26
|
Zhang D, Luo T, Cai X, Zhao NN, Zhang CY. Recent advances in nucleic acid signal amplification-based aptasensors for sensing mycotoxins. Chem Commun (Camb) 2024; 60:4745-4764. [PMID: 38647208 DOI: 10.1039/d4cc00982g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Mycotoxin contamination in food products may cause serious health hazards and economic losses. The effective control and accurate detection of mycotoxins have become a global concern. Even though a variety of methods have been developed for mycotoxin detection, most conventional methods suffer from complicated operation procedures, low sensitivity, high cost, and long assay time. Therefore, the development of simple and sensitive methods for mycotoxin assay is highly needed. The introduction of nucleic acid signal amplification technology (NASAT) into aptasensors significantly improves the sensitivity and facilitates the detection of mycotoxins. Herein, we give a comprehensive review of the recent advances in NASAT-based aptasensors for assaying mycotoxins and summarize the principles, features, and applications of NASAT-based aptasensors. Moreover, we highlight the challenges and prospects in the field, including the simultaneous detection of multiple mycotoxins and the development of portable devices for field detection.
Collapse
|
27
|
Yu J, Yu C, Li Y, Yu C, Wang Y, Wu R, Li B. The single strand template shortening strategy improves the sensitivity and specificity of solid-state nanopore detection. Chem Commun (Camb) 2024; 60:4723-4726. [PMID: 38597243 DOI: 10.1039/d4cc00961d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Through controlling the ssDNA product length of rolling circle amplification with AcyNTP, here we develop a nanopore signal enhancement strategy (STSS), which can successfully transfer the short oligonucleotide targets into long ssDNAs with appropriate lengths that can generate significant translocation currents. By labelling the RCA product with tags such as tetrahedral structures and isothermal amplicons, the resolution, signal specificity, and target range of the STSS can be further extended.
Collapse
|
28
|
Xu J, Yang H, Sui Z, Yuan X, Jia L, Guo L. One-pot isothermal amplification permits recycled activation of CRISPR/Cas12a for sensing terminal deoxynucleotidyl transferase activity. Chem Commun (Camb) 2024; 60:4683-4686. [PMID: 38591968 DOI: 10.1039/d4cc00825a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
This study introduces a one-pot isothermal amplification assay for ultrasensitive analysis of terminal deoxynucleotidyl transferase (TdT) activity. The system realizes recycled activation of CRISPR/Cas12a, enabling exceptional signal amplification. This approach maximizes the simplicity of the detection method, offering a promising avenue for molecular disease diagnosis.
Collapse
|
29
|
Cohen JF, Tanz RR, Shulman ST. Group A Streptococcus pharyngitis in Children: New Perspectives on Rapid Diagnostic Testing and Antimicrobial Stewardship. J Pediatric Infect Dis Soc 2024; 13:250-256. [PMID: 38456797 DOI: 10.1093/jpids/piae022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 03/06/2024] [Indexed: 03/09/2024]
Abstract
The most common cause of bacterial pharyngitis is Group A Streptococcus (GAS). Accurate diagnosis of GAS pharyngitis is crucial to identify children who would benefit from antibiotic treatment. Rapid diagnosis has the potential to reduce antibiotic overuse. Current national guidelines differ in their recommendations for GAS testing. While rapid antigen detection tests (RADTs) are widely used, their sensitivity is considered too low for stand-alone testing by several expert bodies. Newer molecular tests using nucleic acid amplification show higher accuracy and fast results, but their cost, complexity, and very high sensitivity may limit widespread adoption. This review provides up-to-date evidence regarding rapid diagnostic testing and antimicrobial stewardship in children with sore throat. We discuss discrepancies across GAS testing guidelines at the international level, patient selection for testing for GAS, rapid test accuracy, and the potential role of rapid GAS tests to promote antibiotic stewardship, with emphasis on emerging rapid molecular tests.
Collapse
|
30
|
Xiang X, Ren X, Wen Q, Xing G, Liu Y, Xu X, Wei Y, Ji Y, Liu T, Song H, Zhang S, Shang Y, Song M. Automatic Microfluidic Harmonized RAA-CRISPR Diagnostic System for Rapid and Accurate Identification of Bacterial Respiratory Tract Infections. Anal Chem 2024; 96:6282-6291. [PMID: 38595038 DOI: 10.1021/acs.analchem.3c05682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Respiratory tract infections (RTIs) pose a grave threat to human health, with bacterial pathogens being the primary culprits behind severe illness and mortality. In response to the pressing issue, we developed a centrifugal microfluidic chip integrated with a recombinase-aided amplification (RAA)-clustered regularly interspaced short palindromic repeats (CRISPR) system to achieve rapid detection of respiratory pathogens. The limitations of conventional two-step CRISPR-mediated systems were effectively addressed by employing the all-in-one RAA-CRISPR detection method, thereby enhancing the accuracy and sensitivity of bacterial detection. Moreover, the integration of a centrifugal microfluidic chip led to reduced sample consumption and significantly improved the detection throughput, enabling the simultaneous detection of multiple respiratory pathogens. Furthermore, the incorporation of Chelex-100 in the sample pretreatment enabled a sample-to-answer capability. This pivotal addition facilitated the deployment of the system in real clinical sample testing, enabling the accurate detection of 12 common respiratory bacteria within a set of 60 clinical samples. The system offers rapid and reliable results that are crucial for clinical diagnosis, enabling healthcare professionals to administer timely and accurate treatment interventions to patients.
Collapse
|
31
|
Yang J, Xu Z, Yu L, Wang B, Hu R, Tang J, Lv J, Xiao H, Tan X, Wang G, Li JX, Liu Y, Shao PL, Zhang B. Organic Fluorophores with Large Stokes Shift for the Visualization of Rapid Protein and Nucleic Acid Assays. Angew Chem Int Ed Engl 2024; 63:e202318800. [PMID: 38443316 DOI: 10.1002/anie.202318800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 03/05/2024] [Accepted: 03/05/2024] [Indexed: 03/07/2024]
Abstract
Organic small-molecule fluorophores, characterized by flexible chemical structure and adjustable optical performance, have shown tremendous potential in biosensing. However, classical organic fluorophore motifs feature large overlap between excitation and emission spectra, leading to the requirement of advanced optical set up to filter desired signal, which limits their application in scenarios with simple settings. Here, a series of wavelength-tunable small-molecule fluorescent dyes (PTs) bearing simple organic moieties have been developed, which exhibit Stokes shift up to 262 nm, molar extinction coefficients ranged 30,000-100,000 M-1 cm-1, with quantum yields up to 54.8 %. Furthermore, these dyes were formulated into fluorescent nanoparticles (PT-NPs), and applied in lateral flow assay (LFA). Consequently, limit of detection for SARS-CoV-2 nucleocapsid protein reached 20 fM with naked eye, a 100-fold improvement in sensitivity compared to the pM detection level for colloidal gold-based LFA. Besides, combined with loop-mediated isothermal amplification (LAMP), the LFA system achieved the visualization of single copy level nucleic acid detection for monkeypox (Mpox).
Collapse
|
32
|
Wang Y, Chen H, Lin K, Han Y, Gu Z, Wei H, Mu K, Wang D, Liu L, Jin R, Song R, Rong Z, Wang S. Ultrasensitive single-step CRISPR detection of monkeypox virus in minutes with a vest-pocket diagnostic device. Nat Commun 2024; 15:3279. [PMID: 38627378 PMCID: PMC11021474 DOI: 10.1038/s41467-024-47518-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 04/03/2024] [Indexed: 04/19/2024] Open
Abstract
The emerging monkeypox virus (MPXV) has raised global health concern, thereby highlighting the need for rapid, sensitive, and easy-to-use diagnostics. Here, we develop a single-step CRISPR-based diagnostic platform, termed SCOPE (Streamlined CRISPR On Pod Evaluation platform), for field-deployable ultrasensitive detection of MPXV in resource-limited settings. The viral nucleic acids are rapidly released from the rash fluid swab, oral swab, saliva, and urine samples in 2 min via a streamlined viral lysis protocol, followed by a 10-min single-step recombinase polymerase amplification (RPA)-CRISPR/Cas13a reaction. A pod-shaped vest-pocket analysis device achieves the whole process for reaction execution, signal acquisition, and result interpretation. SCOPE can detect as low as 0.5 copies/µL (2.5 copies/reaction) of MPXV within 15 min from the sample input to the answer. We validate the developed assay on 102 clinical samples from male patients / volunteers, and the testing results are 100% concordant with the real-time PCR. SCOPE achieves a single-molecular level sensitivity in minutes with a simplified procedure performed on a miniaturized wireless device, which is expected to spur substantial progress to enable the practice application of CRISPR-based diagnostics techniques in a point-of-care setting.
Collapse
|
33
|
Sampad MJN, Saiduzzaman SM, Walker ZJ, Wells TN, Wayment JX, Ong EM, Mdaki SD, Tamhankar MA, Yuzvinsky TD, Patterson JL, Hawkins AR, Schmidt H. Label-free and amplification-free viral RNA quantification from primate biofluids using a trapping-assisted optofluidic nanopore platform. Proc Natl Acad Sci U S A 2024; 121:e2400203121. [PMID: 38598338 PMCID: PMC11032468 DOI: 10.1073/pnas.2400203121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 03/07/2024] [Indexed: 04/12/2024] Open
Abstract
Viral outbreaks can cause widespread disruption, creating the need for diagnostic tools that provide high performance and sample versatility at the point of use with moderate complexity. Current gold standards such as PCR and rapid antigen tests fall short in one or more of these aspects. Here, we report a label-free and amplification-free nanopore sensor platform that overcomes these challenges via direct detection and quantification of viral RNA in clinical samples from a variety of biological fluids. The assay uses an optofluidic chip that combines optical waveguides with a fluidic channel and integrates a solid-state nanopore for sensing of individual biomolecules upon translocation through the pore. High specificity and low limit of detection are ensured by capturing RNA targets on microbeads and collecting them by optical trapping at the nanopore location where targets are released and rapidly detected. We use this device for longitudinal studies of the viral load progression for Zika and Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) infections in marmoset and baboon animal models, respectively. The up to million-fold trapping-based target concentration enhancement enables amplification-free RNA quantification across the clinically relevant concentration range down to the assay limit of RT-qPCR as well as cases in which PCR failed. The assay operates across all relevant biofluids, including semen, urine, and whole blood for Zika and nasopharyngeal and throat swab, rectal swab, and bronchoalveolar lavage for SARS-CoV-2. The versatility, performance, simplicity, and potential for full microfluidic integration of the amplification-free nanopore assay points toward a unique approach to molecular diagnostics for nucleic acids, proteins, and other targets.
Collapse
|
34
|
Torres-Salvador F, Ojeda J, Castro C, Gerasimova Y, Chumbimuni-Torres K. A Single Electrochemical Biosensor Designed to Detect Any Virus. Anal Chem 2024; 96:5752-5756. [PMID: 38560822 DOI: 10.1021/acs.analchem.3c05962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Viruses are the primary cause of many infectious diseases in both humans and animals. Various testing methods require an amplification step of the viral RNA sample before detection, with quantitative reverse transcription polymerase chain reaction (RT-qPCR) being one of the most widely used along with lesser-known methods like Nucleic Acid Sequence-Based Amplification (NASBA). NASBA offers several advantages, such as isothermal amplification and high selectivity for specific sequences, making it an attractive option for low-income facilities. In this research, we employed a single electrochemical biosensor (E-Biosensor) designed for potentially detecting any virus by modifying the NASBA protocol. In this modified protocol, a reverse primer is designed with an additional 22-nucleotide sequence (tag region) at the 5'-end, which is added to the NASBA process. This tag region becomes part of the final amplicon generated by NASBA. It can hybridize with a single specific E-Biosensor probe set, enabling subsequent virus detection. Using this approach, we successfully detected three different viruses with a single E-Biosensor design, demonstrating the platform's potential for virus detection.
Collapse
|
35
|
Zhao L, Wang H, Chen X, Wang L, Abulaizi W, Yang Y, Li B, Wang C, Bai X. Agarose Hydrogel-Boosted One-Tube RPA-CRISPR/Cas12a Assay for Robust Point-of-Care Detection of Zoonotic Nematode Anisakis. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:8257-8268. [PMID: 38530904 DOI: 10.1021/acs.jafc.4c00204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
Rapid and accurate detection of the zoonotic nematode Anisakis is poised to control its epidemic. The clustered regularly interspaced short palindromic repeats (CRISPR)/Cas-associated assay shows great potential in the detection of pathogenic microorganisms. The one-tube method integrated the CRISPR system with the recombinase polymerase amplification (RPA) system to avoid the risk of aerosol pollution; however, it suffers from low sensitivity due to the incompatibility of the two systems and additional manual operations. Therefore, in the present study, the agarose hydrogel boosted one-tube RPA-CRISPR/Cas12a assay was constructed by adding the CRISPR system to the agarose hydrogel, which avoided the initially low amplification efficiency of RPA caused by the cleavage of Cas12a and achieved reaction continuity. The sensitivity was 10-fold higher than that of the one-tube RPA-CRISPR/Cas12a system. This method was used for Anisakis detection within 80 min from the sample to result, achieving point-of-care testing (POCT) through a smartphone and a portable device. This study provided a novel toolbox for POCT with significant application value in preventing Anisakis infection.
Collapse
|
36
|
Yang L, Chen G, Wu J, Wei W, Peng C, Ding L, Chen X, Xu X, Wang X, Xu J. A PAM-Free One-Step Asymmetric RPA and CRISPR/Cas12b Combined Assay (OAR-CRISPR) for Rapid and Ultrasensitive DNA Detection. Anal Chem 2024; 96:5471-5477. [PMID: 38551977 DOI: 10.1021/acs.analchem.3c05545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
Current research endeavors have focused on the combination of various isothermal nucleic acid amplification methods with CRISPR/Cas systems, aiming to establish a more sensitive and reliable molecular diagnostic approach. Nevertheless, most assays adopt a two-step procedure, complicating manual operations and heightening the risk of contamination. Efforts to amalgamate both assays into a single-step procedure have faced challenges due to their inherent incompatibility. Furthermore, the presence of the protospacer adjacent motif (PAM) motif (e.g., TTN or TTTN) in the target double-strand DNA (dsDNA) is an essential prerequisite for the activation of the Cas12-based method. This requirement imposes constraints on crRNA selection. To overcome such limitations, we have developed a novel PAM-free one-step asymmetric recombinase polymerase amplification (RPA) coupled with a CRISPR/Cas12b assay (OAR-CRISPR). This method innovatively merges asymmetric RPA, generating single-stranded DNA (ssDNA) amenable to CRISPR RNA binding without the limitations of the PAM site. Importantly, the single-strand cleavage by PAM-free crRNA does not interfere with the RPA amplification process, significantly reducing the overall detection times. The OAR-CRISPR assay demonstrates sensitivity comparable to that of qPCR but achieves results in a quarter of the time required by the latter method. Additionally, our OAR-CRISPR assay allows the naked-eye detection of as few as 60 copies/μL DNA within 8 min. This innovation marks the first integration of an asymmetric RPA into one-step CRISPR-based assays. These advancements not only support the progression of one-step CRISPR/Cas12-based detection but also open new avenues for the development of detection methods capable of targeting a wide range of DNA targets.
Collapse
|
37
|
Zhan Y, Mao Y, Sun P, Liu C, Gou H, Qi H, Chen G, Hu S, Tian B. Tumor-associated antigen-specific cell imaging based on upconversion luminescence and nucleic acid rolling circle amplification. Mikrochim Acta 2024; 191:248. [PMID: 38587676 DOI: 10.1007/s00604-024-06331-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 03/24/2024] [Indexed: 04/09/2024]
Abstract
Tumor-associated antigen (TAA)-based diagnosis has gained prominence for early tumor screening, treatment monitoring, prognostic assessment, and minimal residual disease detection. However, limitations such as low sensitivity and difficulty in extracting non-specific binding membrane proteins still exist in traditional detection methods. Upconversion luminescence (UCL) exhibits unique physical and chemical properties under wavelength near-infrared light excitation. Rolling circle amplification (RCA) is an efficient DNA amplification technique with amplification factors as high as 105. Therefore, the above two excellent techniques can be employed for highly accurate imaging analysis of tumor cells. Herein, we developed a novel nanoplatform for TAA-specific cell imaging based on UCL and RCA technology. An aptamer-primer complex selectively binds to Mucin 1 (MUC1), one of TAA on cell surface, to trigger RCA reaction, generating a large number of repetitive sequences. These sequences provide lots of binding sites for complementary signal probes, producing UCL from lanthanide-doped upconversion nanoparticles (UCNPs) after releasing quencher group. The experimental results demonstrate the specific attachment of upconversion nanomaterials to cancer cells which express a high level of MUC1, indicating the potential of UCNPs and RCA in tumor imaging.
Collapse
|
38
|
Polat C, Ayhan N, Ergünay K, Charrel RN. Comprehensive evaluation of nucleic acid amplification methods widely used for generic detection of sandfly-borne phleboviruses. Microbiol Spectr 2024; 12:e0342823. [PMID: 38456695 PMCID: PMC10986501 DOI: 10.1128/spectrum.03428-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 02/13/2024] [Indexed: 03/09/2024] Open
Abstract
Sandfly-borne phleboviruses (SBPs), which cause sandfly fever, aseptic meningitis, encephalitis, and meningoencephalitis, are emerging pathogens of major public health concern. Virus nucleic acid testing is essential for SBP diagnosis, especially in the early stages of infection, and for the discovery of novel SBPs. The efficacy of utilizing generic primers that target conserved nucleotide sequences for the detection of both known and novel SBPs has not been extensively evaluated. We aimed to compare and evaluate the performance of five generic primer sets, widely used to detect S- and L-segments of arthropod-borne phleboviruses and designed as singleplex (n = 3) and nested (n = 2) formats, including both well-known and recently characterized 15 Old World virus strains. Furthermore, we performed in silico analysis to assess the detection capabilities of these generic primer sets. The initial evaluation of previously published generic primer sets for SBP detection yielded two singleplex primer sets with the potential to be adapted for use in real-time or high-throughput detection settings. Studies are ongoing to develop and further optimize a preliminary assay and test various hosts and vectors to assess their capacity to detect known and novel viruses. IMPORTANCE Virus nucleic acid testing is the primary diagnostic method, particularly in the early stages of illness. Virus-specific or syndromic tests are widely used for this purpose. The use of generic primers has had a considerable impact on the discovery, identification, and detection of Old World sandfly-borne phleboviruses (OWSBP). The study is significant because it is the first to carry out a comparative evaluation of all published OWSBP generic primer sets.
Collapse
|
39
|
Zhu D, Su T, Sun T, Qin X, Su S, Bai Y, Li F, Zhao D, Shao G, Chao J, Feng Z, Wang L. Enhancing Point-of-Care Diagnosis of African Swine Fever Virus (ASFV) DNA with the CRISPR-Cas12a-Assisted Triplex Amplified Assay. Anal Chem 2024; 96:5178-5187. [PMID: 38500378 DOI: 10.1021/acs.analchem.3c05364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Accurate, ultrasensitive, and point-of-care (POC) diagnosis of the African swine fever virus (ASFV) remains imperative to prevent its spread and limit the losses incurred. Herein, we propose a CRISPR-Cas12a-assisted triplex amplified colorimetric assay for ASFV DNA detection with ultrahigh sensitivity and specificity. The specific recognition of recombinase aided amplification (RAA)-amplified ASFV DNA could activate the Cas12a/crRNA/ASFV DNA complex, leading to the digestion of the linker DNA (bio-L1) on magnetic beads (MBs), thereby preventing its binding of gold nanoparticles (AuNPs) network. After magnetic separation, the release of AuNPs network comprising a substantial quantity of AuNPs could lead to a discernible alteration in color and significantly amplify the plasmonic signal, which could be read by spectrophotometers or smartphones. By combining the RAA, CRISPR/Cas12a-assisted cleavage, and AuNPs network-mediated colorimetric amplification together, the assay could detect as low as 0.1 copies/μL ASFV DNA within 1 h. The assay showed an accuracy of 100% for the detection of ASFV DNA in 16 swine tissue fluid samples, demonstrating its potential for on-site diagnosis of ASFV.
Collapse
|
40
|
Zhao X, Zeng Y, Yan B, Liu Y, Qian Y, Zhu A, Zhao Y, Zhang X, Zhang C, Wan Z. A novel extraction-free dual HiFi-LAMP assay for detection of methicillin-sensitive and methicillin-resistant Staphylococcus aureus. Microbiol Spectr 2024; 12:e0413323. [PMID: 38376361 PMCID: PMC10986577 DOI: 10.1128/spectrum.04133-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 01/26/2024] [Indexed: 02/21/2024] Open
Abstract
Staphylococcus aureus (S. aureus) is a leading cause of bacteremia and blood stream infections. Methicillin-resistant S. aureus (MRSA) that first appeared in 1961 often caused hospital-acquired infections (HAIs) and community-acquired infections (CAIs) and was associated with high mortality rate. Accurate and rapid point-of-care testing (POCT) of MRSA is crucial for clinical management and treatment of MRSA infections, as well as the prevention and control of HAIs and CAIs. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of methicillin-susceptible S. aureus and MRSA. The dual HiFi-LAMP assay can detect 30 copies/reaction of nuc and mecA genes with detection limits of 147 and 158 copies per 25 µL reaction, respectively. A retrospective clinical evaluation with 107 clinical S. aureus isolates showed both sensitivity and specificity of 100%. A prospective clinical evaluation with 35 clinical samples revealed a specificity of 100% and a sensitivity of 92.3%. The dual HiFi-LAMP assay can detect almost all S. aureus samples (141/142; 99.3%) within 20 min, implying that the entire HiFi-LAMP assay (including sample process) can be completed within 40 min, extremely significantly shorter than 3-5 days by the traditional clinical microbial culture and antibiotic susceptibility testing. The novel extraction-free dual HiFi-LAMP assay can be used as a robust POCT tool to promote precise diagnosis and treatment of MRSA infections in hospitals and to facilitate surveillance of MRSA at hospital and community settings.IMPORTANCEMethicillin-resistant Staphylococcus aureus (MRSA) was associated with high mortality rate and listed as a "priority pathogen" by the World Health Organization. Accurate and rapid point-of-care testing (POCT) of MRSA is critically required for clinical management and treatment of MRSA infections. Some previous LAMP-based POCT assays for MRSA might be questionable due to their low specificity and the lack of appropriate evaluation directly using clinical samples. Furthermore, they are relatively tedious and time-consuming because they require DNA extraction and lack multiplex detection capacity. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of MRSA and methicillin-susceptible S. aureus. The assay has high specificity and sensitivity and can be completed within 40 min. Clinical evaluation with real clinical samples and clinical isolates showed excellent performance with 100% specificity and 92.3%-100% sensitivity. The novel extraction-free assay may be a robust POCT tool to promote precise diagnosis of MRSA infections and facilitate surveillance of MRSA at hospital and community settings.
Collapse
|
41
|
Inagaki T, Asahi S, Ogawa K, Nakagawa T, Ohkura T, Osada Y, Nikai T, Yamada K, Yagi T, Uchiya KI. Development of a rapid detection method for the macrolide resistance gene in Mycobacterium avium using the amplification refractory mutation system-loop-mediated isothermal amplification method. Microbiol Spectr 2024; 12:e0233923. [PMID: 38363108 PMCID: PMC10986505 DOI: 10.1128/spectrum.02339-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 01/22/2024] [Indexed: 02/17/2024] Open
Abstract
Macrolide antibiotics such as clarithromycin (CLR) and azithromycin are the key drugs used in multidrug therapy for Mycobacterium avium complex (MAC) diseases. For these antibacterial drugs, drug susceptibility has been correlated with clinical response in MAC diseases. We have previously demonstrated the correlation between drug susceptibility and mutations in the 23S rRNA gene, which confers resistance to macrolides. Herein, we developed a rapid detection method using the amplification refractory mutation system (ARMS)-loop-mediated isothermal amplification (LAMP) technique to identify mutations in the 23S rRNA gene of M. avium. We examined the applicability of the ARMS-LAMP method to genomic DNA extracted from six genotypes of M. avium clinical isolates. The M. avium isolates were classified into 21 CLR-resistant and 9 CLR-susceptible strains based on the results of drug susceptibility tests; the 23S rRNA genes of these strains were sequenced and analyzed using the ARMS-LAMP method. Sequence analysis revealed that the 9 CLR-sensitive strains were wild-type strains, whereas the 21 CLR-resistant strains comprised 20 mutant-type strains and one wild-type strain. Using ARMS-LAMP, no amplification from genomic DNAs of the 10 wild-type strains was observed using the mutant-type mismatch primer sets (MTPSs); however, amplification from the 20 mutant-type strain DNAs was observed using the MTPSs. The rapid detection method developed by us integrates ARMS-LAMP with a real-time turbidimeter, which can help determine drug resistance in a few hours. In conclusion, ARMS-LAMP might be a new clinically beneficial technology for rapid detection of mutations.IMPORTANCEMultidrug therapy for pulmonary Mycobacterium avium complex disease is centered on the macrolide antibiotics clarithromycin and azithromycin, and resistance to macrolides is an important prognosticator for clinical aggravation. Therefore, it is important to develop a quick and easy method for detecting resistance to macrolides. Drug resistance is known to be correlated with mutations in macrolide resistance genes. We developed a rapid detection method using amplification refractory mutation system (ARMS)-loop-mediated isothermal amplification (LAMP) to identify a mutation in the 23S rRNA gene, which is a macrolide resistance gene. Furthermore, we examined the applicability of this method using M. avium clinical isolates. The rapid method developed by us for detection of the macrolide resistance gene by integrating ARMS-LAMP and a real-time turbidimeter can help in detection of drug resistance within a few hours. Since this method does not require expensive equipment or special techniques and shows high analytical speed, it would be very useful in clinical practice.
Collapse
|
42
|
Faddy HM, Osiowy C, Custer B, Busch M, Stramer SL, Adesina O, van de Laar T, Tsoi WC, Styles C, Kiely P, Margaritis A, Kwon SY, Qiu Y, Deng X, Lewin A, Jørgensen SW, Erikstrup C, Juhl D, Sauleda S, Camacho Rodriguez BA, Coral LJCS, Gaviria García PA, Oota S, O'Brien SF, Wendel S, Castro E, Navarro Pérez L, Harvala H, Davison K, Reynolds C, Jarvis L, Grabarczyk P, Kopacz A, Łętowska M, O'Flaherty N, Young F, Williams P, Burke L, Chua SS, Muylaert A, Page I, Jones A, Niederhauser C, Vermeulen M, Laperche S, Gallian P, Sawadogo S, Satake M, Gharehbaghian A, Addas-Carvalho M, Blanco S, Gallego SV, Seltsam A, Weber-Schehl M, Al-Riyami AZ, Al Maamari K, Alawi FB, Pandey HC, Mbanya D, França RA, Charlewood R. International review of blood donation nucleic acid amplification testing. Vox Sang 2024; 119:315-325. [PMID: 38390819 DOI: 10.1111/vox.13592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 01/01/2024] [Accepted: 01/02/2024] [Indexed: 02/24/2024]
Abstract
BACKGROUND AND OBJECTIVES Nucleic acid amplification testing (NAT), in blood services context, is used for the detection of viral and parasite nucleic acids to reduce transfusion-transmitted infections. This project reviewed NAT for screening blood donations globally. MATERIALS AND METHODS A survey on NAT usage, developed by the International Society of Blood Transfusion Working Party on Transfusion-transmitted Infectious Diseases (ISBT WP-TTID), was distributed through ISBT WP-TTID members. Data were analysed using descriptive statistics. RESULTS Forty-three responses were received from 32 countries. Increased adoption of blood donation viral screening by NAT was observed over the past decade. NAT-positive donations were detected for all viruses tested in 2019 (proportion of donations positive by NAT were 0.0099% for human immunodeficiency virus [HIV], 0.0063% for hepatitis C virus [HCV], 0.0247% for hepatitis B virus [HBV], 0.0323% for hepatitis E virus [HEV], 0.0014% for West Nile virus [WNV] and 0.00005% for Zika virus [ZIKV]). Globally, over 3100 NAT-positive donations were identified as NAT yield or solely by NAT in 2019 and over 22,000 since the introduction of NAT, with HBV accounting for over half. NAT-positivity rate was higher in first-time donors for all viruses tested except WNV. During 2019, a small number of participants performed NAT for parasites (Trypanosoma cruzi, Babesia spp., Plasmodium spp.). CONCLUSION This survey captures current use of blood donation NAT globally. There has been increased NAT usage over the last decade. It is clear that NAT contributes to improving blood transfusion safety globally; however, there is a need to overcome economic barriers for regions/countries not performing NAT.
Collapse
|
43
|
Kumar S, Raman S, Sesham K, Gupta A, Yadav RK, Mridha AR, Yadav SC. Visual, rapid, and cost-effective BK virus detection system for renal transplanted patients using gold nanoparticle coupled loop-mediated isothermal amplification (nanoLAMP). J Virol Methods 2024; 325:114889. [PMID: 38290650 DOI: 10.1016/j.jviromet.2024.114889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 01/13/2024] [Accepted: 01/17/2024] [Indexed: 02/01/2024]
Abstract
A substantial percentage of kidney transplant recipients show transplant failure due to BK virus-induced nephropathy. This can be clinically controlled by the rapid and timely detection of BK virus infection in immune-compromised patients. We report a rapid (two hours from sample collection, processing, and detection), cost-effective (< 2$), highly sensitive and BKV-specific nanoLAMP (loop-mediated isothermal amplification) diagnostic methodology using novel primers and gold nanoparticles complex-based visual detection. The standardized nanoLAMP showed an analytical sensitivity of 25 copies/µl and did not cross-react with closely related JC and SV40 viruses. This nanoLAMP showed diagnostic sensitivity and specificity as 91% and 96%, respectively, taking 50 BK virus-negative (confirmed by qPCR from the plasma of healthy donors) and 57 positive BKV patient samples (confirmed by clinical parameters and qPCR assay). This simple two-step, low-cost, and quick (1-2 h/test) detection would be advantageous over the currently used diagnostic methodology. It may change the paradigm for polyomavirus infection-based failure of renal transplant.
Collapse
|
44
|
Filaire F, Sécula A, Lebre L, Croville G, Guerin JL. A real-time colourimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of highly pathogenic H5 clade 2.3.4.4b avian influenza viruses. Avian Pathol 2024; 53:93-100. [PMID: 37885409 DOI: 10.1080/03079457.2023.2276849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 10/24/2023] [Indexed: 10/28/2023]
Abstract
Highly pathogenic avian influenza viruses (HPAIV) are a major threat to the global poultry industry and public health due to their zoonotic potential. Since 2016, Europe and France have faced major epizootics caused by clade 2.3.4.4b H5 HPAIV. To reduce sample-to-result times, point-of-care testing is urgently needed to help prevent further outbreaks and the propagation of the virus. This study presents the design of a novel real-time colourimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the detection of clade 2.3.4.4b H5 HPAIV. A clinical validation of this RT-LAMP assay was performed on 198 pools of clinical swabs sampled in 52 poultry flocks during the H5 HPAI 2020-2022 epizootics in France. This RT-LAMP assay allowed the specific detection of HPAIV H5Nx clade 2.3.4.4b within 30 min with a sensitivity of 86.11%. This rapid, easy-to-perform, inexpensive, molecular detection assay could be included in the HPAIV surveillance toolbox.
Collapse
|
45
|
Mittal V, Kumar M, Singh AK. TB LAMP assay, a beneficial tool for the diagnosis of Tubercular meningitis in resource-limited settings. J Infect Dev Ctries 2024; 18:435-440. [PMID: 38635619 DOI: 10.3855/jidc.18115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 07/03/2023] [Indexed: 04/20/2024] Open
Abstract
INTRODUCTION Tubercular meningitis (TBM) is a serious public health problem in developing countries as it leads to significant mortality and residual neurological sequelae. The estimated mortality due to TBM in India is 1.5 per 100,000 population. In resource-limited settings, only the Ziehl-Neelsen (ZN) stain, which has very little sensitivity, is available. The World Health Organization recommended the Loop Mediated Isothermal Amplification (TB LAMP) assay for pulmonary tuberculosis only. We evaluated this test for tubercular meningitis as well. METHODOLOGY In a cross-sectional study of 2-year duration, we have taken 239 cerebrospinal fluid samples from suspected cases of tubercular meningitis patients. ZN staining along with Mycobacteria Growth Indicator Tube (MGIT) TB culture, Xpert MTB/RIF Ultra assay, and commercial TB LAMP assay were performed for each sample. RESULTS Out of 239 samples, 40 samples (16.73%) were found TB LAMP assay positive, 48 samples (20.08%) were found Xpert ultra-assay positive, 12 samples (5.02%) were MGIT TB culture positive and acid-fast bacillus smear positive in ten samples (4.18 %). Out of 12 MGIT-positive samples, all samples (100%) were TB LAMP and Xpert ultra positive and one sample (8.33%) was ZN smear positive. In 199 negative samples from the TB LAMP assay, eight samples were positive by Xpert, none by MGIT TB culture and AFB smear. Sensitivity and specificity were found as 100% and 87.66%, respectively, for the TB LAMP assay. CONCLUSION TB LAMP assay is a rapid, cost-effective, sensitive, and specific test for tubercular meningitis infection in resource-limited settings.
Collapse
|
46
|
Lai JX, Qin YR, Liao YW, Si YT, Yuan Q, Huang SM, Tang YR, Wang JL, Wang L. Rapid Detection of Bacterial Pathogens Causing Lower Respiratory Tract Infections via Microfluidic-Chip-Based Loop-Mediated Isothermal Amplification. J Vis Exp 2024. [PMID: 38619279 DOI: 10.3791/66677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2024] Open
Abstract
Respiratory tract infections (RTIs) are among the most common problems in clinical settings. Rapid and accurate identification of bacterial pathogens will provide practical guidelines for managing and treating RTIs. This study describes a method for rapidly detecting bacterial pathogens that cause respiratory tract infections via multi-channel loop-mediated isothermal amplification (LAMP). LAMP is a sensitive and specific diagnostic tool that rapidly detects bacterial nucleic acids with high accuracy and reliability. The proposed method offers a significant advantage over traditional bacterial culturing methods, which are time-consuming and often require greater sensitivity for detecting low levels of bacterial nucleic acids. This article presents representative results of K. pneumoniae infection and its multiple co-infections using LAMP to detect samples (sputum, bronchial lavage fluid, and alveolar lavage fluid) from the lower respiratory tract. In summary, the multi-channel LAMP method provides a rapid and efficient means of identifying single and multiple bacterial pathogens in clinical samples, which can help prevent the spread of bacterial pathogens and aid in the appropriate treatment of RTIs.
Collapse
|
47
|
Mellikeche W, Ricelli A, Casini G, Gallo M, Baser N, Colelli G, D’Onghia AM. Development of Loop-Mediated Isothermal Amplification (LAMP) Assays for the Rapid Detection of Toxigenic Aspergillus flavus and A. carbonarius in Nuts. Int J Mol Sci 2024; 25:3809. [PMID: 38612622 PMCID: PMC11011790 DOI: 10.3390/ijms25073809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/21/2024] [Accepted: 03/22/2024] [Indexed: 04/14/2024] Open
Abstract
Aspergillus species create major postharvest problems due to the food losses caused by their mere presence and the hazardous mycotoxins they produce, such as aflatoxin B1 (AFB1) and ochratoxin A (OTA). These mycotoxins are mainly produced by A. flavus and A. carbonarius, respectively. In this study, we developed a rapid detection method for the two aforementioned species based on loop-mediated isothermal amplification (LAMP). The primers were designed to target genes belonging to the mycotoxin clusters pks and aflT for A. carbonarius and A. flavus, respectively. Result visualization was carried out in real time via the detection of fluorescent signals. The method developed showed high sensitivity and specificity, with detection limits of 0.3 and 0.03 pg/reaction of purified DNA of A. carbonarius and A. flavus, respectively. The assays were further implemented on inoculated nuts, including pistachios and almonds, after one-step crude DNA extraction. These tests revealed a detection level of 0.5 spore/g that shows the effectiveness of LAMP as a rapid method for detecting potentially toxigenic Aspergillus spp. directly in food. The validation of the assays included tests on a larger scale that further confirmed their sensitivity and specificity, as well as enabling the production of ready-to-use LAMP prototype kits. These kits are easy to use and aim to simplify the screening of food samples in order to monitor the presence of specific Aspergillus contaminations.
Collapse
|
48
|
Kumagai H, Furusawa H. Real-Time Monitoring of a Nucleic Acid Amplification Reaction Using a Mass Sensor Based on a Quartz-Crystal Microbalance. BIOSENSORS 2024; 14:155. [PMID: 38667148 PMCID: PMC11048521 DOI: 10.3390/bios14040155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/21/2024] [Accepted: 03/23/2024] [Indexed: 04/28/2024]
Abstract
Nucleic acid amplification reactions such as polymerase chain reaction (PCR), which uses a DNA polymerase to amplify individual double-stranded DNA fragments, are a useful technique for visualizing the presence of specific genomes. Although the fluorescent labeling method is mainly used with DNA amplification, other detection methods should be considered for further improvements, such as miniaturization and cost reduction, of reaction-monitoring devices. In this study, the quartz-crystal microbalance (QCM) method, which can measure nanogram-order masses, was applied for the real-time detection of DNA fragments in a solution with nucleic acids. This was combined with an isothermal nucleic acid amplification reaction based on the recombinase polymerase amplification (RPA) method, which allowed DNA amplification at a constant temperature. When the DNA amplification reaction was initiated on a QCM sensor plate with an immobilized primer DNA strand, a significant increase in mass was observed compared to when the primer DNA was not immobilized. QCM was shown to be sufficiently sensitive for the in situ detection of amplified DNA fragments. Combining a portable QCM device and RPA offers a sensitive point-of-care method for detecting nucleic acids.
Collapse
|
49
|
Shi C, Yang D, Ma X, Pan L, Shao Y, Arya G, Ke Y, Zhang C, Wang F, Zuo X, Li M, Wang P. A Programmable DNAzyme for the Sensitive Detection of Nucleic Acids. Angew Chem Int Ed Engl 2024; 63:e202320179. [PMID: 38288561 DOI: 10.1002/anie.202320179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Indexed: 02/17/2024]
Abstract
Nucleic acids in biofluids are emerging biomarkers for the molecular diagnostics of diseases, but their clinical use has been hindered by the lack of sensitive detection assays. Herein, we report the development of a sensitive nucleic acid detection assay named SPOT (sensitive loop-initiated DNAzyme biosensor for nucleic acid detection) by rationally designing a catalytic DNAzyme of endonuclease capability into a unified one-stranded allosteric biosensor. SPOT is activated once a nucleic acid target of a specific sequence binds to its allosteric module to enable continuous cleavage of molecular reporters. SPOT provides a highly robust platform for sensitive, convenient and cost-effective detection of low-abundance nucleic acids. For clinical validation, we demonstrated that SPOT could detect serum miRNAs for the diagnostics of breast cancer, gastric cancer and prostate cancer. Furthermore, SPOT exhibits potent detection performance over SARS-CoV-2 RNA from clinical swabs with high sensitivity and specificity. Finally, SPOT is compatible with point-of-care testing modalities such as lateral flow assays. Hence, we envision that SPOT may serve as a robust assay for the sensitive detection of a variety of nucleic acid targets enabling molecular diagnostics in clinics.
Collapse
|
50
|
Peirano G, Castellanos LR, Matsumura Y, Chaffee R, Castañeda-Mogollón D, Pillai DR, Pitout JDD. Clinical validation of loop-mediated isothermal amplification for the detection of Escherichia coli sequence type complex 131. J Clin Microbiol 2024; 62:e0168723. [PMID: 38385692 PMCID: PMC10935629 DOI: 10.1128/jcm.01687-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 02/02/2024] [Indexed: 02/23/2024] Open
Abstract
The dissemination of Escherichia coli multidrug-resistant (MDR) STc131 is related to its persistence in the human gastrointestinal tract as efficient gut colonizers. Infection and prevention measures are the cornerstones for preventing STc131 spread. Oral decolonization therapies that target ST131 are being developed. There are no rapid methods available to identify STc131 in human specimens. A loop-mediated isothermal amplification (LAMP) assay (named LAMP-ST131) was developed for the detection of STc131 on well-characterized E. coli isolates and then compared to culture and PCR for urines and stool swabs. With E. coli isolates (n = 720), LAMP-ST131 had a sensitivity (sens) of 100% [95% confidence interval (C.I.) = 98.1-100%)] and a specificity (spec) of 98.9% (95% C.I. = 97.5-99.5%). On urines (n = 550), LAMP-ST131 had a sens of 97.6% (95% C.I. = 89.68-94.33%) and a spec of 92.3% (95% C.I. = 87.68-99.88%), while on stool swabs (n = 278), LAMP-ST131 had a sens of 100% (95% C.I. = 88.7-100%) and a spec of 83.9% (95% C.I. = 78.8-87.9%). LAMP-ST131 detected 10 (urines) and 100 (stool swabs) gene copies/μL. LAMP-ST131 accurately identified STc131 within E. coli isolates and human specimens. The implementation of LAMP-ST131 will aid genomic surveys, enable the rapid implementation of effective infection prevention measures, and identify patients suitable for ST131 decolonization therapies. Such approaches will curb the spread of STc131 and decrease incidence rates of global MDR E. coli infections. IMPORTANCE We developed an accurate non-culture-based loop-mediated isothermal amplification (LAMP) methodology for the detection of (sequence type) STc131 among Escherichia coli isolates and human specimens. The use of LAMP-ST131 for global genomic surveillance studies and to identify patients that are suitable for ST131 decolonization therapies will be important for decreasing multidrug-resistant E. coli infections across the globe.
Collapse
|