26
|
Wexberg P, Mück K, Windberger U, Lang S, Osranek M, Weidinger F, Maurer G, Gottsauner-Wolf M. Adventitial response to intravascular brachytherapy in a rabbit model of restenosis. Wien Klin Wochenschr 2004; 116:190-5. [PMID: 15088994 DOI: 10.1007/bf03040486] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND The incidence of late major adverse cardiac events (MACE) after coronary brachytherapy is higher than in controls. Because expansive remodeling has been shown to correlate with poor clinical outcome after vascular interventions, we studied adventitial changes after intravascular irradiation in a rabbit model. METHODS Twenty normolipidemic rabbits underwent balloon injury in both external iliac arteries. One artery was assigned for subsequent irradiation with a 90Y source (15 Gy or 30 Gy at 0.5 mm in the vessel wall). After four weeks morphometric measurements were made and cell density and collagen amount determined. Staining for Ki67 identified proliferating cells; apoptotic cells were identified by TUNEL staining. Proliferative and apoptotic indices were calculated as the number of respective positive cells/total cell count x100. RESULTS The neointimal area decreased to 0.27 +/- 0.3 mm2 after irradiation compared with 0.55 +/- 0.2 mm2 in controls (p=0.007), whereas adventitial area increased from 0.62 +/- 0.3 mm2 to 0.87 +/- 0.3 mm2 (p=0.02). Irradiation reduced both the proliferative (0.95 +/- 2.6 vs. 3.73 +/- 4.7, p=0.026) and apoptotic (0.006 +/- 0.02 vs. 0.107 +/- 0.2, p=0.03) indices in the neointima, but not in the other arterial-wall layers. Collagen amount and arterial remodeling did not differ between the groups. There was no difference between 15 and 30 Gy in any of the parameters, although adventitial thickening was more pronounced in the high-dose group. CONCLUSIONS In normolipidemic rabbits, intravascular beta-irradiation after balloon angioplasty is associated with an increase in neoadventitia and a reduction of neointima. It is conceivable that this phenomenon may contribute to the increased incidence of late MACE after vascular brachytherapy.
Collapse
|
27
|
Gyöngyösi M, Sperker W, Csonka C, Bonderman D, Lang I, Strehblow C, Adlbrecht C, Shirazi M, Windberger U, Marlovits S, Gottsauner-Wolf M, Wexberg P, Kockx M, Ferdinandy P, Glogar D. Inhibition of interleukin-1beta convertase is associated with decrease of neointimal hyperplasia after coronary artery stenting in pigs. Mol Cell Biochem 2003; 249:39-43. [PMID: 12956396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
Inhibition of IL-1beta convertase has been shown to decrease inflammation and apoptosis, which are features of the neointimal development after vascular interventions. The aim of our study was to reduce neointimal proliferation after stenting of the porcine coronary artery, using the irreversible IL-1beta convertase and caspase-1 inhibitor acetyl-tyrosinyl-valyl-alanyl-aspartyl-chloromethyl-ketone (Ac-YVAD-cmk). Before coronary stent implantation, 8 pigs received an intracoronary infusion of 50 mg Ac-YVAD-cmk into the left coronary artery (group 1, n = 8), while 8 animals served as untreated controls (group 2). After 4 weeks, coronary angiography and intracoronary ultrasound (IVUS) with 3D measurements were performed. IVUS revealed a smaller in-stent intimal volume (27.3 +/- 11.6 vs. 75.8 +/- 18.4 mm3, p < 0.005) and a decreased maximal percentage area stenosis (36.1 +/- 8.5 vs. 69.0 +/- 8.2%, p < 0.001) in group 1 vs. group 2. A smaller maximal neointimal thickness (0.63 +/- 0.28 vs. 1.75 +/- 0.94 mm, p < 0.005) and a decreased maximal neointimal area (2.14 +/- 1.29 vs. 5.03 +/- 1.92 mm2, p < 0.005), assessed by computerized planimetry, were found in group 1 vs. group 2. Lower apoptotic indices of the neointimal cells were observed in the treated animals (3.0 vs. 13.4% of total intimal cells, p < 0.05). The coronary arterial tissue IL-1beta level was significantly decreased in the animals treated with Ac-YVAD-cmk (0.254 +/- 0.162 vs. 0.463 +/- 0.307 pg/mg protein, p < 0.05), and exhibited a positive linear correlation (r = 0.581, p = 0.013) with the in-stent plaque volume. In conclusion, intracoronary administration of Ac-YVAD-cmk before coronary artery stenting results in significantly decreased neointimal hyperplasia due to the inhibition of local IL-1beta production and decreased neointimal apoptosis.
Collapse
|
28
|
Syeda B, Gottsauner-Wolf M, Denk S, Pichler P, Khorsand A, Glogar D. Arterial compliance: a diagnostic marker for atherosclerotic plaque burden? Am J Hypertens 2003; 16:356-62. [PMID: 12745196 DOI: 10.1016/s0895-7061(03)00037-2] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
BACKGROUND Previous studies have shown atherogenesis to be related with increased vessel stiffness. Measures of the arterial compliance can be performed noninvasively from pressure pulse contour analysis of arterial waveforms. In this prospective study we aimed to analyze to what extent vessel compliance can reflect the angiographic coronary artery status. METHODS Large and small arterial elasticity indices (LAEI in milliliters per mm Hg x 10 and SAEI in milliliters per mm Hg x 100) were measured in 151 patients on the radial artery with the PulseWave Sensor HDI device. All patients were classified into diffuse-coronary artery disease (CAD) (defined as stenosis length >15 mm), focal-CAD (defined as stenosis length between 1 and 15 mm), or no-CAD. RESULTS We found both LAEI and SAEI to be reduced in the diabetic group (LAEI: 11.2 +/- 2.9 v 13.4 +/- 4.5, P =.006; SAEI: 3.7 +/- 1.6 v 4.7 +/- 2.4, P =.01). Inverse association was seen between age and LAEI (r = -0.41; P <.001) and SAEI (r = -0.38; P <.001). No-CAD was found in 31 patients, focal-CAD in 64 patients, and diffuse-CAD in 56 patients. Mean LAEI were 13.8 +/- 3.5, 13.7 +/- 4.7, and 11.3 +/- 3.5 in the groups no-CAD, focal-CAD, and diffuse-CAD, respectively (P =.004), (no-CAD versus diffuse-CAD: P =.04; focal-CAD versus diffuse-CAD: P =.009). Respective SAEI values were 5.6 +/- 2.5, 5.0 +/- 2.1, and 3.1 +/- 1.6 (P <.001), (no-CAD versus diffuse-CAD: P <.001; focal-CAD versus diffuse-CAD: P <.001). Multivariate analysis revealed SAEI (P <.001), hypercholesterolemia (P =.005), systolic blood pressure (BP) (P <.001), mean arterial BP (P <.001), pulse pressure (P =.003), and male gender (P =.001) to be diagnostic markers of the type of vessel disease. CONCLUSIONS Compliance measurements may be used for identification of patients with diffuse atherosclerotic processes of the coronary arteries.
Collapse
|
29
|
Wexberg P, Mueck K, Windberger U, Lang S, Osranek M, Weidinger F, Maurer G, Gottsauner-Wolf M. Adventitial response and expansive remodeling after intravascular brachytherapy in a rabbit model of restenosis. J Am Coll Cardiol 2003. [DOI: 10.1016/s0735-1097(03)80158-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
30
|
Wexberg P, Beran G, Lang I, Siostrzonek P, Kirisits C, Glogar D, Gottsauner-Wolf M. Percutaneous interventions in radiation-associated coronary in-stent restenosis. Cardiovasc Intervent Radiol 2003; 26:154-7. [PMID: 12638038 DOI: 10.1007/s00270-002-2644-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This study was performed to evaluate the outcome of percutaneous revascularization in "edge restenoses" developing after radioactive stent implantation in de novo and in-stent lesions. Twenty-one consecutive patients undergoing target lesion revascularization (TLR) at any follow-up after phosphorus-32 radioactive stent implantation were included in this study. We assessed the incidence of death, myocardial infarction, repeated TLR and recurrent angina over the following 18 months. After 6 months, TLR rate was 28.6%, and no stent thromboses, deaths or Q-wave myocardial infarctions occurred. Among the patients with TLR there were significantly more subjects who had received a radioactive stent in a previous in-stent restenosis (66.7% vs. 0% in patients without second restenosis; P <0.001), or who had received two radioactive stents (83.3% vs. 33.3%; P = 0.038). After 18 months, TLR rate was 33.3%, and two patients (9.5%) had died. Restenosis after intravascular radiotherapy can be safely treated by percutaneous interventional techniques, yielding an acceptable clinical result within 18 months.
Collapse
|
31
|
Pfaffenberger S, Devcic-Kuhar B, El-Rabadi K, Gröschl M, Speidl WS, Weiss TW, Huber K, Benes E, Maurer G, Wojta J, Gottsauner-Wolf M. 2MHz ultrasound enhances t-PA-mediated thrombolysis: comparison of continuous versus pulsed ultrasound and standing versus travelling acoustic waves. Thromb Haemost 2003; 89:583-9. [PMID: 12624644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Abstract
In addition to fibrinolytic enzymes, ultrasound has the potential to enhance thrombolysis. High frequency ultrasound has the advantage that a combination of diagnostic and therapeutic ultrasound with only one device is possible. Therefore, we investigated the optimal high frequency (2 MHz) ultrasound field characteristics and application mode in vitro. Continuous ultrasound significantly enhanced rt-PA mediated thrombolysis: in a travelling wave field thrombolysis was augmented by 49.0 +/- 14.7% and in a standing wave field by 34.8 +/- 7.3%. In an intermittent application mode (1Hz, 10Hz, 100Hz, 1kHz) most efficient results were obtained for both wave fields using 1 Hz (46.4 +/- 10.7% and 39.1 +/- 6.6%, respectively). Referring to a possible in vivo application our in vitro data suggests that an intermittent application of a 2 MHz high frequency ultrasound using a travelling wave field would be the most potent application for lysing blood clots.
Collapse
|
32
|
Stiebellehner L, Nikfardjan M, Diem K, Atteneder M, Stulnig T, Priglinger U, Gottsauner-Wolf M, Huber K. [Manual compression versus mechanical compression device (FemoStop) after diagnostic coronary angiography with/without intervention]. Wien Klin Wochenschr 2002; 114:847-52. [PMID: 12503476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2023]
Abstract
BACKGROUND The aim of our study was to evaluate the practicability and the complication rates of two different forms of the post-angiographic closure of the femoral artery. METHODS We randomized 239 patients over a time period of 4 months to either a mechanical compression system (FemoStop, 111 patients) or to conventional manual compression (128 patients). A Doppler-sonographic examination was performed if the patient reported pain of the puncture site, or if auscultation or palpation suspected a complication on the day after compression. RESULTS After manual compression, Doppler-sonography had to be performed in 21 patients (16.4%). In the FemoStop-group only 14 patients (12.6%, p = ns) had to be referred for ultrasound examination. A complication was detected in 13 patients (10.1%) after manual compression and in 5 patients (4.5%, p = ns) after closure with the mechanical device. The incidence of a pseudo-aneurysma or of an arterio-venous fistula did not show any difference between the two groups. In 6 patients of the manual compression group a hematoma was found (p < 0.05), whereas no hematoma occurred in the FemoStop-group. None of the hematomas required the infusion of blood concentrates or surgical correction. In one patient with extreme overweight the mechanical compression device could not be applied. The mechanical compression device was used successfully in patients who had received heparin, acetyl-salicyl-acid or a glycoprotein IIb/IIIa receptor antagonist and in whom a significantly longer compression time and higher complication rate could have been expected. In addition, post-angiographic closure with the was less time consuming for the staff involved. In contrast, the higher cost of the mechanical compression device presents a disadvantage. CONCLUSION A mechanical compression device (FemoStop) can be used successfully in routine post-angiographic management and shows a trend to lower complication rates than manual compression and increased acceptance by patients and physicians. However, the overall costs are higher for the mechanical compression device.
Collapse
|
33
|
Devcic-Kuhar B, Pfaffenberger S, Gröschl M, Kollmann C, Benes E, Gottsauner-Wolf M. In vitro thrombolysis enhanced by standing and travelling ultrasound wave fields. ULTRASOUND IN MEDICINE & BIOLOGY 2002; 28:1181-1187. [PMID: 12401389 DOI: 10.1016/s0301-5629(02)00563-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Success of thrombolytic therapy depends on penetration of recombinant tissue plasminogen activator (rt-PA) into clots. Ultrasound (US) of therapeutic quality accelerates thrombolysis in vitro. As yet, only the effects of travelling acoustic waves on thrombolysis have been investigated, and the impact of standing acoustic waves has been neglected. In the present study, we examined the effects of standing and travelling US wave fields applied continuously for 1 h (frequency 2 MHz, acoustic intensity 1.2 W/cm(2)) on thrombolysis enhancement by measuring clot weight reduction and concentration of fibrin degradation product D-dimer (FDP-DD) produced from clots subjected to rt-PA. The level of FDP-DD was 1.8 times greater in travelling than in standing acoustic waves. Thrombolysis enhancement was 46.0 +/- 20.8% in standing and 116.8 +/- 23.1% in travelling acoustic waves. Travelling waves enhanced thrombolysis significantly more (p < 0.0001) than did standing waves.
Collapse
|
34
|
Gyongyosi M, Sperker W, Windberger U, Gottsauner-Wolf M, Wexberg P, Bonderman D, Lang I, Ferdinandy P, Mariovits S, Giogar D. Intracoronary administration of acetyl-tyrosinyl-valyl-alanyl-aspartyl-chloro-methylketone (Ac-YVAD-cmk) reduces neointimal hyperplasia after stenting of the porcine coronary artery. J Am Coll Cardiol 2002. [DOI: 10.1016/s0735-1097(02)80297-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
35
|
Syeda B, Schmid R, Wexberg P, Kirisits C, Denk S, Beran G, Siostrzonek P, Gottsauner-Wolf M, Lang I, Pokrajac B, Poetler R, Glogar D. Effects of geographic miss during intracoronary brachytherapy on edge stenosis at follow-up. J Am Coll Cardiol 2002. [DOI: 10.1016/s0735-1097(02)80095-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
36
|
Wexberg P, Kirisits C, Gyöngyösi M, Gottsauner-Wolf M, Ploner M, Pokrajac B, Pötter R, Glogar D. Vascular morphometric changes after radioactive stent implantation: a dose-response analysis. J Am Coll Cardiol 2002; 39:400-7. [PMID: 11823076 DOI: 10.1016/s0735-1097(01)01776-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The goal of this study was to evaluate the dose-dependency of morphometric changes in the coronary arterial wall after radioactive stenting. BACKGROUND Radioactive stents have been found to reduce intrastent intimal hyperplasia (IIH) but lead to a characteristic type of restenosis occurring predominantly at the stent edges. METHODS Fifteen patients underwent intravascular ultrasound (IVUS) examination after implantation of a P-32 radioactive stent and at the six-month follow-up. The post-stent IVUS measurements on seven predefined locations of each lesion were subjected to a computer algorithm for the development of dose-volume histograms (DVH). Thus, we derived the radiation doses delivered to at least 10% and 90% of the adventitia (DV10, DV90). The IIH and vascular remodeling at follow-up were correlated with the doses in each segment. RESULTS The IIH was most pronounced at the stent edges and lowest in the stent-body, whereas we detected a significant expansive remodeling within the stent body. The delivered doses correlated with a decreased IIH (r = 0.52, p < 0.001 for DV10 and r = 0.62, p < 0.001 for DV90) and with expansive remodeling (r = 0.48, p = 0.009 for DV10 and r = 0.50, p = 0.006 for DV90). A DV10 >90 Gy or a DV90 >15 Gy reduced IIH and induced expansive remodeling. Plaque growth was not reduced by radioactive stents. CONCLUSIONS The DVH analysis reveals a dose-dependent increase of external elastic lamina area behind radioactive stents, whereas plaque growth is not reduced but inverted into an outward direction from the stent. A DV10 >90 Gy or a DV90 >15 Gy results in a beneficial long-term outcome after radioactive stenting.
Collapse
|
37
|
el-Rabadi K, Gottsauner-Wolf M, Christ G, Maurer G, Huber K. [Chlamydia antibody titers in patients with coronary disease: relations to age and clinical stage]. Wien Klin Wochenschr 2001; 113:727-30. [PMID: 11715750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
BACKGROUND AND AIM Atherosclerosis and its clinical sequelae are responsible for the highest death rate in industrialized countries. Seroepidemiological, pathological and immunohistochemical studies have suggested a relation between Chlamydia pneumoniae infection and the development of coronary sclerosis. Aim of this study was to investigate the frequency distribution of Chlamydia pneumoniae antibody titers in patients with different clinical stages of coronary artery disease (CAD) and patients without CAD as well as a possible age dependence of antibody titers within the study groups. For this purpose, 522 consecutive patients of a cardiology ward were investigated, over a period of 10 months, for the presence of Chlamydia pneumoniae antibodies (IgG, IgA, IgM) using specific ELISA's. In general, there was no difference in the frequency of positive Chlamydia antibody titers between CAD patients and the control group. Only in the subgroup of unstable CAD-patients < 50 years a tendency of increased antibody titers was present. Patients with stable angina, unstable angina, or acute myocardial infarction exhibited no significant differences in the rate of infection between the different age groups (p < 0.117). In contrast, there was a significant increase in positive Chlamydia pneumoniae antibodies with increasing age in the control group (p = 0.002). The relatively high incidence of positive Chlamydia pneumoniae antibody titers in young CAD patients, which is associated with a loss of age-dependent increase of the antibody titers in the CAD group, might indicate a specific role of Chlamydia pneumoniae infections for the manifestation of premature CAD (before the age of 50). Due to the increased rate of Chlamydia pneumoniae infections with increasing age, the determination of Chlamydia pneumoniae antibody titers does not allow reliable conclusions on the infectious pathogenesis of CAD. Furthermore, our unability to demonstrate differences in antibody titers between CAD patients with stable angina, unstable angina, and acute myocardial infarction suggests that acute Chlamydia pneumoniae infections are not responsible for the development of acute coronary syndromes.
Collapse
|
38
|
Anvari A, Schuster E, Gottsauner-Wolf M, Wojta J, Huber K. PAI-I 4G/5G polymorphism and sudden cardiac death in patients with coronary artery disease. Thromb Res 2001; 103:103-7. [PMID: 11457467 DOI: 10.1016/s0049-3848(01)00277-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
UNLABELLED The 4G/5G polymorphism of the plasminogen activator inhibitor type I (PAI-I) gene is involved in coronary artery disease (CAD), with the highest risk in 4G/4G homozygotes. The role of PAI-I polymorphism in patients suffering from CAD and history of sudden cardiac death (SCD) has not been addressed yet. We studied the frequency distribution of the PAI-I gene to test the hypothesis that the 4G/4G genotype favors myocardial ischemia and, even in the absence of acute infarction, promotes SCD in patients with CAD. METHODS The PAI-I 4G/5G genotypes and PAI-I antigen plasma levels were determined in 97 patients with CAD and a history of SCD treated with an implantable cardioverter defibrillator (ICD) (defibrillator group) comparing to 113 patients with CAD but no history of SCD (control group). RESULTS The defibrillator group consisted of significantly more 4G/4G homozygotes and higher PAI-I levels than the control group (44% vs. 24%, 173+/-41 vs. 144+/-49 ng/ml; P<.01). The carriers of 4G allele had a significantly higher risk for SCD (odds ratio (OR) 1.9) with the highest risk in the 4G/4G genotype (OR 3.6, P<.01). CONCLUSION These results suggest that the PAI-I 4G/4G genotype is associated with SCD in patients suffering from CAD.
Collapse
MESH Headings
- Aged
- Alleles
- Case-Control Studies
- Coronary Disease/complications
- Death, Sudden, Cardiac/epidemiology
- Death, Sudden, Cardiac/etiology
- Death, Sudden, Cardiac/prevention & control
- Defibrillators, Implantable/statistics & numerical data
- Electrocardiography
- Female
- Gated Blood-Pool Imaging
- Gene Frequency
- Genetic Predisposition to Disease
- Genotype
- Humans
- Likelihood Functions
- Male
- Middle Aged
- Odds Ratio
- Plasminogen Activator Inhibitor 1/genetics
- Polymorphism, Genetic
- Promoter Regions, Genetic/genetics
- Regression Analysis
- Risk Factors
- Survival Analysis
- Tachycardia, Ventricular/complications
- Tachycardia, Ventricular/prevention & control
- Ventricular Fibrillation/complications
- Ventricular Fibrillation/prevention & control
Collapse
|
39
|
Wexberg P, Gottsauner-Wolf M, Sulzbacher I, Birner P, Laggner A, Glogar D. Fatal late coronary thrombosis after implantation of a radioactive stent: postmortem angiographic and histologic findings--case report. Radiology 2001; 220:142-4. [PMID: 11425986 DOI: 10.1148/radiology.220.1.r01jl19142] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Postmortem angiography and histologic analysis of a fatal coronary thrombosis 4 months after implantation of a radioactive stent are described. Histologic findings suggested incomplete re-endothelialization in the segment with the stent. Ionizing radiation may delay re-endothelialization after revascularization, thus maintaining the thrombogenicity of the irradiated vessel segment. Thus, prolonged antiplatelet therapy should be considered after intravascular radiation therapy.
Collapse
|
40
|
Gyongyosi M, Sperker W, Lang I, Bonderman D, Gottsauner-Wolf M, Wexberg P, Glogar D. Inhibition of apoptosis reduces neointimal hyperplasia after stent implantation in porcine coronary artery. J Mol Cell Cardiol 2001. [DOI: 10.1016/s0022-2828(01)90170-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
41
|
Kirisits C, Wexberg P, Gottsauner-Wolf M, Pokrajac B, Ortmann E, Aiginger H, Glogar D, Pötter R. Dose–volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents. Radiother Oncol 2001; 59:329-37. [PMID: 11369076 DOI: 10.1016/s0167-8140(00)00239-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
BACKGROUND AND PURPOSE Radioactive stents are under investigation for reduction of coronary restenosis. However, the actual dose delivered to specific parts of the coronary artery wall based on the individual vessel anatomy has not been determined so far. Dose-volume histograms (DVHs) permit an estimation of the actual dose absorbed by the target volume. We present a method to calculate DVHs based on intravascular ultrasound (IVUS) measurements to determine the dose distribution within the vessel wall. MATERIALS AND METHODS Ten patients were studied by intravascular ultrasound after radioactive stenting (BX Stent, P-32, 15-mm length) to obtain tomographic cross-sections of the treated segments. We developed a computer algorithm using the actual dose distribution of the stent to calculate differential and cumulative DVHs. The minimal target dose, the mean target dose, the minimal doses delivered to 10 and 90% of the adventitia (DV10, DV90), and the percentage of volume receiving a reference dose at 0.5 mm from the stent surface cumulated over 28 days were derived from the DVH plots. Results were expressed as mean+/-SD. RESULTS The mean activity of the stents was 438+/-140 kBq at implantation. The mean reference dose was 111+/-35 Gy, whereas the calculated mean target dose within the adventitia along the stent was 68+/-20 Gy. On average, DV90 and DV10 were 33+/-9 Gy and 117+/-41 Gy, respectively. Expanding the target volume to include 2.5-mm-long segments at the proximal and distal ends of the stent, the calculated mean target dose decreased to 55+/-17 Gy, and DV 90 and DV 10 were 6.4+/-2.4 Gy and 107+/-36 Gy, respectively. CONCLUSIONS The assessment of DVHs seems in principle to be a valuable tool for both prospective and retrospective analysis of dose-distribution of radioactive stents. It may provide the basis to adapt treatment planning in coronary brachytherapy to the common standards of radiotherapy.
Collapse
|
42
|
Gottsauner-Wolf M, Zasmeta G, Hornykewycz S, Nikfardjam M, Stepan E, Wexberg P, Zorn G, Glogar D, Probst P, Maurer G, Huber K. Plasma levels of C-reactive protein after coronary stent implantation. Eur Heart J 2000; 21:1152-8. [PMID: 10924298 DOI: 10.1053/euhj.1999.1987] [Citation(s) in RCA: 91] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS This study was designed to investigate the role of inflammation on the occurrence of angiographic restenosis 6 months after coronary stent implantation and the influence of different kinds of antithrombotic and antiplatelet strategies on inflammation. METHODS AND RESULTS In an open randomized trial, 40 consecutive patients were treated with aspirin (100 mg. day(-1)) and either ticlopidine (2x250 mg. day(-1)) (n=17), or phenprocoumon (INR 2.0-3.0) and dipyridamole (3x160 mg. day(-1)) (n=23) after successful elective coronary stent implantation. Plasma levels of C-reactive protein were determined one day before stent implantation and serially thereafter twice daily up to 120 h. C-reactive protein plasma levels increased significantly (P<0.0001) after stent implantation. Phenprocoumon and dipyridamole or ticlopidine had no effect on C-reactive protein plasma levels (P=0.51) or the occurrence of angiographic restenosis (P=0.48). C-reactive protein plasma levels were significantly higher in patients with lesion type C compared to types A or B (P=0.035), respectively. C-reactive protein plasma levels were significantly higher and mean shoulder levels occurred 48 h later in patients with restenosis compared to patients without restenosis after 6 months (P=0.038). CONCLUSIONS Elevated C-reactive protein plasma levels still persisting 96 h after stent implantation might reflect a prolonged inflammatory reaction to coronary stent implantation which might causally be involved in pathophysiological mechanisms leading to restenosis.
Collapse
|
43
|
Wexberg P, Gottsauner-Wolf M. Intravascular radiotherapy: restenosis and more? Heart 2000; 83:497-8. [PMID: 10768894 PMCID: PMC1760803 DOI: 10.1136/heart.83.5.497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
|
44
|
Gottsauner-Wolf M, Wexberg P, el-Rabadi K, Wojta J, Maurer G, Huber K. [Atherosclerosis: an infectious disease?]. Wien Klin Wochenschr 2000; 112:253-9. [PMID: 10815300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
45
|
Mück K, Schmidt W, Wexberg P, Görz W, Maurer G, Gottsauner-Wolf M. Design and dosimetry of a novel 90Y beta source to prevent restenosis after angioplasty. Int J Radiat Oncol Biol Phys 2000; 46:249-55. [PMID: 10656399 DOI: 10.1016/s0360-3016(99)00350-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE Post-dilatation irradiation of the vessel wall is currently under investigation for prevention of restenosis after balloon dilatation. For the irradiation, special sources were designed for animal experiments which would give equivalent irradiation conditions and doses to the vessel wall that would later be employed for human application. METHODS AND MATERIALS For the planned irradiations, a specially designed yttrium-wire of 0.45-mm diameter coated with a thin shrink tube to prevent contamination was deployed. Several leakage tests applied before and after application proved that the irradiation source was leakproof. Dosimetry was performed by using 0.1-mm-thick thermoluminescent dosimeters (TLD-100) calibrated against a primary standard. A shielding transport and application container was designed to facilitate the handling of the source during use, while reducing exposure of the medical personnel. RESULTS The designed source proves to be flexible for the insertion into proximal coronary vessels, and positioning at the site of stenosis. It provides an optimum protection of the animal and requires little radiation protection efforts on behalf of the medical staff. Dosimetric calculations and measurements showed that a centering of the source inside the vessel could be achieved with a maximum deviation of 50% between maximum and average dose levels. CONCLUSION A yttrium-90 beta brachytherapy source was designed which provides high flexibility within proximal coronary arteries, ensures an adequate centering inside the artery, and provides irradiation conditions to the vessel wall of the experimental animal comparable to the application inside a human artery.
Collapse
|
46
|
Deicher R, Nikfardjam M, Woisetschläger C, Gottsauner-Wolf M, Huber K. [Acute coronary syndromes: physiopathology and therapeutic aspects]. ACTA MEDICA AUSTRIACA 1999; 26:70-82. [PMID: 10478281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
This article discusses recent developments in the field of acute coronary syndromes including pathophysiological mechanisms as well as therapeutic strategies. A plaque disruption is caused by different stimuli in a plaque prone to rupture, i.e. a plaque with a lipid-rich core and high local concentration of inflammatory cells (T-cells, monocytes/macrophages, mast cells). These cells are capable of producing matrix degradation products and can reduce stability of a plaque. Thrombus formation, based on platelet activation and aggregation as well as fibrin formation, is the main consequence of plaque disruption. Depending on the degree of thrombus formation occlusion is followed clinically by unstable angina (subtotal occlusion) or by acute myocardial infarction (total occlusion). Accompanying vasoconstriction may further aggravate the situation. Principles of therapy are thrombus dissolution as well as prevention of new thrombus formation: main goals of thrombolytic therapy in acute myocardial infarction are a prompt (less than 3 hours), complete, and sustained (prevention of early thrombotic reocclusion) reperfusion.
Collapse
|
47
|
Anvari A, Türel Z, Schmidt A, Yilmaz N, Mayer G, Huber K, Schuster E, Gottsauner-Wolf M. Angiotensin-converting enzyme and angiotensin II receptor 1 polymorphism in coronary disease and malignant ventricular arrhythmias. Cardiovasc Res 1999; 43:879-83. [PMID: 10615414 DOI: 10.1016/s0008-6363(99)00143-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVES It has been reported that patients carrying the angiotensin-converting enzyme (ACE) deletion DD genotype with the angiotensin II type 1 (AT1) C allele are at increased risk for myocardial infarction. The frequency distribution of the ACE and AT1 receptor gene polymorphism and their possible relation regarding malignant ventricular arrhythmias in patients with coronary artery disease (CAD) and left ventricular dysfunction was determined. METHODS The ACE I/D and AT1 A/C polymorphisms (using polymerase chain reaction) in 100 Caucasian patients suffering from CAD with a history of malignant ventricular arrhythmias treated with an implantable cardioverter defibrillator (ICD group) was compared to 127 age-matched Caucasian patients with CAD and no history of malignant ventricular arrhythmias (control group). All patients had reduced left ventricular ejection fraction of < 40% and were comparable regarding sex distribution, body mass index, ACE-inhibitor treatment, lipid status and duration of CAD. RESULTS The prevalence of DD/CC in the ICD group was significantly higher (19% versus 10%, p < 0.0001). The risk for malignant ventricular arrhythmias was associated with the combination of ACE D and AT1 C alleles (odds-ratio: 2.4, 95% confidence interval 1.41 to 3.94, p < 0.001). The distribution of ACE and AT1 genotypes was not different between the two group. CONCLUSIONS Patients with coronary artery disease and left ventricular dysfunction carrying ACE D and AT1 C alleles are at increased risk for development of malignant ventricular arrhythmias. Because of available pharmacological inhibitors, these results may have clinical implications for the prevention of sudden cardiac death.
Collapse
|
48
|
Gottsauner-Wolf M, Sochor H, Hornykewycz S, Beckmann R, Lang I, Probst P, Binder BR, Huber K. Predictive value of PAI-1 plasma activity and thallium perfusion imaging for restenosis after percutaneous transluminal angioplasty in clinically asymptomatic patients. Thromb Haemost 1999; 81:522-6. [PMID: 10235432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
BACKGROUND The main long-term complication of percutaneous transluminal coronary angioplasty (PTCA) is restenosis that occurs in 30-50 percent of all primary successful cases. The purpose of this study was to evaluate the predictive value of changes in plasminogen activator inhibitor-1 (PAI-1) activity and of thallium dipyridamole perfusion imaging performed 3 months after successful angioplasty. All patients were asymptomatic at evaluation. The results of these two noninvasive tests were compared with the angiographic outcome after 6 months. METHOD AND PATIENTS Twenty-five patients were included in this prospective study. All patients had single vessel disease, successful angioplasty and were free of clinical symptoms 3 months after angioplasty that would suggest late restenosis. In 12/25 patients (48%) angiographic restenosis (percent diameter stenosis >50%) was determined by follow-up angiography 6 months after angioplasty. PAI-1 plasma activity was determined by a functional titration assay and increase or decrease of PAI-1 plasma activity was evaluated between values obtained before and 3 months after angioplasty. In 7/25 (28%) patients PAI-1 plasma activity increased to more than 90% of pre-angioplasty values. This increase correlated with angiographic restenosis evaluated 6 months after angioplasty (sensitivity 42%, specificity 85%, positive predictive value 71%, and negative predictive value 61%). T1-201-perfusion imaging was performed 3 months after angioplasty. This test was indicative for subsequent restenosis in 5/25 patients (sensitivity 33%, specificity 100%, positive predictive value 62%, and negative predictive value 100%). In 10/25 (40%) patients at least one of the two non-invasive tests performed 3 months after angioplasty predicted angiographic restenosis at 6 months: the combined use of PAI-1 and T1-201-perfusion imaging resulted in increased sensitivity (67%) and high specificity (85%). CONCLUSION The results of this study indicate that an increase of PAI-1 plasma activity may improve the predictive value for restenosis of T1-201-scintigraphy performed 3 months after angioplasty even in asymptomatic patients.
Collapse
|
49
|
Anvari A, Gottsauner-Wolf M, Türel Z, Stix G, Podesser B, Mayer C, Schuster E, Schmidinger H. Predictors of outcome in patients with implantable cardioverter defibrillators. Cardiology 1998; 90:180-6. [PMID: 9892766 DOI: 10.1159/000006841] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
UNLABELLED This study determined the impact of clinical characteristics on shock occurrence and survival in patients with implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS During a follow-up of 27 +/- 18 months, the actuarial incidence of appropriate shocks in 200 consecutive patients was 18, 36 and 72% at 1, 3, and 5 years, respectively. Coronary artery disease was the only significant predictor for shock occurrence (relative risk 1.32, p = 0.03). The actuarial incidence of total mortality was 10, 17 and 33% at 1, 3, and 5 years, respectively. The most powerful predictors for total mortality were: New York Heart Association functional class (NYHA) III (relative risk 4.8, p = 0.001) and a history of congestive cardiac failure (relative risk 3.6, p = 0.01). CONCLUSION During long-term follow-up, the majority of patients receive appropriate shocks. No strong predictors for shock occurrence can be identified from the data analyzed. A history of congestive cardiac failure and the NYHA III are the most powerful predictors for total mortality. These clinical factors may provide valuable criteria to identify patients who will benefit from the implantation of ICD.
Collapse
|
50
|
Banyai S, Streicher J, Strobl W, Gabriel H, Gottsauner-Wolf M, Rohac M, Weidinger F, Hörl WH, Derfler K. Therapeutic efficiency of lipoprotein(a) reduction by low-density lipoprotein immunoapheresis. Metabolism 1998; 47:1058-64. [PMID: 9751233 DOI: 10.1016/s0026-0495(98)90278-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
This study was performed to investigate the effect of low-density lipoprotein (LDL) immunoapheresis on lipoprotein(a) [Lp(a)] reduction in patients with heterozygous and homozygous familial hyperlipidemia (N=16) and insufficient response to lipid-lowering agents. By desorption of approximately 5,700+/-500 mL of plasma, a mean reduction in total cholesterol of 62% (P < .001) and in LDL-cholesterol of 70% (P < .001) was achieved. Lp(a), which was elevated at study entry in seven of these patients (82.1+/-34.3 mg/dL; range, 48 to 148 mg/dL), was reduced during the initial LDL-apheresis procedure by 74.8%+/-14.1% (P < .001). Long-term apheresis treatment performed at weekly intervals resulted in an mean reduction in Lp(a) pretreatment values to 39.1+/-28.5 mg/dL (-54%; P < .001). Desorbed Lp(a) was measured at the waste of the columns for 31 apheresis treatments. Lp(a) concentration of the column waste was higher in patients with elevated serum Lp(a) pretreatment values as compared with those with Lp(a) serum values within the normal range (elevated Lp(a), 1,420+/-380 mg; without elevated Lp(a), 235+/-190 mg; P < .001). The rate of return of Lp(a) following apheresis treatment scheduled at weekly intervals was comparable to that of LDL-cholesterol.
Collapse
|