26
|
von Segesser LK, Ferrari E, Tozzi P, Abdel-Sayed S, Berdajs D. Late removal of retrievable caval filters. Swiss Med Wkly 2014; 144:w14022. [PMID: 25375823 DOI: 10.4414/smw.2014.14022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.
Collapse
|
27
|
Li L, Abdel-Sayed S, Berdajs D, Ferrari E, von Segesser LK. Venous cannula performance assessment in a realistic caval tree model. Interact Cardiovasc Thorac Surg 2014; 20:194-9. [DOI: 10.1093/icvts/ivu318] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
28
|
Mosbahi S, Mickaily-Huber E, Charbonnier D, Hullin R, Burki M, Ferrari E, von Segesser LK, Berdajs DA. Computational fluid dynamics of the right ventricular outflow tract and of the pulmonary artery: a bench model of flow dynamics. Interact Cardiovasc Thorac Surg 2014; 19:611-6. [DOI: 10.1093/icvts/ivu202] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
29
|
von Segesser LK, Beyersdorf F. Impact Factor 1.112 for Interactive CardioVascular and Thoracic Surgery: a well-deserved recognition for all contributors. Interact Cardiovasc Thorac Surg 2014; 17:601-2. [PMID: 24065748 DOI: 10.1093/icvts/ivt393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
30
|
Berdajs DA, Muradbegovic M, Haselbach D, Kofmehl R, Steurer J, Ferrari E, Held U, von Segesser LK. Ross procedure: is the root replacement technique superior to the sub-coronary implantation technique? Long-term results. Eur J Cardiothorac Surg 2014; 46:944-51. [DOI: 10.1093/ejcts/ezu176] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
31
|
von Segesser LK. Peripheral cannulation for cardiopulmonary bypass. Multimed Man Cardiothorac Surg 2014; 2006:mmcts.2005.001610. [PMID: 24413332 DOI: 10.1510/mmcts.2005.001610] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Peripheral cannulation is the historical route for connecting the pump-oxygenator to the vasculature of the patient in order to establish partial or complete cardiopulmonary bypass. Although most open heart procedures are nowadays realized with central cannulation, there is renewed interest in remote cannulation through the femoral, iliac, axillary, subclavian and jugular vessels. Remote cannulation is not only of interest in hemodynamically unstable patients who can be put on cardiopulmonary bypass in local anesthesia, and stabilized prior to intubation, but also for complex procedures like replacement of the thoracoabdominal aorta, acute type A aortic dissections, complex redo open heart surgery, extracorporeal membrane oxygenation, and more recently, small access open heart surgery, robotic surgery, and others. In the following shall be described femoral arterial cannulation with standard cannulas, femoral arterial cannulation with percutaneous cannulas, femoral venous cannulation using standard cannulas, femoral venous cannulation using percutaneous cannulas, as well as optimized venous cannulation relying on more advanced cannula designs.
Collapse
|
32
|
von Segesser LK, Beyersdorf F. Corrigendum to “Impact Factor 1.112 for Interactive CardioVascular and Thoracic Surgery: a well-deserved recognition for all contributors” [Interact CardioVasc Thorac Surg 17 (2013) 601–602]. Interact Cardiovasc Thorac Surg 2013. [DOI: 10.1093/icvts/ivt497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
33
|
Milano G, Abruzzo PM, Bolotta A, Marini M, Terraneo L, Ravara B, Gorza L, Vitadello M, Burattini S, Curzi D, Falcieri E, von Segesser LK, Samaja M. Impact of the phosphatidylinositide 3-kinase signaling pathway on the cardioprotection induced by intermittent hypoxia. PLoS One 2013; 8:e76659. [PMID: 24124584 PMCID: PMC3790757 DOI: 10.1371/journal.pone.0076659] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Accepted: 08/26/2013] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Exposure to intermittent hypoxia (IH) may enhance cardiac function and protects heart against ischemia-reperfusion (I/R) injury. To elucidate the underlying mechanisms, we developed a cardioprotective IH model that was characterized at hemodynamic, biochemical and molecular levels. METHODS Mice were exposed to 4 daily IH cycles (each composed of 2-min at 6-8% O2 followed by 3-min reoxygenation for 5 times) for 14 days, with normoxic mice as controls. Mice were then anesthetized and subdivided in various subgroups for analysis of contractility (pressure-volume loop), morphology, biochemistry or resistance to I/R (30-min occlusion of the left anterior descending coronary artery (LAD) followed by reperfusion and measurement of the area at risk and infarct size). In some mice, the phosphatidylinositide 3-kinase (PI3K) inhibitor wortmannin was administered (24 µg/kg ip) 15 min before LAD. RESULTS We found that IH did not induce myocardial hypertrophy; rather both contractility and cardiac function improved with greater number of capillaries per unit volume and greater expression of VEGF-R2, but not of VEGF. Besides increasing the phosphorylation of protein kinase B (Akt) and the endothelial isoform of NO synthase with respect to control, IH reduced the infarct size and post-LAD proteins carbonylation, index of oxidative damage. Administration of wortmannin reduced the level of Akt phosphorylation and worsened the infarct size. CONCLUSION We conclude that the PI3K/Akt pathway is crucial for IH-induced cardioprotection and may represent a viable target to reduce myocardial I/R injury.
Collapse
|
34
|
Colombier S, Kessler U, Ferrari E, von Segesser LK, Berdajs DA. Influence of deep sternal wound infection on long-term survival after cardiac surgery. Med Sci Monit 2013; 19:668-73. [PMID: 23942043 PMCID: PMC3747019 DOI: 10.12659/msm.889191] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background This study aimed to investigate the influence of deep sternal wound infection on long-term survival following cardiac surgery. Material/Methods In our institutional database we retrospectively evaluated medical records of 4732 adult patients who received open-heart surgery from January 1995 through December 2005. The predictive factors for DSWI were determined using logistic regression analysis. Then, each patient with deep sternal wound infection (DSWI) was matched with 2 controls without DSWI, according to the risk factors identified previously. After checking balance resulting from matching, short-term mortality was compared between groups using a paired test, and long-term survival was compared using Kaplan-Meier analysis and a Cox proportional hazard model. Results Overall, 4732 records were analyzed. The mean age of the investigated population was 69.3±12.8 years. DSWI occurred in 74 (1.56%) patients. Significant independent predictive factors for deep sternal infections were active smoking (OR 2.19, CI95 1.35–3.53, p=0.001), obesity (OR 1.96, CI95 1.20–3.21, p=0.007), and insulin-dependent diabetes mellitus (OR 2.09, CI95 1.05–10.06, p=0.016). Mean follow-up in the matched set was 125 months, IQR 99–162. After matching, in-hospital mortality was higher in the DSWI group (8.1% vs. 2.7% p=0.03), but DSWI was not an independent predictor of long-term survival (adjusted HR 1.5, CI95 0.7–3.2, p=0.33). Conclusions The results presented in this report clearly show that post-sternotomy deep wound infection does not influence long-term survival in an adult general cardio-surgical patient population.
Collapse
|
35
|
von Segesser LK, Gerosa G, Borger MA, Ferrari E. Prevention and management of potential adverse events during transapical aortic valve replacement. THE JOURNAL OF HEART VALVE DISEASE 2013; 22:276-286. [PMID: 24151752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
BACKGROUND AND AIM OF THE STUDY Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.
Collapse
|
36
|
Roumy A, de Leval L, Niclauss L, Schaefer SC, Kurtin P, Dogan A, von Segesser LK, Ruchat P. Localized amyloid light-chain amyloidosis and extramedullary plasmacytoma of the mitral valve. Ann Thorac Surg 2013; 95:1782-4. [PMID: 23608260 DOI: 10.1016/j.athoracsur.2012.08.085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2012] [Revised: 05/20/2012] [Accepted: 08/20/2012] [Indexed: 10/26/2022]
Abstract
An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.
Collapse
|
37
|
von Segesser LK. EACTS Presidential Address: the contraindications of today are the indications of tomorrow. Eur J Cardiothorac Surg 2013; 43:665-72. [PMID: 23509340 DOI: 10.1093/ejcts/ezt049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
38
|
Tozzi P, Locca D, Gronchi F, Hayoz D, Ferrari E, von Segesser LK, Hullin R. Active mitral ring for post-surgical remote correction of residual mitral regurgitation on the beating heart. Eur J Cardiothorac Surg 2013; 44:370-4; discussion 374. [PMID: 23386714 DOI: 10.1093/ejcts/ezs710] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Collapse
|
39
|
Schaakxs D, Fumeaux A, von Segesser LK, Berdajs DA. Abdominal aorta infection by Streptococcus pyogenes. Eur J Cardiothorac Surg 2013; 43:e48. [PMID: 23302129 DOI: 10.1093/ejcts/ezs593] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
40
|
|
41
|
Abstract
There is no doubt that the European Association for Cardio-Thoracic Surgery is a success story. In 2011, we celebrated the 25th anniversary of this professional organization. In 2012, we will celebrate the 25th anniversary of the European Journal of Cardio-Thoracic Surgery. In addition, two other journals have been initiated, Interactive CardioVascular and Thoracic Surgery and the Multimedia Manual of Cardio-Thoracic Surgery, and all of them can be accessed through CTSnet (www.ctsnet.org). The most recent development was the birth of EACTS House, and it was to celebrate the official opening of EACTS House on 10 February 2011, that we held the second Strategic meeting, 'EACTS in the Future'. On this occasion, the EACTS council and delegates of the EACTS Domains (Domain of Thoracic Disease, Domain of Vascular Disease, Domain of Congenital Cardiac Disease and Domain of Adult Cardiac Disease) came together with representative thoracic and cardio-vascular surgeons from North America, Asia and BRICS countries as well as senior managers from industry in order to decide where to go from there. As a basis for starting the discussions, a sector analysis of the activities of the Department of Cardio-Vascular Surgery at CHUV in Lausanne, Switzerland was performed in order to identify the trends in the activities of our group of surgeons by pulling the consolidated data for the period running from 1 January 1995 to 31 December 2010. Interestingly enough, the most frequent procedures like coronary artery bypass graft and valve repair/replacement did not increase despite a growing programme. In our setting, the compensation came mainly from vascular surgery and mechanical circulatory support. These data have to be put in perspective by the reports provided by the EACTS domain chairs in order to identify the challenges and opportunities for the future development of our specialties.
Collapse
|
42
|
Berdajs D, Marinakis S, Kessler U, Muradbegovic M, Ferrari E, von Segesser LK. Impaired left ventricular function as a predictive factor for mid-term survival in octogenarians after primary coronary artery bypass surgery. Swiss Med Wkly 2012; 142:w13704. [PMID: 23135871 DOI: 10.4414/smw.2012.13704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The impact of preoperative impaired left ventricular ejection fraction (EF) in octogenarians following coronary bypass surgery on short-term survival was evaluated in this study. METHODS A total of 147 octogenarians (mean age 82.1 ± 1.9 years) with coronary artery diseases underwent elective coronary artery bypass graft between January 2000 and December 2009. Patients were stratified into: Group I (n = 59) with EF >50%, Group II (n = 59) with 50% > EF >30% and in Group III (n = 29) with 30% > EF. RESULTS There was no difference among the three groups regarding incidence of COPD, renal failure, congestive heart failure, diabetes, and preoperative cerebrovascular events. Postoperative atrial fibrillation was the sole independent predictive factor for in-hospital mortality (odds ratio (OR), 18.1); this was 8.5% in Group I, 15.3% in Group II and 10.3% in Group III. Independent predictive factors for mortality during follow up were: decrease of EF during follow-up for more that 5% (OR, 5.2), usage of left internal mammary artery as free graft (OR, 18.1), and EF in follow-up lower than 40% (OR, 4.8). CONCLUSIONS The results herein suggest acceptable in-hospital as well short-term mortality in octogenarians with impaired EF following coronary artery bypass grafting (CABG) and are comparable to recent literature where the mortality of younger patients was up to 15% and short-term mortality up to 40%, respectively. Accordingly, we can also state that in an octogenarian cohort with impaired EF, CABG is a viable treatment with acceptable mortality.
Collapse
|
43
|
von Segesser LK, Beyersdorf F. Ten years of Interactive CardioVascular and Thoracic Surgery. Interact Cardiovasc Thorac Surg 2012; 15:571-3. [PMID: 22991391 PMCID: PMC3445405 DOI: 10.1093/icvts/ivs406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
44
|
Sekarski N, Hurni M, von Segesser LK, Meijboom EJ, Di Bernardo S. Adaptable Pulmonary Artery Band for Late Arterial Switch Procedure in Transposition of the Great Arteries. Ann Thorac Surg 2012; 94:1311-6. [DOI: 10.1016/j.athoracsur.2012.04.095] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2012] [Revised: 04/23/2012] [Accepted: 04/26/2012] [Indexed: 10/27/2022]
|
45
|
Zou Y, Ferrari E, von Segesser LK. Off-pump transapical mitral valve-in-ring implantation. Eur J Cardiothorac Surg 2012; 43:849-55. [PMID: 22822106 DOI: 10.1093/ejcts/ezs407] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM™). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT™) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.
Collapse
|
46
|
Vottero GV, Niclauss L, Marcucci C, Hurni M, von Segesser LK. Late Migration of Percutaneous Bio-Absorbable Devices-A Word of Caution. J Card Surg 2011; 27:183-5. [DOI: 10.1111/j.1540-8191.2011.01357.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
47
|
Milano G, Bianciardi P, Rochemont V, Vassalli G, Segesser LKV, Corno AF, Guazzi M, Samaja M. Phosphodiesterase-5 inhibition mimics intermittent reoxygenation and improves cardioprotection in the hypoxic myocardium. PLoS One 2011; 6:e27910. [PMID: 22140481 PMCID: PMC3225385 DOI: 10.1371/journal.pone.0027910] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2011] [Accepted: 10/27/2011] [Indexed: 12/04/2022] Open
Abstract
Although chronic hypoxia is a claimed myocardial risk factor reducing tolerance to ischemia/reperfusion (I/R), intermittent reoxygenation has beneficial effects and enhances heart tolerance to I/R. Aim of the study: To test the hypothesis that, by mimicking intermittent reoxygenation, selective inhibition of phosphodiesterase-5 activity improves ischemia tolerance during hypoxia. Adult male Sprague-Dawley rats were exposed to hypoxia for 15 days (10% O2) and treated with placebo, sildenafil (1.4 mg/kg/day, i. p.), intermittent reoxygenation (1 h/day exposure to room air) or both. Controls were normoxic hearts. To assess tolerance to I/R all hearts were subjected to 30-min regional ischemia by left anterior descending coronary artery ligation followed by 3 h-reperfusion. Whereas hypoxia depressed tolerance to I/R, both sildenafil and intermittent reoxygenation reduced the infarct size without exhibiting cumulative effects. The changes in myocardial cGMP, apoptosis (DNA fragmentation), caspase-3 activity (alternative marker for cardiomyocyte apoptosis), eNOS phosphorylation and Akt activity paralleled the changes in cardioprotection. However, the level of plasma nitrates and nitrites was higher in the sildenafil+intermittent reoxygenation than sildenafil and intermittent reoxygenation groups, whereas total eNOS and Akt proteins were unchanged throughout. Conclusions: Sildenafil administration has the potential to mimic the cardioprotective effects led by intermittent reoxygenation, thereby opening the possibility to treat patients unable to be reoxygenated through a pharmacological modulation of NO-dependent mechanisms.
Collapse
|
48
|
Berdajs DA, de Stefano E, Delay D, Ferrari E, Horisberger J, Ditmar Q, von Segesser LK. The new advanced membrane gas exchanger. Interact Cardiovasc Thorac Surg 2011; 13:591-6. [PMID: 21835847 DOI: 10.1510/icvts.2011.276873] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Current membrane oxygenators are constructed for patients with a body surface under 2.2 m(2). If the body surface exceeds 2.5 m(2), commercially available devices may not allow adequate oxygenation during cardiopulmonary bypass. To address this, a hollow-fiber oxygenator with an enlarged contact surface of 1.81 m(2) was tested. In an experimental set-up, six calves of mean weight 85.4 ± 3 kg were connected to cardiopulmonary bypass. They were randomly assigned to a standard oxygenator (n = 3; ADMIRAL, Euroset, Medola, Italy) with a surface of 1.35 m(2) or to an enlarged surface oxygenator (n = 3; AMG, Euroset). Blood samples were taken before bypass, after 10 min on bypass, and after 1, 2, 5 and 6 h of perfusion. Analysis of variance was used for repeated measurements. The mean flow rate was 6.5 l/min for 6 h. The total oxygen transfer at 6 h was significantly higher in the high-surface group (P < 0.05). Blood trauma, evaluated by plasma hemoglobin and lactate dehydrogenase levels, did not detect any significant hemolysis. Thrombocytes and white blood cell count profiles showed no significant differences between the two groups at 6 h of perfusion (P = 0.06 and 0.80, respectively). At the end of testing, no clot deposition was found in the oxygenator, and there was no evidence of peripheral emboli. The results suggest that the new oxygenator allows very good gas transfer and may be used for patients with a large body surface area.
Collapse
|
49
|
Berdajs D, Ruchat P, Suva M, Ferrari E, Ligang L, von Segesser LK. Congenital giant aneurysm of the left coronary artery. Heart Lung Circ 2011; 20:663-5. [PMID: 21478051 DOI: 10.1016/j.hlc.2011.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Revised: 01/24/2011] [Accepted: 02/14/2011] [Indexed: 11/27/2022]
Abstract
We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.
Collapse
|
50
|
Rolf T, Iglesias JF, Qanadli SD, Hurni M, von Segesser LK. Complication of carotid stenting: incomplete misdeployment of the stent in the femoral artery. Interact Cardiovasc Thorac Surg 2011; 13:58-9. [PMID: 21451089 DOI: 10.1510/icvts.2010.263061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVES The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.
Collapse
|