26
|
Mein S, Tessonnier T, Kopp B, Debus J, Haberer T, Abdollahi A, Mairani A. Next Evolutions in Particle Therapy: Spot-Scanning Hadron Arc (SHArc) Therapy. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
27
|
Tessonnier T, Mein S, Besuglow J, Kopp B, Ecker S, Naumann J, Ellerbrock M, Held T, Haberer T, Debus J, Mairani A. Next Evolutions in Particle Therapy: Helium Ion Treatment Planning, Delivery and Clinical Implications of Biological Modeling. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.1414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
28
|
Mairani A, Tessonnier T, Mein S, Walsh D, Liew H, Weber U, Brons S, Debus J, Haberer T, Abdollahi A, Dokic I. FLASH Dose-Rate Helium Ion Beams: First In Vitro Investigations. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
29
|
Liew H, Meister S, Mein S, Tessonnier T, Kopp B, Held T, Haberer T, Abdollahi A, Debus J, Dokic I, Mairani A. Combined DNA Damage Repair Interference and Ion Beam Therapy: Development, Benchmark, and Clinical Implications of a Mechanistic Biological Model. Int J Radiat Oncol Biol Phys 2021; 112:802-817. [PMID: 34710524 DOI: 10.1016/j.ijrobp.2021.09.048] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 09/10/2021] [Accepted: 09/28/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE Our purpose was to develop a mechanistic model that describes and predicts radiation response after combined DNA damage repair interference (DDRi) and particle radiation therapy. METHODS AND MATERIALS The heterogeneous dose distributions of protons and 4He ions were implemented into the "UNIfied and VERSatile bio-response Engine" (UNIVERSE). Predictions for monoenergetic and mixed fields over clinically relevant dose and linear energy transfer range were compared with experimental in vitro survival data measured in this work as well as data available in the literature, including different cell lines and DDR interferences. Ultimately, UNIVERSE predictions were investigated in a patient plan. RESULTS UNIVERSE accurately predicts survival of cell lines with and without DDRi in clinical settings of ion beam therapy based only on 3 parameters derived from photon data. With increasing dose or linear energy transfer, the radiosensitizing effect of DDRi decreases, resulting in diminished relative biological effect of ion beam radiation for cells subjected to DDRi in comparison to cells that are not. Similar trends were observed in patient plan recalculations; however, this analysis also suggests that DDRi + particle radiation therapy may better preserve the therapeutic window in comparison to DDRi + photon radiation therapy. CONCLUSIONS The presented framework represents the first mechanistic model of combined DDRi and particle radiation therapy comprehensively benchmarked in clinically relevant scenarios and a step toward more personalized treatment. It reveals potential differences between DDRi + photon radiation therapy versus DDRi + particle radiation therapy, which have not been described so far. UNIVERSE could aid in appraising the clinical viability of combined administration of radiosensitizing drugs and charged particle therapy, as well as the identification of patients with known DDR deficiencies in the tumor who might benefit from therapy with light ions, freeing limited space at heavy ion therapy centers.
Collapse
|
30
|
Freitas H, Magalhaes Martins P, Tessonnier T, Ackermann B, Brons S, Seco J. Dataset for predicting single-spot proton ranges in proton therapy of prostate cancer. Sci Data 2021; 8:252. [PMID: 34588458 PMCID: PMC8481263 DOI: 10.1038/s41597-021-01028-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 08/05/2021] [Indexed: 11/09/2022] Open
Abstract
The number of radiotherapy patients treated with protons has increased from less than 60,000 in 2007 to more than 220,000 in 2019. However, the considerable uncertainty in the positioning of the Bragg peak deeper in the patient raised new challenges in the proton therapy of prostate cancer (PCPT). Here, we describe and share a dataset where 43 single-spot anterior beams with defined proton energies were delivered to a prostate phantom with an inserted endorectal balloon (ERB) filled either with water only or with a silicon-water mixture. The nuclear reactions between the protons and the silicon yield a distinct prompt gamma energy line of 1.78 MeV. Such energy peak could be identified by means of prompt gamma spectroscopy (PGS) for the protons hitting the ERB with a three-sigma threshold. The application of a background-suppression technique showed an increased rejection capability for protons hitting the prostate and the ERB with water only. We describe each dataset, document the full processing chain, and provide the scripts for the statistical analysis.
Collapse
|
31
|
Tessonnier T, Mein S, Walsh DWM, Schuhmacher N, Liew H, Cee R, Galonska M, Scheloske S, Schömers C, Weber U, Brons S, Debus J, Haberer T, Abdollahi A, Mairani A, Dokic I. FLASH dose-rate helium ion beams: first in vitro investigations. Int J Radiat Oncol Biol Phys 2021; 111:1011-1022. [PMID: 34343608 DOI: 10.1016/j.ijrobp.2021.07.1703] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 07/20/2021] [Accepted: 07/22/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To establish and investigate the impact of dose, linear energy transfer (LET) and O2 concentration on biological response to ultra-high dose-rate (uHDR, FLASH) helium ion beams compared to standard dose-rate (SDR) irradiation. METHODS AND MATERIALS Beam delivery settings for raster-scanned helium ions at both uHDR and SDR were tuned to achieve >100 Gy/s and ∼0.1 Gy/s, respectively. For both SDR and uHDR, plan optimization and calibration for 10 × 10mm2 fields was performed to assess in vitro response at LET range of 4.5-16 keV/µm. Clonogenic survival assay was conducted at doses ranging from 2 Gy to 12 Gy in two human lung epithelial cell lines (A549 and H1437). Radiation induced nuclear γH2AX foci (RIF) were assessed in both epithelial cell lines and primary human pulmonary fibroblasts. RESULTS Average dose-rates achieved were 185 Gy/s and 0.12 Gy/s for uHDR and SDR, respectively. No differences in cellular response to SDR vs. uHDR were observed for all tested doses at 21% O2, as well as at 2 and 4 Gy at 1% O2. In contrast, at 1% O2 and dose threshold of ≳8Gy cell survival was higher and correlated with reduced nuclear γH2AX RIF signal indicating FLASH sparing effect in the investigated cell lines irradiated with uHDR as compared to SDR . CONCLUSION The first uHDR delivery of raster-scanned particle beams was achieved using helium ions, reaching FLASH-level dose-rates of >100 Gy/s. Baseline oxygen levels and delivered dose (≳ 8 Gy) play a pivotal role, irrespective of the studied cell lines, for observation of a sparing effect for helium ions.
Collapse
|
32
|
Magalhaes Martins P, Freitas H, Tessonnier T, Ackermann B, Brons S, Seco J. Towards real-time PGS range monitoring in proton therapy of prostate cancer. Sci Rep 2021; 11:15331. [PMID: 34321492 PMCID: PMC8319377 DOI: 10.1038/s41598-021-93612-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 06/24/2021] [Indexed: 11/09/2022] Open
Abstract
Proton therapy of prostate cancer (PCPT) was linked with increased levels of gastrointestinal toxicity in its early use compared to intensity-modulated radiation therapy (IMRT). The higher radiation dose to the rectum by proton beams is mainly due to anatomical variations. Here, we demonstrate an approach to monitor rectal radiation exposure in PCPT based on prompt gamma spectroscopy (PGS). Endorectal balloons (ERBs) are used to stabilize prostate movement during radiotherapy. These ERBs are usually filled with water. However, other water solutions containing elements with higher atomic numbers, such as silicon, may enable the use of PGS to monitor the radiation exposure of the rectum. Protons hitting silicon atoms emit prompt gamma rays with a specific energy of 1.78 MeV, which can be used to monitor whether the ERB is being hit. In a binary approach, we search the silicon energy peaks for every irradiated prostate region. We demonstrate this technique for both single-spot irradiation and real treatment plans. Real-time feedback based on the ERB being hit column-wise is feasible and would allow clinicians to decide whether to adapt or continue treatment. This technique may be extended to other cancer types and organs at risk, such as the oesophagus.
Collapse
|
33
|
Mein S, Tessonnier T, Kopp B, Harrabi S, Abdollahi A, Debus J, Haberer T, Mairani A. Spot-Scanning Hadron Arc (SHArc) Therapy: A Study With Light and Heavy Ions. Adv Radiat Oncol 2021; 6:100661. [PMID: 33817410 PMCID: PMC8010580 DOI: 10.1016/j.adro.2021.100661] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 12/29/2020] [Accepted: 01/18/2021] [Indexed: 12/27/2022] Open
Abstract
PURPOSE To evaluate the clinical potential of spot-scanning hadron arc (SHArc) therapy with a heavy-ion gantry. METHODS AND MATERIALS A series of in silico studies was conducted via treatment plan optimization in FRoG and the RayStation TPS to compare SHArc therapy against reference plans using conventional techniques with single, parallel-opposed, and 3-field configurations for 3 clinical particle beams (protons [p], helium [4He], and carbon [12C] ions). Tests were performed on water-equivalent cylindrical phantoms for simple targets and clinical-like scenarios with an organ-at-risk in proximity of the target. Effective dose and dose-averaged linear energy transfer (LETD) distributions for SHArc were evaluated against conventional planning techniques applying the modified microdosimetric kinetic model for considering bio-effect with (α/β)x = 2 Gy. A model for hypoxia-induced tumor radio-resistance was developed for particle therapy with dependence on oxygen concentration and particle species/energy (Zeff/β)2 to investigate the impact on effective dose. RESULTS SHArc plans exhibited similar target coverage with unique treatment attributes and distributions compared with conventional planning, with carbon ions demonstrating the greatest potential for tumor control and normal tissue sparing among the arc techniques. All SHArc plans exhibited a low-dose bath outside the target volume with a reduced maximum dose in normal tissues compared with single, parallel-opposed, and 3-field configuration plans. Moreover, favorable LETD distributions were made possible using the SHArc approach, with maximum LETD in the r = 5 mm tumor core (~8 keVμm-1, ~30 keVμm-1, and ~150 keVμm-1 for p, 4He, and 12C ions, respectively) and reductions of high-LET regions in normal tissues and organs-at-risk compared with static treatment beam delivery. CONCLUSION SHArc therapy offers potential treatment benefits such as increased normal tissue sparing. Without explicit consideration of oxygen concentration during treatment planning and optimization, SHArc-C may mitigate tumor hypoxia-induced loss of efficacy. Findings justify further development of robust SHArc treatment planning toward potential clinical translation.
Collapse
|
34
|
Kopp B, Mein S, Tessonnier T, Besuglow J, Harrabi S, Heim E, Abdollahi A, Haberer T, Debus J, Mairani A. Rapid effective dose calculation for raster-scanning 4He ion therapy with the modified microdosimetric kinetic model (mMKM). Phys Med 2020; 81:273-284. [PMID: 33353795 DOI: 10.1016/j.ejmp.2020.11.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 11/19/2020] [Accepted: 11/20/2020] [Indexed: 02/07/2023] Open
Abstract
PURPOSE To develop and verify effective dose (DRBE) calculation in 4He ion beam therapy based on the modified microdosimetric kinetic model (mMKM) and evaluate the bio-sensitivity of mMKM-based plans to clinical parameters using a fast analytical dose engine. METHODS Mixed radiation field particle spectra (MRFS) databases have been generated with Monte-Carlo (MC) simulations for 4He-ion beams. Relative biological effectiveness (RBE) and DRBE calculation using MRFS were established within a fast analytical engine. Spread-out Bragg-Peaks (SOBPs) in water were optimized for two dose levels and two tissue types with photon linear-quadratic model parameters αph, βph, and (α/β)ph to verify MRFS-derived database implementation against computations with MC-generated mixed-field α and β databases. Bio-sensitivity of the SOBPs was investigated by varying absolute values of βph, while keeping (α/β)ph constant. Additionally, dose, dose-averaged linear energy transfer, and bio-sensitivity were investigated for two patient cases. RESULTS Using MRFS-derived databases, dose differences ≲2% in the plateau and SOBP are observed compared to computations with MC-generated databases. Bio-sensitivity studies show larger deviations when altering the absolute βph value, with maximum D50% changes of ~5%, with similar results for patient cases. Bio-sensitivity analysis indicates a greater impact on DRBE varying (α/β)ph than βph in mMKM. CONCLUSIONS The MRSF approach yielded negligible differences in the target and small differences in the plateau compared to MC-generated databases. The presented analyses provide guidance for proper implementation of RBE-weighted 4He ion dose prescription and planning with mMKM. The MRFS-DRBE calculation approach using mMKM will be implemented in a clinical treatment planning system.
Collapse
|
35
|
Dokic I, Klein C, Moustafa M, Meister S, Mein S, Kopp B, Tessonnier T, Hasheminasab S, Wei Q, Schlegel J, Nowrouzi A, Schwager C, Mairani A, Zimmermann A, Zenke F, Blaukat A, Debus J, Abdollahi A. Efficient Eradication of NSCLC by Combined DNAPK Inhibition and Carbon Ion Radiotherapy via Modulation of Tumor Invasion and Microenvironment - Beyond Direct Radiosensitization. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.1704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
36
|
Chaikh A, Thariat J, Thureau S, Tessonnier T, Kammerer E, Fontbonne C, Dubray B, Balosso J, Fontbonne J. Construction des modèles radiobiologiques de type TCP (tumor control probability) et NTCP (normal tissue complication probability) : de la dose à la prédiction des effets cliniques. Cancer Radiother 2020; 24:247-257. [DOI: 10.1016/j.canrad.2019.12.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 11/25/2019] [Accepted: 12/04/2019] [Indexed: 12/25/2022]
|
37
|
Bauer J, Tessonnier T, Debus J, Parodi K. Offline imaging of positron emitters induced by therapeutic helium, carbon and oxygen ion beams with a full-ring PET/CT scanner: experiments in reference targets. Phys Med Biol 2019; 64:225016. [PMID: 31561234 DOI: 10.1088/1361-6560/ab48b4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In vivo verification of light ion therapy based on positron-emission tomography (PET) imaging of irradiation induced patient activation relies on activity predictions from Monte-Carlo (MC) or analytical computational engines for comparison to the measurements. In order to achieve the necessary accuracy, experimental data are indispensable for the validation of the calculation models. For this we irradiated thick reference targets with mono-energetic helium, carbon and oxygen ion beams and measured the resulting material activation offline with a commercial full-ring PET/CT scanner located nearby the treatment room. Acquired PET data were analysed over time to separate the activity contribution of different radionuclides. Determined production yields were compared to published findings obtained from in-beam activation measurements with a limited-angle double-head PET camera. In addition, we investigated the time-dependence of the measured radionuclide-specific contributions and of the distal activity range, as well as the lateral spread of the activity signal as a function of beam penetration depth. We present radionuclide-specific depth-resolved activity distributions and production yields for the radionuclides [Formula: see text], [Formula: see text] and [Formula: see text], dominating irradiation-induced patient activation. We observe systematically lower production yields with a ratio between the dual-head and our full-ring PET measurements of, on average, 1.7 and 1.3 for the oxygen and carbon beam irradiations, and 1.7 (2.1) for the high (low) energy helium beam irradiations. Findings on the temporal development of the activity range confirm the expectation, with the oxygen beam induced signal being the most sensitive scenario. The experimental data reported in this work, acquired with a state-of-the-art full ring PET scanner, provide a comprehensive and consistent basis for the benchmarking of PET signal calculation engines. In particular, they can support a fine-tuning of the underlying physics models used by the respective implementation and therefore improve the accuracy of PET-based therapy verifications at current and future treatment facilities.
Collapse
|
38
|
Beddok A, Vela A, Calugaru V, Tessonnier T, Kubes J, Dutheil P, Gérard A, Vidal M, Goudjil F, Florescu C, Kammerer E, Bénézery K, Hérault J, Bourhis J, Thariat J. Protonthérapie des carcinomes épidermoïdes des voies aérodigestives supérieures : de la physique à la clinique. Cancer Radiother 2019. [DOI: 10.1016/j.canrad.2019.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
39
|
Beddok A, Vela A, Calugaru V, Tessonnier T, Kubes J, Dutheil P, Gérard A, Idal M, Goudjil F, Florescu C, Kammerer E, Bénézery K, Hérault J, Bourhis J, Thariat J. Protonthérapie des carcinomes épidermoïdes des voies aérodigestives supérieures : de la physique à la clinique. Cancer Radiother 2019. [DOI: 10.1016/j.canrad.2019.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
40
|
Beddok A, Vela A, Calugaru V, Tessonnier T, Kubes J, Dutheil P, Gérard A, Vidal M, Goudjil F, Florescu C, Kammerer E, Bénézery K, Hérault J, Bourhis J, Thariat J. [Proton therapy for head and neck squamous cell carcinomas: From physics to clinic]. Cancer Radiother 2019; 23:439-448. [PMID: 31358445 DOI: 10.1016/j.canrad.2019.05.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 05/09/2019] [Accepted: 05/16/2019] [Indexed: 11/17/2022]
Abstract
Intensity-modulated radiation therapy (IMRT) is presently the recommended technique for the treatment of locally advanced head and neck carcinomas. Proton therapy would allow to reduce the volume of irradiated normal tissue and, thus, to decrease the risk of late dysphagia, xerostomia, dysgeusia and hypothyroidism. An exhaustive research was performed with the search engine PubMed by focusing on the papers about the physical difficulties that slow down use of proton therapy for head and neck carcinomas. Range uncertainties in proton therapy (±3 %) paradoxically limit the use of the steep dose gradient in distality. Calibration uncertainties can be important in the treatment of head and neck cancer in the presence of materials of uncertain stoichiometric composition (such as with metal implants, dental filling, etc.) and complex heterogeneities. Dental management for example may be different with IMRT or proton therapy. Some uncertainties can be somewhat minimized at the time of optimization. Inter- and intrafractional variations and uncertainties in Hounsfield units/stopping power can be integrated in a robust optimization process. Additional changes in patient's anatomy (tumour shrinkage, changes in skin folds in the beam patch, large weight loss or gain) require rescanning. Dosimetric and small clinical studies comparing photon and proton therapy have well shown the interest of proton therapy for head and neck cancers. Intensity-modulated proton therapy is a promising treatment as it can reduce the substantial toxicity burden of patients with head and neck squamous cell carcinoma compared to IMRT. Robust optimization will allow to perform an optimal treatment and to use proton therapy in current clinical practice.
Collapse
|
41
|
Mein S, Dokic I, Klein C, Tessonnier T, Böhlen TT, Magro G, Bauer J, Ferrari A, Parodi K, Haberer T, Debus J, Abdollahi A, Mairani A. Biophysical modeling and experimental validation of relative biological effectiveness (RBE) for 4He ion beam therapy. Radiat Oncol 2019; 14:123. [PMID: 31296232 PMCID: PMC6624994 DOI: 10.1186/s13014-019-1295-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 05/09/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Helium (4He) ion beam therapy provides favorable biophysical characteristics compared to currently administered particle therapies, i.e., reduced lateral scattering and enhanced biological damage to deep-seated tumors like heavier ions, while simultaneously lessened particle fragmentation in distal healthy tissues as observed with lighter protons. Despite these biophysical advantages, raster-scanning 4He ion therapy remains poorly explored e.g., clinical translational is hampered by the lack of reliable and robust estimation of physical and radiobiological uncertainties. Therefore, prior to the upcoming 4He ion therapy program at the Heidelberg Ion-beam Therapy Center (HIT), we aimed to characterize the biophysical phenomena of 4He ion beams and various aspects of the associated models for clinical integration. METHODS Characterization of biological effect for 4He ion beams was performed in both homogenous and patient-like treatment scenarios using innovative models for estimation of relative biological effectiveness (RBE) in silico and their experimental validation using clonogenic cell survival as the gold-standard surrogate. Towards translation of RBE models in patients, the first GPU-based treatment planning system (non-commercial) for raster-scanning 4He ion beams was devised in-house (FRoG). RESULTS Our data indicate clinically relevant uncertainty of ±5-10% across different model simulations, highlighting their distinct biological and computational methodologies. The in vitro surrogate for highly radio-resistant tissues presented large RBE variability and uncertainty within the clinical dose range. CONCLUSIONS Existing phenomenological and mechanistic/biophysical models were successfully integrated and validated in both Monte Carlo and GPU-accelerated analytical platforms against in vitro experiments, and tested using pristine peaks and clinical fields in highly radio-resistant tissues where models exhibit the greatest RBE uncertainty. Together, these efforts mark an important step towards clinical translation of raster-scanning 4He ion beam therapy to the clinic.
Collapse
|
42
|
Meyer S, Kamp F, Tessonnier T, Mairani A, Belka C, Carlson DJ, Gianoli C, Parodi K. Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning. ACTA ACUST UNITED AC 2019; 64:125008. [DOI: 10.1088/1361-6560/ab0fdf] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
43
|
Balosso J, Thariat J, Habrand J, Tessonnier T, Lesueur P, Chaikh A, Stefan D, Fontbonne J. SP-0642 How to select patients for radiotherapy with protons instead of photons. Radiother Oncol 2019. [DOI: 10.1016/s0167-8140(19)31062-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
44
|
Augusto RS, Bauer J, Bouhali O, Cuccagna C, Gianoli C, Kozłowska WS, Ortega PG, Tessonnier T, Toufique Y, Vlachoudis V, Parodi K, Ferrari A. An overview of recent developments in FLUKA PET tools. Phys Med 2018; 54:189-199. [PMID: 30017561 DOI: 10.1016/j.ejmp.2018.06.636] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 04/25/2018] [Accepted: 06/22/2018] [Indexed: 12/19/2022] Open
Abstract
The new developments of the FLUKA Positron-Emission-Tomography (PET) tools are detailed. FLUKA is a fully integrated Monte Carlo (MC) particle transport code, used for an extended range of applications, including Medical Physics. Recently, it provided the medical community with dedicated simulation tools for clinical applications, including the PET simulation package. PET is a well-established imaging technique in nuclear medicine, and a promising method for clinical in vivo treatment verification in hadrontherapy. The application of clinically established PET scanners to new irradiation environments such as hadrontherapy requires further experimental and theoretical research to which MC simulations could be applied. The FLUKA PET tools, besides featuring PET scanner models in its library, allow the configuration of new PET prototypes via the FLUKA Graphical User Interface (GUI) Flair. Both the beam time structure and scan time can be specified by the user, reproducing PET acquisitions in time, in a particle therapy scenario. Furthermore, different scoring routines allow the analysis of single and coincident events, and identification of parent isotopes generating annihilation events. Two reconstruction codes are currently supported: the Filtered Back-Projection (FBP) and Maximum-Likelihood Expectation Maximization (MLEM), the latter embedded in the tools. Compatibility with other reconstruction frameworks is also possible. The FLUKA PET tools package has been successfully tested for different detectors and scenarios, including conventional functional PET applications and in beam PET, either using radioactive sources, or simulating hadron beam irradiations. The results obtained so far confirm the FLUKA PET tools suitability to perform PET simulations in R&D environment.
Collapse
|
45
|
Mein S, Tessonnier T, Kopp B, Choi K, Haberer T, Debus J, Abdollahi A, Mairani A. EP-1838: FROG: a novel GPU-based approach to the pencil beam algorithm for particle therapy. Radiother Oncol 2018. [DOI: 10.1016/s0167-8140(18)32147-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
46
|
Tessonnier T, Mein S, Kopp B, Choi K, Haberer T, Debus J, Abdollahi A, Mairani A. EP-1851: Evaluation of lateral density heterogeneity handling in a novel GPU-based pencil beam algorithm. Radiother Oncol 2018. [DOI: 10.1016/s0167-8140(18)32160-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
47
|
Puchalska M, Tessonnier T, Parodi K, Sihver L. Benchmarking of PHITS for Carbon Ion Therapy. Int J Part Ther 2018; 4:48-55. [PMID: 31773011 DOI: 10.14338/ijpt-17-00029.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2017] [Accepted: 11/17/2017] [Indexed: 11/21/2022] Open
Abstract
Purpose Up to now, carbon ions have shown the most favorable physical and radiobiological properties for radiation therapy of, for example, deep-seated radioresistant tumors. However, when carbon ions penetrate matter, they undergo inelastic nuclear reactions that give rise to secondary fragments contributing to the dose in the healthy tissue. This can cause damage to radiosensitive organs at risk when they are located in the vicinity of the tumor. Therefore, predictions of the yields and angular distributions of the secondary fragments are needed to be able to estimate the resulting biological effects in both the tumor region and the healthy tissues. This study presents the accuracy of simulations of therapeutic carbon ion beams with water, with the 3D MC (Monte Carlo) general purpose particle and ion transport code PHITS. Materials and Methods Simulations with PHITS of depth-dose distributions, beam attenuation, fragment yields, and fragment angular distributions from interactions of therapeutic carbon ion beams with water are compared to published measurements performed at Gesellschaft für Schwerionen Forschung (GSI). Results The results presented in this study demonstrate that PHITS simulations of therapeutic carbon ion beams in water show overall a good agreement with measurements performed at GSI; for example, for light ions like H and He, simulations agree within about 10%. However, there is still a need to further improve the calculations of fragment yields, especially for underproduction of Li of up to 50%, by improving the nucleus-nucleus cross-section models. Conclusion The simulated data are clinically acceptable but there is still a need to further improve the models in the transport code PHITS. More reliable experimental data are therefore needed.
Collapse
|
48
|
Thariat J, Habrand JL, Lesueur P, Chaikh A, Kammerer E, Lecomte D, Batalla A, Balosso J, Tessonnier T. Apports de la protonthérapie à la radiothérapie d’aujourd’hui, pourquoi, comment ? Bull Cancer 2018; 105:315-326. [DOI: 10.1016/j.bulcan.2017.12.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 12/07/2017] [Accepted: 12/12/2017] [Indexed: 01/06/2023]
|
49
|
Dokic I, Mairani A, Niklas M, Zimmermann F, Chaudhri N, Krunic D, Tessonnier T, Ferrari A, Parodi K, Jäkel O, Debus J, Haberer T, Abdollahi A. Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams. Oncotarget 2018; 7:56676-56689. [PMID: 27494855 PMCID: PMC5302944 DOI: 10.18632/oncotarget.10996] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Accepted: 07/19/2016] [Indexed: 12/22/2022] Open
Abstract
The growing number of particle therapy facilities worldwide landmarks a novel era of precision oncology. Implementation of robust biophysical readouts is urgently needed to assess the efficacy of different radiation qualities. This is the first report on biophysical evaluation of Monte Carlo simulated predictive models of prescribed dose for four particle qualities i.e., proton, helium-, carbon- or oxygen ions using raster-scanning technology and clinical therapy settings at HIT. A high level of agreement was found between the in silico simulations, the physical dosimetry and the clonogenic tumor cell survival. The cell fluorescence ion track hybrid detector (Cell-Fit-HD) technology was employed to detect particle traverse per cell nucleus. Across a panel of radiobiological surrogates studied such as late ROS accumulation and apoptosis (caspase 3/7 activation), the relative biological effectiveness (RBE) chiefly correlated with the radiation species-specific spatio-temporal pattern of DNA double strand break (DSB) formation and repair kinetic. The size and the number of residual nuclear γ-H2AX foci increased as a function of linear energy transfer (LET) and RBE, reminiscent of enhanced DNA-damage complexity and accumulation of non-repairable DSB. These data confirm the high relevance of complex DSB formation as a central determinant of cell fate and reliable biological surrogates for cell survival/ RBE. The multi-scale simulation, physical and radiobiological characterization of novel clinical quality beams presented here constitutes a first step towards development of high precision biologically individualized radiotherapy.
Collapse
|
50
|
Tessonnier T, Mairani A, Chen W, Sala P, Cerutti F, Ferrari A, Haberer T, Debus J, Parodi K. Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison. Radiat Oncol 2018; 13:2. [PMID: 29316969 PMCID: PMC5759862 DOI: 10.1186/s13014-017-0944-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Accepted: 12/14/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Due to their favorable physical and biological properties, helium ion beams are increasingly considered a promising alternative to proton beams for radiation therapy. Hence, this work aims at comparing in-silico the treatment of brain and ocular meningiomas with protons and helium ions, using for the first time a dedicated Monte Carlo (MC) based treatment planning engine (MCTP) thoroughly validated both in terms of physical and biological models. METHODS Starting from clinical treatment plans of four patients undergoing proton therapy with a fixed relative biological effectiveness (RBE) of 1.1 and a fraction dose of 1.8 Gy(RBE), new treatment plans were optimized with MCTP for both protons (with variable and fixed RBE) and helium ions (with variable RBE) under the same constraints derived from the initial clinical plans. The resulting dose distributions were dosimetrically compared in terms of dose volume histograms (DVH) parameters for the planning target volume (PTV) and the organs at risk (OARs), as well as dose difference maps. RESULTS In most of the cases helium ion plans provided a similar PTV coverage as protons with a consistent trend of superior OAR sparing. The latter finding was attributed to the ability of helium ions to offer sharper distal and lateral dose fall-offs, as well as a more favorable differential RBE variation in target and normal tissue. CONCLUSIONS Although more studies are needed to investigate the clinical potential of helium ions for different tumour entities, the results of this work based on an experimentally validated MC engine support the promise of this modality with state-of-the-art pencil beam scanning delivery, especially in case of tumours growing in close proximity of multiple OARs such as meningiomas.
Collapse
|