26
|
Vass C, Findl O, Sycha T, Bauer P, Schmetterer L. Medical interventions for primary open angle glaucoma and ocular hypertension. THE COCHRANE DATABASE OF SYSTEMATIC REVIEWS 2004. [DOI: 10.1002/14651858.cd003167.pub2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
27
|
Polska E, Polak K, Luksch A, Fuchsjager-Mayrl G, Petternel V, Findl O, Schmetterer L. Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects. Br J Ophthalmol 2004; 88:533-7. [PMID: 15031172 PMCID: PMC1772102 DOI: 10.1136/bjo.2003.028480] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIMS/BACKGROUND To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. METHODS The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. RESULTS None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. CONCLUSIONS These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency.
Collapse
|
28
|
Bühl W, Findl O, Menapace R, Sacu S, Köppl C, Kriechbaum K, Wirtitsch M. Nachstarhemmende Wirkung einer scharfkantigen Acryl-Intraokularlinse: 3-Jahres-Ergebnisse. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
29
|
Rainer G, Menapace R, Richter-Müksch S, Sacu S, Bühl W, Findl O, Georgopoulos M. Postoperativer Augendruck nach Kleinschnittkataraktchirurgie mit primärer posterioren Kapsulorhexis. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
30
|
|
31
|
Kiss B, Kriechbaum K, Findl O, Sacu S, Bühl W, Georgopoulos M, Drexler W. Biometrie des vorderen Augenabschnitts mittels Teilkohärenz-Laserinterferometrie – Vergleich des Prototypen mit dem IOL Master Focus. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
32
|
Bühl W, Neumayer T, Georgopoulos M, Menapace R, Findl O. Kurz- und Langzeitbeobachtung der morphologischen Veränderungen von regeneratorischem Nachstar. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
33
|
Sacu S, Findl O. Beobachtung der Linsenkapsel-Intraokularlinsen Interaktion nach Kataraktchirurgie mittels OCT. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
34
|
Findl O, Sacu S, Menapace R, Bühl W. Einfluss von Kunstlinsen-Material und -Design auf die Kapselblattverbindung am Optikrand. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
35
|
Sacu S, Findl O, Menapace R, Bühl W, Rainer G, Wirtitsch M, Kriechbaum K, Köppl C. Vergleich des Nachstarverhaltens zweier Acryl-Intraokularlinsen mit unterschiedlichem Haptikdesign: Acrysof SA60AT vs. Acrysof MA60BM. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
36
|
Findl O, Bühl W, Menapace R, Sacu S. Einfluss des Optikmaterials auf den Nachstar bei scharfkantigen Kunstlinsen. Klin Monbl Augenheilkd 2004. [DOI: 10.1055/s-2004-820112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
37
|
Rainer G, Menapace R, Findl O, Sacu S, Schmid K, Petternel V, Kiss B, Georgopoulos M. Effect of a fixed dorzolamide\Ntimolol combination on intraocular pressure after small-incision cataract surgery with Viscoat. Am J Ophthalmol 2004. [DOI: 10.1016/j.ajo.2004.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
38
|
Sycha T, Vass C, Findl O, Bauer P, Groke I, Schmetterer L, Eichler H. Interventions for normal tension glaucoma. Cochrane Database Syst Rev 2003:CD002222. [PMID: 14583947 DOI: 10.1002/14651858.cd002222] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Normal tension glaucoma is a clinical condition in which the optic nerve is pathologically excavated and the visual field is disturbed. Nevertheless it has been assumed that intraocular pressure plays a role in the progression of visual field defects in this disease, but other, mainly vascular factors, have been discussed as well. OBJECTIVES The objective of this review is to assess the effects of medical and surgical treatments for normal tension glaucoma. SEARCH STRATEGY Trials were identified from the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group trials register), MEDLINE, EMBASE and BIOSIS Previews. Bibliographies of identified trials were searched to find additional trials. In addition, investigators and pharmaceutical companies were contacted. Date of last search: January 2001. SELECTION CRITERIA This review includes randomised controlled trials in which medical or surgical interventions were compared to no treatment, placebo or other treatment in people with normal tension glaucoma. Two reviewers independently assessed the full text copies of the possibly relevant trials. Trial quality was assessed according to the methods set out in Section 6 of the Cochrane Reviewers' Handbook (Clarke 2000). DATA COLLECTION AND ANALYSIS Data were extracted by two reviewers and results were compared for differences. Discrepancies were resolved by discussion. The heterogeneity of interventions, follow-up periods and outcomes did not allow for statistical combinations of the study results. MAIN RESULTS According to the selection criteria on visual field loss, eight studies were included in this review. Only three studies focussed on patient relevant outcomes. In one trial a beneficial effect of lowering intraocular pressure was found, but only if data were corrected for cataract development. In two small studies a beneficial effect on visual field loss of brovincamine, a calcium antagonist was reported. REVIEWER'S CONCLUSIONS In one study the effect of intraocular pressure lowering on visual field outcome was only significant when data were corrected for cataract development. The results for calcium antagonists are promising, but larger trials have to be performed. Studies that focussed on reduction of intraocular pressure or haemodynamic variables are not necessarily relevant for the outcome in people with normal tension glaucoma.
Collapse
|
39
|
Polak K, Polska E, Luksch A, Dorner G, Fuchsjäger-Mayrl G, Findl O, Eichler HG, Wolzt M, Schmetterer L. Choroidal blood flow and arterial blood pressure. Eye (Lond) 2003; 17:84-8. [PMID: 12579176 DOI: 10.1038/sj.eye.6700246] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Untreated hypertension is associated with ocular complications and is a risk factor for the development and progression of vascular ocular pathologies. We set out to investigate the association between systemic blood pressure and choroidal blood flow. METHODS All subjects were male non-smokers, who did not receive any medication and had normal or slightly elevated blood pressure (systolic blood pressure < or = 160 mmHg; diastolic blood pressure < or = 100 mmHg). The association between systemic blood pressure and fundus pulsation amplitude, a measure of pulsatile choroidal blood flow, was investigated in 318 volunteers. In addition, the association between systemic blood pressure and blood flow velocities in the posterior ciliary arteries supplying the choroid was investigated in these subjects. RESULTS Ocular fundus pulsation amplitude (r = 0.252; P < 0.001) and mean flow velocity in the posterior ciliary arteries (r = 0.346, P < 0.001) were significantly associated with mean arterial pressure. The correlation of ocular haemodynamic variables with systolic and diastolic blood pressure was in the same range. CONCLUSIONS Our data indicate a small, but significant increase in choroidal blood flow with increasing blood pressure.
Collapse
|
40
|
Polak K, Petternel V, Luksch A, Krohn J, Findl O, Polska E, Schmetterer L. Effect of endothelin and BQ123 on ocular blood flow parameters in healthy subjects. Invest Ophthalmol Vis Sci 2001; 42:2949-56. [PMID: 11687541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
Abstract
PURPOSE To characterize the role of the endothelin system in the blood flow control of the optic nerve head and of the choroid in humans. METHODS Two studies were performed in healthy subjects. Study 1 was a randomized, placebo-controlled, double-masked, balanced, two-way crossover design and study 2 a three way-way crossover design. In study 1 twelve healthy male subjects received endothelin (ET)-1 in stepwise increasing doses of 1.25, 2.5, and 5 ng/kg x min (each infusion step occurred over 20 minutes) coinfused with BQ123 (60 microg/kg x min) or placebo on two different study days. In study 2 twelve healthy male subjects received two doses of BQ123 (60 or 120 microg/kg x min over 60 minutes) or placebo on three different study days. Measurements of optic nerve head blood flow (ONHBF) and choroidal blood flow (ChBF) were performed with laser Doppler flowmetry in both studies. In study 2 mean flow velocity (MFV) of the ophthalmic artery was assessed with Doppler sonography. RESULTS In study 1, ET-1 significantly decreased ONHBF (-22.8% +/- 4.3% at 5 ng/kg x min, P = 0.003 versus baseline) and ChBF (-21.7% +/- 3.2% at 5 ng/kg x min, P = 0.0001 versus baseline). The effect of the highest administered dose of exogenous ET-1 on ONHBF was significantly attenuated (P = 0.04, ANOVA) by coinfusion of BQ123. Effects of exogenous ET-1 on blood flow (2.5 ng/kg x min ET-1 or higher) also were attenuated in the choroid by coinfusion of BQ123 (ChBF: P = 0.03, ANOVA). In study 2, both dosages of BQ123 significantly increased MFV in the ophthalmic artery (60 microg/kg x min, 12.5% +/- 7.3%; 120 microg/kg x min, 17.2% +/- 9.2%, versus baseline; P = 0.001), but did not change blood flow in the ONH or the choroid. CONCLUSIONS BQ123 antagonizes the effects of exogenously administered ET-1 on blood flow in the ONH and the choroid. The data indicate, however, that ET-1 does not substantially contribute to the regulation of basal vascular tone in these tissues.
Collapse
|
41
|
Rainer G, Kiss B, Dallinger S, Findl O, Georgopoulos M, Vass C, Menapace R, Polak K, Eichler HG, Wolzt M, Schmetterer L. A double masked placebo controlled study on the effect of nifedipine on optic nerve blood flow and visual field function in patients with open angle glaucoma. Br J Clin Pharmacol 2001; 52:210-2. [PMID: 11488781 PMCID: PMC2014529 DOI: 10.1046/j.0306-5251.2001.01432.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
AIMS To investigate whether nifedipine affects ocular perfusion or visual fields in open angle glaucoma patients. METHODS In a parallel group study nifedipine or placebo was administered for 3 months (n = 30). Ocular fundus pulsation amplitude (FPA), cup blood flow (Flowcup) and visual field mean deviation (MD) were measured. RESULTS Five patients receiving nifedipine discontinued due to adverse events. Nifedipine did not affect FPA [difference: 0.3 microm (95% CI -0.3,0.9); P = 0.70], Flowcup: [difference: -9 rel.units (95% CI -133,114); P = 0.99], or MD [difference: 0.2dB (95% CI -2.2,2.7); P = 0.51] vs placebo. CONCLUSIONS Systemic nifedipine is not well tolerated in glaucoma patients and exerts no effect on visual fields or ocular perfusion.
Collapse
|
42
|
Rainer G, Menapace R, Findl O, Petternel V, Kiss B, Georgopoulos M. Effect of topical brimonidine on intraocular pressure after small incision cataract surgery. J Cataract Refract Surg 2001; 27:1227-31. [PMID: 11524194 DOI: 10.1016/s0886-3350(01)00790-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To evaluate the effect of brimonidine 0.2% on intraocular pressure (IOP) after small incision cataract surgery. SETTING Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS This prospective randomized study comprised 80 eyes of 40 patients scheduled for small incision cataract surgery in both eyes. In each patient, 1 eye was randomly assigned to receive 1 drop of brimonidine 0.2% or no treatment (control) immediately after surgery. The fellow eye received the other assigned treatment. All patients had standardized surgery by the same surgeon with sodium hyaluronate 1%, a temporal 3.5 mm sutureless posterior limbal incision, phacoemulsification, and implantation of a foldable intraocular lens. The IOP was measured preoperatively as well as 6 and 20 to 24 hours and 1 week postoperatively. RESULTS Six hours after surgery, the mean increase in IOP was 4.7 mm Hg +/- 6.1 (SD) in the brimonidine group and 4.6 +/- 5.3 mm Hg in the control group. In each group, 17 eyes (43%) had an IOP increase of 5 mm Hg or more. Twenty to 24 hours after surgery, the mean increase in IOP was 1.5 +/- 4.2 mm Hg in the brimonidine group and 1.6 +/- 4.4 mm Hg in the control group. There were no statistically significant between-group differences at any measurement. CONCLUSIONS In both groups, IOP significantly increased 6 hours and 20 to 24 hours after small incision cataract surgery. Brimonidine 0.2% failed to reduce the IOP increase observed after small incision cataract surgery.
Collapse
|
43
|
Vass C, Findl O, Sycha T, Bauer P, Schmetterer L. Medical interventions for primary open angle glaucoma and ocular hypertension. Hippokratia 2001. [DOI: 10.1002/14651858.cd003167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
44
|
Rainer G, Menapace R, Findl O, Petternel V, Kiss B, Georgopoulos M. Intraindividual comparison of the effects of a fixed dorzolamide-timolol combination and latanoprost on intraocular pressure after small incision cataract surgery. J Cataract Refract Surg 2001; 27:706-10. [PMID: 11377900 DOI: 10.1016/s0886-3350(00)00706-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
To compare the effect of a fixed dorzolamide-timolol combination with that of latanoprost on intraocular pressure (IOP) after small incision cataract surgery. Department of Ophthalmology, University of Vienna, Vienna, Austria. This prospective randomized study comprised 60 eyes of 30 patients scheduled for small incision cataract surgery in both eyes. The patients were randomly assigned to receive 1 drop of a fixed dorzolamide-timolol combination or latanoprost immediately after cataract surgery in the first eye. The second eye received the other antiglaucomatous agent. Cataract surgery was performed under sodium hyaluronate 1% with a temporal 3.5 mm sutureless posterior limbal incision, phacoemulsification, and implantation of a foldable intraocular lens. The IOP was measured preoperatively as well as 6 and 20 to 24 hours and 1 week postoperatively. Six hours after surgery, the mean IOP decreased by -0.8 mm Hg +/- 3.2 (SD) (P =.184) in the dorzolamide-timolol group and increased by 3.6 mm Hg +/- 3.5 (P <.001) in the latanoprost group. Twenty to 24 hours after surgery, the mean IOP decreased by -2.8 +/- 2.4 mm Hg (P <.001) in the dorzolamide-timolol group and increased by 0.6 +/- 3.5 mm Hg (P =.353) in the latanoprost group. The differences between groups were significant at 6 hours (P <.001) and 20 to 24 hours (P <.001). The fixed dorzolamide-timolol combination was more effective than latanoprost in reducing IOP after small incision cataract surgery. Only the fixed dorzolamide-timolol combination prevented a postoperative IOP increase and occasional IOP spikes of 30 mm Hg or higher.
Collapse
|
45
|
Findl O, Drexler W, Menapace R, Heinzl H, Hitzenberger CK, Fercher AF. Improved prediction of intraocular lens power using partial coherence interferometry. J Cataract Refract Surg 2001; 27:861-7. [PMID: 11408132 DOI: 10.1016/s0886-3350(00)00699-4] [Citation(s) in RCA: 153] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the feasibility of using a new optical biometry technique, dual-beam partial coherence interferometry (PCI), to improve intraocular lens (IOL) power prediction in cataract surgery. SETTING Department of Ophthalmology, Vienna General Hospital, and Institute of Medical Physics, University of Vienna, Vienna, Austria. METHODS Preoperative axial length (AL) data obtained with PCI biometry and applanation ultrasound (US) biometry in 77 eyes of 51 patients was applied to 4 commonly used IOL power formulas. The refractive outcome and the mean absolute error (MAE) were calculated for each formula using both biometry methods. A linear multiple-regression model based on preoperative PCI biometry data was derived to predict the postoperative anterior chamber depth (ACD). The predictive power of this regression model was assessed by adding the predicted ACD to the SRK/T formula. Predicted residuals were calculated to evaluate the feasibility and stability of this modified IOL power formula. RESULTS Using PCI instead of US biometry significantly improved the refractive outcome with all 4 IOL power formulas. The Holladay I and SRK/T formulas yielded an MAE of 0.44 diopter (D) using PCI AL data and 0.56 D and 0.57 D, respectively, using US biometry data. The SRK/T formula combined with the PCI regression model for postoperative ACD prediction performed slightly better (MAE 0.42 D) than the conventional SRK/T formula alone. Predicted residuals revealed an MAE of 0.46 D, proving the predictive performance of the new formula. CONCLUSIONS Partial coherence interferometry biometry applied to several widely used IOL power formulas yielded significantly better IOL power prediction and therefore refractive outcome in cataract surgery than US biometry. Further improvement can be achieved by applying PCI to a modified SRK/T formula that predicts the postoperative ACD using PCI biometry data.
Collapse
|
46
|
Georgopoulos M, Menapace R, Findl O, Rainer G, Petternel V, Kiss B. Posterior continuous curvilinear capsulorhexis with hydrogel and silicone intraocular lens implantation: development of capsulorhexis size and capsule opacification. J Cataract Refract Surg 2001; 27:825-32. [PMID: 11408126 DOI: 10.1016/s0886-3350(00)00793-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE To evaluate the influence of primary posterior continuous curvilinear capsulorhexis (PCCC) on capsule opacification development and capsular bag changes within the first year after cataract surgery with 2 intraocular lenses (IOLs) of comparable design but different material. SETTING Department of Ophthalmology, University of Vienna, Medical School, Vienna, Austria. METHODS Thirty-seven patients with age-related cataract had bilateral small incision cataract surgery with a PCCC performed after capsular tension ring insertion. One eye was randomly assigned to receive a hydrogel IOL and the other eye, a silicone IOL. Standardized digital retroillumination photographs were taken 1 day, 1 week, and 1, 3, 6, and 12 months after surgery to evaluate changes in the dimensions of the anterior and posterior capsulorhexis opening area and the presence of anterior and posterior capsule opacification. RESULTS The area of the anterior continuous curvilinear capsulorhexis (ACCC) opening was significantly reduced during the first 6 postoperative months. The shrinkage was more pronounced (-25%) in the silicone IOL group than in the hydrogel IOL group. Ten percent of eyes with a silicone IOL had marked shrinkage of the ACCC. The area of the PCCC did not change in eyes with a hydrogel IOL but was larger (+20%) in eyes with a silicone IOL. Anterior ongrowth was observed in 60% in the hydrogel group and in no eye in the silicone group. Anterior capsule fibrosis was observed in 90% in the silicone group and in 20% in the hydrogel group. Total closure of the PCCC was not observed within the first year, but posterior ongrowth was observed in 40% in the hydrogel group and 10% in the silicone group. CONCLUSIONS Anterior capsulorhexis shrinkage with concomitant posterior capsulorhexis enlargement was observed in eyes with a silicone IOL. The hydrogel IOL induced more ongrowth on the anterior and posterior IOL surfaces, whereas the silicone IOL induced more anterior capsule fibrosis. Total closure of the PCCC was not observed within the first year after surgery.
Collapse
|
47
|
|
48
|
Findl O, Menapace R, Georgopoulos M, Kiss B, Petternel V, Rainer G. Morphological appearance and size of contact zones of piggyback intraocular lenses. J Cataract Refract Surg 2001; 27:219-23. [PMID: 11226785 DOI: 10.1016/s0886-3350(00)00608-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
PURPOSE To characterize the morphology, size, and change in size of the contact zone of piggyback intraocular lenses (IOLs) of different materials and optic designs. SETTING Department of Ophthalmology, Vienna General Hospital, Vienna, Austria. METHODS In a prospective study, 9 eyes of 7 patients received piggyback IOLs of the following materials: poly(methyl methacrylate) (PMMA), acrylic, hydrogel, and silicone. The contact zone between the anterior and posterior IOLs was photodocumented from 1 day to 1 year after surgery using specular microscopy. The contact zone area was measured. RESULTS A contact zone was present with all IOL materials studied. The area of contact, however, differed significantly. With PMMA IOLs, the contact zone was small and surrounded by Newton rings, indicating the tiny gap between the IOLs. With IOLs of soft material, such as silicone and hydrogel, it was larger than with PMMA IOLs and had a slightly irregular shape. With foldable acrylic IOLs, it was regular, round, and slightly larger than with the soft materials. The contact area enlarged primarily during the first 3 months after surgery. After 1 year, 2 eyes with acrylic piggyback IOLs had a membrane formation around the contact zone and 2 eyes developed Elschnig pearls between the IOLs. CONCLUSION In piggyback IOL eyes, the shape and size of the contact zone were strongly dependent on the IOL material and optic design. Contact area enlargement seemed to be induced by capsule shrinkage. Fibrous membrane formation around the contact zone and Elschnig pearl formation between the piggyback IOLs were long-term complications of this technique.
Collapse
|
49
|
Rainer G, Menapace R, Findl O, Kiss B, Petternel V, Georgopoulos M, Schneider B. Intraocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents. Br J Ophthalmol 2001; 85:139-42. [PMID: 11159474 PMCID: PMC1723830 DOI: 10.1136/bjo.85.2.139] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIM To evaluate the effects of the dispersive viscoelastic agents Ocucoat (hydroxypropyl methylcellulose 2%) and Viscoat (sodium chondroitin sulphate 4%-sodium hyaluronate 3%) on postoperative intraocular pressure (IOP) after bilateral small incision cataract surgery. METHODS This prospective, randomised study comprised 80 eyes of 40 consecutive patients with age related cataract in both eyes scheduled for bilateral small incision cataract surgery. The patients were randomly assigned to receive Ocucoat or Viscoat during cataract surgery of the first eye. The second eye was operated later and received the other viscoelastic agent. Cataract surgery was performed with a temporal 3.2 mm sutureless posterior limbal incision, phacoemulsification, and implantation of a foldable silicone intraocular lens. The IOP was measured preoperatively as well as 6 hours, 20-24 hours, and 1 week postoperatively. RESULTS At 6 hours after surgery the mean IOP increased by 4.6 (SD 5.1) mm Hg in the Ocucoat group (p<0.001) and by 8.6 (8.1) mm Hg in the Viscoat group (p<0.001). The increase was significantly higher in the Viscoat group than in the Ocucoat group (p=0.004). Intraocular pressure spikes of 30 mm Hg or more occurred in two eyes in the Ocucoat and in nine eyes in the Viscoat group (p=0.023); 20-24 hours and 1 week postoperatively the mean IOP was not statistically different. CONCLUSION These findings indicate that Viscoat causes a significantly higher IOP increase and significantly more IOP spikes than Ocucoat in the early period after small incision cataract surgery.
Collapse
|
50
|
Kiss B, Dallinger S, Polak K, Findl O, Eichler HG, Schmetterer L. Ocular hemodynamics during isometric exercise. Microvasc Res 2001; 61:1-13. [PMID: 11162191 DOI: 10.1006/mvre.2000.2269] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The autoregulatory capacity of the human retina is well documented, but the pressure-flow relationship of the human choroid is still a matter of controversy. Recent data, using laser Doppler flowmetry to measure choroidal blood flow, indicate that the choroid has some autoregulatory potential, whereas most data using other techniques for the assessment of choroidal hemodynamics indicate that the choroidal pressure-flow curve is linear. We used a new laser interferometric technique to characterize choroidal blood flow during isometric exercise. Twenty healthy subjects performed squatting for 6 min during normocapnia and during inhalation of 5% CO2 and 95% air. Ocular fundus pulsation amplitude, flow velocities in the ophthalmic artery, intraocular pressure, and systemic hemodynamics were measured in 2-min intervals. To gain information on choroidal blood flow fundus pulsation amplitude was corrected for changes in flow pulsatility using data from the ophthalmic artery and for changes in pulse rate. Ocular perfusion pressure was calculated from mean arterial pressure and intraocular pressure. The ocular pressure-flow relationship was calculated by sorting data according to ascending ocular perfusion pressure values. In a pilot study in 6 healthy subjects comparable ocular pressure flow relationships were obtained when choroidal blood flow was assessed with the method described above and with laser Doppler flowmetry. In the main study isometric exercise caused a significant increase in mean arterial pressure (56%, P < 0.001), pulse rate (84%, P < 0.001), and intraocular pressure (37%, P 0.004), but decreased fundus pulsation amplitude (-36%, P < 0.001). Significant deviations from baseline choroidal blood flow were observed only at ocular perfusion pressures >69% during normocapnia and 70% during hypercapnia. Our data indicate that during isometric exercise the choroid has a high capacity to keep blood flow constant despite changes in perfusion pressure and that this pressure-flow relationship is not altered by moderate changes in arterial carbon dioxide levels.
Collapse
|