26
|
Tari G, Molnar J, Ashton P. Examples of salt tectonics from West Africa: a comparative approach. ACTA ACUST UNITED AC 2003. [DOI: 10.1144/gsl.sp.2003.207.5] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AbstractExploration experience gained in specific salt basins of West Africa may not be directly applicable to other salt basins along the entire passive margin. To conduct a comparative structural analysis, regional reflection seismic transects were constructed across the salt basins of Morocco, Senegal, Guinea-Bissau, Equatorial Guinea, Gabon and Angola.Regional-scale similarities of the salt basins include the progressive complication of salt-related structures basinward, the change from an extensional domain on the shelf to a compressional domain on the slope and the presence of a toe-thrust front at the oceanward edge of the basins. Regional-scale differences are partly attributed to the relative stratigraphic position of the salt in relation to the rift history.In the better-known post-rift salt basins of Equatorial Guinea, Gabon, Congo and Angola updip extension is represented by a broad rafted domain balanced by downdip contraction in the form of salt tongues, canopies and a toe-thrust zone. The efficiency of this gravity sliding/spreading across the whole margin is due to the more or less uniform original distribution of Aptian salt in the post-rift succession forming a continuous detachment level.In contrast, the typically uneven original distribution of the Late Triassic and Early Jurassic syn-rift salt in Morocco, Mauritania, Senegal, The Gambia and Guinea-Bissau is due to basement highs separating rift half-grabens and creating a different structural pattern. Individual salt structures, such as pillows and diapirs, originated from isolated patches of the autochthonous salt. In the case of syn-rift salt, updip extension may not always be the ultimate driving force for the contractional salt-deformation downdip.
Collapse
|
27
|
Patchell RA, Regine WF, Ashton P, Tibbs PA, Wilson D, Shappley D, Young B. A phase I trial of continuously infused intratumoral bleomycin for the treatment of recurrent glioblastoma multiforme. J Neurooncol 2002; 60:37-42. [PMID: 12416544 DOI: 10.1023/a:1020291229317] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Intratumoral (IT) chemotherapy has theoretical advantages in the treatment of brain tumors. The blood-brain barrier is not a factor in drug delivery, and large concentrations of drug can be instilled in the tumor with little systemic toxicity. Bleomycin has activity against gliomas and is a cell cycle selective agent whose efficacy should be enhanced by continuous infusion. We performed a phase I trial to test the feasibility of IT chemotherapy using a refillable, sustained release device, and to determine the maximum tolerable dose of IT bleomycin. The study was an open-ended dose escalation study. A modified Ommaya reservoir (containing a semipermeable membrane) was implanted with the delivery tube in the center of the tumor. Groups of three patients with recurrent glioblastoma multiforme were entered at progressively higher dose levels of bleomycin. The study closed when all patients at a given starting dose level developed toxicity. Nine patients received doses ranging from 5 to 34 U/wk; the median total cumulative dose was 195 U. No dose limiting systemic toxicity was detected. Neurologic toxicity occurred only at doses above 16 U/wk. We conclude that continuously infused IT bleomycin is well tolerated; the MTD (and recommended dose for a phase II efficacy trial) of IT bleomycin is 16 U/wk.
Collapse
|
28
|
Gilger B, Malok E, Stewart T, Ashton P, Smith T, Jaffe G, Allen J. Long-term effect on the equine eye of an intravitreal device used for sustained release of cyclosporine A. Vet Ophthalmol 2001; 3:105-110. [PMID: 11397291 DOI: 10.1046/j.1463-5224.2000.00117.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE: To determine the long-term toxicity of an intravitreal device releasing continuous cyclosporinee A (CsA) in normal eyes of horses by evaluating clinical signs, electroretinography, and histopathology. Animals Studied Ten adult horses with normal ophthalmic examinations were used in this study Procedure(s) Four horses had one eye implanted with a CsA device, and six horses had the right eye implanted with a CsA-containing device (10 eyes with CsA in total) and the left eye (six eyes in total) with the device without drug (control). The implants were placed in the vitreous of the eyes through a sclerotomy 1 cm posterior to the limbus in the dorso-temporal quadrant of the eye. Scotopic electroretinograms were performed prior to implantation and at 1 week, and at 1, 3, 6, 9, and 12 months postimplantation. Two of the unilaterally implanted horses were euthanized at 1 weeks postimplantation, and two at 6 weeks postimplantation. Two of the bilaterally implanted horses were euthanized at 6 months, two at 9 months, and two at 12 months postimplantation. At euthanasia, the eyes were removed, aqueous and vitreous humor aspirated, and tissues fixed in 10% buffered formalin and processed for histopathology. CsA concentrations were measured by high pressure liquid chromatography in the aqueous and vitreous humors, and in peripheral blood. RESULTS: The devices were tolerated well in 14 of 16 eyes. There was minimal postoperative inflammation in most eyes, with a normal appearance within 7 days. In two eyes implanted with the CsA device, severe inflammation resulted in phthisis bulbi by 28 days. One of these eyes exhibited suspected bacterial endophthalmitis, and one had a sterile endophthalmitis and cataract presumably from trauma to the lens during implantation. In the other 14 eyes, no change was observed in the scotopic electroretinograms (ERG) from preoperative results, and no significant differences between the right (CsA) and left (control device) eyes were observed. CsA levels in the aqueous and vitreous humor, and peripheral blood were below the detection limit of the HPLC. Histologic findings revealed only a mild lymphoplasmacytic cellular infiltrate in the ciliary body and pars plana near the implantation site. CONCLUSIONS: The CsA devices were well tolerated with no long-term complications from the implants themselves. However, complications may occur from inadvertent implantation trauma or contamination during surgery. The long-term safety of the device may make it useful for delivery of CsA in the control of equine recurrent uveitis.
Collapse
|
29
|
Jaffe GJ, Pearson PA, Ashton P. Dexamethasone sustained drug delivery implant for the treatment of severe uveitis. Retina 2001; 20:402-3. [PMID: 10950421 DOI: 10.1097/00006982-200004000-00015] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
30
|
Perkins SL, Gallemore RP, Yang CH, Guo H, Ashton P, Jaffe GJ. Pharmacokinetics of the fluocinolone/5-fluorouracil codrug in the gas-filled eye. Retina 2001; 20:514-9. [PMID: 11039427 DOI: 10.1097/00006982-200009000-00013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine the effect of intraocular gas tamponade on drug levels achieved with the intravitreal sustained-release fluocinolone (FL)/5-fluorouracil (5-FU) codrug pellet. METHODS After insertion of a 10-mg codrug pellet into the right eyes of 43 New Zealand white rabbits, perfluoropropane (0.4 mL of 100% C3F8) or a control sham was then injected into the midvitreous cavity. On postoperative days 2, 4, 7, 21, and 42, aqueous samples were collected, the rabbits were killed, and the right eyes were enucleated. The vitreous and remaining codrug pellet were then isolated. Pellet and intravitreal drug levels were determined by high-pressure liquid chromatography. RESULTS No measurable drug levels were detected in any of the aqueous samples. Maximal gas expansion occurred by day 4 and partial resorption was observed by days 14 to 21. Vitreous FL and 5-FU levels during C3F8 expansion (day 2) were statistically significantly higher in the gas-filled eyes. On postoperative days 4, 7, 21, and 42, there were no statistically significant differences between FL and 5-FU drug levels in eyes containing C3F8 as compared with control eyes. Pellet codrug, FL, and 5-FU levels over time were similar in gas-filled and control eyes. CONCLUSIONS Intraocular gas tamponade does not significantly affect the sustained intravitreal drug levels achieved with the FL/5-FU codrug. If clinically efficacious, the FL/5-FU codrug formulation does not need to be altered to treat proliferative vitreoretinopathy in the presence of intraocular gas.
Collapse
|
31
|
Jaffe GJ, Ben-Nun J, Guo H, Dunn JP, Ashton P. Fluocinolone acetonide sustained drug delivery device to treat severe uveitis. Ophthalmology 2000; 107:2024-33. [PMID: 11054326 DOI: 10.1016/s0161-6420(00)00466-8] [Citation(s) in RCA: 160] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE Uveitis is often a chronic disease requiring long-term medical therapy. In this report, we describe a pilot safety and efficacy trial of a novel sustained drug delivery system containing fluocinolone acetonide to treat patients with severe uveitis. DESIGN Prospective, noncomparative, interventional case series PARTICIPANTS Patients with severe uveitis. METHODS Sustained drug delivery devices designed to release fluocinolone acetonide for at least 2.5 years were implanted through the pars plana into the vitreous cavity of seven eyes of five patients. All patients had severe uveitis not well controlled with, or intolerant to, repeated periocular corticosteroid injections, systemic corticosteroids, nonsteroidal immunosuppressive agents, or a combination thereof at the time of device implantation. Before device implantation, patients underwent complete evaluation including history, ophthalmologic examination, fluorescein angiography, visual field testing, and electroretinography. After surgery, patients were reexamined at 1 week, 2 weeks, 4 weeks, and at 1- to 3-month intervals. Visual fields, electroretinograms, and fluorescein angiography were repeated at 3- to 6-month intervals. MAIN OUTCOME MEASURES Preoperative and postoperative visual acuity, ocular inflammation, anti-inflammatory medication use, and intraocular pressure. RESULTS Patients had a diagnosis of Behçet's syndrome (two eyes), or idiopathic panuveitis (five eyes, including two with necrotizing retinitis, two with progressive chorioretinitis, and one with iridocyclitis and intermediate uveitis). Patients were observed an average of 10 months (range, 5-19 months). All eyes had stabilized or improved visual acuity after device implantation, and four of seven eyes had an improvement of three lines or more. The mean initial visual acuity, measured by Snellen chart, was 20/207, and the mean final visual acuity was 20/57 (P = 0.02). After surgery, at the final visit, no eye had clinically detectable inflammation, and all seven eyes had a marked reduction in systemic, topical, and periocular anti-inflammatory medication use. Four eyes had increased intraocular pressure 6 weeks to 6 months after device implantation. Intraocular pressure has been controlled on topical medications. No patient experienced intraoperative complications. CONCLUSIONS A fluocinolone acetonide sustained drug delivery device is a promising new therapy for the treatment of severe uveitis. Intraocular pressure must be carefully monitored long after device implantation. Based on these data, a randomized study of a larger group of patients is warranted.
Collapse
|
32
|
Gilger BC, Malok E, Stewart T, Horohov D, Ashton P, Smith T, Jaffe GJ, Allen JB. Effect of an intravitreal cyclosporine implant on experimental uveitis in horses. Vet Immunol Immunopathol 2000; 76:239-55. [PMID: 11044557 DOI: 10.1016/s0165-2427(00)00219-1] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The purpose of this study was to determine the effects of an intravitreal device releasing cyclosporine A (CsA) on recurrent inflammatory episodes in experimental uveitis. Nine normal horses were immunized peripherally with H37RA-mTB antigen twice, and then received 25 microg of H37RA-mTB antigen intravitreally in the right eye and an equal volume of balanced salt solution intravitreally in the left eye. Two weeks later, the animals randomly received either a CsA or a polymer implant (without CsA) in both eyes 1 week following implantation of the devices, 25 microg of H37RA-mTB antigen was reinjected into the right eye of each animal. Clinical signs of ophthalmic inflammation were graded following injections and implantation. The animals from each group were euthanized at 3, 14, and 28 days following the second injection. Aqueous and vitreous humor protein concentrations were measured. The presence, number, and type (CD4, 5 and 8) of infiltrating inflammatory cells and amount of tissue destruction were determined. Total RNA was isolated and quantitative reverse transcriptase-polymerase chain reaction was performed for equine specific interleukin (IL) 2 and 4, interferon-gamma (IFN gamma) and beta-actin. In addition, aqueous and vitreous humor and peripheral blood were collected at the termination of the experiments and analyzed for CsA concentration by HPLC. Within 4h of the first intravitreal H37RA-mTB antigen injection, each animal developed epiphora, blepharospasm, mild corneal edema, aqueous flare, myosis, and vitreous opacity. The severity of signs peaked 48 to 72 h after injection and subsequently decreased back to normal within 14 days. Following the second injection, clinical signs in the eyes with the CsA device were less severe and significantly shorter in duration than signs with the polymer only implant eyes. Aqueous and vitreous humor protein levels, infiltrating cell numbers, total number of T-lymphocytes, and levels of IL-2 and IFN gamma-mRNA were significantly less in eyes with the CsA implant compared to eyes with the polymer only. CsA implants did not completely eliminate the development of a second ('recurrent') experimental inflammatory episode in these horses. However, the duration and severity of inflammation, cellular infiltration, tissue destruction, and pro-inflammatory cytokines RNA transcript levels were significantly less in those eyes implanted with the CsA device.
Collapse
|
33
|
Jaffe GJ, Yang CH, Guo H, Denny JP, Lima C, Ashton P. Safety and pharmacokinetics of an intraocular fluocinolone acetonide sustained delivery device. Invest Ophthalmol Vis Sci 2000; 41:3569-75. [PMID: 11006254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
Abstract
PURPOSE To determine the safety and pharmacokinetics of an intraocular fluocinolone acetonide sustained drug delivery device. METHODS Nonbiodegradable drug delivery devices containing 2 or 15 mg of a synthetic corticosteroid, fluocinolone acetonide, were constructed. The long-term in vitro release rates of these devices were determined in protein-free buffer or buffer containing 50% plasma protein. Fifteen-milligram devices were also implanted into the vitreous cavities of rabbit eyes. Intravitreal drug levels, the amount of drug remaining in explanted devices, and the release rate of explanted devices were determined over a 1-year time period. Drug toxicity was assessed over this same time period by slit lamp examination, indirect ophthalmoscopy, electroretinography, and histologic examination. RESULTS The drug release rates for the 2-mg device, 1.9 +/- 0.25 microg/d, and for the 15-mg device, 2.2 +/- 0.6 microg/d, remained linear over the 6-month and 45-day testing period, respectively. The release rate increased by approximately 20% when devices were transferred from protein-free buffer to buffer that contained protein (P: < 0.0001). Vitreous levels remained fairly constant (0.10-0.21 microg/ml) over a 1-year period. No drug was present in the aqueous humor during this time period. Based on the device release rates, the predicted life span of the 2- and 15-mg devices are 2.7 and 18.6 years, respectively. There was no evidence of drug toxicity by clinical examination, electroretinography, or histologic examination. CONCLUSIONS It is feasible to construct a nontoxic fluocinolone acetonide drug delivery device that reproducibly releases fluocinolone acetonide in a linear manner over an extended period. These devices show great promise in the treatment of ocular diseases such as uveitis, which are often managed with chronic corticosteroid therapy.
Collapse
|
34
|
Lai CC, Gouras P, Doi K, Tsang SH, Goff SP, Ashton P. Local immunosuppression prolongs survival of RPE xenografts labeled by retroviral gene transfer. Invest Ophthalmol Vis Sci 2000; 41:3134-41. [PMID: 10967075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
Abstract
PURPOSE To determine whether local immunosuppression with Cyclosporin A can influence the survival of human fetal retinal pigment epithelium (RPE) xenografts in the rabbit's subretinal space. METHODS Cultured human fetal RPE cells were transduced with the gene for green fluorescent protein (GFP) using a lentiviral vector. The RPE was transplanted into the subretinal space of rabbits that received intravitreal cyclosporine either by weekly injections (0. 25-0.5 mg) or by slow release (approximately 2 microg/d) from a capsule sutured into the vitreal cavity after prior cryopexy. The transplanted RPE was followed by GFP fluorescence scanning laser ophthalmoscopy and by histology of the transplant site. RESULTS RPE xenografts in eyes receiving intravitreal cyclosporine survived longer (several months) than they did in control eyes without cyclosporine. Survival was as long with slow release capsules as it was with weekly intravitreal injections at much higher concentrations of cyclosporine. CONCLUSIONS Local immunosuppression of the eye with cyclosporine prolongs the survival of RPE xenografts in the subretinal space of rabbits, implying that rejection involves activated T lymphocytes. Local immunosuppression with slow release capsules is as effective as weekly injections at much higher concentrations.
Collapse
|
35
|
Mohan R, Sivak J, Ashton P, Russo LA, Pham BQ, Kasahara N, Raizman MB, Fini ME. Curcuminoids inhibit the angiogenic response stimulated by fibroblast growth factor-2, including expression of matrix metalloproteinase gelatinase B. J Biol Chem 2000; 275:10405-12. [PMID: 10744729 DOI: 10.1074/jbc.275.14.10405] [Citation(s) in RCA: 193] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
We have studied mechanisms controlling activation of the gelatinase B gene (matrix metalloproteinase-9) by fibroblast growth factor-2 (FGF-2) during angiogenesis, and the effects of the natural product curcuminoids on this process. Using a transgenic mouse (line 3445) harboring a gelatinase B promoter/lacZ fusion gene, we demonstrate FGF-2 stimulation of reporter gene expression in endothelial cells of invading neocapillaries in the corneal micropocket assay. Using cultured corneal cells, we show that FGF-2 stimulates DNA binding activity of transcription factor AP-1 but not NF-kappaB and that AP-1 stimulation is inhibited by curcuminoids. We further show that induction of gelatinase B transcriptional promoter activity in response to FGF-2 is dependent on AP-1 but not NF-kappaB response elements and that promoter activity is also inhibited by curcuminoids. In rabbit corneas, the angiogenic response induced by implantation of an FGF-2 pellet is inhibited by the co-implantation of a curcuminoid pellet, and this correlates with inhibition of endogenous gelatinase B expression induced by FGF-2. Angiostatic efficacy in the cornea is also observed when curcuminoids are provided to mice in the diet. Our findings provide evidence that curcuminoids target the FGF-2 angiogenic signaling pathway and inhibit expression of gelatinase B in the angiogenic process.
Collapse
|
36
|
Ingrams DR, Ashton P, Dhingra J, Shah R, Shapshay SM. Slow-release 5-fluorouracil and triamcinolone reduces subglottic stenosis in a rabbit model. Ann Otol Rhinol Laryngol 2000; 109:422-4. [PMID: 10778898 DOI: 10.1177/000348940010900413] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A previous pilot study suggested that a sustained-release conjugate that provided a slow release of 5-fluorouracil and triamcinolone acetonide injected into the tracheal and paratracheal tissues of rabbits at the time of subglottic surgery reduced the formation of subglottic stenosis. Our study was undertaken to confirm the effect. Ten milligrams of the compound suspended in hyaluronic acid was injected at the time of injury via a laryngofissure approach. The results showed that the control group had a mean stenosis of 52%, whereas the treated group had a mean stenosis of 32%. There was a significant difference between the treated and untreated groups (p = .003). It is hoped that this co-drug ultimately can be used in humans to reduce stenosis formation after laryngotracheal surgery and in other forms of otorhinolaryngological surgery.
Collapse
|
37
|
Forbes S, Ashton P. The identity status of African Americans in middle adolescence: a reexamination of Watson and Protinsky (1991). ADOLESCENCE 1999; 33:845-9. [PMID: 9886012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
In contrast to earlier research, Watson and Protinsky (1991) found that African American students did not experience identity foreclosure to a greater extent than did their Caucasian peers. Watson and Protinsky, however, examined only ideological identity. The purpose of the present study was to extend this line of research by examining identity development in the interpersonal domain as well as the ideological domain. Forty-eight African American students completed a revised version of the Extended Objective Measure of Ego Identity Status (EOM-EIS II). Supporting the conclusions of Watson and Protinsky, the results showed that few of the African American students were foreclosed. Instead, most of the students were in moratorium; that is, they were engaged in the identity-exploration process. Results for the interpersonal domain were similar to those for the ideological domain.
Collapse
|
38
|
Ingrams DR, Sukin SW, Ashton P, Valtonen HJ, Pankratov MM, Shapshay SM. Does slow-release 5-fluorouracil and triamcinolone reduce subglottic stenosis? Otolaryngol Head Neck Surg 1998; 118:174-7. [PMID: 9482547 DOI: 10.1016/s0194-5998(98)80006-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The surgical management of subglottic stenosis may be complicated by reformation of strictures. A slow-release combination of 5-fluorouracil, which has an antiproliferative effect on fibroblasts, and the corticosteroid triamcinolone acetonide has been used experimentally to control scar production in ophthalmic operations. This study was performed to determine if this material also can be used to reduce formation of subglottic stenosis. Subglottic stenosis was induced in rabbits by means of injury to the subglottic mucosa and submucosa. A suspension of the compound at a concentration of 2.5 mg/ml or 12.5 mg/ml was injected into the adjacent soft tissues. A control group of rabbits received the same volume of the suspension fluid but no compound. Two rabbits from each group were killed 1, 2, and 12 weeks postoperatively. No stenosis was seen at 1 or 2 weeks, but at 12 weeks the rate of formation of subglottic stenosis was decreased to a mean of 15.20% in the experimental groups compared with 47.37% in the control group. There were no indications of local or systemic toxicity. The promising results from this preliminary study suggest that use of this compound may reduce restenosis among patients treated surgically for subglottic stenosis. Further studies are being conducted.
Collapse
|
39
|
Yang CS, Khawly JA, Hainsworth DP, Chen SN, Ashton P, Guo H, Jaffe GJ. An intravitreal sustained-release triamcinolone and 5-fluorouracil codrug in the treatment of experimental proliferative vitreoretinopathy. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 1998; 116:69-77. [PMID: 9445210 DOI: 10.1001/archopht.116.1.69] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To determine the efficacy and pharmacokinetics of an intravitreal sustained-release triamcinolone acetonide and 5-fluorouracil (TA/5-FU) codrug in the treatment of experimental proliferative vitreoretinopathy (PVR). METHODS The therapeutic efficacy of the TA/5-FU codrug was determined in a rabbit model that simulates human PVR. Intravitreal levels of triamcinolone and 5-fluorouracil were measured at different time points and drug release in vitro was tested. Toxic effects were evaluatedby electroretinograpy, clinical examination, and light microscopy. RESULTS Both the severity of PVR grade and the percentage of eyes with moderate or worse tractional detachment were significantly less in eyes treated with the codrug. The therapeutic effect of the intravitreal codrug was paralleled by sustained intravitreal levels of triamcinolone and 5-fluorouracil. There were no drug-related toxic effects evident on clinical or histopathologic examination of eyes containing the TA/5-FU codrug. CONCLUSIONS The intravitreal sustained-release TA/5-FU codrug effectively inhibits the progression of PVR in a rabbit model that closely resembles PVR in humans. The TA/5-FU codrug may simultaneously target different components of the wound-healing response.
Collapse
|
40
|
Jaffe GJ, Yang CS, Wang XC, Cousins SW, Gallemore RP, Ashton P. Intravitreal sustained-release cyclosporine in the treatment of experimental uveitis. Ophthalmology 1998; 105:46-56. [PMID: 9442778 DOI: 10.1016/s0161-6420(98)91176-9] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE Uveitis often is a chronic disease requiring long-term medical therapy. Despite treatment, the disease may be difficult to control and may produce serious, vision-threatening ocular complications. In this study, the authors determined whether an intravitreal cyclosporine-sustained delivery device was effective in the treatment of ocular inflammation in a rabbit model of uveitis. METHODS New Zealand White rabbits were immunized subcutaneously with Mycobacterium tuberculosis H37Ra antigen. Fourteen days later, sustained-release cyclosporine devices were implanted into the vitreous cavity of the right eye of experimental rabbits. Control animals received sham devices. Seven days after device implantation, rabbits were challenged with an intravitreal injection of tuberculin antigen. To simulate chronic inflammation with exacerbations, some animals were rechallenged with intravitreal antigen on day 21 after device implantation. Inflammation was assessed clinically by a masked observer who graded anterior chamber cells, flare, corneal neovascularization, iris congestion, and vitreous opacity daily until day 7 and on day 13 after the initial intravitreous challenge, and on days 1 and 2 after the rechallenge. Retinal function was evaluated by electroretinography. Animals were killed 3, 6, 8, and 14 days after the initial intravitreal challenge and on the second day after rechallenge for aqueous leukocyte count, protein measurement, and histologic examination. The number of aqueous and peripheral blood proliferating lymphocytes and the subset of CD4+ T cells were determined by flow cytometry. High-performance liquid chromatography was used to measure cyclosporine A levels in vitreous and peripheral blood. Light microscopy was used to evaluate the eyes histopathologically. RESULTS By clinical criteria, treated eyes had significantly less inflammation than untreated eyes. The number of aqueous cells and protein concentration determined quantitatively paralleled the clinical assessment of anterior chamber cells and flare. The electroretinography B-wave was depressed significantly in untreated eyes compared with that of treated eyes (P < 0.02). Histopathologic examination results showed marked inflammation and tissue disorganization in untreated eyes, whereas cyclosporine-treated eyes had preserved architecture and greatly reduced inflammatory cells. Intravitreal cyclosporine remained at therapeutic levels for at least 6 months after intravitreal device implantation, whereas blood levels were low to nondetectable. CONCLUSIONS The intravitreal cyclosporine A device effectively suppresses ocular inflammation in a rabbit model of uveitis. This device may be useful in the treatment of patients with severe chronic uveitis who are intolerant to currently available therapies.
Collapse
|
41
|
Martin DF, Ferris FL, Parks DJ, Walton RC, Mellow SD, Gibbs D, Remaley NA, Ashton P, Davis MD, Chan CC, Nussenblatt RB. Ganciclovir implant exchange. Timing, surgical procedure, and complications. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 1997; 115:1389-94. [PMID: 9366668 DOI: 10.1001/archopht.1997.01100160559005] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND The ganciclovir implant is effective for the treatment of cytomegalovirus (CMV) retinitis. The device eventually runs out of drug, however, and must be replaced. We report our experience with exchanging ganciclovir implants during the course of a randomized clinical trial. METHODS During our study, patients with newly diagnosed peripheral CMV retinitis were treated with a ganciclovir implant. The implant was scheduled for exchange at 32 weeks. It was exchanged earlier if progression of CMV retinitis occurred. Patient examinations and standard fundus photography were performed at 2-week intervals after the exchange procedure. RESULTS Twenty-six exchange procedures were performed. Twenty-two eyes in 15 patients received a second implant and 4 eyes in 4 patients later received a third implant. Cytomegalovirus retinitis was rendered or maintained inactive in 22 of 23 cases with more than 1 month of follow-up after the second or third implants. Complications after the second implant procedure included transient vitreous hemorrhage in 5 eyes, postoperative inflammation in 1 eye, and retinal detachment in 1 eye. Median visual acuity returned to 20/25 by 28 days and to 20/20 by 42 days. Complications after the third implant procedure included dense vitreous hemorrhage in 3 of 4 eyes. Median survival time after a second implant procedure was 89 days. CONCLUSIONS The initial ganciclovir implant exchange procedure is well tolerated with continued long-term control of CMV retinitis. Multiple reentries through the same wound may be associated with an increased risk for vitreous hemorrhage.
Collapse
|
42
|
Berger AS, Cheng CK, Pearson PA, Ashton P, Crooks PA, Cynkowski T, Cynkowska G, Jaffe GJ. Intravitreal sustained release corticosteroid-5-fluoruracil conjugate in the treatment of experimental proliferative vitreoretinopathy. Invest Ophthalmol Vis Sci 1996; 37:2318-25. [PMID: 8843916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
PURPOSE Proliferative vitreoretinopathy (PVR) remains the most common cause of failed retinal detachment (RD) surgery. The authors compared the effectiveness of two intraocular sustained-release codrugs in suppressing PVR in a rabbit model a surgically implantable pellet releasing 5-fluorouracil (FU) and dexamethasone (DX) for 1 week and an injectable intravitreal sustained-release suspension releasing 5-FU and triamcinolone acetonide for 1 month. METHODS Sustained-release devices and suspensions were prepared to deliver equimolar quantities of corticosteroid and 5-FU. In group 1, devices were implanted surgically into the vitreous of the right eye of 10 New Zealand White rabbits. Ten control rabbits received surgical implantation of the suture only. In group 2, drug suspension was injected into the vitreous of the right eye of 10 New Zealand White rabbits. Ten control rabbits received injection of the vehicle only. One day later, each rabbit was injected intravitreally with 250,000 homologous rabbit dermal fibroblasts. Severity of PVR was graded clinically by two masked observers on days 3, 7, 10, 14, 21, and 28. RESULTS In group 1, clinical severity of PVR was less in the experimental group than in the control group at all time points, this was only statistically significant on day 10 (P = 0.04). Six eyes developed moderate to severe tractional RD or bullous RD in the control group by day 10 compared with none in the experimental group (P = 0.01). In group 2, the median clinical grading of eyes in the experimental group was significantly less than that in the control group at all time points through day 21 (P < or = 0.01). CONCLUSIONS Both the intravitreal sustained-release dexamethasone-5-FU device and the triamcinolone-5-FU suspension effectively inhibit the progression of PVR in a rabbit model. Simultaneous delivery of 5-FU and corticosteroid may target different components of the wound-healing process in this disease.
Collapse
|
43
|
Langner A, Ashton P, Van De Kerkhof PC, Verjans H. A long-term multicentre assessment of the safety and tolerability of calcitriol ointment in the treatment of chronic plaque psoriasis. Br J Dermatol 1996; 135:385-9. [PMID: 8949430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Calcitriol (1 alpha,25-dihydroxyvitamin D3), applied topically in an ointment base, has been shown to be effective in the treatment of chronic plaque psoriasis. This open study was designed to assess the safety and tolerability of 3 micrograms/g calcitriol ointment applied twice daily over treatment periods of up to 78 weeks. In the 253 evaluable patients with chronic plaque psoriasis no clinically relevant changes were observed in the baseline/end-point analyses of mean serum levels of total calcium, albumin-adjusted total calcium, phosphorus and creatinine, and plasma calcitriol levels. Mean values of 24-h urinary calcium, phosphorus, creatinine and hydroxyproline excretions, creatinine clearance and mean urinary calcium/creatinine ratio also did not show clinically relevant changes in the baseline/end-point analyses. The treatment was well tolerated, with no serious adverse events occurring during the course of the study. Eight patients withdrew from the study due to adverse events which, although not serious, were thought to be treatment-related: in seven patients skin irritation reactions and in one case a transient asymptomatic slight hypercalcaemia was observed. In addition, assessments of global severity, global improvement and Psoriasis Area and Severity Index scores confirmed the therapeutic efficacy of twice daily 3 micrograms/g calcitriol ointment demonstrated in an earlier controlled study. In conclusion, this study demonstrated that twice daily application of 3 micrograms/g calcitriol ointment is safe and well-tolerated in the treatment of chronic plaque psoriasis.
Collapse
|
44
|
|
45
|
Smith TJ, Ashton P. Sustained-release subconjunctival 5-fluorouracil. OPHTHALMIC SURGERY AND LASERS 1996; 27:763-7. [PMID: 8878194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND AND OBJECTIVES The purpose of this research was to obtain preliminary safety and efficacy data on a novel sustained-release 5-fluorouracil (5-FU) implant in high-risk glaucoma surgical patients. PATIENTS AND METHODS The implants were placed subconjunctivally in four patients undergoing high-risk trabeculectomy. The patients have been observed for approximately 2.5 years. RESULTS In three of the four patients intraocular pressure was controlled at less than 21 mm Hg, with stabilization of the visual field. One patient had early failure. No untoward events were linked to the placement of the implant. CONCLUSION Sustained-release systems for subconjunctival 5-FU may be useful in filter maintenance.
Collapse
|
46
|
Duker JS, Ashton P, Davis JL, Keller R, Chuang E. Long-term, successful maintenance of bilateral cytomegalovirus retinitis using exclusively local therapy. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 1996; 114:881-2. [PMID: 8660179 DOI: 10.1001/archopht.1996.01100140095021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
47
|
Enyedi LB, Pearson PA, Ashton P, Jaffe GJ. An intravitreal device providing sustained release of cyclosporine and dexamethasone. Curr Eye Res 1996; 15:549-57. [PMID: 8670756 DOI: 10.3109/02713689609000766] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE A device that releases cyclosporine and dexamethasone into the eye for extended periods of time might be beneficial in diseases such as proliferative vitreoretinopathy and uveitis. In this study we examine the pharmacokinetics and toxicity of cyclosporine and dexamethasone combined in an intravitreal sustained-release device and the toxicity of a similar device containing only dexamethasone in rabbits. METHODS Rabbits were divided into three groups for (1) evaluation of the drug tissue levels and device release kinetics following implantation of a device containing 100 micrograms of cyclosporine labeled with 2 microCi of 3H-cyclosporine and 2 mg of dexamethasone; (2) evaluation of the toxicity of this intravitreal device; and (3) evaluation of the toxicity of a similar device containing 2 mg of dexamethasone only. Cyclosporine was measured using a scintillation counter and dexamethasone was measured by high pressure liquid chromatography (HPLC). Toxicity was evaluated by electroretinography, clinical examination, and light microscopy. RESULTS Vitreous concentrations of cyclosporine (+/- standard deviation) averaged 0.06 (+/- 0.02) microgram/ml over 10 weeks. The average dexamethasone concentration over the 10 week period was 2.9 (+/- 0.9) micrograms/ml. Devices containing cyclosporine and dexamethasone released each drug at rates similar to devices containing cyclosporine or dexamethasone alone. Devices containing both cyclosporine and dexamethasone caused reversible depressions in the b-wave amplitude of photopic and scotopic electroretinograms (ERG's). There was no evidence of toxicity associated with the devices containing dexamethasone only. There was no drug-related toxicity evident on clinical or histopathologic examination of eyes with devices containing the combination of cyclosporine and dexamethasone or dexamethasone alone. CONCLUSIONS We conclude that the device maintains potentially therapeutic levels of both cyclosporine and dexamethasone in the vitreous. Reversible electroretinographic abnormalities are attributable to cyclosporine. A sustained-release device containing cyclosporine and dexamethasone may be useful for reducing inflammation in diseases such as proliferative vitreoretinopathy and uveitis.
Collapse
|
48
|
Steffansen B, Ashton P, Buur A. Intraocular drug delivery. In vitro release studies of 5-fluorouracil from N1-alkoxycarbonyl prodrugs in silicone oil. Int J Pharm 1996. [DOI: 10.1016/0378-5173(95)04376-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
49
|
Pearson PA, Jaffe GJ, Martin DF, Cordahi GJ, Grossniklaus H, Schmeisser ET, Ashton P. Evaluation of a delivery system providing long-term release of cyclosporine. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 1996; 114:311-7. [PMID: 8600892 DOI: 10.1001/archopht.1996.01100130307014] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVES To examine the clearance of cyclosporine after intravitreal injection and to assess the kinetics and toxic effects of an intravitreal device that provides sustained delivery of cyclosporine. METHODS Rabbits were divided into two groups to evaluate (1) the elimination kinetics after 1-microgram and 10-microgram intravitreal injections of cyclosporine and (2) the levels produced after implantation of a device that contained cyclosporine over 6 months. The toxic effects of the intravitreal device over 6 months were assessed in rabbits and cynomolgus monkeys. RESULTS After the 10-microgram injection, the half-life was longer (10.8 hours vs. 4.2 hours) and the distribution volume was smaller (1.7 mL vs 3.2 mL) than after the 1-microgram injection. This difference can be attributed to saturable partitioning of the drug. The device resulted in a vitreous concentration of approximately 500 ng/mL throughout the study period. In the rabbit it resulted in reversible lens opacification and decreased b-wave amplitude. This toxic effect was not detected in the monkey. CONCLUSIONS The device produces sustained intravitreal levels of cyclosporine. Although it was associated with reversible toxic effects in the rabbit, it was well tolerated in primates. Sustained-release implants are a promising new treatment for chronic uveitis.
Collapse
|
50
|
Hainsworth DP, Pearson PA, Conklin JD, Ashton P. Sustained release intravitreal dexamethasone. J Ocul Pharmacol Ther 1996; 12:57-63. [PMID: 8925398 DOI: 10.1089/jop.1996.12.57] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Sustained intravitreal levels of dexamethasone may be useful in the treatment of proliferative vitreoretinopathy (PVR). The preparation and evaluation of an implantable system for intravitreal sustained release of dexamethasone is described. Pellets of dexamethasone were coated in biocompatible, nonerodible polymers and the release rate tested in vitro. Devices were then implanted in the rabbit vitreous and the in vivo release rate and corresponding steady state vitreous concentration determined. Toxicity was also evaluated by histopathology and electrographic examination. Devices released dexamethasone at approximately 1 ug/hr in vitro and 1.5 ug/hr in vivo. When implanted into the vitreous intravitreal concentrations of approximately 2.5 +/- 1.2 ug/hr were maintained for over 3 months. Devices were well tolerated with no evidence of inflammation or retinal abnormalities.
Collapse
|