26
|
AlAli M, Silikas N, Satterthwaite J. The Effects of Toothbrush Wear on the Surface Roughness and Gloss of Resin Composites with Various Types of Matrices. Dent J (Basel) 2021; 9:dj9010008. [PMID: 33445457 PMCID: PMC7827053 DOI: 10.3390/dj9010008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 01/05/2021] [Accepted: 01/08/2021] [Indexed: 01/31/2023] Open
Abstract
Objective: To evaluate and compare the surface roughness and gloss of a DMA-free composite and Bis-GMA-free composite with a DMA-based composite before and after toothbrushing simulation. Materials and Methods: Fifteen dimensionally standardised composite specimens of three nano-hybrid resin composites (Tetric EvoCeram, Admira Fusion, and Venus Diamond) were used. Five specimens from each composite were polished and then subjected to a toothbrushing simulator. Surface roughness (Ra) and gloss were measured before toothbrushing and after 5000, 10,000, 15,000, and 20,000 toothbrushing cycles. The data was analysed using 5 × 3 ANOVA to assess surface roughness and gloss values and pairwise comparisons in the form of Tukey post hoc tests were performed to interpret main effects. Results: For all tested materials, surface roughness increased, and gloss decreased after toothbrushing abrasion. Surface roughness (Ra) values ranged from 0.14 to 0.22 μm at baseline and increased to between 0.41 and 0.49 μm after 20,000 toothbrushing cycles. Gloss values ranged between 31.9 and 50.6 GU at baseline and between 5.1 and 19.5 GU after 20,000 toothbrushing cycles. The lowest initial Ra value was detected in Venus Diamond and the highest initial gloss value was detected in Tetric EvoCeram. Conclusions: Simulated toothbrushing abrasion led to an increase in surface roughness and a decrease in gloss for all tested materials. Venus Diamond had the smoothest surface and Tetric EvoCeram had the glossiest surface after polishing and following 20,000 cycles of toothbrushing abrasion. Admira Fusion demonstrated the roughest surface and had the lowest gloss values before and after toothbrushing abrasion.
Collapse
|
27
|
Agarwalla SV, Ellepola K, Silikas N, Castro Neto AH, Seneviratne CJ, Rosa V. Persistent inhibition of Candida albicans biofilm and hyphae growth on titanium by graphene nanocoating. Dent Mater 2020; 37:370-377. [PMID: 33358443 DOI: 10.1016/j.dental.2020.11.028] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 10/30/2020] [Accepted: 11/26/2020] [Indexed: 01/01/2023]
Abstract
OBJECTIVES Candida albicanscolonizes biomaterial surfaces and are highly resistant to therapeutics. Graphene nanocoating on titanium compromises initial biofilm formation. However, its sustained antibiofilm potential is unknown. The objective of this study was to investigate the potential of graphene nanocoating to decrease long-term fungal biofilm development and hyphae growth on titanium. METHODS Graphene nanocoating was deposited twice (TiGD) or five times (TiGV) on grade 4 titanium with vacuum assisted technique and characterized with Raman spectroscopy and atomic force microscope. The biofilm formation and hyphae growth of C. albicans was monitored for seven days by CFU, XTT, confocal, mean cell density and scanning electronic microscopy (SEM). Uncoated titanium was the Control. All tests had three independent biological samples and were performed in independent triplicates. Data was analyzed with one- or two-way ANOVA and Tukey's HSD (α = 0.05). RESULTS Both TiGD and TiGV presented less biofilms at all times points compared with Control. The confocal and SEM images revealed few adhered cells on graphene coated samples, absence of hyphae and no features of a mature biofilm architecture. The increase in number of layers of graphene nanocoating did not improve its antibiofilm potential. SIGNIFICANCE The graphene nanocoating exerted a long-term persistent inhibitory effect on the biofilm formation on titanium. The fewer cells that were able to attach on graphene coated titanium were scattered and unable to form a mature biofilm with hyphae elements. The findings open opportunities to prevent microbial attachment and proliferation on implantable materials without the use of antibiotics.
Collapse
|
28
|
Zidan S, Silikas N, Haider J, Alhotan A, Jahantigh J, Yates J. Assessing Tensile Bond Strength Between Denture Teeth and Nano-Zirconia Impregnated PMMA Denture Base. Int J Nanomedicine 2020; 15:9611-9625. [PMID: 33293810 PMCID: PMC7718964 DOI: 10.2147/ijn.s273541] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 09/10/2020] [Indexed: 11/24/2022] Open
Abstract
Purpose This study evaluated tensile bond strength (TBS) between anterior acrylic teeth and denture bases made of high-impact heat-cured acrylic resin (HI PMMA) impregnated with zirconia nanoparticles. Materials and Methods A total of 30 specimens (each specimen containing a set of six upper anterior teeth) were fabricated from HI PMMA denture base acrylic resin reinforced with different weight concentrations of zirconia nanoparticles: 0% (control), 1.5%, 3%, 5%, 7% and 10%. TBS was tested according to a British standard (BS EN ISO 22112: 2017). A one-way analysis of variance (ANOVA) was employed with a Tukey post-hoc test. Results TBS values between the anterior teeth (central and lateral incisors and canine) and HI-PMMA denture base groups containing 7 wt.% (261.5 ± 66.0 N, 172.5 ± 57.4 N and 271.9 ± 86.3 N) and 10 wt.% (332.1 ± 122.9 N, 165.4 ± 48.7 N and 301.6 ± 73.2 N) zirconia were significantly lower compared to the control group (645.4 ± 84.8 N, 306.1 ± 81.6 N and 496.7 ± 179.1 N) and the other nanocomposite groups. However, TBS values for HI PMMA with 1.5 wt.% (534.4 ± 115.3 N, 304.7 ± 86.4 N, 514.0 ± 143.2 N), 3 wt.% (685.7 ± 159.6 N, 281.1 ± 78.3 N, 462.6 ± 122.1 N) and 5 wt.% (514.5 ± 134.3 N, 229.8 ± 67.3 N, 387.2 ± 99.4 N) zirconia showed slightly lower values than that of the control group but these were not significant. Failure modes between the teeth and denture base nanocomposites were predominantly cohesive fractures, which were clinically acceptable according to the Standard. Conclusion The addition of zirconia nanoparticles to HI PMMA denture base at high concentration (7 wt.% and 10 wt. %) significantly (p<0.05) reduced the bonding strength for all types of anterior teeth compared to the control group.
Collapse
|
29
|
Algamaiah H, Silikas N, Watts DC. Conversion kinetics of rapid photo-polymerized resin composites. Dent Mater 2020; 36:1266-1274. [DOI: 10.1016/j.dental.2020.07.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 07/21/2020] [Accepted: 07/21/2020] [Indexed: 10/23/2022]
|
30
|
Zidan S, Silikas N, Haider J, Yates J. Long-Term Sorption and Solubility of Zirconia-Impregnated PMMA Nanocomposite in Water and Artificial Saliva. MATERIALS 2020; 13:ma13173732. [PMID: 32847026 PMCID: PMC7503455 DOI: 10.3390/ma13173732] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 08/17/2020] [Accepted: 08/20/2020] [Indexed: 11/30/2022]
Abstract
Exposure of denture base acrylic resins to the oral environment and storage media for extended periods of time results in sorption of saliva or water, leading to a reduction in physical properties and thus clinical service life. The purpose of this in vitro study was to assess the sorption and solubility of high-impact heat-polymerised denture base acrylic resin (HI PMMA) impregnated with zirconia nanoparticles after being stored for 180 days in distilled water (DW) and artificial saliva (AS). The specimens were divided into six groups for each storage medium, according to the concentration of zirconia nanoparticles (0, 1.5, 3.0, 5.0, 7.0, and 10.0 wt.%). Data were statistically analysed for sorption and solubility using one-way and two-way ANOVA statistical tests. Sorption in DW and AS for all groups containing zirconia showed sorption values lower than the control group at 90 days, though not significantly different (p > 0.05) compared to the control group. For both the DW and AS groups, the lowest solubility value was measured in the group containing 3 wt.% zirconia, however, there was no significant difference compared to the control group except when observing 10 wt.% zirconia in AS, which showed a significantly higher solubility (p < 0.05). High-impact PMMA, impregnated with low concentrations of ZrO2, showed the lowest sorption and solubility in both media, but was not significantly different compared to pure HI PMMA.
Collapse
|
31
|
Yang J, Silikas N, Watts DC. Pre-heating time and exposure duration: Effects on post-irradiation properties of a thermo-viscous resin-composite. Dent Mater 2020; 36:787-793. [DOI: 10.1016/j.dental.2020.03.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 03/26/2020] [Accepted: 03/27/2020] [Indexed: 10/24/2022]
|
32
|
Althaqafi KA, Satterthwaite J, Silikas N. A review and current state of autonomic self-healing microcapsules-based dental resin composites. Dent Mater 2020; 36:329-342. [DOI: 10.1016/j.dental.2019.12.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 12/11/2019] [Accepted: 12/11/2019] [Indexed: 11/30/2022]
|
33
|
Dimitriadi M, Zinelis S, Zafiropoulou M, Silikas N, Eliades G. Self-Etch Silane Primer: Reactivity and Bonding with a Lithium Disilicate Ceramic. MATERIALS 2020; 13:ma13030641. [PMID: 32023979 PMCID: PMC7040894 DOI: 10.3390/ma13030641] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 01/26/2020] [Accepted: 01/30/2020] [Indexed: 11/18/2022]
Abstract
The aim of the study was to evaluate the stability, reactivity, and bond strength with a lithium disilicate ceramic of a self-etch silane primer (Monobond Etch and Prime/MEP). The stability was evaluated by 1H-,31P-NMR spectroscopy (before/after aging), and the reactivity by micro MIR-FTIR spectroscopy on Ge surfaces (0, 1, 24 h) using a prehydrolyzed silane primer (Calibra Silane Coupling Agent/CLB), as a control. The effect of MEP vs. 5% HF-etching on ceramic roughness was assessed by optical profilometry. The shear bond strength (SBS) of a resin composite bonded to polished ceramic surfaces treated with MEP, HF without silane (HF+NS), HF+CLB, and HF+MEP (n = 20) was evaluated after storage in water (A: 37 °C/1 week, B: 5000×/5–55 °C and C: 100 °C/24 h). Aging did not affect the silanol groups of MEP, but only the phosphate co-monomer. Silanols were reactive forming siloxanes, but exhibited lower consumption rate than CLB. HF-etching induced significantly higher values than MEP, in all the roughness parameters tested (Sa, Sz, Sdr, Sc, Sv), with the greatest differences found in Sdr and Sv. For SBS, MEP was inferior to all treatments/storage conditions, except of HF+NS in A, where the values were similar. However, on a HF-etched substrate, MEP provided highest strength and reliability.
Collapse
|
34
|
Ashy LM, Marghalani H, Silikas N. In Vitro Evaluation of Marginal and Internal Adaptations of Ceramic Inlay Restorations Associated with Immediate vs Delayed Dentin Sealing Techniques. INT J PROSTHODONT 2019; 33:48-55. [PMID: 31860913 DOI: 10.11607/ijp.6372] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE To investigate the marginal and internal adaptations of ceramic inlay restorations placed with immediate dentin sealing (IDS) vs delayed dentin sealing (DDS) procedures. MATERIALS AND METHODS Mesial and distal Class II cavities were prepared in 12 extracted molar teeth, which were randomly allocated into six groups of 2 teeth each. Lava Ultimate inlays were fabricated and luted to the cavities using All-Bond universal adhesive system and eCEMENT dual-curing resin cement following IDS/immediate cementation (control groups 1 and 2), IDS/delayed cementation (groups 3 and 4), or DDS/delayed cementation (groups 5 and 6) protocols. Teeth in groups 2, 4, and 6 were subjected to thermocycling of 500 cycles between 5°C and 55°C after inlay cementation. Following staining with silver nitrate solution, the marginal and internal gap volumes were determined using microcomputed tomography images. Statistical analyses were conducted using independent t test and one-way analysis of variance followed by Tukey post hoc test (P < .05). RESULTS Marginal gap volume for DDS (1.856 ± 0.323 mm3) was significantly higher than that of IDS immediately after inlay cementation (0.891 ± 0.281 mm3) (P = .025). Following thermocycling, the internal gap volume for DDS (0.838 ± 0.248 mm3) was significantly higher than that for IDS (0.098 ± 0.066 mm3) (P = .000), but the marginal gap volume of DDS (1.964 ± 0.956 mm3) was not significantly different from that of IDS (1.426 ± 0.725 mm3) (P = .622). CONCLUSION Luted ceramic inlays have a superior marginal adaptation right after cementation and a superior internal adaptation after thermocycling when using the IDS technique compared to the DDS technique. However, marginal adaptation after thermocycling was not significantly different between the two techniques.
Collapse
|
35
|
Wagstaffe M, Hussain H, Taylor M, Murphy M, Silikas N, Thomas AG. Interaction of a tripeptide with titania surfaces: RGD adsorption on rutile TiO 2(110) and model dental implant surfaces. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 105:110030. [PMID: 31546374 DOI: 10.1016/j.msec.2019.110030] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 07/01/2019] [Accepted: 07/28/2019] [Indexed: 01/04/2023]
Abstract
The adsorption of peptides on metal oxides is an area of significant interest, both fundamentally and in a number of technologically important areas. These range from the integration of biomaterials in the body, to denaturation of protein therapeutics and the use of biomolecules and bioinspired materials in synthesis and stabilization of novel nanomaterials. Here we present a study of the tripeptide arginylglycylaspartic acid (RGD) on the surfaces of vacuum-prepared single crystalline TiO2(110), pyrocatechol-capped TiO2(110), and model SLA and SLActive dental implant samples. X-ray Photoelectron Spectroscopy and Scanning Tunneling Microscopy show that the RGD adsorption mode on the single crystal is consistent with bonding through the deprotonated carboxylate groups of the peptide to surface Ti atoms of the substrate. Despite the increased hydrophobicity of the pyrocatechol-capped TiO2(110) surface RGD adsorption from solution increases following this surface treatment. RGD adsorption on SLA and SLActive surfaces shows that the SLActive surface has a greater uptake of RGD. The RGD uptake on the pyrocatechol capped single crystal and the model implant surfaces suggest that the ease with which surface contaminant hydrocarbons are removed from the surface has a greater influence on peptide adsorption than hydrophobicity/hydrophilicity of the surface.
Collapse
|
36
|
Velo MMAC, Nascimento TRL, Scotti CK, Bombonatti JFS, Furuse AY, Silva VD, Simões TA, Medeiros ES, Blaker JJ, Silikas N, Mondelli RFL. Improved mechanical performance of self-adhesive resin cement filled with hybrid nanofibers-embedded with niobium pentoxide. Dent Mater 2019; 35:e272-e285. [PMID: 31519351 DOI: 10.1016/j.dental.2019.08.102] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 07/25/2019] [Accepted: 08/20/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVES In this study hybrid nanofibers embedded with niobium pentoxide (Nb2O5) were synthesized, incorporated in self-adhesive resin cement, and their influence on physical-properties was evaluated. METHODS Poly(D,L-lactide), PDLLA cotton-wool-like nanofibers with and without silica-based sol-gel precursors were formulated and spun into submicron fibers via solution blow spinning, a rapid fiber forming technology. The morphology, chemical composition and thermal properties of the spun fibers were characterized by field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS) and Fourier-transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC), respectively. Produced fibers were combined with a self-adhesive resin cement (RelyX U200, 3M ESPE) in four formulations: (1) U200 resin cement (control); (2) U200+1wt.% PDLLA fibers; (3) U200+1wt.% Nb2O5-filled PDLLA composite fibers and (4) U200+1wt.% Nb2O5/SiO2-filled PDLLA inorganic-organic hybrid fibers. Physical properties were assessed in flexure by 3-point bending (n=10), Knoop microhardness (n=5) and degree of conversion (n=3). Data were analyzed with One-way ANOVA and Tukey's HSD (α=5%). RESULTS Composite fibers formed of PDLLA-Nb2O5 exhibited an average diameter of ∼250nm, and hybrid PDLLA+Nb2O5/SiO2 fibers were slightly larger, ∼300nm in diameter. There were significant differences among formulations for hardness and flexural strength (p<0.05). Degree of conversion of resin cement was not affected for all groups, except for Group 4 (p<0.05). SIGNIFICANCE Hybrid reinforcement nanofibers are promising as fillers for dental materials. The self-adhesive resin cement with PDLLA+Nb2O5 and PDLLA+Nb2O5/SiO2 presented superior mechanical performance than the control group.
Collapse
|
37
|
Zidan S, Silikas N, Alhotan A, Haider J, Yates J. Investigating the Mechanical Properties of ZrO 2-Impregnated PMMA Nanocomposite for Denture-Based Applications. MATERIALS 2019; 12:ma12081344. [PMID: 31027157 PMCID: PMC6515448 DOI: 10.3390/ma12081344] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 04/18/2019] [Accepted: 04/20/2019] [Indexed: 12/16/2022]
Abstract
Acrylic resin PMMA (poly-methyl methacrylate) is used in the manufacture of denture bases but its mechanical properties can be deficient in this role. This study investigated the mechanical properties (flexural strength, fracture toughness, impact strength, and hardness) and fracture behavior of a commercial, high impact (HI), heat-cured denture base acrylic resin impregnated with different concentrations of yttria-stabilized zirconia (ZrO2) nanoparticles. Six groups were prepared having different wt% concentrations of ZrO2 nanoparticles: 0% (control), 1.5%, 3%, 5%, 7%, and 10%, respectively. Flexural strength and flexural modulus were measured using a three-point bending test and surface hardness was evaluated using the Vickers hardness test. Fracture toughness and impact strength were evaluated using a single edge bending test and Charpy impact instrument. The fractured surfaces of impact test specimens were also observed using a scanning electron microscope (SEM). Statistical analyses were conducted on the data obtained from the experiments. The mean flexural strength of ZrO2/PMMA nanocomposites (84 ± 6 MPa) at 3 wt% zirconia was significantly greater than that of the control group (72 ± 9 MPa) (p < 0.05). The mean flexural modulus was also significantly improved with different concentrations of zirconia when compared to the control group, with 5 wt% zirconia demonstrating the largest (23%) improvement. The mean fracture toughness increased in the group containing 5 wt% zirconia compared to the control group, but it was not significant. However, the median impact strength for all groups containing zirconia generally decreased when compared to the control group. Vickers hardness (HV) values significantly increased with an increase in ZrO2 content, with the highest values obtained at 10 wt%, at 0 day (22.9 HV0.05) in dry conditions when compared to the values obtained after immersing the specimens for seven days (18.4 HV0.05) and 45 days (16.3 HV0.05) in distilled water. Incorporation of ZrO2 nanoparticles into high impact PMMA resin significantly improved flexural strength, flexural modulus, fracture toughness and surface hardness, with an optimum concentration of 3–5 wt% zirconia. However, the impact strength of the nanocomposites decreased, apart from the 5 wt% zirconia group.
Collapse
|
38
|
Alrahlah A, Khan R, Alotaibi K, Almutawa Z, Fouad H, Elsharawy M, Silikas N. Simultaneous Evaluation of Creep Deformation and Recovery of Bulk-Fill Dental Composites Immersed in Food-Simulating Liquids. MATERIALS 2018; 11:ma11071180. [PMID: 29996519 PMCID: PMC6073768 DOI: 10.3390/ma11071180] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 06/27/2018] [Accepted: 06/28/2018] [Indexed: 11/16/2022]
Abstract
The aim of this study is to compare the creep/recovery behavior of bulk-fill dental composites after storage in various food simulating organic solvents. For this purpose, five different resin-composites (four bulk-fills and one conventional) were used. A total of 20 rectangular specimens (14 mm × 3 mm × 0.7 mm) were prepared by filling the resin-composites in Teflon mold. All of the specimens for each material (n = 5) were divided into four groups namely dry (control), distilled water (DW), artificial saliva, and absolute ethanol. The specimens were subjected to three-point bending creep test during immersion directly. A constant load of 2 N was used for each specimen with loading and unloading time 2 h each. RESULTS SF2 and XF showed a lower creep strain % after immersion, ranging from 0.44 (dry) to 0.75 (saliva) and 0.43 (dry) to 0.80 (ethanol), respectively. TNC BF depicts the maximum creep strain % ranging from 1.24% (dry) to 2.87% (ethanol) followed by FBF ranging from 1.17 (dry) to 2.59 (ethanol). However, the conventional material (GR) showed lower creep strain after immersion ranging from 0.28 to 0.54. Moreover, SF2 resulted in the highest creep recovery in all of the composites groups, as well as conventional material. The other composite groups showed lower creep recovery as compared to the conventional material (GR). The creep strain % for all the bulk-fill composites materials were increased during immersion in the liquids. However, for the conventional material, the creep deformation is decreased after immersion. SF2 showed the highest percentage of creep recovery among the bulk-fill composites, followed by XF.
Collapse
|
39
|
Solheiro L, Moura K, Rifane T, Silvestre F, Moreira M, Souza M, Zanotto E, Silikas N, Feitosa V. Bioactive glasses may interfere on dentin adhesion of experimental composites. Dent Mater 2018. [DOI: 10.1016/j.dental.2018.08.239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
40
|
Velo M, Scotti C, Nascimento T, Mondelli R, Silva V, Simões T, Medeiros E, Blaker J, Silikas N. Performance of self-adhesive resin-cement by cotton-wool-like nanofibers-embedded with niobium. Dent Mater 2018. [DOI: 10.1016/j.dental.2018.08.259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
41
|
Ferracane J, Hilton T, Stansbury J, Watts D, Silikas N, Ilie N, Heintze S, Cadenaro M, Hickel R. Academy of Dental Materials guidance—Resin composites: Part II—Technique sensitivity (handling, polymerization, dimensional changes). Dent Mater 2017; 33:1171-1191. [DOI: 10.1016/j.dental.2017.08.188] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Accepted: 08/29/2017] [Indexed: 11/30/2022]
|
42
|
Ilie N, Hilton TJ, Heintze SD, Hickel R, Watts DC, Silikas N, Stansbury JW, Cadenaro M, Ferracane JL. Academy of Dental Materials guidance-Resin composites: Part I-Mechanical properties. Dent Mater 2017; 33:880-894. [PMID: 28577893 DOI: 10.1016/j.dental.2017.04.013] [Citation(s) in RCA: 167] [Impact Index Per Article: 23.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Accepted: 04/21/2017] [Indexed: 10/19/2022]
Abstract
OBJECTIVE The objective of this project, which was initiated from the Academy of Dental Materials, was to review and critically appraise methods to determine fracture, deformation and wear resistance of dental resin composites, in an attempt to provide guidance for investigators endeavoring to study these properties for these materials. METHODS Test methods have been ranked in the priority of the specific property being tested, as well as of the specific test methods for evaluating that property. Focus was placed on the tests that are considered to be of the highest priority in terms of being the most useful, applicable, supported by the literature, and which show a correlation with clinical findings. Others are mentioned briefly for the purpose of being inclusive. When a standard test method exists, including those used in other fields, these have been identified in the beginning of each section. Also, some examples from the resin composite literature are included for each test method. RESULTS The properties for evaluating resin composites were ranked in the priority of measurement as following: (1) Strength, Elastic Modulus, Fracture toughness, Fatigue, Indentation Hardness, Wear-abrasion (third body) and Wear-attrition (contact/two body), (2) Toughness, Edge strength (chipping) and (3) Wear determined by toothbrush. SIGNIFICANCE The following guidance is meant to aid the researcher in choosing the proper method to assess key properties of dental resin composites with regard to their fracture, deformation and wear resistance.
Collapse
|
43
|
Murphy M, Walczak M, Thomas A, Silikas N, Berner S, Lindsay R. Toward optimizing dental implant performance: Surface characterization of Ti and TiZr implant materials. Dent Mater 2017; 33:43-53. [DOI: 10.1016/j.dental.2016.10.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Revised: 09/29/2016] [Accepted: 10/09/2016] [Indexed: 01/05/2023]
|
44
|
Alamoush R, Satterthwaite J, Silikas N. Analysis of monomer elution from CAD/CAM hybrid ceramics using HPLC. Dent Mater 2017. [DOI: 10.1016/j.dental.2017.08.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
45
|
Papadogiannis D, Iliadi A, Bradley TG, Silikas N, Eliades G, Eliades T. Viscoelastic properties of orthodontic adhesives used for lingual fixed retainer bonding. Dent Mater 2016; 33:e22-e27. [PMID: 27769593 DOI: 10.1016/j.dental.2016.09.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 09/14/2016] [Accepted: 09/27/2016] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To evaluate the viscoelastic properties of two experimental BPA-free and one BisGMA-based orthodontic resin composite adhesives for bonding fixed retainers. METHODS A commercially available BisGMA-based (TXA: Transbond LR) and two bisphenol A-free experimental adhesives (EXA and EXB) were included in the study. The viscoelastic behavior of the adhesives was evaluated under static and dynamic conditions at dry and wet states and at various temperatures (21, 37, 50°C). The parameters determined were shear modulus (G), Young's modulus (E) under static testing and storage modulus (G1), loss tangent (tanδ) and dynamic viscosity (n*) under dynamic testing. Statistical analysis was performed by 2-way ANOVA and Bonferroni post-hoc tests (α=0.05). RESULTS For static testing, a significant difference was found within material and storage condition variables and a significant interaction between the two independent variables (p<0.001 for G and E). EXA demonstrated the highest G and E values at 21°C/dry group. Dry specimens showed the highest G and E values, but with no significant difference from 21°C/wet specimens, except EXA in G. Wet storage at higher temperatures (37°C and 50°C) adversely affected all the materials to a degree ranging from 40 to 60% (p<0.001). For dynamic testing, a significant difference was also found in material and testing condition groups, with a significant interaction between the two independent variables (p<0.001 for G1 and n*, p<0.01 for tanδ). Reduction in G1, and n* values, and increase in tanδ values were encountered at increased water temperatures. SIGNIFICANCE The apparent detrimental effect of high temperature on the reduction of properties of adhesives may contribute to the loss of stiffness of the fixed retainer configuration under ordinary clinical conditions with unfavorable effects on tooth position and stability of the orthodontic treatment result.
Collapse
|
46
|
Arpa C, Ceballos L, Watts D, Silikas N. 3-D hygroscopic expansion of resin-composites. Dent Mater 2016. [DOI: 10.1016/j.dental.2016.08.081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
47
|
Bacchi A, Feitosa VP, da Silva Fonseca ASQ, Cavalcante LMA, Silikas N, Schneider LFJ. Shrinkage, stress, and modulus of dimethacrylate, ormocer, and silorane composites. J Conserv Dent 2015; 18:384-8. [PMID: 26430302 PMCID: PMC4578183 DOI: 10.4103/0972-0707.164051] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Purpose: to evaluate the shrinkage, polymerization stress, elastic and bulk modulus resulting from composites formulated by siloranes, 2nd generation ormocers, and dimethacrylates. Materials and Methods: The bonded disc method was used to evaluate volumetric shrinkage. The polymerization stress was evaluated by mean of the Bioman. Cylindrical specimens (5 mm thickness and 6 mm diameter) were submitted to gradual loading. Young's and bulk modulus were obtained from the slope of the stress/strain curve. Data were analyzed using one-way analysis of variance and Tukey's test (5%). Results: Grandio and ormocer showed significant higher elastic and bulk modulus. Silorane presented significant lowest bulk modulus and maximum shrinkage. Ormocer and silorane presented lower values for the maximum rate of shrinkage. Extra-low shrinkage (ELS) composite presented the greatest maximum shrinkage. The higher maximum rate of shrinkage was attained by Grandio and ELS, statistically similar from each other. The silorane showed lower values of maximum stress and maximum rate of stress. The higher values of maximum stress were presented by ELS and Grandio, statistical similar between them. Grandio showed the significantly greatest maximum rate of stress. Conclusion: Silorane showed to promote lower shrinkage/stress among the composites, with the lowest elastic modulus. Ormocer showed lower shrinkage/stress than methacrylates despite of its high modulus.
Collapse
|
48
|
Al-Haddad A, Satterthwaite J, Silikas N. Influence of fibre-reinforcement on light-transmittance and microhardness of bulk-fill resin-composites. Dent Mater 2015. [DOI: 10.1016/j.dental.2015.08.058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
49
|
Al-Ahdal K, Silikas N, Watts D. Effects of composition and temperature on rheology of model resin-composites. Dent Mater 2014. [DOI: 10.1016/j.dental.2014.08.094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
50
|
Alrahlah A, Silikas N, Watts DC. Post-cure depth of cure of bulk fill dental resin-composites. Dent Mater 2013; 30:149-54. [PMID: 24268044 DOI: 10.1016/j.dental.2013.10.011] [Citation(s) in RCA: 141] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2013] [Revised: 10/31/2013] [Accepted: 10/31/2013] [Indexed: 11/16/2022]
Abstract
OBJECTIVES To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). METHODS Five bulk fill composite materials were examined: Tetric EvoCeram(®) Bulk Fill, X-tra base, Venus(®) Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37°C for 24h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests (α=0.05). RESULTS The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN (p<0.001) while Venus Bulk Fill the lowest (p≤0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill (p≤0.016). Linear regression confirmed a positive regression between max.VHN and filler loading (r(2)=0.94). SIGNIFICANCE Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers' claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined.
Collapse
|