26
|
The Influence of Static Load and Sideways Impact Fall on Extramedullary Bone Plates Used to Treat Intertrochanteric Femoral Fracture: A Preclinical Strength Assessment. Ann Biomed Eng 2022; 50:1923-1940. [PMID: 35821164 DOI: 10.1007/s10439-022-03013-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 07/06/2022] [Indexed: 12/30/2022]
Abstract
Hip fracture accounts for a large number of hospitalizations, thereby causing substantial economic burden. Majority (> 90%) of all hip fractures are associated to sideways fall. Studies on sideways fall usually involve loading at quasi-static or at constant displacement rate, which neglects the physics of actual fall. Understanding femur resonance frequency and associated mode shapes excited by dynamic loads is also critical. Two commercial extramedullary implants, proximal femoral locking plate (PFLP) and variable angle dynamic hip screw (VA-DHS), were chosen to carry out the preclinical assessments on a simulated Evans-I type intertrochanteric fracture. In this study, we hypothesized that the behavior of the implant depends on the loading types-axial static and transverse impact-and a rigid implanted construct will absorb less impact energy for sideways fall. The in silico models were validated using experimental measurements of full-field strain data obtained from a 2D digital image correlation (DIC) study. Under peak axial load of 3 kN, PFLP construct predicted greater axial stiffness (1.07 kN/mm) as opposed to VA-DHS (0.85 kN/mm), although the former predicted slightly higher proximal stress shielding. Further, with greater mode 2 frequency, PFLP predicted improved performance in resisting bending due to sideways fall as compared to the other implant. Overall, the PFLP implanted femur predicted the least propensity to adverse stress intensities, suggesting better structural rigidity and higher capacity in protecting the fractured femur against fall.
Collapse
|
27
|
Donaldson K, Thomas J, Zhu Y, Clark-Deener S, Alperin M, De Vita R. In-plane and out-of-plane deformations of gilt utero-sacral ligaments. J Mech Behav Biomed Mater 2022; 131:105249. [PMID: 35526346 DOI: 10.1016/j.jmbbm.2022.105249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 04/07/2022] [Accepted: 04/17/2022] [Indexed: 11/27/2022]
Abstract
The uterosacral ligaments (USLs) are supportive structures of the uterus and apical vagina. The mechanical function of these ligaments within the pelvic floor is crucial not only in normal physiological conditions but also in reconstructive surgeries for pelvic organ prolapse. Discrepancies in their anatomical and histological description exist in the literature, but such discrepancies are likely due to large variations of these structures. This makes mechanical testing very challenging, requiring the development of advanced methods for characterizing their mechanical properties. This study proposes the use of planar biaxial testing, digital image correlation (DIC), and optical coherence tomography (OCT) to quantify the deformations of the USLs, both in-plane and out-of-plane. Using the gilts as an animal model, the USLs were found to deform significantly less in their main direction (MD) of in vivo loading than in the direction perpendicular to it (PD) at increasing equibiaxial stresses. Under constant equibiaxial loading, the USLs deform over time equally, at comparable rates in both the MD and PD. The thickness of the USLs decreases as the equibiaxial loading increases but, under constant equibiaxial loading, the thickness increases in some specimens and decreases in others. These findings could contribute to the design of new mesh materials that augment the support function of USLs as well as noninvasive diagnostic tools for evaluating the integrity of the USLs.
Collapse
|
28
|
Moeini M, Ménard AL, Yue L, Hajizadeh M, Begon M, Lévesque M. Computationally efficient model to predict the deformations of a cellular foot orthotic. Comput Biol Med 2022; 146:105532. [PMID: 35751191 DOI: 10.1016/j.compbiomed.2022.105532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 03/19/2022] [Accepted: 04/13/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND Foot orthotics (FOs) are frequently prescribed to provide comfortable walking for patients. Finite element (FE) simulation and 3D printing pave the way to analyse, optimize and fabricate functionally graded lattice FOs where the local stiffness can vary to meet the therapeutic needs of each individual patient. Explicit FE modelling of lattice FOs with converged 3D solid elements is computationally prohibitive. This paper presents a more computationally efficient FE model of cellular FOs. METHOD The presented FE model features shell elements whose mechanical properties were computed from the numerical homogenization technique. To verify the results, the predictions of the homogenized models were compared to the explicit model's predictions when the FO was under a static pressure distribution of a foot. To validate the results, the predictions were also compared with experimental measurements when the FO was under a vertical displacement at the medial longitudinal arch. RESULTS The verification procedure showed that the homogenized model was 46 times faster than the explicit model, while their relative difference was less than 8% to predict the local minimum of out-of-plane displacement. The validation procedure showed that both models predicted the same contact force with a relative difference of less than 1%. The predicted force-displacement curves were also within a 90% confidence interval of the experimental measurements having a relative difference smaller than 10%. In this case, using the homogenized model reduced the computational time from 22 h to 22 min. CONCLUSION The presented homogenized model can be therefore employed to speed up the FE simulation to predict the deformations of the cellular FOs.
Collapse
|
29
|
Mariano CA, Sattari S, Quiros KAM, Nelson TM, Eskandari M. Examining lung mechanical strains as influenced by breathing volumes and rates using experimental digital image correlation. Respir Res 2022; 23:92. [PMID: 35410291 PMCID: PMC8999998 DOI: 10.1186/s12931-022-01999-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 03/18/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Mechanical ventilation is often employed to facilitate breathing in patients suffering from respiratory illnesses and disabilities. Despite the benefits, there are risks associated with ventilator-induced lung injuries and death, driving investigations for alternative ventilation techniques to improve mechanical ventilation, such as multi-oscillatory and high-frequency ventilation; however, few studies have evaluated fundamental lung mechanical local deformations under variable loading. METHODS Porcine whole lung samples were analyzed using a novel application of digital image correlation interfaced with an electromechanical ventilation system to associate the local behavior to the global volume and pressure loading in response to various inflation volumes and breathing rates. Strains, anisotropy, tissue compliance, and the evolutionary response of the inflating lung were analyzed. RESULTS Experiments demonstrated a direct and near one-to-one linear relationship between applied lung volumes and resulting local mean strain, and a nonlinear relationship between lung pressures and strains. As the applied air delivery volume was doubled, the tissue surface mean strains approximately increased from 20 to 40%, and average maximum strains measured 70-110%. The tissue strain anisotropic ratio ranged from 0.81 to 0.86 and decreased with greater inflation volumes. Local tissue compliance during the inflation cycle, associating evolutionary strains in response to inflation pressures, was also quantified. CONCLUSION Ventilation frequencies were not found to influence the local stretch response. Strain measures significantly increased and the anisotropic ratio decreased between the smallest and greatest tidal volumes. Tissue compliance did not exhibit a unifying trend. The insights provided by the real-time continuous measures, and the kinetics to kinematics pulmonary linkage established by this study offers valuable characterizations for computational models and establishes a framework for future studies to compare healthy and diseased lung mechanics to further consider alternatives for effective ventilation strategies.
Collapse
|
30
|
Mylo MD, Hofmann M, Balle F, Beisel S, Speck T, Speck O. Biomechanics of the parasite-host interaction of the European mistletoe. JOURNAL OF EXPERIMENTAL BOTANY 2022; 73:1204-1221. [PMID: 34849736 PMCID: PMC8866656 DOI: 10.1093/jxb/erab518] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 11/24/2021] [Indexed: 05/09/2023]
Abstract
The European mistletoe (Viscum album) is an epiphytic hemiparasite that attaches to its host by an endophytic system. Two aspects are essential for its survival: the structural integrity of the host-parasite interface must be maintained during host growth and the functional integrity of the interface must be maintained during ontogeny and under mechanical stress. We investigated the mechanical properties of the mistletoe-host interaction. Intact and sliced mistletoe-host samples, with host wood as reference, were subjected to tensile tests up to failure. We quantified the rough fractured surface by digital microscopy and analysed local surface strains by digital image correlation. Tensile strength and deformation energy were independent of mistletoe age but exhibited markedly lower values than host wood samples. Cracks initiated at sites with a major strain of about 30%, especially along the mistletoe-host interface. The risk of sudden failure was counteracted by various sinkers and a lignification gradient that smooths the differences in the mechanical properties between the two species. Our results improve the understanding of the key mechanical characteristics of the host-mistletoe interface and show that the mechanical connection between the mistletoe and its host is age-independent. Thus, functional and structural integrity is ensured over the lifetime of the mistletoe.
Collapse
|
31
|
Elouneg A, Bertin A, Lucot Q, Tissot V, Jacquet E, Chambert J, Lejeune A. In vivo skin anisotropy dataset from annular suction test. Data Brief 2022; 40:107835. [PMID: 35106340 PMCID: PMC8784637 DOI: 10.1016/j.dib.2022.107835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 01/08/2022] [Accepted: 01/12/2022] [Indexed: 12/05/2022] Open
Abstract
To characterize the anisotropic and viscoelastic behaviors of the skin, we conducted an experimental campaign of in-vivo suction tests using the CutiScan®CS100 device from Courage and Khazaka electronics. In this data paper, we present the raw acquired data of the tests and their respective treated data. The tests were performed 30 times on the anterior forearm of a 28-year-old Caucasian male at different pressure set-points, ranging from 100 to 500 mbar with an increment of 20 mbar, at ambient temperature in a windowless room. The primary dataset consists of videos recorded by a probe camera associated with the CutiScan® device during the tests. After data treatment with DIC (Digital Image Correlation) technique and based on a homemade Python program, we have obtained secondary data tables and 2D displacement for all mapped grid nodes.
Collapse
|
32
|
Gologorsky CJ, Middendorf JM, Cohen I, Bonassar LJ. Depth-dependent patterns in shear modulus of temporomandibular joint cartilage correspond to tissue structure and anatomic location. J Biomech 2021; 129:110815. [PMID: 34706301 DOI: 10.1016/j.jbiomech.2021.110815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 10/07/2021] [Accepted: 10/08/2021] [Indexed: 11/17/2022]
Abstract
To fully understand TMJ cartilage degeneration and appropriate repair mechanisms, it is critical to understand the native structure-mechanics relationships of TMJ cartilage and any local variation that may occur in the tissue. Here, we used confocal elastography and digital image correlation to measure the depth-dependent shear properties as well as the structural properties of TMJ cartilage at different anatomic locations on the condyle to identify depth-dependent changes in shear mechanics and structure. We found that samples at every anatomic location showed qualitatively similar shear modulus profiles as a function of depth. In every sample, four distinct zones of mechanical behavior were observed, with shear modulus values spanning 3-5 orders of magnitude across zones. However, quantitative characteristics of shear modulus profiles varied by anatomic location, particularly zone size and location, with the most significant variation in zonal width occurring in the fibrocartilage surface layer (zone 1). This anatomic variation suggests that different locations on the TMJ condyle may play unique mechanical roles in TMJ function. Furthermore, zones identified in the mechanical data corresponded on a sample-by-sample basis to zones identified in the structural data, indicating the known structural zones of TMJ cartilage may also play unique mechanical roles in TMJ function.
Collapse
|
33
|
Palanca M, Liebsch C, Hübner S, Marras D, Ruspi ML, Marconi F, Cristofolini L, Wilke HJ. Global and local characterization explains the different mechanisms of failure of the human ribs. J Mech Behav Biomed Mater 2021; 125:104931. [PMID: 34736031 DOI: 10.1016/j.jmbbm.2021.104931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/03/2021] [Accepted: 10/25/2021] [Indexed: 10/20/2022]
Abstract
Knowledge of the mechanics and mechanistic reasons inducing rib fracture is fundamental for forensic investigations and for the design of implants and cardiopulmonary resuscitation devices. A mechanical rationale to explain the different rib mechanisms of failure is still a challenge. The aim of this work was to experimentally characterize human ribs to test the hypothesis that a correlation exists between the ribs properties and the mechanism of failure. 89 ribs were tested in antero-posterior compression. The full-field strain distribution was measured through Digital Image Correlation. The fracture load ranged 7-132 N. Two main different mechanisms of failure were observed: brittle and buckling. The strain analysis showed that the direction of principal strains was either aligned with the ribs, or oblique, around 45°, with a rather uniform direction in the most strained area. The maximum principal strains were in the range between 1000 and 30000 microstrain and the minimum principal strain between -30000 and -800 microstrain. The ribs undergoing brittle fracture had significantly thicker cortical bone than those undergoing buckling. Also, larger tensile strains were observed in the specimens with brittle fracture than in the buckling ones. These findings support the focus of cortical thickness modelling which could help in sharpening computational models for the aforesaid purposes.
Collapse
|
34
|
Palanca M, Barbanti-Bròdano G, Marras D, Marciante M, Serra M, Gasbarrini A, Dall'Ara E, Cristofolini L. Type, size, and position of metastatic lesions explain the deformation of the vertebrae under complex loading conditions. Bone 2021; 151:116028. [PMID: 34087385 DOI: 10.1016/j.bone.2021.116028] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 05/14/2021] [Accepted: 05/29/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Bone metastases may lead to spine instability and increase the risk of fracture. Scoring systems are available to assess critical metastases, but they lack specificity, and provide uncertain indications over a wide range, where most cases fall. The aim of this work was to use a novel biomechanical approach to evaluate the effect of lesion type, size, and location on the deformation of the metastatic vertebra. METHOD Vertebrae with metastases were identified from 16 human spines from a donation programme. The size and position of the metastases, and the Spine Instability Neoplastic Score (SINS) were evaluated from clinical Quantitative Computed Tomography images. Thirty-five spine segments consisting of metastatic vertebrae and adjacent healthy controls were biomechanically tested in four different loading conditions. The strain distribution over the entire vertebral bodies was measured with Digital Image Correlation. Correlations between the features of the metastasis (type, size, position and SINS) and the deformation of the metastatic vertebrae were statistically explored. RESULTS The metastatic type (lytic, blastic, mixed) characterizes the vertebral behaviour (Kruskal-Wallis, p = 0.04). In fact, the lytic metastases showed more critical deformation compared to the control vertebrae (average: 2-fold increase, with peaks of 14-fold increase). By contrast, the vertebrae with mixed or blastic metastases did not show a clear trend, with deformations similar or lower than the controls. Once the position of the lytic lesion with respect to the loading direction was taken into account, the size of the lesion was significantly correlated with the perturbation to the strain distribution (r2 = 0.72, p < 0.001). Conversely, the SINS poorly correlated with the mechanical evidence, and only in case of lytic lesions (r2 = 0.25, p < 0.0001). CONCLUSION These results highlight the relevance of the size and location of the lytic lesion, which are marginally considered in the current clinical scoring systems, in driving the spinal biomechanical instability. The strong correlation with the biomechanical evidence indicates that these parameters are representative of the mechanical competence of the vertebra. The improved explanatory power compared to the SINS suggests including them in future guidelines for the clinical practice.
Collapse
|
35
|
Dagro AM, Li H, DiLeonardi AM, Hogan JD. Nonlinearity of the coefficient of thermal expansion in brain tissue. J Mech Behav Biomed Mater 2021; 123:104779. [PMID: 34425349 DOI: 10.1016/j.jmbbm.2021.104779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 07/28/2021] [Accepted: 08/10/2021] [Indexed: 11/30/2022]
Abstract
The coefficient of thermal expansion (CTE) in biological tissues is an integral parameter behind the application of electromagnetic energy to biomedical technologies; however, its behavior is far from being fully characterized. In this study, we apply digital image correlation (DIC) to non-invasively measure the microscale thermal expansions of recently excised embryonic E18 rodent brain tissue slices. Although the CTE has been measured previously in soft tissues, the literature surrounding the expansion of brain tissue remains sparse. Previous work in measuring the thermal expansion behavior of soft tissue often simplifies the results into a single measurement of a linear CTE parameter and fails to convey the temperature-dependent nonlinearity that exists. In this work, we demonstrate that: (1) the coefficient of brain tissue is more similar to fat than blood, and (2) there exists a significant nonlinear increase in CTE at physiologically-relevant temperatures. This suggests some limitations with the interpretation of previously reported values of the CTE, which are often measured at room temperature.
Collapse
|
36
|
Meng X, Qin Q, Qu C. Tensile and compressive strain evolutions of bovine compact bone under four-point bending fatigue loading. J Mech Behav Biomed Mater 2021; 123:104774. [PMID: 34404024 DOI: 10.1016/j.jmbbm.2021.104774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 04/08/2021] [Accepted: 08/10/2021] [Indexed: 11/25/2022]
Abstract
Bones are biological composite materials with multiscale structures. Bone fatigue damage is commonly characterized by an increase in strain that is accompanied by microdamage at different scales. This study investigated the damage evolutions of bone specimens under four-point bending fatigue loading using neutral axis migration. Tensile and compressive strains during the fatigue process were simultaneously measured using a digital image correlation technique. The compressive strain of the bone specimen increased rapidly at first and then proceeded slowly while the tensile strain decreased during fatigue loading. Consequently, the neutral axis shifted downward as the damage accumulated. A positive correlation exists between the downward offset of the neutral axis and the number of cycles. The variation in compressive strain is larger than that in tensile strain in this situation.
Collapse
|
37
|
McGuire JA, Monclova JL, Coariti ACS, Stine CA, Toussaint KC, Munson JM, Dillard DA, De Vita R. Tear propagation in vaginal tissue under inflation. Acta Biomater 2021; 127:193-204. [PMID: 33831574 DOI: 10.1016/j.actbio.2021.03.065] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 03/06/2021] [Accepted: 03/30/2021] [Indexed: 12/21/2022]
Abstract
Vaginal tearing at childbirth is extremely common yet understudied despite the long-term serious consequences on women's health. The mechanisms of vaginal tearing remain unknown, and their knowledge could lead to the development of transformative prevention and treatment techniques for maternal injury. In this study, whole rat vaginas with pre-imposed elliptical tears oriented along the axial direction of the organs were pressurized using a custom-built inflation setup, producing large tear propagation. Large deformations of tears through propagation were analyzed, and nonlinear strains around tears were calculated using the digital image correlation technique. Second harmonic generation microscopy was used to examine collagen fiber organization in mechanically untested and tested vaginal specimens. Tears became increasingly circular under pressure, propagating slowly up to the maximum pressure and then more rapidly. Hoop strains were significantly larger than axial strains and displayed a region- and orientation-dependent response with tear propagation. Imaging revealed initially disorganized collagen fibers that aligned along the axial direction with increasing pressure. Fibers in the near-regions of tear tips aligned toward the hoop direction, hampering tear propagation. Changes in tear geometry, regional strains, and fiber orientation revealed the inherent toughening mechanisms of the vaginal tissue. STATEMENT OF SIGNIFICANCE: Women's reproductive health has historically been understudied despite alarming maternal injury and mortality rates in the world. Maternal injury and disability can be reduced by advancing our limited understanding of the large deformations experienced by women's reproductive organs. This manuscript presents, for the first time, the mechanics of tear propagation in vaginal tissue and changes to the underlying collagen microstructure near to and far from the tear. A novel inflation setup capable of maintaining the in vivo tubular geometry of the vagina while propagating a pre-imposed tear was developed. Toughening mechanisms of the vagina to propagation were examined through measurements of tear geometry, strain distributions, and reorientation of collagen fibers. This research draws from current advances in the engineering science and mechanics fields with the goal of improving maternal health care.
Collapse
|
38
|
Prajapati A, Morse S, Chirazi A, Burnett T, Withers PJ. Complementary time-lapse datasets of x-ray computed tomography and real-time strain mapping for an ex-situ study of non-crimp glass fibre composites under fatigue loading. Data Brief 2021; 37:107157. [PMID: 34095394 PMCID: PMC8167186 DOI: 10.1016/j.dib.2021.107157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 04/29/2021] [Accepted: 05/12/2021] [Indexed: 11/11/2022] Open
Abstract
Data published in this paper corresponds to a time-lapse ex-situ experiment aimed at analyzing the tension-tension fatigue damage in non-crimp glass-epoxy composites by multi-scale x-ray computed tomography (XCT) of the damage features and their timeline. This is then correlated with the strain fields obtained through digital image correlation (DIC). The XCT - DIC datasets by is acquired by interrupting mechanical fatigue tests at three time-steps, after the material has undergone 0 cycles, 70,000 cycles, 80,000 cycles, and 120,000 cycles. This is one of the first multi-modally correlated datasets available for these types of non-crimp glass fibre composites, which explore the structure-property relationship in a time-dependent behavior. This dataset can be used to explore glass-fibre composites microstructure under a progressive damage scheme and can be used to test and train a plethora of image processing and analysis techniques. This dataset can also be used as an attempt to model the fatigue behavior of quasi-unidirectional non-crimp fibre composites by image-based simulations.
Collapse
|
39
|
Kok J, Grassi L, Gustafsson A, Isaksson H. Femoral strength and strains in sideways fall: Validation of finite element models against bilateral strain measurements. J Biomech 2021; 122:110445. [PMID: 33933857 DOI: 10.1016/j.jbiomech.2021.110445] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 02/15/2021] [Accepted: 04/12/2021] [Indexed: 11/29/2022]
Abstract
Low impact falls to the side are the main cause of hip fractures in elderly. Finite element (FE) models of the proximal femur may help in the assessment of patients at high risk for a hip fracture. However, extensive validation is essential before these models can be used in a clinical setting. This study aims to use strain measurements from bilateral digital image correlation to validate an FE model against ex vivo experimental data of proximal femora under a sideways fall loading condition. For twelve subjects, full-field strain measurements were available on the medial and lateral side of the femoral neck. In this study, subject-specific FE models were generated based on a consolidated procedure previously validated for stance loading. The material description included strain rate dependency and separate yield and fracture strain limits in tension and compression. FE predicted fracture force and experimentally measured peak forces showed a strong correlation (R2 = 0.92). The FE simulations predicted the fracture initiation within 3 mm distance of the experimental fracture line for 8/12 subjects. The predicted and measured strains correlated well on both the medial side (R2 = 0.87) and the lateral side (R2 = 0.74). The lower correlation on the lateral side is attributed to the irregularity of the cortex and presence of vessel holes in this region. The combined validation against bilateral full-field strain measurements and peak forces has opened the door for a more elaborate qualitative and quantitative validation of FE models of femora under sideways fall loading.
Collapse
|
40
|
Schmidt A, Kididane I, Schlenz MA, Wöstmann B, Kolling S, Schrader P. Finite element simulation of fixed dental prostheses made from PMMA -Part I: Experimental investigation under quasi-static loading and chewing velocities. Dent Mater J 2021; 40:704-711. [PMID: 33612565 DOI: 10.4012/dmj.2020-230] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Material properties are of high clinical relevance, even though in vitro laboratory setups may differ from clinical conditions. Therefore, the aim of the present study was to investigate the fracture behavior of three-unit bridge restoration (Telio CAD) with different test velocities (1.0 mm/min International Organization for Standardization (ISO) standard speed/ 130 mm/s mean chewing velocity) and to provide crucial validation experiments for the upcoming Part 2 of our study, in which FEA on such temporary restorations will be conducted. Local strains were detected using digital image correlation (DIC). The material exhibited significantly different responses at different test velocities, and the forces at fracture were found to be much smaller at chewing velocity (130 mm/s) than in the quasi-static test. Overall, the results of the present study show that characteristics pertaining to material behavior can change significantly with increasing chewing velocity, and that fracture forces decrease with increasing test velocity.
Collapse
|
41
|
Yoon S, Jung HJ, Knowles JC, Lee HH. Digital image correlation in dental materials and related research: A review. Dent Mater 2021; 37:758-771. [PMID: 33715864 DOI: 10.1016/j.dental.2021.02.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 02/23/2021] [Accepted: 02/24/2021] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Digital image correlation (DIC) is a non-contact image processing technique for full-field strain measurement. Although DIC has been widely used in engineering and biomechanical fields, it is in the spotlight only recently in dental materials. Therefore, the purpose of this review paper is introducing the working principle of the DIC technique with some modifications and providing further potential applications in various dental materials and related fields. METHODS The accuracy of the algorithm depending on the environmental characteristics of the DIC technique, as well as the advantages and disadvantages of strain measurement using optical measurements, have been elaborated in dental materials and related fields. Applications to those researches have been classified into the following categories: shrinkage behavior of light-cured resin composite, resin-tooth interface, mechanical properties of tooth structure, crack extension and elastic properties of dental materials, and deformation of dental restoration and prosthesis. This classification and discussion were performed using literature survey and review based on numerous papers in the international journals published over the past 20 years. The future directions for predicting the precise deformation of dental materials under various environments, as well as limitations of the DIC technique, was presented in this review. RESULTS The DIC technique was demonstrated as a more effective tool to measure full-field polymerization shrinkage of composite resin, even in a simulated clinical condition over the existing methods. Moreover, the DIC combined with other technologies can be useful to evaluate the mechanical behavior of material-tooth interface, dentine structure and restorative and prosthetic materials with high accuracy. Three-dimensional DIC using two cameras extended the measurement range in-plane to out-of-plane, enabling measure of the strain directly on the surface of dental restorations or prosthesis. SIGNIFICANCE DIC technique is a potential tool for measuring and predicting the full-field deformation/strain of dental materials and actual prostheses in diverse clinical conditions. The versatility of DIC can replace the existing complex sensor devices in those studies.
Collapse
|
42
|
Sánchez E, Schilling C, Grupp TM, Giurea A, Verdonschot N, Janssen D. No effect in primary stability after increasing interference fit in cementless TKA tibial components. J Mech Behav Biomed Mater 2021; 118:104435. [PMID: 33721771 DOI: 10.1016/j.jmbbm.2021.104435] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 02/15/2021] [Accepted: 02/26/2021] [Indexed: 11/25/2022]
Abstract
Cementless total knee arthroplasty (TKA) implants rely on interference fit to achieve initial stability. However, the optimal interference fit is unknown. This study investigates the effect of using different interference fit on the initial stability of tibial TKA implants. Experiments were performed on human cadaveric tibias using a low interference fit of 350 μm of a clinically established cementless porous-coated tibial implant and a high interference fit of 700 μm. The Orthoload peak loads of gait and squat were applied to the specimens with a custom-made load applicator. Micromotions and gaps opening/closing were measured at the bone-implant interface using Digital Image Correlation (DIC) in 6 regions of interest (ROIs). Two multilevel linear mixed-effect models were created with micromotions and gaps as dependent variables. The results revealed no significant differences for micromotions between the two interference fits (gait p = 0.755, squat p = 0.232), nor for gaps opening/closing (gait p = 0.474, squat p = 0.269). In contrast, significant differences were found for the ROIs in the two dependent variables (p < 0.001), where more gap closing was seen in the posterior ROIs than in the anterior ROIs during both loading configurations. This study showed that increasing the interference fit from 350 to 700 μm did not influence initial stability.
Collapse
|
43
|
Firminger CR, Edwards WB. Effects of cyclic loading on the mechanical properties and failure of human patellar tendon. J Biomech 2021; 120:110345. [PMID: 33735631 DOI: 10.1016/j.jbiomech.2021.110345] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 02/18/2021] [Accepted: 02/22/2021] [Indexed: 12/31/2022]
Abstract
Patellar tendinopathy is a common overuse injury in sports such as volleyball, basketball, and long-distance running. Microdamage accumulation, in response to repetitive loading of the tendon, plays an important role in the pathophysiology of patellar tendinopathy. This damage presents mechanically as a reduction in Young's modulus and an increase in residual strain. In this study, 19 human patellar tendon samples underwent cyclic testing in load control until failure, segmented by four ramped tests where digital image correlation (DIC) was used to assess anterior surface strain distributions. Ramped tests were performed prior to cyclic testing and at timepoints corresponding to 10%, 20%, and 30% of cyclic stiffness reduction. Young's modulus significantly decreased and cyclic energy dissipation significantly increased over the course of cyclic testing. The DIC analysis illustrated a heterogeneous strain distribution, with strain concentrations increasing in magnitude and size over the course of cyclic testing. Peak stress and initial peak strain magnitudes significantly correlated with the number of cycles to failure (r2 = 0.65 and r2 = 0.57, respectively, p < 0.001); however, the rates of peak cyclic strain and modulus loss displayed the highest correlations with the number of cycles to failure (r2 = 96% and r2 = 86%, respectively, p < 0.001). The high correlation between the rates of peak cyclic strain and modulus loss suggest that non-invasive methods to continuously monitor tendon strain may provide meaningful predictions of overuse injury in the patellar tendon.
Collapse
|
44
|
Open cell polyurethane foam compression failure characterization and its relationship to morphometry. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 120:111754. [PMID: 33545895 DOI: 10.1016/j.msec.2020.111754] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 07/28/2020] [Accepted: 11/21/2020] [Indexed: 02/03/2023]
Abstract
Open cell polyurethane foams are often used as cancellous bone surrogates because of their similarities in morphology and mechanical response. In this work, open cell polyurethane foams of three different densities are characterized from morphometric and mechanical perspectives. The analysis of micro-computed tomography images has revealed that the high density foams present the greatest inhomogeneities. Those inhomogeneities promoted the failure location. We have used the finite element models as a tool to estimate elastic and failure properties that can be used in numerical modeling. Furthermore, we have assessed the anisotropic mechanical response of the foams, whose differences are related to the morphometric inhomogeneities. We found significant relationships between morphometry and the elastic and failure response. The detailed information about morphometry, elastic constants and strength limits provided in this work can be of interest to researchers and practitioners that often use these polyurethane foams in orthopedic implants and cement augmentation evaluations.
Collapse
|
45
|
de Ruiter L, Rankin K, Browne M, Briscoe A, Janssen D, Verdonschot N. Decreased stress shielding with a PEEK femoral total knee prosthesis measured in validated computational models. J Biomech 2021; 118:110270. [PMID: 33578052 DOI: 10.1016/j.jbiomech.2021.110270] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 08/20/2020] [Accepted: 01/16/2021] [Indexed: 11/28/2022]
Abstract
Due to their high stiffness, metal femoral implants in total knee arthroplasty may cause stress shielding of the peri-prosthetic bone, which can lead to loss of bone stock. Using a polymer (PEEK) femoral implant reduces the stiffness mismatch between implant and bone, and therefore has the potential to decrease strain shielding. The goal of the current study was to evaluate this potential benefit of PEEK femoral components in cadaveric experiments. Cadaveric femurs were loaded in a materials testing device, while a 3-D digital image correlation set-up captured strains on the surface of the intact femurs and femurs implanted with PEEK and CoCr components. These experimental results were used to validate specimen-specific finite element models, which subsequently were used to assess the effect of metal and PEEK femoral components on the bone strain energy density. The finite element models showed strain maps that were highly comparable to the experimental measurements. The PEEK implant increased strain energy density, relative to the preoperative bone and compared to CoCr. This was most pronounced in the regions directly under the implant and near load contact sites. These data confirm the hypothesis that a PEEK femoral implant can reduce peri-prosthetic stress shielding.
Collapse
|
46
|
Is the 0.2%-Strain-Offset Approach Appropriate for Calculating the Yield Stress of Cortical Bone? Ann Biomed Eng 2021; 49:1747-1760. [PMID: 33479788 DOI: 10.1007/s10439-020-02719-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 12/28/2020] [Indexed: 11/26/2022]
Abstract
The 0.2% strain offset approach is mostly used to calculate the yield stress and serves as an efficient method for cross-lab comparisons of measured material properties. However, it is difficult to accurately determine the yield of the bone. Especially when computational models require accurate material parameters, clarification of the yield point is needed. We tested 24 cortical specimens harvested from six bovine femora in three-point bending mode, and 11 bovine femoral cortical specimens in the tensile mode. The Young's modulus and yield stress for each specimen derived from the specimen-specific finite element (FE) optimization method was regarded as the most ideal constitutive parameter. Then, the strain offset optimization method was used to find the strain offset closest to the ideal yield stress for the 24 specimens. The results showed that the 0 strain offsets underestimated (- 25%) the yield stress in bending and tensile tests, while the 0.2% strain offsets overestimated the yield stress (+ 65%) in three-point bending tests. Instead, the yield stress determined by 0.007 and 0.05% strain offset for bending and tensile loading respectively, can effectively characterize the biomechanical responses of the bone, thereby helping to build an accurate FE model.
Collapse
|
47
|
Ernould C, Beausir B, Fundenberger JJ, Taupin V, Bouzy E. Integrated correction of optical distortions for global HR-EBSD techniques. Ultramicroscopy 2020; 221:113158. [PMID: 33338818 DOI: 10.1016/j.ultramic.2020.113158] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 10/20/2020] [Accepted: 10/27/2020] [Indexed: 11/26/2022]
Abstract
Optical distortions caused by camera lenses affect the accuracy of the elastic strains and lattice rotations measured by high-angular resolution techniques. This article introduces an integrated correction of optical distortions for global HR-EBSD/HR-TKD approaches. The digital image correlation analysis is directly applied to optically distorted patterns, avoiding the pattern pre-processing step conducted so far while preserving the numerical efficiency of the Gauss-Newton algorithm. The correction implementation is first described and its numerical cost is assessed considering a homography-based HR-EBSD approach. The correction principle is validated numerically for various levels of first-order radial distortion over a wide range of disorientation angles (0 to 14°) and elastic strain (0 to 5×10-2). The errors induced when neglecting such distortions as well as the influence of both the radial distortion coefficient and the pattern centre and optical centre locations are quantified. Even when both reference and target patterns are distorted, the correction appears necessary whatever the disorientation between those patterns. The required accuracy on the true distortion parameters for an effective correction is consequently determined.
Collapse
|
48
|
Collins CJ, Yang B, Crenshaw TD, Ploeg HL. Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness. J Mech Behav Biomed Mater 2020; 115:104253. [PMID: 33360160 DOI: 10.1016/j.jmbbm.2020.104253] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Revised: 11/08/2020] [Accepted: 12/06/2020] [Indexed: 12/15/2022]
Abstract
Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological error of the most common methods used to predict long-bone bending stiffness, more specifically, flexural rigidity (EI). Functional testing of a bi-material porcine bone surrogate, developed in a previous study, was conducted under four-point bending test conditions. The bone surrogate was imaged using computed tomography (CT) with an isotropic voxel resolution of 0.625 mm. Digital image correlation (DIC) of the bone surrogate was used to quantify the methodological error between experimental, analytical, and computational methods used to calculate EI. These methods include the application of Euler Bernoulli beam theory to mechanical testing and DIC data; the product of the bone surrogate composite bending modulus and second area moment of inertia; and finite element analysis (FEA) using computer-aided design (CAD) and CT-based geometric models. The methodological errors of each method were then compared. The results of this study determined that CAD-based FEA was the most accurate determinant of bone EI, with less than five percent difference in EI to that of the DIC and consistent reproducibility of the measured displacements for each load increment. CT-based FEA was most accurate for axial strains. Analytical calculations overestimated EI and mechanical testing was the least accurate, grossly underestimating flexural rigidity of long-bones.
Collapse
|
49
|
Berard D, Navarro JD, Bascos G, Harb A, Feng Y, De Lorenzo R, Hood RL, Restrepo D. Novel expandable architected breathing tube for improving airway securement in emergency care. J Mech Behav Biomed Mater 2020; 114:104211. [PMID: 33285451 DOI: 10.1016/j.jmbbm.2020.104211] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/30/2020] [Accepted: 11/15/2020] [Indexed: 11/17/2022]
Abstract
Life-saving interventions utilize endotracheal intubation to secure a patient's airway, but performance of the clinical standard of care endotracheal tube (ETT) is inadequate. For instance, in the current COVID-19 crisis, patients can expect prolonged intubation. This protracted intubation may produce health complications such as tracheal stenosis, pneumonia, and necrosis of tracheal tissue, as current ETTs are not designed for extended use. In this work, we propose an improved ETT design that seeks to overcome these limitations by utilizing unique geometries which enable a novel expanding cylinder. The mechanism provides a better distribution of the contact forces between the ETT and the trachea, which should enhance patient tolerability. Results show that at full expansion, our new ETT exerts pressures in a silicone tracheal phantom well within the recommended standard of care. Also, preliminary manikin tests demonstrated that the new ETT can deliver similar performance in terms of air pressure and air volume when compared with the current gold standard ETT. The potential benefits of this new architected ETT are threefold, by limiting exposure of healthcare providers to patient pathogens through streamlining the intubation process, reducing downstream complications, and eliminating the need of multiple size ETT as one architected ETT fits all.
Collapse
|
50
|
Nesbitt DQ, Siegel DN, Nelson SJ, Lujan TJ. Effect of age on the failure properties of human meniscus: High-speed strain mapping of tissue tears. J Biomech 2020; 115:110126. [PMID: 33359919 DOI: 10.1016/j.jbiomech.2020.110126] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 11/04/2020] [Indexed: 12/30/2022]
Abstract
The knee meniscus is a soft fibrous tissue with a high incidence of injury in older populations. The objective of this study was to determine the effect of age on the failure behavior of human knee meniscus when applying uniaxial tensile loads parallel or perpendicular to the primary circumferential fiber orientation. Two age groups were tested: under 40 and over 65 years old. We paired high-speed video with digital image correlation to quantify for the first time the planar strains occurring in the tear region at precise time points, including at ultimate tensile stress, when the tissue begins losing load-bearing capacity. On average, older meniscus specimens loaded parallel to the fiber axis had approximately one-third less ultimate tensile strain and absorbed 60% less energy to failure within the tear region than younger specimens (p < 0.05). Older specimens also had significantly reduced strength and material toughness when loaded perpendicular to the fibers (p < 0.05). These age-related changes indicate a loss of collagen fiber extensibility and weakening of the non-fibrous matrix with age. In addition, we found that when loaded perpendicular to the circumferential fibers, tears propagated near the planes of maximum tensile stress and strain. Whereas when loaded parallel to the circumferential fibers, tears propagated oblique to the loading axis, closer to the planes of maximum shear stress and strain. Our experimental results can assist the selection of valid failure criteria for meniscus, and provide insight into the effect of age on the failure mechanisms of soft fibrous tissue.
Collapse
|