26
|
Sinha A, Dhanjai, Stavrakis AK, Stojanović GM. Textile-based electrochemical sensors and their applications. Talanta 2022; 244:123425. [PMID: 35397323 DOI: 10.1016/j.talanta.2022.123425] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 03/13/2022] [Accepted: 03/29/2022] [Indexed: 10/18/2022]
Abstract
Textile and their composite-based functional sensors are extensively acknowledged and preferred detection platforms in recent times. Developing suitable methodologies for fabricating textile sensors can be achieved either by integration of conductive fibers and yarns into textiles using technologies such as weaving, knitting and embroidery; or by functionalization of textile materials with conductive nanomaterials/inks using printing or coating methods. Textile materials are gaining enormous attention for fabricating soft lab-on-fabric devices due to their unique features such as high flexibility, wear and wash resistance, mechanical strength and promising sensing performances. Owing to these collective properties, textile-based electrochemical transducers are now showcasing rapid and accurate electrical measurements towards real time point-of-care diagnostics and environmental monitoring applications. The present review provides a brief overview of key progress made in the field of developing textile materials and their composites-based electrochemical sensors and biosensors in recent years where electrode configurations are specifically based on either natural or synthetic fabrics. Different ways to fabricate and functionalize textiles for their application in electrochemical analysis are briefly discussed. The review ends with a conclusive note focusing on the current challenges in the fabrication of textile-based stable electrochemical sensors and biosensors.
Collapse
|
27
|
Hui N, Wang J, Wang D, Wang P, Luo X, Lv S. An ultrasensitive biosensor for prostate specific antigen detection in complex serum based on functional signal amplifier and designed peptides with both antifouling and recognizing capabilities. Biosens Bioelectron 2022; 200:113921. [PMID: 34973567 DOI: 10.1016/j.bios.2021.113921] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 12/18/2021] [Accepted: 12/24/2021] [Indexed: 12/31/2022]
Abstract
The development of biosensors capable of averting biofouling and detecting biomarkers in complex biological media remains a challenge. Herein, an ultralow fouling and highly sensitive biosensor based on specifically designed antifouling peptides and a signal amplification strategy was designed for prostate specific antigen (PSA) detection in human serum. A low fouling layer of poly(ethylene glycol) (PEG) doped the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was electrodeposited on the electrode surface, followed by the immobilization of streptavidin and further attachment of biotin-labelled peptides. The peptide was designed to include PSA specific recognition domain (HSSKLQK) and antifouling domain (PPPPEKEKEKE), and the terminal of the peptide was functionalized with -SH group. DNA functionalized gold nanorods (DNA/AuNRs) were then attached to the electrode, and methylene blue (MB) molecules were adsorbed to the DNA to form the signal amplifier. In the presence of PSA, the peptide was specifically cleaved and resulted in the loss of AuNRs together with DNA and MB, and thus significant decrease of the current signal. The biosensor exhibited a low limit of detection (LOD) of 0.035 pg mL-1 (S/N = 3), with a wide linear range from 0.10 pg mL-1 to 10.0 ng mL-1, and it was able to detect PSA in real human serum owing to the presence of the antifouling peptides, indicating great potential of the constructed biosensor for practical application.
Collapse
|
28
|
Li Y, Ma Y, Lichtfouse E, Song J, Gong R, Zhang J, Wang S, Xiao L. In situ electrochemical synthesis of graphene-poly(arginine) composite for p-nitrophenol monitoring. JOURNAL OF HAZARDOUS MATERIALS 2022; 421:126718. [PMID: 34339986 DOI: 10.1016/j.jhazmat.2021.126718] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/16/2021] [Accepted: 07/20/2021] [Indexed: 06/13/2023]
Abstract
Para-Nitrophenol (p-nitrophenol) is a common industrial pollutant occurring widely in water bodies, yet actual monitoring methods are limited. Herein we proposed a fully electrochemically in situ synthesized graphene-polyarginine composite functionalized screen printed electrode, as a novel p-nitrophenol sensing platform. The electrode was characterized by morphologic, spectrometric and electrochemical techniques. p-nitrophenol in both pure aqueous solution and real water samples was tested. Results show a detection limit as low as the nanomolar level, and display a linear response and high selectivity in the range of 0.5-1250 μM. Molecular simulation reveals a detailed synergy between graphene and poly-arginine. The preferable orientation of nitrophenol molecules on the graphene interface in the presence of poly-arginine induces H- and ionic binding. This sensor is an ideal prototype for p-nitrophenol quantification in real waters.
Collapse
|
29
|
Wang J, Xia Q, Wu J, Lin Y, Ju H. A sensitive electrochemical method for rapid detection of dengue virus by CRISPR/Cas13a-assisted catalytic hairpin assembly. Anal Chim Acta 2021; 1187:339131. [PMID: 34753581 DOI: 10.1016/j.aca.2021.339131] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 09/24/2021] [Accepted: 09/28/2021] [Indexed: 12/26/2022]
Abstract
Dengue fever caused by Dengue virus (DENV) infection has been widely popular, especially in tropical and subtropical areas. Rapid and sensitive diagnosis is the first priority for treatment of DENV infection. This work designed a signal amplification strategy for sensitive electrochemical detection of DENV by using a clustered regularly interspaced short palindromic repeats (CRISPR)/Cas13a system for catalytic hairpin assembly on electrode surface. The presence of target RNA could activate the cleavage activity of the CRISPR/Cas13a system to release the blocker silenced swing arms, which then hybridized with hairpin 1 (H1) immobilized on electrode surface to expose the pre-locked toehold domain of H1 for the hybridization of ferrocene-labeled hairpin 2 (H2-Fc). Eventually, a large number of H2-Fc were captured to the electrode to produce amperometric signal for achieving signal amplification. This method showed a linear detection range from 5 fM to 50 nM with a detection limit of 0.78 fM. The proposed assay was successfully used to detect DENV type 1 in total RNA sample extracted, indicating great potential for application in early clinical diagnostic.
Collapse
|
30
|
Lotfi Marchoubeh M, Cobb SJ, Abrego Tello M, Hu M, Jaquins-Gerstl A, Robbins EM, Macpherson JV, Michael AC, Fritsch I. Miniaturized probe on polymer SU-8 with array of individually addressable microelectrodes for electrochemical analysis in neural and other biological tissues. Anal Bioanal Chem 2021; 413:6777-6791. [PMID: 33961102 DOI: 10.1007/s00216-021-03327-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/15/2021] [Accepted: 04/01/2021] [Indexed: 01/08/2023]
Abstract
An SU-8 probe with an array of nine, individually addressable gold microband electrodes (100 μm long, 4 μm wide, separated by 4-μm gaps) was photolithographically fabricated and characterized for detection of low concentrations of chemicals in confined spaces and in vivo studies of biological tissues. The probe's shank (6 mm long, 100 μm wide, 100 μm thick) is flexible, but exhibits sufficient sharpness and rigidity to be inserted into soft tissue. Laser micromachining was used to define probe geometry by spatially revealing the underlying sacrificial aluminum layer, which was then etched to free the probes from a silicon wafer. Perfusion with fluorescent nanobeads showed that, like a carbon fiber electrode, the probe produced no noticeable damage when inserted into rat brain, in contrast to damage from an inserted microdialysis probe. The individual addressability of the electrodes allows single and multiple electrode activation. Redox cycling is possible, where adjacent electrodes serve as generators (that oxidize or reduce molecules) and collectors (that do the opposite) to amplify signals of small concentrations without background subtraction. Information about electrochemical mechanisms and kinetics may also be obtained. Detection limits for potassium ferricyanide in potassium chloride electrolyte of 2.19, 1.25, and 2.08 μM and for dopamine in artificial cerebral spinal fluid of 1.94, 1.08, and 5.66 μM for generators alone and for generators and collectors during redox cycling, respectively, were obtained.
Collapse
|
31
|
Li Y, Geng C, Xu X, Lv X, Fang Y, Wang N, Yang Y, Cui B. Construction of polythiophene-derivative films as a novel electrochemical sensor for highly sensitive detection of nitrite. Anal Bioanal Chem 2021; 413:6639-6647. [PMID: 34595556 DOI: 10.1007/s00216-021-03630-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 08/08/2021] [Accepted: 08/19/2021] [Indexed: 11/30/2022]
Abstract
Herein, a novel, convenient, and highly selective electrochemical sensor for determination of nitrite based on a polythiophene-derivative film-modified glassy carbon electrode (GCE) was established. In this work, 2,5-di-thiophen-3-yl-thiazolo[5,4-d]thiazole (DTT), a novel thiophene derivative, was synthesized and used to form an original and excellent polymer film (PolyDTTF) on GCE through one-step electropolymerization for the first time. The modified electrodes were characterized by electron microscopy (SEM), Fourier transform infra-red spectroscopy (FT-IR), UV-visible spectra, Raman spectroscopy, and electrochemical technologies, in which the electrochemical sensor based on PolyDTTF was successfully constructed and demonstrated a significant electrocatalytic effect on nitrite. The influence of pH value, electrodeposition scanning times, scanning speed, and potential on the electrochemical behavior of nitrite were investigated in detail. Furthermore, the nitrite sensor exhibits excellent responses proportional to nitrite concentrations (R2 = 0.9972) over a concentration range of 5.5 × 10-9 ~ 3.5 × 10-5 M with a detection limit (LOD) of 2 nM, and has extremely good anti-interference ability for nitrite detection. This proposed sensor can be used to detect nitrite in actual samples, opening the possibility for applications in the food industry and environmental analysis.
Collapse
|
32
|
Dutta MS, Mahapatra P, Ghosh A, Basu S. Estimation of the reducing power and electrochemical behavior of few flavonoids and polyhydroxybenzophenones substantiated by bond dissociation energy: a comparative analysis. Mol Divers 2021; 26:1101-1113. [PMID: 33993440 DOI: 10.1007/s11030-021-10232-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 05/05/2021] [Indexed: 11/30/2022]
Abstract
Oxidative stress that damages cellular components affects various organs including the brain. It is thus believed to play an active role in neurodegenerative diseases, wherein the intrinsic antioxidant enzymes metabolize toxic intermediates. For therapeutic purpose, instead of antioxidant enzymes, small organic compounds as antioxidants may be more effective. Here, reducing power and electrochemical behavior of some flavanols, flavanonols, flavones, flavonols and O-methylated flavonols have been estimated and confirmed by the calculated bond dissociation energy. Compared to other classes, flavonols exhibited increased reducing power that decreased with methylation of the oxygen atom in the B-ring. Gossypetin emerged as the most effective of these flavonols. Generally, compounds with two hydroxyl groups in two consecutive positions of the phenyl ring and an enolic group in the C-ring with more preference for the hydroxyl group in the ortho position with respect to each other in the catechol moiety showed major activity. 5 position of the A-ring showed the least effect on the activity. The present understanding therefore may be applied for identifying compounds to be used as scaffold for designing potent antioxidants.
Collapse
|
33
|
Su CK. Review of 3D-Printed functionalized devices for chemical and biochemical analysis. Anal Chim Acta 2021; 1158:338348. [PMID: 33863415 DOI: 10.1016/j.aca.2021.338348] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/28/2021] [Accepted: 02/18/2021] [Indexed: 12/28/2022]
Abstract
Recent developments in three-dimensional printing (3DP) have attracted the attention of analytical scientists interested in fabricating 3D devices having promising geometric functions to achieve desirable analytical performance. To break through the barrier of limited availability of 3DP materials and to extend the chemical reactivity and functionalities of devices manufactured using conventional 3DP, new approaches are being developed for the functionalization of 3D-printed devices for chemical and biochemical analysis. This Review discusses recent advances in the chemical functionalization schemes used in the main 3DP technologies, including (i) post-printing modification and surface immobilization of reactive substances on printed materials, (ii) pre-printing incorporation of reactive substances into raw printing materials, and (iii) combinations of both strategies, and their effects on the selectivity and/or sensitivity of related analytical methods. In addition, the state of the art of 3D-printed functionalized analytical devices for enzymatic derivatization and sensing, electrochemical sensing, and sample pretreatment applications are also reviewed, highlighting the importance of introducing new functional and functionalized materials to facilitate future 3DP-enabled manufacturing of multifunctional analytical devices.
Collapse
|
34
|
de Faria LV, Lisboa TP, Campos NDS, Alves GF, Matos MAC, Matos RC, Munoz RAA. Electrochemical methods for the determination of antibiotic residues in milk: A critical review. Anal Chim Acta 2021; 1173:338569. [PMID: 34172150 DOI: 10.1016/j.aca.2021.338569] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 04/03/2021] [Accepted: 04/21/2021] [Indexed: 12/20/2022]
Abstract
Several antibiotics have been applied to veterinary medicine due to their broad-spectrum of antibacterial activity and prophylactic power. Residues of these antibiotics can be accumulated in dairy cattle, in addition to promoting contamination of the environment and, in more serious cases, in milk, causing a public health problem. Different regulatory agencies establish maximum residue limits for these antibiotics in milk, so it becomes important to develop sensitive analytical methods for monitoring these compounds. Electrochemical techniques are important analytical tools in analytical chemistry because they present low cost, simplicity, high sensitivity, and adequate analytical frequency (sample throughput) for routine analyses. In this sense, this review summarizes the state of the art of the main electrochemical sensors and biosensors, instrumental techniques, and sample preparation used for the development of analytical methods, published in the last five years, for the monitoring of different classes of antibiotics: aminoglycosides, amphenicols, beta-lactams, fluoroquinolones, sulfonamides, and tetracyclines, in milk samples. The different strategies to develop electrochemical sensors and biosensors are critically compared considering their analytical features. The mechanisms of electrochemical oxidation/reduction of the antibiotics are revised and discussed considering strategies to improve the selectivity of the method. In addition, current challenges and future prospects are discussed.
Collapse
|
35
|
Ruan X, Wang Y, Kwon EY, Wang L, Cheng N, Niu X, Ding S, Van Wie BJ, Lin Y, Du D. Nanomaterial-enhanced 3D-printed sensor platform for simultaneous detection of atrazine and acetochlor. Biosens Bioelectron 2021; 184:113238. [PMID: 33878594 DOI: 10.1016/j.bios.2021.113238] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 03/15/2021] [Accepted: 04/06/2021] [Indexed: 12/13/2022]
Abstract
The widespread use of herbicides in agriculture and gardening causes environmental and safety issues such as water pollution. Thus, efficient and convenient analysis of the levels of herbicide residues is of significant importance. Here, we employed 3D-printing to design a multiplex immunosensor for simultaneous detection of two widely used herbicides, atrazine and acetochlor. Multiplexing was achieved through customization of a lateral flow immunoassay, and then integrated with an electrochemical analyzer for ultrasensitive detection. Quantification of herbicide residues was realized through the detection of a novel nanomaterial label, the mesoporous core-shell palladium@platium nanoparticle (Pd@Pt NP), for its outstanding peroxidase-like property. During the electrochemical analysis, the catalytic activity of Pd@Pt NPs on the redox reaction between thionin acetate and hydrogen peroxide provided an electrochemically driven signal that accurately indicated the level of herbicide residues. Using this Nanomaterial-enhanced multiplex electrochemical immunosensing (NEMEIS) system, simultaneous detection of atrazine and acetochlor was realized with a limit of detection of 0.24 ppb and 3.2 ppb, respectively. To further evaluate the feasibility, the optimized NEMEIS was employed for detection in atrazine and acetochlor residue-containing spiked samples, and an overall recovery with 90.8% - 117% range was obtained. The NEMEIS constructed with the aid of 3D-printing provides a rapid, precise, economical, and portable detection device for herbicides, and its success suggests potential broad applications in chemical analysis, biosensors and point-of-care monitoring.
Collapse
|
36
|
Electrochemical micropipette-tip for low-cost environmental applications: Determination of anionic surfactants through their interaction with methylene blue. Talanta 2021; 224:121732. [PMID: 33379002 DOI: 10.1016/j.talanta.2020.121732] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 09/26/2020] [Accepted: 10/01/2020] [Indexed: 11/22/2022]
Abstract
Miniaturization is one of the main requirements in the design of portable devices that allow in-field analysis. This is especially interesting in environmental monitoring, where the time of the sample-to-result process could be decreased considerably by approaching the analytical platforms to the sampling point. We employed traditional mass-produced and low-cost elements (micropipette tips and pins) in an out-of-box application to generate an innovative and cost-effective platform for analytical purposes. We have designed simple and easy-to-use electrochemical cells inside polypropylene micropipette tips with three stainless-steel pins acting as the working, reference and counter electrodes of a potentiostatic system. The pin acting as working electrode was previously coated with carbon ink, meanwhile the rest were used unmodified. In this way, electrochemical in-the-tip measurements were done directly using low volumes (μL) of sample. The devices showed good reproducibility, with a relative standard deviation of 7% (n = 5) for five different tip-based complete electrochemical cells. As a proof-of-concept, its utility has been probed by the determination of an anionic surfactant (sodium dodecyl sulphate, SDS) in water through its interaction with methylene blue (MB). Two different alternatives were presented based on the: 1) increase in the current intensity of the cathodic peak of MB due to the presence of SDS; 2) electrochemical determination of the MB remaining in the aqueous phase after extraction of the pair SDS-MB to an organic medium.
Collapse
|
37
|
Gunaseelan K, Jadhav DA, Gajalakshmi S, Pant D. Blending of microbial inocula: An effective strategy for performance enhancement of clayware Biophotovoltaics microbial fuel cells. BIORESOURCE TECHNOLOGY 2021; 323:124564. [PMID: 33360719 DOI: 10.1016/j.biortech.2020.124564] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 12/13/2020] [Accepted: 12/14/2020] [Indexed: 06/12/2023]
Abstract
Performance of clayware Biophotovoltaics (BPVs) with three variants of inocula namely anoxygenic photosynthetic bacteria (APB) rich Effective microbes (EM), Up-flow anaerobic sludge blanket reactor (UASB) sludge, SUPER-MIX the blend of EM and UASB inoculum were evaluated on the basis of electrical output and pollutant removal. SUPER-MIX inocula with microbial community comprising of 28.42% APB and 71.58% of other microbes resulted in peak power density of 275 mW/m2, 69.3 ± 1.74% Coulombic efficiency and 91 ± 3.96% organic matter removal. The higher performance of the SUPER-MIX than EM and UASB inocula was due to the syntrophic associations of the various APBs and other heterogenous microorganisms in perfect blend which improved biocatalytic electron transfer, electro-kinetic activities with higher redox current and bio-capacitance. The promising performance of clayware BPVs with SUPER-MIX inocula indicate the possibility of BPVs to move towards the scale-up process to minimize the investment towards pure culture by effective blending strategies of inocula.
Collapse
|
38
|
Yao L, He L, Yang Y, Zhang Y, Liu Z, Liang L, Piao Y. Nanobiochar paper based electrochemical immunosensor for fast and ultrasensitive detection of microcystin-LR. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 750:141692. [PMID: 32846246 DOI: 10.1016/j.scitotenv.2020.141692] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 07/25/2020] [Accepted: 08/12/2020] [Indexed: 05/28/2023]
Abstract
A portable, cheap and sensitive paper type electrochemical immunosensor was developed with conductive nanobiochar paper as the conductive layer and utilized for sensitive detection of microcystin-LR (MCLR) toxin in water. The paper immunosensor was constructed by coating of highly conductive and dispersible nanobiochar particle (nBC) and anti-MCLR antibody on the filter paper via dipping-drying method. The presence of MCLR could be specifically quantified amperometrically by the nBC-paper immunosensor with the response time of less than 5 min, and the lowest detection limit of 17 pM (0.017 μg/L) was achieved. Moreover, the proposed immunosensor exhibited high selectivity, reproducibility and storage stability, and was also used for environmental water detection with satisfactory recovery. The successful fabrication of low cost and ubiquitous biochar based paper type electrochemical immunosensing system would have significant value for the development of highly cost-effective electrochemical device.
Collapse
|
39
|
Kim JH, Koh B, Ahn DG, Lee SJ, Park TJ, Park JP. A screening study of high affinity peptide as molecular binder for AXL, tyrosine kinase receptor involving in Zika virus entry. Bioelectrochemistry 2020; 137:107670. [PMID: 32971483 DOI: 10.1016/j.bioelechem.2020.107670] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/02/2020] [Accepted: 09/03/2020] [Indexed: 11/24/2022]
Abstract
The recent extensive spread of Zika virus has led to increased interest in the development of early diagnostic tests. To the best of our knowledge, this is the first study to demonstrate the successful use of phage display to identify affinity peptides for quantitative analysis of AXL, a tyrosine kinase receptor involved in Zika virus entry. Biopanning of M13 phage library successfully identified a high affinity peptide, with the sequence AHNHTPIKQKYL. To study the feasibility of using free peptides for molecular recognition, we synthesized a series of amino acid-substituted peptides and examined their binding affinity for AXL using electrochemical impedance spectroscopy and square wave voltammetry. Most synthetic peptides had non-identical random coil structures based on circular dichroism spectroscopy. Of the peptides tested, AXL BP1 exhibited nanomolar binding affinity for AXL. To verify whether AXL BP1 could be used as a peptide inhibitor at the cellular level, two functional tests were carried out: a WST assay for cell viability and qRT-PCR for quantification of RNA levels in Zika virus-infected Huh7 cells. The results showed that AXL BP1 had low cytotoxicity and could block Zika virus entry. These results indicate that newly identified affinity peptides could potentially be used for the development of Zika virus entry inhibitors.
Collapse
|
40
|
Darwish IA, Darwish HW, Bakheit AH, Al-Kahtani HM, Alanazi Z. Irbesartan (a comprehensive profile). PROFILES OF DRUG SUBSTANCES, EXCIPIENTS, AND RELATED METHODOLOGY 2020; 46:185-272. [PMID: 33461698 DOI: 10.1016/bs.podrm.2020.07.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Irbesartan, (2-butyl-3-({4-[2-(2H-1,2,3,4-tetrazol-5-yl)phenyl]phenyl}methyl)-1,3-diazaspiro[4.4]non-1-en-4-one), is a member of non-peptide angiotensin II receptor antagonists used worldwide in the treatment of hypertension and diabetic nephropathy in hypertensive patients with type 2 diabetes, elevated serum creatinine, and proteinuria. Irbesartan can be used alone or in combination with other antihypertensive agents (e.g., hydrochlorothiazide). These combination products are indicated for hypertension in patients with uncontrolled hypertension with monotherapy or first line in patients not expected to be well controlled with monotherapy. Irbesartan is also indicated for the treatment of diabetic nephropathy in patients with type 2 diabetes and hypertension, an elevated serum creatinine, and proteinuria. Irbesartan exerts its action mainly via a selective blockade action on AT1 receptors and the consequent reduced pressor effect of angiotensin II. This article discusses, by a critical comprehensive review of the literature on irbesartan in terms of its description, names, formulae, elemental composition, appearance, and therapeutic uses. The article also discusses the methods for preparation of irbesartan, its physical-chemical properties, analytical methods for its determination, pharmacological-toxicological properties, and dosing information.
Collapse
|
41
|
Electrodeposited poly(3,4-ethylenedioxythiophene) doped with graphene oxide for the simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid. Mikrochim Acta 2020; 187:94. [PMID: 31902014 DOI: 10.1007/s00604-019-4083-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Accepted: 12/13/2019] [Indexed: 01/20/2023]
Abstract
Poly(3,4-ethylenedioxythiophene) (PEDOT) films were electrodeposited by cyclic voltammetry on a glassy carbon electrode (GCE) in aqueous solution. Three kinds of supporting electrolytes were used, viz. graphene oxide (GO), phosphate buffered saline (PBS), and GO in PBS, respectively. The surface morphology of the modified electrodes was characterized by scanning electron microscopy. The electrochemical performance of the modified electrodes was investigated by cyclic voltammetry and electrochemical impedance spectroscopy by using the hexacyanoferrate redox system. The results demonstrate that the PEDOT-GO/GCE, which was electropolymerized in aqueous solutions containing EDOT and GO, shows the best electrochemical activities compared with other modified electrodes. The electrochemical behaviors of ascorbic acid (AA), dopamine (DA) and uric acid (UA) were investigated by cyclic voltammetry. The PEDOT-GO/GCE exhibits enhanced electrocatalytic activities towards these important biomolecules. Under physiological pH conditions and in the mixed system of AA, DA and UA, the modified GCE exhibits the following figures of merit: (a) a linear voltammetric response in the concentration ranges of 100-1000 μM for AA, 6.0-200 μM for DA, and 40-240 μM for UA; (b) well separated oxidation peaks near 31, 213 and 342 mV (vs. saturated Ag/AgCl) for AA, DA and UA, respectively; and (c) detection of limits (at S/N = 3) of 20, 2.0 and 10 μM. The results demonstrate that GO, based on its relatively large number of anionic sites, can be used as the sole weak electrolyte and charge balance dopant for the preparation of functionally doped conducting polymers by electrodeposition. Graphical abstractSchematic representation of a nanostructure composed of hybrid conducting polymer PEDOT-GO nanocomposites, and its application to simultaneous determination of ascorbic acid, dopamine and uric acid.
Collapse
|
42
|
Du Y, Ma H, Huang L, Pan Y, Huang J, Liu Y. Electrochemical characteristics of the decolorization of three dyes by laccase mediator system (LMS) with synthetic and natural mediators. CHEMOSPHERE 2020; 239:124779. [PMID: 31521934 DOI: 10.1016/j.chemosphere.2019.124779] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 09/02/2019] [Accepted: 09/04/2019] [Indexed: 06/10/2023]
Abstract
Laccase mediator system (LMS), a very attractive candidate for refractory organics biodegradation, harbors tremendous potential on industry application. However, the performance of LMS usually varies with the discrepancy of mediators and substrates in their chemical structures. Here, we adopt electrochemical analysis that is able to assess the degradation performance of various LMS on three different dyes by quantitative analysis of reaction outcome. Two mechanisms were suggested to explain the grafting of three mediators (1-Hydroxybenzotriazole, Violuric Acid and Acetosyringone), involving the transformation of proton or electron to produce active moieties, which subsequently react with target substrates. A thorough electrochemical insight into the redox features of mediators and its change in the presence of laccase and substrates were carried out using electrochemical analysis. The effectiveness of each kind of LMS on substrates was preliminarily evaluated by analyzing the change of the peak current and potential of mediators. The actual conversion rate of dyes was used to verify the analysis results, which confirms the important role of the stability of the oxidized form as well as their redox potential of the mediators in determining the mechanism of substrate oxidation. The application of electrochemical analysis in efficiency evaluation of LMS shed new light on effective selection of suitable mediators for degradation of refractory organics. It was therefore possible to prejudge the efficacy of LMS by analyzing the electrochemical parameters of target substances and mediators, which undoubtedly has broad further application prospects of LMS.
Collapse
|
43
|
Alteration of surface pressure of macromolecular monolayer at the air-water interface and electrochemical impedance characteristics. Colloids Surf B Biointerfaces 2019; 187:110638. [PMID: 31767413 DOI: 10.1016/j.colsurfb.2019.110638] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/23/2019] [Accepted: 11/09/2019] [Indexed: 11/23/2022]
Abstract
Proteins are very important biological macromolecules, specific in their functions essential for many biological activities. Proteins are among the most vital components of all living matters with thousands of different types, and they are very specific in their nature which makes them important for usage in many biotechnological, biomedical, and food processing applications. Langmuir monolayer studies provide the characteristics of monolayer at the air-liquid interface. Langmuir monolayer of protein is affected by the molecular weight, macromolecular structure, denaturation and its purity. The interaction of the protein with other molecules greatly affects the behaviour of monolayer. Coconut oil layer at the air-water interface was prepared with different sub-phases including casein protein and whey protein. Wilhelmy plate measurement technique has been used to measure the surface pressure of the monolayer at the air-liquid interface. Experiments were carried out to study the stability using electrochemical impedance measurements. The electrostatic forces dominated the coconut oil - protein interaction, and the interface of macromolecules were controlled by expansion and compression. The macromolecules were adsorbed with a preferential orientation at the interface, and the stability of colloidal dispersions was governed by the intermolecular interactions. The stability using electrochemical impedance spectroscopy on the selected protein macromolecules along with other analysis were performed by varying various parameters.
Collapse
|
44
|
Zhong XL, Wen SH, Wang Y, Luo YX, Li ZM, Liang RP, Zhang L, Qiu JD. Colorimetric and electrochemical arsenate assays by exploiting the peroxidase-like activity of FeOOH nanorods. Mikrochim Acta 2019; 186:732. [PMID: 31667627 DOI: 10.1007/s00604-019-3863-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Accepted: 09/19/2019] [Indexed: 01/07/2023]
Abstract
The authors describe an electrochemical and an optical method for the determination of As(V) by using iron oxyhydroxide (FeOOH) nanorods that display peroxidase-mimicking activity. The nanorods catalyze the oxidation of substrate ABTS by H2O2 to form a green product with an absorption maximum at 418 nm. If, however, As(V) is electrostatically adsorbed on the nanorods, the oxidation is gradually inhibited. A colorimetric assay was worked out based on these findings. Response is linear in the 0 to 8 ppb and 8 to 200 ppb As(V) concentration range, and the detection limit is 0.1 ppb. Even higher sensitivity is achieved in an electrochemical method which is based on the excellent electrical conductivity of FeOOH nanorods. Electrochemical analysis of As(V) was achieved by first adsorbing As(V) on the nanorods. This inhibits the ABTS reduction current signal, best measured at a potential of 150 mV (vs. Ag/AgCl). The linear range extends from 0.04 to 200 ppb, and the detection limit is as low as 12 ppt. Graphical abstract Schematic representation of FeOOH nanorod-based colorimetric and electrochemical assays for arsenate (As(V)). As(V) adsorbed on FeOOH nanorods inhibits the peroxidase-mimicking activity of nanorods, and a colorimetric and electrochemical dual-signal assay was constructed to achieve sensitive determination of As(V).
Collapse
|
45
|
A taurine-functionalized 3D graphene-based foam for electrochemical determination of hydrogen peroxide. Talanta 2019; 208:120356. [PMID: 31816730 DOI: 10.1016/j.talanta.2019.120356] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 09/09/2019] [Accepted: 09/14/2019] [Indexed: 02/06/2023]
Abstract
We present a synthesis approach of taurine-functionalized graphene foam (a-NSGF) using hydrothermal reduction, freeze-drying and high temperature annealing. The higher temperature in annealing allowed the N/S atoms of taurine enter into the graphene lattice, which improves its electrocatalytic activity greatly. The a-NSGF consisting of taurine that modified into 3D layers of graphene and endow is of the rapid sensitive to hydrogen peroxide (H2O2). The electrode using a-NSGF modification reveals highly sensitive and stable towards the concentration change of H2O2 due to the stable 3D structure and good electrical conductivity of a-NSGF. A linear correlation between H2O2 concentration and the electrochemical signal is found to be in a range from 1.5 to 300 μM and the correlation coefficient is R2 = 0.999. The modified electrode has been applied in the determination of H2O2 in rain samples and the results have been compared with the China National Standard Method. The recoveries range from 94.6% to 106.7%. These results show that the proposed sensor is promising for the development of novel electrochemical sensing for H2O2 determination.
Collapse
|
46
|
Ahuir-Torres JI, Simandjuntak S, Bausch N, Farrar A, Webb S, Nash A, Thomas B, Muna J, Jonsson C, Matthew D. Corrosion threshold data of metallic materials in various operating environment of offshore wind turbine parts (tower, foundation, and nacelle/gearbox). Data Brief 2019; 25:104207. [PMID: 31440542 PMCID: PMC6699462 DOI: 10.1016/j.dib.2019.104207] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 05/30/2019] [Accepted: 06/25/2019] [Indexed: 11/29/2022] Open
Abstract
This paper outlines corrosion thresholds for different environmental conditions of metallic materials commonly used in the tower, foundation, and nacelle/gearbox of an offshore wind turbine. These threshold values were derived from laboratory corrosion testing employing electrochemical analysis techniques, using the media/solvents that are representative to the operating environment of those wind turbine parts, such as seawater, grease, oils/lubricants, or their combination, at room temperature and at 328K. These values can provide an indication when general/local corrosion or protective film/surface damages have occurred. They can thus be utilised for detecting and monitoring corrosion at certain locations in the wind turbine structure. The presented data have been verified and validated to ensure their repeatability and reliability by means of numerous laboratory tests in accordance to the relevant engineering test standards and an extensive literature/published data review.
Collapse
|
47
|
Kumar Y, Pramanik P, Das DK. Electrochemical detection of paracetamol and dopamine molecules using nano-particles of cobalt ferrite and manganese ferrite modified with graphite. Heliyon 2019; 5:e02031. [PMID: 31321329 PMCID: PMC6612601 DOI: 10.1016/j.heliyon.2019.e02031] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 05/13/2019] [Accepted: 06/28/2019] [Indexed: 01/23/2023] Open
Abstract
Some electrodes for efficient detection of paracetamol and dopamine were developed from nano sized material of cobalt ferrite (np-CoFe2O4) and manganese ferrite (np-MnFe2O4). These oxides were synthesized by combustion method using cobalt nitrate, manganese acetate and ferric nitrate as precursors in the presence of sugar and ethanolamine. The crystallite size, shape and morphology of nano material were characterized by X-ray diffraction pattern (XRD), field emission scanning electron microscopy (FESEM) and energy-dispersive X-ray spectroscopy (EDS) techniques. The crystallite sizes of synthesized nano-particles (nps) were in the range from 10 to 12 nm (calculated using Debye-Scherrer equation) with cubic crystal system. These particles were utilized as electrode modified with graphite for simultaneous detection of paracetamol and dopamine through cyclic voltammetry and Differential pulse voltammetry techniques and was found to be superior to reported literatures. The minimum detection limit of paracetamol and dopamine at CoFe2O4/GP electrode were 250 nM and 350 nM while at MnFe2O4/GP electrode it was 300 nM and 400 nM, respectively. Both the electrodes exhibited the linearity range from3 μM to 200 μM & 3 μM-160 μM for paracetamol and 3 μM-180 μM & 5 μM to 200 for dopamine, respectively. Two oxidation peaks of paracetamol and dopamine were well separated in phosphate buffer (pH = 6) in mixture with 100 mVs-1 and 50 mVs-1 scan rate for cyclic voltammetry and Differential pulse voltammetry, respectively. Both the electrodes demonstrated satisfactory results in real samples of paracetamol and dopamine.
Collapse
|
48
|
Femtomolar electroanalysis of a breast cancer biomarker HER-2/neu protein in human serum by the cellulase-linked sandwich assay on magnetic beads. Anal Chim Acta 2019; 1077:140-149. [PMID: 31307703 DOI: 10.1016/j.aca.2019.05.052] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Revised: 05/19/2019] [Accepted: 05/22/2019] [Indexed: 02/06/2023]
Abstract
In cancer diagnostics, specific analysis of blood-circulating proteins biomarkers of cancer is often complicated both by their inherently low concentrations and by strong interference from serum/blood proteins. Here, we report a simple and robust electrochemical cellulase-linked sandwich assay on magnetic beads (MBs) for fM-sensitive analysis of the Human Epidermal growth factor Receptor-2 HER-2/neu protein that is over-expressed in most aggressive breast cancers. In the assay, a sandwich is assembled by capturing HER-2/neu on either antibody (Ab) or aptamer-modified MBs accompanied by reaction with the second Ab or aptamer labelled with cellulase. On application of the sandwiches assembled on MBs onto a cost-effective graphite electrode modified with an insulating nitrocellulose film, the cellulase label digests the film. This results in the pronounced changes in the electrical properties of the modified electrodes. The chronocoulometrically-measured extent of the produced changes was proportional to the 10-15-10-10 M HER-2/neu in the analyzed samples, and down to 1 fM of HER-2/neu could be detected in human serum samples in an overall less than 3 h assay. The developed simple and electrochemically label-free methodology is general and can be easily adapted for testing of any other protein.
Collapse
|
49
|
Zhao Z, Li C, Wu H. Reduced graphene oxide nanosheets modified with plasmonic gold-based hybrid nanostructures and with magnetite (Fe 3O 4) nanoparticles for cyclic voltammetric determination of arsenic(III). Mikrochim Acta 2019; 186:226. [PMID: 30848370 DOI: 10.1007/s00604-019-3328-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Accepted: 02/16/2019] [Indexed: 11/24/2022]
Abstract
The authors have fabricated reduced graphene oxide nanosheets (rGO) supported with Fe3O4 nanoparticles and Ag/Au hollow nanoshells. The material was placed on a glassy carbon electrode which is shown to enable highly sensitive determination of As(III) which is first preconcentrated from solution at a potential of -0.35 V (versus Ag/AgCl) for 100 s. The electrode, typically operated at a working potential as low as 0.06 V, has a linear response in the 0.1 to 20 ppb As(III) concentration range and a 0.01 ppb detection limit. The electrochemical sensitivity is 52 μA ppb-1. The high sensitivity is assumed to be the result of various synergistic effects. The method was applied to ultratrace (0.1 ppt) determination of As(III) in real water samples. Graphical abstract The hybrid displays a wide linear response in the 0.1 to 20 ppb As(III) concentration range and a 0.01 ppb detection limit. The high sensitivity is attributed to various synergistic effects. The method was applied to ultratrace determination of As(III) in real water samples.
Collapse
|
50
|
Zhang J, Zhou JP, Dai XH, Liu GZ, Zhang SY. Electrochemical preparation of two nanostructured poly(sulfosalicylic acid) films with different morphologies and properties for selective sensing of dopamine: Comparative study. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 77:151-158. [PMID: 28532016 DOI: 10.1016/j.msec.2017.03.237] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2016] [Revised: 12/19/2016] [Accepted: 03/25/2017] [Indexed: 10/19/2022]
Abstract
Two nanostructured poly(sulfosalicylic acid) (PSA) films were synthesized from room temperature ionic liquid (RTIL) or aqueous solution on a glassy carbon electrode (GCE) via potentiodynamic electropolymerization. The morphology and properties of the PSA films were characterized with scanning electron microscopy (SEM), scanning probe microscopy (SPM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). It was found that solvent had a major influence on the morphology and electrochemical properties of the resultant PSA films. The PSA(Ι) film, which was prepared from RTIL, consists of granular particles with cracks, whereas the PSA(II) film prepared from aqueous solution consists of nano-triangles with a more compact surface. The blocking effect of the PSA(Ι) film for the [Fe(CN)6]3-/4- electrochemical probe is much stronger, and a remarkably enhanced voltammetric response of the [Ru(NH3)6]3+ electrochemical probe can be observed for the PSA(II) film. When it is used to detect dopamine in the presence of a high concentration of ascorbic acid, PSA(II)/GCE has three linear parts with better discrimination and a detection limit of 0.03μM. For PSA(Ι)/GCE, there are two linear parts with a detection limit of 0.05μM. However, the reproducibility and storage stability of PSA(Ι)/GCE are better than those of PSA(ΙI)/GCE.
Collapse
|