26
|
Kadoya Y, Fuketa M, Atlam ES, Morita K, Sumitomo T, Aoe J. A compression algorithm using integrated record information for translation dictionaries. Inf Sci (N Y) 2004. [DOI: 10.1016/j.ins.2003.07.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
27
|
Nakagawa S, Kadoya Y, Kobayashi A, Tatsumi I, Nishida N, Yamano Y. Kinematics of the patella in deep flexion. Analysis with magnetic resonance imaging. J Bone Joint Surg Am 2003; 85:1238-42. [PMID: 12851348 DOI: 10.2106/00004623-200307000-00009] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Little information is available on the kinematics of the normal knee in deep flexion. The purpose of this study was to use magnetic resonance imaging to analyze the patellofemoral articulation in deep flexion. METHODS Axial scans were made of the patellofemoral joint of twenty healthy Japanese volunteers with the knee in approximately 90 degrees of flexion, in maximum active flexion (mean [and standard deviation], 140 degrees +/- 10 degrees ), and in maximum passive flexion (mean, 156 degrees +/- 5 degrees ). A fat-suppressed, three-dimensional, fast low-angle shot sequence was used to visualize the articular cartilage. The patellofemoral contact area was determined on sequential images and was reconstructed three-dimensionally. RESULTS At 90 degrees of flexion, the contact area on the patella was continuous over the medial and lateral facets in fourteen knees and was located in the proximal half of the articular surface. At maximum active and passive flexion, the odd facet engaged in fifteen and eighteen knees, respectively. At maximum passive flexion, the contact area of the lateral facet moved distally and decreased significantly (p = 0.0002). From 90 degrees of flexion to maximum active flexion, the mean total contact area remained constant (3.43 +/- 0.70 and 3.62 +/- 0.72 cm (2), respectively); it then decreased significantly in maximum passive flexion (2.96 +/- 0.78 cm (2), p = 0.04). CONCLUSIONS The contact area on the patella was divided into two parts (the odd and lateral facets) and moved distally in deep knee flexion. The size of the contact area on the lateral facet significantly decreased in maximum passive flexion.
Collapse
|
28
|
Uehara K, Kadoya Y, Kobayashi A, Ohashi H, Yamano Y. Anthropometry of the proximal tibia to design a total knee prosthesis for the Japanese population. J Arthroplasty 2002; 17:1028-32. [PMID: 12478514 DOI: 10.1054/arth.2002.35790] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Anthropometric data on proximal tibiae of 100 knees in 80 Japanese patients undergoing total knee arthroplasty were obtained. Anterior-posterior (AP) and medial-lateral (ML) lengths of the tibia were measured on computed tomography scans and intraoperatively on tibial resection surfaces. A special small component is unnecessary, and size variation should focus on ML length of 65 to 75 mm because this includes 90% of women's knees. AP-to-ML ratio had a negative correlation with ML length, indicating that small knees were longer in the AP direction. Most prostheses had AP mismatch up to 5 mm for small women's knees. These data could provide the basis for designing the optimal tibial component for most of the Asian-Pacific population.
Collapse
|
29
|
Uehara K, Kadoya Y, Kobayashi A, Ohashi H, Yamano Y. Bone anatomy and rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 2002:196-201. [PMID: 12218484 DOI: 10.1097/00003086-200209000-00018] [Citation(s) in RCA: 119] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The purpose of the current study was to investigate the bone anatomy in determining the rotational alignment in total knee arthroplasty using computed tomography. Axial images of 109 knees in 83 patients with varus osteoarthritis who had total knee arthroplasty were analyzed. On the images of the distal femur and the proximal tibia, a baseline for the anteroposterior axis of each component was drawn based on the epicondylar axis for the femur and the medial (1/3) of the tibial tuberosity for the tibia. The angle between these two lines was analyzed as the rotational mismatch between the components when they were aligned to the anatomic landmarks of each bone. Fifty-four knees (49.5%) had an angle of 5 degrees or greater and 13 knees (11.9%) had an angle of 10 degrees or greater. There was a tendency to align the tibial component in external rotation relative to the femoral component. The results indicated that the landmarks of each bone were the intrinsic cause of the rotational mismatch in knees with varus osteoarthritis. Surgeons doing total knee arthroplasties should be aware of this and check the rotational mismatch between the components. When it is present, the tibial component should be realigned to match the femoral component rotation to minimize problems caused by the mismatch.
Collapse
|
30
|
Katayama K, Dobashi Y, Kitagawa M, Kamekura S, Kawai M, Kadoya Y, Kameya T. Overexpression of cdk4/cyclin D1 induces apoptosis in PC12 cells in the presence of trophic support. FEBS Lett 2001; 509:382-8. [PMID: 11749960 DOI: 10.1016/s0014-5793(01)03200-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The induction of apoptosis by cell cycle regulator molecules under conditions optimal for exponential growth was examined in rat pheochromocytoma PC12 cells by overexpression of cyclins and cyclin-dependent kinases (cdks). By flow cytometry and by immunofluorescence, only cells overexpressing cdk4 or cyclin D1 underwent apoptosis, which was not associated with G1-arrest. Cdk4 kinase activity was significantly higher in cdk4-, or cyclin D1-expressing cells. Furthermore, induction of apoptosis by cdk4 was abrogated by co-transfection of p16(INK4), or dominant negative cdk4. These results suggest that upregulation of cdk4 kinase activity is a primary and critical mediator of apoptosis in PC12 cells under physiological conditions.
Collapse
|
31
|
Kadoya Y. [Laminin domains involved in the epithelial organogenesis]. SEIKAGAKU. THE JOURNAL OF JAPANESE BIOCHEMICAL SOCIETY 2001; 73:1221-6. [PMID: 11725538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
32
|
Kadoya Y, Kobayashi A, Komatsu T, Nakagawa S, Yamano Y. Effects of posterior cruciate ligament resection on the tibiofemoral joint gap. Clin Orthop Relat Res 2001:210-7. [PMID: 11603671 DOI: 10.1097/00003086-200110000-00023] [Citation(s) in RCA: 115] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The effect of posterior cruciate ligament resection on the tibiofemoral joint gap was analyzed in 30 patients with varus osteoarthritis of thee knee who underwent total knee replacement. The medial soft tissue was released and the bone cut was made without preserving the bone segment of the tibia to which the posterior cruciate ligament was attached. Then the medial and lateral joint gaps in full extension and 90 degrees flexion were measured before and after the posterior cruciate ligament was resected using a tensioning device. After the resection, the flexion gap significantly increased in the medial and the lateral sides (4.8 +/- 0.4 and 4.5 +/- 0.4 mm, respectively, mean +/- standard error) compared with those seen in the extension gap (0.9 +/- 0.2 and 0.8 +/- 0.2 mm). There was no significant difference between the changes in the medial and lateral gaps. The mean value of the flexion gap was 2 mm smaller than the extension gap before the resection and 1.7 mm larger after the sacrifice. Overall, posterior cruciate ligament resection resulted in an increase in the flexion gap and made space for approximately 3-mm thicker polyethylene. The flexion gap can be controlled selectively with posterior cruciate ligament release.
Collapse
|
33
|
Oonishi H, Kadoya Y, Iwaki H, Kin N. Total hip arthroplasty with a modified cementing technique using hydroxyapatite granules. J Arthroplasty 2001; 16:784-9. [PMID: 11547378 DOI: 10.1054/arth.2001.23724] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Results of total hip arthroplasties with a modified cementing technique using hydroxyapatite were evaluated. Femoral and acetabular components were inserted with cement after hydroxyapatite granules (phi = 100-300 microm). The study group comprised 268 hips in 232 patients. The diagnosis was osteoarthritis in 197 patients. After a mean follow-up of 10.3 years, 5 patients died and 30 patients were lost to follow-up, leaving 218 hips (197 patients; mean age, 58.2 years) for evaluation. Three hips were revised because aseptic (1) and septic (2) loosening of acetabular components. Six other sockets were defined as radiologically loose, and no femoral component was loose. Osteolysis was identified in 2 femora and 0 acetabula. The overall loosening rate was 3.2% for acetabular components and 0% for femoral components. These results show that the loosening rate of cemented total hip arthroplasty components, especially the acetabulum, is reduced markedly with this modified cementing technique.
Collapse
|
34
|
Kitano T, Ateshian GA, Mow VC, Kadoya Y, Yamano Y. Constituents and pH changes in protein rich hyaluronan solution affect the biotribological properties of artificial articular joints. J Biomech 2001; 34:1031-7. [PMID: 11448695 DOI: 10.1016/s0021-9290(01)00058-6] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The relationship between the coefficient of friction and pH value or protein constituents of lubricating fluid, together with viscosity, were studied within a bearing surface model for artificial joint, ultra-high molecular weight polyethylene (UHMWPE) against stainless steel (SUS), using a mechanical spectrometer. Four lubricants were tested in this study: sodium hyaluronate (HA), HA with albumin, HA with gamma-globulin, and HA with (L)alpha-dipalmitoyl phosphatidylcholine ((L)alpha-DPPC). The coefficient of friction between UHMWPE and SUS in HA with albumin or HA with gamma-globulin varied from 0.035 to 0.070 depending on angular velocity and pH. The coefficient of friction in HA or HA with (L)alpha-DPPC varied from 0.023 to 0.045 depending on angular velocity and pH. The variation in pH for HA with albumin had a large effect on the coefficient of friction at low range of angular velocity with viscosity independence. The variation in pH for HA with gamma-globulin had a large effect on the coefficient of friction with viscosity dependence at high angular velocity. The addition of (L)alpha-DPPC showed a small effect on the coefficient of friction at low angular velocity. This study confirms that the presence of albumin in the lubricant promotes pH dependence and viscosity independence of the tribological properties at low speed while the presence of globulin promotes pH and viscosity independence at low speed and promotes pH and viscosity dependence at high speed in the lubrication of UHMWPE against SUS. This study supports the clinical hypothesis that the effect of constituents and pH changes in periprosthetic fluid for the lubrication is a clue toward resolving many complications after total joint replacement.
Collapse
|
35
|
Oonishi H, Kadoya Y, Masuda S. Gamma-irradiated cross-linked polyethylene in total hip replacements--analysis of retrieved sockets after long-term implantation. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2001; 58:167-71. [PMID: 11241335 DOI: 10.1002/1097-4636(2001)58:2<167::aid-jbm1003>3.0.co;2-a] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The purpose of this study was to evaluate the mechanical and chemical characteristics of gamma-irradiated, cross-linked polyethylene after long-term service in vivo. Two gamma-irradiated ultra high molecular weight polyethylene (RCH 1000, molecular weight: 10(6)) total hip replacement sockets were retrieved at 15 and 16 years after implantation. Mechanical and chemical characteristics of the sockets were evaluated in comparison with nonirradiated sockets. Significant surface oxidation occurred in the nonirradiated sockets; up to 75% of that seen in the irradiated ones. The mechanical properties of the irradiated sockets were not subject to increased deterioration in the presence of high free radical content. The cross-link was stable and was retained for a long period both in vivo and in ambient air. These data indicate that gamma-irradiated polyethylene was not subject to increased oxidative degradation during long-term service in vivo and confirmed the usefulness of this material as an articulating surface in total hip replacement.
Collapse
|
36
|
Nakagawa S, Kadoya Y, Todo S, Kobayashi A, Sakamoto H, Freeman MA, Yamano Y. Tibiofemoral movement 3: full flexion in the living knee studied by MRI. THE JOURNAL OF BONE AND JOINT SURGERY. BRITISH VOLUME 2000; 82:1199-200. [PMID: 11132287 DOI: 10.1302/0301-620x.82b8.10718] [Citation(s) in RCA: 157] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We studied active flexion from 90 degrees to 133 degrees and passive flexion to 162 degrees using MRI in 20 unloaded knees in Japanese subjects. Flexion over this arc is accompanied by backward movement of the medial femoral condyle of 4.0 mm and by backward movement laterally of 15 mm, i.e., by internal rotation of the tibia. At 162 degrees the lateral femoral condyle lies posterior to the tibia.
Collapse
|
37
|
Nakagawa S, Kadoya Y, Todo S, Kobayashi A, Sakamoto H, Freeman MAR, Yamano Y. Tibiofemoral movement 3: full flexion in the living knee studied by MRI. ACTA ACUST UNITED AC 2000. [DOI: 10.1302/0301-620x.82b8.0821199] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We studied active flexion from 90° to 133° and passive flexion to 162° using MRI in 20 unloaded knees in Japanese subjects. Flexion over this arc is accompanied by backward movement of the medial femoral condyle of 4.0 mm and by backward movement laterally of 15 mm, i.e., by internal rotation of the tibia. At 162° the lateral femoral condyle lies posterior to the tibia.
Collapse
|
38
|
Abstract
Between 1971 and 1978, 62 patients underwent total hip replacements (THRs) with high-dose (100 Mrad) gamma-irradiated polyethylene sockets. After a mean follow-up of 17. 3 years (range, 6-23 years), 28 hips in 26 patients were available for radiographic wear measurement. Twenty-three THRs with non-irradiated sockets were used as controls, although all these hips had loosened within 13 years. The rate of linear wear in irradiated sockets was significantly lower throughout the follow-up period (less than 2 years, 0.16 and 0. 38 mm/year; 2-6 years, 0.05 and 0.29 mm/year; more than 6 years, 0. 05 and 0.28 mm/year, respectively; mean, P < 0.0001). This result has demonstrated that high-dose gamma-irradiated, cross-linked polyethylene is a promising articulating material for THRs.
Collapse
|
39
|
Oonishi H, Kadoya Y, Iwaki H, Kin N. Hydroxyapatite granules interposed at bone-cement interface in total hip replacements: histological study of retrieved specimens. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2000; 53:174-80. [PMID: 10713564 DOI: 10.1002/(sici)1097-4636(2000)53:2<174::aid-jbm7>3.0.co;2-o] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The effect of hydroxyapatite (HA) granules interposed between bone and polymethylmethacrylate (PMMA) bone cement in total hip replacement was histologically evaluated. The technique consisted of smearing 2-5 g of HA granules (straight phi = 100-300 microm) onto the bone surface just before cementing. Four specimens containing well-fixed bone-cement interface were retrieved at 1, 2, 6, and 10 years postoperatively and examined with back-scattered electron microscopy and light microscopy. The majority of HA granules were incorporated into remodeled trabeculae, and highly convoluted bone-cement interface was maintained up to 10 years. The presence of active remodeling in the adjacent bone was observed. There were no significant inflammatory or foreign body reactions against interposed HA granules. In one specimen retrieved from a patient with rheumatoid arthritis, bone formation around HA granules was limited after 1 year. These results have provided histological evidence for the significantly reduced incidence of radiolucent lines in total hip replacement with this cementing technique, reported elsewhere.
Collapse
|
40
|
Yano H, Ohashi H, Kadoya Y, Kobayashi A, Yamano Y, Tanabe Y. Histologic and mechanical evaluation of impacted morcellized cancellous allografts in rabbits: comparison with hydroxyapatite granules. J Arthroplasty 2000; 15:635-43. [PMID: 10960003 DOI: 10.1054/arth.2000.6625] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
The bioactivity and mechanical properties of morcellized allografts and hydroxyapatite (HA) granules were evaluated in a rabbit model. Allografts were replaced by viable trabecular structures within 8 weeks. The yield strength and stiffness of allografts were within normal cancellous bone levels by 3 weeks and were maintained afterward. The amount of newly formed bone around HA granules was comparable to that around allografts. The yield strength and stiffness of HA granules were significantly higher than those of allografts at 3 and 12 weeks. Allografts offer the advantage of being replaced by host-bone without significant deterioration in mechanical properties over the course of remodeling. HA granules can also be used for a bone substitute given their bioactivity in bone conduction and superiority in mechanical properties to allografts.
Collapse
|
41
|
Ohashi H, Kobayashi A, Kadoya Y, Yamano Y, Oonishi H, Iwaki H. Effect of particles and interface conditions on fibrous tissue interposition between bone and implant. A particle challenge model in rabbit. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2000; 11:255-259. [PMID: 15348040 DOI: 10.1023/a:1008936830622] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Interposed fibrous tissue at bone-implant interfaces was quantitatively measured in the presence or absence of polyethylene (PE) or alumina particles. Three different conditions of the interface were designed by implanting a pre-polymerized polymethylmethacrylate (PMMA) plug (plug group), a doughy PMMA (injection group) and a hydroxyapatite (HA) plug (HA group) in the hole drilled at the intercondylar notch of rabbit knees. PE (170+/-18 microm) or alumina particles (88+/-26 microm) were repeatedly administered into the knee joints at one month intervals (six times). All animals were sacrificed seven months after the implantation. The bone-implant interface was histomorphometrically examined using undecalcified ground sections. In the plug group, the PE particles significantly increased the extent of the interposed fibrous tissue (p < 0.05), while the alumina particles showed no effect. In contrast, both particles showed no significant effects in the injection and the HA groups. These results indicate that both particle characteristics and conditions of the bone-implant interface affected particle-induced fibrous tissue interposition. The loose PMMA plug with PE particles induced the greatest amount of fibrous tissue interposition.
Collapse
|
42
|
Kadoya Y, Yamashina S. Localization of laminin-5, HD1/plectin, and BP230 in the submandibular glands of developing and adult mice. Histochem Cell Biol 1999; 112:417-25. [PMID: 10651091 DOI: 10.1007/s004180050423] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
We studied the distributions of laminin-5 and hemidesmosome components, HD1/plectin and BP230, in the submandibular glands of adult and developing mice. In adult mice, laminin-5 was expressed in the basement membranes of both the myoepithelial cells and excretory ducts. The former expression was predictable because laminin-5 is a ligand for hemidesmosomes, which appear in myoepithelial cells and stratified epithelium. However, the latter expression pattern suggested that the non-stratified epithelium of the excretory duct might also be associated with hemidesmosomes. During fetal development, laminin-5 was found in the basement membrane of developing ducts but not epithelial end buds in which future lobules are formed by epithelial branching. The expression of HD1/plectin but not BP230 was noted in the developing duct at early embryonic stages, indicating the presence of type II hemidesmosomes. Expression of BP230 appeared in the excretory duct epithelium at around the day of birth. At this stage, the typical hemidesmosome was observed in the duct epithelium. Our results suggest that laminin-5 is involved in duct development rather than epithelial branching. The results also suggest that the developing duct epithelium interacts with laminin-5 through the type II hemidesmosome, which later matures into a typical hemidesmosome upon the onset of expression of BP230.
Collapse
|
43
|
Tanabe Y, Wakui T, Kobayashi A, Ohashi H, Kadoya Y, Yamano Y. Determination of mechanical properties of impacted human morsellized cancellous allografts for revision joint arthroplasty. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 1999; 10:755-760. [PMID: 15347946 DOI: 10.1023/a:1008995630200] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This paper deals with the characterization of mechanical properties of impacted morsellized cancellous allograft (IMCA) produced by dynamic compaction of allograft femoral heads ground by commercially available bone mills, i.e. rotating rasp and reciprocating type bone mills. Various ranges and profiles of particle size in the graft aggregates were obtained using these bone mills, and the effect of number of compaction as well as the distribution of particle sizes on the mechanical properties of IMCA under quasistatic compression and shear loading conditions was discussed. The morsellized cancellous allograft prepared by the reciprocating type bone mill showed a broad distribution of particle sizes, and gave IMCA superior mechanical properties to the graft with a more uniform size distribution, or prepared by the rotating rasp type bone mills. The increase of number of compaction also improved the mechanical properties of IMCA in compression.
Collapse
|
44
|
Todo S, Kadoya Y, Moilanen T, Kobayashi A, Yamano Y, Iwaki H, Freeman MA. Anteroposterior and rotational movement of femur during knee flexion. Clin Orthop Relat Res 1999:162-70. [PMID: 10335295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
This study was designed to analyze anteroposterior and rotational movement of femoral condyles during knee flexion from 15 degrees to 90 degrees using magnetic resonance imaging. After a pilot study, scans were made in 10 healthy male Japanese volunteers. When centers of the circular profiles of posterior femoral condyles were used as reference points, the medial and lateral femoral condyles displaced posteriorly 1.9 +/- 0.8 mm and 2.3 +/- 0.5 mm, respectively (mean +/- standard error). Duplicate examinations on two separate occasions revealed the accuracy of this procedure was in the range of 1 to 2 mm. These results have confirmed that femoral rollback occurs in the unloaded normal knee during flexion from 15 degrees to 90 degrees, but its magnitude is small (2 mm). The results obtained in this in vivo measurement of anteroposterior movement of the femoral condyles have relevance for total knee replacement design.
Collapse
|
45
|
Hosokawa Y, Takahashi Y, Kadoya Y, Yamashina S, Nomizu M, Yamada Y, Nogawa H. Significant role of laminin-1 in branching morphogenesis of mouse salivary epithelium cultured in basement membrane matrix. Dev Growth Differ 1999; 41:207-16. [PMID: 10223717 DOI: 10.1046/j.1440-169x.1999.00419.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Mouse submandibular epithelium shows branching morphogenesis in mesenchyme-free conditions when covered with a basement membrane matrix (Matrigel) in medium supplemented with epidermal growth factor. In the present study, the role of laminin-1 (LN1), a major glycoprotein of Matrigel, in this culture system was defined. When the epithelium was cultured in a LN1-nidogen gel, the epithelium showed much branching, comparable to that observed with Matrigel. By electron microscopy, only a felt-like matrix was formed on the epithelial surface in the LN1-nidogen gel cultures, while an organized basal lamina structure was formed on the epithelial surface in direct or transfilter recombination cultures with mesenchyme. Next, the epithelium covered with Matrigel was cultured in medium containing either biologically active peptides from LN1, IKVAV-including peptide (2097-2108), AG10 (2183-2194), AG32 (2370-2381) or AG73 (2719-2730) from the alpha1 chain, or YIGSR-including peptide (926-933) from the beta1 chain. Only AG73 (RKRLQVQLSIRT from the alpha1 chain carboxyl-terminal globular domain) inhibited the epithelial branching in Matrigel. These results suggest that LN1-nidogen can support the branching morphogenesis of submandibular epithelium even if LN1-nidogen is not assembled into an intact basal lamina, and that the AG73 sequence is an important site on LN1, which interacts with submandibular epithelial cells.
Collapse
|
46
|
Sumitomo H, Kadoya Y, Yamanishi M. Wideband deep penetration of photon-number fluctuations into the quantum regime in series-coupled light-emitting diodes. OPTICS LETTERS 1999; 24:40-42. [PMID: 18071401 DOI: 10.1364/ol.24.000040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Experimental results on the squeezing of photon-number fluctuations of series-coupled LED's driven by a constant-voltage source are presented that illustrate the advantage of series-coupled LED's, namely, a greater squeezing capability than that of a single LED driven through an equivalent series resistor. We discuss the microscopic origin of the deep squeezing on the basis of quantum-mechanical Langevin equations.
Collapse
|
47
|
Kitano T, Ohashi H, Kadoya Y, Kobayashi A, Yutani Y, Yamano Y. Measurements of zeta potentials of particulate biomaterials in protein-rich hyaluronan solution with changes in pH and protein constituents. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 1998; 42:453-7. [PMID: 9788509 DOI: 10.1002/(sici)1097-4636(19981205)42:3<453::aid-jbm15>3.0.co;2-h] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This study was undertaken to determine the zeta potentials of particulate biomaterials in three types of protein-rich hyaluronan solution with changes in pH; a microelectrophoretic method was used. For the purpose of determining the pH value of synovial fluid in various inflammatory conditions, we collected synovial fluid samples from joints with osteoarthritis (OA), rheumatoid arthritis (RA), and those undergoing revisions arthroplasties. The mean values of the pH in the synovial fluid from joints with OA, RA, and revision arthroplasty were shown to be 7.9, 7.5, and 8.1, respectively. The pH-zeta potential curves obtained differed, depending on the biomaterial and the medium. Addition of gamma-globulin to the medium reduced the absolute value of the zeta potentials of some of the biomaterials. The findings of this study suggest that the electrophoretic behaviors of the particulate biomaterials tested in this study are affected by the protein constituents of and pH changes in protein-rich synovial fluid. The values we obtained will be useful as reference standards and will also aid in the study of the surface phenomena of biomaterials.
Collapse
|
48
|
Gresik EW, Kashimata M, Kadoya Y, Yamashina S. The EGF system in fetal development. EUROPEAN JOURNAL OF MORPHOLOGY 1998; 36 Suppl:92-7. [PMID: 9825900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
Immunohistochemical localization of the epidermal growth factor receptor (EGFR) disclosed a wide distribution of this protein in diverse fetal tissues. This review focuses on some of the vast work on the expression and operation of the EGFR and its principal ligands in fetal organogenesis.
Collapse
|
49
|
Kadoya Y, Nomizu M, Sorokin LM, Yamashina S, Yamada Y. Laminin alpha1 chain G domain peptide, RKRLQVQLSIRT, inhibits epithelial branching morphogenesis of cultured embryonic mouse submandibular gland. Dev Dyn 1998; 212:394-402. [PMID: 9671943 DOI: 10.1002/(sici)1097-0177(199807)212:3<394::aid-aja7>3.0.co;2-c] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Active sequences from the laminin alpha1 and alpha2 chain carboxyl-terminal globular domains (G domain) have been identified by screening overlapping synthetic peptides in a number of biological assays (Nomizu et al. [1995] J. Biol. Chem. 270:20583-20590; Nomizu et al. [1996] FEBS Lett. 396:37-42). We have tested the activity of these peptides in submandibular gland explants of embryonic day 13 mice to determine the functional sites involved in organ development. The laminin alpha1 chain peptide, RKRLQVQLSIRT (residues 2719-2730 and designated AG-73), significantly inhibited epithelial branching morphogenesis. In contrast, other cell adhesive laminin alpha1 chain peptides including the AASIKVAVSADR and NRWHSIYITRFG failed to inhibit the branching. MG-73, a homologue of AG-73 from the laminin alpha2 chain, did not inhibit the branching. The alpha2 chain peptide had no effect, which may be due to the low levels of this laminin chain in day 13 mice. Laminin alpha2 chain-specific monoclonal antibodies strongly reacted with the basement membranes of developed acini but only weakly stained embryonic day 13 submandibular epithelium. The expression of E-cadherin and alpha6 integrin, as detected by immunofluorescence, were unchanged in both AG-73 and control scramble peptide-treated epithelial cells of the explants. In contrast, immunostaining of nidogen/entactin showed that explants treated with AG-73 for 3 days had a discontinuous basement membrane. Explants treated for 3 days with control peptide showed a normal basement membrane. These results suggest that the region containing the AG-73 sequence of the laminin alpha1 chain is crucial for development of submandibular gland at early embryonic stages. The discontinuous basement membrane in AG-73-treated explants may indicate an important role for this region in basement membrane assembly.
Collapse
|
50
|
Kadoya Y, Kobayashi A, Ohashi H. Wear and osteolysis in total joint replacements. ACTA ORTHOPAEDICA SCANDINAVICA. SUPPLEMENTUM 1998; 278:1-16. [PMID: 9524528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
UNLABELLED This presentation summarizes the results of our recent studies on the pathogenesis of osteolysis around total joint arthroplasties. First, interface tissues with adjacent bone were retrieved and histopathologically investigated with reference to the cells on the bone surface. Secondly, polyethylene particles were extracted with the tissue digestion method and characterized with scanning electron microscopy. Finally, an animal model for osteolysis was created and various interface conditions were compared concerning their resistance to particle migration. Histopathological examinations demonstrated that active bone formation, regarded as a repair process, was the commonest feature, even in revised cases. They also highlighted the role played by macrophages, not as cells producing inflammatory mediators which could activate osteoclasts, but as cells primarily responsible for the bone loss in osteolytic lesions. Among the particle species present, only polyethylene particles were shown to play a significant role in macrophage recruitment and subsequent osteolysis. A quantitative extraction of polyethylene particles showed a significant difference in the "number" of particles between osteolysis positive and negative cases whereas the "sizes" of particles were similar in these two groups. The critical number of particles for osteolysis was around 1 x 10(10) particles/g tissue and the cellular reaction against phagocytosable particles accumulated over this concentration may be the prerequisite for progression of osteolysis. The animal model for osteolysis indicated that the progression of osteolysis depends on the integrity of the bone-implant interface. We suggest that the solid fixation of the prosthesis performed by current techniques (e.g., improved cementing technique, hydroxyapatite coating) is beneficial for preventing particle migration and subsequent osteolysis. CLINICAL RELEVANCE Osteolysis induced by particulate wear debris from implant materials has been recognized as the major cause of long-term failure in total joint replacements. However, the development of preventive measures for this phenomenon has not been successful because the mechanism in which wear particles cause osteolysis is not quite clear. On the basis of results obtained in this study, we believe that the basic strategy for addressing the problem of osteolysis is to reduce the "number" of accumulated wear particles in the interface tissues. This could be achieved either by improving the materials or the geometry of the articulating counterface. Another possibility is to increase the integrity of the bone-implant interface to prevent particle migration. It is important to note that pre-clinical testing of materials and prosthetic designs should include an analysis of the characteristics of the particle generated (e.g., size and number). The widespread bone formation, even in revised cases, is encouraging in view of "conservative treatment" of aseptic loosening. Assuming that bone loss in aseptic loosening is not a remorseless process, some form of intervention, whether mechanical or pharmacological, might be possible to tip the balance more in favour of bone formation than resorption. A comprehensive understanding of the bone reactions in osteolysis, including the basic mechanisms of bone loss, shown in this study, are decisive for the development of preventive measures that may minimize the clinical impact of this phenomenon.
Collapse
|