated by showing representative results from a case study using NGS for targeted resequencing of genes implicated in hypertrophic cardiomyopathy.
Collapse
|
32
|
Liew M, Wittwer C, Voelkerding KV. Nucleotide extension genotyping by high-resolution melting. J Mol Diagn 2010; 12:731-8. [PMID: 20847280 DOI: 10.2353/jmoldx.2010.090149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
One limitation of small amplicon melting is the inability to genotype certain nearest-neighbor symmetric variations without manipulating the sample. We have developed a method for these exceptions: a high-resolution melting single nucleotide extension assay. Single nucleotide extension was performed in a new instrument, the LightScanner 32 (LS32), which uses capillary reaction tubes and is capable of real-time PCR and sequential high-resolution melting of 32 samples. Asymmetric PCR used Platinum Taq and LC Green Plus in the master mix for target amplification. Dideoxynucleotides and extension oligonucleotides were sequestered in the tube cap and added post-PCR, maintaining a closed system. One dideoxynucleotides was used per capillary tube. Samples were cycled five times to incorporate dideoxynucleotides into the extension products using ThermoSequenase, followed by high-resolution melting. Single nucleotide polymorphisms from the RET proto-oncogene (n = 7), hemochromatosis (HFE, n = 30), coagulation factor 2 (F2, n = 29), coagulation factor 5 (F5, n = 30), and methylenetetrahydrofolate reductase (MTHFR, n = 60) genes were genotyped. The DNA melting profiles identified the target single nucleotide polymorphisms by the lowest melting temperature transition. All genotypes had a distinctive melting pattern. The method was 100% concordant with samples previously genotyped at HFE, MTHFR, and F2 and 90% concordant with F5. F5 discordants were genotyped correctly by redesigning the assay. Our results demonstrate that although single nucleotide polymorphisms can be successfully differentiated using this methodology, the method requires careful optimization.
Collapse
|
33
|
Margraf RL, Durtschi JD, Dames S, Pattison DC, Stephens JE, Mao R, Voelkerding KV. Multi-sample pooling and illumina genome analyzer sequencing methods to determine gene sequence variation for database development. J Biomol Tech 2010; 21:126-140. [PMID: 20808642 PMCID: PMC2922832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Determination of sequence variation within a genetic locus to develop clinically relevant databases is critical for molecular assay design and clinical test interpretation, so multisample pooling for Illumina genome analyzer (GA) sequencing was investigated using the RET proto-oncogene as a model. Samples were Sanger-sequenced for RET exons 10, 11, and 13-16. Ten samples with 13 known unique variants ("singleton variants" within the pool) and seven common changes were amplified and then equimolar-pooled before sequencing on a single flow cell lane, generating 36 base reads. For comparison, a single "control" sample was run in a different lane. After alignment, a 24-base quality score-screening threshold and 3; read end trimming of three bases yielded low background error rates with a 27% decrease in aligned read coverage. Sequencing data were evaluated using an established variant detection method (percent variant reads), by the presented subtractive correction method, and with SNPSeeker software. In total, 41 variants (of which 23 were singleton variants) were detected in the 10 pool data, which included all Sanger-identified variants. The 23 singleton variants were detected near the expected 5% allele frequency (average 5.17%+/-0.90% variant reads), well above the highest background error (1.25%). Based on background error rates, read coverage, simulated 30, 40, and 50 sample pool data, expected singleton allele frequencies within pools, and variant detection methods; >or=30 samples (which demonstrated a minimum 1% variant reads for singletons) could be pooled to reliably detect singleton variants by GA sequencing.
Collapse
|
34
|
Svensson AM, Chou LS, Miller CE, Robles JA, Swensen JJ, Voelkerding KV, Mao R, Lyon E. Detection of large rearrangements in the cystic fibrosis transmembrane conductance regulator gene by multiplex ligation-dependent probe amplification assay when sequencing fails to detect two disease-causing mutations. Genet Test Mol Biomarkers 2010; 14:171-4. [PMID: 20059381 DOI: 10.1089/gtmb.2009.0099] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
AIMS Most of the over 1600 mutations and sequence variants identified to date in the cystic fibrosis transmembrane conductance regulator (CFTR) gene are point mutations or small deletions/insertions detectable by conventional sequencing. However, large rearrangements (deletions, duplications, or insertion/deletion mutations) have recently been reported to constitute 1-2% of CFTR mutations. The CFTR sequencing protocol at ARUP Laboratories interrogates the coding regions of all 27 exons and all intron/exon boundaries of the gene. This study was undertaken to determine whether testing for large gene rearrangements could improve the mutation detection rate. RESULTS Nine cases with abnormal quantitative pilocarpine iontophoresis sweat chloride (SC) values (>60 mEq/L) and 20 cases with borderline SC levels (40-60 mEq/L) with only one or no mutations detected by the ARUP 32 mutation panel, including the 23 mutations recommended by American College of Medical Genetics (ACMG) for carrier screening, followed by sequencing, were tested using a multiplex ligation-dependent probe amplification (MLPA) assay. MLPA analysis identified one deletion among nine patients with SC >60 who had previously been tested with sequencing. None of the cases with borderline SC levels showed rearrangements. CONCLUSION The MLPA assay for detection of large rearrangements may be valuable in individuals with positive SC levels where one or no mutations have been identified by sequencing.
Collapse
|
35
|
Dames S, Durtschi J, Geiersbach K, Stephens J, Voelkerding KV. Comparison of the Illumina Genome Analyzer and Roche 454 GS FLX for resequencing of hypertrophic cardiomyopathy-associated genes. J Biomol Tech 2010; 21:73-80. [PMID: 20592870 PMCID: PMC2884316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Next-generation sequencing (NGS) is widely used in biomedical research, but its adoption has been limited in molecular diagnostics. One application of NGS is the targeted resequencing of genes whose mutations lead to an overlapping clinical phenotype. This study evaluated the comparative performance of the Illumina Genome Analyzer and Roche 454 GS FLX for the resequencing of 16 genes associated with hypertrophic cardiomyopathy (HCM). Using a single human genomic DNA sample enriched by long-range PCR (LR-PCR), 40 GS FLX and 31 Genome Analyzer exon variants were identified using >or=30-fold read-coverage and >or=20% read-percentage selection criteria. Twenty-seven platform concordant variants were Sanger-confirmed. The discordant variants segregated into two categories: variants with read coverages >or=30 on one platform but <30-fold on the alternate platform and variants with read percentages >or=20% on one platform but <20% on the alternate platform. All variants with <30-fold coverage were Sanger-confirmed, suggesting that the coverage criterion of >or=30-fold is too stringent for variant discovery. The variants with <20% read percentage were identified as reference sequence based on Sanger sequencing. These variants were found in homopolymer tracts and short-read misalignments, specifically in genes with high identity. The results of the current study demonstrate the feasibility of combining LR-PCR with the Genome Analyzer or GS FLX for targeted resequencing of HCM-associated genes.
Collapse
|
36
|
Pounder JI, Anderson CM, Voelkerding KV, Salfinger M, Dormandy J, Somoskovi A, Heifets L, Graham JJ, Storts DR, Petti CA. Mycobacterium tuberculosis complex differentiation by genomic deletion patterns with multiplex polymerase chain reaction and melting analysis. Diagn Microbiol Infect Dis 2010; 67:101-5. [DOI: 10.1016/j.diagmicrobio.2009.12.014] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2009] [Revised: 12/04/2009] [Accepted: 12/11/2009] [Indexed: 11/29/2022]
|
37
|
Voelkerding KV, Lyon E. Digital Fetal Aneuploidy Diagnosis by Next-Generation Sequencing. Clin Chem 2010; 56:336-8. [DOI: 10.1373/clinchem.2009.141267] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
38
|
Seipp MT, Durtschi JD, Voelkerding KV, Wittwer CT. Multiplex amplicon genotyping by high-resolution melting. J Biomol Tech 2009; 20:160-164. [PMID: 19568454 PMCID: PMC2700465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
High-resolution amplicon melting is a simple method for genotyping that uses only generic PCR primers and a saturating DNA dye. Multiplex amplicon genotyping has previously been reported in a single color, but two instruments were required: a carousel-based rapid cycler and a high-resolution melting instrument for capillaries. Manual transfer of capillaries between instruments and sequential melting of each capillary at 0.1 degrees C/s seriously limited the throughput. In this report, a single instrument that combines rapid-cycle real-time PCR with high-resolution melting [LightScanner-32 (LS-32), Idaho Technology, Salt Lake City, UT] was used for multiplex amplicon genotyping. The four most common mutations associated with thrombophilia, F5 (factor V Leiden 1691G>A), F2 (prothrombin 20210G>A), and methylenetetrahydrofolate reductase (MTHFR; 1298A>C and 677C>T) were genotyped in a single homogeneous assay with internal controls to adjust for minor chemistry and instrument variation. Forty temperature cycles required 9.2 min, and each capillary required 2.2 min by melting at 0.3 degrees C/s, 3x the prior rate. Sample volume was reduced from 20 microl to 10 microl. In a blinded study of 109 samples (436 genotypes), complete concordance with standard assays was obtained. In addition, the rare variant MTHFR 1317T>C was genotyped correctly when present. The LS-32 simplifies more complex high-resolution melting assays by reducing hands-on manipulation, total time of analysis, and reagent cost while maintaining the resolution necessary for multiplex amplicon genotyping.
Collapse
|
39
|
Voelkerding KV, Dames SA, Durtschi JD. Next-generation sequencing: from basic research to diagnostics. Clin Chem 2009; 55:641-58. [PMID: 19246620 DOI: 10.1373/clinchem.2008.112789] [Citation(s) in RCA: 544] [Impact Index Per Article: 36.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND For the past 30 years, the Sanger method has been the dominant approach and gold standard for DNA sequencing. The commercial launch of the first massively parallel pyrosequencing platform in 2005 ushered in the new era of high-throughput genomic analysis now referred to as next-generation sequencing (NGS). CONTENT This review describes fundamental principles of commercially available NGS platforms. Although the platforms differ in their engineering configurations and sequencing chemistries, they share a technical paradigm in that sequencing of spatially separated, clonally amplified DNA templates or single DNA molecules is performed in a flow cell in a massively parallel manner. Through iterative cycles of polymerase-mediated nucleotide extensions or, in one approach, through successive oligonucleotide ligations, sequence outputs in the range of hundreds of megabases to gigabases are now obtained routinely. Highlighted in this review are the impact of NGS on basic research, bioinformatics considerations, and translation of this technology into clinical diagnostics. Also presented is a view into future technologies, including real-time single-molecule DNA sequencing and nanopore-based sequencing. SUMMARY In the relatively short time frame since 2005, NGS has fundamentally altered genomics research and allowed investigators to conduct experiments that were previously not technically feasible or affordable. The various technologies that constitute this new paradigm continue to evolve, and further improvements in technology robustness and process streamlining will pave the path for translation into clinical diagnostics.
Collapse
|
40
|
Erali M, Voelkerding KV, Wittwer CT. High resolution melting applications for clinical laboratory medicine. Exp Mol Pathol 2008; 85:50-8. [PMID: 18502416 DOI: 10.1016/j.yexmp.2008.03.012] [Citation(s) in RCA: 192] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2008] [Accepted: 03/11/2008] [Indexed: 01/03/2023]
Abstract
Separation of the two strands of DNA with heat (melting) is a fundamental property of DNA that is conveniently monitored with fluorescence. Conventional melting is performed after PCR on any real-time instrument to monitor product purity (dsDNA dyes) and sequence (hybridization probes). Recent advances include high resolution instruments and saturating DNA dyes that distinguish many different species. For example, mutation scanning (identifying heterozygotes) by melting is closed-tube and has similar or superior sensitivity and specificity compared to methods that require physical separation. With high resolution melting, SNPs can be genotyped without probes and more complex regions can be typed with unlabeled hybridization probes. Highly polymorphic HLA loci can be melted to establish sequence identity for transplantation matching. Simultaneous genotyping with one or more unlabeled probes and mutation scanning of the entire amplicon can be performed at the same time in the same tube, vastly decreasing or eliminating the need for re-sequencing in genetic analysis. High resolution PCR product melting is homogeneous, closed-tube, rapid (1-5 min), non-destructive and does not require covalently-labeled fluorescent probes. In the clinical laboratory, it is an ideal format for in-house testing, with minimal cost and time requirements for new assay development.
Collapse
|
41
|
Seipp MT, Pattison D, Durtschi JD, Jama M, Voelkerding KV, Wittwer CT. Quadruplex Genotyping of F5, F2, and MTHFR Variants in a Single Closed Tube by High-Resolution Amplicon Melting. Clin Chem 2008; 54:108-15. [PMID: 17981920 DOI: 10.1373/clinchem.2007.097121] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractBackground: Multiplexed amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, asymmetric PCR, or allele-specific PCR; however, correct differentiation of homozygous mutant and wild-type samples by melting temperature (Tm) analysis requires high-resolution melting analysis and controlled reaction conditions.Methods: We designed 4 amplicons bracketing the F5 [coagulation factor V (proaccelerin, labile factor)] 1691G>A, MTHFR (NADPH) 1298A>C, MTHFR 677C>T, and F2 [coagulation factor II (thrombin)] 20210G>A gene variants to melt at different temperatures by varying amplicon length and adding GC- or AT-rich 5′ tails to selected primers. We used rapid-cycle PCRs with cycles of 19–23 s in the presence of a saturating DNA dye and temperature-correction controls and then conducted a high-resolution melting analysis. Heterozygotes were identified at each locus by curve shape, and homozygous genotypes were assigned by Tm. We blinded samples previously genotyped by other methods before analysis with the multiplex melting assay (n = 110).Results: All samples were correctly genotyped with the exception of 7 MTHFR 1298 samples with atypical melting profiles that could not be assigned. Sequencing revealed that these 5 heterozygotes and 2 homozygotes contained the unexpected sequence variant MTHFR 1317T>C. The use of temperature-correction controls decreased the Tm SD within homozygotes by a mean of 38%.Conclusion: Rapid-cycle PCR with high-resolution melting analysis allows simple and accurate multiplex genotyping to at least a factor of 4.
Collapse
|
42
|
Seipp MT, Durtschi JD, Liew MA, Williams J, Damjanovich K, Pont-Kingdon G, Lyon E, Voelkerding KV, Wittwer CT. Unlabeled oligonucleotides as internal temperature controls for genotyping by amplicon melting. J Mol Diagn 2007; 9:284-9. [PMID: 17591926 PMCID: PMC1899416 DOI: 10.2353/jmoldx.2007.060136] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, or allele-specific polymerase chain reaction. However, correct differentiation of homozygous mutant and wild-type samples by melting temperature (Tm) requires high-resolution melting and closely controlled reaction conditions. When three different DNA extraction methods were used to isolate DNA from whole blood, amplicon Tm differences of 0.03 to 0.39 degrees C attributable to the extractions were observed. To correct for solution chemistry differences between samples, complementary unlabeled oligonucleotides were included as internal temperature controls to shift and scale the temperature axis of derivative melting plots. This adjustment was applied to a duplex amplicon melting assay for the methylenetetrahydrofolate reductase variants 1298A>C and 677C>T. High- and low-temperature controls bracketing the amplicon melting region decreased the Tm SD within homozygous genotypes by 47 to 82%. The amplicon melting assay was 100% concordant to an adjacent hybridization probe (HybProbe) melting assay when temperature controls were included, whereas a 3% error rate was observed without temperature correction. In conclusion, internal temperature controls increase the accuracy of genotyping by high-resolution amplicon melting and should also improve results on lower resolution instruments.
Collapse
|
43
|
Dames S, Margraf RL, Pattison DC, Wittwer CT, Voelkerding KV. Characterization of aberrant melting peaks in unlabeled probe assays. J Mol Diagn 2007; 9:290-6. [PMID: 17591927 PMCID: PMC1899421 DOI: 10.2353/jmoldx.2007.060139] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
An unlabeled probe assay relies on a double-stranded DNA-binding dye to detect and verify target based on amplicon and probe melting. During the development and application of unlabeled probe assays, aberrant melting peaks are sometimes observed that may interfere with assay interpretation. In this report, we investigated the origin of aberrant melting profiles observed in an unlabeled probe assay for exon 10 of the RET gene. It was determined that incomplete 3' blocking of the unlabeled probe allowed polymerase-mediated probe extension resulting in extension products that generated the aberrant melting profiles. This report further examined the blocking ability of the 3' modifications C3 spacer, amino-modified C6, phosphate, inverted dT, and single 3' nucleotide mismatches in unlabeled probe experiments. Although no 3' blocking modifications in these experiments were 100% effective, the amino-modified C6, inverted dT, and C3 spacer provided the best blocking efficiencies (1% or less unblocked), phosphate was not as effective of a block (up to 2% unblocked), and single nucleotide mismatches should be avoided as a 3' blocking modification.
Collapse
|
44
|
Dames S, Pattison DC, Bromley LK, Wittwer CT, Voelkerding KV. Unlabeled probes for the detection and typing of herpes simplex virus. Clin Chem 2007; 53:1847-54. [PMID: 17720894 DOI: 10.1373/clinchem.2007.090761] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Unlabeled probe detection with a double-stranded DNA (dsDNA) binding dye is one method to detect and confirm target amplification after PCR. Unlabeled probes and amplicon melting have been used to detect small deletions and single-nucleotide polymorphisms in assays where template is in abundance. Unlabeled probes have not been applied to low-level target detection, however. METHODS Herpes simplex virus (HSV) was chosen as a model to compare the unlabeled probe method to an in-house reference assay using dual-labeled, minor groove binding probes. A saturating dsDNA dye (LCGreen Plus) was used for real-time PCR. HSV-1, HSV-2, and an internal control were differentiated by PCR amplicon and unlabeled probe melting analysis after PCR. RESULTS The unlabeled probe technique displayed 98% concordance with the reference assay for the detection of HSV from a variety of archived clinical samples (n = 182). HSV typing using unlabeled probes was 99% concordant (n = 104) to sequenced clinical samples and allowed for the detection of sequence polymorphisms in the amplicon and under the probe. CONCLUSIONS Unlabeled probes and amplicon melting can be used to detect and genotype as few as 10 copies of target per reaction, restricted only by stochastic limitations. The use of unlabeled probes provides an attractive alternative to conventional fluorescence-labeled, probe-based assays for genotyping and detection of HSV and might be useful for other low-copy targets where typing is informative.
Collapse
|
45
|
Durtschi JD, Stevenson J, Hymas W, Voelkerding KV. Evaluation of quantification methods for real-time PCR minor groove binding hybridization probe assays. Anal Biochem 2007; 361:55-64. [PMID: 17188229 DOI: 10.1016/j.ab.2006.11.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2006] [Revised: 11/11/2006] [Accepted: 11/14/2006] [Indexed: 11/19/2022]
Abstract
Real-time PCR data analysis for quantification has been the subject of many studies aimed at the identification of new and improved quantification methods. Several analysis methods have been proposed as superior alternatives to the common variations of the threshold crossing method. Notably, sigmoidal and exponential curve fit methods have been proposed. However, these studies have primarily analyzed real-time PCR with intercalating dyes such as SYBR Green. Clinical real-time PCR assays, in contrast, often employ fluorescent probes whose real-time amplification fluorescence curves differ from those of intercalating dyes. In the current study, we compared four analysis methods related to recent literature: two versions of the threshold crossing method, a second derivative maximum method, and a sigmoidal curve fit method. These methods were applied to a clinically relevant real-time human herpes virus type 6 (HHV6) PCR assay that used a minor groove binding (MGB) Eclipse hybridization probe as well as an Epstein-Barr virus (EBV) PCR assay that used an MGB Pleiades hybridization probe. We found that the crossing threshold method yielded more precise results when analyzing the HHV6 assay, which was characterized by lower signal/noise and less developed amplification curve plateaus. In contrast, the EBV assay, characterized by greater signal/noise and amplification curves with plateau regions similar to those observed with intercalating dyes, gave results with statistically similar precision by all four analysis methods.
Collapse
|
46
|
Herrmann MG, Durtschi JD, Bromley LK, Wittwer CT, Voelkerding KV. Instrument Comparison for Heterozygote Scanning of Single and Double Heterozygotes: A Correction and Extension of Herrmann et al., Clin Chem 2006;52:494-503. Clin Chem 2007; 53:150-2. [PMID: 17202505 DOI: 10.1373/clinchem.2006.081240] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
47
|
Dames S, Bromley LK, Herrmann M, Elgort M, Erali M, Smith R, Voelkerding KV. A single-tube nucleic acid extraction, amplification, and detection method using aluminum oxide. J Mol Diagn 2006; 8:16-21. [PMID: 16436630 PMCID: PMC1867575 DOI: 10.2353/jmoldx.2006.040398] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A disposable 0.2-ml polymerase chain reaction (PCR) tube modified with an aluminum oxide membrane (AOM) has been developed for the extraction, amplification, and detection of nucleic acids. To assess the dynamic range of AOM tubes for real-time PCR, quantified herpes simplex virus (HSV) DNA was used to compare AOM tubes to standard PCR tubes. AOM PCR tubes used for amplification and detection of quantified HSV-1 displayed a crossing threshold (C(T)) shift 0.1 cycles greater than PCR tube controls. Experiments with HSV-1-positive cerebrospinal fluid (CSF) examined the extraction, amplification, and detection properties of the AOM tubes compared to the Qiagen DNA blood mini kit. The AOM extraction, amplification, and detection of HSV-1 in CSF displayed differences of less than one C(T) when compared to Qiagen-extracted samples. Experiments testing the AOM method using clinical CSF samples displayed 100% concordance with reported results. AOM tubes have no adverse effects on amplification or fluorescence acquisition by real-time PCR and can be effectively used for the extraction, amplification, and detection of HSV from CSF. The AOM single tube method is a fast, reliable, and reproducible technique for the extraction, amplification, and detection of HSV in CSF.
Collapse
|
48
|
Herrmann MG, Durtschi JD, Bromley LK, Wittwer CT, Voelkerding KV. Amplicon DNA Melting Analysis for Mutation Scanning and Genotyping: Cross-Platform Comparison of Instruments and Dyes. Clin Chem 2006; 52:494-503. [PMID: 16423901 DOI: 10.1373/clinchem.2005.063438] [Citation(s) in RCA: 198] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Background: DNA melting analysis for genotyping and mutation scanning of PCR products by use of high-resolution instruments with special “saturation” dyes has recently been reported. The comparative performance of other instruments and dyes has not been evaluated.
Methods: A 110-bp fragment of the β-globin gene including the sickle cell anemia locus (A17T) was amplified by PCR in the presence of either the saturating DNA dye, LCGreen Plus, or SYBR Green I. Amplicons of 3 different genotypes (wild-type, heterozygous, and homozygous mutants) were melted on 9 different instruments (ABI 7000 and 7900HT, Bio-Rad iCycler, Cepheid SmartCycler, Corbett Rotor-Gene 3000, Idaho Technology HR-1 and LightScanner, and the Roche LightCycler 1.2 and LightCycler 2.0) at a rate of 0.1 °C/s or as recommended by the manufacturer. The ability of each instrument/dye combination to genotype by melting temperature (Tm) and to scan for heterozygotes by curve shape was evaluated.
Results: Resolution varied greatly among instruments with a 15-fold difference in Tm SD (0.018 to 0.274 °C) and a 19-fold (LCGreen Plus) or 33-fold (SYBR Green I) difference in the signal-to-noise ratio. These factors limit the ability of most instruments to accurately genotype single-nucleotide polymorphisms by amplicon melting. Plate instruments (96-well) showed the greatest variance with spatial differences across the plates. Either SYBR Green I or LCGreen Plus could be used for genotyping by Tm, but only LCGreen Plus was useful for heterozygote scanning. However, LCGreen Plus could not be used on instruments with an argon laser because of spectral mismatch. All instruments compatible with LCGreen Plus were able to detect heterozygotes by altered melting curve shape. However, instruments specifically designed for high-resolution melting displayed the least variation, suggesting better scanning sensitivity and specificity.
Conclusion: Different instruments and dyes vary widely in their ability to genotype homozygous variants and scan for heterozygotes by whole-amplicon melting analysis.
Collapse
|
49
|
Durtschi JD, Erali M, Bromley LK, Herrmann MG, Petti CA, Smith RE, Voelkerding KV. Increased sensitivity of bacterial detection in cerebrospinal fluid by fluorescent staining on low-fluorescence membrane filters. J Med Microbiol 2005; 54:843-850. [PMID: 16091435 DOI: 10.1099/jmm.0.46092-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
A membrane-filter-based, fluorescent Gram stain method for bacterial detection in cerebrospinal fluid samples was developed and evaluated as a rapid, sensitive alternative to standard Gram stain protocols. A recently developed, modified version of the aluminium oxide membrane Anopore with low-fluorescence optical properties showed superior performance in this application. Other aspects of the fluorescent Gram stain system that were evaluated include membrane filter selection, strategies to reduce fluorescence fading and the effect of patient blood cells on bacterial detection in the fluorescently stained cerebrospinal fluid samples. The combination of the membrane filter's bacteria-concentrating ability and absolute retention along with high-contrast, fluorescent Gram discriminating dyes enabled rapid bacterial detection and Gram discrimination, with a 1-1.5 order of magnitude increase in the bacterial concentration limit of detection.
Collapse
|
50
|
Durtschi JD, Erali M, Herrmann MG, Elgort MG, Voelkerding KV, Smith RE. Optically improved aluminum oxide membrane through electroless Ni modification. J Memb Sci 2005. [DOI: 10.1016/j.memsci.2004.09.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|