26
|
Hirai M, Muramatsu Y, Mizuno S, Kurahashi N, Kurahashi H, Nakamura M. Intact attentional orienting towards inverted faces revealed by both manual responses and eye-movement measurement in individuals with Williams syndrome. JOURNAL OF INTELLECTUAL DISABILITY RESEARCH : JIDR 2016; 60:969-981. [PMID: 27476718 DOI: 10.1111/jir.12318] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Revised: 06/10/2016] [Accepted: 06/22/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND Individuals with Williams syndrome (WS) exhibit atypical attentional characteristics when viewing faces. Although atypical configural processing of faces has been reported in WS, the relative strengths of configural and local feature information to capture visual attention in WS remains unclear. We previously demonstrated that attentional capture by target-unrelated upright faces differs depending on what response is measured. Whereas eye movements reflected subtle atypical attentional properties at the late stage of visual search, manual responses could not capture the atypical attentional profiles towards target-unrelated upright faces in individuals with WS. Here we used the same experimental paradigm to assess whether sensitivity to configural facial information is necessary for capturing attention in WS. METHODS We measured both eye movements and manual responses from 17 individuals with WS and 34 typically developing children and adults while they were actively involved in a visual search task with an inverted face distractor. Task measures (reaction time and performance accuracy) and gaze behaviour (initial direction of attention and fixation duration) were analysed for each stimulus. RESULTS When the target and the inverted face were displayed in the same search array, reaction times and accuracies in individuals with WS showed similar tendencies as typical controls. Analysis of task and gaze measures revealed that attentional orienting towards inverted faces was not atypical. CONCLUSION Although individuals with WS exhibited atypical gaze behaviour towards upright faces in our previous study, this unusual behaviour disappears if the faces are upside down. These findings suggest that local feature information alone (e.g. eyes) does not contribute to the heightened attention to faces, but configural information appears necessary for drawing attention to faces in individuals with WS, at least in the current experimental paradigm.
Collapse
|
27
|
Ueno M, Miyoshi M, Matsuo M, Yamashita H, Kajita A, Hamada Y, Takahashi M, Yamamoto M, Yamamoto I, Mikajiri R, Tabuchi S, Wakida K, Yamanishi M, Hirai M, Usami M. SUN-P007: Effect of Dietary Fatty Acids and Micronutrients Intake on Serum Diamine Oxidase Activity in Healthy Women. Clin Nutr 2016. [DOI: 10.1016/s0261-5614(16)30350-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
28
|
Kitahara H, Hirai M, Nakamura H, Kawashiri S. Eribulin differentiates cetuximab resistant oral squamous cell carcinoma cells to sensitive by inducing mesenchymal–epithelial transition (MET). Eur J Cancer 2016. [DOI: 10.1016/s0959-8049(16)61183-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
29
|
Hirai M. Changes in Interface Pressure under Elastic and Short-Stretch Bandages during Posture Changes and Exercise. Phlebology 2016. [DOI: 10.1177/026835559801300106] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objective: To evaluate the pressure under short-stretch and elastic bandages. Design: Prospective study in 20 healthy volunteers, comparing the two different kinds of bandages. Setting: Department of Surgery, Aichi Prefectural College of Nursing, Nagoya, Japan. Main outcome measures: Pressure measurements were made beneath the bandages with different initial pressures of 10, 20, 30, 40, 50, 60, and 70 mmHg, during supine resting, standing, tip-toe exercise and walking. Results: Short-stretch bandages showed a significant increase in pressure during standing and exercise at lower initial pressures compared with elastic bandages. In analysing the pressure waveform during tip-toe exercise and walking, a significantly greater pressure difference between muscle contraction and relaxation was noted for short-stretch bandages compared with elastic bandages at any initial pressures. Conclusions: Short-stretch bandages produce a higher working pressure and a larger pressure difference during exercise. However, the effect depends on the initial pressures at the time of application. In clinical practice, prevention of a decrease in pressure with time and uniform application of bandages are important.
Collapse
|
30
|
Abstract
Objective: To investigate the clinical significance of corona phlebectatica. Design: Clinical and plethysmographic evaluation of corona phlebectatica associated with primary varicose veins. Setting: Department of Surgery, Aichi Prefectural College of Nursing, Nagoya, Japan. Main outcome measures: In 411 limbs with greater saphenous incompetence, including 101 with skin changes and 310 without skin changes, clinical analysis and plethysmographic evaluation using the photoplethysmographic technique were carried out. Results: In 204 of 411 limbs, corona phlebectatica was observed, including 75 coloured red and 129 coloured blue. Blue coronas were observed significantly more often then red coronas in limbs with skin changes. The half refilling time in limbs with skin changes was significantly shorter than that in limbs without skin changes. In limbs without skin changes, limbs with blue coronas showed a significantly shortened half refilling time than those with red coronas. Conclusions: Blue coronas are a strong indicator of the presence of prolonged venous hypertension in varicose veins.
Collapse
|
31
|
Hirai M. Interface Pressure under Elastic Stockings with Compression Pads during Posture Changes and Exercise. Phlebology 2016. [DOI: 10.1177/026835559901400207] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objective: To quantify the influence of posture and exercise on the interface pressure obtained under elastic stockings with compression pads. Design: Interface pressure measurement and plethysmographic evaluation of elastic stockings with and without compression pads. Setting: Department of Surgery, Aichi Prefectural College of Nursing, Nagoya, Japan. Main outcome measures: Pressure measurements in 24 volunteers were obtained beneath elastic stockings, elastic bandages and short-stretch bandages during supine resting, standing, tip-toe exercise and walking, and the effect of elastic stockings on the muscle pump of the leg was evaluated by strain-gauge plethysmography in 40 limbs with varicose veins. Results: Without compression pads, only short-stretch bandages showed a significant increase in pressure during standing and exercise. When pads were used, however, elastic stockings and bandages also showed a significant increase. With pads, significant improvement in the expelled volume during exercise was observed by strain-gauge plethysmography. Conclusions: Interface pressure under elastic materials during posture and exercise is similar to that under short-stretch bandages when compression pads are used, and pads effectively augment the muscle pump.
Collapse
|
32
|
Hirai M, Iwata H. A comparison of physical methods for prophylaxis of deep vein thrombosis on augmentation of venous flow velocity and reduction of calf volume. Phlebology 2016. [DOI: 10.1258/026835504323080344] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Objective: This study was designed to determine the optimal physical methods for promoting venous return of the leg. Methods: Ten healthy volunteers were investigated in the supine position on a couch, and their peak femoral venous velocity and calf muscle volume were determined using duplex ultrasound and strain gauge plethysmography,respectively,before and during deep respiration, limb elevation, calf squeezing and various types of leg exercises. Results: Deep respiration showed the smallest effect on both percentage increase of peak flow velocity and expelled volume. Elevation of the leg showed the same effect on the expelled volume as calf muscle squeezing and ankle movement, while the former showed significantly less effect than the latter on the percentage increase of peak flow velocity. In both dorsal flexion of the ankle and squeezing at the calf, the stronger of each procedure caused more effective changes in haemodynamics. Ankle exercise was more effective in promoting venous return in the calf muscle than wiggling the toes, making circling movements with the feet or alternately flexing and spreading the toes. Conclusions: Ankle exercise or calf muscle squeezing, performed maximally,may be the first recommendation for reducing venous stasis at the calf muscle and prophylaxis of deep vein thrombosis..
Collapse
|
33
|
Hirai M, Sato S, Kimura R, Hagiwara Y, Kawai-Hirai R, Ohta N, Igarashi N, Shimizu N. Effect of protein-encapsulation on thermal structural stability of liposome composed of glycosphingolipid/cholesterol/phospholipid. J Phys Chem B 2015; 119:3398-406. [PMID: 25642599 DOI: 10.1021/jp511534u] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We have studied the thermal structural stability of liposomes encapsulating proteins by using synchrotron radiation small- and wide-angle X-ray scattering (SR-SWAXS). Liposomes are known to be effective drug-delivery systems (DDSs) because they can reduce drug toxicity due to biodegradability and biocompatibility and can offer promising carriers of various types of drugs. However, in spite of numerous studies of liposomes, physicochemical characteristics of liposomes entrapping proteins are rarely known. The liposome studied is characterized by the lipid composition (mixture of acidic glycosphingolipid (ganglioside)/cholesterol/phospholipid). Gangliosides are one of the major constituents of so-called lipid rafts playing the role of a platform of cell-signaling. We have found that the encapsulation of proteins elevates the thermal transition temperature of the liposome membrane and suppresses the deformation of its shape. The present results suggest that not only membrane proteins, but also water-soluble proteins affect liposome stability through the revalence between osmotic pressure and membrane elasticity. In addition, we have found the presence of the size-effect depending on the molar content of gangliosides in the liposome, indicating the ability of ganglioside molecule controlling both the size and effective surface charge of the liposome. The present results would have significance from two different points of view. One is the confinement effect of proteins within a limited space like cell, and the other is a stability of a new type of DDS using gangliosides. Due to the intrinsic properties, gangliosides are expected to be promising agents for targeting and long-circulation properties of liposomal DDSs.
Collapse
|
34
|
Okuda H, Yamamoto T, Takeshita K, Hirai M, Sakurai SI, Kitajima Y, Igarashi N, Shimizu N, Ogawa H. ASAXS measurements with soft (tender) X-rays to control the contrast. Acta Crystallogr A Found Adv 2014. [DOI: 10.1107/s2053273314084186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
The structure and properties of thin soft matter materials might be better examined in detail by scattering measurements when the contrast between the materials and penetration depth are tunable. In the so-called tender X-ray region, there are several elements of interest for small-angle scattering measurements, such as Mg, Al, Si, P, and S. We worked on GISAXS measurements at K absorption edges of Si and P to control contrast and penetration depth for thin block copolymer (SEBS) samples and phospholipid alloy systems comprising of phospholipid (PC, DPPC), cholesterol, and ganglioside, and SAXS at Al for Al alloys. The photon energy used in the present measurements is soft enough to give large anomalous effect in the real part of refractive indices for light elements, yet hard enough so that the scattering vector required for nanostructure analysis can be covered. By choosing the photon energy at the K absorption edge of Si, the contrast between Si substrate and polymer thin film can be suppressed, thereby suppressing dynamical effect in GISAXS intensity caused by reflected beam[1]. Combined with the depth sensitive analysis, this is useful to examine the nanostructures that are changing with the distance from the surface. Concerning the contrast change inside the thin films, change of the GISAXS intensities from PC (phosphatidylcholine)-cholestrol-ganglioside (GD1) films spin-cast on Si substrates have been examined at the K absortpion edge of P [2]. ASAXS for P has been examined by Stuhrmann and coworkers[3], but the number of works after them is not large. Present measurements using image plates showed that the hexagonal phase appearing in dried phospholipid alloy films suggests a contrast reversal with the photon energy.
Collapse
|
35
|
Maeda K, Higa S, Nakahara H, Kawamoto K, Mori H, Nozato S, Hirai M, Matsuoka H, Kuritani T, Igarashi T. FRI0330 C-Reactive Protein Does not Elevate in Half of Pneumonia Cases for the Entire Observation Period of Pneumonia during TOCILIZUMAB Treatment for Rheumatoid Arthritis. Ann Rheum Dis 2014. [DOI: 10.1136/annrheumdis-2014-eular.3072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
36
|
Nakahara H, Kawamoto K, Mori H, Nozato S, Hirai M, Matuoka H, Higa S, Fusama M, Takeuchi E, Igarashi T, Kuritani T, Sano H, Maeda K. AB0485 Tocilizumab is Effective for the Patient with Sjogren's Syndrome Complicated with Rheumatoid Arthritis. Ann Rheum Dis 2014. [DOI: 10.1136/annrheumdis-2014-eular.4416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
37
|
Sugiyama M, Yagi H, Yamaguchi T, Kumoi K, Hirai M, Oba Y, Sato N, Porcar L, Martel A, Kato K. Conformational characterization of a protein complex involving intrinsically disordered protein by small-angle neutron scattering using the inverse contrast matching method: a case study of interaction between α-synuclein and PbaB tetramer as a model chaperone. J Appl Crystallogr 2014. [DOI: 10.1107/s1600576713033475] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Cumulative genomics and proteomics data have now highlighted the presence of intrinsically disordered proteins (IDPs), which are devoid of stable secondary or tertiary structures under physiological conditions. While the flexible nature of IDPs precludes their study by crystallographic methods, IDP interactions with their cognate proteins, during which the IDPs often form their secondary structures, have been characterized by nuclear magnetic resonance (NMR) spectroscopy. In view of this, a complementary small-angle neutron scattering (SANS) technique has been developed for probing IDP conformations in larger protein complexes. As a model interaction system, α-synuclein (αSN) bound to an archaeal homotetrameric chaperone, PbaB, was analyzed. To selectively observe the SANS profile of αSN in the complex, the bacterially produced PbaB was fractionally (75%) deuterated using D2O and deuterated glucose for contrast matching to approximately 100% D2O solvent. By employing 75%-deuterated PbaB, the conformational changes of αSN upon capture by this tetrameric chaperone were successfully observed with minimal background scattering. Together with the present NMR data, the SANS data reveal that the PbaB tetramer grasps the N-terminal segments of αSN, disrupting the residual ordered structure in this region, while leaving the remaining regions flexible within a slightly reduced conformational space.
Collapse
|
38
|
Hirai M, Kimura R, Takeuchi K, Hagiwara Y, Kawai-Hirai R, Ohta N, Igarashi N, Shimuzu N. Structure of liposome encapsulating proteins characterized by X-ray scattering and shell-modeling. JOURNAL OF SYNCHROTRON RADIATION 2013; 20:869-74. [PMID: 24121330 PMCID: PMC3795546 DOI: 10.1107/s0909049513020827] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Accepted: 07/25/2013] [Indexed: 05/25/2023]
Abstract
Lipid liposomes are promising drug delivery systems because they have superior curative effects owing to their high adaptability to a living body. Lipid liposomes encapsulating proteins were constructed and the structures examined using synchrotron radiation small- and wide-angle X-ray scattering (SR-SWAXS). The liposomes were prepared by a sequential combination of natural swelling, ultrasonic dispersion, freeze-throw, extrusion and spin-filtration. The liposomes were composed of acidic glycosphingolipid (ganglioside), cholesterol and phospholipids. By using shell-modeling methods, the asymmetric bilayer structure of the liposome and the encapsulation efficiency of proteins were determined. As well as other analytical techniques, SR-SWAXS and shell-modeling methods are shown to be a powerful tool for characterizing in situ structures of lipid liposomes as an important candidate of drug delivery systems.
Collapse
|
39
|
Ikuta T, Hamada Y, Yamaguchi T, Kitamura N, Hirai M, Usami M. PP139-MON THE CHARACTERISTICS OF HYPONATREMIA IN PATIENTS WITH MALNUTRITION: OBSERVATIONAL STUDY USING MULTI-FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS. Clin Nutr 2013. [DOI: 10.1016/s0261-5614(13)60450-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
40
|
Takahashi H, Mizuta T, Oeda S, Isoda H, Nakashita S, Kawaguchi Y, Izumi N, Hirai M, Kurose K, Iwane S, Eguchi Y, Kimura S, Anzai K, Ozaki I. An automated rapid detection system using the quenching probe method for detecting interleukin 28B and inosine triphosphatase single nucleotide polymorphisms in chronic hepatitis C. J Viral Hepat 2013; 20:e124-6. [PMID: 23490380 DOI: 10.1111/jvh.12026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2012] [Accepted: 10/01/2012] [Indexed: 12/09/2022]
Abstract
Single nucleotide polymorphisms (SNPs) in the interleukin 28B gene (IL28B) are good pretreatment predictors of anti-hepatitis C virus (HCV) therapy with interferon. SNPs of the inosine triphosphatase (ITPA) gene are associated with reduced haemoglobin levels during treatment with ribavirin. The i-densy™ (Arkray, Inc.), which is based on the quenching probe (QP) method, automatically detects target genes in blood samples by fluorescence quenching within 100 min. Using a QP and primer set, a gene amplification response is generated that can quickly and easily detect a specific gene's arrangement by fluorometry. The present study was conducted to compare the utility of i-densy (QP method) with that of conventional direct sequencing (DS) for detecting SNPs in the IL28B and ITPA genes in chronic hepatitis C patients. Between June 2011 and January 2012, 73 consecutive patients underwent genotyping of IL28B, and 54 patients underwent genotyping of ITPA. All of the patients were seropositive for HCV-RNA. The IL28B and ITPA genotypes were tested for bi-allelic polymorphisms in rs8099917 (T/T, T/G and G/G; minor allele, G) and rs1127354 (C/C, C/A and A/A; minor allele, A), respectively. The results obtained with the QP method were identical to those obtained with the conventional DS method. The frequency of the IL28B genotypes TT, GT and GG were 74%, 24.7% and 1.4%, respectively, and those of the ITPA genotypes CC, AC and AA were 68.5%, 29.6% and 1.9%, respectively. These results indicate that the i-densy using the QP method can automatically, quickly and easily identify genotypes of IL28B and ITPA.
Collapse
|
41
|
Sai K, Hanatani T, Azuma Y, Segawa K, Tohkin M, Omatsu H, Makimoto H, Hirai M, Saito Y. Development of a detection algorithm for statin-induced myopathy using electronic medical records. J Clin Pharm Ther 2013; 38:230-5. [DOI: 10.1111/jcpt.12063] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Accepted: 03/07/2013] [Indexed: 11/29/2022]
|
42
|
Hirai M, Iwata H, Miyazaki K, Koyama A, Ikeda K, Hukiage M, Kitamura H. Effect of gaiters on muscle pump activity in healthy volunteers. Phlebology 2012. [PMID: 23202138 DOI: 10.1258/phleb.2012.012007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVES Exercise of the leg with external limb compression has been reported to be useful for preventing and reducing leg oedema. The aim of this study was to investigate the effects of leg gaiters on calf muscle pump activity. METHODS Continuous measurements of the interface pressure at the leg during exercise and determination of the femoral venous velocity at the groin during exercise were carried out in healthy volunteers with elastic stockings alone, leg gaiters alone and gaiters over the elastic stockings. RESULTS The greatest pressure difference between muscle contraction and relaxation during exercise was observed when gaiters were applied over the elastic stockings at the calf. Gaiters alone without elastic stockings led to a significantly greater pressure difference between muscle contraction and relaxation during exercise than elastic stockings alone (P < 0.01). A significantly higher value of the peak flow velocity of the femoral vein was observed with the combined use of gaiters and elastic stockings than the single use of elastic stockings. CONCLUSIONS Leg gaiters have a beneficial effect of augmenting venous femoral blood flow during calf muscle pump activity in volunteers with a normal valve function of leg veins.
Collapse
|
43
|
Miyazaki K, Hirai M, Koyama A, Iwata H, Ohashi M, Ota A. Interface pressure is affected by slippage of bandages at thigh. INT ANGIOL 2012; 31:544-549. [PMID: 23222932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
AIM Very little is known about how compression bandages lose interface pressure. We hypothesized that the loss of interface pressure is correlated with the slippage of the bandages, and studied the interface pressure and slippage of three bandages over 8 hours. METHODS Twenty-Seven legs from 27 healthy volunteers were bandaged with short stretch bandages (SS), cohesive short stretch bandages (CS), and long stretch bandages (LS). Pressure sensors were placed above the ankle (B1), below the knee (D), and mid thigh (F). Interface pressures in a sitting position were recorded at the beginning, and 4 and 8 hours later. In 17 legs, the pressure sensor sites were marked, and their heights were measured on standing upright. RESULTS SS and CS lost interface pressure quickly, but LS maintained pressure better than SS and CS at all sites. There was no pressure difference between SS and CS at the lower leg. However, CS maintained pressure better than SS at the mid thigh (44.6% vs. 54.4% pressure loss at 8 hours, respectively. P=0.037). There was a tendency toward less slippage with CS than SS at the mid thigh. In CS and LS, there was a linear correlation between the slippage of bandages and the interface pressure at the mid thigh (P <.01, in both). CONCLUSION The interface pressure may be affected by the slippage of bandages at the thigh, but not at the lower leg. Cohesive short stretch bandages may exert their beneficial impact at the thigh.
Collapse
|
44
|
Hirai M, Iwata H, Miyazaki K, Koyama A, Nakamura H. Development of separated elastic stockings. Phlebology 2012; 28:201-8. [DOI: 10.1258/phleb.2011.011140] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Objectives To investigate the acceptability of newly developed separated elastic stockings, which are divided into two portions at the ankle. Methods The difficulty in putting on and taking off stockings was compared between the original or modified separated stockings with various techniques in order to reduce the shift of the stockings and current non-separated stockings in healthy volunteers and patients with lymphoedema by applying both stockings alternately. In the modified model, the shift during daily activities was measured in healthy volunteers and patients with lymphoedema. Results The two items, ‘easier compared with non-separated stockings’ and ‘much easier’, were chosen at rates of 75% and 81% for putting on and taking off stockings for the original separated stockings and 75% and 75% for the modified separated stockings, respectively. Complaints during daily activities with the modified type to the stockings decreased as compared with the original type. The shift of stockings after an average 11-hour application was 1.6 ± 3.0 SD mm (range: 0–10 mm). Conclusions Modified separated elastic stockings are easier to put on and take off compared with current non-separated stockings, and they can be used safely because of their low-level shift during daily activities.
Collapse
|
45
|
Hirai M, Koyama A, Miyazaki K, Iwata H, Kominami Y. Interface pressure and stiffness in different combinations of compression material. Phlebology 2011; 27:82-9. [DOI: 10.1258/phleb.2011.011010] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Objectives To compare the interface pressure and stiffness between various combinations of compression material. Methods Using a stiffness-determining device, the interface pressure and stiffness were determined in several combinations of five elastic stockings and two elastic bandages. Results In the double stockings system, the interface pressure increased significantly and the highest stiffness was observed in double short-stretch stockings. When short-stretch bandages were applied over either short- or long-stretch stockings, a significant increase in stiffness was observed at any initial pressure compared with the single use of short-stretch stockings. In double bandage systems, when short-stretch bandages were applied over either short- or long-stretch bandages, the stiffness increased significantly. When long-stretch bandages were used over short-stretch bandages, the stiffness decreased significantly. Conclusions The stiffness is changeable according to the combinations of material, such as double stockings, double bandages and the wearing of bandages over stockings. The use of short-stretch bandages as the outside layer produces the highest stiffness at a high initial pressure.
Collapse
|
46
|
Ioroi T, Kakuma T, Sakashita A, Ishibashi Y, Ohtagaki K, Fujiwara Y, Mukohara T, Kume M, Hirai M, Minami H, Nishimura Y. Evaluation of factors that intervention of palliative care team contributes to quality-of-life improvement of Japanese patients with advanced cancer. J Clin Oncol 2011. [DOI: 10.1200/jco.2011.29.15_suppl.e19517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
47
|
Hirai M, Nakajima A, Kawai N, Tanaka E, Igarashi Y, Sakaguchi M, Sameshima GT, Shimizu N. Measurements of the torque moment in various archwire-bracket-ligation combinations. Eur J Orthod 2011; 34:374-80. [DOI: 10.1093/ejo/cjr022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
48
|
Hirai M, Niimi K, Miyazaki K, Iwata H, Sugimoto I, Ishibashi H, Ota T, Kominami Y. Development of a device to determine the stiffness of elastic garments and bandages. Phlebology 2011; 26:285-91. [DOI: 10.1258/phleb.2010.010041] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Objective To evaluate the reliability of a newly developed stiffness-determining device, composed of a leg mannequin and air-pack type analyser, for measuring the interface pressure. Method The correlation of stiffness values obtained employing the Hohenstein method and this new method was investigated using 17 different brands of medical elastic compression stocking. Results A significant correlation in stiffness values using the two methods was obtained ( P < 0.01). When this new method was applied to the bandages, the stiffness was significantly correlated with the initial pressure when assessing both short-stretch and long-stretch bandages. On the comparison of stiffness values between elastic stockings and bandages with the same initial pressure, the short-stretch bandages showed a predominantly higher value than long-stretch bandages and stockings ( P < 0.01). Conclusion The reliability of this new method, which can be easily applied to not only elastic stockings but also elastic bandages, was verified. In clinical practice, the compression pressure should be selected in consideration of the prospective stiffness.
Collapse
|
49
|
Hirai M, Iwata H, Niimi K, Miyazaki K, Koyama A, Komatsubara R. Improvement of a three-dimensional measurement system for the evaluation of foot edema. Skin Res Technol 2011; 18:120-4. [PMID: 21429012 DOI: 10.1111/j.1600-0846.2011.00527.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND/AIMS This study investigated the accuracy and usefulness of a newly improved three-dimensional measurement system for measuring the volume and circumference at the foot as well as at the calf and ankle. METHODS Regarding the newly improved device, halogen light was projected from four directions instead of the conventional two directions. The circumference and volume were measured in the morning and evening with and without elastic stockings in 23 healthy subjects. RESULTS The average circumference at the foot calculated using the 'average method', in which the circumference of the foot was measured in 10 places every 1 mm and the values were averaged, significantly increased in the evening compared with in the morning. When stockings were applied, the significant differences in the circumference or volume between the morning and evening disappeared at all sites of the leg. CONCLUSION The newly improved three-dimensional measurement system incorporating the halogen light from four directions, in which the foot circumference was calculated using an 'average method', was reliable and useful for evaluating edema at the foot as well as at the calf and ankle. The beneficial effect of elastic stockings on edema prevention was observed at all sites of the leg.
Collapse
|
50
|
Hirai M, Saunders DR, Troje NF. Allocation of attention to biological motion: Local motion dominates global shape. J Vis 2011; 11:11.3.4. [DOI: 10.1167/11.3.4] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|