26
|
Shimatani Y, Tsujimoto A, Barkmeier WW, Fischer NG, Nagura Y, Takamizawa T, Latta MA, Miyazaki M. Simulated Cuspal Deflection and Flexural Properties of Bulk-Fill and Conventional Flowable Resin Composites. Oper Dent 2020; 45:537-546. [PMID: 32216724 DOI: 10.2341/18-160-l] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/17/2018] [Indexed: 11/23/2022]
Abstract
CLINICAL RELEVANCE Some bulk-fill flowable resin composites produce less cuspal deflection than a conventional incrementally filled flowable resin composites. SUMMARY Objective: This study investigated simulated cuspal deflection and flexural properties of bulk-fill and conventional flowable resin composites.Methods and Materials: Five bulk-fill and six conventional flowable resin composites were evaluated. Aluminium blocks with a mesio-occlusal-distal cavity were prepared and randomly divided into groups for each of the different measurement techniques and were further subdivided according to the type of flowable resin composite. The simulated cuspal deflection caused by the polymerization of resin composite within an aluminium block was measured using a highly accurate submicron digimatic micrometer or a confocal laser scanning microscope (CLSM). In addition, the flexural properties of tested resin composites were measured to investigate the relation between cuspal deflection and flexural properties, and the resin composites were observed using scanning electron microscopy.Results: Simulated cuspal deflection of some bulk-fill flowable resin composites was found to be significantly lower than or similar to those for conventional counterparts, regardless of the measurement method. There were statistically significant differences in flexural properties depending on the material, regardless of the type of flowable resin composite. Pearson correlation analysis did not reveal a statistically significant relationship between flexural properties and cuspal deflection.Conclusion: These results indicate that some bulk-fill flowable resin composites exhibit lower cuspal deflection with the bulk-filling technique than is shown by conventional flowable resin composites using the incremental filling technique. Simulated cuspal deflection can be measured using either a micrometer or CLSM, but this experiment failed to show a significant relationship between cuspal deflection and flexural properties of flowable resin composites.
Collapse
|
27
|
Fukuhara T, Saito H, Furuya N, Watanabe K, Sugawara S, Iwasawa S, Tsunezuka Y, Yamaguchi O, Okada PM, Yoshimori K, Nakachi I, Gemma PA, Azuma K, Kurimoto F, Tsubata Y, Fujita Y, Nagashima H, Asai G, Watanabe S, Miyazaki M, Hagiwara PK, Nukiwa PT, Morita PS, Kobayashi PK, Maemondo PM. Evaluation of plasma EGFR mutation as an early predictor of response of erlotinib plus bevacizumab treatment in the NEJ026 study. EBioMedicine 2020; 57:102861. [PMID: 32629391 PMCID: PMC7334809 DOI: 10.1016/j.ebiom.2020.102861] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 05/24/2020] [Accepted: 06/11/2020] [Indexed: 12/26/2022] Open
Abstract
Background The NEJ026 Phase 3 study demonstrated that erlotinib and bevacizumab (BE)-treated NSCLC patients with EGFR mutations had significantly better progression-free survival (PFS) than those treated with erlotinib alone (E). This study included a prospective analysis of the relationship between the mutational status of EGFR in plasma circulating tumor DNA (ctDNA) and the efficacy of TKI monotherapy or combination therapy. We describe these results herein. Methods Plasma samples were collected from patients enrolled in NEJ026 at the start of treatment (P0), 6 weeks after the start of treatment (P1), and upon confirmation of progressive disease (P2). Plasma ctDNA was analyzed using a modified PNA-LNA PCR clamp method. PFS and OS according to EGFR status at the time of plasma collection were evaluated. Findings Plasma activating EGFR mutation (aEGFR) at P0 was detected in 68% of cases; patients without plasma aEGFR had longer PFS. The frequency of T790M mutation at P2 was similar in both arms: 8 (19.0%) in BE and 11 (20.8%) in E. Based on the aEGFR profiles, PFS was evaluated among three groups: type A [P0(-), P1(-)], type B [P0(+), P1(-)], and type C [P0(+), P1(+)]. This revealed that BE was more efficacious than E, and that BE was associated with improved PFS in all types. Interpretation Pre-treatment plasma aEGFR status have a potential of early predictor of response of TKI efficacy. Monitoring plasma aEGFR mutation will contribute to selection and continuation of treatment with BE or E. Funding Chugai Pharmaceutical.
Collapse
|
28
|
Inoue K, Misaki K, Dobashi N, Miyazaki M, Mako Y, Yusuke T, Imaizumi Y. AB0381 THE UTILITY OF HYDROXYCHLOROQUINE (HCQ) THERAPY FOR TWO YEARS AS A SPARING CORTICOSTEROID AGENCY IN PATIENTS WITH SYSTEMIC LUPUS ERYTHEMATOSUS (SLE). Ann Rheum Dis 2020. [DOI: 10.1136/annrheumdis-2020-eular.5277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Background:Prednisolone (PSL) and HCQ are key drugs in the therapy of SLE. However, since PSL induce many harmful adverse events, PSL is preferred to be reduced especially in the maintenance therapy. The efficacy of HCQ for reducing the dose of PSL has not been revealed yet. So, we focused on the cessation of PSL under the treatment of HCQ with conventional SLE therapy.Objectives:The aim of this study is to evaluate the efficacy and the safety of HCQ as co-treatment in the standard therapy of SLE.Methods:SLE patients (n=30) under the maintenance therapy were enrolled in this study. Dose of PSL, titer of anti-DNA antibody, WBC count, serum complement and SLE disease activity index (SLEDAI) were examined retrospectively at 0 and 12 months after administration of HCQ.Results:Baseline patient-characteristics are as follows (mean±S.E); the age of patients was 54.4±3.2 years old, 21 patients (70%) were female, the disease duration was 108.5±25.2 months, SLEDAI was 4.0±0.9, the dose of PSL was 10.3±1.7 mg/day, the titer of anti-DNA antibody was 7.3±1.8 IU/ml, C3 was 85±4.3 mg/dl and C4 was 18±1.6 mg/dl.The mean dose of PSL was reduced with statistically significance (pre-administration of HCQ:10.3±1.7 mg/day, 24 months after administration of HCQ:2.2±0.3 mg/day,p<0.0001). Furthermore, in this observation period, 6 patients could achieve the cessation of PSL.SLEDAI was also significantly reduced (4.0±0.9 vs 1.0±0.3,p<0.01).There was no statistical significance between before treatment by HCQ and after treatment in the titer of anti-DNA antibody (7.3±1.8 vs 2.8±1.6 IU/ml,p=0.06), WBC count (6208±4.9 vs 5096±3.3 /μl,p=0.06) and serum complement level (C3 85±4.3 mg/dl vs 89±4.0 mg/dl,p=0.52, C4 18±1.6 mg/dl vs 19±1.4 mg/dl,p=0.45). Relapse of SLE was clarified in only one patient.As for adverse events (AEs), Severe bacterial infection (n=4), herpes zoster (n=1) and patellar tendon rupture (n=1) were revealed. All cases of the AEs were fully recovered.Conclusion:Our study suggested that co-treatment with HCQ on standard SLE therapy could be enable to prevent the flare of SLE and reduce the dose of PSL with statistical significance. In some cases, we could achieve the cessation of PSL treatment.References:None.Disclosure of Interests:None declared
Collapse
|
29
|
Nagasawa M, Tomimatsu K, Terada K, Kondo K, Miyazaki K, Miyazaki M, Motooka D, Okuzaki D, Yoshida T, Kageyama S, Kawamoto H, Kawauchi A, Agata Y. Long non-coding RNA MANCR is a target of BET bromodomain protein BRD4 and plays a critical role in cellular migration and invasion abilities of prostate cancer. Biochem Biophys Res Commun 2020; 526:128-134. [PMID: 32199616 DOI: 10.1016/j.bbrc.2020.03.043] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Accepted: 03/09/2020] [Indexed: 01/03/2023]
Abstract
Androgen receptor (AR)-negative castration-resistant prostate cancer (CRPC) is highly aggressive and is resistant to most of the current therapies. Bromodomain and extra terminal domain (BET) protein BRD4 binds to super-enhancers (SEs) that drive high expression of oncogenes in many cancers. A BET inhibitor, JQ1, has been found to suppress the malignant phenotypes of prostate cancer cells, however, the target genes of JQ1 remain largely unknown. Here we show that SE-associated genes specific for AR-negative CRPC PC3 cells include genes involved in migration and invasion, and that JQ1 impairs migration and invasion of PC3 cells. We identified a long non-coding RNA, MANCR, which was markedly down-regulated by JQ1, and found that BRD4 binds to the MANCR locus. MANCR knockdown led to a significant decrease in migration and invasion of PC3 cells. Furthermore, RNA sequencing analysis revealed that expression of the genes involved in migration and invasion was altered by MANCR knockdown. In summary, our data demonstrate that MANCR plays a critical role in migration and invasion of PC3 cells.
Collapse
|
30
|
Yokouchi H, Takabatake H, Ebisui C, Miyazaki M, Tetsumoto S, Higami Y, Tsuda M, Miyao Y, Mori H. [Analysis of Post-Recurrence Survival of Resected Lung Cancer with Brain Metastasis]. Gan To Kagaku Ryoho 2019; 46:2276-2278. [PMID: 32156903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
METHODS We retrospectively evaluated the post-recurrence survival of 37 cases with brain metastases out of 439 consecutive resected cases of primary lung cancer between 2001 and 2017. FINDINGS There was no difference in survival according to tumor size but survival was significantly shorter in patients with larger numbers of tumors. Patients initially treated with stereotactic radiosurgery(SRS)or surgical resection survived longer than those with whole-brain irradiation(WBI)(median survival: 23 months for SRS, 17 months for surgical resection, and 4 months for WBI: p<0.001 between SRS and WBI). CONCLUSIONS As SRS is recommended for 1-4 tumors with maximum diameters ofC3 cm and surgical resection is recommended for tumors larger than 3 cm, these effective locoregional therapies should be aggressively adopted for local control of brain metastases with the aim of improved QOL and prolonged survival. Due to the deterioration of neurocognitive function, WBI should be avoided as initial treatment for brain metastases when effective locoregional therapy or systemic chemotherapy is available and reserved for leptomeningeal dissemination or miliary metastases.
Collapse
|
31
|
Matsuda KM, Koguchi A, Toyama T, Sakuishi K, Kobayashi M, Miura S, Miyazaki M, Suga H, Asano Y, Toda T, Sato S. Concurrence of polyarteritis nodosa and multiple sclerosis. J Eur Acad Dermatol Venereol 2019; 34:e188-e191. [PMID: 31769115 DOI: 10.1111/jdv.16107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
32
|
Ouchi H, Takamizawa T, Tsubota K, Tsujimoto A, Imai A, Barkmeier WW, Latta MA, Miyazaki M. The Effects of Aluminablasting on Bond Durability Between Universal Adhesives and Tooth Substrate. Oper Dent 2019; 45:196-208. [PMID: 31738692 DOI: 10.2341/18-170-l] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to determine the effect of aluminablasting on the bond durability of universal adhesives and adherent surface characteristics. Adhese Universal (Ivoclar Vivadent), All-Bond Universal (Bisco), Bondmer Lightless (Tokuyama Dental), G-Premio Bond (GC), and Scotchbond Universal (3M ESPE) were used in self-etch mode. The prepared bovine enamel and dentin specimens were divided into two groups based on whether they received an aluminablasting prior to application of the universal adhesives. The resin composite bonded specimens were stored in distilled water at 37°C for 24 hours, following which the shear bond strength (SBS) of half of the specimens was measured (24-hour group). The other half was subjected to 30,000 thermal cycles between 5 and 55°C before SBS measurement (TC group). Surface roughness (Ra) and surface free energy (SFE) of the adherent surfaces were also measured, and scanning electron microscopy observation and scanning electron microscopy/energy-dispersive X-ray analysis were carried out. Most of the adhesives did not show any significant differences in enamel SBS values between the two pretreatment groups, regardless of the storage condition. However, the dentin SBS values were significantly lower in specimens that underwent aluminablasting compared with those that did not, irrespective of their storage conditions. Significantly higher Ra and SFE values were observed in the enamel and dentin of specimens that underwent aluminablasting. Although aluminablasting increased the Ra and SFE values of enamel and dentin, its effect on the SBS value was dependent on the tooth substrate. In addition to C, O, Na, Mg, P, and Ca, the element Al was detected in the enamel and dentin of samples that had undergone aluminablasting. These results suggest that although aluminablasting of the tooth surface is thought to be effective for modification of the adherent surface, it may not enhance enamel bond performance and may also adversely affect the dentin bond effectiveness of the universal adhesives.
Collapse
|
33
|
Ishii R, Takamizawa T, Tsujimoto A, Suzuki S, Imai A, Barkmeier WW, Latta MA, Miyazaki M. Effects of Finishing and Polishing Methods on the Surface Roughness and Surface Free Energy of Bulk-fill Resin Composites. Oper Dent 2019; 45:E91-E104. [PMID: 31738697 DOI: 10.2341/18-246-l] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to determine the influence of finishing and polishing methods on surface properties of bulk-fill resin composites through surface roughness (Ra) and surface free energy (SFE) measurements, and scanning electron microscopy (SEM) observations. Three bulk-fill resin composites, Tetric EvoCeram Bulk Fill (TB), Filtek Bulk Fill (FB), and Filtek Bulk Fill Flowable Restorative (FF), and two conventional resin composites, Clearfil AP-X (AP) and Estelite ∑ Quick (EQ) were used. Seventy cured specimens of each resin composite were prepared and divided into seven groups of 10 specimens. Ra, SFE measurements, and SEM observations were conducted after finishing and polishing procedures. Three groups of specimens were finished with a fine grit diamond bur (FDB), and three with a tungsten carbide bur (CBB). After finishing, one group from each type of finishing was polished with aluminum oxide flexible disks (SSD) and one group from each type of finishing was polished with diamond particles embedded in a silicone point (CMP). A baseline group of samples that were neither finished nor polished after removing the translucent strips from the surface was examined. Although the baseline group showed significantly lower Ra values than the other groups, most resin composites showed lower Ra values with CBB+SSD than with the other finishing and polishing groups. Among the tested resin composites, EQ showed significantly lower Ra values than the other resin composites, regardless of the finishing and polishing methods. On the other hand, AP showed significantly higher Ra values than the other resin composites in all finishing and polishing groups, apart from FB with FDB. For the finished specimens, most resin composites showed higher SFE values with CBB than with FDB. For the polished specimens, all the tested resin composites with CMP showed lower γS values than those with SSD, regardless of the finishing method. The baseline groups of TB and FB showed significantly lower SFE values than the other finished and polished groups. In the SEM observations, all the examined resin composites showed rougher surfaces after finishing with FDB than with CBB. However, when comparing the different polishing methods (CMP and SSD), surface smoothness appeared to be material dependent.
Collapse
|
34
|
Saito T, Takamizawa T, Ishii R, Tsujimoto A, Hirokane E, Barkmeier WW, Latta MA, Miyazaki M. Influence of Application Time on Dentin Bond Performance in Different Etching Modes of Universal Adhesives. Oper Dent 2019; 45:183-195. [PMID: 31567054 DOI: 10.2341/19-028-l] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
We attempted to determine the effect of universal adhesive application time on dentin bond performance in different etching modes based on shear bond strength (SBS) tests and surface free energy (SFE) measurements. The five universal adhesives used were Adhese Universal (AU), Clearfil Universal Bond Quick (CQ), G-Premio Bond (GP), Scotchbond Universal (SU), and Tokuyama Universal Bond (TU). Bovine dentin specimens were divided into four groups of 10 for each adhesive. SBS and SFE were determined after applying the following surface treatments: 1) self-etch (SE) mode with immediate air blowing after adhesive application (IA treatment), 2) SE mode with prolonged application time (PA treatment), 3) etch-and-rinse (ER) mode with IA treatment, and 4) ER mode with PA treatment. Bonded specimens were subjected to SBS testing. The SFE of adhesive-treated dentin surfaces was measured after rinsing with acetone and water. Three-way analysis of variance revealed that dentin SBS values (p<0.001) were significantly influenced by the factors of adhesive type and application duration, but the factor of pre-etching was not significant (p=0.985). The manufacturer's instructions require longer application times for AU and SU, which showed significantly lower SBS values in IA than in PA treatment in both etching modes. However, the difference in the other adhesives was not significant between the IA and PA treatments in either etching mode. The total SFE (γS) was dependent on the adhesive and etching mode. The γS value of the initial group (SiC paper ground group) at baseline was 69.5 (mN·m-1) and that of the pre-etching group at baseline was 30.6 (mN·m-1). For all the adhesives, γS in SE mode showed significantly higher values than in ER mode, regardless of the application time. In SE mode, almost all universal adhesives tested showed lower γS values in PA treatment than in IA treatment. For ER mode, all the adhesives showed significantly higher γS values than those of the pre-etching baseline, regardless of the application time. Most adhesives did not show any significant differences in γS values between IA and PA treatments, regardless of etching mode.
Collapse
|
35
|
Aoki M, Koga K, Miyazaki M, Hamasaki M, Koshikawa N, Oyama M, Kozuka-Hata H, Seiki M, Toole BP, Nabeshima K. CD73 complexes with emmprin to regulate MMP-2 production from co-cultured sarcoma cells and fibroblasts. BMC Cancer 2019; 19:912. [PMID: 31510956 PMCID: PMC6739984 DOI: 10.1186/s12885-019-6127-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Accepted: 09/03/2019] [Indexed: 12/14/2022] Open
Abstract
Background Interaction between cancer cells and fibroblasts mediated by extracellular matrix metalloproteinase inducer (emmprin, CD147) is important in the invasion and proliferation of cancer cells. However, the exact mechanism of emmprin mediated stimulation of matrix metalloprotease-2 (MMP-2) production from fibroblasts has not been elucidated. Our previous studies using an inhibitory peptide against emmprin suggested the presence of a molecule on the cell membrane which forms a complex with emmprin. Here we show that CD73 expressed on fibroblasts interacts with emmprin and is a required factor for MMP-2 production in co-cultures of sarcoma cells with fibroblasts. Methods CD73 along with CD99 was identified by mass spectrometry analysis as an emmprin interacting molecule from a co-culture of cancer cells (epithelioid sarcoma cell line FU-EPS-1) and fibroblasts (immortalized fibroblasts cell line ST353i). MMP-2 production was measured by immunoblot and ELISA. The formation of complexes of CD73 with emmprin was confirmed by immunoprecipitation, and their co-localization in tumor cells and fibroblasts was shown by fluorescent immunostaining and proximity ligation assays. Results Stimulated MMP-2 production in co-culture of cancer cells and fibroblasts was completely suppressed by siRNA knockdown of CD73, but not by CD99 knockdown. MMP-2 production was not suppressed by CD73-specific enzyme inhibitor (APCP). However, MMP-2 production was decreased by CD73 neutralizing antibodies, suggesting that CD73-mediated suppression of MMP-2 production is non-enzymatic. In human epithelioid sarcoma tissues, emmprin was immunohistochemically detected to be mainly expressed in tumor cells, and CD73 was expressed in fibroblasts and tumor cells: emmprin and CD73 were co-localized predominantly on tumor cells. Conclusion This study provides a novel insight into the role of CD73 in emmprin-mediated regulation of MMP-2 production.
Collapse
|
36
|
Rama N, Saha T, Shukla S, Goda C, Milewski D, Mascia A, Vatner R, Sengupta D, Katsis A, Abel E, Girdhani S, Miyazaki M, Rodriguez A, Ku A, Dua R, Parry R, Kalin T. Improved Tumor Control Through T-cell Infiltration Modulated by Ultra-High Dose Rate Proton FLASH Using a Clinical Pencil Beam Scanning Proton System. Int J Radiat Oncol Biol Phys 2019. [DOI: 10.1016/j.ijrobp.2019.06.187] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
37
|
Washio H, Ohira S, Kanayama N, Wada K, Karino T, Komiyama R, Miyazaki M, Teshima T. Effect of a saline flush technique for head and neck imaging in dual-energy CT: improvement of image quality and perivenous artefact reduction using virtual monochromatic imaging. Clin Radiol 2019; 74:805-812. [PMID: 31320111 DOI: 10.1016/j.crad.2019.06.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 06/12/2019] [Indexed: 10/26/2022]
Abstract
AIM To evaluate the effect of the saline flush (SF) technique on the depiction of lesions and the reduction of perivenous artefacts in the head and neck region using dual-energy computed tomography (CT) with virtual monochromatic imaging (VMI). MATERIALS AND METHODS Fifty patients with head and neck cancer were divided into two groups: group A, without a SF and group B, with a 30-ml SF. All images were acquired using fast kilovolt-switching CT (Revolution HD, GE Healthcare, Milwaukee, WI, USA). Contrast-to-noise ratios (CNRs) of the lesions were calculated at VMI energy levels ranging from 40 to 80 keV. Subjective analysis of overall image quality, delineation of lesions, and perivenous artefacts was conducted by two reviewers at both VMI energy level 40 keV and the optimal energy level (which showed optimal CNR by objective analysis). RESULTS Optimal energy level was 63 keV for group A and 61 keV for group B. At VMI energy levels ranging from 40 to 80 keV, the CNR was higher for group B. The highest subjective overall image quality was shown for group B at the optimal energy level (subjective image quality mean value, 3.40). Subjective delineation of lesions was comparable. The perivenous artefact score was significantly higher for group B (2.44 versus 2.74 [p<0.05] at 40 keV, 3.20 versus 3.46 [p<0.05] at the optimal energy level). CONCLUSION The SF technique results in an improvement of lesion CNR and a reduction of perivenous artefacts in VMI using duel-energy CT, especially at 40 keV.
Collapse
|
38
|
Nakano M, Kubo K, Shirota Y, Iwasaki Y, Takahashi Y, Igari T, Inaba Y, Takeshima Y, Tateishi S, Yamashita H, Miyazaki M, Sato H, Kanda H, Kaneko H, Ishii T, Fujio K, Tanaka N, Mimori A. Delayed lupus nephritis in the course of systemic lupus erythematosus is associated with a poorer treatment response: a multicentre, retrospective cohort study in Japan. Lupus 2019; 28:1062-1073. [PMID: 31296139 PMCID: PMC6681441 DOI: 10.1177/0961203319860200] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Objective The objective of this study was to investigate possible differences in
treatment responses between two categories for the onset of lupus
nephritis. Methods We performed a multicentre, retrospective cohort study of class III–V lupus
nephritis patients diagnosed between 1997 and 2014. The renal responses to
initial induction therapy were compared between patients who developed lupus
nephritis within one year from diagnosis of systemic lupus erythematosus
(early (E-) LN) and the remainder (delayed (D-) LN) using the Kaplan–Meier
method. We determined the predictors of renal response as well as renal
flares and long-term renal outcomes using multivariate Cox regression
analyses. Results A total of 107 E-LN and 70 D-LN patients were followed up for a median of
10.2 years. Log-rank tests showed a lower cumulative incidence of complete
response in D-LN compared with E-LN patients. Multivariate analysis
identified D-LN (hazard ratio (HR) 0.48, 95% confidence interval (CI)
0.33–0.70), nephrotic syndrome at baseline, and a chronicity index greater
than 2 as negative predictors of complete response. D-LN patients were more
likely to experience renal flares. D-LN (HR 2.54, 95% CI 1.10–5.83) and
decreased renal function were significant predictors of chronic kidney
disease at baseline. Conclusion D-LN was a predictor of poorer treatment outcomes, in addition to renal
histology and severity of nephritis at lupus nephritis onset.
Collapse
|
39
|
YAMAMOTO T, Miyazaki M, Nakayama M, Sato H, Ito S. SUN-262 CAUSE OF DEATH IN JAPANESE PATIENTS WITH CHRONIC KIDNEY DISEASE: THE GONRYO STUDY. Kidney Int Rep 2019. [DOI: 10.1016/j.ekir.2019.05.667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
40
|
Wong J, Tsujimoto A, Fischer NG, Baruth AG, Barkmeier WW, Johnson EA, Samuel SM, Takamizawa T, Latta MA, Miyazaki M. Enamel Etching for Universal Adhesives: Examination of Enamel Etching Protocols for Optimization of Bonding Effectiveness. Oper Dent 2019; 45:80-91. [PMID: 31226005 DOI: 10.2341/18-275-l] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate whether different enamel etching methods with reduced etching times would improve the bonding effectiveness of universal adhesives. METHODS AND MATERIALS Three enamel etching methods, phosphoric acid ester monomer (PPM) etching, phosphoric acid (PPA) etching, and polyalkenoic acid (PLA) etching, and three universal adhesives, G-Premio Bond (GP), Prime&Bond elect (PE), and Scotchbond Universal Adhesive (SU), were evaluated. Initial bond strengths and fatigue strengths of universal adhesives to ground enamel and ground enamel etched for less than one, five, 10, and 15 seconds using different etching methods were determined. The bonded fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred with a staircase method. Atomic force micrograph (AFM) observations along with measurements of surface Ra roughness and modified surface area of enamel with different etching protocols were also conducted. RESULTS The bond fatigue durability of universal adhesives to enamel with PPA etching from less than one to 15 seconds and PLA etching for 15 seconds was significantly higher than that to ground enamel. The bond fatigue durability to enamel with PPM etching was not increased compared with ground enamel. The surface Ra roughness and surface area obtained with AFM of enamel increased after PPA and PLA etching, and those values were significantly higher than those of ground enamel. Furthermore, surface Ra roughness and surface area with PPA etching were significantly higher than those with PLA etching. However, surface Ra roughness and surface area of enamel with PPM etching were similar to those of ground enamel regardless of etching time. CONCLUSION PPA etching for less than one to 15 seconds and PLA etching for 15 seconds improve universal adhesive bonding, surface Ra roughness, and surface area of enamel. However, PPM etching is not effective, regardless of etching time, in improving bonds strengths, increasing surface roughness, and increasing surface area.
Collapse
|
41
|
Nomura A, Tanigawa T, Muto T, Oga T, Fukushima Y, Kiyosue A, Miyazaki M, Hida E, Satake K. Clinical Efficacy of Telemedicine Compared to Face-to-Face Clinic Visits for Smoking Cessation: Multicenter Open-Label Randomized Controlled Noninferiority Trial. J Med Internet Res 2019; 21:e13520. [PMID: 30982776 PMCID: PMC6660118 DOI: 10.2196/13520] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 03/26/2019] [Accepted: 04/11/2019] [Indexed: 01/30/2023] Open
Abstract
Background Tobacco is a major public health concern. A 12-week standard smoking cessation program is available in Japan; however, it requires face-to-face clinic visits, which has been one of the key obstacles to completing the program, leading to a low smoking cessation success rate. Telemedicine using internet-based video counseling instead of regular clinic visits could address this obstacle. Objective This study aimed to evaluate the efficacy and feasibility of an internet-based remote smoking cessation support program compared with the standard face-to-face clinical visit program among patients with nicotine dependence. Methods This study was a randomized, controlled, open-label, multicenter, noninferiority trial. We recruited nicotine-dependent adults from March to June 2018. Participants randomized to the telemedicine arm received internet-based video counseling, whereas control participants received standard face-to-face clinic visits at each time point in the smoking cessation program. Both arms received a CureApp Smoking Cessation smartphone app with a mobile exhaled carbon monoxide checker. The primary outcome was a continuous abstinence rate (CAR) from weeks 9 to 12. Full analysis set was used for data analysis. Results We randomized 115 participants with nicotine dependence: 58 were allocated to the telemedicine (internet-based video counseling) arm and 57, to the control (standard face-to-face clinical visit) arm. We analyzed all 115 participants for the primary outcome. Both telemedicine and control groups had similar CARs from weeks 9 to 12 (81.0% vs 78.9%; absolute difference, 2.1%; 95% CI –12.8 to 17.0), and the lower limit of the difference between groups (–12.8%) was greater than the prespecified limit (–15%). Conclusions The application of telemedicine using internet-based video counseling as a smoking cessation program had a similar CAR from weeks 9 to 12 as that of the standard face-to-face clinical visit program. The efficacy of the telemedicine-based smoking cessation program was not inferior to that of the standard visit–based smoking cessation program. Trial Registration University Hospital Medical Information Network Clinical Trials Registry: UMIN000031620; https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000035975.
Collapse
|
42
|
Saito H, Fukuhara T, Furuya N, Watanabe K, Sugawara S, Iwasawa S, Tsunezuka Y, Yamaguchi O, Okada M, Yoshimori K, Nakachi I, Gemma A, Azuma K, Kurimoto F, Tsubata Y, Fujita Y, Nagashima H, Asai G, Watanabe S, Miyazaki M, Hagiwara K, Nukiwa T, Morita S, Kobayashi K, Maemondo M. Erlotinib plus bevacizumab versus erlotinib alone in patients with EGFR-positive advanced non-squamous non-small-cell lung cancer (NEJ026): interim analysis of an open-label, randomised, multicentre, phase 3 trial. Lancet Oncol 2019; 20:625-635. [PMID: 30975627 DOI: 10.1016/s1470-2045(19)30035-x] [Citation(s) in RCA: 401] [Impact Index Per Article: 80.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 12/25/2018] [Accepted: 01/04/2019] [Indexed: 01/16/2023]
Abstract
BACKGROUND Resistance to first-generation or second-generation EGFR tyrosine kinase inhibitor (TKI) monotherapy develops in almost half of patients with EGFR-positive non-small-cell lung cancer (NSCLC) after 1 year of treatment. The JO25567 phase 2 trial comparing erlotinib plus bevacizumab combination therapy with erlotinib monotherapy established the activity and manageable toxicity of erlotinib plus bevacizumab in patients with NSCLC. We did a phase 3 trial to validate the results of the JO25567 study and report here the results from the preplanned interim analysis. METHODS In this prespecified interim analysis of the randomised, open-label, phase 3 NEJ026 trial, we recruited patients with stage IIIB-IV disease or recurrent, cytologically or histologically confirmed non-squamous NSCLC with activating EGFR genomic aberrations from 69 centres across Japan. Eligible patients were at least 20 years old, and had an Eastern Cooperative Oncology Group performance status of 2 or lower, no previous chemotherapy for advanced disease, and one or more measurable lesions based on Response Evaluation Criteria in Solid Tumours (1.1). Patients were randomly assigned (1:1) to receive oral erlotinib 150 mg per day plus intravenous bevacizumab 15 mg/kg once every 21 days, or erlotinib 150 mg per day monotherapy. Randomisation was done by minimisation, stratified by sex, smoking status, clinical stage, and EGFR mutation subtype. The primary endpoint was progression-free survival. This study is ongoing; the data cutoff for this prespecified interim analysis was Sept 21, 2017. Efficacy was analysed in the modified intention-to-treat population, which included all randomly assigned patients who received at least one dose of treatment and had at least one response evaluation. Safety was analysed in all patients who received at least one dose of study drug. The trial is registered with the University Hospital Medical Information Network Clinical Trials Registry, number UMIN000017069. FINDINGS Between June 3, 2015, and Aug 31, 2016, 228 patients were randomly assigned to receive erlotinib plus bevacizumab (n=114) or erlotinib alone (n=114). 112 patients in each group were evaluable for efficacy, and safety was evaluated in 112 patients in the combination therapy group and 114 in the monotherapy group. Median follow-up was 12·4 months (IQR 7·0-15·7). At the time of interim analysis, median progression-free survival for patients in the erlotinib plus bevacizumab group was 16·9 months (95% CI 14·2-21·0) compared with 13·3 months (11·1-15·3) for patients in the erlotinib group (hazard ratio 0·605, 95% CI 0·417-0·877; p=0·016). 98 (88%) of 112 patients in the erlotinib plus bevacizumab group and 53 (46%) of 114 patients in the erlotinib alone group had grade 3 or worse adverse events. The most common grade 3-4 adverse event was rash (23 [21%] of 112 patients in the erlotinib plus bevacizumab group vs 24 [21%] of 114 patients in the erlotinib alone group). Nine (8%) of 112 patients in the erlotinib plus bevacizumab group and five (4%) of 114 patients in the erlotinib alone group had serious adverse events. The most common serious adverse events were grade 4 neutropenia (two [2%] of 112 patients in the erlotinib plus bevacizumab group) and grade 4 hepatic dysfunction (one [1%] of 112 patients in the erlotinib plus bevacizumab group and one [1%] of 114 patients in the erlotinib alone group). No treatment-related deaths occurred. INTERPRETATION The results of this interim analysis showed that bevacizumab plus erlotinib combination therapy improves progression-free survival compared with erlotinib alone in patients with EGFR-positive NSCLC. Future studies with longer follow-up, and overall survival and quality-of-life data will be required to further assess the efficacy of this combination in this setting. FUNDING Chugai Pharmaceutical.
Collapse
|
43
|
Inui S, Ueda Y, Ono S, Ohira S, Isono M, Nitta Y, Murata S, Miyazaki M, Teshima T. EP-1747 In vivo dosimetry with electronic portal imaging device in VMAT for prostate cancer. Radiother Oncol 2019. [DOI: 10.1016/s0167-8140(19)32167-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Moritake N, Takamizawa T, Ishii R, Tsujimoto A, Barkmeier WW, Latta MA, Miyazaki M. Effect of Active Application on Bond Durability of Universal Adhesives. Oper Dent 2019; 44:188-199. [DOI: 10.2341/17-384-l] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The purpose of this study was to determine the effect of different adhesive application methods and etching modes on the dentin bond durability of universal adhesives under thermal cycling (TC). All-Bond Universal (Bisco), Adhese Universal (Ivoclar Vivadent), and Scotchbond Universal (3M ESPE) were used as adhesives. In total, 600 bovine teeth with exposed dentin were divided into 12 groups according to the type of adhesive and subjected to the following bonding procedures: 1) etch-and-rinse mode with active application; 2) etch-and-rinse mode with inactive application; 3) self-etch mode with active application; and 4) self-etch mode with inactive application. Bonded specimens were stored in distilled water at 37°C for 24 hours and then subjected to 5000, 10,000, 30,000, or 50,000 TC between 5°C and 55°C before shear bond strength (SBS) testing, creating a division into a total of five different storage conditions. Baseline specimens were stored in distilled water at 37°C for 24 hours. The SBS test was performed at a cross-head speed of 1.0 mm/min. Three-way analysis of variance revealed that all the factors of application mode, adhesive, and thermal cycle period significantly influenced the SBS values (p<0.001), regardless of the etching mode. In the baseline groups, all of the tested adhesives with active application had higher SBS values than those with inactive application, regardless of etching mode. In the TC groups, significantly lower SBS values were observed at 50,000 TC with inactive application compared to those with active application, regardless of the etching mode. From the scanning electron microscopy observation of demineralized and deproteinized resin/dentin interfaces, dense resin tags longer than 50 μm were observed in the etch-and-rinse with active application group. On the other hand, the resin tags in self-etch mode were sparse, thin, and much shorter than those in etch-and-rinse mode. Comparing the penetration status of the resin tags with active and inactive application in self-etch mode, the resin tag penetration with inactive application was much lower than that with active application. Active application is effective in enhancing the dentin bond durability of universal adhesives. When using universal adhesives with different etching modes, practitioners should select the optimal etching mode and appropriate application method in accordance with the cavity conditions.
Collapse
|
45
|
Nagura Y, Tsujimoto A, Fischer NG, Baruth AG, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. Effect of Reduced Universal Adhesive Application Time on Enamel Bond Fatigue and Surface Morphology. Oper Dent 2019; 44:42-53. [DOI: 10.2341/17-261-l] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
The purpose of this study was to evaluate the effect of reduced application times of universal adhesives on enamel bond fatigue and surface morphology of the treated enamel with constant force atomic force microscopy (AFM).
Methods:
Four universal adhesives—Adhese Universal (AU), Clearfil Universal Bond Quick (CU), G-Premio Bond (GP), and Scotchbond Universal Adhesive (SU)—were evaluated in a laboratory for their ability to adhesively bond resin composite to enamel. Shear bond strengths were initially determined using 15 specimens per test group for each adhesive. Shear fatigue strengths were then determined using 20 specimens per test group for each the adhesives. The fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. AFM observations, surface Ra roughness measurements, and geometric surface area evaluations of enamel surface treated with the adhesive agents were also conducted.
Results:
A strong relationship was found between the initial shear bond strength and shear fatigue strength for enamel surface Ra roughness but not for geometric surface area. The initial shear bond strength and shear fatigue strength of CU and GP were not influenced by different application times, unlike those of AU and SU. While the surface area of enamel treated with the adhesive agents was not significantly influenced by different application times and type of adhesive, surface Ra roughness of the enamel in the AU and SU groups significantly increased with increasing application time, unlike CU and GP.
Conclusions:
The results of this study suggest that universal adhesives, used with reduced application times, have adequate Ra surface roughness to provide sufficient resistance to enamel bond fatigue at application times from <1 second to 20 seconds, while the geometric surface area of adhesive-treated enamel did not show any significant changes at these different application times.
Collapse
|
46
|
Ozawa N, Hase T, Hatta T, Sagara A, Ichikawa K, Miyazaki M, Ando M, Yamada K, Hasegawa Y. Retrospective analysis of risk factor of injection site reaction induced by infusion of cisplatin plus vinorelbine. Ann Oncol 2018. [DOI: 10.1093/annonc/mdy442.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
47
|
Hagiwara D, Sato K, Miyazaki M, Kamada M, Moriwaki N, Nakano T, Shiotsuka S, Tokushige C, Toh H, Kamimura H, Togawa A, Takata T. The impact of earlier intervention by an antimicrobial stewardship team for specific antimicrobials in a single weekly intervention. Int J Infect Dis 2018; 77:34-39. [PMID: 30292892 DOI: 10.1016/j.ijid.2018.09.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 09/26/2018] [Accepted: 09/28/2018] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVE The objective of this study was to evaluate the effects of earlier intervention by an antimicrobial stewardship team (AST) on antimicrobial use, antimicrobial resistance rates, and the clinical outcomes, without changing the weekly intervention schedule. METHODS A retrospective study was conducted at Fukuoka University Hospital between April 2013 and March 2016. The effects were compared among three study periods (SP): SP1 (patients receiving anti-methicillin-resistant Staphylococcus aureus agents and carbapenems for ≥14 days), SP2 (patients receiving specific antimicrobials for ≥14 days), and SP3 (patients receiving specific antimicrobials regardless of the duration of treatment). RESULTS The timing of AST intervention was shortened from an average of 15.5days after administration in SP1 to 4.2 days in SP3. The antimicrobial use density (AUD) of carbapenems and piperacillin-tazobactam decreased significantly (SP2 vs. SP3, p<0.05), and the costs of specific antimicrobials decreased (SP1, US$ 1080000; SP2, US$ 944000; SP3, US$ 763000). The rates of carbapenem resistance among Pseudomonas aeruginosa isolates showed a significant reduction from 16.2% in SP2 to 8.7% in SP3 (p<0.05). The mortality rate and length of stay did not change during the study period. CONCLUSIONS Earlier intervention by an AST could contribute to the proper use of antimicrobials without adversely affecting patient outcomes.
Collapse
|
48
|
Aguzzi J, Fanelli E, Ciuffardi T, Schirone A, De Leo FC, Doya C, Kawato M, Miyazaki M, Furushima Y, Costa C, Fujiwara Y. Faunal activity rhythms influencing early community succession of an implanted whale carcass offshore Sagami Bay, Japan. Sci Rep 2018; 8:11163. [PMID: 30042515 PMCID: PMC6057991 DOI: 10.1038/s41598-018-29431-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 07/03/2018] [Indexed: 11/20/2022] Open
Abstract
Benthic community succession patterns at whale falls have been previously established by means of punctual submersible and ROV observations. The contribution of faunal activity rhythms in response to internal tides and photoperiod cues to that community succession dynamism has never been evaluated. Here, we present results from a high-frequency monitoring experiment of an implanted sperm whale carcass in the continental slope (500 m depth) offshore Sagami Bay, Japan. The benthic community succession was monitored at a high frequency in a prolonged fashion (i.e. 2-h intervals for 2.5 months) with a seafloor lander equipped with a time-lapse video camera and an acoustic Doppler profiler to concomitantly study current flow dynamics. We reported here for the first time, to the best of our knowledge, the occurrence of strong 24-h day-night driven behavioral rhythms of the most abundant species (Simenchelys parasitica; Macrocheira kaempferi, and Pterothrissus gissu). Those rhythms were detected in detriment of tidally-controlled ones. Evidence of a diel temporal niche portioning between scavengers and predators avoiding co-occurrence at the carcass, is also provided. The high-frequency photographic and oceanographic data acquisition also helped to precisely discriminate the transition timing between the successional stages previously described for whale falls’ attendant communities.
Collapse
|
49
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. Influence of Thermal Stress on Simulated Localized and Generalized Wear of Nanofilled Resin Composites. Oper Dent 2018; 43:380-390. [DOI: 10.2341/16-206-l] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
This study investigated the influence of thermal stress on the simulated localized and generalized wear of nanofilled resin composites.
Methods:
Six nanofilled resin composites were evaluated and then subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulation device after 24 hours of water storage (24-hour group) and 24 hours of water storage and 10,000 thermal cycles (TC group). Simulated localized wear was generated using a stainless-steel ball bearing, and simulated generalized wear was generated using a flat-ended stainless-steel cylinder. Wear testing was accomplished in a water slurry of polymethyl methacrylate beads. Simulated localized and generalized wear was determined using a noncontact profilometer (Proscan 2100) in conjunction with Proscan and AnSur 3D software.
Results:
Wear was significantly different (p<0.05) among the resin composites for both simulated localized and generalized wear of either the 24-hour group or the TC group. The simulated localized wear of the TC group was significantly greater than that of the 24-hour group; however, the simulated generalized wear of most of the resin composites of the TC group was not significantly different from that of the 24-hour group.
Conclusion:
The simulated localized and generalized wear of nanofilled resin composites is material dependent. The simulated localized wear of nanofilled resin composites appears to be influenced by thermal stress, whereas this effect is not as apparent in simulated generalized wear testing.
Collapse
|
50
|
Miyazaki M, Asai Y, Iwakura M, Hara M. 0442 Safety and Efficacy of Suvorexant in a Real World Setting: Results from the Drug Use-results Survey in Japan. Sleep 2018. [DOI: 10.1093/sleep/zsy061.441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|