26
|
Tsilimparis N, Gouveia E Melo R. To Scallop or Not to Scallop in the Arch? Is This the Question? Eur J Vasc Endovasc Surg 2023; 66:830-831. [PMID: 37611732 DOI: 10.1016/j.ejvs.2023.08.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 08/17/2023] [Indexed: 08/25/2023]
|
27
|
Konstantinou N, Argyriou A, Dammer F, Bisdas T, Chlouverakis G, Torsello G, Tsilimparis N, Stavroulakis K. Outcomes After Open Surgical, Hybrid, and Endovascular Revascularization for Acute Limb Ischemia. J Endovasc Ther 2023:15266028231210232. [PMID: 38009372 DOI: 10.1177/15266028231210232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2023]
Abstract
PURPOSE To report the performance of surgical treatment (ST), hybrid treatment (HT), and endovascular treatment (ET) for patients with acute limb ischemia (ALI). METHODS This is a retrospective, comparative study of all consecutive patients with ALI treated in 2 tertiary centers between April 2010 and April 2020. Amputation and/or death (amputation-free survival; AFS) was the primary composite endpoint. Mortality, major amputation, and reintervention during follow-up were additionally analyzed. Proportional hazards modeling was used to identify confounders, results are presented as hazard ratio (HR) and 95% confidence intervals (CIs). RESULTS In total, 395 patients (mean age=71.1±13.6 years; 51.1% female) were treated during the study period. Surgical treatment was preferred in 150 patients (38%), while 98 were treated by HT (24.8%) and 147 by ET (37.2%). Rutherford class IIa was the most common clinical presentation in the ET group (50.3%), whereas Rutherford IIb was most common in the ST (54%) and HT (48%) groups (p<0.001). Significantly, more patients presented with a de novo lesion in the ST and HT groups (79.3% and 64.3%, respectively) compared with ET (53.7%; p<0.001). Median follow-up was 20 months (range=0-111 months). In the multivariate analysis, ET showed significantly better AFS during follow-up compared with ST (HR=1.89, 95% CI=1.2-2.9, p<0.001) and HT (HR=1.73, 95% CI=1.1-3.1, p<0.001). Mortality during follow-up was also significantly lower after ET compared with ST (HR=2.21, 95% CI=1.31-3.74, p=0.003) and HT (HR=2.04, 95% CI=1.17-3.56, p=0.012). Endovascular treatment was associated with lower amputation rate compared with ST (HR=2.27, 95% CI=1.19-4.35, p=0.013) but was comparable with HT (HR=2.00, 95% CI=0.98-4.06, p=0.055). Reintervention rates did not differ significantly between the groups (ET vs ST: HR=1.52, 95% CI=0.99-2.31, p=0.053; ET vs HT: HR=1.3, 95% CI=0.81-2.07, p=0.27). CONCLUSION Endovascular treatment for ALI was associated with improved AFS and comparable reintervention rates compared with open surgical and hybrid therapy. CLINICAL IMPACT Treatment of acute lower limb ischemia remains a challenge for clinicians with high morbidity and mortality rates. Endovascular revascularization is considered first line treatment for many and hybrid treatments are becoming more common, however data is limited to either old trials, small series or with short follow-up. We present herein our 10-year experience with all available devices and techniques for open surgical, endovascular and hybrid acute limb ischemia treatments and compare their outcomes.
Collapse
|
28
|
Becker D, Stana J, Prendes CF, Konstantinou N, Öz T, Pichlmaier M, Peterss S, Tsilimparis N. Endovascular arch repair of anastomotic aneurysm and pseudoaneurysm in patients after open repair of the ascending aorta and aortic arch: a case series. Eur J Cardiothorac Surg 2023; 64:ezad345. [PMID: 37889250 DOI: 10.1093/ejcts/ezad345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 10/05/2023] [Indexed: 10/28/2023] Open
Abstract
OBJECTIVES The aim of the study was to investigate the outcomes of branched endovascular arch repair (b-TEVAR) with a custom-made double- or triple-branched arch endograft in patients with distal anastomotic aneurysms after open repair of the ascending aorta or proximal arch replacement. METHODS Retrospective analysis was conducted of all consecutive patients with anastomotic aneurysms after open surgical repair involving the ascending aorta and/or aortic arch treated with b-TEVAR. All patients were treated with a custom-made double or triple inner-branched arch endograft. Study end points were technical success, 30-day and follow-up mortality/morbidity and re-interventions. RESULTS Between 2018 and 2022, 10 patients were treated with custom-made double- or triple-branched thoracic endovascular aortic repair due to anastomotic aneurysms after open ascending aorta and/or proximal aortic arch replacement. Eight patients received a triple and 2 a double arch-branched endograft. Eight cases were performed electively and 2 urgently for contained rupture. Technical success was achieved in 9 cases (90%). All elective patients survived. Two patients treated due to contained ruptures expired. Within 30 postoperative days, 1 transient ischaemic attack occurred. No early endograft-related re-interventions were necessary. The median follow-up was 20 months. One patient died 2 months after discharge due to sepsis caused by pneumonia. No further deaths or endograft-related re-interventions were observed. CONCLUSIONS Endovascular aortic arch repair with double or triple inner-branched arch endograft for anastomotic aneurysms after open ascending and/or proximal arch replacement is technically feasible and a promising alternative in a patient cohort unfit for surgery.
Collapse
|
29
|
Dias-Neto M, Vacirca A, Huang Y, Baghbani-Oskouei A, Jakimowicz T, Mendes BC, Kolbel T, Sobocinski J, Bertoglio L, Mees B, Gargiulo M, Dias N, Schanzer A, Gasper W, Beck AW, Farber MA, Mani K, Timaran C, Schneider DB, Pedro LM, Tsilimparis N, Haulon S, Sweet MP, Ferreira E, Eagleton M, Yeung KK, Khashram M, Jama K, Panuccio G, Rohlffs F, Mesnard T, Chiesa R, Kahlberg A, Schurink GW, Lemmens C, Gallitto E, Faggioli G, Karelis A, Parodi E, Gomes V, Wanhainen A, Habib M, Colon JP, Pavarino F, Baig MS, Gouveia E Melo RECD, Crawford S, Zettervall SL, Garcia R, Ribeiro T, Alves G, Gonçalves FB, Kappe KO, Mariko van Knippenberg SE, Tran BL, Gormley S, Oderich GS. Outcomes of Elective and Non-elective Fenestrated-branched Endovascular Aortic Repair for Treatment of Thoracoabdominal Aortic Aneurysms. Ann Surg 2023; 278:568-577. [PMID: 37395613 DOI: 10.1097/sla.0000000000005986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2023]
Abstract
OBJECTIVE To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.
Collapse
|
30
|
Tsilimparis N, Gouveia E Melo R, Schanzer A, Sobocinski J, Austermann M, Chiesa R, Resch T, Gargiulo M, Timaran C, Maurel B, Adam D, Dias N, Oderich GS, Kölbel T, Gomez Palones F, Simonte G, Giudice R, Mesnard T, Loschi D, Leone N, Gallito E, Spath P, Porras Cólon J, Elboushi A, Wachtmeister M, Sonesson B, Tenorio E, Panuccio G, Isernia G, Bertoglio L. Transatlantic multicenter study on the use of a modified preloaded delivery system for fenestrated endovascular aortic repair. J Vasc Surg 2023; 78:863-873.e3. [PMID: 37330705 DOI: 10.1016/j.jvs.2023.05.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/23/2023] [Accepted: 05/24/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. METHODS A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. RESULTS Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. CONCLUSIONS The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.
Collapse
|
31
|
Walensi M, Krasniuk I, Tsilimparis N, Hoffmann JN. [Late Open Semi-conversion with Endograft Preservation for (Type II) Endoleaks with Late Aneurysm Sac Enlargement after EVAR - Indications, Method and Results in Our Own Patient Collective]. Zentralbl Chir 2023; 148:445-453. [PMID: 37846164 DOI: 10.1055/a-2174-7563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
EVAR (endovascular aortic repair) is the most common method for treating an abdominal aortic aneurysm, but according to the latest findings it carries the risk of subsequent complications. These can be caused by (late) aneurysm sac growth. If conservative and surgical therapies fail to treat the aneurysm sac growth, open conversion is necessary to prevent aneurysm rupture. There are several options for open conversion, in which the EVAR prosthesis can be completely preserved or is (partially) removed. Late open semi-conversion with complete in-situ preservation of the EVAR-prosthesis and gathering of the aneurysm sac are a less invasive method than complete conversion and may be performed instead for selected patients. The aim of the present work is to present the surgical method, including indications and technical information, as well as the presentation of the results in our recent patient collective.All patients semi-converted in our department of vascular surgery and phlebology due to (type II) endoleak were included. All data are presented as n (%) or median (range).Between 6/2019 and 3/2023, 13 patients underwent semi-conversion 6 (2-12) years (median, range) after the initial EVAR. The aneurysm sac diameter at the time of semi-conversion was 69 mm (58-95 mm), the operating time was 114 min (97-147 min), the blood loss was 100 ml (100-1500 ml). Five (38%) patients received blood transfusion intraoperatively and 2 (15%) postoperatively. The stay in the intensive care unit lasted 1 (1-5) days, the hospitalisation time was 8 (6-11) days. Postoperative complications were intestinal atony (3 [23%], 1 [8%] with nausea/emesis and gastric tube insertion), anaemia (2 [15%]), hyponatraemia (2 [15%]), delirium (1 [8%]), COVID-19 infection (1 [8%]) and 1 [8%] intra-abdominal postoperative bleeding with the indication for surgical revision and the transfusion of 8 erythrocyte concentrates.Semi-conversion is a safe and practicable surgical method with few severe complications for a selected group of patients, which should be considered as an alternative to more invasive methods with (partial) removal of the EVAR-prosthesis. Further long-term studies comparing semi-conversion to full conversion are needed to demonstrate its benefits.
Collapse
|
32
|
Mehmedovic A, Tsilimparis N, Stavroulakis K, Rantner B, Fernandez Prendes C, Gouveia E Melo R, Abicht JM, Stana J. Cervical Debranching: Regional versus General Anesthesia for Carotid-Subclavian Bypass. A Single Center Experience. Ann Vasc Surg 2023; 96:132-139. [PMID: 37085013 DOI: 10.1016/j.avsg.2023.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 03/27/2023] [Accepted: 04/01/2023] [Indexed: 04/23/2023]
Abstract
BACKGROUND We report here the first cohort study comparing regional and general anaesthesia for left subclavian artery (LSA) revascularization. METHODS A single-centre retrospective cohort study was performed, including all consecutive patients who underwent cervical debranching with carotid-subclavian bypass before aortic repair from February 2018 to May 2022. Patients were divided into 2 groups according to the type of anesthesia: Regional anesthesia (RA) versus general anesthesia (GA). Primary endpoints included the following: 1) technical success of RA and 2) neurological complications (NCs) (stroke and peripheral neurological lesions). Secondary endpoints included postoperative bleeding, wound complications, 30-day reintervention rate, and midterm events. RESULTS Eighty-three patients were included in the study. The mean age was 64 years (interquartile range [IQR]:13.5) and 69% were male. Thirty-seven patients (44.5%) were performed under RA. Technical success of RA was 89.2%. Two minor strokes (2.4%) were observed in the GA group (P = 0.199). Peripheral neurological disorders occurred in 4 patients (4.8%) (RA group n = 1 (2.7%), GA group n = 3 (6.5%), P = 0.491). 30-day complication rate was 27.7% (n = 23, GA: n = 15 (32.6%), RA: n = 8 (21.6%), P = 0.266). 30-day reintervention rate was 14.5% (n = 12) ten bleeding complications (12%) (RA group n = 3 (8.1%), GA group n = 7 (15.2%), P = 0.323), and 2 seroma evacuations (2.4%) in the RA group. The incidence of superficial wound infections was n = 6 (7.2%) (RA group n = 2 (5.4%), GA group n = 4 (8.7%), P = 0.565). Median follow-up time was 22 months (IQR 22 min/max 1-44). CONCLUSIONS In our cohort, RA for carotid subclavian bypass surgery proved to be a feasible and effective anesthetic procedure compared with GA.
Collapse
|
33
|
Prendes CF, Grab M, Stana J, Gouveia E Melo R, Mehmedovic A, Grefen L, Tsilimparis N. In vitro evaluation of the optimal degree of oversizing of thoracic endografts in prosthetic landing areas: a pilot study. J Vasc Surg Cases Innov Tech 2023; 9:101195. [PMID: 37496652 PMCID: PMC10366543 DOI: 10.1016/j.jvscit.2023.101195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 02/28/2023] [Indexed: 07/28/2023] Open
Abstract
Objective The optimal degree of proximal thoracic endograft oversizing when aiming for durable sealing in prosthetic grafts is unknown. The aim of the present study was to create an in vitro model for testing different oversized thoracic endografts in a reproducible and standardized manner and, subsequently, determine the optimal oversizing range when planning procedures with a proximal landing in prosthetic zones in the descending thoracic aorta or aortic arch. Methods An in vitro model consisting of a fixed 24-mm polyethylene terephthalate (Dacron; DuPont) graft sutured proximally and distally to two specifically designed 40-mm rings, with four force sensing resistors attached at four equally distant positions and a USB camera attached proximally for photographic and video documentation was used for deployment of Zenith TX2 (Cook Medical Inc) dissection platform endografts with diameters between 24 and 36 mm. After deployment, ballooning with a 32-mm compliant balloon was performed to simulate real-life conditions. The assessment of oversizing included visual inspection, calculation of the valley areas created between the prosthetic wall and the stent graft fabric, distance between the stent graft peaks, the radial force exerted by the proximal sealing stent, and the pull-out force necessary for endograft extraction. Results A total of 70 endografts were deployed with the oversizing ranging from 0% to 50%: 10 × 24 mm, 10 × 26 mm, 10 × 28 mm, 10 × 30 mm, 10 × 32 mm, 10 × 34 mm, and 10 × 36 mm. Two cases of infolding occurred with 50% oversizing. The valley areas increased from 8.79 ± 0.23 mm2 with 16.7% oversizing to 14.26 ± 0.45 mm2 with 50% oversizing (P < .001). A significant difference was found in the pull-out force required for endografts with <10% oversizing vs ≥10% oversizing (P < .001). The difference reached a plateau at ∼4 N with oversizing of >15%. The mean radial force of the proximal sealing stent was greater after remodeling with a compliant balloon (0.55 ± 0.02 N vs 0.60 ± 0.02 N after ballooning; P < .001). However, greater oversizing did not lead to an increase in the radial force exerted by the proximal sealing stent. Conclusions The findings from the present study offer additional insight into the mechanics of oversized stent grafts in surgical grafts. In endografts with the Zenith stent design (TX2), oversizing of <16.7% resulted in reduced resistance to displacement forces, and oversizing of >50% was associated with major infolding in 20% of cases. Long-term in vitro and in vivo testing is required to understand how these mechanical properties affect the clinical outcomes of oversizing.
Collapse
|
34
|
Peterss S, Stana J, Rantner B, Buech J, Radner C, Konstantinou N, Hagl C, Pichlmaier M, Tsilimparis N. Expert opinion: How to treat type IA endoleakage. Asian Cardiovasc Thorac Ann 2023; 31:604-614. [PMID: 36740844 DOI: 10.1177/02184923231154742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Type Ia endoleaks due to failed sealing or loss of landing zone and the adequate management thereof remain crucial for long-term therapeutic success following TEVAR. This expert opinion summarizes our institutional experience with endovascular, open surgical, and hybrid techniques in the context of recent scientific publications. The rapid turnover of technical innovations, but most importantly outcome data demonstrate the requirement for increasingly patient-tailored treatment strategies and the need for specialized aortic centers. The latter should offer a complete range of treatment options, an adequate perioperative management, and the highest level of multidisciplinary expertise.
Collapse
|
35
|
Melo RGE, Spath P, Stana J, Prendes CF, Stavroulakis K, Rantner B, Pichlmaier M, Tsilimparis N. Secondary Endovascular Conversions for Failed Open Repair. AORTA (STAMFORD, CONN.) 2023; 11:137-144. [PMID: 37949107 PMCID: PMC11038728 DOI: 10.1055/s-0043-1774724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 04/11/2023] [Indexed: 11/12/2023]
Abstract
Late aortic and graft-related complications after open aortic repair are not infrequent and a significant number of them are missed, diagnosed at a very late stage, or present as urgent complications such as aortic rupture or aorto-enteric fistula. Once a late complication is diagnosed and reintervention is necessary, both open and endovascular strategies are possible. Open reintervention is complex and usually associated with very high rates of morbidity and mortality. Endovascular techniques may offer several solutions for these cases, which may be tailored to the patient and specific complication. In this review, we aim to summarize current indications, options, and strategies for endovascular salvage after failed or complicated open surgical repair.
Collapse
|
36
|
Tsilimparis N, Bosiers M, Resch T, Torsello G, Austermann M, Rohlffs F, Coates B, Yeh C, Kölbel T. Two-year target vessel-related outcomes following use of off-the-shelf branched endografts for the treatment of thoracoabdominal aortic aneurysms. J Vasc Surg 2023; 78:289-298. [PMID: 37044318 DOI: 10.1016/j.jvs.2023.03.498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 03/08/2023] [Accepted: 03/09/2023] [Indexed: 04/14/2023]
Abstract
OBJECTIVE The aim of this study was to assess clinical outcomes and target vessel patency through 2 years following thoracoabdominal aortic aneurysms (TAAA) repair with the off-the-shelf Zenith t-Branch Thoracoabdominal Endovascular Graft (William Cook Europe). METHODS This post-market observational study was conducted at three European sites with ambispective enrollment from 2012 to 2017. Patients underwent endovascular TAAA repair with the t-Branch graft and bridging stent grafts (BSGs) for the celiac (CA), superior mesenteric (SMA), left renal (LRA), and/or right renal (RRA) arteries. Follow-up was through 2 years, per sites' standard of care. Procedural and 1-year results were reported previously. RESULTS Eighty patients (mean age, 71.0±7.4 years; 70.0% men) were enrolled; six patients had symptomatic TAAAs, and 15 patients had contained ruptures. Technical success was achieved in 98.8% of patients (79/80). Median follow-up was 22.2 months (interquartile range, 9.2-25.1 months). At 24 months, Kaplan-Meier (KM) freedom from all-cause and aneurysm-related mortality were 78.5% and 98.6%, respectively. Beyond 12 months, 38 adverse events occurred in 20 patients, including two aortic ruptures (one study aneurysm and one non-study aneurysm) and six deaths (none aneurysm-related, as reported by the site). Compared with postprocedure, maximum aneurysm diameter decreased (>5 mm) in 84.6% (44/52), remained unchanged in 3.8% (2/52), and increased (>5 mm) in 11.5% (6/52) of patients with imaging follow-up after 12 months. No conversions to open repair, and no t-Branch graft or other endograft component migration or integrity issues were reported. No loss of patency was reported in the t-Branch or iliac limb grafts throughout the study. Throughout study duration, four patients had five imaging-reported BSG compressions, none of which required secondary intervention. KM freedom from secondary intervention was 76.3% at 24 months. Fourteen target vessel-related secondary interventions were performed, primarily consisting of stent placement for endoleak, stenosis, or occlusion. KM freedom from loss of primary patency was 94.8%, 100%, 91.3%, and 89.3% for the CA, SMA, LRA, and RRA, respectively, at 24 months. KM freedom from loss of secondary patency in the CA, SMA, LRA, and RRA were 96.3%, 100%, 98.2%, and 98.3% at 24 months, respectively. A total of 298 vessels were targeted, of which 12 were occluded over the study period. CONCLUSIONS Primary and secondary target vessel patency rates through 2 years demonstrated durable repair with the t-Branch graft in patients treated for symptomatic or asymptomatic thoracoabdominal aortic aneurysms.
Collapse
|
37
|
Becker D, Ali A, Prendes C, Stavroulakis K, Stana J, Tsilimparis N. Physician Modification of a Custom-Made Fenestrated Endograft By Closure of a Fenestration With Bovine Patch. J Endovasc Ther 2023:15266028231187749. [PMID: 37464749 DOI: 10.1177/15266028231187749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/20/2023]
Abstract
PURPOSE Ruptured mycotic pararenal aortic aneurysms are rare and serious condition that requires prompt treatment. Open surgery with aortic resection and in-situ or extra-anatomic reconstruction is the standard treatment. The aim of this technical note is to report urgent endovascular treatment using a readily available custom-made device (created for another patient), with a back-table modification using pericardium patch and a new fenestration. TECHNIQUE In preoperative measurements on centerline-based workstation, aortic diameter in proximal and distal landing zone and target vessel position matched the measurements of graft plan of custom-made device (CMD) besides left renal artery. To address current patient`s anatomy, closure of the nonsuitable fenestration with pericardial patch and creation of new fenestration (1 cm above and 1:15 hours posterior to original fenestration) for the respective target vessel have been performed. Postoperative computed tomography angiography (CTA) scan showed complete exclusion of aneurysm, perfused target vessels, and no endoleak. Under resistance-based antibiotic therapy, the patient was asymptomatic and showed normal infection parameters in blood samples postoperatively. CONCLUSION In the hands of an experienced endovascular aortic surgeon modification of a custom-made device is a quick and feasible technique in this emergency situation. Long-term follow-up must confirm the durability and reliability of this new technique. CLINICAL IMPACT The described technique of modification of a custom-made endograft can provide an alternative endovascular treatment option for urgent complex abdominal aortic pathologies. Compared to the current available treatment modalities, like physician modified endografts, off-the-shelf branched devices, parallel grafts and in-situ fenestration, it can save considerable time and provides reasonable sealing in ruptured cases. The technique offers a valuable add-on to the armamentarium of experienced endovascular physicians.
Collapse
|
38
|
Eleshra A, Haulon S, Bertoglio L, Lindsay T, Rohlffs F, Dias N, Tsilimparis N, Panuccio G, Kölbel T. Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience. Eur J Vasc Endovasc Surg 2023; 66:50-56. [PMID: 36958480 DOI: 10.1016/j.ejvs.2023.03.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 02/26/2023] [Accepted: 03/13/2023] [Indexed: 03/25/2023]
Abstract
OBJECTIVE To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. METHODS A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. RESULTS A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 - 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 - 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. CONCLUSION This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique.
Collapse
|
39
|
Öz T, Rantner B, Stana J, Stavroulakis K, Peterß S, Pichlmaier M, Fernandez Prendes C, Tsilimparis N. [Malperfusion after Aortic Dissection - Management and Techniques]. Zentralbl Chir 2023. [PMID: 37327818 DOI: 10.1055/a-2058-9080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Malperfusion is a common complication of aortic dissection and further increases this deadly disease's mortality. An effective treatment strategy requires a timely diagnosis based on the clinical findings and the available instruments, understanding the disease's pathomechanism, recognising the therapy options recommended by the guidelines, and the diagnostic and therapeutic innovations of the area of research. The final treatment decision should be patient- and case-specific. In this work, we have considered malperfusion after aortic dissection, not only as a complication of aortic dissection but as a separate disease and summarise important information that can contribute to efficient therapy decisions in everyday clinical practice.
Collapse
|
40
|
Gouveia E Melo R, Fernández Prendes C, Khanafer A, Wanhainen A, Mani K, Rouhani G, Chao V, Tay KH, Chong TT, Adam D, Dias N, Agaev A, Tsilimparis N. Common Designs of Custom-Made Fenestrated Arch Devices and Applicability of an Off-the-Shelf Design. J Endovasc Ther 2023:15266028231179593. [PMID: 37300282 DOI: 10.1177/15266028231179593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
OBJECTIVES To analyze device designs, similarities and overlaps of custom-made fenestrated arch endografts intended for mid/distal arch thoracic endovascular aortic repair. MATERIALS AND METHODS A multicenter cross-sectional study analyzing custom-made anonymized graft plans was performed. Graft plans were included from a cohort of mid/distal aortic arch repairs using custom-made fenestrated aortic endografts treated at 8 centers. Grafts targeting >2 arteries were excluded. No patient/clinical data were analyzed. A descriptive analysis was performed followed by an analysis of overlap of the designs to reach a common design in which the greatest number of grafts would overlap. RESULTS One hundred thirty-one graft plans were included. All grafts were custom-made grafts from the COOK Medical Fenestrated arch platform. Ninety-four (71.8%) had a scallop-and-single-fenestration design, 33 (25.2%) had a single fenestration and 4 (4.3%) a single scallop. For analysis purposes, these latter 4 grafts were excluded. Two main graft plans (Plans 1 and 2) were proposed after analysis with similar configuration (1 scallop with 30 mm width, 20 mm height, 12:00 position; 1 preloaded fenestration with 8 mm diameter, 26 mm from the top of the graft and 12:00 position; tapered, with a 193 mm length and 32 mm distal diameter) but with 2 different proximal diameters of 38 mm (Plan 1) and 44 mm (Plan 2), reaching an overall feasibility of 85.8% (n=109), being 47.2% (n=60) and 38.6% (n=49) for each design, respectively. CONCLUSION The degree of overlap between the studied fenestrated and/or scalloped thoracic endovascular aneurysm repair (TEVAR) graft designs was high. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility. CLINICAL IMPACT In a multicenter study analyzing 127 fenestrated aortic arch endograft plans from 9 aortic centers, we found that the degree of overlap between the studied fenestrated and/or scalloped arch graft designs was high and that 2 proposed graft designs would be theoretically applicable in 85.8% of cases. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility.
Collapse
|
41
|
Konstantinou N, Dammer F, Bisdas T, Tsilimparis N, Stana J, Essa M, Stavroulakis K. Hybrid and open repair for patients with acute limb ischemia of the lower extremities. THE JOURNAL OF CARDIOVASCULAR SURGERY 2023; 64:255-261. [PMID: 37260153 DOI: 10.23736/s0021-9509.23.12672-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
BACKGROUND Hybrid revascularization procedures for acute limb ischemia (ALI) are becoming increasingly common, bibliographic data on outcomes is however sparse. METHODS Single-center, retrospective study of consecutive patients with ALI that underwent either surgical treatment (ST) or hybrid treatment (HT) between January 2015 and December 2021. The composite outcome of amputation-free survival (AFS) was the primary endpoint. Technical success, overall survival, amputation, and re-intervention rates were the secondary endpoints. RESULTS During the study period 266 patients (mean age 70.2±14.5 years; 49.6% males) were treated for ALI, 67.3% undergoing ST and 32.7% HT. HT was more frequently used in patients with a previous vascular intervention in the index limb (38/87; 43.7% HT vs. 40/179; 22.3% ST, P=0.001), a stent- or stent graft-occlusion (16/87; 18.4% HT vs. 10/179; 5.6% ST, P=0.002) and/or a bypass occlusion (16/87; 18.4% HT vs. 16/179; 8.9% ST, P=0.043). Technical success was higher in the OR group (75/87; 86.2% HT vs. 173/179; 96.6% ST, P=0.003). Amputation-free survival rate during follow-up (43/87; 49.4% HT vs. 94/179; 52.5% ST, HR 0.76, 95% CI: 0.49 to 1.18, P=0.22) and overall survival (32/87; 36.8% HT vs. 84/179; 46.9% ST, HR 0.81, 95% CI: 0.49 to 1.34, P=0.41) were comparable between the two groups. No statistical differences were observed between the groups regarding major amputation (19/87; 21.8% HT vs. 15/179; 8.4% ST, HR 0.85, 95% CI: 0.33 to 2.23, P=0.74) or reintervention during follow-up (45/87; 51.7% HT vs. 65/179; 36.3% ST, HR 0.92, 95% CI: 0.56 to 1.51, P=0.73). CONCLUSIONS Hybrid and open surgical treatments showed comparable results in our cohort, even though significantly more patients undergoing HT presented with stent and bypass occlusions rather than de-novo lesions.
Collapse
|
42
|
Spath P, Cardona-Gloria Y, Torsello G, Gallitto E, Öz T, Beropoulis E, Stana J, Gargiulo M, Tsilimparis N. Use of Secondary Iliac Branch Devices after Previous Endovascular Abdominal and Thoraco-Abdominal Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg 2023; 65:819-826. [PMID: 36707020 DOI: 10.1016/j.ejvs.2023.01.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 11/20/2022] [Accepted: 01/19/2023] [Indexed: 01/26/2023]
Abstract
OBJECTIVE To assess the safety and effectiveness of iliac branch devices (IBDs), as secondary procedure, for the treatment of type Ib endoleak or evolution of iliac artery disease after prior endovascular aortic repair (EVAR) for thoraco-abdominal (TAAAs) or abdominal aortic aneurysms (AAAs). METHODS A multicentre observational study of three European centres. The study included 75 patients (age 71 ± 9 years, 96% men) with previous EVAR (n = 64, 85%) or fenestrated or branched (FB) EVAR (n = 11, 15%). Overall, 88 IBDs were implanted to treat aneurysmal iliac artery evolution in 40 (53%) and type Ib endoleak in 35 (47%) cases, respectively. Thirteen (17%) patients received bilateral IBDs. Internal iliac artery (IIA) catheterisation was done through a transaxillary access (n = 82, 93%) or up and over (n = 6, 7%) technique. The primary endpoint was technical success. Secondary endpoints were 30 day major adverse event, early and long term freedom from re-intervention and target vessel instability. RESULTS All procedures were technically successful (100%). During hospitalisation, there were four (5%) major adverse events and three (4%) early re-interventions, but no death, stroke, or damage to previous endografts. The median follow up was 47 (interquartile range 42) months, and the five year survival rate was 78 ± 6% with no aortic related death. Cox's regression analysis showed pre-operative renal function impairment (hazard ratio [HR] 3.4; 95% confidence interval [CI] 1.1 - 10.1; p = .033), and primary TAAA repair (HR 6.1; 95% CI 1.6-22.3; p = .006) as independent factors for long term mortality. Freedom from re-interventions was 85 ± 4% at five years with 11 (12%) cases (five endoleaks, four IBD thromboses, two stenoses). IIA instability was reported in three (3%) limbs and freedom from IIA instability was 95 ± 3% after 60 months. CONCLUSION Secondary IBD after EVAR is a safe and effective procedure with high technical success and low complication rates. The technique of choice to revascularise the IIA seems not to affect early and follow up results. Long term durability of IBD repair is acceptable with low rates of IIA re-intervention.
Collapse
|
43
|
Schachner T, Gottardi R, Schmidli J, Wyss TR, Van Den Berg JC, Tsilimparis N, Bavaria J, Bertoglio L, Martens A, Czerny M. Practice of neuromonitoring in open and endovascular thoracoabdominal aortic repair-an international expert-based modified Delphi consensus study. Eur J Cardiothorac Surg 2023; 63:ezad198. [PMID: 37252816 DOI: 10.1093/ejcts/ezad198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 04/21/2023] [Accepted: 05/12/2023] [Indexed: 06/01/2023] Open
Abstract
OBJECTIVES Spinal cord injury is detrimental for patients undergoing open or endovascular thoracoabdominal aortic aneurysm (TAAA) repair. The aim of this survey and of the modified Delphi consensus was to gather information on current practices and standards in neuroprotection in patients undergoing open and endovascular TAAA. METHODS The Aortic Association conducted an international online survey on neuromonitoring in open and endovascular TAAA repair. In a first round an expert panel put together a survey on different aspects of neuromonitoring. Based on the answers from the first round of the survey, 18 Delphi consensus questions were formulated. RESULTS A total of 56 physicians completed the survey. Of these, 45 perform open and endovascular TAAA repair, 3 do open TAAA repair and 8 do endovascular TAAA repair. At least 1 neuromonitoring or protection modality is utilized during open TAAA surgery. Cerebrospinal fluid (CSF) drainage was used in 97.9%, near infrared spectroscopy in 70.8% and motor evoked potentials or somatosensory evoked potentials in 60.4%. Three of 53 centres do not utilize any form of neuromonitoring or protection during endovascular TAAA repair: 92.5% use CSF drainage; 35.8%, cerebral or paravertebral near infrared spectroscopy; and 24.5% motor evoked potentials or somatosensory evoked potentials. The utilization of CSF drainage and neuromonitoring varies depending on the extent of the TAAA repair. CONCLUSIONS The results of this survey and of the Delphi consensus show that there is broad consensus on the importance of protecting the spinal cord to avoid spinal cord injury in patients undergoing open TAAA repair. Those measures are less frequently utilized in patients undergoing endovascular TAAA repair but should be considered, especially in patients who require extensive coverage of the thoracoabdominal aorta.
Collapse
|
44
|
Prendes CF, Spath P, Stana J, Hamwi T, Peterss S, Stavroulakis K, Pichlmaier M, Tsilimparis N. Transaxillary Branch-to-Branch-to-Branch Carotid Catheterization Technique for Triple-Branch Arch Repair. J Endovasc Ther 2023:15266028231169169. [PMID: 37222497 DOI: 10.1177/15266028231169169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
PURPOSE To describe the transaxillary branch-to-branch-to-branch carotid catheterization technique (tranaxillary 3BRA-CCE IT) for cannulation of all supra-aortic vessels using only 1 femoral and 1 axillary access during triple-branch arch repair. TECHNIQUE After deployment of the triple-branch arch device, catheterization and bridging of the innominate artery (IA) should be performed through a right axillary access (cutdown or percutaneous). Then, the retrograde left subclavian (LSA) branch should be catheterized (if not preloaded) from a percutaneous femoral access, and a 12×90Fr sheath should be advanced to the outside of the endograft. Subsequently, catheterization of the left common carotid artery (LCCA) antegrade branch should be performed, followed by snaring of a wire in the ascending aorta which was inserted through the axillary access, creating a branch-to-branch-to-branch through-and-through guidewire. Over the axillary access, a 12×45Fr sheath should be inserted into the IA branch and looped in the ascending aorta using a push-and-pull technique so that it faces the LCCA branch, allowing for stable catheterization of the LCCA. The retrograde LSA branch should then be bridged following the standard fashion. CONCLUSIONS This series of 5 patients demonstrates that triple-branch arch repair can be performed with the transaxillary 3BRA-CCE IT, allowing catheterization of the supra-aortic vessels without manipulation of the carotid arteries. CLINICAL IMPACT The transaxillary 3BRA-CCE IT allows catheterization and bridging of all supra-aortic vessels in triple-branch arch repair through only 2 vascular access points, the femoral artery and the right axillary artery. This technique avoids carotid surgical cutdown and manipulation during these procedures, reducing the risk of access site complications, including bleeding and reintervention, reintubation, cranial nerve lesions, increased operating time, and so on, and has the potential to change the current vascular access standard used during triple-branch arch repair.
Collapse
|
45
|
Stavroulakis K, Tsilimparis N, Saratzis A, Rantner B, Stana J, Dayama A, Davies MG, Gouveia E Melo R. Acute Kidney Injury Following Revascularization in Patients With Chronic Limb-Threatening Ischemia and Non-Dialysis-Dependent Chronic Kidney Disease: Insights From the NSQIP Database at 30-Day Follow-Up. J Endovasc Ther 2023:15266028231173297. [PMID: 37191239 DOI: 10.1177/15266028231173297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
BACKGROUND Patients with chronic limb-threatening ischemia (CLTI) and chronic kidney disease (CKD) are at risk of developing renal injury following revascularization. We aimed to compare the risk of adverse renal events following endovascular revascularization (ER) or open surgery (OS) in patients with CLTI and CKD. METHODS A retrospective analysis of the National Surgical Quality Improvement Program (NSQIP) databases (2011-2017) was performed including patients with CLTI and non-dialysis-dependent CKD, comparing ER to OS. The primary outcome was a composite of postprocedural kidney injury or failure within 30 days. Thirty-day mortality, major adverse cardiac and cerebrovascular events (MACCE), amputation, readmission or target lesion revascularization (TLR) were compared using multivariate logistic regression and propensity-score matched analysis. RESULTS A total of 5009 patients were included (ER: 2361; OS: 3409). The risk for the composite primary outcome was comparable between groups (odds ratio [OR]: 0.78, 95% confidence interval (CI): 0.53-1.17) as for kidney injury (n=54, OR: 0.97, 95% CI: 0.39-1.19) or failure (n=55, OR: 0.68, 95% CI: 0.39-1.19). In the adjusted regression, a significant benefit was observed with ER for the primary outcome (OR: 0.60, p=0.018) and renal failure (OR: 0.50, p=0.025), but not for renal injury (OR: 0.76, p=0.34). Lower rates of MACCE, TLR, and readmissions were observed after ER. Thirty-day mortality and major amputation rates did not differ. In the propensity score analysis, revascularization strategy was not associated with renal injury or failure. CONCLUSIONS In this cohort, the incidence of renal events within 30 days of revascularization in CLTI was low and comparable between ER and OR. CLINICAL IMPACT In a cohort of 5009 patients with chronic limb-threatening ischemia and non-end-stage chronic kidney disease (CKD), postprocedural kidney injury or failure within 30 days was comparable between patients submitted to open or endovascular revascularization (ER). Lower rates of major adverse cardiac and cerebrovascular events, target lesion revascularization, and readmissions were observed after endovascular revascularization. Based on these findings, ER should not be avoided due to fear of worsening renal function in CKD patients with chronic limb-threatening ischemia. In fact, these patients benefit more from ER regarding cardiovascular outcomes with no increased risk of kidney injury.
Collapse
|
46
|
Spath P, Tsilimparis N, Furlan F, Hamwi T, Prendes CF, Stana J. Additional Aortic Coverage With an Off The Shelf, Multibranched Endograft Compared With Custom Made Devices For Endovascular Repair of Pararenal Abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg 2023; 65:710-718. [PMID: 36707021 DOI: 10.1016/j.ejvs.2023.01.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 10/07/2022] [Accepted: 01/16/2023] [Indexed: 01/26/2023]
Abstract
OBJECTIVE Pararenal abdominal aortic aneurysms (p-AAA) require complex endovascular aortic repair or open surgical repair with suprarenal clamping. Custom made devices (CMD), including fenestrated and branched endovascular aortic repair (F/B-EVAR) or off the shelf (OTS) multibranched devices, are available treatment options. The aim of this study was to determine the additional healthy aortic coverage using an OTS multibranched endograft vs. a CMD for the treatment of p-AAAs. METHODS This was a retrospective single centre analysis of prospectively collected data. Consecutive patients with p-AAAs requiring a proximal landing zone above the coeliac artery (CA), planned and treated with CMDs (Zenith Fenestrated) between January 2017 and December 2021 were included in this study. Treatment with supracoeliac coverage using available OTS multibranched devices was simulated using available pre-operative images: T-Branch; E-nside; and TAMBE. Study endpoints included the need for additional proximal aortic coverage, and the number of the segmental arteries additionally covered proximally from the CA for OTS devices compared with CMDs. RESULTS Eighty three patients with p-AAAs were treated with CMDs (all FEVAR), including juxtarenal AAAs (n = 46; 56%), suprarenal AAAs (n = 20; 24%), and short neck AAAs (n = 17; 20%). In this study, treatment with 249 (3 × 83) OTS endografts was simulated. When compared with CMDs, OTS devices required a mean of 74 ± 19 mm of additional proximal healthy aortic coverage from the CA (CMD: 33 ± 19 mm vs. OTS: 108 ± 6 mm; p ≤ .001), as well as an average sacrifice of 2.5 additional segmental arteries (CMD: 1.3 ± 0.8 vs. OTS: 3.8 ± 0.9; p ≤ .001). In 94% of patients, at least one of the available multibranched endografts could have been implanted in accordance with instructions for use. CONCLUSION Despite not requiring customisation time, OTS endografts for the treatment of p-AAA lead to more extensive healthy aortic coverage, as well as an average sacrifice of 2.5 additional segmental arteries, compared with CMDs. When compared with OTS devices, CMDs appear to limit the extent of unnecessary aortic coverage and the theoretical subsequent risk of spinal cord ischaemia.
Collapse
|
47
|
Stavroulakis K, Torsello G, Chlouverakis G, Bisdas T, Damerau S, Tsilimparis N, Argyriou A. Intravascular Lithotripsy and Drug-Coated Balloon Angioplasty for Severely Calcified Common Femoral Artery Atherosclerotic Disease. J Endovasc Ther 2023:15266028231158313. [PMID: 36896876 DOI: 10.1177/15266028231158313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
OBJECTIVES Intravascular lithotripsy (IVL) followed by drug-coated balloon (DCB) angioplasty might be a valuable alternative to surgery for calcified common femoral artery (CFA) atherosclerotic disease. Nonetheless, the 12 months performance of this treatment strategy remains unknown. This study reports on the 12 months outcomes of IVL with adjunctive DCB angioplasty for calcified CFA lesions. METHODS This is a retrospective single-center, single-arm study. Consecutive patients treated by IVL and DCB for calcified CFA disease between February 2017 and September 2020 were evaluated. The primary measure outcome of this analysis was primary patency. Procedural technical success (<30% stenosis), freedom from target lesion revascularization (TLR), secondary patency, and overall mortality were additionally analyzed. RESULTS Thirty-three (n=33) patients were included in this study. The majority presented with lifestyle limiting claudication (n=20, 61%), 52% (n=17) of the patients had chronic kidney disease (CKD) and 33% (n=11) had diabetes. The procedural technical success was 97% (n=32). A flow-limiting dissection post IVL was observed in 2 patients (6%) and a peripheral embolization in a single patient (3%), while the bail-out stenting rate amounted to 12% (n=4). No perforation was observed. The median length of hospital stay was 2 days (interquartile range 2-3). At 12 months, the primary patency was 72%. The freedom from TLR and the secondary patency rates were 94% and 88%, respectively. The 12-month survival amounted to 100% and 75% (n=25) of the patients were asymptomatic or presented with mild claudication. The presence of chronic limb-threatening ischemia (CLTI) (hazard ratio [HR], 0.92; confidence interval (CI); 0.18-4.8, p=0.7) or CKD (HR, 1.30; 95% CI, 0.29-5.8; p=0.72), as well as the use of a 7 mm IVL catheter (HR, 0.59; 95% CI, 0.13-2.63; p=0.49) or of high-dose DCB (HR, 0.68; 95% CI, 0.13-3.53; p=0.65) did not influence the primary patency. CONCLUSIONS In this study, the combination of IVL and DCB angioplasty for calcified CFA disease was associated with low risk for periprocedural complications, acceptable 12 months clinical outcomes, and low rates of reinterventions. CLINICAL IMPACT Intravascular lithotripsy in combination with DCB angioplasty can be an alternative to surgery in highly selected patients with CFA atherosclerotic disease. In this Cohort the combination therapy lead to acceptable clinical results and low reintervention rates at 12 months.
Collapse
|
48
|
Eleshra A, Oderich GS, McWilliams RG, Panuccio G, Katsargyris A, Tsilimparis N, Tenorio ER, Fisher RK, Verhoeven E, Kölbel T. Endovascular Preservation of Segmental Arteries During Treatment of Thoracoabdominal Aortic Aneurysm with Fenestrated/Branched Stent-Grafts: Feasibility and outcome. J Vasc Interv Radiol 2023:S1051-0443(23)00201-4. [PMID: 36889436 DOI: 10.1016/j.jvir.2023.02.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 02/19/2023] [Accepted: 02/26/2023] [Indexed: 03/08/2023] Open
Abstract
OBJECTIVES To evaluate technical success, feasibility, and outcomes of endovascular preservation of segmental arteries (SAs) during fenestrated /branched endovascular aortic repair (F/B-EVAR). METHODS A multicenter, retrospective study was conducted on consecutive patients treated with F/B-EVAR and a branch or fenestration for SA preservation. Eleven patients (median age 57, range 45-73; 7 men) were included. RESULTS Twelve SAs were preserved. Stent-grafts were custom-made with fenestrations, branches, or a combination of both in 1, 2, and 5 patients. A t-branch was used in 2 patients and physician-modified thoracic stent-graft with a branch was used in 1 patient. Eight branches and 4 fenestrations were used for the preservation of 12 SAs. Four fenestrations and 1 branch for SAs were not bridged and were left for the perfusion of the corresponding SAs. Technical success was achieved in 10/11 (91%) patients. No early mortality occurred. Early morbidities included renal insufficiency without dialysis in 1 patient and partially delayed paraplegia in 1 patient. Pre-discharge computed tomography angiography (CTA) showed patency of all SAs. No early aortic-related re-interventions were required. The median follow-up was 30 (range 10-88) months. Late death occurred in 1 patient. Two SAs occluded in 1 patient with two un-stented fenestrations at 1-year follow-up CTA. This patient did not develop spinal cord ischemia (SCI). Other SAs remained patent during follow-up. One patient with type IIIc endoleak was treated by relining of bridging stents. CONCLUSION Endovascular preservation of SAs with F/B-EVAR for thoracoabdominal aortic aneurysm is feasible and safe in selected patients and may add to preventive measures for SCI.
Collapse
|
49
|
Mihály Z, Öz T, Fernandez Prendes C, Stana J, Tsilimparis N. [Diagnosis and Therapy of Abdominal Aortic Aneurysm]. MMW Fortschr Med 2023; 165:58-65. [PMID: 36961715 DOI: 10.1007/s15006-023-2312-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2023]
|
50
|
Boyle JR, Tsilimparis N, Van Herzeele I, Wanhainen A. Editor's Choice - Focused Update on Patients Treated with the Nellix EndoVascular Aneurysm Sealing (EVAS) System from the European Society for Vascular Surgery (ESVS) Abdominal Aortic Aneurysm Clinical Practice Guidelines. Eur J Vasc Endovasc Surg 2023; 65:320-322. [PMID: 36623763 DOI: 10.1016/j.ejvs.2022.12.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 12/11/2022] [Accepted: 12/28/2022] [Indexed: 01/09/2023]
Abstract
OBJECTIVE After alerts on EndoVascular Aneurysm Seal (EVAS) failure were raised, the European Society for Vascular Surgery (ESVS) Abdominal Aortic Aneurysm (AAA) Clinical Practice Guidelines Writing Committee (WC) initiated a task force with the aim to provide guidance on surveillance and management of patients with implanted EVAS devices. METHODS Based on a scoping review of risk for late serious aortic-related adverse events in patients treated with EVAS for AAA, the ESVS AAA Guidelines WC agreed on recommendations graded according to the European Society of Cardiology (ESC) grading system. RESULTS EVAS has a very high incidence of late endograft migration resulting in proximal type 1 endoleak with risk of rupture, requiring open conversion with device explantation. The reported mortality rate for elective explantation varies between 0% and 14%, while acute conversion for rupture has a very dismal prognosis with a 67 - 75% mortality rate. CONCLUSION It is recommended that all patients in whom a Nellix device has been implanted should be identified, properly informed, and enrolled in enhanced surveillance. If device failure is detected, early elective device explantation should be considered in surgically fit patients.
Collapse
|