26
|
Kohagura J, Yoshikawa M, Wang X, Kuwahara D, Ito N, Nagayama Y, Shima Y, Nojiri K, Sakamoto M, Nakashima Y, Mase A. A 60-GHz interferometer with a local oscillator integrated antenna array for divertor simulation experiments on GAMMA 10/PDX. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E127. [PMID: 27910479 DOI: 10.1063/1.4961292] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In conventional multichannel/imaging microwave diagnostics of interferometry, reflectometry, and electron cyclotron emission measurements, a local oscillator (LO) signal is commonly supplied to a receiver array via irradiation using LO optics. In this work, we present a 60-GHz interferometer with a new eight-channel receiver array, called a local oscillator integrated antenna array (LIA). An outstanding feature of LIA is that it incorporates a frequency quadrupler integrated circuit for LO supply to each channel. This enables simple and uniform LO supply to the receiver array using only a 15-GHz LO source and a coaxial cable transmission line instead of using an expensive 60-GHz source, LO optics, and a waveguide transmission line. The new interferometer system is first applied to measure electron line-averaged density inside the divertor simulation experimental module (D-module) on GAMMA 10/PDX tandem mirror device.
Collapse
|
27
|
Ohta K, Yoshikawa M, Yasuhara R, Chikatsu M, Shima Y, Kohagura J, Sakamoto M, Nakasima Y, Imai T, Ichimura M, Yamada I, Funaba H, Minami T. Analysis method for Thomson scattering diagnostics in GAMMA 10/PDX. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E730. [PMID: 27910340 DOI: 10.1063/1.4963161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We have developed an analysis method to improve the accuracies of electron temperature measurement by employing a fitting technique for the raw Thomson scattering (TS) signals. Least square fitting of the raw TS signals enabled reduction of the error in the electron temperature measurement. We applied the analysis method to a multi-pass (MP) TS system. Because the interval between the MPTS signals is very short, it is difficult to separately analyze each Thomson scattering signal intensity by using the raw signals. We used the fitting method to obtain the original TS scattering signals from the measured raw MPTS signals to obtain the electron temperatures in each pass.
Collapse
|
28
|
Morita T, Shima Y, Kakigano A, Ogata A, Kumanogoh A. Serum anti-citrullinated protein antibodies of a mother with rheumatoid arthritis pass through the placenta but do not cause arthritis in her neonate. Scand J Rheumatol 2016; 46:85-86. [PMID: 27574903 DOI: 10.1080/03009742.2016.1195871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
29
|
Steinmetz CC, Tatavarty V, Sugino K, Shima Y, Joseph A, Lin H, Rutlin M, Lambo M, Hempel CM, Okaty BW, Paradis S, Nelson SB, Turrigiano GG. Upregulation of μ3A Drives Homeostatic Plasticity by Rerouting AMPAR into the Recycling Endosomal Pathway. Cell Rep 2016; 16:2711-2722. [PMID: 27568566 DOI: 10.1016/j.celrep.2016.08.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2014] [Revised: 07/15/2016] [Accepted: 08/01/2016] [Indexed: 01/06/2023] Open
Abstract
Synaptic scaling is a form of homeostatic plasticity driven by transcription-dependent changes in AMPA-type glutamate receptor (AMPAR) trafficking. To uncover the pathways involved, we performed a cell-type-specific screen for transcripts persistently altered during scaling, which identified the μ subunit (μ3A) of the adaptor protein complex AP-3A. Synaptic scaling increased μ3A (but not other AP-3 subunits) in pyramidal neurons and redistributed dendritic μ3A and AMPAR to recycling endosomes (REs). Knockdown of μ3A prevented synaptic scaling and this redistribution, while overexpression (OE) of full-length μ3A or a truncated μ3A that cannot interact with the AP-3A complex was sufficient to drive AMPAR to REs. Finally, OE of μ3A acted synergistically with GRIP1 to recruit AMPAR to the dendritic membrane. These data suggest that excess μ3A acts independently of the AP-3A complex to reroute AMPAR to RE, generating a reservoir of receptors essential for the regulated recruitment to the synaptic membrane during scaling up.
Collapse
|
30
|
Aoyagi S, Matsumoto T, Shima Y, Ishikawa T. Usefulness of SDS-Minislab Method in Electrophoretic Analyses of Photographic Gelatin. ACTA ACUST UNITED AC 2016. [DOI: 10.1080/00223638.1987.11738456] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
31
|
Shima Y, Sugino K, Hempel CM, Shima M, Taneja P, Bullis JB, Mehta S, Lois C, Nelson SB. A Mammalian enhancer trap resource for discovering and manipulating neuronal cell types. eLife 2016; 5:e13503. [PMID: 26999799 PMCID: PMC4846381 DOI: 10.7554/elife.13503] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Accepted: 03/18/2016] [Indexed: 12/16/2022] Open
Abstract
There is a continuing need for driver strains to enable cell-type-specific manipulation in the nervous system. Each cell type expresses a unique set of genes, and recapitulating expression of marker genes by BAC transgenesis or knock-in has generated useful transgenic mouse lines. However, since genes are often expressed in many cell types, many of these lines have relatively broad expression patterns. We report an alternative transgenic approach capturing distal enhancers for more focused expression. We identified an enhancer trap probe often producing restricted reporter expression and developed efficient enhancer trap screening with the PiggyBac transposon. We established more than 200 lines and found many lines that label small subsets of neurons in brain substructures, including known and novel cell types. Images and other information about each line are available online (enhancertrap.bio.brandeis.edu). DOI:http://dx.doi.org/10.7554/eLife.13503.001 Scientists can track and even alter the activity of different kinds of neurons, as well as the connections between neurons, by manipulating their genes. However, most genes are active in many different kinds of cells in many different places in the brain, making it difficult to track or target only a particular neuron or brain area. Enhancers are sections of DNA that can regulate the activity of nearby genes so that they are only active in very specific cell types, and an “enhancer trap” is a genetic approach that essentially hijacks enhancers to express artificial genes in those same cell types. The technique relies on inserting a genetic marker, which can be easily tracked, into random locations in the genome. If this marker then interacts with an enhancer, it is activated and the effect of the enhancer on gene expression can be assessed. This method has been used in fruit flies and fish to identify enhancers that specifically restrict gene expression to a small subset of cells. Now, Shima et al. show that enhancer traps can be used successfully in mammals too. The experiments produced over 200 different strains of mice, many with the fluorescent marker only in specific brain areas or in specific kinds of brain cells. Some of the types of brain cells uncovered by these experiments are new, and the labelling of specific brain cells and brain areas in different strains makes these mice a useful resource for future work. Furthermore, it will be relatively straightforward to produce many more strains of these mice, because it would simply involve crossbreeding mice. It is likely that some of these to-be-discovered strains will be useful tools for research as well. DOI:http://dx.doi.org/10.7554/eLife.13503.002
Collapse
|
32
|
Tanaka M, Ueda K, Kawazoe Y, Yonemitsu T, Kida M, Shima Y, Yamazoe S, Iwasaki Y, Kato S. A retrospective investigation of the pmx-dhp's efficacy in 88 severe sepsis cases. Intensive Care Med Exp 2015. [PMCID: PMC4798343 DOI: 10.1186/2197-425x-3-s1-a794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
33
|
Okada T, Ikezoe R, Ichimura M, Hirata M, Yokoyama T, Iwamoto Y, Sumida S, Takeyama K, Jang S, Yoshikawa M, Kohagura J, Shima Y. Internal Measurement of Propagation of ICRF Waves by Using Reflectometers on GAMMA 10. FUSION SCIENCE AND TECHNOLOGY 2015. [DOI: 10.13182/fst14-898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
34
|
Yoshikawa M, Yasuhara R, Nagasu K, Shimamura Y, Shima Y, Kohagura J, Sakamoto M, Nakashima Y, Imai T, Ichimura M, Yamada I, Funaba H, Kawahata K, Minami T. First results of electron temperature measurements by the use of multi-pass Thomson scattering system in GAMMA 10. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:11D801. [PMID: 25430214 DOI: 10.1063/1.4885542] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A multi-pass Thomson scattering (TS) has the advantage of enhancing scattered signals. We constructed a multi-pass TS system for a polarisation-based system and an image relaying system modelled on the GAMMA 10 TS system. We undertook Raman scattering experiments both for the multi-pass setting and for checking the optical components. Moreover, we applied the system to the electron temperature measurements in the GAMMA 10 plasma for the first time. The integrated scattering signal was magnified by approximately three times by using the multi-pass TS system with four passes. The electron temperature measurement accuracy is improved by using this multi-pass system.
Collapse
|
35
|
Hosokawa K, Yamazaki H, Nakamura T, Yoroidaka T, Imi T, Shima Y, Ohata K, Takamatsu H, Kotani T, Kondo Y, Takami A, Nakao S. Successful hyperbaric oxygen therapy for refractory BK virus-associated hemorrhagic cystitis after cord blood transplantation. Transpl Infect Dis 2014; 16:843-6. [PMID: 25040402 DOI: 10.1111/tid.12266] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2013] [Revised: 02/20/2014] [Accepted: 04/21/2014] [Indexed: 11/30/2022]
Abstract
BK virus-associated hemorrhagic cystitis (BKV-HC) is a common and major cause of morbidity in recipients of allogeneic hematopoietic stem cell transplantation. A 32-year-old woman developed severe BKV-HC on day 24 after cord blood transplantation (CBT). Despite supportive therapies - such as hyperhydration, forced diuresis, and urinary catheterization - macroscopic hematuria and bladder irritation persisted for over a month. Hyperbaric oxygen (HBO) therapy at 2.1 atmospheres for 90 min per day was started on day 64 after CBT. Macroscopic hematuria resolved within a week, and microscopic hematuria was no longer detectable within 2 weeks. Hematuria did not recur after 11 sessions of HBO therapy, and no significant side effects were observed during or after treatment. HBO therapy could thus be useful in controlling refractory BKV-HC after CBT.
Collapse
|
36
|
Yoshida Y, Ogata A, Tomita T, Kang S, Hirano T, Shima Y, Narazaki M, Tanaka T, Kumanogoh A. AB0156 Increased Soluble Semaphorin 4D in Rheumatoid Arthritis. Ann Rheum Dis 2014. [DOI: 10.1136/annrheumdis-2014-eular.3513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
37
|
Shima Y, Kitaoka K, Nakase J, Goshima K, Takahashi R, Toratani T, Kosaka M, Ohashi Y, Tsuchiya H, Munehiro T, Aiba T. YOUNG FEMALE ATHLETES HAVE CHANGED CONSIDERABLY IN THE TWO YEARS AFTER BASELINE EVALUATION IN A PROSPECTIVE STUDY. Br J Sports Med 2014. [DOI: 10.1136/bjsports-2014-093494.269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
38
|
Shinozaki K, Tanda S, Shima Y, Yomiya K, Matoba M, Adachi I, Yoshimoto T, Eguchi K, Goto F. A Randomized, Double-Blind, Placebo-Controlled PIII Study of Fentanyl Buccal Tablet (FBT) for Breakthrough Cancer Pain. Ann Oncol 2013. [DOI: 10.1093/annonc/mdt459.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
39
|
Yamaguchi T, Shima Y, Morita T, Hosoya M, Matoba M. Clinical Guideline for Pharmacological Management of Cancer Pain: The Japanese Society of Palliative Medicine Recommendations. Jpn J Clin Oncol 2013; 43:896-909. [DOI: 10.1093/jjco/hyt099] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
40
|
Hashiba T, Shimizu K, Shima Y, Kobayashi T. What is the factor for affecting the period of the conservative therapy in frozen shoulder? Hong Kong Physiother J 2013. [DOI: 10.1016/j.hkpj.2013.01.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
41
|
Yoshida Y, Kang S, Morishima A, Akihiko N, Hishitani Y, Maeda Y, Nishide M, Hamano M, Morimoto K, Hirano T, Shima Y, Narazaki M, Tanaka T, Ogata A, Kumanogoh A. AB0114 Semaphorin3a and semaphorin4d in rheumatoid arthritis. Ann Rheum Dis 2013. [DOI: 10.1136/annrheumdis-2013-eular.2437] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
42
|
Akita D, Yoshikawa M, Sakamoto M, Kohagura J, Shima Y, Yamada T, Morikawa Y, Hasegawa Y, Imai T. Improvement of Measurement Accuracy of the Phase Imaging Interferometer in GAMMA 10. FUSION SCIENCE AND TECHNOLOGY 2013. [DOI: 10.13182/fst13-a16946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
43
|
Sato T, Ikezoe R, Ichimura M, Hirata M, Yokoyama T, Ugajin Y, Iimura T, Saito Y, Annaka Y, Shiratani A, Shima Y, Kohagura J, Yoshikawa M, Imai T. Two-Point Measurement of High-Frequency Density Fluctuations by Reflectometry in GAMMA 10. FUSION SCIENCE AND TECHNOLOGY 2013. [DOI: 10.13182/fst13-a16944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
44
|
Yoshikawa M, Morimoto M, Shima Y, Kohagura J, Sakamoto M, Yamada I, Yasuhara R, Kawahata K, Funaba H, Minami T, Nakashima Y, Ichimura M, Minami R, Hosoi K, Kitade S, Kawarasaki R, Kobayashi S, Mizuuchi T, Imai T. Electron Temperature and Density Measurements by Using Thomson Scattering System in GAMMA 10. FUSION SCIENCE AND TECHNOLOGY 2013. [DOI: 10.13182/fst13-a16887] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
45
|
Hasegawa Y, Yoshikawa M, Kohagura J, Sakamoto M, Shima Y, Akita D, Morikawa Y, Ichimura M, Imai T. Radial Electron Density Measurement by Using a Multi-Channel Microwave Interferometer in the Tandem Mirror GAMMA 10. FUSION SCIENCE AND TECHNOLOGY 2013. [DOI: 10.13182/fst13-a16947] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
46
|
Morikawa Y, Yoshikawa M, Kohagura J, Shima Y, Hasegawa Y, Akita D, Sakamoto M, Imai T. Density Fluctuation Measurements of the GAMMA 10 Plasma by Using the Fraunhofer Diffraction Method. FUSION SCIENCE AND TECHNOLOGY 2013. [DOI: 10.13182/fst13-a16945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
47
|
Hishitani Y, Ogata A, Shima Y, Hirano T, Ebina K, Kunugiza Y, Shi K, Narazaki M, Hagihara K, Tomita T, Yoshikawa H, Tanaka T, Kumanogoh A. Retention of tocilizumab and anti-tumour necrosis factor drugs in the treatment of rheumatoid arthritis. Scand J Rheumatol 2013; 42:253-9. [PMID: 23470089 DOI: 10.3109/03009742.2012.762037] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVES The retention of the anti-rheumatic agent tocilizumab (TCZ) has not been well documented in patients with rheumatoid arthritis (RA). We conducted an observational study to compare the retention of TCZ and anti-tumour necrosis factor (TNF) drugs in the treatment of patients with RA. METHOD We reviewed continuation rates and causes of discontinuation of biological agents (biologics) by assessing medical records of patients with RA who were administered biologics at our institute from September 1999 to April 2012, using the Osaka University Biologics for Rheumatic Diseases (BiRD) registry. RESULTS A total of 401 patients were included. TCZ, infliximab (IFX), etanercept (ETN), and adalimumab (ADA) were administered to 97, 103, 143, and 58 patients, respectively. There were some differences between the baseline characteristics of the groups. The median duration (range) of TCZ, IFX, ETN, and ADA administration was 2.5 (0.1-12.6), 1.9 (0.0-7.7), 2.9 (0.0-11.3), and 1.3 (0.0-3.4) years, respectively. Continuation rates for TCZ and ETN were significantly higher than those for IFX and ADA. Multivariate analyses showed that discontinuation due to lack or loss of efficacy was significantly less common in the TCZ group than in the other groups. Discontinuation due to overall adverse events was not significantly different between treatment groups. CONCLUSION TCZ and ETN show better retention than IFX or ADA in the treatment of RA.
Collapse
|
48
|
Huang CC, Sugino K, Shima Y, Guo C, Bai S, Mensh BD, Nelson SB, Hantman AW. Convergence of pontine and proprioceptive streams onto multimodal cerebellar granule cells. eLife 2013; 2:e00400. [PMID: 23467508 PMCID: PMC3582988 DOI: 10.7554/elife.00400] [Citation(s) in RCA: 172] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Accepted: 01/28/2013] [Indexed: 12/30/2022] Open
Abstract
Cerebellar granule cells constitute the majority of neurons in the brain and are the primary conveyors of sensory and motor-related mossy fiber information to Purkinje cells. The functional capability of the cerebellum hinges on whether individual granule cells receive mossy fiber inputs from multiple precerebellar nuclei or are instead unimodal; this distinction is unresolved. Using cell-type-specific projection mapping with synaptic resolution, we observed the convergence of separate sensory (upper body proprioceptive) and basilar pontine pathways onto individual granule cells and mapped this convergence across cerebellar cortex. These findings inform the long-standing debate about the multimodality of mammalian granule cells and substantiate their associative capacity predicted in the Marr-Albus theory of cerebellar function. We also provide evidence that the convergent basilar pontine pathways carry corollary discharges from upper body motor cortical areas. Such merging of related corollary and sensory streams is a critical component of circuit models of predictive motor control. DOI:http://dx.doi.org/10.7554/eLife.00400.001 Learning a new motor skill, from riding a bicycle to eating with chopsticks, involves the cerebellum—a structure located at the base of the brain underneath the cerebral hemispheres. Although its name translates as ‘little brain' in Latin, the cerebellum contains more neurons than all other regions of the mammalian brain combined. Most cerebellar neurons are granule cells which, although numerous, are simple neurons with an average of only four excitatory inputs, from axons called mossy fibers. These inputs are diverse in nature, originating from virtually every sensory system and from command centers at multiple levels of the motor hierarchy. However, it is unclear whether individual granule cells receive inputs from only a single sensory source or can instead mix modalities. This distinction has important implications for the functional capabilities of the cerebellum. Now, Huang et al. have addressed this question by mapping, at extremely high resolution, the projections of two pathways onto individual granule cells—one carrying sensory feedback from the upper body (the proprioceptive stream), and another carrying motor-related information (the pontine stream). Using a combination of genetic and viral techniques to label the pathways, Huang and co-workers identified regions where the two types of fiber terminated in close proximity. They then showed that around 40% of proprioceptive granule cells formed junctions, or synapses, with two (or more) fibers carrying different types of input. These cells were not uniformly distributed throughout the cerebellum but tended to occur in ‘hotspots’. Lastly, Huang et al. examined the type of information conveyed by the sensory and motor-related input streams whenever they contacted a single granule cell. They confirmed that when the sensory input consisted of feedback from the upper body, the motor input consisted of copies of motor commands related to the same body region. Because it is thought that the cerebellum converts sensory information into representations of the body's movements, directing motor commands to these same circuits may allow the cerebellum to predict the consequences of a planned movement prior to, or without, the actual movement occurring. The work of Huang et al. provides evidence to support the previously controversial idea that granule cells in the mammalian cerebellum receive both sensory and motor-related inputs. The labeling technique that they used could also be deployed to study the inputs to the cerebellum in greater detail, which should yield new insights into the functioning of this part of the brain. DOI:http://dx.doi.org/10.7554/eLife.00400.002
Collapse
|
49
|
Nakajima J, Nakashima T, Shima Y, Fukuda H, Yamane T. A facile transphosphatidylation reaction using a culture supernatant of actinomycetes directly as a phospholipase D catalyst with a chelating agent. Biotechnol Bioeng 2012; 44:1193-8. [PMID: 18618545 DOI: 10.1002/bit.260441006] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
An attempt was made to use the phospholipase D (PLD)- containing culture supernatants of actinomycetes directly as catalysts for the transphosphatidylation reaction of phosphatidylcholine (PC) to phosphatidylethanolamine (PE) in a biphasic system. Of the five actinomycetes (three Streptomyces sp. and two Streptoverticillium sp.) examined, three (St. mediocidicus, Stv. cinnamoneum and Stv. hachijoense) exhibited good PLD production performance, but the selectivity (ratio of transphosphatidylation to hydrolysis) of the PLDs in the culture supernatant of all three actinomycetes were significantly low. However, the addition of EDTA to the reaction mixture as a chelating agent remarkably improved the selectivity of the PLDs, which approached 100% in all the culture supernatants. Commercially available PLDs were also investigated and classified into two types. The PLDs of one type had high selectivity and no metal was required for the enzyme activity, while those of the other type showed low selectivity and a metal was necessary for the enzyme to be activated. From this finding, it was considered that the culture supernatants used in this study contained several PLDs of both types. When the chelating agent was added to the reaction mixture, the hydrolysis due to PLDs with low selectivity was suppressed by removal of the essential metal, resulting in an increased in the overall selectivity of the PLDs in the culture supernatant. Repeated batch transphosphatidylation reactions were performed 20 times, reusing the PLDs in the aqueous phase by centrifugation; the reaction rate gradually decreased to 60% of that of batch 1 by batch 20. This suggests that the transphosphatidylation reaction using a culture supernatant has potential for industrial application. (c) 1994 John Wiley & Sons, Inc.
Collapse
|
50
|
Yasuhara R, Yoshikawa M, Morimoto M, Yamada I, Kawahata K, Funaba H, Shima Y, Kohagura J, Sakamoto M, Nakashima Y, Imai T, Minami T. Design of the polarization multi-pass Thomson scattering system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:10E326. [PMID: 23126984 PMCID: PMC3411556 DOI: 10.1063/1.4734495] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2012] [Accepted: 06/25/2012] [Indexed: 06/01/2023]
Abstract
A novel configuration of the multi-pass Thomson scattering (TS) system is proposed to improve the time resolution and accuracy of electron temperature measurements by use of a polarization control technique. This configuration can realize a perfect coaxial multi-passing at each pass, and the number of round trips is not limited by the optical configuration. To confirm the feasibility of the new method, we installed this system in the GAMMA 10 plasma system. As a result, the integrated scattering signal of the double-pass configuration is about two times larger than that of the single-pass configuration. These results are in good agreement with the design.
Collapse
|