26
|
Nordseth T, Niles DE, Eftestøl T, Sutton RM, Irusta U, Abella BS, Berg RA, Nadkarni VM, Skogvoll E. Rhythm characteristics and patterns of change during cardiopulmonary resuscitation for in-hospital paediatric cardiac arrest. Resuscitation 2019; 135:45-50. [PMID: 30639791 DOI: 10.1016/j.resuscitation.2019.01.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 12/05/2018] [Accepted: 01/03/2019] [Indexed: 11/29/2022]
Abstract
During paediatric cardiopulmonary resuscitation (CPR), patients may transition between pulseless electrical activity (PEA), asystole, ventricular fibrillation/tachycardia (VF/VT), and return of spontaneous circulation (ROSC). The aim of this study was to quantify the dynamic characteristics of this process. METHODS ECG recordings were collected in patients who received CPR at the Children's Hospital of Philadelphia (CHOP) between 2006 and 2013. Transitions between PEA (including bradycardia with poor perfusion), VF/VT, asystole, and ROSC were quantified by applying a multi-state statistical model with competing risks, and by smoothing the Nelson-Aalen estimator of cumulative hazard. RESULTS Seventy-four episodes of cardiac arrest were included. Median age of patients was 15 years [IQR 11-17], 50% were female and 62% had a respiratory aetiology of arrest. Presenting cardiac arrest rhythms were PEA (60%), VF/VT (24%) and asystole (16%). A temporary surge of PEA was observed between 10 and 15 min due to a doubling of the transition rate from ROSC to PEA (i.e. 're-arrests'). The prevalence of sustained ROSC reached an asymptotic value of 30% at 20 min. Simulation suggests that doubling the transition rate from PEA to ROSC and halving the relapse rate might increase the prevalence of sustained ROSC to 50%. CONCLUSION Children and adolescents who received CPR were prone to re-arrest between 10 and 15 min after start of CPR efforts. If the rate of PEA to ROSC transition could be increased and the rate of re-arrests reduced, the overall survival rate may improve.
Collapse
|
27
|
Aramendi E, Lu Y, Chang MP, Elola A, Irusta U, Owens P, Idris AH. A novel technique to assess the quality of ventilation during pre-hospital cardiopulmonary resuscitation. Resuscitation 2018; 132:41-46. [DOI: 10.1016/j.resuscitation.2018.08.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Revised: 07/19/2018] [Accepted: 08/13/2018] [Indexed: 10/28/2022]
|
28
|
Isasi I, Irusta U, Elola A, Aramendi E, Ayala U, Alonso E, Kramer-Johansen J, Eftestol T. A Machine Learning Shock Decision Algorithm for Use During Piston-Driven Chest Compressions. IEEE Trans Biomed Eng 2018; 66:1752-1760. [PMID: 30387719 DOI: 10.1109/tbme.2018.2878910] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
GOAL Accurate shock decision methods during piston-driven cardiopulmonary resuscitation (CPR) would contribute to improve therapy and increase cardiac arrest survival rates. The best current methods are computationally demanding, and their accuracy could be improved. The objective of this work was to introduce a computationally efficient algorithm for shock decision during piston-driven CPR with increased accuracy. METHODS The study dataset contains 201 shockable and 844 nonshockable ECG segments from 230 cardiac arrest patients treated with the LUCAS-2 mechanical CPR device. Compression artifacts were removed using the state-of-the-art adaptive filters, and shock/no-shock discrimination features were extracted from the stationary wavelet transform analysis of the filtered ECG, and fed to a support vector machine (SVM) classifier. Quasi-stratified patient wise nested cross-validation was used for feature selection and SVM hyperparameter optimization. The procedure was repeated 50 times to statistically characterize the results. RESULTS Best results were obtained for a six-feature classifier with mean (standard deviation) sensitivity, specificity, and total accuracy of 97.5 (0.4), 98.2 (0.4), and 98.1 (0.3), respectively. The algorithm presented a five-fold reduction in computational demands when compared to the best available methods, while improving their balanced accuracy by 3 points. CONCLUSIONS The accuracy of the best available methods was improved while drastically reducing the computational demands. SIGNIFICANCE An efficient and accurate method for shock decisions during mechanical CPR is now available to improve therapy and contribute to increase cardiac arrest survival.
Collapse
|
29
|
Elola A, Aramendi E, Irusta U, Del Ser J, Alonso E, Daya M. ECG-based pulse detection during cardiac arrest using random forest classifier. Med Biol Eng Comput 2018; 57:453-462. [PMID: 30215212 DOI: 10.1007/s11517-018-1892-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Accepted: 08/29/2018] [Indexed: 10/28/2022]
Abstract
Sudden cardiac arrest is one of the leading causes of death in the industrialized world. Pulse detection is essential for the recognition of the arrest and the recognition of return of spontaneous circulation during therapy, and it is therefore crucial for the survival of the patient. This paper introduces the first method based exclusively on the ECG for the automatic detection of pulse during cardiopulmonary resuscitation. Random forest classifier is used to efficiently combine up to nine features from the time, frequency, slope, and regularity analysis of the ECG. Data from 191 cardiac arrest patients was used, and 1177 ECG segments were processed, 796 with pulse and 381 without pulse. A leave-one-patient out cross validation approach was used to train and test the algorithm. The statistical distributions of sensitivity (SE) and specificity (SP) for pulse detection were estimated using 500 patient-wise bootstrap partitions. The mean (std) SE/SP for nine-feature classifier was 88.4 (1.8) %/89.7 (1.4) %, respectively. The designed algorithm only requires 4-s-long ECG segments and could be integrated in any commercial automated external defibrillator. The method permits to detect the presence of pulse accurately, minimizing interruptions in cardiopulmonary resuscitation therapy, and could contribute to improve survival from cardiac arrest.
Collapse
|
30
|
Eftestøl T, Stokka SE, Kvaløy JT, Rad AB, Irusta U, Aramendi E, Alonso E, Nordseth T, Skogvoll E, Wik L, Kramer-Johansen J. A machine learning approach to model a probabilistic relationship between parameters reflecting quality of chest compressions and physiological response during out-of-hospital cardiopulmonary resuscitation. Resuscitation 2018. [DOI: 10.1016/j.resuscitation.2018.07.354] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Isasi I, Irusta U, Aramendi E, Olsen JÅ, Wik L. Removing mechanical chest compression artefacts induced by a load distributing band device from the ECG. Resuscitation 2018. [DOI: 10.1016/j.resuscitation.2018.07.069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
32
|
Alonso E, Aramendi E, Irusta U, Daya M. A machine learning approach for detecting ventricular fibrillation during out-of-hospital cardiac arrest. Resuscitation 2018. [DOI: 10.1016/j.resuscitation.2018.07.096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
33
|
Larrea A, Salaberria R, Alonso D, Irusta U, Aramendi E, Isasi I, Lerma AM, García MJ, Férnandez C, Veliz D, Molina I. Monitoring chest compression rate using cerebral oximetry. Resuscitation 2018. [DOI: 10.1016/j.resuscitation.2018.07.241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
34
|
Salaberria R, Larrea A, Alonso D, Aramendi E, Irusta U, Ortega JI, Fernandez-Barrera E, Virtus I, Arruebarrena JP, Ramos A. Evaluation of the increase in cerebral oximeter saturation during out-of-hospital mechanical chest compression sequences. Resuscitation 2018. [DOI: 10.1016/j.resuscitation.2018.07.220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
35
|
Chicote B, Irusta U, Aramendi E, Alcaraz R, Rieta JJ, Isasi I, Alonso D, Baqueriza MDM, Ibarguren K. Fuzzy and Sample Entropies as Predictors of Patient Survival Using Short Ventricular Fibrillation Recordings during out of Hospital Cardiac Arrest. ENTROPY (BASEL, SWITZERLAND) 2018; 20:E591. [PMID: 33265680 PMCID: PMC7513119 DOI: 10.3390/e20080591] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 08/04/2018] [Accepted: 08/07/2018] [Indexed: 12/23/2022]
Abstract
Optimal defibrillation timing guided by ventricular fibrillation (VF) waveform analysis would contribute to improved survival of out-of-hospital cardiac arrest (OHCA) patients by minimizing myocardial damage caused by futile defibrillation shocks and minimizing interruptions to cardiopulmonary resuscitation. Recently, fuzzy entropy (FuzzyEn) tailored to jointly measure VF amplitude and regularity has been shown to be an efficient defibrillation success predictor. In this study, 734 shocks from 296 OHCA patients (50 survivors) were analyzed, and the embedding dimension (m) and matching tolerance (r) for FuzzyEn and sample entropy (SampEn) were adjusted to predict defibrillation success and patient survival. Entropies were significantly larger in successful shocks and in survivors, and when compared to the available methods, FuzzyEn presented the best prediction results, marginally outperforming SampEn. The sensitivity and specificity of FuzzyEn were 83.3% and 76.7% when predicting defibrillation success, and 83.7% and 73.5% for patient survival. Sensitivities and specificities were two points above those of the best available methods, and the prediction accuracy was kept even for VF intervals as short as 2s. These results suggest that FuzzyEn and SampEn may be promising tools for optimizing the defibrillation time and predicting patient survival in OHCA patients presenting VF.
Collapse
|
36
|
Isasi I, Irusta U, Aramendi E, Ayala U, Alonso E, Kramer-Johansen J, Eftestol T. A Multistage Algorithm for ECG Rhythm Analysis During Piston-Driven Mechanical Chest Compressions. IEEE Trans Biomed Eng 2018; 66:263-272. [PMID: 29993407 DOI: 10.1109/tbme.2018.2827304] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
GOAL An accurate rhythm analysis during cardiopulmonary resuscitation (CPR) would contribute to increase the survival from out-of-hospital cardiac arrest. Piston-driven mechanical compression devices are frequently used to deliver CPR. The objective of this paper was to design a method to accurately diagnose the rhythm during compressions delivered by a piston-driven device. METHODS Data was gathered from 230 out-of-hospital cardiac arrest patients treated with the LUCAS 2 mechanical CPR device. The dataset comprised 201 shockable and 844 nonshockable ECG segments, whereof 270 were asystole (AS) and 574 organized rhythm (OR). A multistage algorithm (MSA) was designed, which included two artifact filters based on a recursive least squares algorithm, a rhythm analysis algorithm from a commercial defibrillator, and an ECG-slope-based rhythm classifier. Data was partitioned randomly and patient-wise into training (60%) and test (40%) for optimization and validation, and statistically meaningful results were obtained repeating the process 500 times. RESULTS The mean (standard deviation) sensitivity (SE) for shockable rhythms, specificity (SP) for nonshockable rhythms, and the total accuracy of the MSA solution were: 91.7 (6.0), 98.1 (1.1), and 96.9 (0.9), respectively. The SP for AS and OR were 98.0 (1.7) and 98.1 (1.4), respectively. CONCLUSIONS The SE/SP were above the 90%/95% values recommended by the American Heart Association for shockable and nonshockable rhythms other than sinus rhythm, respectively. SIGNIFICANCE It is possible to accurately diagnose the rhythm during mechanical chest compressions and the results considerably improve those obtained by previous algorithms.
Collapse
|
37
|
Alonso E, Aramendi E, Irusta U, Daya M, Corcuera C, Lu Y, Idris AH. Evaluation of chest compression artefact removal based on rhythm assessments made by clinicians. Resuscitation 2018; 125:104-110. [DOI: 10.1016/j.resuscitation.2018.01.056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Revised: 01/11/2018] [Accepted: 01/31/2018] [Indexed: 10/18/2022]
|
38
|
Corcuera C, Galdos G, Olabarria M, Veintemillas J, Larrea A, Bastida JM, Ibarguren K, Alonso D, Chicote B, Aramendi E, Irusta U. Assessment of the diagnoses of automated external defibrillators operated by basic life support personnel. Resuscitation 2017. [DOI: 10.1016/j.resuscitation.2017.08.227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
39
|
Chicote B, Aramendi E, Irusta U, Alonso E, Elola A, Owens P, Idris A. Analysis of the end-tidal CO2 as shock outcome predictor in out-of-hospital cardiac arrest. Resuscitation 2017. [DOI: 10.1016/j.resuscitation.2017.08.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
40
|
Galdos G, Olabarria M, Veintemillas J, Corcuera C, Bastida JM, Larrea A, Alonso D, Ibarguren K, Chicote B, Aramendi E, Irusta U. Challenges for clinicians in ECG based retrospective resuscitation rhythm annotation. Resuscitation 2017. [DOI: 10.1016/j.resuscitation.2017.08.121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
41
|
Isasi I, Irusta U, Aramendi E, Age J, Wik L. Characterization of the ECG compression artefact caused by the AutoPulse device. Resuscitation 2017. [DOI: 10.1016/j.resuscitation.2017.08.099] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
42
|
Rad AB, Eftestol T, Engan K, Irusta U, Kvaloy JT, Kramer-Johansen J, Wik L, Katsaggelos AK. ECG-Based Classification of Resuscitation Cardiac Rhythms for Retrospective Data Analysis. IEEE Trans Biomed Eng 2017; 64:2411-2418. [PMID: 28371771 DOI: 10.1109/tbme.2017.2688380] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE There is a need to monitor the heart rhythm in resuscitation to improve treatment quality. Resuscitation rhythms are categorized into: ventricular tachycardia (VT), ventricular fibrillation (VF), pulseless electrical activity (PEA), asystole (AS), and pulse-generating rhythm (PR). Manual annotation of rhythms is time-consuming and infeasible for large datasets. Our objective was to develop ECG-based algorithms for the retrospective and automatic classification of resuscitation cardiac rhythms. METHODS The dataset consisted of 1631 3-s ECG segments with clinical rhythm annotations, obtained from 298 out-of-hospital cardiac arrest patients. In total, 47 wavelet- and time-domain-based features were computed from the ECG. Features were selected using a wrapper-based feature selection architecture. Classifiers based on Bayesian decision theory, k-nearest neighbor, k-local hyperplane distance nearest neighbor, artificial neural network (ANN), and ensemble of decision trees were studied. RESULTS The best results were obtained for ANN classifier with Bayesian regularization backpropagation training algorithm with 14 features, which forms the proposed algorithm. The overall accuracy for the proposed algorithm was 78.5%. The sensitivities (and positive-predictive-values) for AS, PEA, PR, VF, and VT were 88.7% (91.0%), 68.9% (70.4%), 65.9% (69.0%), 86.2% (83.8%), and 78.8% (72.9%), respectively. CONCLUSIONS The results demonstrate that it is possible to classify resuscitation cardiac rhythms automatically, but the accuracy for the organized rhythms (PEA and PR) is low. SIGNIFICANCE We have made an important step toward making classification of resuscitation rhythms more efficient in the sense of minimal feedback from human experts.
Collapse
|
43
|
Aramendi E, Elola A, Alonso E, Irusta U, Daya M, Russell JK, Hubner P, Sterz F. Feasibility of the capnogram to monitor ventilation rate during cardiopulmonary resuscitation. Resuscitation 2017; 110:162-168. [DOI: 10.1016/j.resuscitation.2016.08.033] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Revised: 07/27/2016] [Accepted: 08/09/2016] [Indexed: 10/21/2022]
|
44
|
Figuera C, Irusta U, Morgado E, Aramendi E, Ayala U, Wik L, Kramer-Johansen J, Eftestøl T, Alonso-Atienza F. Machine Learning Techniques for the Detection of Shockable Rhythms in Automated External Defibrillators. PLoS One 2016; 11:e0159654. [PMID: 27441719 PMCID: PMC4956226 DOI: 10.1371/journal.pone.0159654] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Accepted: 07/05/2016] [Indexed: 01/08/2023] Open
Abstract
Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s.
Collapse
|
45
|
Rad AB, Engan K, Katsaggelos AK, Kvaløy JT, Wik L, Kramer-Johansen J, Irusta U, Eftestøl T. Automatic cardiac rhythm interpretation during resuscitation. Resuscitation 2016; 102:44-50. [DOI: 10.1016/j.resuscitation.2016.01.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 12/27/2015] [Accepted: 01/15/2016] [Indexed: 10/22/2022]
|
46
|
Aramendi E, Irusta U. To interrupt, or not to interrupt chest compressions for ventilation: that is the question! J Thorac Dis 2016; 8:E121-3. [PMID: 26904239 PMCID: PMC4740154 DOI: 10.3978/j.issn.2072-1439.2016.01.04] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
47
|
Alonso E, Aramendi E, Daya M, Irusta U, Chicote B, Russell JK, Tereshchenko LG. Circulation detection using the electrocardiogram and the thoracic impedance acquired by defibrillation pads. Resuscitation 2015; 99:56-62. [PMID: 26705970 DOI: 10.1016/j.resuscitation.2015.11.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Revised: 10/06/2015] [Accepted: 11/22/2015] [Indexed: 11/25/2022]
Abstract
AIM To develop and evaluate a method to detect circulation in the presence of organized rhythms (ORs) during resuscitation using signals acquired by defibrillation pads. METHODS Segments containing electrocardiogram (ECG) and thoracic impedance (TI) signals free of artifacts were used. The ECG corresponded to ORs classified as pulseless electrical activity (PEA) or pulse-generating rhythm (PR). A first dataset containing 1091 segments was split into training and test sets to develop and validate the circulation detector. The method processed ECG and TI to obtain the impedance circulation component (ICC). Morphological features were extracted from ECG and ICC, and combined into a classifier to discriminate between PEA and PR. The performance of the method was evaluated in terms of sensitivity (PR) and specificity (PEA). A second dataset (86 segments from different patients) was used to assess two application of the method: confirmation of arrest by recognizing absence of circulation during ORs and detection of return of spontaneous circulation (ROSC) during resuscitation. In both cases, time to confirmation of arrest/ROSC was determined. RESULTS The method showed a sensitivity/specificity of 92.1%/90.3% and 92.2%/91.9% for training and test sets respectively. The method confirmed cardiac arrest with a specificity of 93.3% with a median delay of 0s after the first OR annotation. ROSC was detected with a sensitivity of 94.4% with a median delay of 57s from ROSC onset. CONCLUSION The method showed good performance, and can be reliably used to distinguish perfusing from non-perfusing ORs.
Collapse
|
48
|
Alonso D, Vaqueriza I, Corcuera C, Vicente F, Aramendi E, Irusta U, Chicote B. Quality of chest compressions for EMT CPR in the Basque Autonomous Community. Resuscitation 2015. [DOI: 10.1016/j.resuscitation.2015.09.169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
49
|
Ibarguren K, Unanue JM, Alonso D, Vaqueriza I, Irusta U, Aramendi E, Chicote B. Difference in survival from pre-hospital cardiac arrest between cities and villages in the Basque Autonomous Community. Resuscitation 2015. [DOI: 10.1016/j.resuscitation.2015.09.269] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
50
|
Chicote B, Irusta U, Aramendi E, Bastida JM, Veintemillas J, Larrea A, Ibarguren K. Evolution of AMSA for shock success prediction during the pre-shock pause. Resuscitation 2015. [DOI: 10.1016/j.resuscitation.2015.09.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|