26
|
Wong J, Tsujimoto A, Fischer NG, Baruth AG, Barkmeier WW, Johnson EA, Samuel SM, Takamizawa T, Latta MA, Miyazaki M. Enamel Etching for Universal Adhesives: Examination of Enamel Etching Protocols for Optimization of Bonding Effectiveness. Oper Dent 2019; 45:80-91. [PMID: 31226005 DOI: 10.2341/18-275-l] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate whether different enamel etching methods with reduced etching times would improve the bonding effectiveness of universal adhesives. METHODS AND MATERIALS Three enamel etching methods, phosphoric acid ester monomer (PPM) etching, phosphoric acid (PPA) etching, and polyalkenoic acid (PLA) etching, and three universal adhesives, G-Premio Bond (GP), Prime&Bond elect (PE), and Scotchbond Universal Adhesive (SU), were evaluated. Initial bond strengths and fatigue strengths of universal adhesives to ground enamel and ground enamel etched for less than one, five, 10, and 15 seconds using different etching methods were determined. The bonded fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred with a staircase method. Atomic force micrograph (AFM) observations along with measurements of surface Ra roughness and modified surface area of enamel with different etching protocols were also conducted. RESULTS The bond fatigue durability of universal adhesives to enamel with PPA etching from less than one to 15 seconds and PLA etching for 15 seconds was significantly higher than that to ground enamel. The bond fatigue durability to enamel with PPM etching was not increased compared with ground enamel. The surface Ra roughness and surface area obtained with AFM of enamel increased after PPA and PLA etching, and those values were significantly higher than those of ground enamel. Furthermore, surface Ra roughness and surface area with PPA etching were significantly higher than those with PLA etching. However, surface Ra roughness and surface area of enamel with PPM etching were similar to those of ground enamel regardless of etching time. CONCLUSION PPA etching for less than one to 15 seconds and PLA etching for 15 seconds improve universal adhesive bonding, surface Ra roughness, and surface area of enamel. However, PPM etching is not effective, regardless of etching time, in improving bonds strengths, increasing surface roughness, and increasing surface area.
Collapse
|
27
|
Inui S, Ueda Y, Ono S, Ohira S, Isono M, Nitta Y, Murata S, Miyazaki M, Teshima T. EP-1747 In vivo dosimetry with electronic portal imaging device in VMAT for prostate cancer. Radiother Oncol 2019. [DOI: 10.1016/s0167-8140(19)32167-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
28
|
Moritake N, Takamizawa T, Ishii R, Tsujimoto A, Barkmeier WW, Latta MA, Miyazaki M. Effect of Active Application on Bond Durability of Universal Adhesives. Oper Dent 2019; 44:188-199. [DOI: 10.2341/17-384-l] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The purpose of this study was to determine the effect of different adhesive application methods and etching modes on the dentin bond durability of universal adhesives under thermal cycling (TC). All-Bond Universal (Bisco), Adhese Universal (Ivoclar Vivadent), and Scotchbond Universal (3M ESPE) were used as adhesives. In total, 600 bovine teeth with exposed dentin were divided into 12 groups according to the type of adhesive and subjected to the following bonding procedures: 1) etch-and-rinse mode with active application; 2) etch-and-rinse mode with inactive application; 3) self-etch mode with active application; and 4) self-etch mode with inactive application. Bonded specimens were stored in distilled water at 37°C for 24 hours and then subjected to 5000, 10,000, 30,000, or 50,000 TC between 5°C and 55°C before shear bond strength (SBS) testing, creating a division into a total of five different storage conditions. Baseline specimens were stored in distilled water at 37°C for 24 hours. The SBS test was performed at a cross-head speed of 1.0 mm/min. Three-way analysis of variance revealed that all the factors of application mode, adhesive, and thermal cycle period significantly influenced the SBS values (p<0.001), regardless of the etching mode. In the baseline groups, all of the tested adhesives with active application had higher SBS values than those with inactive application, regardless of etching mode. In the TC groups, significantly lower SBS values were observed at 50,000 TC with inactive application compared to those with active application, regardless of the etching mode. From the scanning electron microscopy observation of demineralized and deproteinized resin/dentin interfaces, dense resin tags longer than 50 μm were observed in the etch-and-rinse with active application group. On the other hand, the resin tags in self-etch mode were sparse, thin, and much shorter than those in etch-and-rinse mode. Comparing the penetration status of the resin tags with active and inactive application in self-etch mode, the resin tag penetration with inactive application was much lower than that with active application. Active application is effective in enhancing the dentin bond durability of universal adhesives. When using universal adhesives with different etching modes, practitioners should select the optimal etching mode and appropriate application method in accordance with the cavity conditions.
Collapse
|
29
|
Nagura Y, Tsujimoto A, Fischer NG, Baruth AG, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. Effect of Reduced Universal Adhesive Application Time on Enamel Bond Fatigue and Surface Morphology. Oper Dent 2019; 44:42-53. [DOI: 10.2341/17-261-l] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
The purpose of this study was to evaluate the effect of reduced application times of universal adhesives on enamel bond fatigue and surface morphology of the treated enamel with constant force atomic force microscopy (AFM).
Methods:
Four universal adhesives—Adhese Universal (AU), Clearfil Universal Bond Quick (CU), G-Premio Bond (GP), and Scotchbond Universal Adhesive (SU)—were evaluated in a laboratory for their ability to adhesively bond resin composite to enamel. Shear bond strengths were initially determined using 15 specimens per test group for each adhesive. Shear fatigue strengths were then determined using 20 specimens per test group for each the adhesives. The fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. AFM observations, surface Ra roughness measurements, and geometric surface area evaluations of enamel surface treated with the adhesive agents were also conducted.
Results:
A strong relationship was found between the initial shear bond strength and shear fatigue strength for enamel surface Ra roughness but not for geometric surface area. The initial shear bond strength and shear fatigue strength of CU and GP were not influenced by different application times, unlike those of AU and SU. While the surface area of enamel treated with the adhesive agents was not significantly influenced by different application times and type of adhesive, surface Ra roughness of the enamel in the AU and SU groups significantly increased with increasing application time, unlike CU and GP.
Conclusions:
The results of this study suggest that universal adhesives, used with reduced application times, have adequate Ra surface roughness to provide sufficient resistance to enamel bond fatigue at application times from <1 second to 20 seconds, while the geometric surface area of adhesive-treated enamel did not show any significant changes at these different application times.
Collapse
|
30
|
Ozawa N, Hase T, Hatta T, Sagara A, Ichikawa K, Miyazaki M, Ando M, Yamada K, Hasegawa Y. Retrospective analysis of risk factor of injection site reaction induced by infusion of cisplatin plus vinorelbine. Ann Oncol 2018. [DOI: 10.1093/annonc/mdy442.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
31
|
Hagiwara D, Sato K, Miyazaki M, Kamada M, Moriwaki N, Nakano T, Shiotsuka S, Tokushige C, Toh H, Kamimura H, Togawa A, Takata T. The impact of earlier intervention by an antimicrobial stewardship team for specific antimicrobials in a single weekly intervention. Int J Infect Dis 2018; 77:34-39. [PMID: 30292892 DOI: 10.1016/j.ijid.2018.09.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 09/26/2018] [Accepted: 09/28/2018] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVE The objective of this study was to evaluate the effects of earlier intervention by an antimicrobial stewardship team (AST) on antimicrobial use, antimicrobial resistance rates, and the clinical outcomes, without changing the weekly intervention schedule. METHODS A retrospective study was conducted at Fukuoka University Hospital between April 2013 and March 2016. The effects were compared among three study periods (SP): SP1 (patients receiving anti-methicillin-resistant Staphylococcus aureus agents and carbapenems for ≥14 days), SP2 (patients receiving specific antimicrobials for ≥14 days), and SP3 (patients receiving specific antimicrobials regardless of the duration of treatment). RESULTS The timing of AST intervention was shortened from an average of 15.5days after administration in SP1 to 4.2 days in SP3. The antimicrobial use density (AUD) of carbapenems and piperacillin-tazobactam decreased significantly (SP2 vs. SP3, p<0.05), and the costs of specific antimicrobials decreased (SP1, US$ 1080000; SP2, US$ 944000; SP3, US$ 763000). The rates of carbapenem resistance among Pseudomonas aeruginosa isolates showed a significant reduction from 16.2% in SP2 to 8.7% in SP3 (p<0.05). The mortality rate and length of stay did not change during the study period. CONCLUSIONS Earlier intervention by an AST could contribute to the proper use of antimicrobials without adversely affecting patient outcomes.
Collapse
|
32
|
Aguzzi J, Fanelli E, Ciuffardi T, Schirone A, De Leo FC, Doya C, Kawato M, Miyazaki M, Furushima Y, Costa C, Fujiwara Y. Faunal activity rhythms influencing early community succession of an implanted whale carcass offshore Sagami Bay, Japan. Sci Rep 2018; 8:11163. [PMID: 30042515 PMCID: PMC6057991 DOI: 10.1038/s41598-018-29431-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 07/03/2018] [Indexed: 11/20/2022] Open
Abstract
Benthic community succession patterns at whale falls have been previously established by means of punctual submersible and ROV observations. The contribution of faunal activity rhythms in response to internal tides and photoperiod cues to that community succession dynamism has never been evaluated. Here, we present results from a high-frequency monitoring experiment of an implanted sperm whale carcass in the continental slope (500 m depth) offshore Sagami Bay, Japan. The benthic community succession was monitored at a high frequency in a prolonged fashion (i.e. 2-h intervals for 2.5 months) with a seafloor lander equipped with a time-lapse video camera and an acoustic Doppler profiler to concomitantly study current flow dynamics. We reported here for the first time, to the best of our knowledge, the occurrence of strong 24-h day-night driven behavioral rhythms of the most abundant species (Simenchelys parasitica; Macrocheira kaempferi, and Pterothrissus gissu). Those rhythms were detected in detriment of tidally-controlled ones. Evidence of a diel temporal niche portioning between scavengers and predators avoiding co-occurrence at the carcass, is also provided. The high-frequency photographic and oceanographic data acquisition also helped to precisely discriminate the transition timing between the successional stages previously described for whale falls’ attendant communities.
Collapse
|
33
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. Influence of Thermal Stress on Simulated Localized and Generalized Wear of Nanofilled Resin Composites. Oper Dent 2018; 43:380-390. [DOI: 10.2341/16-206-l] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
This study investigated the influence of thermal stress on the simulated localized and generalized wear of nanofilled resin composites.
Methods:
Six nanofilled resin composites were evaluated and then subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulation device after 24 hours of water storage (24-hour group) and 24 hours of water storage and 10,000 thermal cycles (TC group). Simulated localized wear was generated using a stainless-steel ball bearing, and simulated generalized wear was generated using a flat-ended stainless-steel cylinder. Wear testing was accomplished in a water slurry of polymethyl methacrylate beads. Simulated localized and generalized wear was determined using a noncontact profilometer (Proscan 2100) in conjunction with Proscan and AnSur 3D software.
Results:
Wear was significantly different (p<0.05) among the resin composites for both simulated localized and generalized wear of either the 24-hour group or the TC group. The simulated localized wear of the TC group was significantly greater than that of the 24-hour group; however, the simulated generalized wear of most of the resin composites of the TC group was not significantly different from that of the 24-hour group.
Conclusion:
The simulated localized and generalized wear of nanofilled resin composites is material dependent. The simulated localized wear of nanofilled resin composites appears to be influenced by thermal stress, whereas this effect is not as apparent in simulated generalized wear testing.
Collapse
|
34
|
Miyazaki M, Asai Y, Iwakura M, Hara M. 0442 Safety and Efficacy of Suvorexant in a Real World Setting: Results from the Drug Use-results Survey in Japan. Sleep 2018. [DOI: 10.1093/sleep/zsy061.441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
35
|
Suda S, Takamizawa T, Takahashi F, Tsujimoto A, Akiba S, Nagura Y, Kurokawa H, Miyazaki M. Application of the Self- Assembling Peptide P11-4 for Prevention of Acidic Erosion. Oper Dent 2018. [PMID: 29513639 DOI: 10.2341/17-175-l] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to use ultrasonography to evaluate the effect of the self-assembling peptide P11-4 on acid erosion prevention. Curodont Repair (CR), which includes peptide P11-4, was used. Rectangular prisms of bovine enamel (4×1×1 mm) were immersed in pure orange juice for a period of 5 minutes six times per day for 28 days. These samples were divided into four groups of six specimens each and treated differently for an additional period of 28 days: 1) baseline group specimens were stored in artificial saliva; 2) CR group specimens were exposed to curodont without acid challenge; 3) NCRA (no curodont+acid challenge) specimens were treated with orange juice without curodont exposure; and 4) CRA (CR+acid challenge) specimens were treated with curodont before treatment with orange juice. The propagation time of longitudinal ultrasonic velocity (UV) was measured. Ultrastructural observation of each tested enamel surface was carried out using field-emission scanning electron microscopy (SEM). The UV data were analyzed using two-way analysis of variance with time and treatment as confounding factors. Post hoc pairwise tests among groups were performed using the Tukey honestly significant difference test. The average UV in intact bovine enamel for the baseline group ranged from 4,483 to 4,549 m/s and did not vary significantly within the test period. The average ultrasonic velocity (UV) in all samples decreased after the initial erosion. The UV in NCRA decreased further over time. Increased UVs were found for CR and CRA. For CR and CRA, there was no significant difference in UV at the end of the experiment from the initial value before erosion. In the results of SEM observation, the CR and CRA groups had similar morphologic features in that etching patterns were not clearly due to precipitation between the enamel rods. From the results of this in vitro study, it might be concluded that applying enamel matrix derivatives and self-assembling peptides on erosive lesions can improve remineralization.
Collapse
|
36
|
Mochizuki Y, Kubota T, Hata Y, Miyazaki M, Suyama Y, Enaida H, Ueno A, Ishibashi T. Surgical Results of Combined Pars Plana Vitrectomy, Phacoemulsification, and Intraocular Lens Implantation for various Vitreoretinal Diseases. Eur J Ophthalmol 2018; 16:279-86. [PMID: 16703547 DOI: 10.1177/112067210601600214] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the results and complications of combined pars plana vitrectomy (PPV), phacoemulsification and aspiration (PEA), and intraocular lens (IOL) implantation. METHODS A total of 117 eyes from 114 patients who had undergone PPV combined with PEA and IOL implantation were retrospectively analyzed. Combined surgery was performed for a wide variety of vitreoretinal diseases. Intraoperative and postoperative complications were also reviewed. RESULTS The postoperative BCVA improved by 2 lines or more in 85 eyes (72.6%). Intraoperative complications consisted of retinal tears in 14 eyes (12.0%) and posterior capsular rupture in 2 eyes (1.7%). Iatrogenic retinal tears occurred more frequently in eyes with a macular hole than in eyes with any other disease (p=0.005, chi-square test). Postoperative complications consisted of posterior capsule opacification (PCO) (21 eyes), transient IOP elevation (29 eyes), vitreous hemorrhage (6 eyes), anterior chamber fibrin exudation (11 eyes), posterior iris synechia (8 eyes), neovascular glaucoma (1 eye), and recurrent retinal detachment (RD) (2 eyes). Fibrin exudation occurred more frequently in eyes with proliferative diabetic retinopathy (PDR) and RD than in eyes with any other disease (p=0.03, chi-square test). PCO occurred more frequently in eyes with PDR than in eyes with any other disease (p=0.03, chi-square test). CONCLUSIONS The present study suggests that a high success rate can be achieved when recently improved PPV techniques are combined wi th PEA and IOL implantation. The complications that were observed following this combined treatment varied with respect to the vitreoretinal disease present prior to surgery.
Collapse
|
37
|
Amao Y, Fujimura M, Miyazaki M, Tadokoro A, Nakamura M, Shuto N. A visible-light driven electrochemical biofuel cell with the function of CO2conversion to formic acid: coupled thylakoid from microalgae and biocatalyst immobilized electrodes. NEW J CHEM 2018. [DOI: 10.1039/c8nj01118d] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A new visible-light driven electrochemical biofuel cell consisting of the thylakoid membrane of microalgae immobilized on a TiO2layer electrode as a photoanode, a formate dehydrogenase/viologen co-immobilized electrode as a cathode, and a CO2-saturated buffer solution as the redox electrolyte, was developed.
Collapse
|
38
|
Miyazaki M, Asai Y, Iwakura M, Hara M. Safety and efficacy of suvorexant in a real world setting: interim results from the drug use-results survey in Japan. Sleep Med 2017. [DOI: 10.1016/j.sleep.2017.11.669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
39
|
Kanaguchi Arita A, Yonemitsu I, Ikeda Y, Miyazaki M, Ono T. Low-intensity pulsed ultrasound stimulation for mandibular condyle osteoarthritis lesions in rats. Oral Dis 2017; 24:600-610. [DOI: 10.1111/odi.12798] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 09/26/2017] [Accepted: 10/18/2017] [Indexed: 11/30/2022]
|
40
|
Shibasaki S, Takamizawa T, Nojiri K, Imai A, Tsujimoto A, Endo H, Suzuki S, Suda S, Barkmeier WW, Latta MA, Miyazaki M. Polymerization Behavior and Mechanical Properties of High-Viscosity Bulk Fill and Low Shrinkage Resin Composites. Oper Dent 2017; 42:E177-E187. [DOI: 10.2341/16-385-l] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The present study determined the mechanical properties and volumetric polymerization shrinkage of different categories of resin composite. Three high viscosity bulk fill resin composites were tested: Tetric EvoCeram Bulk Fill (TB, Ivoclar Vivadent), Filtek Bulk Fill posterior restorative (FB, 3M ESPE), and Sonic Fill (SF, Kerr Corp). Two low-shrinkage resin composites, Kalore (KL, GC Corp) and Filtek LS Posterior (LS, 3M ESPE), were used. Three conventional resin composites, Herculite Ultra (HU, Kerr Corp), Estelite ∑ Quick (EQ, Tokuyama Dental), and Filtek Supreme Ultra (SU, 3M ESPE), were used as comparison materials. Following ISO Specification 4049, six specimens for each resin composite were used to determine flexural strength, elastic modulus, and resilience. Volumetric polymerization shrinkage was determined using a water-filled dilatometer. Data were evaluated using analysis of variance followed by Tukey's honestly significant difference test (α=0.05). The flexural strength of the resin composites ranged from 115.4 to 148.1 MPa, the elastic modulus ranged from 5.6 to 13.4 GPa, and the resilience ranged from 0.70 to 1.0 MJ/m3. There were significant differences in flexural properties between the materials but no clear outliers. Volumetric changes as a function of time over a duration of 180 seconds depended on the type of resin composite. However, for all the resin composites, apart from LS, volumetric shrinkage began soon after the start of light irradiation, and a rapid decrease in volume during light irradiation followed by a slower decrease was observed. The low shrinkage resin composites KL and LS showed significantly lower volumetric shrinkage than the other tested materials at the measuring point of 180 seconds. In contrast, the three bulk fill resin composites showed higher volumetric change than the other resin composites. The findings from this study provide clinicians with valuable information regarding the mechanical properties and polymerization kinetics of these categories of current resin composite.
Collapse
|
41
|
Ouchi H, Tsujimoto A, Nojiri K, Hirai K, Takamizawa T, Barkmeier WW, Latta MA, Miyazaki M. Effect of Oxygen Inhibition Layer of Universal Adhesives on Enamel Bond Fatigue Durability and Interfacial Characteristics With Different Etching Modes. Oper Dent 2017; 42:636-645. [PMID: 28976848 DOI: 10.2341/16-255-l] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effect of the oxygen inhibition layer of universal adhesive on enamel bond fatigue durability and interfacial characteristics with different etching modes. METHODS The three universal adhesives used were Scotchbond Universal Adhesive (3M ESPE, St Paul, MN, USA), Adhese Universal (Ivoclar Vivadent, Schaan, Lichtenstein), and G-Premio Bond (GC, Tokyo, Japan). The initial shear bond strength and shear fatigue strength to enamel was determined in the presence and absence of the oxygen inhibition layer, with and without phosphoric acid pre-etching. The water contact angle was also measured in all groups using the sessile drop method. RESULTS The enamel bonding specimens with an oxygen inhibition layer showed significantly higher (p<0.05) initial shear bond strengths and shear fatigue strengths than those without, regardless of the adhesive type and etching mode. Moreover, the water contact angles on the specimens with an oxygen inhibition layer were significantly lower (p<0.05) than on those without, regardless of etching mode. CONCLUSION The results of this study suggest that the oxygen inhibition layer of universal adhesives significantly increases the enamel bond fatigue durability and greatly changes interfacial characteristics, suggesting that the bond fatigue durability and interfacial characteristics of these adhesives strongly rely on its presence.
Collapse
|
42
|
Mukai Y, Miyazaki M, Mukai T, Tasaki A, Yuji T, Murata M. The pharmacokinetics of patients with Parkinson’s disease receiving levodopa-carbidopa intestinal gel infusion therapy. J Neurol Sci 2017. [DOI: 10.1016/j.jns.2017.08.1652] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
43
|
Miyazaki M, Ueda Y, Oohira S, Tsujii K, Isono M, Masaoka A, Inui S, Teshima T. Planning Study for Esophageal Cancer: A Dosimetric Comparison of Conformal Radiation Therapy, VMAT, and Hybrid-VMAT. Int J Radiat Oncol Biol Phys 2017. [DOI: 10.1016/j.ijrobp.2017.06.2284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Miyazaki T, Okada K, Miyazaki M. Short communication: Neonatal calves coagulate first-milking colostrum and produce a large curd for efficient absorption of immunoglobulins after first ingestion. J Dairy Sci 2017; 100:7262-7270. [DOI: 10.3168/jds.2017-12808] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Accepted: 05/10/2017] [Indexed: 01/29/2023]
|
45
|
Nuki Y, Umeno J, Washio E, Maehata Y, Hirano A, Miyazaki M, Kobayashi H, Kitazono T, Matsumoto T, Esaki M. The influence of CYP2C19 polymorphisms on exacerbating effect of rabeprazole in celecoxib-induced small bowel injury. Aliment Pharmacol Ther 2017; 46:331-336. [PMID: 28481007 DOI: 10.1111/apt.14134] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2016] [Revised: 01/20/2017] [Accepted: 04/14/2017] [Indexed: 12/12/2022]
Abstract
BACKGROUND Simultaneous use of proton pump inhibitors (PPIs) has been shown to increase the risk of nonsteroidal anti-inflammatory drug (NSAID)-induced small bowel injury. AIM To investigate whether polymorphisms of the cytochrome P450 2C19 gene (CYP2C19), encoding a key metabolising enzyme for PPIs, are associated with small bowel injury induced by celecoxib in combination with the PPI rabeprazole. METHODS Study participants included 55 healthy Japanese volunteers, who participated in the PPI-NSAID Kyushu University Study using video capsule endoscopy. For 2 weeks, 26 subjects were treated with celecoxib plus rabeprazole (rabeprazole group), and 29 subjects received celecoxib plus placebo (placebo group). All subjects were genotyped for CYP2C19 using real-time fluorescent polymerase chain reaction. Subjects were sub-classified as poor metabolizers or extensive metabolizers. The incidence and number of small bowel injuries were compared between poor metabolizers and extensive metabolizers in each group. RESULTS In the rabeprazole group, the incidence of small bowel injuries was significantly higher in poor metabolizers than in extensive metabolizers (85.7% vs 31.6%, P=.026). The number of mucosal injuries in the rabeprazole group was also significantly higher in poor metabolizers compared with extensive metabolizers (median [range] 3 [0-31] vs 0 [0-7], P=.01). In addition, we found a significant interaction between CYP2C19 genotype and concomitant use of rabeprazole in subjects at risk for celecoxib-induced small bowel injury. CONCLUSIONS The CYP2C19 genotype might be associated with the risk of small bowel injury when celecoxib is combined with rabeprazole.
Collapse
|
46
|
Ura C, Okamura T, Yamazaki S, Ishiguro T, Miyazaki M, Ibe M, Kubota A, Kawamuro Y. RICE-FARMING CARE FOR PEOPLE WITH DEMENTIA; A NOVEL WAY OF SOCIAL PARTICIPATION FOR THE ELDERLY. Innov Aging 2017. [DOI: 10.1093/geroni/igx004.647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
47
|
Shibasaki S, Takamizawa T, Suzuki T, Nojiri K, Tsujimoto A, Barkmeier WW, Latta MA, Miyazaki M. Influence of Different Curing Modes on Polymerization Behavior and Mechanical Properties of Dual-Cured Provisional Resins. Oper Dent 2017; 42:526-536. [PMID: 28605612 DOI: 10.2341/16-335-l] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study determined the influence of curing mode on polymerization behavior and mechanical properties of dual-cured provisional resins. Three dual-cured bisacryl-based provisional resins were used: Tempsmart (TS; GC Corp), Luxatemp Automix Solar (LX; DMG Chemisch Pharmazeutishe Fabrik GmbH), and Integrity Multi·Cure (IG; Dentsply Caulk). A self-cured bisacryl-based provisional resin, Protemp Plus (PP; 3M ESPE) and a conventional poly(methyl methacrylate) (PMMA) provisional resin, Unifast III (UF; GC Corp) were used as controls. The inorganic filler content and coefficients of linear thermal expansion of the test materials were measured. Six specimens of each material were used to determine the flexural strength, elastic modulus, and resilience. The changes in ultrasound velocity during polymerization were measured. The average inorganic filler contents of the provisional resins, apart from UF, ranged from 24.4 to 39.3 wt%. The highest inorganic filler content was determined for LX, whereas TS showed the lowest value among the tested materials. The average coefficients of thermal expansion of the tested provisional resins ranged from 77.3 to 107.7 (×10-6/°C). TS and IG showed significantly lower thermal expansions than the other tested provisional resins. The mean flexural strengths of the provisional resins ranged from 70.4 to 122.6 MPa, the mean elastic moduli ranged from 1.8 to 3.7 GPa, and the mean resilience of the provisional resins ranged from 1.1 to 2.3 MJ/mm3, respectively. Dual-cured provisional resins showed significantly higher flexural strengths than the PMMA resin. However, in all cases, the light-curing mode showed significantly higher flexural strengths than the self-curing mode. In the initial polymerization phase, dual-cured resins in the light-curing mode showed a rapid increase in the speed of sound (V) during light irradiation, followed by a slower increase. Conversely, the dual-cured resins in the self-curing mode showed a slower initial increase, followed by a rapid increase. Although no significant difference in V was observed between 10 and 15 minutes in the light-curing mode of all tested dual-cured resins, a significantly higher V value was obtained at 15 minutes than at 10 minutes in the self-curing modes for LX and IG. Regardless of the curing mode, tested dual-cured provisional resins showed superior mechanical properties than the conventional PMMA provisional resin. However, dual-cured provisional resin flexural properties and polymerization behavior were affected by the curing mode. This study indicated that the light-curing mode might be recommended for all dual-cured provisional resins because of the enhancement of their mechanical properties and reduction of chair time.
Collapse
|
48
|
Miyazaki T, Okada K, Yamashita T, Miyazaki M. Two-dimensional gas chromatography time-of-flight mass spectrometry-based serum metabolic fingerprints of neonatal calves before and after first colostrum ingestion. J Dairy Sci 2017; 100:4354-4364. [DOI: 10.3168/jds.2017-12557] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Accepted: 01/29/2017] [Indexed: 12/26/2022]
|
49
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Wilwerding TM, Latta MA, Miyazaki M. Interfacial Characteristics and Bond Durability of Universal Adhesive to Various Substrates. Oper Dent 2017; 42:E59-E70. [DOI: 10.2341/15-353-l] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective: This study investigated the interfacial characteristics and bond durability of universal adhesives to various substrates.
Methods and Materials: Two universal adhesives were used: 1) Scotchbond Universal and 2) G-Premio Bond. The substrates used were bovine enamel and dentin with or without phosphoric acid etching, resin composite, lithium disilicate and leucite-reinforced glass ceramics, zirconia, and metal alloys. The surface free energy and the parameters of various substrates and of substrates treated by adhesive after light irradiation were determined by measuring the contact angles of three test liquids. Resin composite was bonded to the various substrates to determine shear bond strength after 24 hours water storage and 10,000 thermal cycles. A one-way analysis of variance (ANOVA) and the Tukey post hoc test were used for the surface free energy data, and a two-way ANOVA and the Tukey post hoc test were used for analysis of shear bond strength data (α=0.05).
Results: The interfacial characteristics of the various substrates show significant differences depending on the type of substrate, but the interfacial characteristics of substrate treated by adhesive after light irradiation did not show any significant differences regardless of the substrate used. The bond durability of two universal adhesives to various substrates differs depending on the type of substrate and the adhesive.
Conclusions: The results of this study suggest that universal adhesives modify the interfacial characteristics of a wide range of substrates and create a consistent surface, but the bond durability of universal adhesive to various substrates differs depending on the type of substrate and the adhesive.
Collapse
|
50
|
Kanayama N, Kierkels R, Steenbakkers R, Van der Schaaf A, Miyazaki M, Fujii T, Nishiyama K, Langendijk J, Teshima T. PO-064: Normal tissue complication probability model for tube feeding dependence 6 months after radiotherapy. Radiother Oncol 2017. [DOI: 10.1016/s0167-8140(17)30198-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|