26
|
Lampl Y, Lorberboym M, Blankenberg FG, Sadeh M, Gilad R. Annexin V SPECT imaging of phosphatidylserine expression in patients with dementia. Neurology 2006; 66:1253-4. [PMID: 16636246 DOI: 10.1212/01.wnl.0000208436.75615.8c] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The authors sought to use radiolabeled annexin V, a marker of phosphatidylserine expression, to image Alzheimer dementia (AD). Four of five patients with AD had multifocal cortical annexin V uptake, whereas all seven non-AD and six control patients had normal SPECT. The mean cortex/cerebellar activity in patients with AD (1.4 +/- 0.6) was higher than that of non-AD dementia patients (0.7 +/- 0.2; p = 0.02). Radiolabeled annexin V may be useful for imaging AD.
Collapse
|
27
|
Paiva GR, Filho RSO, Ferreira LM, Wagner J, Nogueira SA, Novo NF, Juliano Y, Rocha JLBS. Phytate technetium-99m versus dextran 500 technetium-99m in the sentinel lymph node biopsy. Acta Radiol 2006; 47:65-70. [PMID: 16498935 DOI: 10.1080/02841850500406803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To study which of the two most used radiopharmaceutical drugs for the sentinel lymph node (SLN) biopsy procedure (dextran 500 99mTc and phytate 99mTc) best defines the SLN and migrates less to other lymph nodes. MATERIAL AND METHODS Thirty-two rats, separated into two groups, underwent lymphoscintigraphy examination with either dextran or phytate followed by sentinel (popliteal), lumbar, and inguinal lymph node biopsy. Radiation was detected with a gamma probe. RESULTS The statistical study indicated count rates significantly higher in the SLN than in the other basins for both the dextran (P<0.01) and phytate groups (P<0.001). There was no statistically significant difference concerning SLN absorption in either group (P=0.2981). In the dextran group, migration occurred to 1.5 lymphatic basins with counting higher than 10% of that found in the SLN versus 0.8 in the phytate group (P=0.0023). Migration was thus higher in the dextran group (P=0.0207). CONCLUSION There was no statistically significant difference between dextran and phytate in the SLN identification, but the phytate migrated to fewer lymphatic basins beyond the SLN and with less intensity.
Collapse
|
28
|
Oliva JP, Valdés Z, Casacó A, Pimentel G, González J, Alvarez I, Osorio M, Velazco M, Figueroa M, Ortiz R, Escobar X, Orozco M, Cruz J, Franco S, Díaz M, Roque L, Carr A, Vázquez AM, Mateos C, Rubio MC, Pérez R, Fernández LE. Clinical evidences of GM3 (NeuGc) ganglioside expression in human breast cancer using the 14F7 monoclonal antibody labelled with (99m)Tc. Breast Cancer Res Treat 2005; 96:115-21. [PMID: 16322892 DOI: 10.1007/s10549-005-9064-0] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2005] [Accepted: 08/23/2005] [Indexed: 11/24/2022]
Abstract
The relevance of certain gangliosides in tumour growth and metastatic dissemination has been well documented, reasons for considering these molecules as potential targets for cancer immunotherapy and diagnosis. GM3(NeuGc) ganglioside is particularly interesting due to its restrictive expression in normal human tissues according to immunohistochemical studies, using either polyclonal or monoclonal antibodies. But both immunohistochemical and biochemical methods have strongly suggested its over-expression in human breast tumours. Nevertheless, the lack of a direct evidence of this antigenic display in human breast cancer has kept the subject controversial. For the first time, we described herein the "in vivo" detection of GM3(NeuGc) ganglioside in human breast primary tumours using a radioimmunoscintigraphic technique with 14F7, a highly specific anti-GM3(NeuGc) ganglioside monoclonal antibody, labelled with (99m)Tc. In an open, prospective Phase I/II clinical trial, including women diagnosed in stage II breast cancer, the 14F7 monoclonal antibody accumulation in tumours at doses of 0.3 (n=5), 1 (n=5) and 3 mg (n=4) was evaluated. Noteworthy, the immunoscintigraphic study showed antibody accumulation in 100% of patients' tumours for the 1 mg dose group. In turn, the radioimmunoconjugate injected at doses of 0.3 mg or 3 mg of the antibody, was uptaken by 60 and 33.3% of breast tumours, respectively. "In vivo" immune recognition of GM3(NeuGc) in breast tumours reinforces the value of this peculiar target for cancer immunotherapy.
Collapse
MESH Headings
- Adolescent
- Adult
- Aged
- Aged, 80 and over
- Antibodies, Monoclonal/administration & dosage
- Breast Neoplasms/diagnostic imaging
- Breast Neoplasms/metabolism
- Breast Neoplasms/pathology
- Carcinoma, Ductal, Breast/diagnostic imaging
- Carcinoma, Ductal, Breast/metabolism
- Carcinoma, Ductal, Breast/pathology
- Dose-Response Relationship, Drug
- Female
- G(M3) Ganglioside/metabolism
- Humans
- Infusions, Intravenous
- Middle Aged
- Neoplasm Staging
- Prospective Studies
- Radioimmunodetection
- Technetium/administration & dosage
Collapse
|
29
|
Newman S, Salmon A, Nave R, Drollmann A. High lung deposition of 99mTc-labeled ciclesonide administered via HFA-MDI to patients with asthma. Respir Med 2005; 100:375-84. [PMID: 16275052 DOI: 10.1016/j.rmed.2005.09.027] [Citation(s) in RCA: 94] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2005] [Revised: 09/16/2005] [Accepted: 09/21/2005] [Indexed: 10/25/2022]
Abstract
OBJECTIVE To examine the deposition and pharmacokinetics of ciclesonide administered via hydrofluoroalkane-metered dose inhaler (HFA-MDI) in patients with asthma. METHODS Twelve patients with mild asthma (FEV1, 95% predicted) inhaled a single dose of 99mtechnetium (Tc)-ciclesonide 320 microg ex-actuator (400 microg ex-valve). Deposition of ciclesonide in the lung and oropharynx was quantified using two-dimensional (2D)-gamma scintigraphy. Three-dimensional single photon emission computed tomography (3D SPECT) was used to assess the regional distribution of ciclesonide in the lung. The pharmacokinetics of ciclesonide and its active metabolite, desisobutyryl-ciclesonide (des-CIC), were determined by liquid chromatography-tandem mass spectrometry. Ciclesonide and des-CIC concentrations were determined in mouth-rinsing solutions. RESULTS 2D-gamma scintigraphy indicated that ciclesonide deposition was higher in the whole lung (52%) than in the oropharynx (32.9%). Furthermore, 3D SPECT revealed that ciclesonide deposition within the lungs was highest in the peripheral regions that contain the small airways and alveoli. The pharmacokinetic profile of Tc-labeled ciclesonide and des-CIC was similar to that obtained after inhalation of non-labeled formulations in previous studies. Des-CIC accounted for 14.9% of the total molar concentration of ciclesonide/des-CIC in mouth-rinsing solutions obtained between 7 and 12min after inhalation. CONCLUSION Inhalation of ciclesonide via HFA-MDI results in high pulmonary deposition, especially in the peripheral regions of the lung. High pulmonary deposition contributes to ciclesonide's ability to maintain lung function and control symptoms in patients with asthma. Deposition and activation of ciclesonide in the oropharynx is low, consistent with previous reports of low oropharyngeal deposition and a reduced incidence of local side effects in patients receiving ciclesonide therapy.
Collapse
|
30
|
Bury B. Use of 99mTc labelled human immunoglobulin G for sentinel node imaging. Nucl Med Commun 2005; 26:1163; author reply 1163-4. [PMID: 16264367 DOI: 10.1097/00006231-200512000-00018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
31
|
Iznaga-Escobar N, Ramos-Suzarte M, Morales-Morales A, Torres-Arocha L, Rodríguez-Mesa N, Pérez-Rodriguez R. (99m)Tc-labeled murine ior C5 monoclonal antibody in colorectal carcinoma patients: pharmacokinetics, biodistribution, absorbed radiation doses to normal organs and tissues and tumor localization. ACTA ACUST UNITED AC 2005; 26:687-96. [PMID: 15632954 DOI: 10.1358/mf.2004.26.9.872566] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Monoclonal Antibody (mAb) ior C5 is a murine IgG(1) that recognizes the tumor associated antigen (TAA) ior C2, a cell surface O-linked glycoprotein carbohydrate chain not present in most normal tissues and homogeneously expressed in the cytoplasm of normal colon epithelium and heterogeneously expressed in more than 83% of primary colorectal carcinomas. This study was designed to investigate the pharmacokinetics, biodistribution and the absorbed radiation doses of (99m)Tc-labeled mAb ior C5 antibody in colorectal tumor patients. Ten patients were administered 3 mg of anti-O-linked glycoprotein carbohydrate chain TAA ior C2 murine monoclonal antibody ior C5 radiolabeled with (99m)Tc activity of 1435.0 +/- 123 MBq by intravenous (i.v.) bolus infusion. Blood and urine samples were collected from 4 out of 10 patients at timed intervals from 10 min and up to 24 h after injection of the (99m)Tc-labeled mAb ior C5 for pharmacokinetic studies. Whole body images were taken in 5 out of 10 patients for quantitative normal organ biodistribution and dosimetry studies and planar anterior and posterior and SPECT images were taken in 5 out of 10 patients for tumor localization. Mean absorbed doses were estimated using the methods developed by the Medical Internal Radiation Dose (MIRD) committee. The effective dose equivalent (EDE) and effective dose (ED) were calculated as prescribed in International Commission on Radiological Protection (ICRP) publications 30 and 60. Plasma disappearance curves of (99m)Tc-labeled murine antibody ior C5 were best fit by a two-compartment model in all patients with (t(1/2alpha)) of 4.32 +/- 2.18 h and (t(1/2beta) of 32.6 +/- 3.82 h. Among the main target organs, accumulation of the radiolabeled antibody was found in liver (9.38 +/- 0.80%), heart (8.92 +/- 0.94%) and spleen (1.37 +/- 0.30%) at 5 min post-administration. These values were reduced at 24 h to (5.91 +/- 0.73%) and (0.62 +/- 0.22%), respectively, for the heart and spleen and increased to (9.78 +/- 1.99%) for liver. Estimates of radiation absorbed dose to normal organs in rad/mCi administered were: whole body, 0.0181 +/- 0.0017; heart wall, 0.0768 +/- 0.0090; kidneys, 0.0530 +/- 0.0260; liver, 0.0565 +/- 0.0109 and spleen, 0.0540 +/- 0.0128. The effective dose equivalent and effective dose estimates for adults were 0.0314 +/- 0.0031 and 0.0249 +/- 0.0027 rem/mCi administered. This feasibility study indicates that the O-linked glycoprotein carbohydrate chain TAA ior C2 is expressed in primary and metastatic colorectal carcinomas and shows very limited expression in normal adult tissues. The very good pattern of biodistribution of (99m)Tc-labeled mAb ior C5 in patients will allow imaging of colorectal carcinoma lesions.
Collapse
|
32
|
Houseworth JL, Parks JA, Miguel EA, McCarthy LJ, Danielson CFM. Transfusion medicine illustrated. Iatrogenic green plasma. Transfusion 2005; 45:1047. [PMID: 15987344 DOI: 10.1111/j.1537-2995.2005.00189.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
33
|
Riksen NP, Oyen WJG, Ramakers BP, Van den Broek PHH, Engbersen R, Boerman OC, Smits P, Rongen GA. Oral therapy with dipyridamole limits ischemia-reperfusion injury in humans. Clin Pharmacol Ther 2005; 78:52-9. [PMID: 16003293 DOI: 10.1016/j.clpt.2005.03.003] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND Adenosine receptor stimulation induces several effects that could limit ischemia-reperfusion injury. We hypothesize that treatment with the nucleoside uptake inhibitor dipyridamole increases endogenous adenosine and limits ischemia-reperfusion injury in humans. METHODS Ischemia-reperfusion injury was studied in forearm skeletal muscle by technetium Tc 99m-labeled annexin A5 scintigraphy. Ischemia-reperfusion injury was induced by unilateral forearm ischemic exercise. Immediately on reperfusion, annexin A5 labeled with technetium Tc 99m was administered intravenously, and ischemia-reperfusion injury was expressed as the percentage difference in radioactivity between the experimental arm and the control arm 1 and 4 hours after reperfusion. Targeting was quantified in the region of the thenar muscle and forearm flexor muscles. This approach was used in 9 healthy male volunteers after a 1-week treatment with dipyridamole (200 mg, slow release, twice daily) and in 23 control subjects. RESULTS Dipyridamole treatment significantly reduced annexin A5 targeting in skeletal muscle compared with the control group (thenar region, 13% +/- 7% versus 22% +/- 15% at 1 hour after reperfusion and 9% +/- 6% versus 27% +/- 13% at 4 hours for dipyridamole and control groups, respectively [P = .01]; flexor region, 4% +/- 8% versus 7% +/- 6% at 1 hour after reperfusion and 1% +/- 4% versus 10% +/- 9% at 4 hours for dipyridamole and control groups, respectively [P = .01]). CONCLUSIONS One week of oral treatment with the nucleoside uptake inhibitor dipyridamole (200 mg, slow release, twice daily) significantly limits ischemia-reperfusion injury in humans in vivo, as assessed by technetium Tc 99m-labeled annexin A5 scintigraphy of forearm skeletal muscle.
Collapse
|
34
|
Nakamura K, Fan C, Liu G, Gupta S, He J, Dou S, Kubo A, Rusckowski M, Hnatowich DJ. Evidence of antisense tumor targeting in mice. Bioconjug Chem 2005; 15:1475-80. [PMID: 15546217 DOI: 10.1021/bc0499073] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Even though increased accumulations of radiolabeled antisense DNAs compared to control DNAs are becoming a routine observation in cultured tumor cells, trustworthy evidence of tumor targeting in vivo by an antisense mechanism remains elusive. The goal of this study was to obtain convincing evidence of antisense tumor targeting in nude mice by using two different tumors and both intratumoral (i.t.) and intravenous (i.v.) administration of radiolabeled antisense and control sense DNAs. Both the MDR++ cell line KB-G2 and its parent MDR+ cell line KB-31 were used in this study. The antisense (AS) DNA was directed against the AUG start codon of the MDR1 mRNA and, along with the sense (S) control DNA, was a uniform phosphorothioate administered naked. In previous cell culture studies from our laboratories, the accumulation of this AS DNA was strikingly high in KB-G2 cells and only average in KB-31 cells, a fact we attribute to the 1000-fold higher expression by RT-PCR of MDR1 mRNA in the former cell line. In this study, both DNAs were radiolabeled with (99m)Tc via MAG3 and administered i.t. or i.v. at 1 microg (100 microCi) per animal 24 h prior to sacrifice and dissection in mice bearing thigh tumors of about 1 g. Following i.t. administration, no statistically significant differences (Student's t test, p < 0.05, N = 4) between the AS and S DNA biodistributions in normal tissues were observed except in the KB-G2 mice in which muscle levels were lower for the S control. In contrast, tumor levels in the KB-G2 animals were significantly higher for the AS DNA vs S DNA (14.7 vs 8.5% ID/g) while this difference (8.6 vs 4.3% ID/g) was insignificant in the KB-31 animals. The whole body images obtained just prior to sacrifice clearly show improved targeting of AS DNA vs S DNA in the KB-G2 but not the KB-31 animals. Calculations based on these results show that about 60 000 AS DNAs accumulated specifically (i.e. AS DNA - S DNA) per KB-G2 tumor cell following i.t. administration. When administered i.v. rather than i.t., higher tumor levels in KB-G2 animals compared to KB-31 were not observed, most likely because of the lower dosage reaching the tumors. When the KB-G2 and KB-31 results are combined, no statistically significant differences between the AS and S DNA biodistributions in normal tissues were observed except in blood in which S DNA levels were higher and in spleen in which they were lower. In contrast, tumor levels were significantly higher for the AS DNA vs S DNA (0.100 vs 0.063% ID/g). Calculations based on these results show that about 400 AS DNAs accumulated specifically per tumor cell following i.v. administration. Therefore evidence for tumor targeting in vivo by an antisense mechanism has been obtained in that statistically higher tumor accumulations of the (99m)Tc-AS DNA were observed compared to the control (99m)Tc-S DNA both following i.t. and i.v. administrations. The successful localization of AS DNA in tumor demonstrates that in vivo AS targeting of tumor is feasible although improvements in tumor delivery and normal tissue clearance are needed for practical antisense imaging.
Collapse
|
35
|
Rocha Filho W, Noronha VX, Senna SN, Simal CJR, Mendonça WB. [Evaluation of the influence of patient age and spacer device volume on aerosol lung deposition]. J Pediatr (Rio J) 2004; 80:387-90. [PMID: 15505734 DOI: 10.2223/1223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
OBJECTIVE To evaluate the efficacy of three frequently used spacer devices to deliver aerosol to the lung, and to compare radioaerosol deposition with each device in different age groups. METHODS Nine healthy, non-smoking volunteers were recruited: three adults and six children, including three toddlers and three school age children. Qualitative and semi-quantitative analysis of radioaerosol deposition in the lung were carried out. Yet, two small-volume devices (Aerochamber and Inal-Air) and one large-volume device (Flumax) were compared. Each patient inhaled 99mtechnetium-phytate. The device was filled during 30 seconds with radioaerosol. Oxygen was used as the driving gas. During 10 seconds, the patients inhaled the radioaerosol. The radiation emitted at the front and back of the chest was measured. The radiation inside the device was also measured. RESULTS The quantitative evaluation of lung deposition revealed that the younger the patient, the less aerosol was deposited in the lung with the large-volume spacer device (Flumax). The difference between small-volume devices (Aerochamber and Inal-Air) was not significant. CONCLUSION Small-volume spacers are the most appropriate for children. Large-volume devices should only be used by adolescents and adults.
Collapse
|
36
|
Crawley MT, Murphy P, Jamous A, Bodley R. A low-dose radioisotope procedure for assessment of subcutaneous drug delivery systems used for slow intrathecal infusion of antispasmodic agents. Spinal Cord 2004; 42:581-4. [PMID: 15326469 DOI: 10.1038/sj.sc.3101634] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
STUDY DESIGN Retrospective single centre study. OBJECTIVES To evaluate a low-dose radioisotope imaging procedure for assessment of implanted intrathecal drug delivery and to compare the radiation dose and diagnostic value of these studies with other reported studies using higher administered radiation dose. SETTING National Spinal Injuries Centre, Stoke Mandeville Hospital, UK. METHOD A total of 11 spinally injured patients with subcutaneous drug delivery systems and uncontrolled spasm were investigated for catheter failure using a low-dose radioisotope procedure with an administered dose of radioactivity of 40 MBq Technetium-99m. RESULTS Loss of catheter patency was demonstrated in six patients, enabling identification of the site of blockage. Catheter patency and subsequent perfusion of CSF (ie normal result) was demonstrated in five patients. Radiation effective dose was estimated at 1.3 mSv per patient study, with a low associated risk of deleterious effect of one in 13,000. CONCLUSION Radioisotope investigation using a reduced administered dose of 40 MBq Technetium-99m DTPA, formulated according to a strict radiopharmaceutical protocol, provides a safe test for assessment of intrathecal drug delivery systems.
Collapse
|
37
|
van Wessem KJP, Meijer WS. Sentinel lymph node biopsy in breast cancer: results of intradermal periareolar tracer injection and follow-up of sentinel lymph node-negative patients. Breast 2004; 13:290-6. [PMID: 15325663 DOI: 10.1016/j.breast.2004.03.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2004] [Revised: 03/04/2004] [Accepted: 03/30/2004] [Indexed: 12/01/2022] Open
Abstract
Several methods are in use for identification of the sentinel lymph node (SLN) in breast cancer. We set up the hypothesis that intradermal (i.d.) infra-areolar injection of technetium-99m in combination with i.d. injection of patent blue dye lateral to the areola can identify the same lymph node as peritumoral injection, regardless of the location of the tumour. Each of 50 patients with breast cancer (group I) received an i.d. injection of technetium-99m 1cm caudal to the areola. After induction, blue dye was injected intradermally 1cm lateral to the areola. These patients underwent axillary dissection regardless of their lymph node status. The SLN was identified in 96% of these patients. One of them had axillary lymph node metastases even though the SLN was negative (6%). Further 82 patients (group II) underwent SLN identification and removal without further axillary dissection. The duration of mean follow-up for these patients was 28 months (16-39 months). One patient developed axillary recurrence (1%) 24 months after the initial operation. Intradermal periareolar tracer injection is an accurate method of locating the sentinel node. Long-term follow-up of patients who had negative sentinel nodes and did not undergo axillary dissection revealed a low axillary recurrence rate.
Collapse
|
38
|
Nieweg OE, Tanis PJ. Letter to the editor concerning ‘intradermal radioisotope injection optimises sentinel lymph node identification in breast cancer’. Eur J Surg Oncol 2004; 30:708-9. [PMID: 15256248 DOI: 10.1016/j.ejso.2004.04.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/08/2004] [Indexed: 11/17/2022] Open
|
39
|
Péley G, Sinkovics I, Tóth J, Farkas E, Keresztes S, Köves I. Subareolar injection of radioactive colloid for sentinel lymph node identification in breast cancer patients. Am Surg 2004; 70:625-9. [PMID: 15279188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
Sentinel lymph node biopsy (SLNB) is becoming the standard for staging the axilla in breast cancer patients in many institutions. The best method of injection is still questionable. The purpose of this study was to compare the results of SLNB using the peritumoral or the subareolar injection site. Between December 1997 and March 2000, we performed 100 SLNBs. Technecium-labeled colloidal human serum albumin was injected peritumorally (Group A, 31 patients; Group B, 31 patients) or subareolarly (Group C, 38 patients). Patent blue dye was given periareolarly (Group A) or peritumorally (Groups B and C). Preoperative lymphoscintigraphy was performed in all patients. SLNB was successful in 94 patients (94%). The identification rate improved from 80 per cent (first 25 patients) to 99 per cent (last 75). The subareolar injection of the colloid did not adversely influence the results of SLNB compared with the peritumoral injection (identification rate, 100% vs 97%; false negative rate, 6% vs 14%). The subareolar injection of colloid is a simple and at least as accurate technique as the peritumoral one. This technique can also improve the identification rate of SLNB for breast cancer patients.
Collapse
|
40
|
He J, Liu G, Gupta S, Zhang Y, Rusckowski M, Hnatowich DJ. Amplification targeting: a modified pretargeting approach with potential for signal amplification-proof of a concept. J Nucl Med 2004; 45:1087-95. [PMID: 15181145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/29/2023] Open
Abstract
UNLABELLED Conventional nuclear medicine imaging with large radiolabeled molecules such as antitumor antibodies suffers from slow localization and clearance. Pretargeting is under active investigation as an alternative using either (strept)avidin/biotin, bispecific antibodies, or oligomers. However, only the use of oligomers such as phosphorodiamidate morpholinos (MORFs) in pretargeting offers the potential of signal amplification at the target. Amplification targeting is a multistep procedure with the potential to greatly improve target localization of radioactivity (and eventually drugs) through the intermediate use of polymers conjugated with multiple copies of oligomers. OBJECTIVE This study was conducted to prove the concept in vivo in tumored mice of amplfication targeting. METHODS Nude mice bearing LS174T tumors received in order: the anti-CEA antibody MN14 conjugated with MORF, a polymer conjugated with multiple copies of complementary MORFs (cMORFs), and, finally, (99m)Tc-MORF. RESULTS In tumored animals, dual radiolabels ((99m)Tc and (111)In) were used to demonstrate that, after 18 h, about 25% of antibody MORFs in tumor were targeted with polymeric cMORFs and, after 3 h, about 12% of the polymeric cMORFs in tumor were targeted with (99m)Tc-MORF. Therefore, hybridization in tumor in both cases (i.e., polymeric cMORF to antibody MORF and radiolabeled MORF to polymeric cMORF) was surprisingly efficient given the barriers to targeting in vivo and the competition between targeting and clearance. Moles of radiolabeled MORF accumulating in tumor were more than tripled for study animals receiving all 3 injections compared with control animals not receiving the antibody or the polymer. Furthermore, MORF expression (on antibody) and cMORF expression (on polymer) were rapidly lost in normal organs such as liver, spleen, and kidneys but not in tumor, thus improving the target-to-nontarget ratios. CONCLUSION Although signal amplification has not yet been convincingly demonstrated and amplification targeting will require further studies for optimization, the concept has now been shown to be feasible.
Collapse
|
41
|
O'Mahony S, Rose SL, Chilvers AJ, Ballinger JR, Solanki CK, Barber RW, Mortimer PS, Purushotham AD, Peters AM. Finding an optimal method for imaging lymphatic vessels of the upper limb. Eur J Nucl Med Mol Imaging 2004; 31:555-63. [PMID: 14722673 DOI: 10.1007/s00259-003-1399-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2003] [Accepted: 10/17/2003] [Indexed: 11/26/2022]
Abstract
Lymphoscintigraphy involves interstitial injection of radiolabelled particulate materials or radioproteins. Although several variations in the technique have been described, their place in clinical practice remains controversial. Traditional diagnostic criteria are based primarily on lymph node appearances but in situations such as breast cancer, where lymph nodes may have been excised, these criteria are of limited use. In these circumstances, lymphatic vessel morphology takes on greater importance as a clinical endpoint, so a method that gives good definition of lymphatic vessels would be useful. In patients with breast cancer, for example, such a method, used before and after lymph node resection, may assist in predicting the development of breast cancer-related lymphoedema. The aim of this study was to optimise a method for the visualisation of lymphatic vessels. Subcutaneous (sc) and intradermal (id) injection sites were compared, and technetium-99m nanocolloid, a particulate material, was compared with (99m)Tc-human immunoglobulin (HIG), which is a soluble macromolecule. Twelve normal volunteers were each studied on two occasions. In three subjects, id (99m)Tc-HIG was compared with sc (99m)Tc-HIG, in three id (99m)Tc-nanocolloid was compared with sc (99m)Tc-nanocolloid, in three id (99m)Tc-HIG was compared with id (99m)Tc-nanocolloid and in three sc (99m)Tc-HIG was compared with sc (99m)Tc-nanocolloid. Endpoints were quality of lymphatic vessel definition, the time after injection at which vessels were most clearly visualised, the rate constant of depot disappearance ( k) and the systemic blood accumulation rate as measured by gamma camera imaging over the liver or cardiac blood pool. Excellent definition of lymphatic vessels was obtained following id injection of either radiopharmaceutical, an injection route that was clearly superior to sc. Differences between radiopharmaceuticals were less clear, although after id injection, (99m)Tc-HIG gave images that were marginally but significantly better than those given by (99m)Tc-nanocolloid. Image quality correlated inversely with time after injection at which the best image was obtained, consistent with the notion that good vessel definition was dependent on a "narrow" bolus width. k was approximately three times higher after id injection than after sc injection but it was not significantly different between radiopharmaceuticals for either injection route. Intradermal (99m)Tc-HIG gave a cardiac blood pool signal that, over the first 60 min, increased about five times faster than that with sc (99m)Tc-HIG, but no clear difference was observed in the rate of increase in hepatic activity between id (99m)Tc-nanocolloid and sc (99m)Tc-nanocolloid. We conclude that id injection provides rapid access of radiotracers to lymphatic vessels, which is ideal for imaging lymphatic vessel morphology. (99m)Tc-HIG is marginally superior to nanocolloid for this purpose and, in drainage basins from which lymph nodes have been excised, is not handicapped by a potentially inferior ability, compared with radiocolloid, to image lymph nodes.
Collapse
|
42
|
Wunderlich G, Grüning T, Paulke BR, Lieske A, Kotzerke J. 99mTc labelled model drug carriers - labeling, stability and organ distribution in rats. Nucl Med Biol 2004; 31:87-92. [PMID: 14741573 DOI: 10.1016/s0969-8051(03)00120-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The surface characteristics of intravenously administered particulate drug carriers decisively influence the protein adsorption that is regarded as a key factor for the in vivo fate of the carriers. We labeled surface-modified polymer particles with the gamma-emitting radioisotope 99mTc in order to test their properties in blood and follow their in vivo fate. The biodistribution was different in various types of polymer particles. As expected, labeled particles were found in the mononuclear phagocyte system in a large scale but markedly different biodistribution for some particles were also shown.
Collapse
|
43
|
Medina LA, Klipper R, Phillips WT, Goins B. Pharmacokinetics and biodistribution of [111In]-avidin and [99mTc]-biotin-liposomes injected in the pleural space for the targeting of mediastinal nodes. Nucl Med Biol 2004; 31:41-51. [PMID: 14741569 DOI: 10.1016/s0969-8051(03)00122-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Pharmacokinetics and mediastinal node uptake of [111In]-avidin and [99mTc]-biotin-liposomes following either intrapleural (pleural) or intraperitoneal (ip) injection were determined using scintigraphic imaging. Biodistribution results of [111In]-avidin at 44 h showed 3.3% uptake in mediastinal nodes by pleural injection vs 1.3% with ip injection. Mediastinal node accumulation with [99mTc]-biotin-liposomes was not different between injections (0.6% ip vs 0.5% pleural). This study demonstrates the potential of the pleural route as a technique for mediastinal node targeting using the avidin/biotin-liposome system.
Collapse
|
44
|
Usmani OS, Biddiscombe MF, Underwood SR, Barnes PJ. Characterization of the generation of radiolabeled monodisperse albuterol particles using the spinning-top aerosol generator. J Nucl Med 2004; 45:69-73. [PMID: 14734675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2023] Open
Abstract
UNLABELLED Inhaled radiolabeled aerosols provide invaluable information about in vivo drug deposition. Here, we report our methodology for radiolabeling and imaging monodisperse pharmacologic aerosols in order to study basic aerosol science concepts of drug delivery within the human airways. METHODS We used a spinning-top aerosol generator to produce (99m)Tc-labeled monodisperse albuterol sulfate aerosols of 1.5-, 3-, and 6- micro m mass median aerodynamic diameter. RESULTS In vitro Andersen cascade validation data showed that technetium and albuterol were coassociated on each impactor stage for all 3 aerosols, and the radiolabeling process itself did not affect their particle size distributions. Good-quality gamma-camera scintigraphic images of lung and extrathoracic deposition were obtained within an asthmatic patient. CONCLUSION We have successfully radiolabeled and imaged monodisperse albuterol aerosols within the human lungs. This novel technique provides an important tool to relate fundamental concepts of aerosol particle behavior, in vivo deposition, and therapeutic clinical response.
Collapse
|
45
|
Wawroschek F, Wengenmair H, Senekowitsch-Schmidtke R, Hamm M, Henke J, Schönberger T, Hauser A, Erhardt W, Harzmann R. Prostate lymphoscintigraphy for sentinel lymph node identification in canines: reproducibility, uptake, and biokinetics depending on different injection strategies. UROLOGICAL RESEARCH 2003; 31:152-8. [PMID: 12883878 DOI: 10.1007/s00240-003-0307-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2002] [Accepted: 02/10/2003] [Indexed: 10/26/2022]
Abstract
At present there are neither clinical nor experimental data available on the influence of technical details on the quality and reproducibility of prostate lymphoscintigraphy. Six adult fox hounds received repeated transrectal ultrasound guided intraprostatic injections of a technetium 99m labeled nanocolloid to prove the influence of different techniques of injection (one central injection in both prostate lobes vs two peripheral injections in both lobes) on tracer accumulation in sentinel lymph nodes (SLN) and other organs. The reproducibility of the favored technique was examined and in a last step it was subject to scrutiny following a reduction of the injected volume to 1% of the prostate volume. The number of scintigraphically visualized SLN varied between four and seven. They were located in the region of the internal and external iliac vessels, presacrally, paravesically, and directly paraprostatically. In five of six cases, the localization was reproducible both with the central application of an identical volume as well as with the volume reduced central injection. Tracer accumulation of SLNs and other organs varied enormously. We expect that with the combination of both injection techniques, even with the reduced injection volume, an optimized prostate lymphoscintigraphy will be the outcome.
Collapse
|
46
|
Wånggren K, Lundberg S, Lundberg HJ, Asard PE, Wramsby H. Radioactivity in cervical mucus after intraperitoneal deposition of Tc-99m labelled albumin particles before and after sterilisation. Eur J Obstet Gynecol Reprod Biol 2003; 108:203-8. [PMID: 12781412 DOI: 10.1016/s0301-2115(02)00463-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To study the transport of radiolabelled albumin particles from the pouch of Douglas to cervical mucus. STUDY DESIGN A prospective randomised study, including 10 healthy women, undergoing laparoscopic sterilization. A solution of human serum albumin particles, labelled with Technetium 99(m) (Tc-99(m)) was injected into the pouch of Douglas, either before or after sterilisation. RESULTS Gamma camera images showed gradual spread to the entire peritoneal cavity. Blood samples, showed increasing levels of radioactivity. Measurement of radioactivity in cervical mucus showed significant activity both in women sterilized before and after the deposition. CONCLUSION The study showed evidence of transport of radioactivity from the pouch of Douglas to cervical mucus. The transport seemed to consist of free activity since no radionuclide labelled particles could be detected in cervical mucus. The transport was probably haematogenous or lymphatic and not intraluminal through the fallopian tube. Further studies utilizing particles comparable in size to fertilized ova are required to design methods for evaluating the transport from the fallopian tube to the uterine cavity.
Collapse
|
47
|
Devadason SG, Huang T, Walker S, Troedson R, Le Souëf PN. Distribution of technetium-99m-labelled QVAR delivered using an Autohaler device in children. Eur Respir J 2003; 21:1007-11. [PMID: 12797496 DOI: 10.1183/09031936.03.00087803] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
QVAR, an extrafine hydrofluoroalkane/beclomethasone dipropionate formulation, has been shown to double lung deposition in adults. The aim of the present study was to assess the total body deposition and distribution of technetium-99m-labelled (99mTc) QVAR in children after inhalation via an Autohaler. Sixteen male asthmatic children (5-14 yrs) inhaled labelled drug (<4 MBq 99mTc; 100 microg beclomethasone dipropionate) via an Autohaler within 30 min after salbutamol (200 microg) administration. Simultaneous anterior and posterior planar scintigraphic scans (120 s acquisition time) were collected after inhalation of labelled drug. Mean+/-SD lung deposition of labelled drug (attenuation-corrected; percentage of ex-actuator dose) was 36.9+/-9.2, 46.5+/-11.6 and 54.1+/-10.7% in children aged 5-7, 8-10 and 11-14 yrs, respectively. Combined oropharyngeal and gastrointestinal deposition was 59.7+/-8.2, 48.9+/-12.3 and 40.3+/-11.8%. Lung deposition positively correlated with the forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Gastrointestinal dose negatively correlated with the FEV1, FVC, height and age. In older children (11-14 yrs), lung deposition was almost identical to that reported in adults using QVAR. In children aged 5-10 yrs, lung deposition using QVAR was greater than the levels measured using other commercial aerosol delivery systems. Oropharygeal and gastrointestinal deposition was inversely related to age.
Collapse
|
48
|
Kalantarov KD, Segal AS, Nosovitskiĭ PB, Zhilenko VV. [Method of penile scintigraphy]. MEDITSINSKAIA TEKHNIKA 2003:19-20. [PMID: 12924216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
A method of phalloscintigraphy, based on the gamma camera and computerized data processing, is offered. The results of examination of patients are described.
Collapse
|
49
|
Tsoukalas C, Pirmettis I, Patsis G, Pelecanou M, Bodo K, Raptopoulou CP, Terzis A, Papadopoulos M, Chiotellis E. Novel oxorhenium and oxotechnetium MO(NS)(S)2 complexes in the development of 5-HT1A receptor imaging agents. J Inorg Biochem 2003; 93:213-20. [PMID: 12576284 DOI: 10.1016/s0162-0134(02)00574-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The [NS][S](2) mixed-ligand system was applied to synthesize oxorhenium and oxotechnetium complexes of the general formula MO(o-CH(3)OC(6)H(4)N(CH(2)CH(2))(2)NCH(2)CH(2)S)(p-CH(3)C(6)H(4)S)(2) (M=Re in 1, M=(99)Tc in 2, and M=(99m)Tc in 3). The bidentate [NS] ligand includes the 1-(2-methoxyphenyl)piperazine moiety which is a fragment of the true 5-HT(1A) antagonist WAY 100635. The oxorhenium complex 1 was prepared by a ligand exchange reaction using ReOCl(3)(PPh(3))(2) as precursor while [Bu(4)N][(99)TcOCl(4)] and (99)Tc-gluconate were used as precursors in the synthesis of the oxotechnetium-99 complex 2. Both complexes were characterized by elemental analysis and spectroscopic methods. Crystallographic analysis of 1 showed that the rhenium coordination geometry is trigonal bipyramidal. The basal plane of the trigonal bipyramid is defined by the oxo group and two sulphur atoms, one belonging to the [NS] ligand and the other to an aromatic thiol, while the apical positions are occupied by the nitrogen of the [NS] ligand and the sulphur of the second aromatic thiol. The oxotechnetium-99 complex 2 has almost identical unit cell parameters to those of the oxorhenium complex 1 indicating, in combination with the other analytical data, that the complexes are isostructural. The binding affinity of the oxorhenium complex 1 for the 5-HT(1A) receptor subtype was determined in rat brain hippocampal preparations (IC(50)=106 nM). The oxotechnetium-99m complex 3 was prepared by a ligand exchange reaction using (99m)Tc-glucoheptonate as the precursor. Its structure was established by comparative HPLC studies using the oxotechnetium-99 complex 2 as a reference. Complex 3 was administered by intravenous injection in rats. At 2 min post injection, 0.153% of the injected dose per gram of tissue was measured in rat brain.
Collapse
|
50
|
Berthol D, Feidt C, Brun Bellut J. Effect of low continuous 99Tc intake on its absorption and metabolism in young rats. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2003; 67:169-180. [PMID: 12691716 DOI: 10.1016/s0265-931x(02)00055-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A continuous daily oral dose of (99)TcO(4)(-) (5 Bq g(-1) day(-1)) was given to young rats for 56 days. In one group the intake was continued for 98 days, while in the other the intake was stopped to facilitate the determination of biological half lives in different organs and tissues. The absorbed fraction of (99)Tc increased from 0.7 to 0.9 during the experimental period (m=0.85 sigma=0.02). The whole body retained fraction (m=0.15 sigma=0.05) indicated a storage in the tissues. The liver and kidneys showed increasing concentrations of (99)Tc until a plateau was reached after 6 and 9 weeks, then a rapid decline after the intake was stopped (half life of 6 and 5 days respectively). In hair and thyroid tissue, the accumulation of (99)Tc increased linearly then declined very slowly after the intake was stopped and did not reach a plateau during the experiment. No significant amounts of (99)Tc were detected in the muscular tissues or in the walls of the digestive tract. After the contamination period, urinary and fecal excretions fell off very quickly (1 week), but significant, though low, quantities of urinary and fecal excretions were still observed 6 weeks after stopping intake.
Collapse
|