26
|
Maines M, Tomasi G, Moggio P, Peruzza F, Catanzariti D, Angheben C, Simoncelli M, Degiampietro M, Piffer L, Valsecchi S, Del Greco M. Implementation of remote follow-up of cardiac implantable electronic devices in clinical practice: organizational implications and resource consumption. J Cardiovasc Med (Hagerstown) 2020; 21:648-653. [DOI: 10.2459/jcm.0000000000001011] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
27
|
Zanotto G, Melissano D, Baccillieri S, Campana A, Caravati F, Maines M, Platania F, Zuccaro L, Landolina M, Berisso MZ, Boriani G, Ricci RP. Intrahospital organizational model of remote monitoring data sharing, for a global management of patients with cardiac implantable electronic devices. J Cardiovasc Med (Hagerstown) 2020; 21:171-181. [DOI: 10.2459/jcm.0000000000000912] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
28
|
Morani G, Facchin D, Molon G, Zanotto G, Maines M, Zoppo F, Themistoclakis S, Allocca G, Dametto E, Bertaglia E, Turrini P, Bolzan B, Costa A, Proclemer A, Ribichini FL. Prediction of mortality in patients with implantable defibrillator using CHADS2 score: data from a prospective observational investigation. AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE 2018; 8:48-57. [PMID: 30697450 PMCID: PMC6334196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Accepted: 11/29/2018] [Indexed: 06/09/2023]
Abstract
BACKGROUND CHADS2 (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, previous stroke/TIA) score has been validated as a risk stratification score to predict stroke in patients with atrial fibrillation (AF). The objective of this analysis was to assess whether patient risk factors, in particular CHADS2 score, identified patients at risk of mortality. METHODS 821 patients with an implantable cardioverter defibrillator were prospectively followed-up in 11 cardiology centers. Patients were grouped in 3 groups according to pre-specified risk classes: low (CHADS2 = 0), moderate (CHADS2 = 1, 2), and high (CHADS2 = 3-6). Information on clinical status and events, were collected during scheduled and unscheduled follow-up visits. Deaths were retrieved from medical records, or through the Regional Office of Vital Statistics. RESULTS Over a mean follow-up of 44±26 months, 135 deaths occurred in the overall population: 6 (7.7%) in the low-risk population, 69 (13.8%) in moderate-risk patients and 60 (24.6%) in high-risk patients. Kaplan-Meier estimated of patient survival were significantly different in 3 patients groups (93.0%, 90.1%, 78.5% in low, moderate and high risk patients respectively, at 4 years P<0.001). A sub-analysis on patients without history of AF showed similar results. Multivariate regression analysis adjusted for baseline characteristics confirmed the high risk status (HR 1.88, 95% CI 1.27-2.80; P = 0.002) as an independent predictor of mortality adjusted for the baseline characteristics. CONCLUSIONS In our multicenter research, the long-term mortality was higher in patients with high CHADS2 score than in those with lower risk score regardless the presence of history of AF. CHADS2 score could be considered a toll to predict all causes mortality.
Collapse
|
29
|
Peruzza F, Maines M, Catanzariti D, Tomasi G, Angheben C, Del Greco M. [A misleading prolonged asystole: a case of implantable loop recorder dehiscence]. GIORNALE ITALIANO DI CARDIOLOGIA (2006) 2018; 19:246-247. [PMID: 29912240 DOI: 10.1714/2898.29220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
|
30
|
Zucchelli G, Sirico G, Rebellato L, Marini M, Stabile G, Del Greco M, Castro A, De Ruvo E, Soldati E, Zingarini G, Ocello S, Daleffe E, Mantica M, Pandozi C, Maines M, Guarracini F, Bongiorni MG. Contiguity Between Ablation Lesions and Strict Catheter Stability Settings Assessed by VISITAG TM Module Improve Clinical Outcomes of Paroxysmal Atrial Fibrillation Ablation ― Results From the VISITALY Study ―. Circ J 2018; 82:974-982. [DOI: 10.1253/circj.cj-17-0421] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
31
|
Pastore G, Morani G, Maines M, Marcantoni L, Bolzan B, Zanon F, Noventa F, Corbucci G, Baracca E, Picariello C, Lanza D, Zuin M, Roncon L, Barold SS. Patients with right bundle branch block and concomitant delayed left ventricular activation respond to cardiac resynchronization therapy. Europace 2017; 20:e171-e178. [DOI: 10.1093/europace/eux362] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 11/29/2017] [Indexed: 11/12/2022] Open
|
32
|
Maines M, Zorzi A, Tomasi G, Angheben C, Catanzariti D, Piffer L, Del Greco M. Clinical impact, safety, and accuracy of the remotely monitored implantable loop recorder Medtronic Reveal LINQTM. Europace 2017; 20:1050-1057. [DOI: 10.1093/europace/eux187] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Accepted: 05/26/2017] [Indexed: 11/14/2022] Open
|
33
|
Pastore G, Marcantoni L, Zanon F, Maines M, Corbucci G, Noventa F, Piccariello C, Baracca E, Carraro M, Conte L, Roncon L. P1006Patients with RBBB and concomitant delayed LV activation respond to CRT. Europace 2017. [DOI: 10.1093/ehjci/eux151.187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
34
|
Del Greco M, Zorzi A, Di Matteo I, Cima A, Maines M, Angheben C, Catanzariti D. Coronary sinus activation patterns in patients with and without left bundle branch block undergoing electroanatomic mapping system-guided cardiac resynchronization therapy device implantation. Heart Rhythm 2016; 14:225-233. [PMID: 27989791 DOI: 10.1016/j.hrthm.2016.10.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Indexed: 11/17/2022]
Abstract
BACKGROUND Implantation of the left ventricular (LV) lead in segments with delayed electrical activation may improve response to cardiac resynchronization therapy (CRT). OBJECTIVE The purpose of this study was to evaluate the amount and regional distribution of LV electrical delay (LVED) in patients with or without left bundle branch block (LBBB). METHODS We enrolled 60 patients who underwent electroanatomic mapping system-guided CRT device implantation. Activation mapping of the coronary sinus (CS) branches was performed using an insulated guidewire. LVED was defined as the interval between the beginning of the QRS complex on the surface electrocardiogram (ECG) and the local electrogram and expressed in milliseconds or as percentage of the total QRS duration (LVED%). RESULTS Forty-three patients showed a LBBB and 17 a non-LBBB electrocardiographic pattern. A total of 148 CS branches (mean 2.5 per patient; range 2-4 per patient) were mapped. Patients with LBBB showed higher maximum LVED (135 ms [108-150 ms] vs 100 ms [103-110 ms]; P < .001) and LVED% (86% [79%-89%] vs 72% [54%-80%]; P < .001) than did patients without LBBB. The maximum LVED was recorded in mid-basal anterolateral or inferolateral LV segments (traditional CRT targets), significantly more often in patients with LBBB than in patients without LBBB (85% vs 59%; P = .02). The number of CS branches showing LVED >50% of the total QRS duration, >75% of the total QRS duration, and >85 ms was significantly higher in patients with LBBB than in patients without LBBB. CONCLUSION Patients without LBBB showed lower LVED and more heterogeneous electrical activation of the CS than did patients with LBBB. This finding may contribute to a lower rate of response to CRT of patients without LBBB and suggests the use of activation mapping to guide LV lead placement.
Collapse
|
35
|
Pastore G, Maines M, Marcantoni L, Zanon F, Noventa F, Corbucci G, Baracca E, Aggio S, Picariello C, Lanza D, Rigatelli G, Carraro M, Roncon L, Barold SS. ECG parameters predict left ventricular conduction delay in patients with left ventricular dysfunction. Heart Rhythm 2016; 13:2289-2296. [DOI: 10.1016/j.hrthm.2016.07.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Indexed: 11/27/2022]
|
36
|
Greco MD, Cima A, Carlo A, Maines M, Catanzariti D, Viliani D, Indiani S, Pertile R. 136-60: Can the QRS morphology predict the latest activated site during CRT implantation using an electroanatomic mapping of the coronary venous? Europace 2016. [DOI: 10.1093/europace/18.suppl_1.i105b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
37
|
Greco MD, Cima A, Carlo A, Maines M, Catanzariti D, Viliani D, Indiani S, Pertile R. 96-68: The QRS morphology influences the amount of LV activation delay mapped during coronary venous electroanatomic mapping in CRT implantation. Europace 2016. [DOI: 10.1093/europace/18.suppl_1.i78a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
38
|
Pastore G, Marcantoni L, Maines M, Zanon F, Carraro M, Baracca E, Picariello C, Lanza D, Conte L, Roncon L. 136-59: Relation between ECG parameters and LV electrical delay in patients with left ventricular dysfunction. Europace 2016. [DOI: 10.1093/europace/18.suppl_1.i105a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
39
|
Curnis A, Tondo C, Ardito C, Padeletti L, Verlato R, Porcellini S, Leoni L, Maines M, Amellone C, Rauhe W, Sciarra L, Arena G. 176-20: Cryoballoon ablation as treatment of recent paroxysmal atrial fibrillation. Data from a large cohort of patients followed in a real world multicenter experience. Europace 2016. [DOI: 10.1093/europace/18.suppl_1.i122a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
40
|
Palamara S, Vergara C, Catanzariti D, Faggiano E, Pangrazzi C, Centonze M, Nobile F, Maines M, Quarteroni A. Computational generation of the Purkinje network driven by clinical measurements: the case of pathological propagations. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2014; 30:1558-77. [PMID: 25319252 DOI: 10.1002/cnm.2689] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 09/25/2014] [Accepted: 09/25/2014] [Indexed: 05/16/2023]
Abstract
To properly describe the electrical activity of the left ventricle, it is necessary to model the Purkinje fibers, responsible for the fast and coordinate ventricular activation, and their interaction with the muscular propagation. The aim of this work is to propose a methodology for the generation of a patient-specific Purkinje network driven by clinical measurements of the activation times related to pathological propagations. In this case, one needs to consider a strongly coupled problem between the network and the muscle, where the feedback from the latter to the former cannot be neglected as in a normal propagation. We apply the proposed strategy to data acquired on three subjects, one of them suffering from muscular conduction problems owing to a scar and the other two with a muscular pre-excitation syndrome (Wolff-Parkinson-White). To assess the accuracy of the proposed method, we compare the results obtained by using the patient-specific Purkinje network generated by our strategy with the ones obtained by using a non-patient-specific network. The results show that the mean absolute errors in the activation time is reduced for all the cases, highlighting the importance of including a patient-specific Purkinje network in computational models.
Collapse
|
41
|
Vergara C, Palamara S, Catanzariti D, Nobile F, Faggiano E, Pangrazzi C, Centonze M, Maines M, Quarteroni A, Vergara G. Patient-specific generation of the Purkinje network driven by clinical measurements of a normal propagation. Med Biol Eng Comput 2014. [PMID: 25151397 DOI: 10.1007/sll517-014-1183-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The propagation of the electrical signal in the Purkinje network is the starting point for the activation of the ventricular muscular cells leading to the contraction of the ventricle. In the computational models, describing the electrical activity of the ventricle is therefore important to account for the Purkinje fibers. Until now, the inclusion of such fibers has been obtained either by using surrogates such as space-dependent conduction properties or by generating a network based on an a priori anatomical knowledge. The aim of this work was to propose a new method for the generation of the Purkinje network using clinical measures of the activation times on the endocardium related to a normal electrical propagation, allowing to generate a patient-specific network. The measures were acquired by means of the EnSite NavX system. This system allows to measure for each point of the ventricular endocardium the time at which the activation front, that spreads through the ventricle, has reached the subjacent muscle. We compared the accuracy of the proposed method with the one of other strategies proposed so far in the literature for three subjects with a normal electrical propagation. The results showed that with our method we were able to reduce the absolute errors, intended as the difference between the measured and the computed data, by a factor in the range 9-25 %, with respect to the best of the other strategies. This highlighted the reliability of the proposed method and the importance of including a patient-specific Purkinje network in computational models.
Collapse
|
42
|
Catanzariti D, Maines M, Angheben C. [How to identify non-responders to cardiac resynchronization therapy]. GIORNALE ITALIANO DI CARDIOLOGIA (2006) 2012; 13:152S-156S. [PMID: 23096395 DOI: 10.1714/1167.12940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Cardiac resynchronization therapy (CRT) has been shown to improve survival, morbidity, symptoms, quality of life and exercise capacity, and to promote a beneficial reverse remodeling of the left ventricle in patients with heart failure, dilated hypokinetic left ventricle and wide QRS. The totality of evidence supports the use of CRT also in patients with mild symptoms (NYHA class II). However, the wider diffusion of CRT is determining a growing clinical and economic impact on national health systems. In clinical practice, in spite of "all-or-none" response, variable degrees of therapy response are commonly observed, but several evidence gaps remain to be addressed. According to recent guidelines for CRT implantation, a multiparametric combination of predictive factors emerging from the analysis of clinical trials, observational studies and registries, represents a useful tool for patient selection.
Collapse
|
43
|
Catanzariti D, Maines M, Manica A, Angheben C, Varbaro A, Vergara G. Permanent His-bundle pacing maintains long-term ventricular synchrony and left ventricular performance, unlike conventional right ventricular apical pacing. Europace 2012; 15:546-53. [PMID: 22997222 DOI: 10.1093/europace/eus313] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Right ventricular apical pacing (RVAP) may be deleterious, determining abnormal left ventricular (LV) electrical activation and progressive LV dysfunction. Permanent His-bundle pacing (HBP) has been proposed to prevent this detrimental effect. The aim of our study was to compare the long-term effects of HBP on LV synchrony and systolic performance with those of RVAP in the same group of patients. METHODS Our analysis included 26 patients who received both an HBP lead and an RVAP lead, as backup, in our electrophysiology laboratory between 2004 and 2007. After implantation, all devices were programmed to obtain HBP. An intra-patient comparison of the effects of HBP and RVAP on LV dyssynchrony and function was performed at the last available follow-up examination. RESULTS After a mean of 34.6 ± 11 months, the pacing modality was temporarily switched to RVAP. During RVAP, LV ejection fraction significantly decreased (50.1 ± 8.8% vs. 57.3 ± 8.5%, P < 0.001), mitral regurgitation significantly increased (22.5 ± 10.9% vs.16.3 ± 12.4%; P = 0.018), and inter-ventricular delay significantly worsened (33.4 ± 19.5 ms vs. 7.1 ± 4.7 ms, P = 0.003) in comparison with HBP. However, the myocardial performance index was not statistically different between the two pacing modalities (P = 0.779). No asynchrony was revealed by tissue Doppler imaging during HBP, while during RVAP the asynchrony index was significantly higher in both the four-chamber (125.8 ± 63.9 ms; P = 0.035 vs. HBP) and two-chamber (126 ± 86.5 ms; P = 0.037 vs. HBP) apical views. CONCLUSION His-bundle pacing has long-term positive effects on inter- and intra-ventricular synchrony and ventricular contractile performance in comparison with RVAP. It prevents asynchronous pacing-induced LV ejection fraction depression and mitral regurgitation.
Collapse
|
44
|
Tomasi L, Zanotto G, Zanolla L, Golia G, Ometto R, Bonanno C, Vergara G, Maines M, Lonardi G, Visentin E, Rauhe W, Latina L, Perrone C, Varbaro A, DE Santo T. Physiopathologic correlates of intrathoracic impedance in chronic heart failure patients. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2010; 34:407-13. [PMID: 21091745 DOI: 10.1111/j.1540-8159.2010.02979.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Increased plasma levels of amino-terminal fraction of brain natriuretic peptide (NT-proBNP) and alterations of diastolic filling as described by Doppler transmitral flow pattern are well-known markers of decompensated heart failure (HF). Recently, some implantable defibrillators have allowed monitoring of intrathoracic impedance, which is related to lung water content, potentially indicating HF deterioration. The aim of this study was to assess the correlation between intrathoracic impedance and NT-proBNP and echo-Doppler transmitral flow indexes. METHODS Data were collected from 111 HF patients, in six Italian centers. All patients were on optimal medical therapy. Device diagnostics, echographic data, NT-proBNP determination, and clinical status as assessed by the Heart Failure Score (HFS) were registered at baseline, at bimonthly visits, and at unscheduled examinations due to HF decompensation or device alerts. RESULTS Over a median follow-up of 413 days, 955 examinations were performed. Intrathoracic impedance was significantly correlated with NT-proBNP (P = 0.013) and with mitral E-wave deceleration time (DtE) (P = 0.017), but not with HFS. At the time of confirmed alert events, NT-proBNP was significantly higher than during confirmed nonalert event examinations; DtE did not differ, whereas impedance was significantly lower. CONCLUSION A decrease in intrathoracic impedance is inversely correlated with NT-proBNP and directly correlated with DtE. Intrathoracic impedance monitoring therefore has the physiologic basis for being a useful tool to identify early HF decompensation.
Collapse
|
45
|
Maines M, Catanzariti D, Cirrincione C, Valsecchi S, Comisso J, Vergara G. Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration. Europace 2010; 12:680-5. [DOI: 10.1093/europace/eup419] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
46
|
Maines M, Landolina M, Lunati M, Lonardi G, Pappone A, Proclemer A, Zanotto G, Santini M, Varbaro A, Vimercati M, Valsecchi S. Intrathoracic and ventricular impedances are associated with changes in ventricular volume in patients receiving defibrillators for CRT. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2009; 33:64-73. [PMID: 19821939 DOI: 10.1111/j.1540-8159.2009.02579.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Some implantable cardioverter defibrillators (ICD) are able to monitor intrathoracic impedance to detect pulmonary fluid overload. This is achieved by measuring impedance between the ICD case and the right ventricular (RV) lead. We hypothesized that the measured impedance would rise with improvement in left ventricular (LV) volumes during cardiac resynchronization therapy (CRT), and that such impedance changes would be more apparent when measured with an alternative pacing vector. METHODS We analyzed echocardiographic and impedance data from heart failure patients implanted with a CRT-ICD capable of intrathoracic impedance measurement for fluid accumulation diagnosis, and LV pacing impedance recording for lead integrity monitoring. RESULTS In 127 out of 170 patients that received de novo CRT implantation, the LV end-systolic volume (LVESV) decreased at 6-month follow-up (LVESV at 6 month-LVESV at baseline <0: group A). For the remaining 43 patients (group B) the change was > or = 0. Despite comparable values at baseline (P = 0.262), the impedances of groups A and B gradually diverged soon after the implant, resulting in significant difference between the two groups at the 6-month visit (P = 0.001). The changes in LV dimensions produced larger differences between groups in the impedance measured between the LV and the RV leads (P < 0.001). The regression analysis demonstrated an inverse correlation between paired changes of volume and intrathoracic impedance. Higher correlation coefficient was obtained using the LV-to-RV measurement vector (r =-0.635, P < 0.001). CONCLUSIONS The changes in ICD-measured impedance seem associated with the LV volume changes induced by CRT. Specifically, the LV-to-RV impedance estimations seem to better correlate with paired changes of ventricular volumes.
Collapse
|
47
|
Arbelo Lainez E, Garcia Quintana A, Caballero Dorta E, Diaz Escofet M, Moreno Djadou B, Rios Diaz C, Novoa Medina J, Medina Fernandez-Aceytuno A, Fatemi M, Le Gal G, Castellant P, Fersi I, Etienne Y, Blanc JJ, Zanon F, Aggio S, Baracca E, Pastore F, Vaccari D, Verlato R, Davinelli M, Comisso J, Barsheshet A, Abu Sham'a R, Sandach A, Luria D, Bar Lev D, Gurevitz O, Eldar M, Glikson M, Ramos R, Oliveira M, Nogueira Da Silva M, Toste A, Lousinha A, Branco L, Alves S, Ferreira RC, Baptista R, Saraiva F, Jorge E, Hermida P, Monteiro P, Elvas L, Providencia LA, Delnoy PPHM, Ottervanger JP, Oude Luttikhuis H, Elvan A, Ramdat Misier AR, Beukema WP, Van Hemel NM, Lunati M, Maines M, Landolina M, Santini M, Proclemer A, Sassara M, Marchesini S, Varbaro A, Maines M, Catanzariti D, Cemin C, Vimercati M, Valsecchi S, Vergara G, Bertini M, Ajmone Marsan N, Delgado V, Van Bommel RJ, Nucifora G, Borleffs CJW, Schalij MJ, Bax JJ. Moderated posters: Cardiac resynchronisation therapy. Europace 2009. [DOI: 10.1093/europace/euq242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
48
|
Maines M, Catanzariti D, Cemin C, Vaccarini C, Vergara G. Usefulness of intrathoracic fluids accumulation monitoring with an implantable biventricular defibrillator in reducing hospitalizations in patients with heart failure: A case-control study. J Interv Card Electrophysiol 2007; 19:201-7. [PMID: 17805952 DOI: 10.1007/s10840-007-9155-4] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2007] [Accepted: 07/24/2007] [Indexed: 01/28/2023]
Abstract
BACKGROUND The reduction of hospitalizations in patients with heart failure (HF) may have clinical and economical implications. MATERIALS AND METHODS In a case-control study, we compared the number of hospital admissions for congestive HF during the same follow-up period in two homogeneous groups of patients, each consisting of 27 consecutive patients treated with biventricular pacing and back-up defibrillator (B-ICD) in our institution. The first group was implanted with an InSync Sentry, (Medtronic Inc, Minneapolis, MN, US), a B-ICD device with the OptiVol feature for monitoring intrathoracic fluid accumulation and equipped with an active acoustic alarm (Group 1); the second group was implanted with an InSync III Marquis (Medtronic), a B-ICD device with similar features except for the absence of the OptiVol (Group 2). Follow-up visits were performed at 3 month interval or in case of acoustic alarm. RESULTS The patient clinical characteristics of the two groups were similar. In Group 1, with 359 +/- 98 days follow-up, 12 of the 27 patients, experienced 18 OptiVol alarms with only one hospital admission for congestive HF occurring in a patient who ignored the acoustic alarm for 13 days. In Group 2, eight HF hospitalizations occurred in seven patients (p < 0.05). CONCLUSIONS The OptiVol feature is a useful tool for the clinical management of HF patients as it can result in early treatment during the pre-clinic stage of HF decompensation and in a significant reduction of hospital admissions for congestive HF.
Collapse
|
49
|
Catanzariti D, Maines M, Cemin C, Broso G, Marotta T, Vergara G. Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing. An intrapatient acute comparison study. J Interv Card Electrophysiol 2006; 16:81-92. [PMID: 17115267 DOI: 10.1007/s10840-006-9033-5] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2006] [Accepted: 07/10/2006] [Indexed: 02/03/2023]
Abstract
BACKGROUND Benefits of A-V synchrony during right ventricular apical pacing are neutralized by induction of ventricular dyssynchrony. Only a few data are reported about direct His bundle pacing influence on ventricular synchronism. AIM Was to assess the capability of direct His bundle pacing to prevent pacing-induced ventricular dyssynchrony comparing DDD- (or VVI- in case of Atrial Fibrillation) right ventricular apical pacing with DDD- (or VVI-) direct His bundle pacing in the same patients cohort. METHODS 23 of 24 patients (mean age 75.1 +/- 6.4 years) with narrow QRS (HV < 65 ms) underwent permanent direct His bundle pacing for "brady-tachy syndrome" (11) or supra-Hisian II/III-degree AV Block (permanent atrial fibrillation 7, AV Node ablation 1). A 4.1 F screw-in lead was fixed in His position, guided by endocardial pacemapping and unipolar recordings. Additional permanent (13 patients) or temporary right ventricular apical pacing leads were also positioned. Inter- and left intra-ventricular dyssynchrony, mitral regurgitation and left systolic ventricular function Tei index were assessed during either direct His bundle pacing or right ventricular apical pacing. RESULTS Permanent direct His bundle pacing was obtained in 23 of 24 patients. Indexes of ventricular dyssynchrony were drastically reduced, mitral regurgitation decreased and left systolic ventricular function Tei index improved during direct His bundle pacing (or His bundle and septum pacing) in comparison to apical pacing (p < 0.05). No statistically significant differences were observed between direct His bundle pacing and combined His bundle and septum pacing. CONCLUSION Direct His bundle pacing (also fused with adjacent septum capture) prevents pacing-induced ventricular dyssynchrony.
Collapse
|
50
|
Maines M, Catanzariti D, Cemin C, Musuraca G, Vaccarini C, Vergara G. AB48-4. Heart Rhythm 2006. [DOI: 10.1016/j.hrthm.2006.02.303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|