26
|
Mohammadi A, Hassanzadeh M, Gharib M. Shielding calculation and criticality safety analysis of spent fuel transportation cask in research reactors. Appl Radiat Isot 2016; 108:129-132. [PMID: 26720262 DOI: 10.1016/j.apradiso.2015.12.045] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Revised: 12/14/2015] [Accepted: 12/16/2015] [Indexed: 10/22/2022]
Abstract
In this study, shielding calculation and criticality safety analysis were carried out for general material testing reactor (MTR) research reactors interim storage and relevant transportation cask. During these processes, three major terms were considered: source term, shielding, and criticality calculations. The Monte Carlo transport code MCNP5 was used for shielding calculation and criticality safety analysis and ORIGEN2.1 code for source term calculation. According to the results obtained, a cylindrical cask with body, top, and bottom thicknesses of 18, 13, and 13 cm, respectively, was accepted as the dual-purpose cask. Furthermore, it is shown that the total dose rates are below the normal transport criteria that meet the standards specified.
Collapse
|
27
|
Amini M, Fadaei AH, Gharib M. Analyzing the effect of geometric factors on designing neutron radiography system. Appl Radiat Isot 2015; 105:249-256. [PMID: 26343340 DOI: 10.1016/j.apradiso.2015.08.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2015] [Revised: 08/15/2015] [Accepted: 08/19/2015] [Indexed: 11/26/2022]
Abstract
Neutron radiography is one of the main applications of research reactors. It is a powerful tool to conduct nondestructive testing of materials. The parameters that affect the quality of a radiographic image must be considered during the design of a neutron radiography system. Hence, this study aims to investigate the effect of geometric factors on the quality of the neutron radiography system. The results show that the performance of the mentioned system can be increased by regulating the geometric factors.
Collapse
|
28
|
Petrasek D, Pahlevan NM, Tavallali P, Rinderknecht DG, Gharib M. Intrinsic Frequency and the Single Wave Biopsy: Implications for Insulin Resistance. J Diabetes Sci Technol 2015; 9:1246-52. [PMID: 26183600 PMCID: PMC4667296 DOI: 10.1177/1932296815588108] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Insulin resistance is the hallmark of classical type II diabetes. In addition, insulin resistance plays a central role in metabolic syndrome, which astonishingly affects 1 out of 3 adults in North America. The insulin resistance state can precede the manifestation of diabetes and hypertension by years. Insulin resistance is correlated with a low-grade inflammatory condition, thought to be induced by obesity as well as other conditions. Currently, the methods to measure and monitor insulin resistance, such as the homeostatic model assessment and the euglycemic insulin clamp, can be impractical, expensive, and invasive. Abundant evidence exists that relates increased pulse pressure, pulse wave velocity (PWV), and vascular dysfunction with insulin resistance. We introduce a potential method of assessing insulin resistance that relies on a novel signal-processing algorithm, the intrinsic frequency method (IFM). The method requires a single pulse pressure wave, thus the term " wave biopsy."
Collapse
|
29
|
Pedrizzetti G, Vlachos PP, Little WC, Sotiropoulos F, Gharib M, Kheradvar A. Comments on Defining the Contribution of Diastolic Vortex Ring to Left Ventricular Filling. J Am Coll Cardiol 2015; 65:2573-4. [PMID: 26065998 DOI: 10.1016/j.jacc.2014.12.076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Accepted: 12/16/2014] [Indexed: 10/23/2022]
|
30
|
Pahlevan NM, Tavallali P, Rinderknecht DG, Petrasek D, Matthews RV, Hou TY, Gharib M. Intrinsic frequency for a systems approach to haemodynamic waveform analysis with clinical applications. J R Soc Interface 2015; 11:20140617. [PMID: 25008087 DOI: 10.1098/rsif.2014.0617] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The reductionist approach has dominated the fields of biology and medicine for nearly a century. Here, we present a systems science approach to the analysis of physiological waveforms in the context of a specific case, cardiovascular physiology. Our goal in this study is to introduce a methodology that allows for novel insight into cardiovascular physiology and to show proof of concept for a new index for the evaluation of the cardiovascular system through pressure wave analysis. This methodology uses a modified version of sparse time-frequency representation (STFR) to extract two dominant frequencies we refer to as intrinsic frequencies (IFs; ω1 and ω2). The IFs are the dominant frequencies of the instantaneous frequency of the coupled heart + aorta system before the closure of the aortic valve and the decoupled aorta after valve closure. In this study, we extract the IFs from a series of aortic pressure waves obtained from both clinical data and a computational model. Our results demonstrate that at the heart rate at which the left ventricular pulsatile workload is minimized the two IFs are equal (ω1 = ω2). Extracted IFs from clinical data indicate that at young ages the total frequency variation (Δω = ω1 - ω2) is close to zero and that Δω increases with age or disease (e.g. heart failure and hypertension). While the focus of this paper is the cardiovascular system, this approach can easily be extended to other physiological systems or any biological signal.
Collapse
|
31
|
Pahlevan NM, Petrasek D, Rinderknecht DG, Tavallali P, Gharib M. Abstract 355: Calculating Pulse Wave Velocity from a Single Pressure Waveform Using the Intrinsic Frequency Method. Hypertension 2014. [DOI: 10.1161/hyp.64.suppl_1.355] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
INTRODUCTION:
Increased aortic stiffness is correlated with many clinically adverse cardiovascular outcomes. The “gold standard” quantitative index for arterial stiffness is the pulse wave velocity (PWV). We have developed a new method called the
Intrinsic Frequency
(
IF
), which views the arterial pressure waveform as a piecewise combination of two coupled systems, the heart and arterial system which are decoupled upon closure of the aortic valve. Each of these dynamical systems has an inherent frequency of operation (ω
1
and ω
2
) which gives information about LV function (ω
1
) as well as arterial dynamics (ω
2
).
METHODS:
IF
methodology is based on Sparse Time-Frequency Representation method. It uses an effective L
2
-minimization to extract the second intrinsic frequency (ω
2
) from an aortic pressure waveform. To examine the clinical relevance of this method,
IF
was applied to aortic pressure waveforms taken from published works. These aortic waveforms were selected from a healthy population free of any cardiovascular diseases (CVD).
RESULTS:
Our results show that ω
2
represents information about the arterial system and that these measurements are highly correlated with PWV (
r=0.9
).
CONCLUSION:
These results show ω
2
can potentially be used to evaluate aortic rigidity and calculate aortic PWV from one pressure waveform. Increased aortic rigidity is a common feature in normal aging and is accelerated in many CVDs including diabetes. One unique advantage of the method is that only a single measurement of the pressure waveform is required to extract the result. Therefore, ω
2
may be employed as a clinically effective noninvasive assessment of cardiovascular health.
Collapse
|
32
|
Aria AI, Gharib M. Physicochemical characteristics and droplet impact dynamics of superhydrophobic carbon nanotube arrays. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:6780-90. [PMID: 24866696 DOI: 10.1021/la501360t] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The physicochemical and droplet impact dynamics of superhydrophobic carbon nanotube arrays are investigated. These superhydrophobic arrays are fabricated simply by exposing the as-grown carbon nanotube arrays to a vacuum annealing treatment at a moderate temperature. This treatment, which allows a significant removal of oxygen adsorbates, leads to a dramatic change in wettability of the arrays, from mildly hydrophobic to superhydrophobic. Such change in wettability is also accompanied by a substantial change in surface charge and electrochemical properties. Here, the droplet impact dynamics are characterized in terms of critical Weber number, coefficient of restitution, spreading factor, and contact time. Based on these characteristics, it is found that superhydrophobic carbon nanotube arrays are among the best water-repellent surfaces ever reported. The results presented herein may pave a way for the utilization of superhydrophobic carbon nanotube arrays in numerous industrial and practical applications, including inkjet printing, direct injection engines, steam turbines, and microelectronic fabrication.
Collapse
|
33
|
Pryzhkova MV, Aria I, Cheng Q, Harris GM, Zan X, Gharib M, Jabbarzadeh E. Carbon nanotube-based substrates for modulation of human pluripotent stem cell fate. Biomaterials 2014; 35:5098-109. [PMID: 24690530 PMCID: PMC4943838 DOI: 10.1016/j.biomaterials.2014.03.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Accepted: 03/07/2014] [Indexed: 11/18/2022]
Abstract
We investigated the biological response of human pluripotent stem cells (hPSCs) cultured on a carbon nanotube (CNT) array-based substrate with the long term goal to direct hPSC germ layer specification for a wide variety of tissue engineering applications. CNT arrays were fabricated using a chemical vapor deposition system allowing for control over surface roughness and mechanical stiffness. Our results demonstrated that hPSCs readily attach to hydrophilized and extracellular matrix coated CNT arrays. hPSCs cultured as colonies in conditions supporting self-renewal demonstrated the morphology and marker expression of undifferentiated hPSCs. Conditions inducing spontaneous differentiation lead to hPSC commitment to all three embryonic germ layers as assessed by immunostaining and RT-PCR analysis. Strikingly, the physical characteristics of CNT arrays favored mesodermal specification of hPSCs. This is contradictory to the behavior of hPSCs on traditional tissue culture plastic which promotes the development of ectoderm. Altogether, these results demonstrate the potential of CNT arrays to be used in the generation of new platforms that allow for precise control of hPSC differentiation by tuning the characteristics of their physical microenvironment.
Collapse
|
34
|
Pahlevan NM, Gharib M. A bio-inspired approach for the reduction of left ventricular workload. PLoS One 2014; 9:e87122. [PMID: 24475239 PMCID: PMC3901771 DOI: 10.1371/journal.pone.0087122] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2013] [Accepted: 12/19/2013] [Indexed: 01/09/2023] Open
Abstract
Previous studies have demonstrated the existence of optimization criteria in the design and development of mammalians cardiovascular systems. Similarities in mammalian arterial wave reflection suggest there are certain design criteria for the optimization of arterial wave dynamics. Inspired by these natural optimization criteria, we investigated the feasibility of optimizing the aortic waves by modifying wave reflection sites. A hydraulic model that has physical and dynamical properties similar to a human aorta and left ventricle was used for a series of in-vitro experiments. The results indicate that placing an artificial reflection site (a ring) at a specific location along the aorta may create a constructive wave dynamic that could reduce LV pulsatile workload. This simple bio-inspired approach may have important implications for the future of treatment strategies for diseased aorta.
Collapse
|
35
|
Pahlevan NM, Gharib M. Pathological wave dynamics: a postulate for sudden cardiac death in athletes. Med Hypotheses 2013; 82:64-70. [PMID: 24284063 DOI: 10.1016/j.mehy.2013.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2012] [Revised: 10/10/2013] [Accepted: 11/06/2013] [Indexed: 01/09/2023]
Abstract
Sudden death (SD) in young athletes is a shocking and disturbing event with significant societal impact. Previous studies have demonstrated that sudden cardiac death (SCD) is the leading medical cause of SD in athletes. Various structural and pathological cardiovascular abnormalities have identified as the underlying causes of SCD in young athletes. However, there have been reported cases of SCD in athletes with no structural or pathological cardiovascular disorders. Our proposed hypothesis in this article is that abnormalities in aortic wave dynamics and coronary wave dynamics may be responsible for SCD in these athletes. These abnormal waves-pathological waves-can act as a trigger toward cardiac death in the presence of cardiovascular diseases. These waves may initiate SCD in the absence of apparent cardiovascular abnormalities. In summary, when the aortic and coronary wave dynamics are abnormal, the myocardial oxygen demand can exceed the oxygen delivery during exercise, hence creating acute ischemia which leads to death. It is explained in this article how increased oxygen demand may be the result of pathological aortic waves while reduced oxygen delivery is mainly due to pathological coronary waves. Additionally, our pathological wave hypothesis is able to provide a plausible explanation for Commotio Cordis.
Collapse
|
36
|
Pahlevan NM, Gharib M. In-vitro investigation of a potential wave pumping effect in human aorta. J Biomech 2013; 46:2122-9. [PMID: 23915578 DOI: 10.1016/j.jbiomech.2013.07.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Revised: 06/29/2013] [Accepted: 07/04/2013] [Indexed: 11/24/2022]
Abstract
An impedance pump - also known as Liebau pump - is a simple valveless pump that operates based on the principles of wave propagation and reflection. It has been shown in embryonic zebrafish that a similar mechanism is responsible for the pumping action in the embryonic heart during the early stages before valve formation. Recent studies suggest that the cardiovascular system is designed to take advantage of wave propagation and reflection phenomena in the arterial network. In this study we report the results of an in-vitro study that examines the hypothesis that the adult human aorta acts as a passive pump based on Liebau effect. A hydraulic model with different compliant models of an artificial aorta was used for a series of in-vitro experiments. Our result indicates that wave propagation and reflection can result in a pumping mechanism in a compliant aorta.
Collapse
|
37
|
Lyon BJ, Aria AI, Gharib M. Feasibility Study of Carbon Nanotube Microneedles for Rapid Transdermal Drug Delivery. ACTA ACUST UNITED AC 2013. [DOI: 10.1557/opl.2013.803] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
ABSTRACTWe introduce a new approach for fabricating hollow microneedles using vertically-aligned carbon nanotubes (VA-CNTs) for rapid transdermal drug delivery. Here, we discuss the fabrication of the microneedles emphasizing the overall simplicity and flexibility of the method to allow for potential industrial application. By capitalizing on the nanoporosity of the CNT bundles, uncured polymer can be wicked into the needles ultimately creating a high strength composite of aligned nanotubes and polymer. Flow through the microneedles as well as in vitro penetration of the microneedles into swine skin is demonstrated. Furthermore, we present a trade study comparing the difficulty and complexity of the fabrication process of our CNT-polymer microneedles with other standard microneedle fabrication approaches.
Collapse
|
38
|
Jamalipour M, Gharib M, Sayareh R, Khoshahval F. PWR power distribution flattening using Quantum Particle Swarm intelligence. ANN NUCL ENERGY 2013. [DOI: 10.1016/j.anucene.2013.01.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
39
|
Aria AI, Gharib M. Dry oxidation and vacuum annealing treatments for tuning the wetting properties of carbon nanotube arrays. J Vis Exp 2013. [PMID: 23629482 DOI: 10.3791/50378] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
In this article, we describe a simple method to reversibly tune the wetting properties of vertically aligned carbon nanotube (CNT) arrays. Here, CNT arrays are defined as densely packed multi-walled carbon nanotubes oriented perpendicular to the growth substrate as a result of a growth process by the standard thermal chemical vapor deposition (CVD) technique.(1,2) These CNT arrays are then exposed to vacuum annealing treatment to make them more hydrophobic or to dry oxidation treatment to render them more hydrophilic. The hydrophobic CNT arrays can be turned hydrophilic by exposing them to dry oxidation treatment, while the hydrophilic CNT arrays can be turned hydrophobic by exposing them to vacuum annealing treatment. Using a combination of both treatments, CNT arrays can be repeatedly switched between hydrophilic and hydrophobic.(2) Therefore, such combination show a very high potential in many industrial and consumer applications, including drug delivery system and high power density supercapacitors.(3-5) The key to vary the wettability of CNT arrays is to control the surface concentration of oxygen adsorbates. Basically oxygen adsorbates can be introduced by exposing the CNT arrays to any oxidation treatment. Here we use dry oxidation treatments, such as oxygen plasma and UV/ozone, to functionalize the surface of CNT with oxygenated functional groups. These oxygenated functional groups allow hydrogen bond between the surface of CNT and water molecules to form, rendering the CNT hydrophilic. To turn them hydrophobic, adsorbed oxygen must be removed from the surface of CNT. Here we employ vacuum annealing treatment to induce oxygen desorption process. CNT arrays with extremely low surface concentration of oxygen adsorbates exhibit a superhydrophobic behavior.
Collapse
|
40
|
Khatami SF, Parvaresh P, Parvaresh P, Gharib M. The investigation of effects of blood exchange transfusion on selenium in newborn infants by instrumental neutron activation analysis method. IRANIAN JOURNAL OF PEDIATRICS 2013; 23:131-7. [PMID: 23724171 PMCID: PMC3663301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/23/2012] [Accepted: 11/17/2012] [Indexed: 10/26/2022]
Abstract
OBJECTIVE The evidence for the effects of blood exchange transfusion on selenium (Se) in newborn infants is unknown. This study was conducted to determine the possible effects of blood exchange transfusion on Se by comparing the Se blood concentrations before and after exchange transfusion in jaundiced neonates. METHODS A total of 30 jaundiced term neonates who underwent blood exchange transfusion (EXT) for first time because of idiopathic unconjugated hyperbilirubinemia, were recruited. The Se level of 30 blood bank donors' samples used for EXT were measured and 30 pairs of uncontaminated umbilical cord blood samples were investigated for Se before and after exchange transfusion. The samples were analyzed by instrumental neutron activation analysis method. Serum bilirubin concentrations were measured by venous blood samples before EXT. FINDINGS The average of Se concentration before EXT was higher than that after EXT (629.78±283.82 SD ppb versus 454.83±213.75 SD ppb) (P<0.05). There was significant correlation between the blood concentration of Se before and after EXT and also between the blood level of Se before EXT and total serum bilirubin level (P<0.05). There was no significant correlation between the blood concentration of Se before EXT and babies' gender and weight (P>0.05). The average Se level in samples obtained from transfused blood products was 507.90±223.56 SD ppb. CONCLUSION Blood exchange transfusion caused a 28% decrease of the blood Se level because the blood donors had lower blood Se levels than the newborns. Furthermore, there was a significant correlation between the blood level of Se before EXT and the total serum bilirubin level.
Collapse
|
41
|
Jamalipour M, Sayareh R, Gharib M, Khoshahval F, Karimi MR. Quantum behaved Particle Swarm Optimization with Differential Mutation operator applied to WWER-1000 in-core fuel management optimization. ANN NUCL ENERGY 2013. [DOI: 10.1016/j.anucene.2012.11.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
42
|
Armozd HR, Gharib M, Afarideh H, Ghergherehchi M, Niar AA, Jafarzadeh M. Determination of Tehran Research Reactor power by 16N gamma detection. ANN NUCL ENERGY 2011. [DOI: 10.1016/j.anucene.2011.08.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
43
|
Kim D, Gharib M. Characteristics of vortex formation and thrust performance in drag-based paddling propulsion. ACTA ACUST UNITED AC 2011; 214:2283-91. [PMID: 21653822 DOI: 10.1242/jeb.050716] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Several characteristics of drag-based paddling propulsion are studied with a simple mechanical model and a measurement technique for mapping three-dimensional flow fields. In drag-based propulsion, the temporal change of the vortex strength is an important parameter in the relationship between vortex formation and thrust generation. Our results indicate that spanwise flow behind the paddling propulsor significantly affects tip vortex development and thrust generation. The distribution of spanwise flow is dependent on the propulsor shape and the Reynolds number. A delta-shaped propulsor generates strong spanwise flow compared with a rectangular propulsor. For the low Reynolds number case, spanwise flow is not as strong as that for the high Reynolds number case. Without sacrificing total impulse, the flexible propulsor can smooth out thrust peaks during sudden stroke motions, which is favorable for avoiding structural failures and stabilizing body motion. We also explored the role of stopping vortex shedding in efficient thrust generation by determining the relationship between stroke angles and total impulses generated by paddling propulsors.
Collapse
|
44
|
Pahlevan NM, Gharib M. Aortic wave dynamics and its influence on left ventricular workload. PLoS One 2011; 6:e23106. [PMID: 21853075 PMCID: PMC3154923 DOI: 10.1371/journal.pone.0023106] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2011] [Accepted: 07/06/2011] [Indexed: 11/21/2022] Open
Abstract
The pumping mechanism of the heart is pulsatile, so the heart generates pulsatile flow that enters into the compliant aorta in the form of pressure and flow waves. We hypothesized that there exists a specific heart rate at which the external left ventricular (LV) power is minimized. To test this hypothesis, we used a computational model to explore the effects of heart rate (HR) and aortic rigidity on left ventricular (LV) power requirement. While both mean and pulsatile parts of the pressure play an important role in LV power requirement elevation, at higher rigidities the effect of pulsatility becomes more dominant. For any given aortic rigidity, there exists an optimum HR that minimizes the LV power requirement at a given cardiac output. The optimum HR shifts to higher values as the aorta becomes more rigid. To conclude, there is an optimum condition for aortic waves that minimizes the LV pulsatile load and consequently the total LV workload.
Collapse
|
45
|
Aria AI, Gharib M. Reversible tuning of the wettability of carbon nanotube arrays: the effect of ultraviolet/ozone and vacuum pyrolysis treatments. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:9005-11. [PMID: 21671597 DOI: 10.1021/la201841m] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Among diverse types of synthetic materials, arrays of vertically aligned carbon nanotubes have attracted the most attention, mainly because of their exceptional mechanical, electrical, optical, and thermal properties. However, their wetting properties are yet to be understood. In this present study, oxygenated surface functional groups have been identified as a vital factor in controlling the wetting properties of carbon nanotube arrays. The results presented herein indeed show that a combination of ultraviolet/ozone and vacuum pyrolysis treatments can be used to vary the surface concentration of these functional groups such that the carbon nanotube array can be repeatedly switched between hydrophilic and hydrophobic.
Collapse
|
46
|
Pahlevan NM, Gharib M. Low pulse pressure with high pulsatile external left ventricular power: influence of aortic waves. J Biomech 2011; 44:2083-9. [PMID: 21679951 DOI: 10.1016/j.jbiomech.2011.05.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2010] [Revised: 05/05/2011] [Accepted: 05/11/2011] [Indexed: 10/18/2022]
Abstract
Elevated pulse pressure (pp) is considered to be a risk factor for adverse cardiovascular events since it is directly related to an elevated myocardial workload. Information about both pressure and flow wave must be provided to assess hemodynamic complexity and true level of external left ventricular power (ELVP). pp value as a single feature of aortic waves cannot identify true level of ELVP. However, it is generally presumed that ELVP (and consequently LV workload) is positively correlated with pp. This study examined this positive correlation. The aim of this study was to test the hypothesis that aortic wave dynamics can create destructive hemodynamic conditions that increase the ELVP even though pp appears to be normal. To test this hypothesis, a computational model of the aorta with physiological properties was used. A Finite Element Method with fluid-structure interaction was employed to solve the equations of the solid and fluid. The aortic wall was assumed to be elastic and isotropic. The blood was assumed to be an incompressible Newtonian fluid. Simulations were performed for various heart rates (HR) and different aortic compliances while keeping the shape of the inlet flow and peripheral resistance constant. As expected, in most of the cases studied here, higher pp was associated with higher LV power demand. However, for a given cardiac output, mean pressure, and location of total reflection site, we have found cases where the above-mentioned trend does not hold. Our results suggest that using pp as a single index can result in an underestimation of the LV power demand under certain conditions related to the altered wave dynamics. Hence, in hypertensive patients, a full analysis of aortic wave dynamics is essential for the prevention and management of left ventricular hypertrophy (LVH) and congestive heart failure.
Collapse
|
47
|
Gharib M, Azizgolshani H, Gharib M, Liepmann D. Combined Electro‐chemical Stimulation to Reduce the Required Current for Muscle Contraction. FASEB J 2011. [DOI: 10.1096/fasebj.25.1_supplement.1051.39] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
48
|
Pahlevan NM, Amlani F, Hossein Gorji M, Hussain F, Gharib M. A physiologically relevant, simple outflow boundary model for truncated vasculature. Ann Biomed Eng 2011; 39:1470-81. [PMID: 21240638 DOI: 10.1007/s10439-011-0246-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2010] [Accepted: 01/03/2011] [Indexed: 11/29/2022]
Abstract
A realistic outflow boundary condition model for pulsatile flow in a compliant vessel is studied by taking into account physiological effects: compliance, resistance, and wave reflection of the downstream vasculature. The new model extends the computational domain with an elastic tube terminated in a rigid contraction. The contraction ratio, the length, and elasticity of the terminal tube can be adjusted to represent effects of the truncated vasculature. Using the wave intensity analysis method, we apply the model to the test cases of a straight vessel and the aorta and find good agreement with the physiological characteristics of blood flow and pressure. The model is suitable for cardiac transient (non-periodic) events and easily employed using so-called black box software.
Collapse
|
49
|
Gharib M, Arkani M, Hossnirokh A. Design and application of MTR fuel assemblies in new proposed inverted mode. NUCLEAR ENGINEERING AND DESIGN 2010. [DOI: 10.1016/j.nucengdes.2010.05.044] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
50
|
Lin BA, Forouhar AS, Pahlevan NM, Anastassiou CA, Grayburn PA, Thomas JD, Gharib M. Color Doppler Jet Area Overestimates Regurgitant Volume when Multiple Jets are Present. J Am Soc Echocardiogr 2010; 23:993-1000. [DOI: 10.1016/j.echo.2010.06.011] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2010] [Indexed: 11/29/2022]
|