26
|
Votino C, Cos T, Abu-Rustum R, Dahman Saidi S, Gallo V, Dobrescu O, Dessy H, Jani J. Use of spatiotemporal image correlation at 11-14 weeks' gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2013; 42:669-678. [PMID: 23801593 DOI: 10.1002/uog.12548] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2012] [Revised: 06/08/2013] [Accepted: 06/14/2013] [Indexed: 06/02/2023]
Abstract
OBJECTIVE To assess prospectively the use of four-dimensional (4D) spatiotemporal image correlation (STIC) in the evaluation of the fetal heart at 11-14 weeks' gestation. METHODS The study involved offline analysis of 4D-STIC volumes of the fetal heart acquired at 11-14 weeks' gestation in a population at high risk for congenital heart disease (CHD). Regression analysis was used to investigate the effect of gestational age, maternal body mass index, quality of the 4D-STIC volume, use of a transvaginal vs transabdominal probe and use of color Doppler ultrasonography on the ability to visualize separately different heart structures. The accuracy in diagnosing CHD based on early fetal echocardiography (EFE) using 4D-STIC vs conventional two-dimensional (2D) ultrasound was also evaluated. RESULTS One hundred and thirty-nine fetuses with a total of 243 STIC volumes were included in this study. Regression analysis showed that the ability to visualize different heart structures was correlated with the quality of the acquired 4D-STIC volumes. Independently, the use of a transvaginal approach improved visualization of the four-chamber view, and the use of Doppler improved visualization of the outflow tracts, aortic arch and interventricular septum. Follow-up was available in 121 of the 139 fetuses, of which 27 had a confirmed CHD. A diagnosis based on EFE using 4D-STIC was possible in 130 (93.5%) of the 139 fetuses. Accuracy in diagnosing CHD using 4D-STIC was 88.7%, and the results of 45% of the cases were fully concordant with those of 2D ultrasound or the final follow-up diagnosis. EFE using 2D ultrasound was possible in all fetuses, and accuracy in diagnosing CHD was 94.2%. Five of the seven false-positive or false-negative cases were minor CHD. CONCLUSIONS In fetuses at 11-14 weeks' gestation, the heart can be evaluated offline using 4D-STIC in a large number of cases, and this evaluation is more successful the higher the quality of the acquired volume. 2D ultrasound remains superior to 4D-STIC at 11-14 weeks, unless volumes of good to high quality can be obtained.
Collapse
|
27
|
Tudorache S, Cara M, Iliescu DG, Novac L, Cernea N. First trimester two- and four-dimensional cardiac scan: intra- and interobserver agreement, comparison between methods and benefits of color Doppler technique. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2013; 42:659-668. [PMID: 23494803 DOI: 10.1002/uog.12459] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 02/24/2013] [Accepted: 03/01/2013] [Indexed: 06/01/2023]
Abstract
OBJECTIVE To evaluate intra- and interobserver agreement for first-trimester fetal cardiac structural assessment, using two-dimensional (2D) ultrasound (2D-US) and 4D-US (4D spatiotemporal image correlation (STIC) technology), to compare the methods and to assess the advantages of adding color Doppler to each technique. METHODS Digital videoclips (B-mode and color Doppler) and 4D-STIC volumes (gray-scale and color Doppler) from 632 pregnancies with normal fetal hearts were acquired and stored at the time of detailed first-trimester ultrasound examination. Later analysis on a randomized sample of 100 cases was performed, targeting 11 cardiac structures and features. We compared visualization of fetal heart parameters using 2D-US vs 4D-US and gray-scale vs color Doppler imaging. RESULTS STIC volumes were considered satisfactory (adequate visualization of at least 8/11 parameters) in 78% of cases and 2D-US acquisitions in 89% of cases. The intra- and interobserver agreement was good for both 2D and 4D methods (kappa > 0.6), and the percentage overall agreement was very high using both methods (95%). 2D- and 4D-US identification of the fetal cardiac parameters did not differ significantly. The differences between gray-scale and color Doppler imaging were statistically significant in identifying similar key cardiac parameters, for both 2D- and 4D-US (P < 0.05). CONCLUSION Both 2D and 4D methods for assessing first-trimester heart parameters are feasible and repeatable within and between observers. Color Doppler adds valuable information to both methods.
Collapse
|
28
|
Sato M, Tsukimori K, Fujita Y, Morihana E, Fusazaki N, Takahata Y, Kado H. Prenatal diagnosis of coarctation of the aorta using 4-dimensional fetal echocardiography with power Doppler imaging and spatiotemporal image correlation. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2013; 32:719-721. [PMID: 23525400 DOI: 10.7863/jum.2013.32.4.719] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
|
29
|
Bataeva R, Bellsham-Revell H, Zidere V, Allan LD. Reliability of fetal thymus measurement in prediction of 22q11.2 deletion: a retrospective study using four-dimensional spatiotemporal image correlation volumes. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2013; 41:172-176. [PMID: 22605637 DOI: 10.1002/uog.11194] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/03/2012] [Indexed: 05/31/2023]
Abstract
OBJECTIVES To evaluate the thymic-thoracic ratio (TT-ratio) method in assessment of the fetal thymus in normal fetuses and in those with cardiac abnormalities, in the presence or absence of 22q11.2 deletion. METHOD Database records were reviewed for cases of conotruncal and arch abnormalities found on fetal echocardiography between January 2007 and September 2011. The 22q11.2 deletion status was retrieved and cases in which this was not known were excluded from the analysis, as were fetuses with aneuploidy or other genetic disorders. An additional 55 normal fetuses were analyzed as a control group. The TT-ratio was measured retrospectively using stored spatiotemporal image correlation (STIC) volume datasets. RESULTS Sixty-nine fetuses with relevant cardiac diagnoses were identified and, of these, 18 (26%) had 22q11.2 deletion. The mean gestational age at diagnosis was 22 weeks. Significant pairwise differences, but also overlap, were observed between all three groups (i.e. fetuses with heart defects with and without the 22q11.2 deletion and controls). The mean TT-ratio was 0.44 in our normal control group and was significantly smaller in fetuses with 22q11.2 deletion, corresponding to previously published data. However, the mean TT-ratio in the group with conotruncal anomalies but without the 22q11.2 deletion was also smaller than that in controls, in contrast to previously published data. The TT-ratio was above the normal mean, regardless of fetal karyotype, in all cases of interrupted aortic arch. CONCLUSION The TT-ratio method is a feasible and potentially useful tool during detailed fetal heart assessment. However, the absolute measurement is not reliable for prediction of 22q11.2 deletion and the obtained results should therefore be interpreted with caution. Fetal karyotyping should be recommended in cases with conotruncal heart abnormalities, irrespective of the TT-ratio.
Collapse
|
30
|
Wang N, Xie HN, Peng R, Zheng J, Zhu YX. Accuracy, agreement, and reliability of fetal cardiac measurements using 4-dimensional spatiotemporal image correlation. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:1719-1726. [PMID: 23091242 DOI: 10.7863/jum.2012.31.11.1719] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
OBJECTIVES The purpose of this study was to evaluate the accuracy, agreement, and reliability of 4-dimensional sonography using spatiotemporal image correlation (STIC) in fetal cardiac measurements during the second and third trimesters. METHODS Four-dimensional cardiac STIC volumes were acquired from 150 low-risk singleton pregnancies at gestational ages of 18 to 38 weeks. A total of 11 dimensions of the fetal heart and great vessels were analyzed by two different observers. Accuracy was assessed by comparing the measurements acquired by 4-dimensional STIC with those determined by 2-dimensional echocardiography by calculating the mean error and mean percent error and depicted by Bland-Altman plots. Absolute agreement and reliability of STIC-based measurements were evaluated on the basis of an intraclass correlation coefficient (ICC). RESULTS For STIC-based measurements of cardiac dimensions, good accuracy was achieved by the two experienced observers (mean percent error, -3.10% to 0.87% for observer A; -2.49% to -0.33% for observer B), and absolute agreement was almost perfect (ICC, 95% confidence interval, 0.916-0.993 for observer A; 0.957-0.990 for observer B). Interobserver ICCs among the two observers were between 0.909 and 0.990 (95% confidence interval), whereas intraobserver ICCs for observer A were between 0.894 and 0.989, and those for observer B were between 0.893 and 0.985, showing no significant differences in the reliability of SITC with regard to observers. CONCLUSIONS Four-dimensional sonography with STIC is a feasible and accurate method for fetal cardiac dimension measurements in the second and third trimesters. It is in good agreement with 2-dimensional echocardiography and can be performed by different observers.
Collapse
|
31
|
Zhang Y, Ding C, Fan M, Ren W, Guo Y, Sun W, Cai A. Evaluation of normal fetal pulmonary veins using B-flow imaging with spatiotemporal image correlation and by traditional color Doppler echocardiography. Prenat Diagn 2012; 32:1186-91. [PMID: 23044982 DOI: 10.1002/pd.3983] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE The purpose of our report is to evaluate the use of color Doppler echocardiography (CDE) with four chamber view (4CV), scanning around left atrium, and four-dimensional echocardiography with B-flow imaging and spatiotemporal image correlation (4D BF-STIC) in detecting fetal pulmonary veins at 17 to 40 weeks' gestation. METHODS This was a prospective study. Color Doppler echocardiography with 4CV, scanning around left atrium, and 4D BF-STIC were used to detect the pulmonary veins in 460 normal fetuses at 17 to 40 weeks of gestation. Routine prenatal screening was used to confirm that the fetuses were in good health with no cardiac or extra cardiac anomalies. All patients underwent follow up at one year. Twenty-two patients were excluded from the study. The number of pulmonary veins visualized using each method was recorded and then compared in six subgroups according to gestational age. RESULTS Four-dimensional echocardiography with B-flow imaging and spatiotemporal image correlation was the best method to detect the greatest number of pulmonary veins between 17 and 31 weeks of gestation. Scanning around left atrium detected more pulmonary veins than the traditional 4CV method throughout the gestational period. CONCLUSIONS The scanning around left atrium method proved to be the most suited for detecting pulmonary veins in clinical practice. 4D BF-STIC was superior in detecting the greatest number of pulmonary veins before 32 gestational weeks, but had limited clinical usage because it was very time-consuming and experience-dependent. The 4D method should be considered as a complement to traditional two-dimensional sonography, because it facilitates understanding of the anatomy and the spatial relationships of the cardiac structures.
Collapse
|
32
|
Peng R, Xie HN, Du L, Shi HJ, Zheng J, Zhu YX. Four-dimensional sonography with spatiotemporal image correlation and tomographic ultrasound imaging in the prenatal diagnosis of anomalous pulmonary venous connections. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:1651-1658. [PMID: 23011628 DOI: 10.7863/jum.2012.31.10.1651] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
OBJECTIVES To determine whether the use of 4-dimensional (4D) sonography with spatiotemporal image correlation (STIC) and tomographic ultrasound imaging (TUI) can provide additional information with respect to 2-dimensional (2D) echocardiography in the prenatal diagnosis of anomalous pulmonary venous connections. METHODS The study population consisted of 10 cases that were initially suspected to have total or partial anomalous pulmonary venous connections by prenatal 2D echocardiography between January 2008 and April 2011. All 10 cases were further examined and analyzed by 4D sonography with STIC-TUI. Detailed postnatal surgery or autopsy was performed on all 10 fetuses. RESULTS Total anomalous pulmonary venous connections were found in 5 cases, and a partial connection was diagnosed in 1 fetus postnatally. The remaining 4 cases were confirmed to have normal pulmonary venous connections. Four of the 5 fetuses with anomalous pulmonary venous connections had an additional major cardiac defect; 1 fetus had an isolated connection. Anomalous drainage was supracardiac to the superior vena cava in 2 cases, cardiac to the coronary sinus in 3, and partially infracardiac to the portal vein in remaining case. The pulmonary venous connections were completely and correctly visualized with 2D echocardiography in 2 of the 10 cases, partially identified in 4, and not distinguished completely in 4. Four-dimensional sonography imaging with STIC-TUI clearly visualized the connections in 9 of the 10 cases, and the remaining case was partially identified. CONCLUSIONS Four-dimensional sonography with STIC-TUI facilitates visualization of pulmonary venous connections, thus supplying additional information with respect to 2D echocardiography in the prenatal diagnosis of anomalous pulmonary venous connections.
Collapse
|
33
|
Gindes L, Matsui H, Achiron R, Mohun T, Ho SY, Gardiner H. Comparison of ex-vivo high-resolution episcopic microscopy with in-vivo four-dimensional high-resolution transvaginal sonography of the first-trimester fetal heart. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2012; 39:196-202. [PMID: 21638368 DOI: 10.1002/uog.9068] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
OBJECTIVE To compare the capability of three-dimensional (3D) reconstructed images produced by high-resolution episcopic microscopy (HREM) with that of in-vivo four-dimensional high-resolution transvaginal sonography (4D-HRTVS) to discern morphological features of the first-trimester human fetal heart. METHODS This was a prospective study of fetal hearts between 9 and 14 weeks' gestation. For ex-vivo 3D analysis, 30 human fetal hearts (at 9 + 0 to 14 + 6 weeks) were retrieved from surgical terminations of pregnancy. The specimens were embedded in resin and episcopic ('block-face') imaging was used to obtain a digital volume dataset (HREM) using 3-micron slicing. 4D-HRTVS was performed in 28 separate pregnancies at 10 + 2 to 14 + 0 weeks using a Voluson E8 ultrasound machine with volumetric transvaginal RIC 6-12-MHz transducers. Heart volumes obtained by both methods were compared to assess their ability to demonstrate first-trimester cardiac morphology. Comparisons were made in the transverse and sagittal planes, and using volume rendering. RESULTS All hearts were structurally normal, although abdominal situs was not examined in the isolated hearts that underwent HREM. 4D-HRTVS demonstrated each of the complete five transverse cardiac views in 32-86% of cases. HREM showed four features unique to the first-trimester human heart: prominent atrial appendages, spiral ventricular arrangement, prominent coronary arteries and thickened arterial walls. 4D-HRTVS could demonstrate the first two, but ultrasound resolution was too poor to quantify wall thickness and demonstrate coronary arteries in the 3-5-mm diameter heart. CONCLUSIONS 4D-HRTVS showed limited morphological features of the first-trimester fetal heart compared with HREM. HREM provides a gold standard of ex-vivo imaging against which developments in ultrasound resolution could be compared.
Collapse
|
34
|
Adriaanse BME, Tromp CHN, Simpson JM, Van Mieghem T, Kist WJ, Kuik DJ, Oepkes D, Van Vugt JMG, Haak MC. Interobserver agreement in detailed prenatal diagnosis of congenital heart disease by telemedicine using four-dimensional ultrasound with spatiotemporal image correlation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2012; 39:203-209. [PMID: 21611994 DOI: 10.1002/uog.9059] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
OBJECTIVE To evaluate the clinical accuracy of four-dimensional (4D) echocardiography in the detailed prenatal diagnosis of congenital heart disease (CHD) in a telemedicine setting. METHODS Ten second-trimester spatiotemporal image correlation (STIC) volumes were sent to three observers in different tertiary care centers with expertise in 4D echocardiography. The 10 volumes were selected based on the type of diagnosis to cover a wide spectrum of CHD anomalies, and also included one normal fetal heart. Observers were asked to provide the diagnosis, the postprocessing modalities used and the time spent on examination, and to give a rating of the confidence for the diagnosis on a 5-point Likert scale. They were free to consult other colleagues, including pediatric cardiologists, but were blinded to the prenatal diagnosis and the neonatal outcome. A diagnostic scoring system was used to evaluate different aspects of the heart defects. The results were compared with neonatal echocardiography or postmortem findings ('gold standard'). RESULTS In two cases all observers correctly diagnosed all details of the volume datasets. The observer with the best performance reached perfect agreement in six cases and nearly perfect agreement in three. The volumes were most frequently studied by sectional planes and were analyzed in a median time of 11.0 (range, 2.5-30.0) min. The median confidence score was 4.0 (range, 1.0-5.0). CONCLUSIONS In a telemedicine setting using STIC volumes, fetal cardiac anomalies can be diagnosed correctly by an expert. However, details required for adequate counseling and planning of postnatal care may be missed. STIC by telemedicine is a promising modality, although not accurate enough for exclusive use in clinical decision making regarding treatment, prognosis or termination of pregnancy.
Collapse
|
35
|
Rizzo G, Pietrolucci M, Aiello E, Mammarella S, Bosi C, Arduini D. The role of three-dimensional ultrasound in the diagnosis of fetal congenital anomalies: a review. MINERVA GINECOLOGICA 2011; 63:401-10. [PMID: 21926949 DOI: pmid/21926949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The objective of this review was to establish whether three-dimensional (3D) and four dimensional (4D) ultrasonography adds diagnostic information to what is currently provided by two-dimensional (2D) ultrasound in the diagnosis of the most frequent fetal structural defects: congenital heart disease and central nervous system congenital anomalies. There are evidences suggesting that 3D ultrasound allows to reduce the operator dependency in the visualization of standard diagnostic planes, thus reducing the examination time require for the obstetric ultrasound examination, with minimal impact on the visualization quality of the anatomic landmarks. Furthermore, operators with minimal experience may record cardiac or brain volumes that can be successfully analyzed off-line locally or sent by internet to experts for remote review. As a consequence 3D ultrasonography promises to become the method of choice for diagnosis congenital structural defects.
Collapse
|
36
|
Traisrisilp K, Tongprasert F, Srisupundit K, Luewan S, Tongsong T. Reference ranges for the fetal cardiac circumference derived by cardio-spatiotemporal image correlation from 14 to 40 weeks' gestation. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2011; 30:1191-1196. [PMID: 21876089 DOI: 10.7863/jum.2011.30.9.1191] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVES The purpose of this study was to construct reference ranges for the fetal cardiac circumference derived from volume data sets obtained by cardio-spatiotemporal image correlation. METHODS A prospective descriptive study was conducted on normal singleton pregnancies with certain dates from 14 to 40 weeks' gestation. All underwent cardio-spatiotemporal image correlation to acquire volume data sets for subsequent analysis. Cardiac circumferences were measured offline in a multiplanar view with 4-dimensional imaging software. The reference ranges were constructed against gestational weeks and the biparietal diameter as independent variables, using regression models for both the mean and SD. RESULTS A total of 678 satisfactory volumes were analyzed. Normal reference ranges for predicting means and SDs of the fetal cardiac circumference were established based on best-fitted equations. The mean cardiac circumference (millimeters) was modeled as a function of gestational age (weeks) and biparietal diameter (centimeters) as follows: cardiac circumference = -53.11 + 6.56 × gestational age - 0.035 × gestational age(2) (SD = 0.67 + 0.18 × gestational age) and -17.60 + 17.68 × biparietal diameter (SD = 1.651 + 0.61 × biparietal diameter). Equations for z score calculation were also provided, and percentile charts for predicting the cardiac circumference at various points of gestational age and biparietal diameter were constructed. CONCLUSIONS Normal reference ranges and z scores for the fetal cardiac circumference have been provided. These normative data may be useful tools for assessment of fetal cardiac size, especially in cardiomegaly due to fetal anemia.
Collapse
|
37
|
Lee W, Griffin W, Wildes D, Buckley D, Topka T, Chodakauskas T, Langer M, Calisti S, Bergstøl S, Malacrida JP, Lanteri F, Maffre J, McDaniel B, Shivkumar K, Cummings J, Callans D, Silvestry F, Packer D. A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:1478-1491. [PMID: 21768032 DOI: 10.1109/tuffc.2011.1967] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We developed prototype real-time 3-D intracardiac echocardiography catheters with integrated micromotors, allowing internal oscillation of a low-profile 64-element, 6.2-MHz phased-array transducer in the elevation direction. Components were designed to facilitate rotation of the array, including a low-torque flexible transducer interconnect and miniature fixtures for the transducer and micromotor. The catheter tip prototypes were integrated with two-way deflectable 10-Fr catheters and used in in vivo animal testing at multiple facilities. The 4-D ICE catheters were capable of imaging a 90° azimuth by up to 180° elevation field of view. Volume rates ranged from 1 vol/sec (180° elevation) to approximately 10 vol/sec (60° elevation). We successfully imaged electrophysiology catheters, atrial septal puncture procedures, and detailed cardiac anatomy. The elevation oscillation enabled 3-D visualization of devices and anatomy, providing new clinical information and perspective not possible with current 2-D imaging catheters.
Collapse
|
38
|
Hamill N, Yeo L, Romero R, Hassan SS, Myers SA, Mittal P, Kusanovic JP, Balasubramaniam M, Chaiworapongsa T, Vaisbuch E, Espinoza J, Gotsch F, Goncalves LF, Lee W. Fetal cardiac ventricular volume, cardiac output, and ejection fraction determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis. Am J Obstet Gynecol 2011; 205:76.e1-10. [PMID: 21531373 PMCID: PMC3175283 DOI: 10.1016/j.ajog.2011.02.028] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2009] [Revised: 01/18/2011] [Accepted: 02/14/2011] [Indexed: 12/21/2022]
Abstract
OBJECTIVE The objective of this study was to quantify fetal cardiovascular parameters using spatiotemporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL). STUDY DESIGN A cross-sectional study was performed in normal pregnancies (19-42 weeks) to evaluate ventricular volume, stroke volume (SV), cardiac output (CO), and ejection fraction (EF). The CO was also expressed as a function of estimated fetal weight and biometric parameters. RESULTS The following results were found: (1) 184 STIC datasets; (2) with advancing gestation, ventricular volume, SV, CO, and adjusted CO increased, whereas EF decreased; (3) right ventricular (RV) volume was larger than the left ventricular (LV) volume in systole (0.50 vs 0.27 mL; P < .001) and diastole (1.20 vs 1.03 mL; P < .001); (4) there were no differences between the LV and RV in SV, CO, or adjusted CO; and (5) LV EF was greater than the RV EF (72.2 vs 62.4%; P < .001). CONCLUSION Normal fetal cardiovascular physiology is characterized by a larger RV volume and a greater LV EF, resulting in similar LV and RV SV and CO.
Collapse
|
39
|
Yeo L, Romero R, Jodicke C, Kim SK, Gonzalez JM, Oggè G, Lee W, Kusanovic JP, Vaisbuch E, Hassan SS. Simple targeted arterial rendering (STAR) technique: a novel and simple method to visualize the fetal cardiac outflow tracts. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 37:549-56. [PMID: 20878672 PMCID: PMC3037449 DOI: 10.1002/uog.8841] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 09/05/2010] [Indexed: 05/13/2023]
Abstract
OBJECTIVE To describe a novel and simple technique—simple targeted arterial rendering (STAR)—to visualize the fetal cardiac outflow tracts from dataset volumes obtained with spatiotemporal image correlation (STIC) and applying a new display technology (OmniView). METHODS We developed a technique to image the outflow tracts by drawing three dissecting lines through the four-chamber view of the heart contained in a STIC volume dataset. Each line generated the following plane: (a) Line 1: ventricular septum en face with both great vessels (pulmonary artery anterior to the aorta); (b) Line 2: pulmonary artery with continuation into the longitudinal view of the ductal arch; and (c) Line 3: long-axis view of the aorta arising from the left ventricle. The pattern formed by all three lines intersecting approximately through the crux of the heart resembles a star. The technique was then tested in 50 normal fetal hearts at 15.3–40.4 weeks' gestation. To determine whether the technique could identify planes that departed from the normal images, we tested the technique in four cases with proven congenital heart defects (ventricular septal defect (VSD), transposition of great vessels, tetralogy of Fallot and pulmonary atresia with intact ventricular septum). RESULTS The STAR technique was able to generate the intended planes in all 50 normal cases. In the abnormal cases, the STAR technique allowed identification of the VSD, demonstrated great vessel anomalies and displayed views that deviated from what was expected from the examination of normal hearts. CONCLUSIONS This novel and simple technique can be used to visualize the outflow tracts and ventricular septum en face in normal fetal hearts. Inability to obtain expected views or the appearance of abnormal views in the generated planes should raise the index of suspicion for congenital heart disease involving the great vessels and/or the ventricular septum. The STAR technique may simplify examination of the fetal heart and could reduce operator dependency.
Collapse
|
40
|
Yagel S, Cohen SM, Rosenak D, Messing B, Lipschuetz M, Shen O, Valsky DV. Added value of three-/four-dimensional ultrasound in offline analysis and diagnosis of congenital heart disease. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 37:432-437. [PMID: 21031348 DOI: 10.1002/uog.8867] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 10/19/2010] [Indexed: 05/30/2023]
Abstract
OBJECTIVE Many published studies have shown that application of three-dimensional (3D) and real-time 3D (4D) ultrasound modalities can improve certain aspects of fetal echocardiography, but have left open the question of whether these modalities improved the accuracy of prenatal detection of anatomical fetal cardiovascular malformations. We aimed to determine whether 3D/4D ultrasound improved diagnostic ability in cases of congenital heart disease (CHD). METHODS Women who attended for early- or midtrimester targeted organ scans had complete fetal echocardiography according to our five-planes protocol, as well as examination of the ductus venosus and longitudinal aortic arch planes, performed with 2D ultrasound combined with 2D color Doppler, spatiotemporal image correlation (STIC), STIC with color Doppler, and STIC with B-flow. Ultrasound data of cases of CHD were stored in a dedicated archive. Stored cases were anonymized and the list order was randomized. Stored 2D ultrasound cineloops and 4D ultrasound volumes were reviewed separately according to a standardized table of 23 specified structures on five required planes of visualization: the upper abdomen, four-chamber view, five-chamber view, pulmonary artery bifurcation view, and three vessels and trachea plane. Separate diagnoses were recorded and finally compared. Diagnoses were confirmed by pathological examination or neonatal echocardiography. RESULTS During the study period, 13 101 examinations were performed; 181 diagnoses of CHD were made. In 12 of these, 3D/4D ultrasound added to the accuracy of our diagnosis: one right aortic arch with anomalous branching; one transposition of the great arteries with pulmonary atresia diagnosed with tomographic ultrasound imaging (TUI); one segmental interrupted aortic arch diagnosed with TUI; one right ventricle aneurysm diagnosed with B-flow; two agenesis of ductus venosus to the coronary sinus diagnosed by multiplanar reconstruction (MPR) and B-flow; two total anomalous pulmonary venous connection diagnosed with MPR; and four ventricular septal defect (VSD) diagnosed with the aid of virtual planes. There were 12 missed diagnoses and no false-positive results. CONCLUSIONS 3D/4D ultrasound modalities may have advantages in some aspects of fetal cardiovascular evaluation, however, overall 3D/4D ultrasound modalities had added value in only about 6% of cases of fetal anatomical cardiovascular anomalies.
Collapse
|
41
|
Yeo L, Romero R, Jodicke C, Oggè G, Lee W, Kusanovic JP, Vaisbuch E, Hassan SS. Four-chamber view and 'swing technique' (FAST) echo: a novel and simple algorithm to visualize standard fetal echocardiographic planes. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 37:423-31. [PMID: 20878671 PMCID: PMC3037435 DOI: 10.1002/uog.8840] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 09/05/2010] [Indexed: 05/13/2023]
Abstract
OBJECTIVE To describe a novel and simple algorithm (four-chamber view and 'swing technique' (FAST) echo) for visualization of standard diagnostic planes of fetal echocardiography from dataset volumes obtained with spatiotemporal image correlation (STIC) and applying a new display technology (OmniView). METHODS We developed an algorithm to image standard fetal echocardiographic planes by drawing four dissecting lines through the longitudinal view of the ductal arch contained in a STIC volume dataset. Three of the lines are locked to provide simultaneous visualization of targeted planes, and the fourth line (unlocked) 'swings' through the ductal arch image (swing technique), providing an infinite number of cardiac planes in sequence. Each line generates the following plane(s): (a) Line 1: three-vessels and trachea view; (b) Line 2: five-chamber view and long-axis view of the aorta (obtained by rotation of the five-chamber view on the y-axis); (c) Line 3: four-chamber view; and (d) 'swing line': three-vessels and trachea view, five-chamber view and/or long-axis view of the aorta, four-chamber view and stomach. The algorithm was then tested in 50 normal hearts in fetuses at 15.3-40 weeks' gestation and visualization rates for cardiac diagnostic planes were calculated. To determine whether the algorithm could identify planes that departed from the normal images, we tested the algorithm in five cases with proven congenital heart defects. RESULTS In normal cases, the FAST echo algorithm (three locked lines and rotation of the five-chamber view on the y-axis) was able to generate the intended planes (longitudinal view of the ductal arch, pulmonary artery, three-vessels and trachea view, five-chamber view, long-axis view of the aorta, four-chamber view) individually in 100% of cases (except for the three-vessels and trachea view, which was seen in 98% (49/50)) and simultaneously in 98% (49/50). The swing technique was able to generate the three-vessels and trachea view, five-chamber view and/or long-axis view of the aorta, four-chamber view and stomach in 100% of normal cases. In the abnormal cases, the FAST echo algorithm demonstrated the cardiac defects and displayed views that deviated from what was expected from the examination of normal hearts. The swing technique was useful for demonstrating the specific diagnosis due to visualization of an infinite number of cardiac planes in sequence. CONCLUSIONS This novel and simple algorithm can be used to visualize standard fetal echocardiographic planes in normal fetal hearts. The FAST echo algorithm may simplify examination of the fetal heart and could reduce operator dependency. Using this algorithm, inability to obtain expected views or the appearance of abnormal views in the generated planes should raise the index of suspicion for congenital heart disease.
Collapse
|
42
|
Luewan S, Yanase Y, Tongprasert F, Srisupundit K, Tongsong T. Fetal cardiac dimensions at 14-40 weeks' gestation obtained using cardio-STIC-M. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 37:416-422. [PMID: 21305637 DOI: 10.1002/uog.8961] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
OBJECTIVES To establish normative reference ranges of fetal cardiac dimensions derived from volume datasets acquired using spatiotemporal image correlation with M-mode display (cardio-STIC-M). METHODS A cross-sectional study was undertaken on singleton pregnancies with normal fetuses and accurate gestational ages. Cardio-STIC volume datasets were acquired by experienced operators using a high-resolution ultrasound machine; these were maneuvered to obtain a four chamber-view with exactly horizontal interventricular septum (IVS). Cardiac dimensions were measured in STIC-M-mode using 4D View software. RESULTS A total of 657 measurements, at a rate of between 15 and 37 per week, were obtained. Normal reference ranges for biventricular outer diameter, left and right ventricular inner diameter, left and right ventricular wall thickness, IVS thickness, left to right ventricular diameter ratio and left and right ventricular shortening fractions were constructed based on best-fit equations as a function of gestational age, fetal head circumference and biparietal diameter. Thirty-four volume datasets of abnormal fetal hearts were also separately assessed, many of which showed abnormal cardiac dimensions. CONCLUSIONS This is the first report on normal ranges of fetal cardiac dimensions constructed using the new cardio-STIC-M technology. Preliminary evaluation suggests that these reference ranges may be a useful tool in the assessment of fetal cardiac abnormalities.
Collapse
|
43
|
Herberg U, Lück S, Steinweg B, Brand M, Knies R, Geipel A, Trier HG, Breuer J. Volumetry of fetal hearts using 3D real-time matrix echocardiography - in vitro validation experiments and 3D echocardiographic studies in fetuses. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2011; 32:46-53. [PMID: 20614413 DOI: 10.1055/s-0029-1245428] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
PURPOSE The aim of this study was to assess the feasibility, accuracy and reliability of 3D real-time echocardiography for fetal heart volumetry. MATERIALS AND METHODS Fifty unselected and consecutive fetuses, including 14 with cardiac malformations, were scanned prospectively using real-time 3D matrix technology and 2D echocardiography to determine ventricular volumes. Small phantoms as well as modified balloons (0.5 - 20 ml) were used to assess the validity of 2D and 3D distance, area and volume calculations and to study potential sources of error during data acquisition and analysis. The data was evaluated by two blinded observers. RESULTS In vitro, real-time 3D and 2D underestimated the actual volumes by -5.49 % (3D) and -6.86 % (2D). The intraobserver and interobserver variability were excellent. In vivo, real-time 3D was superior to 2D with regard to intraobserver and interobserver variability (mean coefficient of variation 8.28 % (3D) versus 13.96 % (2D), and mean intraclass correlation coefficient 0.997 (3D) versus 0.885 (2D) for left ventricular volumes). Similar to in vitro, in vivo 2D volumes were calculated smaller than 3D volumes (mean difference -0.39 to -0.94 ml). The ventricular volumes and stroke volumes increased exponentially with gestation. Secondary to poor imaging windows in advanced gestation or inadequate delineation of endocardial borders in small hearts at less than 19 weeks, 3D data could not be analyzed sufficiently in 6 / 50 fetuses. CONCLUSION Real-time 3D using a matrix transducer is a feasible, reliable and valid method for volume determination in the fetus beyond 19 weeks of gestation. If compared to 2D, real-time 3D echocardiography provides improved accuracy of cardiac volumetry, decreases intraobserver and interobserver variability and is a promising tool for the accurate assessment of cardiac size and function.
Collapse
|
44
|
Rizzo G, Capponi A, Pietrolucci ME, Capece G, Cimmino E, Colosi E, Ferrentino S, Sica C, Di Meglio A, Arduini D. Satisfactory rate of postprocessing visualization of standard fetal cardiac views from 4-dimensional cardiac volumes acquired during routine ultrasound practice by experienced sonographers in peripheral centers. JOURNAL OF ULTRASOUND IN MEDICINE 2011; 30:93-9. [PMID: 21193709 DOI: 10.7863/jum.2011.30.1.93] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The aim of this study was to evaluate the feasibility of visualizing standard cardiac views from 4-dimensional (4D) cardiac volumes obtained at ultrasound facilities with no specific experience in fetal echocardiography. Five sonographers prospectively recorded 4D cardiac volumes starting from the 4-chamber view on 500 consecutive pregnancies at 19 to 24 weeks' gestation undergoing routine ultrasound examinations (100 pregnancies for each sonographer). Volumes were sent to the referral center, and 2 independent reviewers with experience in 4D fetal echocardiography assessed their quality in the display of the abdominal view, 4-chamber view, left and right ventricular outflow tracts, and 3-vessel and trachea view. Cardiac volumes were acquired in 474 of 500 pregnancies (94.8%). The 2 reviewers respectively acknowledged the presence of satisfactory images in 92.4% and 93.6% of abdominal views, 91.5% and 93.0% of 4-chamber views, in 85.0% and 86.2% of left ventricular outflow tracts, 83.9% and 84.5% of right ventricular outflow tracts, and 85.2% and 84.5% of 3-vessel and trachea views. The presence of a maternal body mass index of greater than 30 altered the probability of achieving satisfactory cardiac views, whereas previous maternal lower abdominal surgery did not affect the quality of reconstructed cardiac views. In conclusion, cardiac volumes acquired by 4D sonography in peripheral centers showed high enough quality to allow satisfactory diagnostic cardiac views.
Collapse
|
45
|
Espinoza J, Lee W, Comstock C, Romero R, Yeo L, Rizzo G, Paladini D, Viñals F, Achiron R, Gindes L, Abuhamad A, Sinkovskaya E, Russell E, Yagel S. Collaborative study on 4-dimensional echocardiography for the diagnosis of fetal heart defects: the COFEHD study. JOURNAL OF ULTRASOUND IN MEDICINE 2010; 29:1573-80. [PMID: 20966468 DOI: 10.7863/jum.2010.29.11.1573] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE Congenital anomalies are the leading cause of infant mortality in the United States, and congenital heart defects (CHDs) are the most common type of birth defects. Recently, 4-dimensional ultrasonography (4DUS) with spatiotemporal image correlation (STIC) has been introduced for fetal echocardiography. Accumulating evidence indicates that 4DUS with STIC may facilitate the examination of the fetal heart. Our objectives were to determine the accuracy of 4DUS for the diagnosis of CHDs and the agreement among centers. METHODS This study included 7 centers with expertise in 4D fetal echocardiography. Fetuses with and without confirmed heart defects were scanned between 18 and 26 weeks, and their volume data sets were uploaded onto a centralized file transfer protocol server. Intercenter agreement was determined using a κ statistic for multiple raters. RESULTS Ninety volume data sets were randomly selected for blinded analysis. Overall, the median (range) sensitivity, specificity, positive and negative predictive values, and false-positive and -negative rates for the identification of fetuses with CHDs were 93% (77%-100%), 96% (84%-100%), 96% (83%-100%), 93% (79%-100%), 4.8% (2.7%-25%), and 6.8% (5%-22%), respectively. The most frequent CHDs were conotruncal anomalies (36%). There was excellent intercenter agreement (κ = 0.97). CONCLUSIONS (1) Four-dimensional volume data sets can be remotely acquired and accurately interpreted by different centers. (2) Among centers with technical expertise, 4DUS is an accurate and reliable method for fetal echocardiography.
Collapse
|
46
|
Bennasar M, Martínez JM, Gómez O, Bartrons J, Olivella A, Puerto B, Gratacós E. Accuracy of four-dimensional spatiotemporal image correlation echocardiography in the prenatal diagnosis of congenital heart defects. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 36:458-464. [PMID: 20549767 DOI: 10.1002/uog.7720] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
OBJECTIVE To evaluate the accuracy of four-dimensional (4D) spatiotemporal image correlation (STIC) echocardiography for the diagnosis of fetal congenital heart disease (CHD) in a selected high-risk population. METHODS Three hundred and sixty-three pregnant women referred for suspected CHD on screening ultrasound were evaluated by means of conventional echocardiography between 14 and 41 weeks' gestation and 4D-STIC volumes were obtained (including gray-scale and color Doppler information). Stored volumes were analyzed, at least 1 year after they had been acquired, by examiners blinded to the patients' identities and outcomes. The STIC diagnoses were compared to those made on conventional two-dimensional echocardiography and the accuracy of diagnosis was assessed with respect to postnatal examination, or autopsy in cases of termination of pregnancy or perinatal death. RESULTS The mean gestational age at volume acquisition was 24 + 5 weeks. STIC evaluation was possible in 98% of cases. Twenty-one cases were lost to follow-up, with a total of 167 normal hearts and 175 cases of CHD diagnosed at postnatal evaluation. The overall accuracy, sensitivity, specificity and positive and negative predictive values of STIC in determining the presence or absence of CHD were 91.6, 94.9, 88.1, 89.7 and 94.0%, respectively. Absolute concordance with the final specific diagnosis among cases with confirmed CHD was 74.3% for STIC echocardiography, compared with 81.7% for real-time evaluation. CONCLUSION 4D-STIC echocardiography performed by experienced operators can be used in fetuses at risk for cardiac anomalies in order to reliably provide reassurance of normality or to accurately diagnose major structural heart defects.
Collapse
|
47
|
Uittenbogaard LB, Haak MC, Tromp CHN, Terwee CB, Van Vugt JMG. Reliability of fetal cardiac volumetry using spatiotemporal image correlation: assessment of in-vivo and in-vitro measurements. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 36:308-314. [PMID: 20131339 DOI: 10.1002/uog.7582] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVE To assess the reliability of measurement of fetal cardiac ventricular volume, stroke volume, and ejection fraction with four-dimensional ultrasound using spatiotemporal image correlation (STIC). METHODS Volume datasets were collected from two sources: 24 from fetuses over a range of gestational ages and 12 from a miniature balloon model. Datasets were analyzed by three observers, repeatedly in 12 fetal datasets and all balloon datasets. Volume calculations were obtained by manually tracing multiple parallel slices (three-dimensional (3D) slice method). Measurement error was assessed by calculating standard errors of measurement (SEM) and coefficients of variation (CV). Reliability was assessed by calculating interobserver and intraobserver intraclass correlation coefficients (ICC). RESULTS Measurement errors of balloon volumes were small and reliability was good (SEM <or= 0.07 mL, ICC 0.98-1.00). Fetal ventricle volume measurement error ranged from 0.09 to 0.20 mL and CV from 14.6 to 28.3%. Ventricular volume reliabilities for intra- and interobserver comparisons were greater than or equal to 0.94 and 0.75, respectively. Fetal stroke volume measurement error (SEM 0.17 mL), CV (21.9%) and reliability were measured (intraobserver ICC: left ventricle stroke volume (LVSV), 0.93 vs. right ventricle stroke volume (RVSV), 0.88; interobserver ICC: LVSV, 0.75 vs. RVSV, 0.86). The measurement error decreased with increasing operator experience. The reliability of ejection fraction calculations was poor (ICC < 0.7) for intra- and interobserver comparisons. CONCLUSIONS Volume measurements obtained with STIC and 3D slice methods using a balloon model were reliable. In the fetus, measurement errors decreased with increasing operator experience, and reliability was better for stroke volume than for ejection fraction.
Collapse
|
48
|
Shen O, Yagel S. The added value of 3D/4D ultrasound imaging in fetal cardiology: has the promise been fulfilled? ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 35:260-262. [PMID: 20205202 DOI: 10.1002/uog.7569] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
49
|
Volpe P, Tuo G, De Robertis V, Campobasso G, Marasini M, Tempesta A, Gentile M, Rembouskos G. Fetal interrupted aortic arch: 2D-4D echocardiography, associations and outcome. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 35:302-309. [PMID: 20069674 DOI: 10.1002/uog.7530] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVES To analyze fetal two-dimensional (2D) echocardiographic characteristics of interrupted aortic arch (IAA) and its different types, to explore whether the use of 4D ultrasound with B-flow imaging and spatiotemporal image correlation (STIC) can improve prenatal diagnostic accuracy, and to describe associations and outcome. METHODS The study comprised IAA fetuses examined exclusively by 2D conventional echocardiography during the period from 1994 to 2003, and those identified by conventional echocardiography and examined further by 4D ultrasound with B-flow imaging and STIC during the period January 2004 to July 2008, identified among fetuses examined at two referral centers for congenital heart defects (CHD). Postnatal follow-up was available in all cases. Karyotyping and fluorescent in-situ hybridization (FISH) analysis for the DiGeorge critical region (22q11.2) were performed in all cases. RESULTS Twenty-two cases of isolated IAA (15 Type B and seven Type A, seven and three of which, respectively, underwent B-flow imaging and STIC) were detected among 2520 cases of fetal CHD. In seven of the 15 Type B cases, a right subclavian artery arose anomalously (ARSA). 2D echocardiography failed to distinguish the type of IAA in only two cases and the ARSA in five of the seven cases. B-flow imaging and STIC successfully identified IAA types in all 10 cases examined and clearly visualized the origin and course of the ARSA, including cervical ones. FISH detected 22q11.2 microdeletion in 10 of the 15 Type B cases and an unusual association with Type A in one of the seven cases. Fetal/neonatal outcome included: eight terminations of pregnancy, one intrauterine death and four postoperative deaths in the neonatal period, and nine neonates were alive after surgery at a mean follow-up time of 58 months (range, 4 months-13 years). CONCLUSION Our results confirm the feasibility of prenatal characterization of IAA and its different types based on 2D echocardiographic examination, albeit with some limitations in the thorough assessment. 4D ultrasound with B-flow imaging and STIC can apparently facilitate visualization and detailed examination of the anatomical features of the IAA types, including visualization of the neck vessels, thus supplying additional information with respect to 2D sonography. As for the known association with microdeletion 22q11.2, our data indicate that Types A and B are distinct, there being a close association only with IAA Type B.
Collapse
|
50
|
Bennasar M, Martínez JM, Gómez O, Figueras F, Olivella A, Puerto B, Gratacós E. Intra- and interobserver repeatability of fetal cardiac examination using four-dimensional spatiotemporal image correlation in each trimester of pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 35:318-323. [PMID: 20127758 DOI: 10.1002/uog.7570] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVE To assess the intra- and interobserver repeatability of the evaluation of fetal cardiac structures and measurements using spatiotemporal image correlation (STIC) technology in each trimester of pregnancy. METHODS Four-dimensional (4D)-STIC volumes from 150 low-risk pregnancies were acquired at first-, second- or third-trimester scan for later analysis by two different reviewers. A total of 19 items, including the evaluation of 14 structures as well as five measurements of the fetal heart, were evaluated. The reliability of qualitative variables was evaluated using Cohen's kappa and absolute agreement analysis while that of quantitative parameters was assessed using the intraclass correlation coefficient (ICC). RESULTS Forty-five, 47 and 47 STIC volumes were included in the final analysis from the first, second and third trimesters, respectively. For the evaluation of cardiac structures, good or excellent intra- and interobserver agreement (kappa > 0.6) was obtained in 12/14 and 9/14, respectively, while absolute agreement was > 90% for most structures evaluated. Regarding the quantitative cardiac measurements, ICC values were above 0.90 for all but cardiac axis (intraobserver ICC, 0.81 and interobserver ICC, 0.61). There were no significant differences in the repeatability values observed for qualitative or quantitative parameters among the trimesters of pregnancy. CONCLUSION Cardiac examination from 4D-STIC volumes showed a high repeatability between and within observers in each trimester of pregnancy.
Collapse
|