26
|
Park J, Kim T. Acute effect of taping on plantar pressure characteristics in athletes with exercise-induced leg pain: a description and comparison of groups. PHYSICIAN SPORTSMED 2019; 47:212-219. [PMID: 30462925 DOI: 10.1080/00913847.2018.1547085] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
OBJECTIVES Foot pronation is considered as a potential risk factor of lower leg overuse injury. This study aimed to identify plantar pressure characteristics of elite athletes with exercise-induced leg pain in throwing athletic disciplines, and to verify the acute effect of taping for restricting foot pronation by analyzing the plantar pressure characteristics. METHODS This study was designed as a description and comparison of throwing athletic athletes. Participants were divided into exercise-induced leg pain (ELP group, n = 17) and control groups (CON group, n = 14). Plantar pressure variables (contact area, maximum force, and peak pressure) at eight-foot regions in athletes' supporting leg were recorded during standing on one leg and a natural walk before and after applying anti-pronation or sham taping techniques. RESULTS There are significant difference of contact area, maximal force, and peak pressure in some regions of their foot between the ELP and CON groups. But the anti-pronation taping decreased only the peak pressure in lateral midfoot of CON group during a natural walk (p = 0.002). CONCLUSION The anti-pronation taping technique may not be effective preventive strategy from the exercise-induced leg pain, such as shin splints.
Collapse
|
27
|
Chander NG, Biswas A. Clinical evaluation of differences in proximal contact strength of various fixed dental prosthesis materials. Indian J Dent Res 2019; 29:739-743. [PMID: 30589001 DOI: 10.4103/ijdr.ijdr_21_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Objective The study compared the proximal contact strength (CS) of different fixed dental prosthesis (FDP) materials. Materials and Methods Thirty volunteers participated in this study with definitive inclusion and exclusion criteria. Participants were divided into full metal, zirconia, and metal ceramic groups. The CS between the natural teeth and the maxillary posterior quadrant FDP was measured with force gauge. The data were evaluated with one-way analysis of variance test, and Tukey's honest significant difference post hoc was done to compare the mean values. Paired samples t-test was used to compare the mean values between pre- and postoperative CS. Results The postoperative CS observed in the full metal group in premolar was 0.320 ± 0.1092 N and in second molar was 0.385 ± 0.1130 N. CS obtained with zirconia FDP in both premolar (0.679 ± 0.0927 N) and molar (0.770 ± 0.0960 N) was highest among all groups. The results were statistically significant (P < 0.001). Conclusion Postoperative CS was greater in zirconia when compared with metal and metal ceramic FDP. Clinical Relevance FDP materials had acceptable CS. Zirconia is preferable for optimal CS.
Collapse
|
28
|
Lange T, Taghizadeh E, Knowles BR, Südkamp NP, Zaitsev M, Meine H, Izadpanah K. Quantification of patellofemoral cartilage deformation and contact area changes in response to static loading via high-resolution MRI with prospective motion correction. J Magn Reson Imaging 2019; 50:1561-1570. [PMID: 30903682 DOI: 10.1002/jmri.26724] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Revised: 02/26/2019] [Accepted: 02/26/2019] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Higher-resolution MRI of the patellofemoral cartilage under loading is hampered by subject motion since knee flexion is required during the scan. PURPOSE To demonstrate robust quantification of cartilage compression and contact area changes in response to in situ loading by means of MRI with prospective motion correction and regularized image postprocessing. STUDY TYPE Cohort study. SUBJECTS Fifteen healthy male subjects. FIELD STRENGTH 3 T. SEQUENCE Spoiled 3D gradient-echo sequence augmented with prospective motion correction based on optical tracking. Measurements were performed with three different loads (0/200/400 N). ASSESSMENT Bone and cartilage segmentation was performed manually and regularized with a deep-learning approach. Average patellar and femoral cartilage thickness and contact area were calculated for the three loading situations. Reproducibility was assessed via repeated measurements in one subject. STATISTICAL TESTS Comparison of the three loading situations was performed by Wilcoxon signed-rank tests. RESULTS Regularization using a deep convolutional neural network reduced the variance of the quantified relative load-induced changes of cartilage thickness and contact area compared to purely manual segmentation (average reduction of standard deviation by ∼50%) and repeated measurements performed on the same subject demonstrated high reproducibility of the method. For the three loading situations (0/200/400 N), the patellofemoral cartilage contact area as well as the mean patellar and femoral cartilage thickness were significantly different from each other (P < 0.05). While the patellofemoral cartilage contact area increased under loading (by 14.5/19.0% for loads of 200/400 N), patellar and femoral cartilage thickness exhibited a load-dependent thickness decrease (patella: -4.4/-7.4%, femur: -3.4/-7.1% for loads of 200/400 N). DATA CONCLUSION MRI with prospective motion correction enables quantitative evaluation of patellofemoral cartilage deformation and contact area changes in response to in situ loading. Regularizing the manual segmentations using a neural network enables robust quantification of the load-induced changes. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1561-1570.
Collapse
|
29
|
Influence of humeral abduction angle on axial rotation and contact area at the glenohumeral joint. J Shoulder Elbow Surg 2019; 28:570-577. [PMID: 30573432 DOI: 10.1016/j.jse.2018.08.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 08/10/2018] [Accepted: 08/19/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although the elevation angle of the arm affects the range of rotation, it has not been evaluated up to the maximal abduction angle. In this study we conducted an evaluation up to maximal abduction and determined the contact patterns at the glenohumeral (GH) joint. METHODS Fourteen healthy volunteers (12 men and 2 women; mean age, 26.9 years) with normal shoulders (14 right and 8 left) were instructed to rotate their shoulders at 0°, 90°, 135°, and maximal abduction for each shoulder at a time. Using 2-dimensional and 3-dimensional single-plane image registration, the internal rotation (IR), external rotation (ER), and range of motion (ROM; ie, axial rotations) at the thoracohumeral (TH) and GH joints, and the contribution ratio (%ROM = GH-ROM/TH-ROM) were calculated for each abduction. The glenoid position with respect to the humeral head was also analyzed. RESULTS The TH-IR and TH-ER shifted toward an ER with increasing abduction angle, whereas the TH-ROM significantly decreased except at abduction between 0° and 90° (P < .001). The GH-IR and GH-ROM significantly decreased except at abduction between 0° and 90° (P < .001), but the GH-ER remained constant regardless of the abduction. The contribution ratio exceeded 80% for every abduction angle. The glenoid moved on the central and posterior areas of the humeral head at 0° and 90° abduction, respectively, and on the posterosuperior and anterosuperior areas at 135° and maximal abduction, respectively. CONCLUSION Our results provide new knowledge about wide axial rotation up to maximal abduction and constant GH-ER at any abduction.
Collapse
|
30
|
Willinger L, Foehr P, Achtnich A, Forkel P, Voss A, Liska F, Lacheta L, Imhoff AB, Burgkart R. Effect of Lower Limb Alignment in Medial Meniscus-Deficient Knees on Tibiofemoral Contact Pressure. Orthop J Sports Med 2019; 7:2325967118824611. [PMID: 30800688 PMCID: PMC6378645 DOI: 10.1177/2325967118824611] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Background: Degenerative medial meniscal tears and subsequent partial meniscal resection compromise meniscal function and lead to an overload of the medial compartment. In addition, lower limb alignment plays a key role in load distribution between the medial and lateral knee compartments, and varus alignment is a potential risk factor for medial osteoarthritis. Purpose/Hypothesis: The purpose of this biomechanical study was to investigate the effect of valgus and varus alignment on peak pressure and contact area in knees with concomitant horizontal medial meniscal tears and subsequent leaflet resection. It was hypothesized that varus alignment in combination with meniscal loss leads to the highest peak pressure within the medial compartment. Study Design: Controlled laboratory study. Methods: Six fresh-frozen human cadaveric knees were axially loaded using a 1000-N compressive load in full extension with the mechanical axis rotated to intersect the tibial plateau at 40%, 45%, 50%, 55%, and 60% of its width (TPW) to simulate varus and valgus alignment. Tibiofemoral peak contact pressure and contact area of the medial and lateral compartments were determined using pressure-sensitive foils in each of 4 different meniscal conditions: intact, 15-mm horizontal tear of the posterior horn, inferior leaflet resection, and resection of both leaflets. Results: The effect of alignment on peak pressure (normalized to the neutral axis) within the medial compartment in cases of an intact meniscus was measured as follows: varus shift resulted in a mean increase in peak pressure of 18.5% at 45% of the TPW and 37.4% at 40% of the TPW, whereas valgus shift led to a mean decrease in peak pressure of 8.7% at 55% of the TPW and 23.1% at 60% of the TPW. Peak pressure changes between the intact meniscus and resection within the medial compartment was less in valgus-aligned knees (0.21 MPa at 60% TPW, 0.59 MPa at 50% TPW, and 0.76 MPa at 40% TPW). Contact area was significantly reduced after partial meniscal resection in the neutral axis (intact, 553.5 ± 87.6 mm2; resection of both leaflets, 323.3 ± 84.2 mm2; P < .001). This finding was consistent in any alignment. Conclusion: Both partial medial meniscal resection and varus alignment led to an increase in medial compartment peak pressure. Valgus alignment prevented medial overloading by decreasing contact pressure even after partial meniscal resection. A horizontal meniscal tear did not influence peak pressure and contact area even in varus alignment. Clinical Relevance: As a clinical consequence, partial meniscal resection should be avoided to maintain the original biomechanical behavior, and the mechanical axis should be taken into account if partial meniscectomy is necessary.
Collapse
|
31
|
Yuan XN, Liang WD, Zhou FH, Li HT, Zhang LX, Zhang ZQ, Li JJ. Comparison of walking quality variables between incomplete spinal cord injury patients and healthy subjects by using a footscan plantar pressure system. Neural Regen Res 2019; 14:354-360. [PMID: 30531020 PMCID: PMC6301183 DOI: 10.4103/1673-5374.244798] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
The main goal of spinal cord rehabilitation is to restore walking ability and improve walking quality after spinal cord injury (SCI). The spatiotemporal parameters of walking and the parameters of plantar pressure can be obtained using a plantar pressure analysis system. Previous studies have reported step asymmetry in patients with bilateral SCI. However, the asymmetry of other parameters in patients with SCI has not been reported. This was a prospective, cross-sectional study, which included 23 patients with SCI, aged 48.1 ± 14.5 years, and 28 healthy subjects, aged 47.1 ± 9.8 years. All subjects underwent bare foot walking on a plantar pressure measurement device to measure walking speed and spatiotemporal parameters. Compared with healthy subjects, SCI patients had slower walking speed, longer stride time and stance time, larger stance phase percentage, and shorter stride length. The peak pressures under the metatarsal heads and toe were lower in SCI patients than in healthy subjects. In the heel, regional impulse and the contact area percentage in SCI patients were higher than those in healthy subjects. The symmetry indexes of stance time, step length, maximum force, impulse and contact area were increased in SCI patients, indicating a decline in symmetry. The results confirm that the gait quality, including spatiotemporal variables and plantar pressure parameters, and symmetry index were lower in SCI patients compared with healthy subjects. Plantar pressure parameters and symmetry index could be sensitive quantitative parameters to improve gait quality of SCI patients. The protocols were approved by the Clinical Research Ethics Committee of Shengjing Hospital of China Medical University (approval No. 2015PS54J) on August 13, 2015. This trial was registered in the ISRCTN Registry (ISRCTN42544587) on August 22, 2018. Protocol version 1.0.
Collapse
|
32
|
Liu N, Yu R. Investigation of force, contact area and dwell time in finger-tapping tasks on membrane touch interface. ERGONOMICS 2018; 61:1519-1529. [PMID: 29856276 DOI: 10.1080/00140139.2018.1484178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 05/20/2018] [Indexed: 06/08/2023]
Abstract
This study aimed to determine the touch characteristics during tapping tasks on membrane touch interface and investigate the effects of posture and gender on touch characteristics variables. One hundred participants tapped digits displayed on a membrane touch interface on sitting and standing positions using all fingers of the dominant hand. Touch characteristics measures included average force, contact area and dwell time. Across fingers and postures, males exerted larger force and contact area than females, but similar dwell time. Across genders and postures, thumb exerted the largest force and the force of the other four fingers showed no significant difference. The contact area of the thumb was the largest, whereas that of the little finger was the smallest; the dwell time of the thumb was the longest, whereas that of the middle finger was the shortest. Relationships among finger sizes, gender, posture and touch characteristics were proposed. The findings helped direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Practitioner Summary: This study measured force, contact area and dwell time in tapping tasks on membrane touch interface and examined effects of gender and posture on force, contact area and dwell time. The findings will direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Abbreviations: M: mean; SD: standard deviation; ISO: International Organization for Standardization; LCD: liquid crystal display; ANOVA: analysis of variance; ANSI: American National Standards Institute; HFES: Human Factors and Ergonomics Society.
Collapse
|
33
|
Yang JH, Park HJ, Jang HD, Lee SJ. Measurement of cooked rice stickiness with consideration of contact area in compression test. J Texture Stud 2018; 49:639-645. [PMID: 30264394 DOI: 10.1111/jtxs.12370] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 04/16/2018] [Accepted: 06/05/2018] [Indexed: 11/29/2022]
Abstract
The cooked rice stickiness is conventionally measured as the maximum detachment force required to separate the probe from the sample, after compression on the platform of a texture analyzer. A corrected stickiness (the measured stickiness force divided by the contact area) was newly created to avoid the deviation of stickiness influenced by the contact area varying with the rice sample's irregularity, regarding shape and size. The contact area could be estimated from the volume, density, and thickness of the samples. The compression force triggering the stickiness was also converted to the corrected compression force (the force divided by the contact area). Two varieties of rice (short-grain rice and glutinous rice) were cooked with different amount of water to prepare the samples with various stickiness levels. The contact area was mostly higher in the glutinous rice than short-grain rice. The contact area increased with the cooking water amount. Three parameters were compared such as the stickiness (the measured force), the primarily corrected stickiness (the corrected stickiness at a fixed value of compression force), and the secondarily corrected stickiness (the corrected stickiness at a fixed value of the corrected compression force). The difference between the rice samples was the most pronounced in the secondarily corrected stickiness. The correlation between the instrumental and sensorial stickiness was also the highest in the secondarily corrected stickiness. Conclusively, the new corrected parameters enhanced the sample discrimination capability and the agreement with the sensorial stickiness than the uncorrected stickiness. PRACTICAL APPLICATIONS: Stickiness is the important quality factor associated with cooked rice preferences. Instrumental stickiness is a detaching force of the preliminarily compressed rice grain by cylindrical probe of texture testing equipment. When it comes to a force measurement, the contact area is usually considered to convert the force to stress. But, for the samples like cooked rice grain, with smaller contact area than that of probe, the contact area is not easy to know because it is not simply the probe bottom area. So the contact area had not been employed to measure cooked rice stickiness. In this study, an established method was devised to figure out the contact area. The corrected stickiness by considering the contact area proved to be more accurate than the original stickiness through sensory evaluation.
Collapse
|
34
|
Hwang JT, Kim Y, Bachman DR, Shields MN, Berglund LJ, Fitzsimmons AT, Fitzsimmons JS, O'Driscoll SW. Axial load transmission through the elbow during forearm rotation. J Shoulder Elbow Surg 2018; 27:530-537. [PMID: 29290603 DOI: 10.1016/j.jse.2017.10.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Revised: 10/09/2017] [Accepted: 10/18/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Forearm rotation is closely associated with the axiorotational force transmission through the elbow joint. A technique has been developed to study the transmission of force across the radiocapitellar and ulnotrochlear joints during forearm rotation. METHODS Ten human cadaveric upper limbs were prepared on a custom-designed apparatus that permits the application of extrinsic axial loads across an intact cadaveric elbow joint. A force-sensitive transducer was inserted into the elbow joint of each cadaver. A 160 N axial force was applied to the specimen during cyclic forearm rotation while the force, contact pressure, and contact area through the elbow joint were measured. RESULTS The mean force across the radiocapitellar joint showed no significant difference between pronation and supination (P = .3547). The radiocapitellar joint showed significantly higher contact area (P = .0001) and lower contact pressure (P = .0001) in pronation than in supination. The mean values for contact pressure, area, and force across the ulnotrochlear joint were not significantly different between supination and pronation. CONCLUSION The contact pressure and contact area of the radiocapitellar joint in the cadaveric model changed according to forearm rotation while the force remained constant. The mean contact pressure of the radiocapitellar joint in pronation was significantly lower than that in supination because the force across it did not change significantly and its contact area decreased significantly. These findings may suggest that the pronated elbow can play an important role in protecting the radiocapitellar joint in high-impact activities like delivering punch in martial arts or falling on an outstretched arm.
Collapse
|
35
|
Kong X, Zhu W, Cao L, Peng Y, Shen S, Deng Y. Controllable Electrical Contact Resistance between Cu and Oriented-Bi 2Te 3 Film via Interface Tuning. ACS APPLIED MATERIALS & INTERFACES 2017; 9:25606-25614. [PMID: 28691488 DOI: 10.1021/acsami.7b05460] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The contact resistance between metals and semiconductors has become critical for the design of thin-film thermoelectric devices with their continuous miniaturization. Herein, we report a novel interface tuning method to regulate the contact resistance at the Bi2Te3-Cu interface, and three Bi2Te3 films with different oriented microstructures are obtained. The lowest contact resistivity (∼10-7 Ω cm2) is observed between highly (00l) oriented Bi2Te3 and Cu film, nearly an order of magnitude lower than other orientations. This significant decrease of contact resistivity is attributed to the denser film connections, lower lattice misfit, larger effective conducting contact area, and smaller width of the surface depletion region. Meanwhile, our results show that the reduction of contact resistance has little dependence on the interfacial diffusion based on the little change in contact resistivity after the introduction of an effective Ti barrier layer. Our work provides a new idea for the mitigation of contact resistivity in thin-film thermoelectric devices and also gives certain guidance for the size design of the next-level miniaturized devices.
Collapse
|
36
|
Lee SM, Oh S, Yu SJ, Lee KM, Son SA, Kwon YH, Kim YI. Association between brain lateralization and mixing ability of chewing side. J Dent Sci 2017; 12:133-138. [PMID: 30895038 PMCID: PMC6395226 DOI: 10.1016/j.jds.2016.09.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Revised: 09/18/2016] [Indexed: 11/30/2022] Open
Abstract
Background/purpose Previous studies have suggested that functional dominance in one part of the body can be correlated with functional dominance in another part. Thus, the present research aimed to determine whether brain laterality (handedness, footedness, earedness, and eyedness) was related to mixing ability and chewing side preference. Materials and methods Fifty-four volunteers who were not undergoing any form of dental treatment took part in this study. Self-defined brain laterality was determined through a questionnaire. The volunteers performed five tasks related to brain laterality, which was identified by the side used to perform three or more of the five tasks. Chewing side preference was determined by observing the main gum location on the occlusal area when volunteers chewed for 30 strokes. Mixing Ability Index (MAI) was measured by analyzing the degree of mixing of two differently colored waxes (height, 3 mm; diameter, 20 mm). Occlusion contact area was measured by taking the maximum intercuspation bite with polysiloxane. Results Thirty-nine volunteers (72%) showed significant agreement between brain dominance and chewing preference side. The association between brain dominance and MAI was not significant. The occlusal contact area of the dominant side (mean = 48.2 mm2) was significantly wider than that of the nondominant side (25.7 mm2). Conclusion Brain laterality can be explained by the side of functional (preference of the hands, eyes, ears, and feet, and survey) has a positive correlation with chewing preference side. MAI between the brain dominant and nondominant sides was not significant. This shows that mastication efficiency does not differ between dominant and nondominant sides. So, this study suggests that brain dominance is correlated with chewing preference, but it does not affect efficiency of mastication.
Collapse
|
37
|
Liu X, Carré MJ, Zhang Q, Lu Z, Matcher SJ, Lewis R. Measuring contact area in a sliding human finger-pad contact. Skin Res Technol 2017; 24:31-44. [PMID: 28573767 DOI: 10.1111/srt.12387] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/26/2017] [Indexed: 11/26/2022]
Abstract
BACKGROUND/PURPOSE The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. METHODS Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). RESULTS In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. CONCLUSIONS The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction.
Collapse
|
38
|
Lv H, Guo Y, Wu G, Ji G, Zhao Y, Xu ZJ. Interface Polarization Strategy to Solve Electromagnetic Wave Interference Issue. ACS APPLIED MATERIALS & INTERFACES 2017; 9:5660-5668. [PMID: 28116900 DOI: 10.1021/acsami.6b16223] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Design of an interface to arouse interface polarization is an efficient route to attenuate high-frequency electromagnetic waves. The attenuation intensity is highly related to the contact area. To achieve stronger interface polarization, growing metal oxide granular film on graphene with a larger surface area seems to be an efficient strategy due to the high charge carrier concentration of graphene. This study is devoted to fabricating the filmlike composite by a facile thermal decomposition method and investigating the relationship among contact area, polarization intensity, and the type of metal oxide. Because of the high-frequency polarization effect, the composites presented excellent electromagnetic wave attenuation ability. It is shown that the optimal effective frequency bandwidth of graphene/metal oxide was close to 7.0 GHz at a thin coating layer of 2.0 mm. The corresponding reflection loss value was nearly -22.1 dB. Considering the attenuation mechanism, interface polarization may play a key role in the microwave-absorbing ability.
Collapse
|
39
|
Flessner MF. Pharmacokinetic problems in peritoneal drug administration: an update after 20 years. Pleura Peritoneum 2016; 1:183-191. [PMID: 30911622 DOI: 10.1515/pp-2016-0022] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Accepted: 11/29/2016] [Indexed: 12/14/2022] Open
Abstract
Intraperitoneal chemotherapy has demonstrated significant pharmacologic and clinical advantage over traditional intravenous administration for cancers that are restricted to the peritoneal cavity. The combination of cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (HIPEC) has become the standard technique used to fight ovarian and gastrointestinal cancers in many centers. However, challenges remain for HIPEC to contact the entire peritoneal surface, penetrate the tumor tissue, and transport to the lymphatics and other metastatic sites. New innovations in delivery technique, such as heated aerosol, and in delivery molecules, such as microparticles, nanoparticles, nanogels, and tumor-penetrating peptides are being tested in animal models and will likely soon be in human trials. Improvements in overall care, such as the recent clinical trial of an oral agent for maintenance therapy in ovarian carcinoma, will continue in this field for the next 20 years.
Collapse
|
40
|
Hamid KS, Scott AT, Nwachukwu BU, Danelson KA. The Role of Fluid Dynamics in Distributing Ankle Stresses in Anatomic and Injured States. Foot Ankle Int 2016; 37:1343-1349. [PMID: 27530984 DOI: 10.1177/1071100716660823] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND In 1976, Ramsey and Hamilton published a landmark cadaveric study demonstrating a dramatic 42% decrease in tibiotalar contact area with only 1 mm of lateral talar shift. An increase in maximum principal stress of at least 72% is predicted based on these findings though the delayed development of arthritis in minimally misaligned ankles does not appear to be commensurate with the results found in dry cadaveric models. We hypothesized that synovial fluid could be a previously unrecognized factor that contributes significantly to stress distribution in the tibiotalar joint in anatomic and injured states. METHODS As it is not possible to directly measure contact stresses with and without fluid in a cadaveric model, finite element analysis (FEA) was employed for this study. FEA is a modeling technique used to calculate stresses in complex geometric structures by dividing them into small, simple components called elements. Four test configurations were investigated using a finite element model (FEM): baseline ankle alignment, 1 mm laterally translated talus and fibula, and the previous 2 bone orientations with fluid added. The FEM selected for this study was the Global Human Body Models Consortium-owned GHBMC model, M50 version 4.2, a model of an average-sized male (distributed by Elemance, LLC, Winston-Salem, NC). The ankle was loaded at the proximal tibia with a distributed load equal to the GHBMC body weight, and the maximum principal stress was computed. RESULTS All numerical simulations were stable and completed with no errors. In the baseline anatomic configuration, the addition of fluid between the tibia, fibula, and talus reduced the maximum principal stress computed in the distal tibia at maximum load from 31.3 N/mm2 to 11.5 N/mm2. Following 1 mm lateral translation of the talus and fibula, there was a modest 30% increase in the maximum stress in fluid cases. Qualitatively, translation created less high stress locations on the tibial plafond when fluid was incorporated into the model. CONCLUSIONS The findings in this study demonstrate a meaningful role for synovial fluid in distributing stresses within the ankle that has not been considered in historical dry cadaveric studies. The increase in maximum stress predicted by simulation of an ankle with fluid was less than half that projected by cadaveric data, indicating a protective effect of fluid in the injured state. The trends demonstrated by these simulations suggest that bony alignment and fluid in the ankle joint change loading patterns on the tibia and should be accounted for in future experiments. CLINICAL RELEVANCE Synovial fluid may play a protective role in ankle injuries, thus delaying the onset of arthritis. Reactive joint effusions may also function to additionally redistribute stresses with higher volumes of viscous fluid.
Collapse
|
41
|
Brown MJ, Farrell JP, Kluczynski MA, Marzo JM. Biomechanical Effects of a Horizontal Medial Meniscal Tear and Subsequent Leaflet Resection. Am J Sports Med 2016; 44:850-4. [PMID: 26818450 DOI: 10.1177/0363546515623782] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Horizontal, degenerative tears of the medial meniscus and subsequent meniscectomy can compromise the biomechanical function of the meniscus in load transmission and weightbearing, leading to the development of radiographic and symptomatic tibiofemoral arthritis. HYPOTHESIS Resection of both leaflets of a horizontal medial meniscal tear will increase peak contact pressures and decrease contact areas in comparison with resection of only the inferior leaflet. STUDY DESIGN Controlled laboratory study. METHODS Twelve fresh-frozen human cadaveric knees had tibiofemoral peak contact pressures and contact areas under an 1800-N axial load measured by Tekscan in the control state. A horizontal tear was created in the posterior horn of the medial meniscus, and the knees were retested. The knees were tested a third time after resection of the inferior leaflet (single leaflet) and a final time after resection of the superior leaflet (both leaflets). The Friedman test was used to test for group differences in peak pressure (psi) and contact area (mm(2)) between test conditions (native, tear, inferior leaflet resection, and resection of both leaflets). RESULTS For the medial compartment, there was a statistically significant difference in peak pressure (P = .03) but not in contact area (P = .70) between testing conditions. Median peak pressure in the medial compartment was significantly greater for resection of both leaflets compared with the tear (406.5 vs 294.7 psi, respectively; P = .002). Median contact area in the medial compartment was greatest for resection of both leaflets (602.7 mm(2)), but there were no statistically significant differences between test conditions (P = .70). For the lateral compartment, there were no statistically significant differences in peak pressure (P = .99) or contact area (P = .77) between test conditions. CONCLUSION Resection of a single inferior leaflet after a horizontal medial meniscal tear preserves much of the original biomechanical function of the meniscus. Resection of both leaflets leads to a significant increase in contact pressure dispersed over the same contact area, which results in an undesirable biomechanical environment. CLINICAL RELEVANCE Arthroscopic inferior leaflet resection is a viable option for providing symptomatic relief of horizontal medial meniscal tears and preserves the ability of the meniscus to absorb axial loading on the knee joint, theoretically decreasing the risk of subsequent osteoarthritis.
Collapse
|
42
|
Arno S, Bell CP, Uquillas C, Borukhov I, Walker PS. Tibiofemoral contact mechanics following a horizontal cleavage lesion in the posterior horn of the medial meniscus. J Orthop Res 2015; 33:584-90. [PMID: 25643633 DOI: 10.1002/jor.22809] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 11/19/2014] [Accepted: 12/13/2014] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to determine if a horizontal cleavage lesion (HCL) of the posterior horn of the medial meniscus would result in changes to tibiofemoral contact mechanics, as measured by peak contact pressure and contact area, which can lead to cartilage degeneration. To study this, 10 cadaveric knees were tested in a rig where forces were applied (500 N Compression, 100 N shear, 2.5 Nm Torque) and the knee dynamically flexed from -5° to 135°, as peak contact pressure and contact area were recorded. After testing of the intact knee, a horizontal cleavage lesion was created arthroscopically and testing repeated. The Wilcoxon signed-rank test was used to determine if there were differences in peak contact pressure and contact area between the intact knee and that with the HCL. A statistically significant increase in peak contact pressure of 13%, on average, and a decrease in contact area of 6%, on average, was noted following the HCL. This suggests that a horizontal cleavage lesion will result in small but statistically significant changes in tibiofemoral contact mechanics which may lead to cartilage degeneration.
Collapse
|
43
|
Bachman DR, Thaveepunsan S, Park S, Fitzsimmons JS, An KN, O'Driscoll SW. The effect of prosthetic radial head geometry on the distribution and magnitude of radiocapitellar joint contact pressures. J Hand Surg Am 2015; 40:281-8. [PMID: 25542439 DOI: 10.1016/j.jhsa.2014.11.005] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 11/04/2014] [Accepted: 11/04/2014] [Indexed: 02/02/2023]
Abstract
PURPOSE To determine if radiocapitellar contact pressures would be elevated with nonanatomical (circular) prostheses over those mimicking native anatomy and if such pressures would be related to the depth and contour of the articular dish and to the pattern of prosthetic articulation against the lateral trochlear ridge. METHODS Three commercially available circular radial head designs were compared with an anatomical radial head and 2 modified anatomical prototype radial head designs in 10 cadaveric specimens. Each prosthesis and specimen combination was loaded in neutral rotation and maximal extension with a custom testing apparatus while measuring contact areas and pressures using thin-film pressure sensors. RESULTS Anatomical radial head prototype 2 had similar radiocapitellar contact areas and mean pressures as the native radial head; all other designs showed significant decreases in contact area and increased mean pressures. Peak contact pressures were also measured and were significantly elevated with all prostheses tested. Anatomical designs are statistically more likely to mimic normal contact with the lateral trochlear ridge and its adjacent sulcus than circular prostheses. They are also significantly less likely to have contact pressures above the 5 MPa threshold that is thought to be harmful to cartilage. The depth of the articular dish had a significant effect on contact area and pressure. CONCLUSIONS Commercially available radial head prostheses demonstrated reduced radiocapitellar contact areas and elevated contact pressures during compressive loading. These were significantly greater with symmetrical circular prostheses than with asymmetrical elliptical designs. The prosthesis that best mimicked native contact behavior was the anatomical radial head prototype 2 owing to its design for articulating with the capitellum, the lateral trochlear ridge, and the sulcus between. CLINICAL RELEVANCE Because radial head prostheses have the potential to cause capitellar erosion or arthritic change, those with lower contact pressures may lead to fewer such complications.
Collapse
|
44
|
Chen YR, Wu YF, Tang JB, Giddins G. Contact areas of the scaphoid and lunate with the distal radius in neutral and extension: correlation of falling strategies and distal radial anatomy. J Hand Surg Eur Vol 2014; 39:379-83. [PMID: 24127465 DOI: 10.1177/1753193413507810] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The functional neutral of wrist movement is about 10° extension yet the distal radius has a volar tilt. This has not previously been explained. Assuming that the contact area between the carpus and the distal radius increased in wrist extension this would also help stabilize the carpus on the distal radius in positions where typically there is greater loading. To test this hypothesis we reconstructed three-dimensional structures of the carpal bones and distal radius using computed tomography scans of 13 normal wrists. The contact areas of the scaphoid with the distal radius were measured and were found progressively increased from flexion 20°, neutral, extension 20°, to extension 40°. The maximal increases in the contact area of the scaphoid and the distal radius was at full wrist extension. No significant changes in the contact areas of the lunate with the distal radius were found between the different positions. The contact characteristics provide greater stability to the carpus on the distal radius, and to help spread forces from impact to the wrist reducing the transmitted peak forces and thus the risk of distal radius and carpal injuries.
Collapse
|
45
|
Sahu D, Holmes DM, Fitzsimmons JS, Thoreson AR, Berglund LJ, An KN, O'Driscoll SW. Influence of radial head prosthetic design on radiocapitellar joint contact mechanics. J Shoulder Elbow Surg 2014; 23:456-62. [PMID: 24630544 DOI: 10.1016/j.jse.2013.11.028] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Revised: 11/14/2013] [Accepted: 11/22/2013] [Indexed: 02/01/2023]
Abstract
HYPOTHESIS Our aim was to test whether anatomically designed metallic radial head implants could better reproduce native radiocapitellar contact pressure and areas than nonanatomic implants. METHODS The distal humerus and proximal radius from 6 cadaveric upper extremities were serially tested in supination with 100 N of compression force at 4 angles of flexion (0°, 30°, 60°, and 90°). By use of a thin flexible pressure transducer, contact pressures and areas were measured for the native radial head, an anatomic implant, a nonanatomic circular monopolar implant, and a bipolar nonanatomic implant. The data (mean contact pressure and mean contact area) were modeled using a 2-factor repeated-measures analysis of variance with P ≤ .05 considered to be significant. RESULTS The mean contact areas for the prosthetic radial heads were significantly less than those seen with the intact radial heads at every angle tested (P < .01). The mean contact pressures increased significantly with all prosthetic radial head types as compared with the native head. The mean contact pressures increased by 29% with the anatomic prosthesis, 230% with the monopolar prosthesis, and 220% with the bipolar prosthesis. Peak pressures of more than 5 MPa were more commonly observed with both the monopolar and bipolar prostheses than with the anatomic or native radial heads. CONCLUSIONS The geometry of radial head implants strongly influences their contact characteristics. In a direct radius-to-capitellum axial loading experiment, an anatomically designed radial head prosthesis had lower and more evenly distributed contact pressures than the nonanatomic implants that were tested.
Collapse
|
46
|
Lei Z, Yang J, Zhuang Z. A novel algorithm for determining contact area between a respirator and a headform. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2014; 11:227-237. [PMID: 24579752 PMCID: PMC4747037 DOI: 10.1080/15459624.2013.858818] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P < 0.0001), and N95 FFR sizing systems influenced all contact area dimensions (P < 0.05) except the left and right chin regions. The medium headform produced the largest contact area, while the large and small headforms produced the smallest.
Collapse
|
47
|
Xia D, Esser L, Tang WK, Zhou F, Zhou Y, Yu L, Yu CA. Structural analysis of cytochrome bc1 complexes: implications to the mechanism of function. BIOCHIMICA ET BIOPHYSICA ACTA 2013; 1827:1278-94. [PMID: 23201476 PMCID: PMC3593749 DOI: 10.1016/j.bbabio.2012.11.008] [Citation(s) in RCA: 119] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2012] [Revised: 11/13/2012] [Accepted: 11/19/2012] [Indexed: 01/18/2023]
Abstract
The cytochrome bc1 complex (bc1) is the mid-segment of the cellular respiratory chain of mitochondria and many aerobic prokaryotic organisms; it is also part of the photosynthetic apparatus of non-oxygenic purple bacteria. The bc1 complex catalyzes the reaction of transferring electrons from the low potential substrate ubiquinol to high potential cytochrome c. Concomitantly, bc1 translocates protons across the membrane, contributing to the proton-motive force essential for a variety of cellular activities such as ATP synthesis. Structural investigations of bc1 have been exceedingly successful, yielding atomic resolution structures of bc1 from various organisms and trapped in different reaction intermediates. These structures have confirmed and unified results of decades of experiments and have contributed to our understanding of the mechanism of bc1 functions as well as its inactivation by respiratory inhibitors. This article is part of a Special Issue entitled: Respiratory complex III and related bc complexes.
Collapse
|
48
|
McWalter EJ, O'Kane CM, Fitzpatrick DP, Wilson DR. Validation of an MRI-based method to assess patellofemoral joint contact areas in loaded knee flexion in vivo. J Magn Reson Imaging 2013; 39:978-87. [PMID: 24006182 DOI: 10.1002/jmri.24240] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2012] [Accepted: 05/01/2013] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To develop and validate short axial and sagittal MRI scans (<1min) to assess in vivo patellofemoral contact areas in loaded knee flexion. MATERIALS AND METHODS Contact area was assessed in four cadaver knee specimens from axial and sagittal scans using two contact area extraction techniques (delineation and intersection) and three calculation techniques (slice thickness multiplication, linear interpolation, and spline interpolation). Error was expressed as the mean absolute and percentage difference from a dye staining-based reference standard. Intrareader and intrasubject repeatability, expressed as the mean standard deviation, was determined. RESULTS Contact area assessments from the sagittal MRI scans using the delineation and slice thickness multiplication technique had the smallest error (47.7 ± 38.1 mm(2) or 10.7%). The intrareader repeatability from assessments using the sagittal scans was smaller than those using the axial scans when the delineation method was used (<9.4 ± 4.3 mm(2) and <15.4 ± 14.1 mm(2) , respectively). The intrasubject repeatability of the assessment from the sagittal scan was less than 39.9 ± 23.0 mm(2) . CONCLUSION This protocol yields assessments of contact area in less than 1 minute that have errors similar to those made using scans many times longer and can be used in series with kinematic scans to carry out simultaneous assessments in vivo to study patellofemoral joint disease.
Collapse
|
49
|
Atalay O, Kennon WR, Husain MD. Textile-based weft knitted strain sensors: effect of fabric parameters on sensor properties. SENSORS 2013; 13:11114-27. [PMID: 23966199 PMCID: PMC3812645 DOI: 10.3390/s130811114] [Citation(s) in RCA: 110] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2013] [Revised: 08/15/2013] [Accepted: 08/16/2013] [Indexed: 12/04/2022]
Abstract
The design and development of textile-based strain sensors has been a focus of research and many investigators have studied this subject. This paper presents a new textile-based strain sensor design and shows the effect of base fabric parameters on its sensing properties. Sensing fabric could be used to measure articulations of the human body in the real environment. The strain sensing fabric was produced by using electronic flat-bed knitting technology; the base fabric was produced with elastomeric yarns in an interlock arrangement and a conductive yarn was embedded in this substrate to create a series of single loop structures. Experimental results show that there is a strong relationship between base fabric parameters and sensor properties.
Collapse
|
50
|
Schneider T, Dabirrahmani D, Gillies RM, Appleyard RC. Biomechanical comparison of metatarsal head designs in first metatarsophalangeal joint arthroplasty. Foot Ankle Int 2013; 34:881-9. [PMID: 23509016 DOI: 10.1177/1071100713483096] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Arthritis of the metatarsophalangeal (MTP) joint is characterized by loss of MTP joint range of motion (ROM) and pain. Joint arthroplasty is one treatment option, and while results can be satisfactory, there is still room for improvement. The aim was to use cadaveric model to compare the sagittal kinematics and articulating contact properties of 4 different first metatarsal head designs of an MTP joint implant. METHODS Six cadaveric feet were each prepared with a single modular first MTP joint total arthroplasty. A standard cyclic load, which induced hallux dorsiflexion, was applied and motion measured from high resolution images. Contact behavior was collected simultaneously using a pressure transducer. Data collected compared the native joint with 4 different reconstructed cases. Each reconstructed joint used a different metatarsal-head-component while reusing the same phalangeal component to compare the 4 alternative metatarsal head designs. RESULTS All reconstructed joints displayed greater ROM compared with the intact joint. Of the 4 metatarsal head components, the grooved, anatomical design demonstrated the greatest dorsiflexion when compared to the standard design, 31.6 degrees (SD ± 8.6 degrees), P < .05. All reconstructed joints displayed contact areas lower than the intact (~50%, P < .001). The grooved metatarsal-head-component experienced the least contact force (P < .015), and the eccentric component underwent the greatest contact pressure (P < .05) when compared to the intact case. CONCLUSIONS In this study of a first metatarsophalangeal joint replacement design, ROM was shown to be better for the more anatomically designed metatarsal head, while contact properties did not vary across different designs. CLINICAL RELEVANCE This information may be useful in the development of new metatarsal components.
Collapse
|