26
|
Bayer S, Stark H, Gölz L, Keilig L, Kraus D, Hansen A, Enkling N. Telescopic crowns: extra-oral and intra-oral retention force measurement--in vitro/in vivo correlation. Gerodontology 2011; 29:e340-7. [PMID: 21453418 DOI: 10.1111/j.1741-2358.2011.00477.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE This study deals with the determination of the retentive forces of telescopic crowns measured extra- and intra-orally and the correlation of these values. BACKGROUND The telescopic denture is a well-documented solution for prosthetic rehabilitation for a partially edentulous jaw. Acceptable retention forces are needed to avoid inadvertent removal of the denture during movement of the jaws. Recent literature suggests 3-7 N per attachment to be acceptable. These values are only supported by in vitro studies. In vivo data are scarce, and a correlation of the in vitro and in vivo values is lacking. MATERIAL AND METHODS Twenty-five combined fixed-removable prostheses with a total of 72 double crowns were used for extra-oral retention force measurement prior to cementation (in vitro). The intra-oral measurement was performed at 72 defined measuring points of the dentures 4-6 weeks after prosthetic rehabilitation (in vivo). A specifically designed measuring device was used. RESULTS The rank correlation showed that the in vitro and in vivo values correlate with each other (Spearman's ρ = 0.5052). Additionally, it was found that the median values measured before (1.97N) insertion of the dentures were significantly lower than after (4.70N) insertion (Mann-Whitney test, p ≤ 0.0001). CONCLUSION The retention forces measured before and after insertion of the denture correlate with each other although their dimension is significantly higher after insertion. The reason for this behaviour might be some tilting during removal. Nevertheless, the correlation allows a prediction of the clinically relevant forces by a measurement of the extra-orally measured retentive values.
Collapse
|
27
|
Bayer S, Stark H, Gölz L, Keilig L, Kraus D, Hansen A, Enkling N. Clinical retention force development of double crowns. Clin Oral Investig 2011; 16:407-11. [DOI: 10.1007/s00784-011-0530-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2010] [Accepted: 02/16/2011] [Indexed: 11/28/2022]
|
28
|
Enkling N, Jöhren P, Klimberg V, Bayer S, Mericske-Stern R, Jepsen S. Effect of platform switching on peri-implant bone levels: a randomized clinical trial. Clin Oral Implants Res 2011; 22:1185-1192. [PMID: 21320171 DOI: 10.1111/j.1600-0501.2010.02090.x] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
29
|
Enkling N, Jöhren P, Klimberg T, Mericske-Stern R, Jervøe-Storm PM, Bayer S, Gülden N, Jepsen S. Open or submerged healing of implants with platform switching: a randomized, controlled clinical trial. J Clin Periodontol 2011; 38:374-84. [PMID: 21235615 DOI: 10.1111/j.1600-051x.2010.01683.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIM The temporal pattern of bone-level alterations in conventionally restored implants is dependent upon healing mode (open or submerged). This study examined the influence of healing on marginal bone levels at implants with a medium-rough surface including the implant collar and a clearance-fit implant-abutment connection restored according to a platform-switching concept. MATERIAL AND METHODS Two implants were placed in the posterior mandible of 21 test subjects, randomly assigned to open (OH) or submerged (SH) healing. Standardized radiographs were obtained after implant surgery, before re-entry, after crown mounting, 1 and 2 years after implant surgery, and evaluated for implant-bone-level alterations (ΔIBL). Bacterial samples of the implants' inner cavities were analysed by cultivation. STATISTICS Brunner-Langer Model, equivalence testings by Wilcoxon's (equivalence range ±0.4mm). RESULTS After 2 years, ΔIBL were -0.47±0.46mm (OH) and -0.54±0.38mm (SH). At the 1-year follow-up, all implants were contaminated with bacteria. ΔIBL (p<0.001) and the amount of bacterial contamination (p<0.001) significantly depended on time, but not on healing mode. ΔIBL of OH and SH were equivalent at all time points (all p0.044). CONCLUSIONS Platform-switched implants showed very limited peri-implant bone-level alterations. The healing-mode neither affected the total amount nor the temporal patterns of ΔIBL. Thus, the results for the tested implants with a non-rigid implant-abutment connection were similar to results reported previously for implants with a rigid implant-abutment connection.
Collapse
|
30
|
Enkling N, Utz KH, Bayer S, Stern RM. Osseoperception: active tactile sensibility of osseointegrated dental implants. Int J Oral Maxillofac Implants 2010; 25:1159-1167. [PMID: 21197493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023] Open
Abstract
PURPOSE The phenomenon of developing a certain tactile sensibility through osseointegrated dental implants is called osseoperception. Active tactile sensibility can be tested by having the subject bite on test bodies. The aim of the study was to describe the active tactile sensibility of single-tooth implants based on the 50% value and the slope of the sensibility curve at the 50% value. MATERIALS AND METHODS Sixty-two subjects with single-tooth implants with natural opposing teeth were included in the study. In a computer-assisted and randomized way, copper foils of varying thickness (0 to 200 Μm) were placed inter?occlusally between the single-tooth implant and the natural opposing tooth, and the active tactile perception was studied according to the psychophysical method of constant stimuli and statistically evaluated by logistic regression. RESULTS Tactile perception of the implants at the 50% value estimated by logistic regression was 20.2 ± 10.9 Μm on average, and the slope was 29 ± 15. Regarding implant surface structure, significant differences were observed. The sandblasted and acid-etched surface was significantly more sensitive than the titanium plasma-sprayed surface, and the machined surface was similar to the titanium plasma-sprayed surface. CONCLUSIONS Active tactile sensibility of implants with natural antagonistic teeth is very similar to that of teeth, but the slope of the tactile sensibility curve is flatter. Significant differences in tactile sensibility as a function of different implant surfaces may indicate that receptors near the implant form the basis of osseoperception.
Collapse
|
31
|
Bayer S, Zuziak W, Kraus D, Keilig L, Stark H, Enkling N. Conical crowns with electroplated gold copings: retention force changes caused by wear and combined off-axial load. Clin Oral Implants Res 2010; 22:323-9. [PMID: 20868454 DOI: 10.1111/j.1600-0501.2010.02003.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
32
|
Bayer S, Keilig L, Kraus D, Grüner M, Stark H, Mues S, Enkling N. Influence of the lubricant and the alloy on the wear behaviour of attachments. Gerodontology 2010; 28:221-6. [PMID: 20545776 DOI: 10.1111/j.1741-2358.2009.00352.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Wear of attachments leads to a loss of retention and reduces the function of overdentures. This study evaluated the retention force changes of an attachment system for overdentures. The influence of the lubricant and the alloy on wear constancy was examined. METHODS Cylindrical anchors of the Dalbo(®) -Z system were tested (Cendres+Métaux SA). Three groups of alloy-lubricant combinations were generated 1.Elitor(®) /NaCl-solution (EN) 2.Elitor(®) /Glandosane(®) aquadest. (EG) and 3.Valor(®) /Glandosane(®) /aquadest. (VG). Ten samples of each group were subjected to 10 000 insertion-separation cycles. RESULTS For the EN-group, this led to a large increase in retention force. The EG- and VG-group showed a constant decrease after an initial increase in retention force at the beginning of the wear simulation. The change of the alloy caused no statistically significant differences. The use of a more viscous lubricant reduced the retention force increase significantly. CONCLUSIONS The use of a lubricant which simulates clinical conditions is an absolute need for wear simulation because the retention force changes are influenced enormously. The change of the alloy at the Dalbo(®) -Z system did not influence the wear behaviour. As a slight decrease in retention force was recorded, it is useful for an attachment system to allow compensation with an adjustable matrix.
Collapse
|
33
|
Bayer S, Helfgen EH, Bös C, Kraus D, Enkling N, Mues S. Prevalence of findings compatible with carotid artery calcifications on dental panoramic radiographs. Clin Oral Investig 2010; 15:563-9. [PMID: 20431901 DOI: 10.1007/s00784-010-0418-6] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2009] [Accepted: 04/19/2010] [Indexed: 11/28/2022]
Abstract
Cerebrovascular accidents are responsible for killing or disabling more than half a million Americans every year. They are the third leading cause of death in this country. In Germany, the annual stroke incidence reaches 182 cases per 100,000 inhabitants. Stroke there is the fourth leading cause of death. There is a need of finding cost-effective means of decreasing stroke mortality and morbidity. Instruments for early diagnosis are of great humanitarian and economic importance. All possible clinical findings should be taken into account. It is not the demand of this study to present the panoramic radiograph as a screening test method for early diagnosis of atherosclerosis. The aim is to show the potential of this radiograph used in everyday clinical dental practice by the prevalence of radiopaque findings in the carotid region. This study included panoramic dental radiographs of 2,557 patients older than 30 years of age. Fifty-nine percent of the patients were women and 41% were men. The radiographs were adjudged for signs compatible with carotid arterial calcifications appearing as a radiopaque nodular mass adjacent to the cervical vertebrae at or below the intervertebral space C3-4. Of all these radiographs, 4.8% showed radiopaque findings compatible with atherosclerotic lesions. The proportion of women reached 64.8% and that of men reached 35.2%. In accordance to recent literature, the results of this study show that about 5% of the patients show radiological findings compatible with carotid arterial calcifications. Some of these patients at risk for a cerebrovascular accident may be identified in the dentist's office by appropriate review of the panoramic dental radiograph. The suspicion of carotid artery calcifications demands an impetuous referral to an appropriate practitioner who can assist in the control of risk factors and if necessary arrange surgical removal of the carotid arterial plaque. So, the dentist should be aware of this problem and able to make a contribution to stroke prevention.
Collapse
|
34
|
Enkling N, Heussner S, Nicolay C, Bayer S, Mericske-Stern R, Utz KH. Tactile Sensibility of Single-Tooth Implants and Natural Teeth Under Local Anesthesia of the Natural Antagonistic Teeth. Clin Implant Dent Relat Res 2009; 14:273-80. [DOI: 10.1111/j.1708-8208.2009.00252.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
35
|
Khan E, Bayer S, Kempe R, Wrackmeyer B. Synthesis and Molecular Structure of Silole Derivatives Bearing Functional Groups on Silicon: 1,1‐Organoboration of Dialkynylsilanes. Eur J Inorg Chem 2009. [DOI: 10.1002/ejic.200900697] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
36
|
Enkling N, Nicolay C, Bayer S, Mericske-Stern R, Utz KH. Investigating interocclusal perception in tactile teeth sensibility using symmetric and asymmetric analysis. Clin Oral Investig 2009; 14:683-90. [DOI: 10.1007/s00784-009-0348-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2009] [Accepted: 09/24/2009] [Indexed: 11/24/2022]
|
37
|
Enkling N, Bayer S, Jöhren P, Mericske-Stern R. Vinylsiloxanether: A New Impression Material. Clinical Study of Implant Impressions with Vinylsiloxanether versus Polyether Materials. Clin Implant Dent Relat Res 2009; 14:144-51. [DOI: 10.1111/j.1708-8208.2009.00240.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
38
|
Bayer S, Ballschmiter M, Greiner-Stoeffele T. Identification of a new lipolytic enzyme family and several novel nitrilases in metagenomic libraries. N Biotechnol 2009. [DOI: 10.1016/j.nbt.2009.06.317] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
39
|
Bayer S, Steinheuser D, Grüner M, Keilig L, Enkling N, Stark H, Mues S. Comparative study of four retentive anchor systems for implant supported overdentures--retention force changes. Gerodontology 2009; 26:268-72. [PMID: 19371390 DOI: 10.1111/j.1741-2358.2009.00286.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. METHODS Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10,000 insertion-separation cycles. RESULTS Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. CONCLUSIONS Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.
Collapse
|
40
|
Keilig L, Stark H, Bayer S, Utz KH, Strazza M, Grüner M, Bourauel C. Numerical investigation of the mechanical loading of supporting soft tissue for partial dentures. INT J PROSTHODONT 2009; 22:201-203. [PMID: 19418869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The aim of this research was to study the impact of loading on partial dentures within the supporting soft tissue with respect to different attachment techniques. A finite element model was developed to calculate the stress and strain distribution in this tissue. The model consisted of the left half of a mandible with three remaining teeth that had suffered an atrophy in the anterior region, and a partial denture over the toothless area that was connected at the left mandibular canine using an attachment system. Resulting stress/strain distributions are presented for different load cases using a commercially available prefabricated attachment system.
Collapse
|
41
|
Bayer S, Grüner M, Keilig L, Hültenschmidt R, Nicolay C, Bourauel C, Utz KH, Stark H. Investigation of the wear of prefabricated attachments--an in vitro study of retention forces and fitting tolerances. QUINTESSENCE INTERNATIONAL (BERLIN, GERMANY : 1985) 2007; 38:e229-37. [PMID: 17568826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
OBJECTIVE To quantify wear processes by measuring the retention force changes and the fitting tolerance at different prefabricated attachment systems to estimate the wear constancy and applicability in clinical practice. METHOD AND MATERIALS Seven prefabricated attachment systems (Dalbo-Classic, Dalbo-PLUS, Dalbo-Z, Mini-Gerber-PLUS, Stufenexzenter, SpharoLock, and Degussa-Kugelankersystem) with different construction and alloy composition were tested. Twenty samples of each system were subjected to 10,000 insertion-separation cycles in a wear simulator with a periodontium-simulating specimen holder. The simulator was designed to record the force needed to insert and to separate the attachment and the distance moved during the insertion and separation cycles. RESULTS All types of anchors showed wear that led to a loss or to an increase in retention force at the beginning of the wear simulation. Anchors with a plastic retention insert showed the slightest changes in retention force. The wear does not have an effect on the fitting tolerance. CONCLUSION Anchor systems that possess an adjustable matrix should be preferred. They allow decreasing or increasing the retention force of an anchor if this force is changed by wear. There is no risk of a loss of support if forces in occlusal direction are exerted because there is no clinically relevant change in the fitting tolerance.
Collapse
|
42
|
Pettitt M, Burnett G, Bayer S, Stevens A. Assessment of the occlusion technique as a means for evaluating the distraction potential of driver support systems. ACTA ACUST UNITED AC 2006. [DOI: 10.1049/ip-its:20060027] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
43
|
Méry J, Bayer S. Comparison of external costs between dry tomb and bioreactor landfills: taking intergenerational effects seriously. WASTE MANAGEMENT & RESEARCH : THE JOURNAL OF THE INTERNATIONAL SOLID WASTES AND PUBLIC CLEANSING ASSOCIATION, ISWA 2005; 23:514-26. [PMID: 16379120 DOI: 10.1177/0734242x05060857] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Dry tomb and bioreactor landfills were analyzed with respect to their external costs in an intergenerational cost-benefit analysis in a partial framework which enabled a sounder comparison to be carried out between these two technologies from a socio-economic viewpoint. Obviously, this approach was only a first step for building a comprehensive basis of any environmental as well as fiscal policy in the field of waste management. All external costs are identified and evaluated in three different scenarios, corresponding to a worst case, a best guess and a best case. Obviously, discounting is crucial with respect to an intergenerational perspective. Generation-adjusted discounting (GAD) was applied to take into account equity as well as efficiency criteria, in order to deal with three different types of uncertainties that are decisive in waste policy decisions: a physical uncertainty is captured by introducing our three different scenarios; a macroeconomic uncertainty is taken into consideration by calculating present values using different real growth rates; and a microeconomic uncertainty is taken into account by considering individual peculiarities reflected in their subjective time preference rate. The findings show, that whenever there is a low real GDP growth of less than 1%, the bioreactor is generally superior to the dry tomb (lower present values of external costs). This statement becomes more valid as the growth rate decreases. However, whenever there are high positive growth rates, it is the dry tomb technology which is superior to the bioreactor system.
Collapse
|
44
|
Voigt M, Bayer S, Dudenhausen JW. Veränderung der somatischen Klassifikation Neugeborener nach Schwangerschaftsdauer und Geburtsgewicht durch den täglichen Zigarettenkonsum der Mütter in der Schwangerschaft. Z Geburtshilfe Neonatol 2004. [DOI: 10.1055/s-2003-818288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
45
|
Bayer S. Nachhaltigkeitskonforme Diskontierung – Das Konzept des „Generation Adjusted Discounting“. ACTA ACUST UNITED AC 2004. [DOI: 10.3790/vjh.73.1.142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
46
|
Keilig L, Bourauel C, Grüner M, Hültenschmidt R, Bayer S, Utz KH, Stark H. Aufbau und Erprobung eines neuartigen Meßsystems für die dentale Biomechanik – Meßprinzip und Beispielmessungen des Hexapod-Meß-Systems / Design and Testing of a Novel Measuring Set-up for Use in Dental Biomechanics – Measuring Principle and Exemplary Measurements with the Hexapod Measuring System. BIOMED ENG-BIOMED TE 2004; 49:208-15. [PMID: 15481409 DOI: 10.1515/bmt.2004.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A novel measuring set-up based on a hexapod system for use in dental biomechanics is described. It was specially developed to measure force/deflection characteristics of different dental materials and devices. The functionability and suitability of the system for use in experimental biomechanics were investigated in two different studies. In a first study the micro mobility of prosthetic telescopic crowns prior to and after simulated wear was determined to investigate the influence of wear processes on the stability of the anchorage elements and thus of prostheses. This study investigated the ability of the setup to load a specimen with high forces or torques of up to 100 Newton. The second study looked at the force/deflection characteristics of orthodontic anchorage pins used in orthodontics to additionally stabilize the anchorage unit, for example during molar movement. In this study specimens were loaded with small forces of less than 10 Newton, as are typically used in orthodontics. Using the setup, the deflection behaviour of these devices under high and low loading was measured at a resolution of approximately one micrometer or one angular second.
Collapse
|
47
|
|
48
|
Bayer S, Crenner F, Aunis D, Angel F. Effects of GABA on circular smooth muscle spontaneous activities of rat distal colon. Life Sci 2002; 71:911-25. [PMID: 12084388 DOI: 10.1016/s0024-3205(02)01771-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
GABAergic regulation of intestinal motility through the modulation of non-adrenergic non-cholinergic (NANC) neurons remains poorly understood especially in rat colon where very few studies have been undertaken. Therefore, the effects of GABA on circular preparations of rat distal colon were investigated using classical organ bath chambers to record spontaneous mechanical activities (SMA). SMA was characterized by the occurrence of rhythmic phasic contractions (type-I) or by spontaneously occurring large contractions superimposed on small rhythmic contractions (type-II). In the presence of atropine and guanethidine (NANC conditions), these large contractions were inhibited by bicuculline, a GABA(A)-receptor antagonist as well as by TTX, L-NAME and apamin together, or L 732-138, a NK1-receptor antagonist. In NANC conditions, GABA induced a transient monophasic relaxation or a biphasic effect characterized by a relaxation followed by a tonic contraction in both type-I and -II preparations. Both the inhibitory and excitatory effects of GABA were blocked by TTX and L-NAME + apamin; the GABA-induced contraction was also sensitive to L 732-138. The responses to GABA were mimicked by the GABA(A)-receptor agonist, muscimol, whereas baclofen and CACA, respectively GABA(B) and GABA(C)-receptors agonists showed no effect. These results demonstrated that only GABA(A)-receptors seem to be involved in the regulation of SMA in rat distal colon in NANC conditions. Release of NANC inhibitory transmitter (NO and probably ATP) and NANC excitatory transmitter (maybe substance P) might be involved.
Collapse
|
49
|
Kehm E, Göksu M, Bayer S, Knopf CW. Herpes simplex virus type 1 DNase: functional analysis of the enzyme expressed by recombinant baculovirus. Intervirology 2000; 41:110-9. [PMID: 9820845 DOI: 10.1159/000024922] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Herpes simplex virus type 1 DNase (HSV-1 DNase) was expressed in insect cells by recombinant baculovirus (NPVUL12) and purified by a combination of anionic exchanger chromatography and gel filtration. Two polypeptides of 85 and 75 kD, whose ratio varied during purification, were induced 24 h after infection. The 75-kD protein was isolated and shown to possess catalytic activity. Gel filtration analysis indicated that the active form of the enzyme at an ionic strength of I = 0.3 is a dimeric protein with an apparent molecular weight of 130,000. The recombinant enzyme exhibited the overall characteristics of the native enzyme such as 5'-3' exonuclease and endonuclease activities with a preferred degradation of DNA. In the absence of extraneously added Mg2+, the enzyme was capable of removing mononucleotides from 5'-end-labeled DNA, but not from RNA and 3'-end-labeled DNA. The peculiar mechanism of double-strand DNA degradation suggests a specific role of HSV-1 DNase in DNA recombination processes during viral replication.
Collapse
|
50
|
Ward N, Bayer S, Ballard M, Patience T, Hume RF, Calhoun BC. Impact of prenatal care with reduced frequency of visits in a residency teaching program. THE JOURNAL OF REPRODUCTIVE MEDICINE 1999; 44:849-52. [PMID: 10554744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
OBJECTIVE To determine if decreasing the number of prenatal visits for routine obstetric patients affects pregnancy outcome. STUDY DESIGN A historical control study was designed to include 734 deliveries from January 1 to December 31, 1991, in women who had prenatal care per American College of Obstetricians and Gynecologists Committee Opinion no. 79, January 1990, guidelines for uncomplicated obstetric care. A prospective study cohort of women with 711 deliveries from January 1 to December 31, 1994, underwent prenatal care with modified guidelines to include: first visit at 6-12 weeks to confirm dating and obtain initial laboratory data, second visit at 16-20 weeks to obtain maternal serum alpha-fetoprotein screening, third visit at 24-28 weeks for 28-week laboratory data, fourth visit at 32 weeks, fifth visit at 36 weeks, sixth visit at 38 weeks, seventh visit at 40 weeks and weekly thereafter. Pregnancy outcomes included estimated fetal weight, gestational age at delivery, preeclampsia, Apgar score at one and five minutes and delivery mode. Neonatal outcomes, including stillbirth rate, preterm delivery rate, intraventricular hemorrhage rate, bronchopulmonary dysplasia and neonatal mortality, were evaluated. RESULTS There were no statistically significant differences in perinatal or neonatal outcomes with decreased prenatal visits from an average of 12 per pregnancy to 8. CONCLUSION Prenatal visits can be decreased in a teaching hospital in women with uncomplicated pregnancies from the standard number, 12-14 visits, to an average of 7 or 8 per patient without adverse perinatal outcomes.
Collapse
|