26
|
Guo ZY, Sun WY, Michele Y, Zhang JL, Hu D, Su HN, Yang WM, Mao W. [Loss of BRCA associated protein 1 expression in malignant mesothelioma and its diagnostic application]. ZHONGHUA BING LI XUE ZA ZHI = CHINESE JOURNAL OF PATHOLOGY 2017; 46:699-703. [PMID: 29050072 DOI: 10.3760/cma.j.issn.0529-5807.2017.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the expression of BRCA-associated protein 1 (BAP1) in malignant mesothelioma, non-small cell lung cancer and carcinosarcoma, and its application in the differential diagnosis. Methods: Twenty-two cases of malignant mesothelioma including 17 epithelioid type, 2 sarcomatoid type and 3 biphasic type were collected.As the study control, 80 non-small cell lung cancers infringement pleural membrane(including 40 lung adenocarcinomas and 40 lung squamous cell carcinomas) and 15 carcinosarcomas were included. BAP1 expression was detected using immunohistochemical method. A differential diagnosis antibody panel, including calretinin, WT1, CK5/6, D2-40, CAM5.2, CEA, TTF1, Napsin A, p63 and p40 was tested in all cases. Results: All 80 cases of non-small cell lung cancer and 15 cases of carcinosarcoma were BAP1 positive. In contrast, 64% (14/22) of malignant mesotheliomas lost BAP1 expression (P<0.01). Addition of BAP1 to the mesothelioma marker panel, the diagnostic accuracy of malignant mesothelioma was enhanced to 93%. Focal expression of BAP1 in tumors suggested multiclonal evolution of mesothelioma. Conclusions: Loss of BAP1 expression helps to confirm the diagnosis of malignant mesothelioma whereas all non-small cell lung cancer expresses BAP1. It is therefore recommended that BAP1 can be used in conjunction with other immunohistochemical markers to improve the diagnostic accuracy of malignant mesothelioma.
Collapse
|
27
|
He XS, Guo ZY. [The era of ischemia-free organ transplantation is coming]. ZHONGHUA YI XUE ZA ZHI 2017; 97:2810-2811. [PMID: 29050141 DOI: 10.3760/cma.j.issn.0376-2491.2017.36.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
|
28
|
Guo ZY, Zhang JX, Wu M, Mei YF, Lin XJ, Bu C, Xie Y, Wang J. Meta-analysis of the association between PADI4 -92C/G polymorphism and rheumatoid arthritis in the Chinese population. Braz J Med Biol Res 2017; 50:e6115. [PMID: 28832760 PMCID: PMC5561805 DOI: 10.1590/1414-431x20176115] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2016] [Accepted: 06/14/2017] [Indexed: 11/22/2022] Open
Abstract
Many studies have evaluated the correlation between peptidylarginine deiminase 4 (PADI4) -92C/G polymorphism and rheumatoid arthritis (RA), but the results remain inconclusive. Therefore, we performed a meta-analysis in the Chinese population to provide comprehensive data on the association between PADI4 -92C/G polymorphism and RA. Eligible studies published before May 2016 were identified in PubMed and Chinese databases. The strengths of these associations were assessed by pooled odds ratios (OR) and 95% confidence interval (CI). Eight studies documenting a total of 1351 RA cases and 1585 controls were included in this meta-analysis. In the overall analysis, a significant association between the PADI4 -92C/G polymorphism and RA was found in the Chinese population (G vs C: OR=1.32, 95%CI=1.02-1.71; GG+CG vs CC: OR=1.75, 95%CI=1.20-2.53). The subgroup analyses stratified by geographic area(s) and source of controls revealed significant results in South China, in hospital-based studies and population-based studies. In summary, this meta-analysis suggested that PADI4 -92C/G polymorphism may be associated with the RA incidence in the Chinese population, especially for South China. Further studies conducted on other ethnic groups are required for definite conclusions.
Collapse
|
29
|
Liu H, Tang H, Xiao W, Guo Z, Tian L, Gao Y. Sequential Bag-of-Words model for human action classification. CAAI TRANSACTIONS ON INTELLIGENCE TECHNOLOGY 2016. [DOI: 10.1016/j.trit.2016.10.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
30
|
Xu Y, Lv LN, Guo ZY, Zhang W. Invasion and metastasis ability of renal cancer cell strains 786-0: under the influence of miR-141. J BIOL REG HOMEOS AG 2016; 30:365-372. [PMID: 27358122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This study aimed to explore the invasion and metastasis ability of miR-141 in 786-0 renal cancer tissue cells, as well as identify the key function of endogenous miR-141 in adjustment and control of malignant activities of renal cancer. The renal cancer cell strain with overexpression of miR-141 and its control renal cancer cell line were constructed; methyl thiazolyl tetrazolium (MTT) assay was adopted to measure proliferation of renal cancer cells; Transwell assay was performed to measure the invasion and metastasis ability of cells; MTT assay and fluorescence activated cell sorting (FACS) were used for measurement of cell apoptosis and drug susceptibility. Results indicated that the expression of miR-141 in 786-0 cells could be significantly increased 400-fold by slow viruses that contained miR-141; moreover, c omprehensive functions showed that miR-141 inhibited the invasion and metastasis ability of renal cancer cells to a great extent (p less than 0.001), partially inhibited cell growth (p less than 0.05) and also induced cell cycle to be arrested in G0/G1 as well as reducing the number of cells in S phase (DNA replicative phase). Moreover, miR-141 could not induce morphologic changes of renal cancer cells, had no direct stimulating effect on cell apoptosis and could not improve the drug susceptibility of renal cancer cells to drugs such as cis-Dichlorodiamineplatinum (DDP), 5-fluorouracil (5-FU) and tumor-related apoptosis-inducing ligand (TRAIL). In conclusion, miR-141 can be considered an important cancer suppressor gene of renal cancer by inhibiting proliferation and metastasis of renal cancer cells.
Collapse
|
31
|
Peng SX, Zhang AL, Ren HT, Zhang T, Zhang JF, Xu Y, Guo ZY, Chen JE. Improvements of PKU PMECRIS for continuous hundred hours CW proton beam operation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02A706. [PMID: 26931924 DOI: 10.1063/1.4932399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In order to improve the source stability, a long term continuous wave (CW) proton beam experiment has been carried out with Peking University compact permanent magnet 2.45 GHz ECR ion source (PKU PMECRIS). Before such an experiment a lot of improvements and modifications were completed on the source body, the Faraday cup and the PKU ion source test bench. At the beginning of 2015, a continuous operation of PKU PMECRIS for 306 h with more than 50 mA CW beam was carried out after success of many short term tests. No plasma generator failure or high voltage breakdown was observed during that running period and the proton source reliability is near 100%. Total beam availability, which is defined as 35-keV beam-on time divided by elapsed time, was higher than 99% [S. X. Peng et al., Chin. Phys. B 24(7), 075203 (2015)]. A re-inspection was performed after another additional 100 h operation (counting time) and no obvious sign of component failure was observed. Counting the previous source testing time together, this PMECRs longevity is now demonstrated to be greater than 460 h. This paper is mainly concentrated on the improvements for this long term experiment.
Collapse
|
32
|
Peng SX, Zhang T, Ren HT, Zhang AL, Xu Y, Zhang JF, Guo ZY, Chen JE. Duty factor variation possibility from 1% to 100% with PKU microwave driven Cs-free volume H⁻ sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B125. [PMID: 26932007 DOI: 10.1063/1.4934816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Microwave driven cesium-free volume H(-) sources, that have the ability to deliver tens of mA H(-) at 35 keV both in CW and 10% duty factor (100 Hz/1 ms), were developed at Peking University (PKU) [S. X. Peng et al., in Proceeding of IPAC 2015, WEPWA027, Richmond, Virginia, USA, 3-8 May 2015]. Recently, special efforts were paid on the investigation of duty factor variation possibility from 1% to 100% with them. Most of the experiments were carried out with a pulsed length (τ) of 1 ms and different intervals of 99 ms, 49 ms, 39 ms, 29 ms, 19 ms, 9 ms, 4 ms, 2 ms, 1 ms, 0.5 ms, and 0 ms, respectively. Other experiments were focused on CW operation and fixed duty factor of 1%. Experimental results prove that PKU H(-) sources can deliver tens of mA H(-) at duty factor from 1% to 100%. The RF power efficiency increases steadily with the increasing of duty factor from 1% to CW at a fixed pulsed length. Under a given duty factor and pulsed length, RF power efficiency keeps constant and the H(-) current increases with RF power linearly. Details will be presented in the paper.
Collapse
|
33
|
Zhang AL, Peng SX, Ren HT, Zhang T, Zhang JF, Xu Y, Guo ZY, Chen JE. Study on space charge compensation in negative hydrogen ion beam. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B915. [PMID: 26932087 DOI: 10.1063/1.4932557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Negative hydrogen ion beam can be compensated by the trapping of ions into the beam potential. When the beam propagates through a neutral gas, these ions arise due to gas ionization by the beam ions. However, the high neutral gas pressure may cause serious negative hydrogen ion beam loss, while low neutral gas pressure may lead to ion-ion instability and decompensation. To better understand the space charge compensation processes within a negative hydrogen beam, experimental study and numerical simulation were carried out at Peking University (PKU). The simulation code for negative hydrogen ion beam is improved from a 2D particle-in-cell-Monte Carlo collision code which has been successfully applied to H(+) beam compensated with Ar gas. Impacts among ions, electrons, and neutral gases in negative hydrogen beam compensation processes are carefully treated. The results of the beam simulations were compared with current and emittance measurements of an H(-) beam from a 2.45 GHz microwave driven H(-) ion source in PKU. Compensation gas was injected directly into the beam transport region to modify the space charge compensation degree. The experimental results were in good agreement with the simulation results.
Collapse
|
34
|
Guo ZY, Yao GD, Fu LP, Fu ZG, Hou B. Effect of recombinant human endostatin on the expression of c-Myc and bFGF in mouse gastric cancer cells. GENETICS AND MOLECULAR RESEARCH 2015; 14:5258-65. [PMID: 26125720 DOI: 10.4238/2015.may.18.17] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The aim of this study was to observe the effects of re-combinant human endostatin on the proliferation and apoptosis of mouse gastric cancer cells, and explore some possible mechanisms of recom-binant human endostatin inhibition of cancer. A murine gastric cancer xenograft model was established. A total of 20 mice were divided into two groups (control and experimental groups). The expression of c-Myc and basic fibroblast growth factor (bFGF) was determined by reverse transcription-polymerase chain reaction, Western blotting, and immu-nohistochemical staining methods. Tumor volume was measured and a growth curve was calculated. The tumor diameter in the experimental group was significantly smaller than that in the control group after treat-ment with endostatin for 21 days. The expression levels of c-Myc and bFGF in the experimental group were significantly lower than those of the control group (P < 0.05). There was a positive correlation between the expression of c-Myc and bFGF in the experimental group. Microvessel density was significantly inhibited in the experimental group (P < 0.05). These results demonstrated that recombinant human endostatin could in-hibit tumor metastasis by inhibition of the expression of c-Myc and bFGF in gastric cancer tissue as well as by inhibition of angiogenesis.
Collapse
|
35
|
Zhu MF, Ye XP, Huang YY, Guo ZY, Zhuang ZF, Liu SH. Detection of methemoglobin in whole blood based on confocal micro-Raman spectroscopy and multivariate statistical techniques. SCANNING 2014; 36:471-478. [PMID: 24729434 DOI: 10.1002/sca.21143] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Accepted: 03/04/2014] [Indexed: 06/03/2023]
Abstract
Raman spectroscopy has been shown to have the potential for revealing oxygenated and spin ability of hemoglobin. In this study, confocal micro-Raman spectroscopy is developed to monitor the effect of sodium nitrite on oxyhemoglobin (HbO2 ) in whole blood. We observe that the band at 1,638 cm(-1) which is sensitive to the oxidation state decreases dramatically, while the 1,586 cm(-1) (low-spin state band) reduces both in methemoglobin (MetHb) and poisoning blood. Our results show that adding in sodium nitrite lead to the transition from HbO2 (Fe(2+) ) to MetHb (Fe(3+) ) in whole blood, and the iron atom converts from the low spin state to the high spin state with a delocalization from porphyrin plane. Moreover, multivariate statistical techniques, including principal components analysis (PCA) and linear discriminant analysis (LDA) are employed to develop effective diagnostic algorithms for classification of spectra between pure blood and poisoning blood. The diagnostic algorithms based on PCA-LDA yield a diagnostic sensitivity of 100% and specificity of 100% for separating poisoning blood from normal blood. Receiver operating characteristic (ROC) curve further confirms the effectiveness of the diagnostic algorithm based on PCA-LDA technique. The results from this study demonstrate that Raman spectroscopy combined with PCA-LDA algorithms has tremendous potential for the non-invasive detection of nitrite poisoning blood.
Collapse
|
36
|
Chen J, Guo ZY, Zhang Y, Liang QZ, Liao HY, Su WR, Tang QY, Fu SX, Chen CX, Han XJ. Longitudinal follow-up of patients with mild traumatic brain injury by magnetic resonance spectroscopic technique. ASIAN PAC J TROP MED 2014; 6:410-2. [PMID: 23608384 DOI: 10.1016/s1995-7645(13)60049-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Revised: 04/15/2013] [Accepted: 05/15/2013] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To explore the changes in the concentrations of neural markers immediately or several months after mild traumatic brain injury (mTBI). METHODS The metabolic markers of neurons in white matter tissues above the lateral ventricle were semi-quantitatively determined by employing 1H magnetic resonance spectroscopic technique (1-H-MRS) in 30 clinically diagnosed cases of mTBI. At the same time, the neurological functions of the subjects, including ability to pay attention, memory, working memory and operational capacity etc were also assessed. RESULTS The patients were followed up for, on average, 13 days after mTBI and the results showed that Cre, PCre and Glx in the white matter tissues were significantly elevated in mTBI patients. 17 patients (57%) recovered from the injury during the follow-up (median was defined as the 40th post-trauma day). Comparison in terms of intelligence among groups revealed that the levels of neural markers of intelligence development was positively related with intelligence scores). CONCLUSIONS Change in Glx concentrations is most sensitive during trauma or in ensuing repairing processes, and might be different from normal status in the following months and Glx level tends to be accompanied with change in Cre, another energy-related marker.
Collapse
|
37
|
Ren HT, Zhao J, Peng SX, Lu PN, Zhou QF, Xu Y, Chen J, Zhang T, Zhang AL, Guo ZY, Chen JE. Handling radiation generated during an ion source commissioning. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A930. [PMID: 24593509 DOI: 10.1063/1.4833925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H(+) ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D(+) beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.
Collapse
|
38
|
Ren HT, Peng SX, Lu PN, Zhao J, Zhou QF, Song ZZ, Yuan ZX, Yu JX, Guo ZY, Chen JE. Commissioning and operation of the deuteron injector for PKUNIFTY project. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A706. [PMID: 24593440 DOI: 10.1063/1.4826337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
PKUNIFTY (PeKing University Neutron Imaging FaciliTY), a thermal neutron imaging facility based on a 2 MeV RFQ accelerator, has been constructed at Peking University. Its deuteron injector, which consists of a 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) deuteron ion source and a two-solenoid low energy beam transport (LEBT), aims at producing and delivering 50 mA, 50 keV deuteron beam with a duty factor of 10% (1 ms, 100 Hz). In the preliminary tests of RFQ accelerator, the ECR ion source and LEBT are required to operate at various duty factors (from 1% to 10%). The deuteron ion source has been tested with different pulse widths for this reason. In order to optimize the transmission parameters, the beam current at the exit of RFQ as a function of solenoids tuning and steering magnets tuning are carefully studied. The beam emittance at the entrance of RFQ has been measured with space charge compensation by different argon gas (RG) pressure from 1.6 × 10(-4) Pa to 4.7 × 10(-3) Pa. The measuring results show the best compensating pressure is 3.5 × 10(-3) Pa with a minimal normalized rms emittance of 0.12 pi mm mrad. During the commissioning, we found the purity of deuteron gas is an important factor which severely affects ECR discharge and plasma intensity inside the ion source chamber. The detailed experimental results obtained during the commissioning are discussed in this paper.
Collapse
|
39
|
Ren HT, Peng SX, Xu Y, Zhao J, Lu PN, Chen J, Zhang AL, Zhang T, Guo ZY, Chen JE. Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02A927. [PMID: 24593506 DOI: 10.1063/1.4832065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ&SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D(+), 10 mA of O(+), 10 mA of He(+), and 50 mA of H(+)). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.
Collapse
|
40
|
Guo ZY, Chen J, Yang G, Tang QY, Chen CX, Fu SX, Yu D. Characteristics of neurovascular compression in facial neuralgia patients by 3D high-resolution MRI and fusion technology. ASIAN PAC J TROP MED 2013. [PMID: 23199722 DOI: 10.1016/s1995-7645(12)60190-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
OBJECTIVE To evaluate the anatomical characteristics and patterns of neurovascular compression in patients suffering trigeminal neuralgia, using 3D high-resolution magnetic resonance imaging methods and fusion technologies. METHODS The analysis of the anatomy of the facial nerve, brain stem and the vascular structures related to this nerve was made in 100 consecutive patients for TN. 3D high resolution MRI studies (3D SPGR, T1 enhanced 3D MP-RAGE and T2/T1 3D FIESTA) simultaneous visualization were used to assessed using the software 3D DOCTOR. RESULTS In 93 patients (93%), there were one or several locals of neurovascular compression (NVC). The superior cerebellar artery was involved in 71 cases (76%), the other vessels including the antero-inferior cerebellar artery, the basilar artery, the vertebral artery, and some venous structures. The mean distance between NVC and nerve origin site in the brainstem was (3.76 ± 2.90) mm). In 39 patients (42%), the vascular compression was located proximally and in 42 (45%) the compression was located distally. Nerve dislocation or distortion by the vessel was observed in 30 cases (32%). CONCLUSIONS This 3D high resolution MRI and image fusion technology could be useful for diagnostic and therapeutic decisions in TN.
Collapse
|
41
|
Xiong HL, Guo ZY, Li SX, Li N, Liu SH, Ji YH. In vivo detection of Hirschsprung's disease by optical coherence tomography in rats. Phys Med Biol 2013; 58:1549-61. [PMID: 23417024 DOI: 10.1088/0031-9155/58/5/1549] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Hirschsprung's disease (HSCR) is a developmental intestinal obstruction, which is often diagnosed with a repeated biopsy. Optical coherence tomography (OCT) is a noninvasive, real-time imaging modality. This study aims to investigate the feasibility of diagnosis of HSCR, the targeted biopsies of suspicious tissues and the location of operative treatment using OCT. An HSCR Sprague-Dawley (SD) rat model (benzalkonium chloride-treated (BAC-treated)) was used. Colon tissues with BAC-treated and without BAC-treated were imaged using OCT. To establish OCT criteria for identification of HSCR, OCT images were compared with corresponding histology images and muscle layer thickness was measured. Furthermore, attenuation coefficients of OCT signals were calculated to illustrate the differences between tissues with BAC-treated and without BAC-treated. Our results show that OCT images of colon tissues with HSCR are well correlated with histology images. In comparison with a muscle layer without HSCR, the thickness of muscle layer with HSCR is increased significantly. The muscle layer in colon tissues with HSCR for 6 weeks had a higher attenuation coefficient than those without HSCR. However, the attenuation coefficient of those with HSCR for 3 weeks had no obvious change. In conclusion, the study demonstrates for the first time that OCT has the potential for diagnosis, biopsy and location of HSCR in vivo.
Collapse
|
42
|
Guo ZY, Chen J, Liang QZ, Liao HY, Cheng QY, Fu SX, Chen CX, Yu D. RETRACTED: High-resolution MRI of cranial nerves in posterior fossa at 3.0 T. ASIAN PAC J TROP MED 2013; 6:159-61. [DOI: 10.1016/s1995-7645(13)60015-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 11/27/2012] [Accepted: 12/28/2012] [Indexed: 10/27/2022] Open
|
43
|
Zhuang ZF, Zhu MF, Guo ZY, Liu SH. Second harmonic generation in 3-d uniform arrangement of type I collagen on nonlinear optics microscopy. SCANNING 2013; 35:12-16. [PMID: 23417663 DOI: 10.1002/sca.21029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Accepted: 04/15/2012] [Indexed: 06/01/2023]
Abstract
Second harmonic microscopic imaging and spectroscopy technology has become a powerful tool for biomedical studies, especially in fibrosis-related diseases research. And type I collagen is the major risk factors for fibrotic diseases. In this study, model for three-dimensional (3-D) uniform arrangement type I collagen is set up for researching the second harmonic generation (SHG) on nonlinear optics microscopy. Based on this model, we discuss the influence of different length and size collagen in 3-D arrangement type I collagen. Results can guide us to neatly judge the size, length, and molecules density effect on SHG. For practical application, this theoretical approach can lead us to analyze different severity of collagen diseases.
Collapse
|
44
|
Guo ZY, Chen J, Liang QZ, Liao HY, Fu SX, Tang QY, Chen CX, Han XJ, Gao F. Comparison between magnitude reconstruction and phase-sensitive mR imaging in the detection of myocardial infarction. ASIAN PAC J TROP MED 2012; 5:911-3. [PMID: 23146808 DOI: 10.1016/s1995-7645(12)60170-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2012] [Revised: 09/27/2012] [Accepted: 10/28/2012] [Indexed: 10/27/2022] Open
Abstract
OBJECTIVE To determine the deference between phase sensitive magnetic resonance (MR) imaging and magnitude reconstruction to detect infracted myocardium. METHODS Twenty patients (16 men; 4 women; mean age, 56 years). experienced Q-wave myocardial infarction 2 weeks earlier were examined with a 3.0-T MR system 10 minutes after administration of 0.1 mmol/kg body weight gadobenate dimeglumine. To determine the optimal TI, a TI scout sequence was used. A segmented 2D IR true fast imaging with steady-state precession (trueFISP) sequence that produces both phase-sensitive and magnitude-reconstructed images were used at TI values of 200-600 msec (TI values were varied in 100-msec steps) and at optimal TI (mean value, 330 msec). Contrast-noise ratios (CNRs) of normal and infarcted myocardium and the area of infarcted myocardium were determined. Two-tailed unpaired sample Student t test was used to compare CNRs, and area of infarction. RESULTS MMean CNR phase-sensitive and magnitude-reconstructed images at optimal TI (mean value, 330 msec) were 6.2, and 6.1, respectively. For a TI of 200 msec, CNR values were 5.5, and 4.2, respectively; for TI of 600 msec, CNR values were 5.8 and 4.3, respectively. Area of infarcted myocardium was underestimated on magnitude-reconstruction images (P = 0.002-0.03) for short TI values (ie., 200 msec) but not on phase sensitive reconstructed when compared with IR tureFISP images obtained at optimal TI. CONCLUSIONS LPhase-sensitive image reconstruction results in reduced need for precise choice of TI and more consistent image quality.
Collapse
|
45
|
Chen J, Guo ZY, Yang G, Wang X, Tang QY, Cheng YQ, Guo Y, Fu SX, Chen CX, Han XJ. RETRACTED: Characterization of neurovascular compression in facial neuralgia patients by 3D high-resolution MRI and image fusion technique. ASIAN PAC J TROP MED 2012; 5:476-9. [DOI: 10.1016/s1995-7645(12)60082-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2012] [Revised: 03/15/2012] [Accepted: 04/15/2012] [Indexed: 11/26/2022] Open
|
46
|
Li N, Li SX, Guo ZY, Zhuang ZF, Li R, Xiong K, Chen SJ, Liu SH. Micro-Raman spectroscopy study of the effect of Mid-Ultraviolet radiation on erythrocyte membrane. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY 2012; 112:37-42. [PMID: 22561009 DOI: 10.1016/j.jphotobiol.2012.04.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2012] [Revised: 03/30/2012] [Accepted: 04/04/2012] [Indexed: 12/14/2022]
Abstract
Mid-Ultraviolet (UVB) has a significant influence on human health. In this study, human erythrocytes were exposed to UVB to investigate the effects of UVB radiation on erythrocytes membrane. And Micro-Raman spectroscopy was employed to detect the damage. Principal component analysis (PCA) was used to classify the control erythrocytes and the irradiated erythrocytes. Results showed that the erythrocytes membrane was damaged by Mid-Ultraviolet (UVB) radiation. The intensity of the Raman peaks at 1126 cm(-1) and 1082 cm(-1) were used to calculate the Longitudinal Order-Parameters in Chains (S(trans)) which can present the liquidity and ionic permeability of erythrocyte membrane. After UVB radiation for 30 min, both the liquidity and ionic permeability decreased. At the same time, the intensity of the peaks at 1302 cm(-1) (α-helix), 1254 cm(-1) (random coil), 1452 cm(-1) and 1430 cm(-1) (CH(2)/CH(3) stretch) have also changed which indicated the membrane protein also been damaged by UVB. In the whole process of radiation, the more UVB radiation dose the more damage on the erythrocyte membrane.
Collapse
|
47
|
Ren HT, Peng SX, Lu PN, Yan S, Zhou QF, Zhao J, Yuan ZX, Guo ZY, Chen JE. Intense beams from gases generated by a permanent magnet ECR ion source at PKU. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B905. [PMID: 22380337 DOI: 10.1063/1.3669788] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
An electron cyclotron resonance (ECR) ion source is designed for the production of high-current ion beams of various gaseous elements. At the Peking University (PKU), the primary study is focused on developing suitable permanent magnet ECR ion sources (PMECRs) for separated function radio frequency quadrupole (SFRFQ) accelerator and for Peking University Neutron Imaging Facility. Recently, other kinds of high-intensity ion beams are required for new acceleration structure demonstration, simulation of fusion reactor material irradiation, aviation bearing modification, and other applications. So we expanded the ion beam category from O(+), H(+), and D(+) to N(+), Ar(+), and He(+). Up to now, about 120 mA of H(+), 83 mA of D(+), 50 mA of O(+), 63 mA of N(+), 70 mA of Ar(+), and 65 mA of He(+) extracted at 50 kV through a φ 6 mm aperture were produced by the PMECRs at PKU. Their rms emittances are less than 0.2 π mm mrad. Tungsten samples were irradiated by H(+) or He(+) beam extracted from this ion source and H∕He holes and bubbles have been observed on the samples. A method to produce a high intensity H∕He mixed beam to study synergistic effect is developed for nuclear material irradiation. To design a He(+) beam injector for coupled radio frequency quadruple and SFRFQ cavity, He(+) beam transmission experiments were carried out on PKU low energy beam transport test bench and the transmission was less than 50%. It indicated that some electrode modifications must be done to decrease the divergence of He(+) beam.
Collapse
|
48
|
Ren HT, Peng SX, Lu PN, Zhou QF, Yuan ZX, Zhao J, Zhang M, Song ZZ, Yu JX, Guo ZY, Chen JE. Deuteron injector for Peking University Neutron Imaging Facility project. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B711. [PMID: 22380316 DOI: 10.1063/1.3670345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The deuteron injector developed for the PKUNIFTY (Peking University Neutron Imaging Facility) has been installed and commissioned at Peking University (PKU). The injector system must transfer 50 keV 50 mA of D(+) ion beam to the entrance of the 2 MeV radio frequency quadrupole (RFQ) with 10% duty factor (1 ms, 100 Hz). A compact 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) ion source and a 1.36 m long low energy beam transport (LEBT) line using two solenoids was developed as the deuteron injector. A φ5 mm four-quadrant diaphragm was used to simulate the entrance of RFQ electrodes. The beam parameters are measured after this core with an emittance measurement unit (EMU) and a bending magnet for ion fraction analysis at the end of injector. During the commissioning, 77 mA of total deuteron beam was extracted from PMECR and 56 mA of pure D(+) beam that passed through the φ5 mm four-quadrant diaphragm was obtained at the position of RFQ entrance with the measured normalized rms emittance 0.12-0.16π mm mrad. Ion species analysis results show that the deuteron fraction is as high as 99.5%. All of the parameters satisfy PKUNIFTY's requirements. In this paper, we will describe the deuteron injector design and report the commissioning results as well as the initial operation.
Collapse
|
49
|
Wang HY, Lin C, Sheng ZM, Liu B, Zhao S, Guo ZY, Lu YR, He XT, Chen JE, Yan XQ. Laser shaping of a relativistic intense, short Gaussian pulse by a plasma lens. PHYSICAL REVIEW LETTERS 2011; 107:265002. [PMID: 22243161 DOI: 10.1103/physrevlett.107.265002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2011] [Indexed: 05/31/2023]
Abstract
By 3D particle-in-cell simulation and analysis, we propose a plasma lens to make high intensity, high contrast laser pulses with a steep front. When an intense, short Gaussian laser pulse of circular polarization propagates in near-critical plasma, it drives strong currents of relativistic electrons which magnetize the plasma. Three pulse shaping effects are synchronously observed when the laser passes through the plasma lens. The laser intensity is increased by more than 1 order of magnitude while the initial Gaussian profile undergoes self-modulation longitudinally and develops a steep front. Meanwhile, a nonrelativistic prepulse can be absorbed by the overcritical plasma lens, which can improve the laser contrast without affecting laser shaping of the main pulse. If the plasma skin length is properly chosen and kept fixed, the plasma lens can be used for varied laser intensity above 10(19) W/cm(2).
Collapse
|
50
|
Ren HT, Peng SX, Zhang M, Zhou QF, Song ZZ, Yuan ZX, Lu PN, Xu R, Zhao J, Yu JX, Lu YR, Guo ZY, Chen JE. The deuteron injector progress of the Peking University Neutron Imaging Facility project. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:02B714. [PMID: 20192454 DOI: 10.1063/1.3273078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A deuteron radio frequency quadrupoles injector h has been developed at Peking University. A permanent magnetic electron cyclotron resonance (ECR) ion source is used in the injector system. A 50 keV 100 mA proton beam has been extracted from the ECR ion source and the measured normalized rms emittance is 0.11-0.14pi mm mrad. A deuteron beam has also been extracted at 50 kV with 83 mA total current and its emittance is less than 0.18pi mm mrad. The proton beam transmission has been investigated on a low energy beam transport test bench, and up to 93% transmission can be reached. The new injector with two solenoids has been designed and is being constructed. All the development results will be presented in this paper.
Collapse
|