26
|
Pan W, Huang Q, Zhou L, Lin J, Du X, Qian X, Jiang T, Chen W. Epigenetic age acceleration and risk of aortic valve stenosis: a bidirectional Mendelian randomization study. Clin Epigenetics 2024; 16:41. [PMID: 38475866 PMCID: PMC10936111 DOI: 10.1186/s13148-024-01647-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Accepted: 02/19/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND Aortic valve stenosis (AVS) is the most prevalent cardiac valve lesion in developed countries, and pathogenesis is closely related to aging. DNA methylation-based epigenetic clock is now recognized as highly accurate predictor of the aging process and associated health outcomes. This study aimed to explore the causal relationship between epigenetic clock and AVS by conducting a bidirectional Mendelian randomization (MR) analysis. METHODS Summary genome-wide association study statistics of epigenetic clocks (HannumAge, HorvathAge, PhenoAge, and GrimAge) and AVS were obtained and assessed for significant instrumental variables from Edinburgh DataShare (n = 34,710) and FinnGen biobank (cases = 9870 and controls = 402,311). The causal association between epigenetic clock and AVS was evaluated using inverse variance weighted (IVW), weighted median (WM), and MR-Egger methods. Multiple analyses (heterogeneity analysis, pleiotropy analysis, and sensitivity analysis) were performed for quality control assessment. RESULTS The MR analysis showed that the epigenetic age acceleration of HorvathAge and PhenoAge was associated with an increased risk of AVS (HorvathAge: OR = 1.043, P = 0.016 by IVW, OR = 1.058, P = 0.018 by WM; PhenoAge: OR = 1.058, P = 0.005 by IVW, OR = 1.053, P = 0.039 by WM). Quality control assessment proved our findings were reliable and robust. However, there was a lack of evidence supporting a causal link from AVS to epigenetic aging. CONCLUSION The present MR analysis unveiled a causal association between epigenetic clocks, especially HorvathAge and PhenoAge, with AVS. Further research is required to elucidate the underlying mechanisms and develop strategies for potential interventions.
Collapse
|
27
|
Beyer M, Demal TJ, Bhadra OD, Linder M, Ludwig S, Grundmann D, Voigtlaender-Buschmann L, Waldschmidt L, Schirmer J, Schofer N, Pecha S, Blankenberg S, Reichenspurner H, Conradi L, Seiffert M, Schaefer A. Transcatheter aortic valve implantation in patients with significant septal hypertrophy. Clin Res Cardiol 2024:10.1007/s00392-024-02432-3. [PMID: 38466346 DOI: 10.1007/s00392-024-02432-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 02/29/2024] [Indexed: 03/13/2024]
Abstract
BACKGROUND Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.
Collapse
|
28
|
Sanoussi A, Aminian A, Abi-Khalil J. One-stop transcatheter aortic valve replacement and fenestrated endovascular aortic aneurysm repair: A case report. Radiol Case Rep 2024; 19:1162-1165. [PMID: 38259706 PMCID: PMC10801146 DOI: 10.1016/j.radcr.2023.12.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/16/2023] [Accepted: 12/20/2023] [Indexed: 01/24/2024] Open
Abstract
The management of patients with severe aortic valve stenosis and an abdominal aortic aneurysm is a real therapeutic challenge. Minimally invasive treatment is more beneficial than open surgery for treating both aortic valve stenosis and abdominal aortic aneurysm. We present a case of a 77-year-old male initially treated with a 26 mm Sapien 3 transcatheter aortic valve replacement. Subsequently, using the same femoral access points, a custom fenestrated endoprosthesis and stents in digestive trunks and renal arteries were implanted. Follow-up imaging revealed no dysfunction of the valve, endoprosthesis, or stents. This is the first reported successful concomitant management of significant aortic valve stenosis and infrarenal abdominal aortic aneurysm through transcatheter aortic valve replacement and fenestrated endovascular aortic aneurysm repair.
Collapse
|
29
|
Nielsen MB, Çolak Y, Benn M, Mason A, Burgess S, Nordestgaard BG. Plasma adiponectin levels and risk of heart failure, atrial fibrillation, aortic valve stenosis, and myocardial infarction: large-scale observational and Mendelian randomization evidence. Cardiovasc Res 2024; 120:95-107. [PMID: 37897683 PMCID: PMC10898934 DOI: 10.1093/cvr/cvad162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 09/07/2023] [Accepted: 09/23/2023] [Indexed: 10/30/2023] Open
Abstract
AIMS Adiponectin may play an important protective role in heart failure and associated cardiovascular diseases. We hypothesized that plasma adiponectin is associated observationally and causally, genetically with risk of heart failure, atrial fibrillation, aortic valve stenosis, and myocardial infarction. METHODS AND RESULTS In the Copenhagen General Population Study, we examined 30 045 individuals with plasma adiponectin measurements observationally and 96 903 individuals genetically in one-sample Mendelian randomization analyses using five genetic variants explaining 3% of the variation in plasma adiponectin. In the HERMES, UK Biobank, The Nord-Trøndelag Health Study (HUNT), deCODE, the Michigan Genomics Initiative (MGI), DiscovEHR, and the AFGen consortia, we performed two-sample Mendelian randomization analyses in up to 1 030 836 individuals using 12 genetic variants explaining 14% of the variation in plasma adiponectin.In observational analyses modelled linearly, a 1 unit log-transformed higher plasma adiponectin was associated with a hazard ratio of 1.51 (95% confidence interval: 1.37-1.66) for heart failure, 1.63 (1.50-1.78) for atrial fibrillation, 1.21 (1.03-1.41) for aortic valve stenosis, and 1.03 (0.93-1.14) for myocardial infarction; levels above the median were also associated with an increased risk of myocardial infarction, and non-linear U-shaped associations were more apparent for heart failure, aortic valve stenosis, and myocardial infarction in less-adjusted models. Corresponding genetic, causal risk ratios were 0.92 (0.65-1.29), 0.87 (0.68-1.12), 1.55 (0.87-2.76), and 0.93 (0.67-1.30) in one-sample Mendelian randomization analyses, and no significant associations were seen for non-linear one-sample Mendelian randomization analyses; corresponding causal risk ratios were 0.99 (0.89-1.09), 1.00 (0.92-1.08), 1.01 (0.79-1.28), and 0.99 (0.86-1.13) in two-sample Mendelian randomization analyses, respectively. CONCLUSION Observationally, elevated plasma adiponectin was associated with an increased risk of heart failure, atrial fibrillation, aortic valve stenosis, and myocardial infarction. However, genetic evidence did not support causality for these associations.
Collapse
|
30
|
Kapadia SJ, Salmasi MY, Zientara A, Roussin I, Quarto C, Asimakopoulos G. Perceval sutureless bioprosthesis versus Perimount sutured bioprosthesis for aortic valve replacement in patients with aortic stenosis: a retrospective, propensity-matched study. J Cardiothorac Surg 2024; 19:95. [PMID: 38355617 PMCID: PMC10865583 DOI: 10.1186/s13019-024-02575-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 01/30/2024] [Indexed: 02/16/2024] Open
Abstract
BACKGROUND Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.
Collapse
|
31
|
Ziewers S, Fischer ND, Börner JH, Kaufmann L, Tamm A, Yang Y, Jungmann F, Dotzauer R, Sparwasser P, Hoefner T, Tsaur I, Haferkamp A, Mager R. Clinical Impact and Management of Incidental Renal Findings on Pre-TAVI CT Scan from the Urologist's Perspective. Urol Int 2024; 108:219-225. [PMID: 38354722 DOI: 10.1159/000537808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 01/31/2024] [Indexed: 02/16/2024]
Abstract
INTRODUCTION The aim of the study was to investigate prevalence and impact of incidental renal masses (IRMs) accompanying increasing computed tomography (CT) work-up for symptomatic aortic valve stenosis (sAVS) of the elderly with regard to the relevance of urological consultation for overall survival (OS). METHODS A retrospective analysis of pre-transcatheter aortic-valve implantations (TAVIs) CT scans of patients with sAVS (N = 1,253) harboring IRM was performed for 2014-2019. According to the clinical management, groups 1 (urologic consultation) and 2 (findings ignored) were formed and analyzed in terms of OS. RESULTS The prevalence of IRM was 9% (119/1,253). In 19% (23/119), urological advice was sought (group 1). At baseline, group 1 showed a significantly higher rate of malignancy-specific lesions compared to 2 (p < 0.01). Other clinical parameters (e.g., age, cardiological scores, comorbidities) did not differ between groups (p > 0.05). In group 1, 4 (17%) findings were histologically confirmed, of which 3 (13%) underwent surgery. There was no significant difference in median OS at a median follow-up of 24.7 months between groups 1 and 2 with 35.7 (95% CI, 5.9; 65.4) and 47.4 months (95% CI, 33.0; 61.7), respectively (p = 0.4). In Cox regression analysis, chronic kidney disease but not urologic work-up or chronic obstructive pulmonary disease or heart failure emerged as an independent unfavorable predictor of OS (HR 2.44, 95% CI 1.37; 4.36, p = 0.003). CONCLUSION For the first time, a TAVI population with IRM was analyzed from the urologist's perspective. Urologic co-evaluation and work-up does not confer a significant benefit in terms of OS in this particular population.
Collapse
|
32
|
Yoshida K, Miura Y, Fukunaga Y, Mitsuishi A. A Y-incision to enlarge the aortic root for aortic valve stenosis with anomalous aortic origin of the right coronary artery. J Cardiothorac Surg 2024; 19:54. [PMID: 38311727 PMCID: PMC10840288 DOI: 10.1186/s13019-024-02518-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 01/28/2024] [Indexed: 02/06/2024] Open
Abstract
BACKGROUND Anomalous aortic origin of the coronary artery (AAOCA) is a rare congenital heart disease. Therefore, optimal indications for surgery in patients with severe aortic valve stenosis (AS) complicated by AAOCA remain uncertain. CASE PRESENTATION We report the case of a 57-year-old male patient who underwent aortic valve replacement (AVR) and aortic root enlargement using a Y-incision procedure for severe AS with an anomalous aortic origin of the right coronary artery (AAORCA). Since preoperative single-photon emission computed tomography revealed no ischaemic lesions, an aortic root enlargement with a Y-incision was performed to prevent the potential compression of the prosthetic valve on the AAOCA and prosthesis-patient mismatch. CONCLUSIONS Preoperative evaluation of the coronary anatomy and myocardial ischaemia using advanced imaging modalities and aortic root enlargement with the Y-incision procedure is an effective strategy for preventing ischaemic complications in cases of severe AS with AAORCA.
Collapse
|
33
|
García-Blas S, Pernias V, González D'gregorio J, Fernández-Cisnal A, Bonanad C, Sastre C, Valero E, Miñana G, Zaharia G, Núñez J, Sanchis J. Carbohydrate antigen 125-guided pre-TAVI medical optimization: impact on quality of life and clinical outcomes. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2024:S1885-5857(24)00037-9. [PMID: 38311024 DOI: 10.1016/j.rec.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 01/17/2024] [Indexed: 02/06/2024]
Abstract
INTRODUCTION AND OBJECTIVES Carbohydrate antigen 125 (CA125), a biomarker associated with fluid overload, has proven useful in managing diuretic therapy in heart failure. We aimed to evaluate the impact of diuretic optimization guided by CA125 before transcatheter aortic valve implantation (TAVI) on outcomes. METHODS This prospective interventional study enrolled patients scheduled for TAVI, in whom baseline CA125 was measured 2 weeks before TAVI. Patients with CA125 ≥ 20 U/mL underwent diuretic up-titration before TAVI. Three groups were included: group I) baseline CA125 <20 U/mL; IIa) CA125 ≥ 20 U/mL that decreased after treatment, and IIb) CA125 ≥ 20 U/mL that did not decrease. The primary outcome was changes in the Kansas City Cardiomyopathy Questionnaire at 3 and 12 months. The secondary endpoint was clinical events. RESULTS The study included 184 patients (115 group I, 46 IIa, and 23 IIb). Groups I and IIa exhibited early and sustained improvements in the Kansas City Cardiomyopathy Questionnaire (group I: 18.9 points [95%CI, 15.7-22.1; P <.001] at 90 days, and 18.1 [95%CI, 14.9-21.4, P <.001] at 1 year; group IIa: 21.1 points [95%CI, 15.4-26.7; P <.001] and 19.5 [95%CI, 13.9-25.1; P <.001] respectively). In contrast, in group IIb there was no significant improvement at 90 days (P=.12), with improvement being significant only at 1 year (17.8 points, 95%CI, 5.9-29.6; P=.003). Over a median follow-up of 20.7 months, there were 63 (27.83%) deaths or heart failure admissions. Multivariate analysis showed a lower risk of events in group I vs IIb (HR, 0.28; 95%CI, 0.14-0.58; P <.001), and IIa vs IIb (HR, 0.24; 95%CI, 0.11-0.55; P <.001). CONCLUSIONS Patients with persistently high CA125 despite diuretic therapy pre-TAVI showed slower functional recovery and poorer clinical outcomes after TAVI.
Collapse
|
34
|
Lee SH, Oh S, Ko YG, Lee YJ, Lee SJ, Hong SJ, Ahn CM, Kim JS, Kim BK, Ko KY, Cho I, Shim CY, Hong GR, Choi D, Hong MK. Comparison of Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance During Transcatheter Aortic Valve Replacement. Korean Circ J 2024; 54:63-75. [PMID: 38111184 PMCID: PMC10864253 DOI: 10.4070/kcj.2023.0195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/18/2023] [Accepted: 10/11/2023] [Indexed: 12/20/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Evidence regarding the efficacy and safety of intracardiac echocardiography (ICE) for guidance during transcatheter aortic valve replacement (TAVR) is limited. This study aimed to compare the clinical efficacy and safety of ICE versus transesophageal echocardiography (TEE) for guiding TAVR. METHODS This prospective cohort study included patients who underwent TAVR from August 18, 2015, to June 31, 2021. Eligible patients were stratified by echocardiographic modality (ICE or TEE) and anesthesia mode (monitored anesthesia care [MAC] or general anesthesia [GA]). Primary outcome was the 1-year composite of all-cause mortality, rehospitalization for cardiovascular cause, or stroke, according to the Valve Academic Research Consortium-3 (VARC-3) definition. Propensity score matching was performed, and study outcomes were analyzed for the matched cohorts. RESULTS Of the 359 eligible patients, 120 patients were matched for the ICE-MAC and TEE-GA groups, respectively. The incidence of primary outcome was similar between matched groups (18.3% vs. 20.0%; adjusted hazard ratio, 0.94; 95% confidence interval [CI], 0.53-1.68; p=0.843). ICE-MAC and TEE-GA also had similar incidences of moderate-to-severe paravalvular regurgitation (PVR) (4.2% vs. 5.0%; adjusted odds ratio, 0.83; 95% CI, 0.23-2.82; p=0.758), new permanent pacemaker implantation, and VARC-3 types 2-4 bleeding. CONCLUSIONS ICE was comparable to TEE for guidance during TAVR for the composite clinical efficacy outcome, with similar incidences of moderate-to-severe PVR, new permanent pacemaker implantation, and major bleeding. These results suggest that ICE could be a safe and effective alternative echocardiographic modality to TEE for guiding TAVR.
Collapse
|
35
|
Govindarajan V, Kolanjiyil A, Wanna C, Kim H, Prakash S, Chandran KB, McPherson DD, Johnson NP. Biomechanical Evaluation of Aortic Valve Stenosis by Means of a Virtual Stress Test: A Fluid-Structure Interaction Study. Ann Biomed Eng 2024; 52:414-424. [PMID: 37957528 DOI: 10.1007/s10439-023-03389-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 10/15/2023] [Indexed: 11/15/2023]
Abstract
The impact of aortic valve stenosis (AS) extends beyond the vicinity of the narrowed leaflets into the left ventricle (LV) and into the systemic vasculature because of highly unpredictable valve behavior and complex blood flow in the ascending aorta that can be attributed to the strong interaction between the narrowed cusps and the ejected blood. These effects can become exacerbated during exercise and may have implications for disease progression, accurate diagnosis, and timing of intervention. In this 3-D patient-specific study, we employ strongly coupled fluid-structure interaction (FSI) modeling to perform a comprehensive biomechanical evaluation of systolic ejection dynamics in a stenosed aortic valve (AV) during increasing LV contraction. Our model predictions reveal that the heterogeneous ∆P vs. Q relationship that was observed in our previous clinical study can be attributed to a non-linear increase (by ~ 1.5-fold) in aortic valve area as LV heart rate increases from 70 to 115 bpm. Furthermore, our results show that even for a moderately stenotic valve, increased LV contraction during exercise can lead to high-velocity flow turbulence (Re = 11,700) in the aorta similar to that encountered with a severely stenotic valve (Re ~ 10,000), with concomitant greater viscous loss (~3-fold increase) and elevated wall stress in the ascending aorta. Our FSI predictions also reveal that individual valve cusps undergo distinct and highly non-linear increases (>100%) in stress during exercise, potentially contributing to progressive calcification. Such quantitative biomechanical evaluations from realistic FSI workflows provide insights into disease progression and can be integrated with current stress testing for AS patients to comprehensively predict hemodynamics and valve function under both baseline and exercise conditions.
Collapse
|
36
|
Santos-Ferreira D, Fernandes I, Diaz SO, Guerreiro C, Saraiva F, Barros AS, Leite-Moreira A, Pereira E, Sampaio F, Ribeiro J, Braga P, Fontes-Carvalho R. Prognostic value of flow-status in severe aortic stenosis patients undergoing percutaneous intervention. Int J Cardiovasc Imaging 2024; 40:341-350. [PMID: 37981631 PMCID: PMC10884040 DOI: 10.1007/s10554-023-02992-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 10/21/2023] [Indexed: 11/21/2023]
Abstract
PURPOSE Low-flow status is a mortality predictor in severe aortic stenosis (SAS) patients, including after transcatheter aortic valve implantation (TAVI) treatment. However, the best parameter to assess flow is unknown. Recent studies suggest that transaortic flow rate (FR) is superior to currently used stroke volume index (SVi) in defining low-flow states. Therefore, we aimed to evaluate the prognostic value of FR and SVi in patients undergoing TAVI. METHODS A single-centre retrospective analysis of all consecutive patients treated with TAVI for SAS between 2011 and 2019 was conducted. Low-FR was defined as < 200 mL/s and low-SVi as < 35 mL/m2. Primary endpoint was all-cause five-year mortality, analyzed using Kaplan-Meier curves and Cox regression models. Secondary endpoint was variation of NYHA functional class six months after procedure. Patients were further stratified according to ejection fraction (EF < 50%). RESULTS Of 489 cases, 59.5% were low-FR, and 43.1% low-SVi. Low-flow patients had superior surgical risk, worse renal function, and had a higher prevalence of coronary artery disease. Low-FR was associated with mortality (hazard ratio 1.36, p = 0.041), but not after adjustment to EuroSCORE II. Normal-SVi was not associated with survival, despite a significative p-trend for its continuous value. No associations were found for flow-status and NYHA recovery. When stratifying according to preserved and reduced EF, both FR and SVi did not predict all-cause mortality. CONCLUSION In patients with SAS undergoing TAVI, a low-FR state was associated with higher mortality, as well as SVi, but not at a 35 mL/m2 cut off.
Collapse
|
37
|
Verma Y, Arachchige ASPM. Revolutionizing cardiovascular care: the power of histotripsy. J Ultrasound 2024:10.1007/s40477-023-00848-7. [PMID: 38217765 DOI: 10.1007/s40477-023-00848-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 11/13/2023] [Indexed: 01/15/2024] Open
Abstract
Histotripsy, an innovative ultrasonic technique, is poised to transform the landscape of cardiovascular disease management. This review explores the multifaceted applications of histotripsy across various domains of cardiovascular medicine. In thrombolysis, histotripsy presents a non-invasive, drug-free, and precise method for recanalizing blood vessels obstructed by clots, minimizing the risk of vessel damage and embolism. Additionally, histotripsy showcases its potential in congenital heart defect management, offering a promising alternative to invasive procedures by creating intracardiac communications noninvasively. For patients with calcified aortic stenosis, histotripsy demonstrates its effectiveness in softening calcified bioprosthetic valves, potentially revolutionizing valve interventions. In the realm of arrhythmias, histotripsy could play an important role in scar-based ventricular tachycardia ablation, eliminating channel-like isthmuses of slowly conducting myocardium. Histotripsy`s potential applications also extend to structural heart interventions, enabling the safe sectioning of basal chordae and potentially addressing mitral regurgitation. Furthermore, it showcases its versatility by safely generating ventricular septal defects, providing a non-invasive means of creating intracardiac communications in neonates with congenital heart disease. Yet, most supporting studies are in-vitro or animal studies and there are possible challenges in translating experimental data on cardiac histotripsy to the clinical level. As histotripsy continues to evolve and mature, its remarkable potential in cardiovascular disease management holds promise for improving patient outcomes and reducing the burden of invasive procedures in the field of cardiology.
Collapse
|
38
|
Langenbach MC, Langenbach IL, Foldyna B, Mauri V, Klein K, Macherey-Meyer S, Heyne S, Meertens M, Lee S, Baldus S, Maintz D, Halbach M, Adam M, Wienemann H. Advanced CT measures of coronary artery disease with intermediate stenosis in patients with severe aortic valve stenosis. Eur Radiol 2024:10.1007/s00330-023-10549-8. [PMID: 38189982 DOI: 10.1007/s00330-023-10549-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/20/2023] [Accepted: 12/04/2023] [Indexed: 01/09/2024]
Abstract
BACKGROUND Coronary artery disease (CAD) and severe aortic valve stenosis (AS) frequently coexist. While pre-transcatheter aortic valve replacement (TAVR) computed tomography angiography (CTA) allows to rule out obstructive CAD, interpreting hemodynamic significance of intermediate stenoses is challenging. This study investigates the incremental value of CT-derived fractional flow reserve (CT-FFR), quantitative coronary plaque characteristics (e.g., stenosis degree, plaque volume, and composition), and peri-coronary adipose tissue (PCAT) density to detect hemodynamically significant lesions among those with AS and CAD. MATERIALS AND METHODS We included patients with severe AS and intermediate coronary lesions (20-80% diameter stenosis) who underwent pre-TAVR CTA and invasive coronary angiogram (ICA) with resting full-cycle ratio (RFR) assessment between 08/16 and 04/22. CTA image analysis included assessment of CT-FFR, quantitative coronary plaque analysis, and PCAT density. Coronary lesions with RFR ≤ 0.89 indicated hemodynamic significance as reference standard. RESULTS Overall, 87 patients (age 77.9 ± 7.4 years, 38% female) with 95 intermediate coronary artery lesions were included. CT-FFR showed good discriminatory capacity (area under receiver operator curve (AUC) = 0.89, 95% confidence interval (CI) 0.81-0.96, p < 0.001) to identify hemodynamically significant lesions, superior to anatomical assessment, plaque morphology, and PCAT density. Plaque composition and PCAT density did not differ between lesions with and without hemodynamic significance. Univariable and multivariable analyses revealed CT-FFR as the only predictor for functionally significant lesions (odds ratio 1.28 (95% CI 1.17-1.43), p < 0.001). Overall, CT-FFR ≤ 0.80 showed diagnostic accuracy, sensitivity, and specificity of 88.4% (95%CI 80.2-94.1), 78.5% (95%CI 63.2-89.7), and 96.2% (95%CI 87.0-99.5), respectively. CONCLUSION CT-FFR was superior to CT anatomical, plaque morphology, and PCAT assessment to detect functionally significant stenoses in patients with severe AS. CLINICAL RELEVANCE STATEMENT CT-derived fractional flow reserve in patients with severe aortic valve stenosis may be a useful tool for non-invasive hemodynamic assessment of intermediate coronary lesions, while CT anatomical, plaque morphology, and peri-coronary adipose tissue assessment have no incremental or additional benefit. These findings might help to reduce pre-transcatheter aortic valve replacement invasive coronary angiogram. KEY POINTS • Interpreting the hemodynamic significance of intermediate coronary stenoses is challenging in pre-transcatheter aortic valve replacement CT. • CT-derived fractional flow reserve (CT-FFR) has a good discriminatory capacity in the identification of hemodynamically significant coronary lesions. • CT-derived anatomical, plaque morphology, and peri-coronary adipose tissue assessment did not improve the diagnostic capability of CT-FFR in the hemodynamic assessment of intermediate coronary stenoses.
Collapse
|
39
|
Oettinger V, Hilgendorf I, Wolf D, Rilinger J, Maier A, Zehender M, Westermann D, Kaier K, von Zur Mühlen C. Comparing balloon-expandable and self-expanding transfemoral transcatheter aortic valve replacement based on subgroups in Germany 2019/2020. Clin Res Cardiol 2024; 113:168-176. [PMID: 37982864 PMCID: PMC10808194 DOI: 10.1007/s00392-023-02326-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 10/16/2023] [Indexed: 11/21/2023]
Abstract
BACKGROUND Previously, overall comparable outcomes were seen for balloon-expandable (BE) or self-expanding (SE) transfemoral transcatheter aortic valve replacement (TAVR). However, subgroup analyses based on large case numbers are still needed. METHODS German national data of all BE and SE transfemoral TAVR treating aortic valve stenosis in 2019 and 2020 were analysed. We then compared different outcomes and performed a subgroup analysis for the endpoint in-hospital mortality. RESULTS Overall, 46,243 TAVR were analysed, 19,910 BE, and 26,333 SE. Patients in the SE group had a significantly higher logistic EuroSCORE (13.61 vs 12.66%, p < 0.001), age (81.55 vs 79.99a, p < 0.001), and proportion of women (54.82 vs 40.06%, p < 0.001). Both groups showed a similar in-hospital mortality with 2.37% in BE and 2.35% in SE (p = 0.916). In-hospital mortality also did not differ significantly after risk adjustment (OR = 0.98 [0.86, 1.13], p = 0.799). Patients in the SE group had a significantly lower risk of major bleeding (OR = 0.83 [0.73, 0.95], p = 0.006), but a significantly higher risk of stroke (OR = 1.38 [1.19, 1.59], p < 0.001), delirium (OR = 1.15 [1.06, 1.24], p = 0.001), and permanent pacemaker implantation (OR = 1.29 [1.21, 1.37], p < 0.001). In the subgroup analysis of in-hospital mortality, there were no significant differences in any of the observed subgroups (age < 75/75-79/80-84/ ≥ 85a, logistic EuroSCORE < 4/4- < 9/ ≥ 9, gender, NYHA III/IV, previous CABG, peripheral vascular disease, COPD, pulmonary hypertension, renal disease GFR < 30 ml/min, and diabetes mellitus). CONCLUSION In the direct comparison of balloon-expandable and self-expanding TAVR, there are no differences for in-hospital mortality in subgroups.
Collapse
|
40
|
van Wely M, van Nieuwkerk AC, Rooijakkers M, van der Wulp K, Gehlmann H, Verkroost M, van Garsse L, Geuzebroek G, Baz JA, Tchétché D, De Brito FS, Barbanti M, Kornowski R, Latib A, D'Onofrio A, Ribichini F, Dangas G, Mehran R, Delewi R, van Royen N. Transaxillary versus transfemoral access as default access in TAVI: A propensity matched analysis. Int J Cardiol 2024; 394:131353. [PMID: 37696359 DOI: 10.1016/j.ijcard.2023.131353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 08/10/2023] [Accepted: 09/08/2023] [Indexed: 09/13/2023]
Abstract
BACKGROUND Transfemoral (TF) access is default in transcatheter aortic valve implantation (TAVI). Transaxillary (TAx) access has been shown to be a safe alternative in case of prohibitive iliofemoral anatomy, but whether TAx as preferred access has similar safety and efficacy as TF access is unknown. The aim of this study was to compare outcomes between patients treated with self-expanding devices using TF or TAx route as preferred access in TAVI. METHODS A single center cohort of 354 patients treated using TAx as preferred access and a multi-center cohort of 5980 patients treated using TF access were compared. Propensity score matching was used to reduce selection bias and potential confounding. After propensity score matching, each group consisted of 322 patients. Clinical outcomes according to VARC-2 were compared using chi-square test. RESULTS In 6334 patients undergoing TAVI, mean age was 81.4 ± 7.0 years, 57% was female and median logistic EuroSCORE was 14.7% (IQR 9.5-22.6). In the matched population (age 79.3 ± 7.0, 50% female, logistic EuroSCORE 13.4%, IQR 9.0-21.5), primary outcomes 30-day and one-year all-cause mortality were similar between Tax and TF groups (30 days: 5% versus 6%, p = 0.90; 1 year: 20% versus 16%, p = 0.17). Myocardial infarction was more frequent in patients undergoing Tax TAVI compared with TF (4% versus 1%, p = 0.05), but new permanent pacemakers were less frequently implanted (12% versus 21%, p = 0.001). CONCLUSION TAx as preferred access is feasible and safe with outcomes that are comparable to TF access.
Collapse
|
41
|
Boxhammer E, Dienhart C, Kletzer J, Ramsauer S, Kopp K, Prinz E, Wintersteller W, Blessberger H, Hammerer M, Steinwender C, Lichtenauer M, Hoppe UC. Elevated systolic pulmonary artery pressure is a substantial predictor of increased mortality after transcatheter aortic valve replacement in males, not in females. Clin Res Cardiol 2024; 113:138-155. [PMID: 37750991 PMCID: PMC10808322 DOI: 10.1007/s00392-023-02307-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Accepted: 09/05/2023] [Indexed: 09/27/2023]
Abstract
BACKGROUND While pulmonary hypertension (PH) in patients with severe aortic valve stenosis (AS) is associated with increased mortality after transcatheter aortic valve replacement (TAVR), there is limited data on gender differences in the effects on long-term survival. OBJECTIVE The aim of this retrospective, multicenter study was to investigate the prognostic impact of pre-interventional PH on survival of TAVR patients with respect to gender. METHODS 303 patients undergoing TAVR underwent echocardiography to detect PH prior to TAVR via measurement of systolic pulmonary artery pressure (sPAP). Different cut-off values were set for the presence of PH. The primary endpoint was all-cause mortality at 1, 3 and 5 years. RESULTS Kaplan-Meier analysis by gender showed that only males exhibited significant increased mortality at elevated sPAP values during the entire follow-up period of 5 years (sPAP ≥ 40 mmHg: p ≤ 0.001 and sPAP ≥ 50 mmHg: p ≤ 0.001 in 1- to 5-year survival), whereas high sPAP values had no effect on survival in females. In Cox regression analysis based on the selected sPAP thresholds, male gender was an independent risk factor for long-term mortality after TAVR in all time courses. CONCLUSION Male gender was an isolated risk factor for premature death after TAVR in patients with echocardiographic evidence of PH and severe AS. This could mean that, the indication for TAVR should be discussed more critically in men with severe AS and an elevated sPAP, while in females, PH should not be an exclusion criterion for TAVR.
Collapse
|
42
|
Pibarot P. Discordant Low-Gradient Aortic Stenosis: Assessing the Valve and the Myocardium. Tex Heart Inst J 2024; 51:238288. [PMID: 38220578 DOI: 10.14503/thij-23-8288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
|
43
|
Hof A, Wienemann H, Veulemans V, Ludwig S, Rudolph TK, Geißen S, Kuhn E, Eghbalzadeh K, Bleiziffer S, Zeus T, Sedaghat A, Schofer N, Baldus S, Adam M, Mauri V. Feasibility and outcome of third-generation transcatheter aortic valve implantation in patients with extra-large aortic annulus. Clin Res Cardiol 2024; 113:107-115. [PMID: 37524838 PMCID: PMC10808444 DOI: 10.1007/s00392-023-02278-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 07/24/2023] [Indexed: 08/02/2023]
Abstract
BACKGROUND Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.
Collapse
|
44
|
Zidan A, Jain R. Rethinking the Management of Asymptomatic Severe Aortic Valve Stenosis: Embracing Early Intervention for Better Outcomes. Tex Heart Inst J 2024; 51:238295. [PMID: 38212956 DOI: 10.14503/thij-23-8295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
|
45
|
Lazar RM, Myers T, Gropen TI, Leesar MA, Davies J, Gerstenecker A, Norling A, Pavol MA, Marshall RS, Kodali S. Cerebral blood flow and neurocognition in patients undergoing transcatheter aortic valve replacement for severe aortic stenosis. EUROPEAN HEART JOURNAL OPEN 2024; 4:oead124. [PMID: 38174348 PMCID: PMC10763524 DOI: 10.1093/ehjopen/oead124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/30/2023] [Accepted: 11/12/2023] [Indexed: 01/05/2024]
Abstract
Aims Aortic valve stenosis (AS) results in higher systolic pressure to overcome resistance from the stenotic valve, leading to heart failure and decline in cardiac output. There has been no assessment of cerebral blood flow (CBF) association with neurocognition in AS or the effects of valve replacement. The goal was to determine if AS is associated with altered cerebral haemodynamics and impaired neurocognition, and whether transcatheter aortic valve replacement (TAVR) improves haemodynamics and cognition. Methods and results In 42 patients with planned TAVR, transcranial Doppler (TCD) assessed bilateral middle cerebral artery (MCA) mean flow velocities (MFVs); abnormality was <34.45 cm/s. The neurocognitive battery assessed memory, language, attention, visual-spatial skills, and executive function, yielding a composite Z-score. Impairment was <1.5 SDs below the normative mean. The mean age was 78 years, 59% Male, and the mean valve gradient was 46.87 mm/Hg. Mean follow-up was 36 days post-TAVR (range 27-55). Pre-TAVR, the mean MFV was 42.36 cm/s (SD = 10.17), and the mean cognitive Z-score was -0.22 SDs (range -1.99 to 1.08) below the normative mean. Among the 34 patients who returned after TAVR, the MFV was 41.59 cm/s (SD = 10.42), not different from baseline (P = 0.66, 2.28-3.67). Post-TAVR, average Z-scores were 0.17 SDs above the normative mean, not meeting the pre-specified threshold for a clinically significant 0.5 SD change. Conclusion Among patients with severe AS, there was little impairment of MFV on TCD and no correlation with cognition. Transcatheter aortic valve replacement did not affect MFV or cognition. Assumptions about diminished CBF and improvement after TAVR were not supported.
Collapse
|
46
|
Cour A, Burel J, Garnier M, Durand E, Demeyere M, Dacher JN. CT annulus sizing prior to transcatheter aortic valve replacement (TAVR): evaluation of free-breathing versus breath-holding acquisition. Eur Radiol 2023; 33:8521-8527. [PMID: 37470824 DOI: 10.1007/s00330-023-09913-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/07/2023] [Accepted: 05/14/2023] [Indexed: 07/21/2023]
Abstract
OBJECTIVES To assess feasibility and accuracy of aortic annulus measurements using cardiac computed tomography angiography (CTA) performed during free-breathing prior to transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS Sixty consecutive TAVR candidates underwent free-breathing wide-detector cardiac CTA, followed by a percutaneous valve replacement. For each, a theoretical valve size was suggested through CT measurements of the annulus, then compared to the size of the actual implanted transcatheter heart valve (THV). The procedural success and the 30-day outcomes were collected. Image quality of the annulus was also studied according to subjective and objective criteria. Data of a control group of 60 patients previously evaluated on breath-holding were also evaluated. RESULTS A total of 120 patients (mean age, 83 years ± 7, 60 men) were evaluated. All CT acquisitions provided sufficient image quality allowing precise annulus measurements. Mean attenuation (p < 0.001) and image noise (p = 0.01) were higher in the free-breathing group, while image quality was comparable (p = 0.36). The agreement rate between CT-suggested valve size and THV implanted size was comparable, estimated at 87% (κ = 0.79, 95%CI 0.566, 0.908) on free-breathing vs. 82% (κ = 0.78, 95%CI 0.634, 0.904) on breath-holding. The procedure was successful for all patients without increase in 30-day mortality or adverse events. CONCLUSIONS Free-breathing cardiac CTA allows accurate aortic annulus measurements without compromising image quality or patients' outcome after TAVR. Elderly patients experiencing dyspnea, discomfort, or hearing loss that could prevent proper breath-holding should not be excluded from CT prior to TAVR. CLINICAL RELEVANCE STATEMENT To decrease elderly patients' discomfort, MDCT evaluation prior to transcatheter aortic valve replacement (TAVR) may be performed on quiet breathing with no significant impact on the outcome. KEY POINTS • Adhering to CT breathing commands can be challenging for patients with dyspnea, hearing impairment, agitation, or pulmonary diseases. • Free-breathing cardiac CT may be an alternative to breath-holding for patients unable to follow the breathing commands. • Wide-detector CT acquisition on free-breathing does not impair annulus measurements and prosthesis sizing in patients scheduled for TAVR.
Collapse
|
47
|
van Nieuwkerk AC, Hemelrijk KI, Bron EE, Leeuwis AE, Majoie CBLM, Daemen MJAP, Moonen JEF, de Sitter A, Bouma BJ, van der Flier WM, Baan J, Piek JJ, Biessels GJ, Delewi R. Cardiac output, cerebral blood flow and cognition in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation: design and rationale of the CAPITA study. Neth Heart J 2023; 31:461-470. [PMID: 37910335 PMCID: PMC10667193 DOI: 10.1007/s12471-023-01826-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2023] [Indexed: 11/03/2023] Open
Abstract
BACKGROUND Approximately one-third of patients with symptomatic severe aortic valve stenosis who are scheduled for transcatheter aortic valve implantation (TAVI) have some degree of cognitive impairment. TAVI may have negative cognitive effects due to periprocedural micro-emboli inducing cerebral infarction. On the contrary, TAVI may also have positive cognitive effects due to increases in cardiac output and cerebral blood flow (CBF). However, studies that systematically assess these effects are scarce. Therefore, the main aim of this study is to assess cerebral and cognitive outcomes in patients with severe aortic valve stenosis undergoing TAVI. STUDY DESIGN In the prospective CAPITA (CArdiac OutPut, Cerebral Blood Flow and Cognition In Patients With Severe Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Implantation) study, cerebral and cognitive outcomes are assessed in patients undergoing TAVI. One day before and 3 months after TAVI, patients will undergo echocardiography (cardiac output, valve function), brain magnetic resonance imaging (CBF, structural lesions) and extensive neuropsychological assessment. To assess longer-term effects of TAVI, patients will again undergo echocardiography and neuropsychological assessment 1 year after the procedure. The co-primary outcome measures are change in CBF (in ml/100 g per min) and change in global cognitive functioning (Z-score) between baseline and 3‑month follow-up. Secondary objectives include change in cardiac output, white matter hyperintensities and other structural brain lesions. (ClinicalTrials.gov identifier NCT05481008) CONCLUSION : The CAPITA study is the first study designed to systematically assess positive and negative cerebral and cognitive outcomes after TAVI. We hypothesise that TAVI improves cardiac output, CBF and cognitive functioning.
Collapse
|
48
|
Keller LS, Nuche J, Avvedimento M, Real C, Farjat-Pasos J, Paradis JM, DeLarochellière R, Poulin A, Kalavrouziotis D, Dumont E, Galhardo A, Mengi S, Mohammadi S, Rodés-Cabau J. Angina in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2023; 76:991-1002. [PMID: 37137426 DOI: 10.1016/j.rec.2023.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Accepted: 04/03/2023] [Indexed: 05/05/2023]
Abstract
INTRODUCTION AND OBJECTIVES To evaluate the prevalence, clinical characteristics, and outcomes of patients with angina undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. METHODS A total of 1687 consecutive patients with severe aortic stenosis undergoing TAVR at our center were included and classified according to patient-reported angina symptoms prior to the TAVR procedure. Baseline, procedural and follow-up data were collected in a dedicated database. RESULTS A total of 497 patients (29%) had angina prior to the TAVR procedure. Patients with angina at baseline showed a worse New York Heart Association (NYHA) functional class (NYHA class> II: 69% vs 63%; P=.017), a higher rate of coronary artery disease (74% vs 56%; P <.001), and a lower rate of complete revascularization (70% vs 79%; P <.001). Angina at baseline had no impact on all-cause mortality (HR, 1.02; 95%CI, 0.71-1.48; P=.898) and cardiovascular mortality (HR, 1.2; 95%CI, 0.69-2.11; P=.517) at 1 year. However, persistent angina at 30 days post-TAVR was associated with increased all-cause mortality (HR, 4.86; 95%CI, 1.71-13.8; P=.003) and cardiovascular mortality (HR, 20.7; 95%CI, 3.50-122.6; P=.001) at 1-year follow-up. CONCLUSIONS More than one-fourth of patients with severe aortic stenosis undergoing TAVR had angina prior to the procedure. Angina at baseline did not appear to be a sign of a more advanced valvular disease and had no prognostic impact; however, persistent angina at 30 days post-TAVR was associated with worse clinical outcomes.
Collapse
|
49
|
Park S, Kang DY, Ahn JM, Kim DH, Park DW, Park SJ, Kang JW, Yang DH, Lee SA, Koo HJ. Impact of new-onset arrhythmia on cardiac reverse remodeling following transcatheter aortic valve replacement: computed tomography-derived left ventricular and atrial strains. Eur Radiol 2023; 33:8454-8463. [PMID: 37368107 DOI: 10.1007/s00330-023-09836-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 03/03/2023] [Accepted: 04/10/2023] [Indexed: 06/28/2023]
Abstract
OBJECTIVE Patients who undergo transcatheter aortic valve replacement (TAVR) are at risk for new-onset arrhythmia (NOA) that may require permanent pacemaker (PPM) implantation, resulting in decreased cardiac function. We aimed to investigate the factors that are associated with NOA after TAVR and to compare pre- and post-TAVR cardiac functions between patients with and without NOA using CT-derived strain analyses. METHODS We included consecutive patients who underwent pre- and post-TAVR cardiac CT scans six months after TAVR. New-onset left bundle branch block, atrioventricular block, and atrial fibrillation/flutter lasting over 30 days after the procedure and/or the need for PPM diagnosed within 1 year after TAVR were regarded as NOA. Implant depth and left heart function and strains were analyzed using multi-phase CT images and compared between patients with and without NOA. RESULTS Of 211 patients (41.7% men; median 81 years), 52 (24.6%) presented with NOA after TAVR, and 24 (11.4%) implanted PPM. Implant depth was significantly deeper in the NOA group than in the non-NOA group (- 6.7 ± 2.4 vs. - 5.6 ± 2.6 mm; p = 0.009). Left ventricular global longitudinal strain (LV GLS) and left atrial (LA) reservoir strain were significantly improved only in the non-NOA group (LV GLS, - 15.5 ± 4.0 to - 17.3 ± 2.9%; p < 0.001; LA reservoir strain, 22.3 ± 8.9 to 26.5 ± 7.6%; p < 0.001). The mean percent change of the LV GLS and LA reservoir strains was evident in the non-NOA group (p = 0.019 and p = 0.035, respectively). CONCLUSIONS A quarter of patients presented with NOA after TAVR. Deep implant depth on post-TAVR CT scans was associated with NOA. Patients with NOA after TAVR had impaired LV reserve remodeling assessed by CT-derived strains. CLINICAL RELEVANCE STATEMENT New-onset arrhythmia (NOA) following transcatheter aortic valve replacement (TAVR) impairs cardiac reverse remodeling. CT-derived strain analysis reveals that patients with NOA do not show improvement in left heart function and strains, highlighting the importance of managing NOA for optimal outcomes. KEY POINTS • New-onset arrhythmia following transcatheter aortic valve replacement (TAVR) is a concern that interferes with cardiac reverse remodeling. • Comparison of pre-and post-TAVR CT-derived left heart strain provides insight into the impaired cardiac reverse remodeling in patients with new-onset arrhythmia following TAVR. • The expected reverse remodeling was not observed in patients with new-onset arrhythmia following TAVR, given that CT-derived left heart function and strains did not improve.
Collapse
|
50
|
Langenbach IL, Langenbach MC, Mayrhofer T, Foldyna B, Maintz D, Klein K, Wienemann H, Krug KB, Hellmich M, Adam M, Naehle CP. Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: a prospective clinical trial. Eur Radiol 2023:10.1007/s00330-023-10403-x. [PMID: 37979008 DOI: 10.1007/s00330-023-10403-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/25/2023] [Accepted: 09/17/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION This study investigated the use of dual-energy spectral detector computed tomography (CT) and virtual monoenergetic imaging (VMI) reconstructions in pre-interventional transcatheter aortic valve replacement (TAVR) planning. We aimed to determine the minimum required contrast medium (CM) amount to maintain diagnostic CT imaging quality for TAVR planning. METHODS In this prospective clinical trial, TAVR candidates received a standardized dual-layer spectral detector CT protocol. The CM amount (Iohexol 350 mg iodine/mL, standardized flow rate 3 mL/s) was reduced systematically after 15 patients by 10 mL, starting at 60 mL (institutional standard). We evaluated standard, and 40- and 60-keV VMI reconstructions. For image quality, we measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and diameters in multiple vessel sections (i.e., aortic annulus: diameter, perimeter, area; aorta/arteries: minimal diameter). Mixed regression models (MRM), including interaction terms and clinical characteristics, were used for comparison. RESULTS Sixty consecutive patients (mean age, 79.4 ± 7.5 years; 28 females, 46.7%) were included. In pre-TAVR CT, the CM reduction to 40 mL is possible without affecting the image quality (MRM: SNR: -1.1, p = 0.726; CNR: 0.0, p = 0.999). VMI 40-keV reconstructions showed better results than standard reconstructions with significantly higher SNR (+ 6.04, p < 0.001). Reduction to 30 mL CM resulted in a significant loss of quality (MRM: SNR: -12.9, p < 0.001; CNR: -13.9, p < 0.001), regardless of the reconstruction. Across the reconstructions, we observed no differences in the metric evaluation (p > 0.914). CONCLUSION Among TAVR candidates undergoing pre-interventional CT at a dual-layer spectral detector system, applying 40 mL CM is sufficient to maintain diagnostic image quality. VMI 40-keV reconstructions improve the vessel attenuation and are recommended for evaluation. CLINICAL RELEVANCE STATEMENT Contrast medium reduction to 40 mL in pre-interventional transcatheter aortic valve replacement CT using dual-energy CT maintains image quality, while 40-keV virtual monoenergetic imaging reconstructions enhance vessel attenuation. These results offer valuable recommendations for interventional transcatheter aortic valve replacement evaluation and potentially improve nephroprotection in patients with compromised renal function. KEY POINTS • Patients undergoing transcatheter aortic valve replacement (TAVR), requiring pre-interventional CT, are often multimorbid with impaired renal function. • Using a spectral detector dual-layer CT, contrast medium reduction to 40 mL is feasible, maintaining diagnostic image quality. • The additional application of virtual monoenergetic image reconstructions with 40 keV improves vessel attenuation significantly in clinical practice.
Collapse
|